INSTRUCTION MANUAL
3 CCD CAMERA
For Customer Use
Enter below the Serial # which is located on the bottom of the cabinet. Retain this information for future reference.
Model #:
Serial #:
FCC NOTICE
This equipment has been tested and found to comply with the limits for a Class A digital device, pursu- ant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
This Class A digital apparatus complies with Canadian
Cet appareil num??rique de la classe A est comforme ?? la norme
Following information is only for
The use of the symbol indicates that this product may not be treated as household waste. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. For more detailed information about the takeback and recycling of this product, please contact your supplier where you purchased the product or consult.
SAFETY PRECAUTIONS
Safety icons
This manual contains safety instructions that must be observed in order to avoid potential hazards that could result in personal injuries, damage to your equipment, or loss of data.
These safety cautions have been classified according to the seriousness of the risk, and the icons highlight these instructions as follows:
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.
Indicates a potentially hazardous situation which, if not avoided, may result in property damage.
Stop operation immediately when any abnormality or defect occurs.
Use during an abnormal condition; such as emitting smoke, burning odors, dam- age from dropping invasion of foreign objects, etc. may cause fire and/or electric shock. Immediately stop the power source and contact your dealer.
Avoid installing in a shower room or a bathroom.
This may cause fire and/or electric shock.
Do not operate in places with possibility of becoming wet.
This may cause fire and/or electric shock.
Do not repair, disassemble and/or modify by yourself.
This may cause fire and/or electric shock. Be always sure to contact your dealer for internal repair, check and cleaning of the product.
Use the specified power supply.
Otherwise, a fire or an electric shock may occur.
Don???t place things or materials on the unit.
Ingress of foreign materials such as metallic objects and/or liquids into the prod- uct may cause a fire or an electric shock.
Do not put the product in an unstable, slanting and/or vibrated place.
Drop and/or fall of the product may cause serious injury.
Do not touch the product and/or any connection cables during a thunder- storm.
This might cause electric shock.
2
Note the following instructions when installing.
???Do not cover the product by any material.
???Do not put the product on an Inflammable material such as carpet or blanket.
???Do not put the product in a narrow space, since the heat generated from the product may be difficult to emanate.
If you do not follow the above, the heat generated by the product may cause fire.
Do not put the product in direct sunshine and/or high temperature.
The temperature inside the product may cause fire.
Avoid setting in humid, smoky, vaporized or dusty places.
This may cause fire and/or electric shock.
Do not point the lens directly at the sun and/or intensive light such as di- rect sunlight, etc.
Focusing of the light may cause injury of eye and/or fire.
Ask your dealer to perform a periodical check and internal cleaning (approx. once every five years).
Dust inside the product may cause fire and/or trouble. For check and cleaning cost, please consult your dealer.
Disclaimer
We disclaim any responsibility and shall be held harmless for any damages or losses incurred by the user in any of the following cases:
1.Fire, earthquake or any other act of God; acts by third parties; misuse by the user, whether intentional or accidental; use under extreme operating conditions.
2.Malfunction or
3.Incorrect use not in compliance with instructions in this instruction manual.
4.Malfunctions resulting from misconnection to other equipment.
5.Repairs or modifications made by the user or caused to be made by the user and carried out by an unauthorized third party.
6.Notwithstanding the foregoing, Toshiba???s liabilities shall not, in any circumstances, exceed the purchase price of the product.
Limitation of Usage
The product is not designed for any ???critical applications.??? ???Critical applications??? means life support systems, exhaust or smoke extraction applications, medical applications, commercial aviation, mass transit applications, military applications, homeland security applications, nuclear facilities or sys- tems or any other applications where product failure could lead to injury to persons or less of life or catastrophic property damage. Accordingly, [Toshiba/TAIS] disclaims any and all liability arising out of the use of the product in any critical applications.
Protection of Personal Information
Images taken by the camera that reveal the likeness of an individual person may be considered personal information. To disclose, exhibit or transmit those images over the internet or otherwise, consent of the person may be required.
3
Copyright and Right of Portrait
There may be a conflict with the Copyright Law and other laws when a customer uses, displays, distributes, or exhibits an image picked up by the camera without permission from the copyright holder. Please also note that transfer of an image or file covered by copyright is restricted to use within the scope permitted by the Copyright Law.
TABLE OF CONTENTS
4
This product is 3CCD color camera with digital video output.
1. CAUTIONS ON USE AND INSTALLATION
5
3. NAMES AND FUNCTIONS
6
4.CONNECTION
4.1 Standard Connection
Lens (not included)
4. 2 Cautions on Connection
???When connecting the camera cables, unplug the power source of the camera and the other equipment connected.
???We suggest using a C mount lens made for a 3CCD camera.
When using another lens, the best camera performance of this camera may not be obtained.
(For example, low resolution may occur, focus may be lost through the range of a zoom lens, and flare, ghost or shading may occur)
Furthermore, in order to avoid damaging the mounting portion of the camera head, use a lens which has projection dimension from the mounting base of less than 0.157"(4mm).
???For DC power supply connecting to DC IN 12V terminal, use UL listed and/or CSA approved ungrounding type AC adaptor with the specifications described below.
???Use the standard cable for Camera Link.
4.3 Connector Pin Assignments
Co. Ltd) or equivalent.
7
5. OPERATION
1Refer to the item " 4. CONNECTION", connect each equipment correctly.
2Turn on the connected equipment and the power source of the camera.
3Point the lens at the object, operate the lens iris adjustment, focus adjustment, etc..
4Refer to the item "5.1 White Balance", operate the adjustment.
5Refer to the items "7. MODE SETTING BY ON SCREEN DISPLAY", select the necessary items.
5. 1 White Balance
For the white balance adjustment for this unit, AWB (Automatic White Balance) and MANU (Manual white balance) adjustments are provided. To select the desired mode, refer to the items "7.2 (3) WHT BAL (White balance)" and "7. MODE SETTING BY ON SCREEN DISPLAY".
1AWB (Automatic white balance)
???Set the MODE to AWB on the WHT BAL menu.
Perform the C.TEMP (color temperature conversion) setting, if necessary. (Refer to the item "7.2 (3) WHT BAL (White balance)".)
3200K : Appropriate for indoor shooting.
5600K : Appropriate for outdoor shooting.
???If the index menu/menu is displayed, press the [DISP] button to disable the character display on the menu.
???Shoot a known white object that fills the screen and push [DATA UP] button for approx. 1 second.
???The character AWB blinks on the screen when the AWB starts.
???The character AWB stops blinking when the AWB finishes, and the result is displayed for approx. 1 second.
8
2MANU (Manual white balance)
???Set the MODE to MANU on the WHT BAL menu. (Refer to the item "7.2 (3) WHT BAL (white balance)".)
???Shoot a known white object, adjust the white balance adjusting the levels of R GAIN and B GAIN on the menu, confirming with a monitor etc.
(Refer to the item "7.2 (3) (3.2) Changing each setting in MANU (Manual) mode".)
9
6. ITEMS CONTROLLED BY USING ON SCREEN DISPLAY
10
7. MODE SETTING BY ON SCREEN DISPLAY
Various settings can be controlled on the unit by using the on screen menu displayed on the monitor. The contents once set are memorized even if the power source is turned off, so it is unnecessary to set again when using the unit next time. When the setting is performed, select the menu of the item to be set.
7. 1 Using the Menus
When the power is turned on, the normal screen showing only the video signal appears. Change the output to each screen (video signal output, Index menu, and menus) by using the [DISP], [PAGE], [MENU UP], and [MENU DOWN] buttons.
*A menu is selected when pushing the [PAGE] button after moving the "???" on the screen by the [MENU UP], [MENU DOWN] button while the Index menu is displayed.
E. TRG 1P SNR
E. TRG 1P SR
E. TRG
PW SNR
E. TRG
PW SR
11
7. 2 Menus
???Select the menu to change the setting by referring the item "7.1 Using the Menus".)
???When the [MENU UP], [MENU DOWN] buttons are pushed, the "???" on the screen moves up and down. Move the "???" to the item to change.
Note:
When performing the mode setting in the menu display while selecting ON in "PART" (refer to page 28) and E.TRG in "MODE", the display shows normal mode and then the camera returns the setting mode.
( 1 ) SHUTTER (Electronic shutter)
The electronic shutter has three modes; MANU (Manual), SS (Synchro. Scan), E.TRG (External trigger).
Set the "???" to "MODE" and push [DATA UP], [DATA DOWN] button to select the desired mode among "MANU", "SS", "E.TRG".
SS: Shutter speed can be set by the double horizontal scanning time (2H) unit or by the frame unit.
???1P SNR (1 Pulse Sync Non Reset)
The charge begins to accumulate after the trigger pulse is received, and 1 frame images are output according to the internal vertical sync signal timing. The exposure/accumula- tion time can be set from 0.01 to 50 ms. The trigger signal timing can be set to either the rising or falling edge.
???1P SR (1 Pulse Sync Reset)
The charge begins to accumulate after the trigger pulse is received. Upon completion of accumulation the vertical sync signal is reset and 1 frame images are output. The exposure/accumulation time can be set from 0.01 to 50 ms. The trigger signal timing can be set to either the rising or falling edge.
???PW SNR (Pulse width trigger Sync Non Reset)
The charge begins to accumulate after the trigger pulse is received, and 1 frame images are output according to the internal vertical sync signal timing. This is the mode to set the exposure period by the pulse width of the trigger. The trigger signal polarity can be set to either the positive or negative polarity.
???PW SR (Pulse width trigger Sync Reset)
The charge begins to accumulate after the trigger pulse is received. Upon completion of accumulation the vertical sync signal is reset and 1 frame images are output. This is the mode to set the exposure period by the pulse width of the trigger. The trigger signal polarity can be set to either the positive or negative polarity.
12
(1. 1) Changing each setting in MANU mode
(a) Changing the shutter speed
1Set the "???" to MANU by pushing [MENU UP], [MENU DOWN] buttons.
2Set the shutter speed by pushing [DATA UP], [DATA DOWN] buttons.
(b) Partial scanning setting
1Set the "???" to PART by pushing [MENU UP], [MENU DOWN] buttons.
2Select either OFF/30fps/40fps/E.30fps/E.40fps by pushing [DATA UP], [DATA DOWN] buttons.
13
(1. 2) Changing each setting in SS (synchro. scan) mode
<MODE = SS>
(a) Changing the shutter speed setting
1Set the "???" to SS by pushing [MENU UP], [MENU DOWN] buttons.
2Select the shutter speed by pushing [DATA UP], [DATA DOWN] buttons.
(b) Partial scanning setting
1Set the "???" to PART by pushing [MENU UP], [MENU DOWN] buttons.
2Select either OFF/30fps/40fps/E.30fps/E.40fps by pushing [DATA UP], [DATA DOWN] buttons.
Note:
The slow shutter speed may increase the fixed pattern noise and/or the white pixels. This is a charac- teristic of CCD, and is not a symptom of malfunction.
14
(1. 3) Changing each setting in E.TRG mode
The E.TRG has four modes; 1P SNR, 1P SR, PW SNR, PW SR.
First set the "???" to MODE and select E. TRG, then set the "???" to E.TRG and select the desired E.TRG mode.
(1. 3. 1) Changing each setting in 1P SNR mode
Move up down By pushing
MENU UP, DOWN
Set by pushing
DATA UP, DOWN
(a) Changing the polarity of inputting trigger pulse setting
1Set the "???" to TRG.P by pushing [MENU UP], [MENU DOWN] buttons.
2Select either , by pushing [DATA UP], [DATA DOWN] buttons.
(b) Changing 1P SNR exposure time setting
1Set the "???" to EXP. by pushing [MENU UP], [MENU DOWN] buttons.
2Set the exposure time by pushing [DATA UP], [DATA DOWN] buttons.
(c) Changing the partial scanning setting
1Set the "???" to PART by pushing [MENU UP], [MENU DOWN] buttons.
2Select either OFF/30fps/40fps/E.30fps/E.40fps by pushing [DATA UP], [DATA DOWN] buttons.
15
(1. 3. 2) Changing each setting in 1P SR mode
???Exposure time setting at 1P SNR and 1P SR
0.01ms0.02 ms0.4 ms 1 ms20 ms50 ms
(a) Changing the polarity of inputting trigger pulse setting
1Set the "???" to TRG.P by pushing [MENU UP], [MENU DOWN] buttons.
2Select either , by pushing [DATA UP], [DATA DOWN] buttons.
(b) Changing 1P SR exposure time setting
1Set the "???" to EXP. by pushing [MENU UP], [MENU DOWN] buttons.
2Set the exposure time by pushing [DATA UP], [DATA DOWN] buttons.
(c) Changing the partial scanning setting
1Set the "???" to PART by pushing [MENU UP], [MENU DOWN] buttons.
2Select either OFF/30fps/40fps/E.30fps/E.40fps by pushing [DATA UP], [DATA DOWN] buttons.
16
(1. 3. 3) Changing each setting in PW SNR mode
<MODE = E.TRG E.TRG = PW SNR>
(a) Changing the polarity of inputting trigger pulse setting
1Set the "???" to TRG.P by pushing [MENU UP], [MENU DOWN] buttons.
2Select either , by pushing [DATA UP], [DATA DOWN] buttons.
(b) Changing the partial scanning setting
1Set the "???" to PART by pushing [MENU UP], [MENU DOWN] buttons.
2Select either OFF/30fps/40fps/E.30fps/E.40fps by pushing [DATA UP], [DATA DOWN] buttons.
Note:
The longer the storage time with extended exposures, the more visible certain characteristics of CCD cameras become: fixed pattern noise, white pixels, etc.
17
(1. 3. 4) Changing each setting in PW SR mode
(a) Changing the polarity of inputting trigger pulse setting
1Set the "???" to TRG.P by pushing [MENU UP], [MENU DOWN] buttons.
2Select either , by pushing [DATA UP], [DATA DOWN] buttons.
Note:
The longer the storage time with extended exposures, the more visible certain characteristics of CCD cameras become: fixed pattern noise, white pixels, etc.
18
( 2 ) GAIN (Video gain)
When the image is dark even if the lens iris is open, change the gain (video gain) to get the proper video level. For the gain adjustment of the unit, MANU (Manual) and OFF (0dB) modes are provided.
1MANU (Manual gain)
Gain adjustment is performed on the GAIN menu. The adjustment range is from 0dB to 18dB in 1dB steps.
2OFF
Gain is fixed at 0dB.
Set the "???" to MODE, push the [DATA UP], [DATA DOWN], and select mode among MANU, OFF.
(2. 1) Changing each setting in GAIN
(a) Changing the gain in MANU mode
1Set the "???" to MANU by pushing [MENU UP], [MENU DOWN] buttons.
2Set the manual gain by pushing [DATA UP], [DATA DOWN] buttons.
19
( 3 ) WHT BAL (White balance)
WHT BAL has two modes; AWB, MANU.
Set the "???" to MODE, push the [DATA UP], [DATA DOWN], and select mode among AWB, MANU.
(3. 1) Changing each setting in AWB (Automatic White Balance) mode
(a) Changing color temperature setting
1Set the "???" to C.TEMP by pushing [MENU UP], [MENU DOWN] buttons.
2Select either 3200 or 5600 by pushing [DATA UP], [DATA DOWN] buttons.
(3. 2) Changing each setting in MANU (Manual) mode
Move up down By pushing
MENU UP, DOWN
Set by pushing
DATA UP, DOWN
(a) Changing the red gain
1Set the "???" to R GAIN by pushing [MENU UP], [MENU DOWN] buttons.
2Set the red gain by pushing [DATA UP], [DATA DOWN] buttons.
(b) Changing the blue gain
1Set the "???" to B GAIN by pushing [MENU UP], [MENU DOWN] buttons.
2Set the blue gain by pushing [DATA UP], [DATA DOWN] buttons.
20
( 4 ) PROCESS
???Gamma Correction (GAMMA)
Select either OFF or ON of Gamma Correction.
???Master Pedestal (M. PED)
Set the Pedestal level of each RGB.
???R Pedestal (R. PED)
Set the Pedestal level of Red.
???B Pedestal (B. PED)
Set the Pedestal level of Blue.
???Shading Correction (SHAD.)
Due to the lens used or the environmental condition, vertical color shading may occur at the top and bottom of the screen. In this case, the shading correction can decrease the color shading. For the shading correction of the unit, MANU (Manual shading correction) and OFF (no shading correction) modes are provided.
1MANU (Manual Shading)
Adjust the correction amount on the PROCESS menu by confirming with a monitor or a waveform monitor.
2OFF
The status is no shading correction.
*The shading correction is effective when the lens iris or zoom ratio is fixed. Use the unit with SHAD. OFF for variable lens conditions.
Move up down By pushing
MENU UP, DOWN
Set by pushing
DATA UP, DOWN
??? Manual shading adjustment
(4. 1) Changing gamma correction
1 Set the "???" to GAMMA by pushing [MENU UP], [MENU DOWN] buttons.
2 Set the gamma correction by pushing [DATA UP], [DATA DOWN] buttons.
(4. 2) Changing master pedestal
1 Set the "???" to M. PED by pushing [MENU UP], [MENU DOWN] buttons.
2 Set the master pedestal by pushing [DATA UP], [DATA DOWN] buttons.
(4. 3) Changing R pedestal
1 Set the "???" to R. PED by pushing [MENU UP], [MENU DOWN] buttons.
2 Set the R pedestal by pushing [DATA UP], [DATA DOWN] buttons.
(4. 4) Changing B pedestal
1 Set the "???" to B. PED by pushing [MENU UP], [MENU DOWN] buttons.
(4. 5) Changing the shading correction mode
1Set the "???" to SHAD. by pushing [MENU UP], [MENU DOWN] buttons.
2Set the SHAD. by pushing [DATA UP], [DATA DOWN] buttons.
Note: The alignment value for shading is fixed to "0" when selecting SHAD. OFF. MANU is not dis- played in the menu.
(4. 6) Changing the manual shading correction setting
1Set the "???" to MANU by pushing [MENU UP], [MENU DOWN] buttons.
2Set the MANUAL SHADING by pushing [DATA UP], [DATA DOWN] buttons.
( 5 ) OPTION
(5. 1) Changing serial communication baud rate
1Set the "???" to BAUD RATE by pushing [MENU UP], [MENU DOWN] buttons.
2Select either 9600 or 19200 by pushing [DATA UP], [DATA DOWN] buttons.
Move up down By pushing
MENU UP, DOWN
Set by pushing
DATA UP, DOWN
( 6 ) Setting to factory setting status
All the settings can be returned to the factory default status (preset status).
(1)If characters are displayed on the screen, press the [DISP] button to disable the character display.
(2)Push [MENU DOWN] and [DATA DOWN] buttons simultaneously for approx. 1 second.
(3)The preset operation starts. When the preset operation finishes, the character PRESET OK is displayed for approx. 1 second.
22
7. 3 Synchro. Scan Operation
The shutter speed can be set by the double horizontal scanning period (2H) or by the frame.
( 1 ) Setting by 2H
2H/1592H ~ 1590H/1592H (2H/1060H ~ 1058H/1060H at 30fps and E.30fps of Partial Scanning, 2H/774H ~ 772H/774H at 40fps and E.40fps of Partial Scanning) stands for the setting by the 2H and the shutter speed can be set by the 2H (62.8 ???s).
( 2 ) Setting by the frame
2FRM to 512FRM stand for the setting (long period exposure) by the frame.
The video signal stored during the frame period set is output as 1 frame video image at a frame interval specified.
(Internal VD)
(video interval image)
FVAL
LVAL,
DAVL
(4FRM setting)
23
7. 4 E. TRG (External trigger)
Charge begins to accumulate after the trigger input to CC1 of the DIGITAL terminal, and 1 frame images are output. There are four modes: 1P SNR, 1P SR, PW SNR, PW SR.
( 1 ) 1P SNR (1 Pulse Trigger Sync Non Reset)
Charge begins to accumulate after the trigger input to CC1 of the DIGITAL terminal, and 1 frame images are output.
(1. 1) 1 Pulse Trigger
Negative polarity mode
Trigger*1
Positive polarity mode
About 1 ???s
(Internal VD)*3
RGB data (video interval image)
FVAL
LVAL,
DVAL
58H (Partial scanning OFF)
56H (Partial scanning 30fps)
78H (Partial scanning 40fps)
*1: Externally input signal
*2: Exposure time is determined by the setting of "7. 2 (1.3) Changing each setting in E.TRG mode".
*3: Video is output at the falling edge of the internal VD following completion of the exposure period.
The video and FVAL/LVAL/DVAL have a paired relationship.
Note:
When the next trigger is input before completion of the output of the video corresponding to the trig- ger, there will be an effect on the video.
24
( 2 ) 1P SR (1 Pulse Trigger Sync Reset)
Charge begins to accumulate after the trigger input to CC1 of the DIGITAL terminal, the vertical sync signal is reset and frame images are output.
(2. 1) 1 Pulse Trigger
Negative polarity mode
Trigger*1
Positive polarity mode
About 1 ???s
Exposure period*2
Exposure completion
0 to 2H*3
(Internal VD)
RGB data (video interval image)
FVAL
LVAL,
DVAL
58H (Partial scanning OFF)
56H (Partial scanning 30fps)
78H (Partial scanning 40fps)
*1: Externally input signal
*2: Exposure time is determined by the setting of "7. 2 (1.3) Changing each setting in E.TRG mode".
*3: VD is generated after 0 to 2H following the completion of the exposure period and the video is synchro- nized to this and output.
Note:
When the next trigger is input before completion of the output of the video corresponding to the trig- ger, there will be an effect on the video.
25
( 3 ) PW SNR (Pulse width trigger
The trigger input to CC1 of the DIGITAL terminal develops 1 frame images.
(3. 1) Pulse Width Trigger
Negative polarity mode
Trigger*1
Positive polarity mode
(Internal VD)
RGB data (video interval image)
FVAL
LVAL,
DVAL
(Valid trigger pulse width is 2 ???s or greater for external trigger shutter operation.)
*3: Video is output at the falling edge of the internal VD following completion of the exposure period. The video and FVAL/LVAL/DVAL have a paired relationship.
Note:
When the next trigger is input before completion of the output of the video corresponding to the trig- ger, there will be an effect on the video.
26
( 4 ) PW SR (Pulse width trigger
The trigger input to the CC1 of the DIGITAL terminal develops 1 frame images.
(4. 1) 1 Pulse Width Trigger
Negative polarity mode
Trigger*1
Positive polarity mode
(Internal VD)*3
RGB data (video interval image)
FVAL
LVAL,
DVAL
58H (Partial scanning OFF)
56H (Partial scanning 30fps)
78H (Partial scanning 40fps)
*1: Externally input signal
*2: Exposure time = Trigger pulse width + 6 ???s
(Valid trigger pulse width is 2 ???s or greater for external trigger shutter operation.)
*3: VD is generated after 0 to 2H following the completion of the exposure period and the video is synchro- nized to this and output.
Note:
When the next trigger is input before completion of the output of the video corresponding to the trig- ger, there will be an effect on the video.
27
7. 5 Partial Read
( 1 ) Partial Scanning OFF (All pixels scanning)
In this mode, all pixels independent signal from the DIGITAL connector is output each 1/20 second (Line order output).
Video interval image
1/20s (1592H)
( 2 ) Partial Scanning ON
In this mode, the pixel signal of the vertical center portion from the DIGITAL connector is output.
In the E.30fps or E.40fps mode, the partial scanning and the all pixels scanning can be switched by the DIGITAL terminal (CC2: partial scanning control signal).
Video interval image
1/30s (1060H): When 30fps is selected
1/40s (774H): When 40fps is selected
( 3 ) When Partial Scanning Mode is ON
(Internal VD)
FVAL
LVAL,
DVAL
RGB data (video interval image)
28
8. OUTPUT WAVEFORM TIMING CHART
( 1 ) Horizontal Output Waveform Timing Chart
One horizontal scan interval 2540 clk
(31.4 ???s)
LVAL???
DVAL
RGB data
Pixel
Clock
CLK=12.36nsec
(80.8736MHz)
( 2 ) Vertical Output Waveform Timing Chart
FVAL
LVAL???
DVAL
(CCD READOUT)
RGB data
1592H
29
9. SPECIFICATIONS
The designs and specifications are subject to change without notice.
30
10. EXTERNAL APPEARANCE DIAGRAM
44
[1.73]
Unit : mm [inch]
* inch=mm/25.4
11. BEFORE MAKING A SERVICE CALL
31
LIMITED WARRANTY
TOSHIBA CCD CAMERA
The Imaging Systems Division of Toshiba America Information Systems, Inc. ("ISD") makes the following limited warranties. These limited warranties extend to the Original
Limited One (1) Year Warranty of Labor and Parts
ISD warrants this product and parts against defects in material or workmanship for a period of one year from the date of original retail purchase by the
[1]Verify operation of the unit by checking the instruction manual
[2]If there is a defect in material or workmanship, contact an Authorized Service Provider within 30 days after the product fails to comply with specifications.
[3]Arrange for delivery of the product to the ISD authorized service center. Products must be insured and securely packed, preferably in the original shipping carton. A letter explaining the defect and a copy of the bill of sale or other proof of purchase must be enclosed with a complete return street address and daytime telephone number. Charges for transportation and insurance must be prepaid by the
Questions? If you have any questions, please check the Toshiba Imaging Systems Division Web site as follows:
Website: http://www.toshiba.com/taisisd/indmed
Your Responsibility, warranties are subject to the following conditions:
[1]You must retain the bill of sale or provide other proof of purchase.
[2]You must schedule service within thirty days after you discover a defective product or part.
[3]All warranty servicing of this product must be made by a Toshiba ISD Authorized Service Provider.
[4]The warranty extends to defects in material or workmanship as limited above, and not to any products or parts that have been lost or discarded by user. The warranty does not cover damage caused by misuse, accident, improper installation, improper maintenance, or use in violation of instructions furnished by ISD. The warranty does not extend to units which have been altered or modified without authorization of ISD, or to damage to products or parts thereof which have had the serial number removed, altered defaced or rendered illegible.
ALL WARRANTIES IMPLIED BY STATE LAW, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABIL-
ITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSLY LIMITED TO THE DURATION OF THE LIMITED WARRANTIES SET FORTH ABOVE. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply. WITH THE EXCEPTION OF ANY WARRANTIES IM-
PLIED BY STATE LAW AS HEREBY LIMITED, THE FOREGOING EXPRESS WARRANTY IS EXCLUSIVE AND
IN LIEU OF ALL OTHER WITH RESPECT TO THE REPAIR OR REPLACEMENT OF ANY PRODUCTS OR PARTS. IN NO EVENT SHALL ISD BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES. Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limita- tion may not apply.
No person, agent, distributor, dealer, service station or company is authorized to change, modify or extend the terms of these warranties in any manner whatsoever. The time within which an action must be com- menced to enforce any obligation of ISD arising under this warranty or under any statute, or law of the United States or any state thereof, is hereby limited to one year from the date you discover or should have discovered, the defect. This limitation does not apply to implied warranties arising under state law. Some states do not permit limitation of the time within which you may bring an action beyond the limits provided by state law so the above provision may not apply to user. This warranty gives the user specific legal rights, and user may also have other rights, which may vary from state to state.
TOSHIBA AMERICA INFORMATION SYSTEMS, INC.
Imaging Systems Division