SiPass standalone
ACS3110
User manual
Fire Safety & Security Products
Siemens Building Technologies
Lieferm??glichkeiten und technische ??nderungen vorbehalten.
Data and design subject to change without notice. / Supply subject to availability. ?? 2005 Copyright by
Siemens Building Technologies AG
Wir behalten uns alle Rechte an diesem Dokument und an dem in ihm dargestellten Gegenstand vor. Der Empf??nger anerkennt diese Rechte und wird dieses Dokument nicht ohne unsere vorg??ngige schriftliche Erm??chtigung ganz oder teilweise Dritten zug??nglich machen oder au??erhalb des Zweckes verwenden, zu dem es ihm ??bergeben worden ist.
We reserve all rights in this document and in the subject thereof. By acceptance of the document the recipient acknowledges these rights and undertakes not to publish the document nor the subject thereof in full or in part, nor to make them available to any third party without our prior express written authorization, nor to use it for any purpose other than for which it was delivered to him.
Basic information
1 Basic information
SiPass standalone is a complete access control system for one door and up to 500 cardholders. SiPass standalone uses 125 kHz proximity technology. For gaining access, it is sufficient to hold the badge close to the reader.
For programming purposes, an optional Remote Programmer can be used, which is simply held close to the reader the same way as a user badge. No wiring con- nection is required.
2 Access modes
SiPass standalone can operate in 2 modes:
2.1Tag types
Badge type
3 Badge type
3.1User badge
User
Can be used in ???Access??? mode only.
Special
Can be used in both, ???Access??? and ???Night lock??? mode.
3.2Master badge
Program Master
Master of masters
Add Master
Allows to introduce new badges to the systems memory
Void Master
Allows to delete (void) badges from the systems memory
Night lock master
Switches the system from access mode to night lock mode and back.
6
LED indicators
4 LED indicators
Read indication (yellow)
Open (green)
Closed (red)
Night lock (red)
Add (red)
Void (red)
Program (red)
Fig. 1 LED indicators
5 Overall
In Program Mode, after 30 seconds of inactivity, an error tone sounds, and normal operation resumes.
Security measures
6 Security measures
6.1Missing tag
For safety precautions the user is strongly advised to keep records of the ID num- bers and functions of all badges and the names of their users. In case of loss, the specific badges can be voided from memory by entering the badge number on the SiPass standalone Remote Programmer. See Appendix.
6.2Anti tamper
A tamper alarm is triggered if the unit is ripped off the wall.
6.3Anti vandal
Thanks to the proximity reading principle, the reader can be installed behind pro- tective surfaces, such as glass, plastic or marble, but not metal.
8
Wake up: Declaring the Program Master
7 Wake up: Declaring the Program Master
When powering up a SiPass standalone for the first time, one selected badge must be presented, to be declared as the Program Master. The Program Master may be regarded as a kind of master of masters; it will be instrumental in enabling all other masters and badges.
Any SiPass 125 kHz Proximity badge can be used as the Program Master. Program the corresponding master cards according to their symbols.
For security reasons, carefully guard masters, note their numbers and store them in a secure place.
9
Siemens Building Technologies
Declaring the masters
8 Declaring the masters
SiPass standalone has 3 programming modes which need to be processed before normal operation.
When going through these modes the first time, you can directly declare the re- spective masters.
Fig. 3 Declaring the master
All programming can be performed with the master cards. Note their numbers and store them in a secure place.
Be declared
CAUTION: If the presented
10
Change Program Master
9 Change Program Master
This procedure replaces the old Program Master by a new one. The old Program Master is thereby voided from the SiPass standalone memory and the new badge is declared as Program Master instead. This is helpful if e.g. an other Program Master than the normal one was added to the memory during
Present the new Program Master a further 5 times to step through the remaining steps, back to Normal mode.
Fig. 4 Change Program Master
Any new / unknown badge can be declared as new Program Master.
If change Program Master function is not desired, just present the old Program Master again the necessary number of times to get to the desired programming step.
11
Siemens Building Technologies
Add new user badge
10 Add new user badge
Badges which shall be granted access must first be stored in the SiPass stand- alone memory. The Add Master allows new badges to be added which, from then on, will be granted access. Any badge can be added, except Master badges and badges which are already in memory.
Fig. 5 Add user badge
Any SiPass badge can be added, except those that are already in memory. Keep records of the ID numbers and functions of all badges. Lost badges can be
voided from memory by number, using an optional Remote Programmer. See Appendix.
12
Void user badge
11 Void user badge
Badges which shall be denied access must first be voided from the SiPass stand- alone memory. The Void Master allows badges to be voided which, from then on, will be denied access.
Fig. 6 Void user badge
Any badge can be voided, except Master badges.
13
Siemens Building Technologies
Set Night Lock Mode
12 Set Night Lock Mode
In night lock mode, normal badges will not be granted access. Only Special User
Badges are granted access in this mode.
Night Lock Mode is switched on with the Night Lock Master
Fig. 7 Set night lock
In case of power failure, SiPass standalone will memorize the current status of the Night Lock.
Badges that are added to memory during Night Lock Mode are entered into memory as Special User Tags, to be granted access both in Night Lock Mode and in Normal Access Mode.
14
Unset Night Lock Mode
13 Unset Night Lock Mode
Only the Night Lock Master can switch Night Lock off. When presenting the Night Lock Master to unset Night Lock, access is granted at the same time.
This function is intended for persons who are authorized to enable access for oth- ers, for example to unlock an office building in the morning.
Fig. 8 Unset night lock
In case of power failure, SiPass standalone will memorize the current status of the
Night Lock.
Add Special User Badge
14 Add Special User Badge
Special User Badges are granted access both, during Night Lock and during Nor- mal Operation. Unlike the Night Lock Master, they have no effect on Night Lock status.
Special User Badges must be added by using the Add Master while SiPass stand- alone is in Night Lock mode.
Fig. 9 Add Special User Badge
Any SiPass 125 kHz badge can be added, except badges which are already in memory as Special User Badges or Master.
Special User Badges can be voided the same way as normal badges (in Void mode, regardless of the status of Night Lock).
Keep records of the ID numbers and functions of all badges. Lost tags can be voided from memory by number, using an optional Remote Programmer. See Appendix.
16
Declare Remote Programmer
15 Declare Remote Programmer
To store a Remote Programmer in the SiPass standalone memory, first show the Program Master to enter Program mode, then present the Remote Programmer while in Program mode. After this, SiPass standalone will resume its normal opera- tion.
Fig. 10 Declare remote programmer
17
Siemens Building Technologies
Void badge with a Remote Programmer
16 Void badge with a Remote Programmer
Using a Remote Programmer, badges or Remote Programmers can be voided by their number. This is useful if badges or Remote Programmers are lost, stolen or damaged beyond use. For this reason it is important to keep records of all added badges, Masters and Remote Programmers.
Fig. 11 Void badge with programmer
1Press key
2Keep key depressed
3Move Programmer through the reading range while keeping the key de- pressed
Fig. 12 Void badge
Any badge or Programmer in memory can be voided. Leading 0???s of the ID number need not be entered (004290621 can be entered as 4290621).
If the User Programmer is missing or damaged, ask the supplier to perform void- ing with his backup Programmer.
18
Appendix
17 Appendix
17.1Tag registration list
Masters
Program Master
Void Master
Add Master
Nightlock Master
Remote Programmers
Users
Issued by
Siemens Building Technologies
Fire & Security Products GmbH & Co. oHG
www.sbt.siemens.com
?? 2005 Copyright by Siemens Building Technologies AG
Data and design subject to change without notice. Supply subject to availability.
Printed in the Federal Republic of Germany on
Document no.
Edition 02.2005