1551 E 11th Street, Loveland, CO 80537 ???
INSTRUCTIONS
Introduction
Congratulations on the purchase of your new electronic scoreboard. Your scoreboard is state of the art and designed
along with detailed information regarding your particular model. If further information is required please contact your CDS sales representative at
Service and Customer Information
In the event service is required for your scoreboard or if you wish to order replacement parts please contact your CDS sales representative at
To aid in your discussions, we suggest that you record the following information for reference:
MODEL NUMBER: ___________________________________________________________
INSTALLATION DATE: _______________________________________________________
CDS SALES
REPRESENTATIVE: ___________________________________________________________
CONTACT
INFORMATION: _______________________________________________________________
CONTACT
PRODUCT
SERIAL NUMBERS: ____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
1551 E 11th Street, Loveland, CO 80537 ???
INSTRUCTIONS
Indoor Scoreboards
Your scoreboard will require a 120 VAC, 60 Hz, grounded receptacle located within 5 feet of the
NOTE: On scoreboards with the cULus mark, the scoreboard does not come equipped with a power cord as these units must be permanently wired in.
Data cabling for the scoreboard is available in standard lengths (connectors factory installed), or as a kit for custom lengths (connectors installed on site). See the DATA CABLING section for more information.
Wall mounting is the preferred method of installation. When determining the installation location, ensure -
shipping. Remove and
type of fasteners selected should be suitable for the type of wall construction and have su???cient capacity to support the scoreboard. CDS recommends using 3/8??? fasteners. Detailed information regarding mount- ing locations and fasteners recommendations for your scoreboard model is provided in the documentation attached.
1551 E 11th Street, Loveland, CO 80537 ???
11th E 1551
GENERIC INDOOR INSTALLATION
D
4 POS. MALE CONNECTOR
D
Street,
PIN G
4 POS. FEMALE CONNECTOR
Loveland,
PIN 1 - V+ (DC CONTROLLER ONLY)
GROUNDED ELECTRICAL CORD
PIN 2 - COM (DC CONTROLLER ONLY) APPROX. LENGTH - 5 FEETPIN 3 - WHITE (RS +)
PIN 4
PIN 3
PIN 1
PIN 2
PIN G
PIN 1 - V+ (DC CONTROLLER ONLY)
PIN 2 - COM (DC CONTROLLER ONLY)
CO
PIN 4 - BLACK (RS
PIN G - SHIELD
SOLDER CUP VIEW
PIN 1
PIN 2
PIN 4
PIN 3
PIN 3 - WHITE (RS +) PIN 4 - BLACK (RS
PIN G - NO CONNECTION
C
SOLDER CUP VIEW
7 8 9
4 5 6
1 2 3
CLEAR 0 ENTER
C
com.coloradotime.www ???
B
SCOREBOARD
ISC85X CONTROLLER
B
CONTROLLER WIRING:
CONNECT CONTROLLER DATA WIRE AS PER
PIN OUTS DETAILED ABOVE.
DC CONTROLLER RECEIVES POWER FROM SCOREBOARD
AC AND RF CONTROLLERS WILL REQUIRE AN 120VAC
RECEPTACLE NEAR CONTROLLER LOCATION.
INSTRUCTIONS
INSTRUCTIONS
Installation
Outdoor Scoreboards
Your scoreboard will require a 120 VAC, 60 Hz, grounded electrical feed. Typically the feed will be a dedicated 20 Amp circuit. Optional 230VAC, 60Hz, is also available. Refer to the model speci???c information provided in this package for the exact current load for your scoreboard. FIGURE 2 illustrates a generic installation including a con- troller. CDS recommends using ONLY grounded metal conduit. Seek the service of a quali???ed electrician to ensure the electrical installation meets all local electrical codes. CDS assumes no responsibilities for installations done by others. Data cabling for the scoreboard is available as a kit for installation with the grounded conduit (connectors installed on site). See the DATA CABLING for more information.
Pole mounting is the preferred method of installation. Seek the service of a quali???ed contractor to ensure the struc-
CD
scoreboard is shipped with mounting brackets which will require installation prior to mounting the scoreboard. All necessary hardware required to mount the brackets to the scoreboard is provided with your new scoreboard. Lift- ing eyebolts are provided on the top of the scoreboard to facilitate lifting of the unit to its ???nal installation location.
suitable for the type of construction and have su???cient capacity to support the scoreboard. CDS recommends using ?????, grade 8 fasteners. Detailed information regarding mounting locations and fastener recommendations for your scoreboard model is provided in the documentation attached.
1551 E 11th Street, Loveland, CO 80537 ???
Loveland, Street, 11th E 1551
GENERIC OUTDOOR INSTALLATION
D
2
PIN G
D
4 POS. FEMALE CONNECTOR
PIN 1 - V+ (DC CONTROLLER ONLY)
PIN 2 - COM (DC CONTROLLER ONLY)
PIN 4PIN 3 - WHITE (RS +)
PIN 1
PIN 2
PIN 3
PIN 4 - BLACK (RS
SOLDER CUP VIEW
PIN G - NO CONNECTION
C
7 8 9
4 5 6
1 2 3
CLEAR 0 ENTER
com.coloradotime.www ???
ISC85X CONTROLLER
INSTRUCTIONS
TE
com.coloradotime.www ???
INSTRUCTIONS
:
INSTRUCTIONS
Installation
Data Cabling
Data cabling can be purchased as a
Installation Accessories
A wide range of accessories are available to you and your facility to ease installation and protect your scoreboard investment. Products such as junction boxes and connector boxes are available to provide a professional appearance to any installation. RF radios are available for both indoor and outdoor scoreboards to eliminate costly controller cabling. Safety screens are available to protect the scoreboard from accidental impact. Protective bags are available for controller storage and transport while not in use. Please contact your CDS sales representative for more infor- mation on available accessories for your scoreboard.
Model Speci???c Documentation
ment parts, and speci???c mounting details. If any further information is required please contact your CDS sales representative at
1551 E 11th Street, Loveland, CO 80537 ???
1551 E 11th Street, Loveland, CO 80537 ???
1551 E 11th Street, Loveland, CO 80537 ???
1551 E 11th Street, Loveland, CO 80537 ???
INSTRUCTIONS
ISC85X Intelligent Controller
INTRODUCTION:
The ISC85x controller comes ready to use; no setup required. All settings are
NOTE: These con???gure features, including this instruction sheet, should be kept from the standard user and only made available to the person in charge of the scoreboard system.
OPERATION:
To enter into con???gure mode on the controller:
???Turn on controller.
???Turn RUN/STOP switch to STOP position.
???Press and hold the bottom button in the ???fth column on the keypad until the con???gure menu appears (Button to the left of CLEAR). This button may be blank or may be labeled ???CONFIG??? or ???SETUP???.
???Select desired option using the numeric keypad.
OPTIONS:
1. Board Off/On:
???This blanks the entire scoreboard. This is only required on a few baseball scoreboard models, since the majority will blank on their own 15 seconds after the last communications for the controller.
2. Select Sport/Features:
???The ???rst screen selects the sport, follow on screen instructions.
MODEL 52xx SYSTEM NOTE: basketball, volley ball, and wrestling are valid selections.
MODEL 62xx SYSTEM NOTE:
Hockey is only valid selection.
1551 E 11th Street, Loveland, CO 80537 ???
INSTRUCTIONS
ISC85X Intelligent Controller
The next screen selects the features.
??????0??? indicates disabled
??????1??? indicates enabled
??????X??? means ???0??? or ???1??? will depend on the system (Contact factory if clari???cation is required.)
Follow on screen instructions to properly
NOTE: Improper settings will result in the scoreboard operating and displaying undesirably.
3. TOD
???This sets up the time of day on the clocks in the scoreboard system.
???Ensure all clocks that need to receive this setting are on and attached to the controller through the communication network.
???Follow on screen instructions to properly
4. Contrast
???This controls the brightness / contrast of the LCD on the controller.
???Follow on screen instructions to properly
5. Board Test:
???This will test the scoreboard digits.
The ???rst test, All On, turns on everything The other test, Rotate, has all digits counting from
???These tests continue until you exit from the screen and then will return to the game displays.
???Follow on screen instructions to control the tests.
6. Exit
???This exits the con???gure screens without any changes.
1551 E 11th Street, Loveland, CO 80537 ???
ISC85X Intelligent Controller
5240 Instructions
BASKETBALLISC85X
1.START/STOP the clock:
???Flip switch ON/OFF (Rocker switch on the right side of the unit.)
2.Manual HORN:
???Activate by pressing the push button switch on the right side of the unit.
3.Automatic HORN:
???Horn sounds automatically when time hits 0:00.
???Horn will sound for 1.5 seconds.
4.To set TIME:
???Press GAME TIME.
???Enter ???minutes??? on the numeric keypad. Press Enter.
???Enter ???seconds??? on the numeric keypad. Press Enter.
???When pressed at the end of the period, the last entered time will appear and the period will automatically increment.
5.To set TIME OUT/INTERMISSION timer:
???Press INT. MODE.
???Enter ???minutes??? on the numeric keypad.
Press Enter.
???Enter ???seconds??? on the numeric keypad. Press Enter.
INT. ??? To exit this mode, press INT. MODE again.
INSTRUCTIONS
6.To set PERIOD/QUARTER:
???Press PERIOD.
???Enter period on the numeric keypad. Press Enter.
7.To set SCORES:
???Press HOME SCORE or GUEST SCORE.
???Enter score on numeric keypad. Press Enter.
8.To INCREMENT SCORES:
???Press HOME SCORE or GUEST SCORE.
???Then press: +1,+2, or +3.
9.To toggle POSSESSION between HOME/GUEST:
???Press POSS.
10.To toggle between ???BONUS???: No Bonus (0); Single Bonus (1); and Double Bonus (2).
???Press HOME BONUS or GUEST BONUS.
11.To set TIME OUT
???Press HOME TIME OUT or GUEST TIME OUT.
???Toggles On or Off.
12.(Optional) To set Shot Clock:
???Press SHOT CLOCK SET.
???Enter ???shot clock??? length on the
numeric keypad. Press Enter.
???NOTE: if not using the shot clock, set the shot clock time to zero.
13.(Optional) To Reset Shot Clock:
???Press SHOT CLOCK RESET.
14.To set SHIFT TIMER (IF ENABLED):
NOTE: The SHIFT TIMER counts down from the set amount. When the SHIFT TIMER is expired a one second horn will sound, then the SHIFT TIMER will reset and start counting down again.
???Press SHIFT.
???Enter the shift time settings in minutes using the numeric keypad. Press ENTER.
???To edit the current running shift time Press SHIFT. Then SHIFT again. Enter the minutes using the numeric keypad.Press ENTER.Enter the seconds using the numeric keypad.Press ENTER.
NOTE: On power up, the shift time will be 0:00, which leaves it in an inactive mode which means no horns will sound.
1551 E 11th Street, Loveland, CO 80537 ???