The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our documentation to suit your individual needs. Fax forms for sending us your comments are included in the back of the manual. There you will also find the addresses of the relevant User Documentation Department.
Certified documentation according to DIN EN ISO 9001:2000
To ensure a consistently high quality standard and
Copyright and Trademarks
Copyright ?? 2006 Fujitsu Siemens Computers GmbH.
All rights reserved.
Delivery subject to availability; right of technical modifications reserved.
All hardware and software names used are trademarks of their respective manufacturers.
This manual is printed on paper treated with
Contents
Contents
1 About the KVM
The KVM
1.1Glossary
The following words are used throughout this documentation:
???ACI Port - ACI stands for ???analog console interface???. This is a port on some Fujitsu Siemens KVM switches that acts as an integrated
???ARI Port - ARI stands for ???analog rack interface???. The ARI Port is used to connect computers and KVM switches to KVM series2 and series3 KVM switches via a
???KVM
???
???switching system - a set of appliances and attached target devices and
???target device - equipment such as a server that is attached to an appliance by a
???local user - person with access to the keyboard, monitor, and mouse directly connected to the appliance. This user has full access to all target devices.
???remote user - an account in the local appliance user database or on a centralized Active Directory server. This account is used to provide management access to an appliance and its attached devices.
1.2Notational Conventions
The following notational conventions are used in this manual:
1.3Features and benefits
Figure 1: KVM
1.3.1
You can use the following
???KVM
???KVM
???KVM
PS/2 and VGA connectors
Figure 2: Example of a
These intelligent
The
The
1.3.2OSCAR graphical user interface
The KVM
1.3.3Security
Use the OSCAR interface to protect the switching system with a screen saver password. After a
1.3.4Operation modes
The OSCAR user interface provides various operation modes for system administration of the KVM
1.3.5Video
The KVM
1.3.6Flash upgradability
Upgrade the KVM
2 Installation
2.1Required items
Before you install the appliance, make sure that you have all the required items. The following items come with the KVM
???Power cord
???One null modem serial cable
???
???Documentation CD
???Quick Installation Guide
???Warranty Card
In addition to the items that come with the appliance, you must provide one
2.2Safety precautions
Observe the following guidelines to safely operate the equipment.
2.2.1General
???Observe and follow service markings.
???Do not service any appliance except as explained in the appliance documentation.
???The appliance contains no serviceable components. Do not attempt to open the appliance.
???Opening or removing covers that are marked with the triangular symbol with a lightning bolt might expose you to electrical shock. Components inside these compartments must be only serviced by a trained service technician.
???If any of the following conditions occur, disconnect the appliance from the electrical outlet and replace the part or contact the trained service provider:
???The power cable, extension cable, or connector is damaged.
???An object has fallen into the product.
???The appliance has been exposed to water.
???The appliance has been dropped or damaged.
???The appliance does not operate properly when you follow the operating instructions.
???Keep the appliance away from radiators and heat sources. Also, do not block cooling vents.
???Do not spill food or liquids on the appliance components, and never operate the appliance in a wet environment. If the appliance gets wet, see the applicable section in the troubleshooting guide or contact the trained service provider.
???Use the appliance only with approved equipment.
???Allow the appliance to cool before removing covers or touching internal components.
???Operate the appliance only from the type of external power source that is indicated on the electrical ratings label. If you are not sure of the type of power source that is required, consult the service provider or local power company.
???Be sure that the monitor and attached devices are electrically rated to operate with the power that is available in the current location.
???Use only power cables that are provided with the appliance.
???To help prevent electric shock, connect the appliance and peripheral power cables into properly grounded electrical outlets. These cables are equipped with three- prong connectors to help ensure proper grounding. Do not use adapter connectors or remove the grounding prong from a cable.
???Observe extension cable and power strip ratings. Make sure that the total ampere rating of all products that are connected to the power strip does not exceed 80 percent of the ampere ratings limit for the power strip.
???To help protect the appliance from sudden, transient increases and decreases in electrical power, use a surge suppressor, line conditioner, or uninterruptible power supply.
???Carefully position appliance cables and power cables. Route cables so that they cannot be stepped on or tripped over. Be sure that nothing rests on any cables.
???Do not modify power cables or connectors. Consult a licensed electrician or the power company for site modifications. Always follow the local and national wiring rules.
2.3Rack mounting the appliance
Before installing the appliance and other components in the rack (if not already installed), stabilize the rack in a permanent location. Install the equipment starting at the bottom of the rack, then work to the top. Avoid uneven loading or overloading of racks.
2.3.1General guidelines
???Refer to the rack installation documentation the accompanied the rack for specific caution statements and procedures.
???Elevated ambient temperature: In a closed rack assembly, the operation temperature of the rack environment can be greater than room ambient. Use care not to exceed the rated maximum ambient temperature of the unit.
???Reduced air flow: Carefully install the equipment in a rack so that an adequate amount of airflow is maintained for safe operation of the equipment.
???Mechanical loading: Avoid a potentially hazardous condition caused by uneven mechanical loading by carefully mounting the equipment in the rack.
???Circuit overloading: Consider the connection of the equipment to the supply circuit and the effect that overloading of circuits might have on overcurrent protection and supply wiring. Observe equipment nameplate ratings for maximum current.
Installation Installing the appliance horizontally in the 1U rack mounting space
???Reliable earthing: Maintain reliable earthing of
2.3.2Installing the appliance horizontally in the 1U rack mounting space
The filler panel must be placed in front of the rack when the appliance is mounted in the horizontal 1U orientation.
Remove the screws on each side of the appliance.
Line up the holes in the long side of each mounting bracket.
With a Phillips screwdriver, fasten the mounting brackets to the appliance using three 8/32 in. x 1/2 in.
Attach four cage nuts or clip nuts to the rack mounting flange of the rack so that the nut is positioned on the inside of the rack.
As shown in Figure 3, mount the appliance assembly to the rack by matching the holes in the short side of each mounting bracket to a set of matching holes on the rack. Insert the combination
Figure 3: Appliance horizontal installation
2.4Installing the KVM
Connect the supplied power cord into the rear of the appliance and then into a power source.
Figure 4 illustrates one possible configuration for the KVM
Power
cord
KVM
ARI ports
Configuration port
Ethernet
Figure 4: Basic KVM
2.4.1Connecting a
Attach the
Attach one end of the Cat 5 cable to the
Connect the other end of the Cat 5 cable to an ARI port on the rear of the KVM
Repeat steps 1 to 4 for all target devices that you are attaching.
2.4.2Connecting local peripheral devices
The KVM
Connect a keyboard, monitor, and mouse to the
Bundle and label the cables for easy identification.
2.5Adding earlier appliance models
You can add earlier appliance models for integration into the existing configuration. In a tiered switching system, each ARI port will accommodate one target device. When earlier appliance models are tiered under the KVM
Earlier appliance models include:
???KVM
???KVM
???KVM
The KVM
Figure 5 on page 10 illustrates an example of a tiered switching system, using the KVM
Local user
KVM
Earlier appliance models
Figure 5: Appliance configuration with earlier appliance models
2.5.1Attaching an earlier appliance model to the KVM
Mount the earlier appliance model into the rack according to the instructions that are included with that device.
If the tiered appliance is equipped with an Analog Rack Interface (ACI) port, attach one end of a Cat 5 cable directly to it. (If you are unsure if the appliance being tiered has an ACI port, please consult the Installer/User guide for the appliance you are tiering.) Otherwise, attach the keyboard, monitor, and mouse connectors of a KVM- IA to the local port on the tiered appliance and then attach one end of a Cat 5 cable to the end of the
Connect the other end of the Cat 5 cable to any available ARI port on the rear panel of the KVM
Turn off and turn on the target devices to the tiered appliance according to the instructions that are included with that device.
Turn off and turn on the tiered appliance to enable its local port to recognize the
Repeat the above steps for all tiered appliances that you want to attach to the switching system.The switching system will automatically merge the
two appliances.
All target devices that are connected to the tiered appliance are included in the main appliance target device list in the OSCAR interface. However, when an earlier appliance model is connected to a
2.5.2Attaching an incompatible switch model
It is possible to attach appliances that are not listed earlier in this chapter. Incompatible appliances do not support seamless tiering and devices attached to an incompatible appliance will not be displayed in the OSCAR menu for the KVM
Using the OSCAR interface, select the incompatible appliance.
Press the ESC key to deactiate the OSCAR interface for the KVM
Use the remaining OSCAR interface to select devices attached to the incompatible appliance.
2.6Setting up the KVM
With the KVM
3 Basic operations
3.1Controlling the switching system from the analog user port
The KVM
3.2Starting the OSCAR interface
You can view, configure, and control target devices in the switching system from the OSCAR interface from a KVM connection to the analog user port.
To start the OSCAR interface, press Print Screen.
Alternatively, you can press the Control, Alt, or Shift key twice within 1 second to start the OSCAR interface. You can use any of these key sequences instead of pressing Print Screen in any procedure in this document. To specify which key sequences can be used to start the OSCAR interface, click Setup - Menu.
The following illustration is an example of the Main window of the OSCAR interface.
Figure 6: Example of a Main window
The Main window lists the target devices in the switching system. You can order the list by target device names, EID numbers, or port numbers by clicking the Name, EID, or Port button.
The Port column indicates the ARI port to which each target device is connected. If an earlier appliance model is connected to a KVM
The status of each target device in the switching system is indicated by one or more status symbols in the right column. The following table describes the status symbols.
Symbol Description
The
The
The target device is tiered through another appliance. The target device and the appliance are online and have power.
The target device is tiered through another appliance. The appliance is offline or does not have power.
The
The
The
Table 1: OSCAR interface status symbols
You can set a screen delay to specify the length of time that elapses between when Print Screen is pressed and when the OSCAR interface starts.
Press Print Screen to start the OSCAR interface.
In the Main window, click Setup - Menu.
In the Screen Delay Time field, type the number of seconds that you want to elapse between when Print Screen is pressed and when the OSCAR interface starts.
3.3Connecting a user to a target device
Use the Main window of the OSCAR interface to select a target device to which you want to connect. When you select a target device, the keyboard and mouse are automatically reconfigured to the correct settings for that target device.
Press Print Screen to start the OSCAR interface, and then use one of the following procedures:
???In the Main window,
???Type the port number, and press Enter.
???Type the first few characters of the target device name or EID number, and press Enter.
You can toggle between two selected target devices. To select the previously selected target device, press Print Screen and press Backspace.
To disconnect the user from a target device, press Print Screen and press Alt+0. A Free status flag in the OSCAR interface indicates that the user is not connected to a target device.
3.4Using the OSCAR interface
This table describes the keys, key combinations, and mouse actions that you can use in the OSCAR interface. Two or more key names or mouse actions that are separated by commas indicate a sequence of actions. Two or more key names or mouse actions that are separated by a plus sign (+) indicate a combination of actions; that is, they are performed simultaneously.
You can use the main keyboard or the numeric keypad to type numerals, except when you use the Alt+0 key combination; you must use the 0 key on the main keyboard when you use Alt+0.
Table 2: OSCAR interface navigation basics
Using the OSCAR interfaceBasic operations
Table 2: OSCAR interface navigation basics (Continued)
3.5Configuring the appliance and the OSCAR interface
To configure the appliance and the OSCAR interface, start the OSCAR interface and click Setup. The following illustration shows the Setup window.
Figure 7: Setup window
The following table describes the options in the Setup window.
Table 3: Setup features to manage routine tasks for the target devices
Assigning target device namesBasic operations
Table 3: Setup features to manage routine tasks for the target devices (Continued)
3.5.1Assigning target device names
Use the Names window to identify individual target devices by name rather than by port number. The Names list is always sorted by port order. Names are stored in the KVM- IA, so even if you move the cable or target device to another ARI port, the name and configuration are recognized by the appliance. If a target device is turned off, you will not be able to modify the name of the applicable
3.5.1.1Accessing the Names window
Press Print Screen to start the OSCAR interface. The Main window opens.
Click Setup - Names. The Names window opens.
If the target device list changes, the mouse cursor will turn into an hourglass as the list is automatically updated. No mouse or keyboard input is accepted until the list update is complete.
3.5.1.2Assigning names to target devices
In the Names window, select a target device name or port number and click Modify. The Name Modify window opens.
Type a name in the New Name field. Names of target devices can be up to 15 characters long. Valid characters are A through Z, a through z, 0 through 9, space, and hyphen.
Click OK to transfer the new name to the Names window. The selection is not saved until you click OK in the Names window.
Repeat steps 1 to 3 for each target device in the switching system.
Click OK in the Names window to save the changes, or click X or press Escape to exit without saving changes.
3.5.2Assigning device types
The KVM
a configurable appliance from the list, the Modify button becomes available, so you can assign it the correct number of ports.
3.5.2.1Accessing the Devices window
Press Print Screen to start the OSCAR interface. The Main window opens.
Click Setup - Devices. The Devices window opens.
Figure 8: Devices window
When the KVM
3.5.2.2Assigning a device type
In the Devices window, select the port number.
Click Modify. The Device Modify window opens.
Figure 9: Device Modify window
Select or type the number of ports that are supported by the tiered appliance and click OK.
Repeat steps 1 to 3 for each port for which you want to assign a device type.
Click OK in the Devices window to save settings.
3.5.3Changing the display behavior
Use the Menu window to change the order of target devices and set a screen delay for the OSCAR interface. The display order setting affects the order in which target devices are listed in several windows, including the Main and Devices windows.
3.5.3.1Accessing the Menu window
Press Print Screen to start the OSCAR interface. The Main window opens.
Click Setup - Menu. The Menu window opens.
Figure 10: Menu window
3.5.3.2Selecting the order of the target devices
Click one of the following buttons:
???Select Name to list the target devices alphabetically by target device name.
???Select EID to list the target devices numerically by EID number.
???Select Port to list the target devices numerically by port number.
Click OK.
3.5.3.3Selecting a key combination to start the OSCAR interface
In the Invoke OSCAR section, select which key combinations you want to use to start the OSCAR interface, then press your selected combination.
Click OK.
You can set a screen delay so that you can select a target device using the keyboard without starting the OSCAR interface. A screen delay specifies the length of time that elapses between when Print Screen is pressed and when the OSCAR interface starts.
3.5.3.4Setting a screen delay
Type the number of seconds (0 through 9) to specify the length of time that elapses between when Print Screen is pressed and when the OSCAR interface starts. If you specify 0, there is no delay.
Click OK.
3.5.4Selecting display language
Use the Setup window to change the display language for the OSCAR interface.
Figure 11: Language window
Press Print Screen to start the OSCAR interface. The Main window opens.
Click Setup - Language. The Language window opens.
In the Language window, select the language and click OK.
3.5.5Controlling the status flag
The status flag is displayed on the desktop and indicates the name or EID number of the selected target device or the status of the selected port. You can specify the information that is displayed in the flag, the flag color, whether the desktop is visible through the flag, whether the flag is displayed all the time, and where the flag is displayed on the desktop. Table 4 shows examples of status flags.
Table 4: OSCAR interface status flags
3.5.5.1Specifying the
1.Press Print Screen. The Main window opens.
2.Click Setup - Flag.
3. Set one or more of the following settings:
???Select Name or EID to specify the information that is displayed in the flag.
???Select Displayed to display the flag all the time, or select Timed to display the flag for only 5 seconds after you select a target device.
???In the Display Color section, select the flag color.
???Select Opaque to make the flag solid, or select Transparent to make the desktop visible through the flag.
???To specify the position of the flag, complete the following steps: a.Click Set Position.
b.Hold down the left mouse button on the title bar of the Set Position window, and drag the window to the new location.
c.Press the right mouse button to close the Set Position window.
4. Click OK to save the changes, or click X or press Escape to exit without saving the changes.
3.5.6Setting the keyboard country code
By default, the appliance sends the US keyboard country code to USB cables attached to target devices and the code is applied to the target devices when they are turned on or rebooted. Codes are then stored in the
Issues might arise when you use the US keyboard country code with a keyboard of another country. For example, the Z key on a US keyboard is in the same location as the Y key on a German keyboard.
You can use the Keyboard window to send a different keyboard country code than the default US setting.
Figure 12: Keyboard window
3.5.6.1Changing the keyboard country code
Press Print Screen to start the OSCAR interface. The Main window opens.
Click Setup - Keyboard. The Keyboard window opens.
Select the country code for the keyboard, and click OK. Confirm the change in the Keyboard Warning window.
Click OK to save the change, or click X or press Escape to exit without saving the change.
3.5.6.2Setting appliance security
You can enable a screen saver to start if the user remains unused for a specified length of time. When the screen saver starts, the user is disconnected from any target device to which it was connected. The screen saver stops when you press any key or move the mouse.
To immediately start the screen saver, press Print Screen and press Pause.
If you set a password, the keyboard and mouse are locked when the screen saver starts. When you press a key or move the mouse while the screen saver is running, a Password window opens, and you must type the password and click OK to unlock the keyboard and mouse.
If you forget the password, you must call technical support. See Appendix 5.4 Technical Support on page 45 for contact information.
3.5.6.3Enabling the screen saver
Press Print Screen. The Main window opens.
Click Setup - Security. If a password is set, the Password window opens. Type the password and click OK.
Select the Enable Screen Saver check box.
In the Inactivity Time field, type the number of seconds (1 through 99) that must elapse before the screen saver starts.
If the monitor is Energy Star compliant, select Energy; otherwise, select Screen.
(Optional) To run the
Click OK.
3.5.6.4Disabling the screen saver
Press Print Screen. The Main window opens.
Click Setup - Security. If a password is set, the Password window opens. Type the password and click OK.
Clear the Enable Screen Saver check box.
Click OK.
A password must contain both alphabetic and numeric characters and can be up to 12 characters long. Passwords are
3.5.6.5Setting or changing a password
Press Print Screen. The Main window opens.
Click Setup - Security. If a password is already set, the Password window opens. Type the password and click OK.
In the New field, type the new password.
In the Repeat field, type the password again.
Click OK.
3.5.6.6Disabling password protection
Press Print Screen. The Main window opens.
Click Setup - Security. In the Password window, type the password and click OK.
Click OK.
3.6Managing target device tasks using the OSCAR interface
From the Commands window, you can manage the switching system and user connections, enable Scan mode, and update the firmware.
Table 5: Commands to manage routine tasks for the target device
3.6.1Accessing the Commands window
Press Print Screen. The Main window opens.
Click Commands. The Commands window opens.
Figure 13: Commands window
3.6.2Displaying version information
You can use the OSCAR interface to view the versions of the KVM
Press Print Screen. The Main window opens.
Click Commands - Display Versions. The Version window opens. The top pane of the window lists the subsystem versions in the appliance.
Figure 14: Version window
Click the
Select a
Click X to close the CO Version window.
3.6.3Upgrading the firmware
You can also use the OSCAR interface to upgrade the firmware available for the KVM
Figure 15: Upgrade window
Press Print Screen. The Main window opens.
Click Commands - Display Versions - Upgrade. The Upgrade window opens.
Click Upgrade. A Warning window opens. Clicking OK opens the Upgrade Process window. The progress of the upgrade is indicated in the Programmed field.
3.7Viewing the current display configuration
Use the Display Configuration window to view the current configuration of the KVM s2- 0411 switching system.
Click Commands - Display Config. The Display Configuration window opens and lists the current system configuration values.
3.8Viewing and disconnecting user connections
You can view and disconnect users from target devices through the User Status window. The user (U) is always visible; however, you can display either the target device name or EID number to which a user is connected. If no user is currently connected, both the User and Server Name fields are blank.
Figure 16: User Status window
3.8.0.1Viewing current user connections
Click Commands - User Status. The User Status window opens.
3.8.0.2Disconnecting a user
From the User Status window, click the letter that corresponds to the user to disconnect. The Disconnect window opens.
Complete one of the following steps:
???Click OK to disconnect the user and return to the User Status window.
???Click X or press Escape to exit the window without disconnecting a user.
If the User Status list has changed since it was last visible, the mouse cursor will turn into an hourglass as the list is automatically updated. No mouse or keyboard input is accepted until the list update is complete.
3.8.0.3Resetting the keyboard and mouse
You can reset the keyboard and mouse by clicking Commands - Device Reset. If the keyboard or mouse is still not responding, you might be able to
appliance. With communication
This function is for Microsoft
Press Print Screen. The Main window opens.
Click Commands - Display Versions -
Click Version - Reset.
A message is displayed stating that the mouse and keyboard are reset.
Complete one of the following steps:
???Click OK to close the message field.
???Click X or press Escape to exit without sending a Reset command to the mouse and keyboard.
3.9Scanning the switching system
In scan mode, the appliance automatically scans from port to port (target device to target device). Use scan mode to monitor the activity of up to 100 target devices, and to specify which target devices to scan and the number of seconds that each target device will be visible. The scanning order is determined by placement of the target device in the list, which is always shown in scanning order. You can choose to list the target devices by name, EID number, or port number by clicking the corresponding button.
3.9.1Adding target devices to the scan list
Click Setup - Scan. The Scan window opens
.
Figure 17: Scan window
The window contains a listing of all target devices that are attached to the appliance. To select target devices to be scanned, complete one of the following steps:
???Select the check box next to the target devices that you want to scan.
???
???Press Alt and the EID number of the target device that you want to scan. You can select up to 16 target devices from the list.
In the Time field, type the number of seconds (from 3 to 255) of time before the scan moves to the next target device in the sequence.
Click OK.
3.9.2Removing a target device from the scan list
Complete one of the following steps:
???In the Scan window, clear the check box next to the target device to be removed.
???
???Press Shift + Delete to remove the selected target device and all entries below it.
???Click the Clear button to remove all target devices from the scan list.
Click OK.
3.9.3Starting the scan mode
Click Commands. The Commands window opens.
Figure 18: Commands window
Select Scan Enable in the Commands window. Scanning will be begin immediately.
Click X to close the Commands window.
3.9.4Canceling scan mode
Complete one of the sollowing steps:
If the OSCAR interface is open, select a target device.
If the OSCAR interface is not open, move the mouse or press any key on the keyboard to stop scanning at the currently selected target device.
3.10Running switching system diagnostics
You can validate the integrity of the switching system through the Run Diagnostics command. This command checks the main board functional
The Diagnostics window opens. The top section of the window opens the hardware tests. The bottom portion divides the tested
Figure 19: Diagnostics window
Next to each item that will be tested, you will see a pass (green circle) or fail (red x) symbol to the left of each item as that test finishes. The following table details each of the tests.
Table 6: Diagnostic test details
3.10.1Running diagnostic tests
Click Commands - Run Diagnostics. A warning message indicates that all users will be disconnected.
Click OK to begin diagnostics.
All users are disconnected and the Diagnostics window opens.
As each test is finished, a pass (green circle) or fail (red x) symbol is visible. The test is complete when the last test symbol is visible.
4 Computer terminal operations
4.1The Console menu
Each appliance can be configured at the appliance level through the Console menu interface accessed through the configuration port on the rear of the appliance. All terminal commands are accessed through a terminal or computer running terminal emulation software.
4.1.1Configuring the network using the Console menu
When you turn on the appliance, the appliance initializes for approximately one minute. After it completes initialization, press any key on the terminal or on the computer running the terminal emulation software to access the Console menu interface. The terminal can be connected at any time, even when the appliance is already turned on.
The Console Main menu opens. Type 1 and press Enter for the Network Configuration option. The Network Configuration menu opens.
Figure 20: Network configuration menu
Type 1 and press Enter to set the network speed. You should set the connection manually without relying on the auto negotiate feature. After pressing Enter, you are returned to the Network Configuration menu.
Type 2 and press Enter to specify whether you are using a static or Dynamic Host Configuration Protocol (DHCP) address.
A static IP address can be used to provide a
When DHCP is selected, the IP Address, Netmask, and Default Gateway settings are automatically assigned to the appliance and cannot be modified by a user. If you are using the DHCP option, configure the DHCP target device to provide an IP address to the appliance and then skip step 5.
Select the remaining options from the Network Configuration menu to finish the configuration of the appliance with an IP address, netmask, default gateway, and ping response.
Type 0 (zero) and press Enter to return to the Console Main menu. The appliance will then reboot.
4.1.2Other Console Main menu options
Besides the Network Configuration option, the Console Main menu of the appliance has the following menu items: Security Configuration, Firmware Management, Enable Debug Messages, Restore Factory Defaults, Reset Appliance, and Exit. Each is discussed in the following section.
4.1.2.1Security configuration
Console Password: Enable or disable the console password using security for the console (access requires an Admin account).In the event that you forgot the password, type Help. You will be given a one time use key to supply to technical support, who will then supply you with a one time use password that you can use to access the Serial Port.
4.1.2.2Firmware management
This menu contains the Flash Download selection. For more information, see Appendix A: Flash Upgrades.
4.1.2.3Enable debug messages
This menu option turns on console status messages. Because this can significantly reduce performance, you should only enable debug messages when instructed to do so by technical support. When you are finished viewing the messages, press any key to exit this mode.
4.1.2.4Restore factory defaults
This menu option will restore all appliance options to the default settings.
4.1.2.5Reset appliance
You can use this menu option to initiate a soft reset of the appliance.
4.1.2.6Exit
This menu selection will return you to the ready prompt.
5 Appendices
5.1Flash upgrades
5.1.1Upgrading the KVM
Use the KVM
Items needed for the upgrade
???Target device that is running a terminal program
???Available serial port (COM port) on the target device
???Serial cable that connects the appliance and the target device
???Firmware update
5.1.2Upgrading a new Flash file
Go to
Connect a computer running terminal emulation software to the configuration port on the rear panel of the appliance using the supplied Null Modem serial cable.The terminal should be set to 9600 bps, 8 bits, 1 stop bit, no parity, and no flow control.
If the appliance is not on, turn it on now. After approximately one minute, press any key to access the Console Main menu.
The Console Main menu opens. Select the Firmware Management option. The current version of the firmware is opened on the Firmware Management menu.
Type 1 and press Enter to select Flash Download.
Type the IP address of the TFTP target device and press Enter.
Type the name of the Flash file and press Enter.
Confirm the TFTP download by typing a y or yes and pressing Enter.
The appliance will verify that the file you downloaded is valid. Next, you are prompted to confirm the upgrade. Type a y or yes and press Enter to confirm.
The appliance begins the Flash upgrade process.
After the upgrade is complete, a verification message is displayed.
5.1.3Upgrading the
The
5.1.3.1Simultaneously upgrading multiple
Press Print Screen. The Main window opens.
Click Commands >
Figure 21:
Click one or more types of modules to upgrade. Click Upgrade.
The
5.1.3.2Upgrading
Press Print Screen. The Main window opens.
Click Commands > Display Versions. The
Figure 22:
Click
Figure 23:
Select a
Click the Load Firmware button. The
Click OK to initiate the upgrade and return to the Status window.
During an upgrade, the
5.1.4Repairing damaged firmware
In the rare case that the firmware is damaged after a firmware upgrade (which might happen if the appliance is turned off and turned on during the upgrade process), the appliance will remain in boot mode. In this mode, the Power LED at the rear panel flashes at about 1Hz, and the appliance attempts to restore the firmware over TFTP using the following default configuration:
???TFTP client IP address 10.0.0.2
???TFTP target device IP address 10.0.0.3
???Upgrade file name equal to
5.1.4.1Repairing damaged firmware
Connect the appliance to the TFTP target device (using a
Rename the upgrade file to the default file name
The Power LED will Flash at about 2 Hz when the appliance is downloading the upgrade file, and it will Flash at about 4 Hz when it is programming the downloaded file to Flash. After it has successfully restored the firmware, the appliance reboots automatically and the Power LED illuminates.
5.2UTP cabling
The following information is intended to brief you on various aspects of connection media. The performance of a switching system depends on high quality connections. Poor quality or poorly installed or maintained cabling can diminish system performance.This appendix is for information purposes only. Consult with the local code officials or cabling consultants prior to any installation.
5.2.1UTP copper cabling
Switching systems utilize unshielded twisted pair (UTP) cabling.The following are basic definitions for the three types of UTP cabling that the appliance supports:
???Cat 5 UTP
???Cat 5E (enhanced) cable has the same characteristics as Cat 5, but is manufactured to somewhat more stringent standards.
???Cat 6 cable is manufactured to tighter requirements than Cat 5E cable. Cat 6 has higher measured frequency ranges and significantly better performance requirements than Cat 5E cable at the same frequencies.
5.2.2Wiring standards
There are two supported wiring standards for
Table 7: UTP wiring standards
5.2.3Cabling installation, maintenance, and safety tips
The following is a list of important safety considerations that should be reviewed prior to installing or maintaining the cables:
???It is best to keep all Cat 5 runs to a maximum of 10 meters each; however, some cables may run longer.
???Maintain the twists of the pairs all the way to the point of termination, or no more that
???If bending the cable is necessary, make it gradual with no bend sharper than a one inch radius. Sharply bending or kinking the cable can permanently damage the interior of the cable.
???Arrange the cables neatly with cable ties, using low to moderate pressure. Do not over tighten ties.
???
???Keep the Cat5 cable as far away as possible from potential sources of EMI, such as electrical cables, transformers, and light fixtures. Do not tie cables to electrical conduits or lay cables on electrical fixtures.
???Always test every installed segment with a cable tester. Toning alone is not an acceptable test.
???Always install jacks to prevent dust and other contaminants from settling on the contacts. The contacts of the jack should face up on the flush mounted plates, or left, right, or down on surface mount boxes.
???Always leave extra slack in the cables, neatly coiled in the ceiling or nearest concealed location. Leave at least five feet at the work outlet side and 10 feet at the patch panel side.
???Choose either 568A or 568B wiring standard before beginning. Wire all jacks and patch panels for the same wiring scheme. Do not mix 568A and 568B wiring in the same installation.
???Always follow all local and national fire and building codes. Be sure to firestop all cables that penetrate a firewall. Use
5.3Technical specifications
Target Server Ports
Table 8: Product specifications
5.4Technical Support
Our Technical Support staff is ready to assist you with any installation or operating issues you encounter with your Fujitsu Siemens product. If an issue should develop, follow the steps below for the fastest possible service: Check the pertinent section of this manual to see if the issue can be resolved by following the procedures outlined. Check our web site at
5.4.1Before you call
Before you call, make sure that you have taken these steps to try to solve the problem yourself:
???Check all cables to make sure that they are connected.
???Check the power switches to make sure that the system and any optional devices are turned on.
???Use the troubleshooting information in your system documentation, and use the diagnostic tools that come with your system.
???Go to the Fujitsu Siemens support Web site at
You can solve many problems without outside assistance by following the troubleshooting procedures that Fujitsu Siemens provides in the online help or in the documentation that is provided with your Fujitsu Siemens product. If you suspect a software problem, see the documentation for the operating system or program.
KVM
Auflage Januar 2006
Kommentare??? Vorschl??ge??? Verbesserungen
Unsere Abteilung f??r technische Dokumentation w??rde gerne Ihre Meinung zu diesem Handbuch erfahren. Ihr Feedback hilft uns, unsere Dokumentation zu optimieren, indem Ihre individuellen Anforderungen erf??llt werden. Sie finden hinten im Handbuch Fax- Formulare, mit denen Sie uns Ihre Kommentare zuschicken k??nnen. Dort befindet sich auch die Adresse der entsprechenden Abteilung f??r technische Dokumentation.
Zertifizierte Dokumentation nach DIN EN ISO 9001:2000
Zur Sicherstellung von konsistent hohen Qualit??tsstandards und Benutzerfreundlichkeit wurde diese Dokumentation in ??bereinstimmung mit den Vorschriften eines Qualit??tssicherungssystems erstellt, das den Anforderungen der Norm DIN EN
ISO 9001:2000 entspricht.
Copyright und Marken
Copyright ?? 2006 Fujitsu Siemens Computers GmbH.
Alle Rechte vorbehalten.
Lieferm??glichkeiten und technische ??nderungen vorbehalten.
Alle verwendeten Hardware- und Softwarebezeichnungen sind Marken der entsprechenden Hersteller.
Dieses Handbuch ist auf chlorfrei gebleichtem Papier gedruckt.
2.5.1Anschlie??en eines ??lteren Einheitenmodells an die
Inhalt
3.5.3.3Ausw??hlen einer Tastenkombination zum Starten der
3.6Verwalten der Aufgaben der Zielger??te ??ber die
Inhalt
1 Die KVM
Die KVM
1.1Glossar
In diesem Handbuch werden die folgende Begriffe verwendet:
???
???
???KVM
???
???
???Zielger??t: Ein Ger??t, das ??ber einen
???Lokaler Benutzer: Benutzer mit Zugriff auf Tastatur, Bildschirm und Maus, die direkt mit der Einheit verbunden sind. Dieser Benutzer hat uneingeschr??nkten Zugriff auf alle Zielger??te.
???
1.2Darstellungskonventionen
In diesem Handbuch werden die folgenden Darstellungskonventionen verwendet:
1.3Merkmale und Vorteile
Abbildung 1: KVM
1.3.1
Sie k??nnen die folgenden
???KVM
???KVM
???KVM
PS/2- und
Abbildung 2: Beispiel f??r ein
Diese intelligenten
Die
Die
1.3.2Grafische Benutzeroberfl??che OSCAR
Die KVM
1.3.3Sicherheit
Verwenden Sie die
1.3.4Betriebsmodi
Die
1.3.5Video
Die KVM
1.3.6
Die KVM
2 Installation
2.1Erforderliche Komponenten
Stellen Sie vor der Installation der Einheit sicher, dass alle erforderlichen Komponenten vorhanden sind. Die folgenden Komponenten sind im Lieferumfang der KVM
???Netzkabel
???Ein serielles Nullmodemkabel
???Rackbefestigungshalterungen und
???
???Schnellinstallationsanleitung
???Garantiekarte
Zus??tzlich zu den im Lieferumfang der Einheit enthaltenen Komponenten ben??tigen Sie einen
2.2Sicherheitsvorkehrungen
Beachten Sie die folgenden Anweisungen, um einen sicheren Betrieb der Ger??te zu gew??hrleisten.
2.2.1Allgemeine Sicherheitshinweise
???Beachten und befolgen Sie die Wartungsbeschriftungen.
???Nehmen Sie keine Wartungsarbeiten an der Einheit vor, die nicht in der entsprech- enden Dokumentation erkl??rt sind.
???Die Einheit enth??lt keine Komponenten, die vom Benutzer gewartet werden k??nnen. Die Einheit nicht ??ffnen.
???Beim ??ffnen und Entfernen von Abdeckungen, die mit dem dreieckigen Symbol mit Blitzzeichen gekennzeichnet sind, besteht die Gefahr eines elektrischen Strom- schlags. Die Komponenten in diesen Bereichen der Einheiten d??rfen nur von qualifizierten Wartungstechnikern gewartet werden.
???Falls eine der folgenden Situationen eintritt, trennen Sie die Verbindung der Einheit mit der Stromversorgung und ersetzen Sie das betreffende Teil oder nehmen Sie Kontakt mit einem Fachh??ndler auf:
???Das Netzkabel, Verl??ngerungskabel oder Stecker sind besch??digt.
???Ein Gegenstand ist in das Produkt gefallen.
???Die Einheit ist mit Wasser in Ber??hrung gekommen.
???Die Einheit ist heruntergefallen und/oder wurde besch??digt.
???Die Einheit funktioniert nicht ordnungsgem????, obwohl Sie die Bedienungsanleitung befolgen.
???Stellen Sie die Einheit in sicherer Entfernung von Heizk??rpern und W??rmequellen auf. Achten Sie darauf, dass die L??fter??ffnungen nicht blockiert sind.
???Achten Sie darauf, die Komponenten der Einheit nicht mit Nahrungsmitteln oder Fl??ssigkeiten zu verunreinigen und betreiben Sie die Einheit nicht in feuchter Umgebung. Wenn die Einheit Feuchtigkeit ausgesetzt wurde, sehen Sie im entsprechenden Abschnitt der Anleitung zur St??rungsbeseitigung nach oder nehmen Sie Kontakt mit einem geschulten Wartungstechniker auf.
???Verwenden Sie die Einheit nur mit zugelassenen Ger??ten.
???Lassen Sie die Einheit abk??hlen, bevor Sie Abdeckungen entfernen oder interne Komponenten ber??hren.
???Betreiben Sie die Einheit nur mit einer externen Stromversorgung, die den auf dem Produktaufkleber angegebenen elektrischen Nennwerten entspricht. Wenn Unklarheiten dar??ber bestehen, welche Art von Stromversorgung ben??tigt wird, nehmen Sie Kontakt mit Ihrem Fachh??ndler oder der ??rtlichen Elektrizit??tsgesell- schaft auf.
???Stellen Sie sicher, dass der Monitor und die angeschlossenen Ger??te ??ber die elektrischen Nennwerte verf??gen, um mit vor Ort verf??gbaren Stromversorgung betrieben werden zu k??nnen.
???Verwenden Sie nur die mit der Einheit mitgelieferten Stromkabel.
???Zur Vermeidung von Stromschl??gen m??ssen die Netzkabel der Einheit und der Peripherieger??te an ordnungsgem???? geerdete Netzsteckdosen angeschlossen werden. Diese Kabel sind mit dreipoligen Steckern versehen, um eine ordnungsge- m????e Erdung sicherzustellen. Verwenden Sie keine Adapterstecker und entfernen Sie den Erdungsanschluss nicht vom Kabel.
???Beachten Sie die Nennleistung von Verl??ngerungskabeln und Mehrfachsteck- dosen. Stellen Sie sicher, dass die
???Sch??tzen Sie die Einheit vor pl??tzlichen kurzzeitigen Stromschwankungen durch einen ??berspannungsschutz, Line Conditioner oder eine unterbrechungsfreie Stromversorgung (USV).
???Verlegen Sie alle Kabel und Stromkabel der Einheit mit gr????ter Sorgfalt. Verlegen Sie die Kabel so, dass man nicht darauf tritt oder dar??ber stolpert. Stellen Sie sicher, dass keine Gegenst??nde auf den Kabeln liegen.
???Nehmen Sie keine ??nderungen an Netzkabeln und Anschl??ssen vor. Wenden Sie sich f??r standortspezifische ??nderungen an einen qualifizierten Elektriker oder die zust??ndige Elektrizit??tsgesellschaft. Befolgen Sie stets die ma??geblichen Verkabel- ungsvorschriften.
2.3Rackbefestigung der Einheit
Vor der Installation der Einheit und anderer Komponenten im Rack (falls noch nicht installiert) muss das Rack am vorgesehenen Standort stabilisiert werden. Best??cken Sie das Rack von unten nach oben mit Komponenten. Vermeiden Sie eine ungleichm????ige Belastung und achten Sie darauf, dass das Rack nicht ??berladen wird.
2.3.1Allgemeine Anweisungen
???Beachten Sie die im Lieferumfang enthaltene Installationsdokumentation bez??glich spezifischer Vorsichtshinweise und
???Erh??hte Umgebungstemperaturen: In geschlossenen Racks kann es vorkommen, dass die Betriebstemperatur in der Umgebung des Racks h??her als die Raumtemperatur ist. Achten Sie darauf, dass die auf der Einheit angegebene maximale Umgebungstemperatur nicht ??berschritten wird.
???Unzureichende Bel??ftung: Installieren Sie die Ger??te umsichtig im Rack, so dass eine ausreichende Luftzufuhr f??r den sicheren Betrieb der Ger??te gew??hrleistet ist.
???Mechanische Belastung: Vermeiden Sie m??gliche Gefahrensituationen, die durch eine ungleichm????ige mechanische Belastung verursacht werden, indem Sie die Ger??te umsichtig im Rack befestigen.
???Stromkreis??berlastung: Achten Sie darauf, welche Auswirkungen der Anschluss der Ger??te an den Versorgungsstromkreis und eine ??berlastung des Stromkreises auf den ??berlastungsschutz und die Netzverkabelung haben k??nnen. Beachten Sie die maximalen Spannungswerte auf den Typenschildern der Ger??te.
???Zuverl??ssiger Erdungsanschluss: Stellen Sie sicher, dass rackmontierte Ger??te stets ??ber einen zuverl??ssigen Erdungsanschluss verf??gen. Achten Sie vor allem auf Stromanschl??sse, die nicht direkt an den Versorgungsstromkreis angeschlos- sen sind (z. B. bei Verwendung von Mehrfachsteckdosen).
2.3.2Horizontale Installation der Einheit in den 1
Die Blende muss vor dem Rack platziert werden, wenn die Einheit in der horizontalen 1 HE Position befestigt werden soll.
Entfernen Sie die Schrauben an jeder Seite der Einheit.
Richten Sie die Bohrungen an der langen Seite jeder Befestigungshalterung entsprechend aus.
Montieren Sie die Befestigungshalterungen auf jeder Seite der Einheit mit einem Kreuzschlitzschraubendreher und drei Nr. 8/32" x
Befestigen Sie vier K??figmuttern oder Schnappmuttern so am Rackbefestigungs- flansch des Racks, dass die Mutter auf der Rackinnenseite positioniert ist.
Bauen Sie die Einheit wie in Abbildung 3 gezeigt in das Rack ein, indem die Bohrungen in der kurzen Seite der Befestigungshalterung auf einen entsprech- enden Satz passender Bohrungen des Racks ausrichten. Als n??chstes f??hren Sie die
Abbildung 3: Horizontale Installation der Einheit
2.4Installieren der KVM
Schlie??en Sie das mitgelieferte Stromkabel hinten an die Einheit und dann an eine Stromquelle an.
Abbildung 4 zeigt eine m??gliche Konfiguration der KVM
Strom-
kabel
KVM
Konfigurations- port
Ethernet
Abbildung 4: Beispiel einer einfachen KVM
2.4.1Anschlie??en eines
Schlie??en Sie die farbkodierten Stecker des
Schlie??en Sie ein Ende des CAT
Schlie??en Sie das andere Ende des CAT
Wiederholen Sie die Schritte 1 bis 4 f??r alle Zielger??te, die angeschlossen werden sollen.
2.4.2Anschlie??en von lokalen Peripherieger??ten
Die KVM
Schlie??en Sie Tastatur, Bildschirm und Maus an die farbkodierten Ports auf der R??ckseite der Einheit an.
B??ndeln Sie die Kabel zu einem Kabelstrang und kennzeichnen Sie sie zur einfacheren Identifikation.
2.5Hinzuf??gen ??lterer Einheitenmodelle
Sie k??nnen ??ltere Einheitenmodelle in die bestehende Konfiguration integrieren. In einem gestuften
Zu den ??lteren Einheiten z??hlen unter anderem:
???KVM
???KVM
???KVM
Nur die KVM
Abbildung 5 auf Seite 11 zeigt ein Beispiel eines gestuften
KVM
??ltere Einheiten- modelle
Abbildung 5:
2.5.1Anschlie??en eines ??lteren Einheitenmodells an die KVM
Befestigen Sie die ??ltere Einheit im Rack und beachten Sie dabei die geltenden Anweisungen.
Schlie??en Sie ein Ende eines CAT
Schlie??en Sie das andere Ende des CAT
Schalten Sie die mit der gestuften Einheit verbundenen Zielger??te aus und wieder ein und beachten Sie dabei die geltenden Anweisungen.
Schalten Sie die gestufte Einheit aus und wieder ein, damit der lokale Port den
Wiederholen Sie die oben aufgef??hrten Schritte f??r alle gestuften Einheiten, die Sie an Ihr
Alle Zielger??te, die mit der gestuften Einheit verbunden sind, werden in der Zielger??teliste der
2.5.2Anschlie??en eines nicht kompatiblen Switch- Modells
Es besteht die M??glichkeit, Einheiten anzuschlie??en, die nicht weiter vorne in diesem Kapitel aufgelistet sind. Nicht kompatible Einheiten unterst??tzen die nahtlose Stufung nicht und Ger??te, die an eine nicht kompatible Einheit angeschlossen sind, werden im
W??hlen Sie ??ber die
Geben die Sie OSCAR Aktivierungstastenfolge erneut ein. Dadurch wird die
Dr??cken Sie ESC, um die Benutzeroberfl??che f??r die KVM
W??hlen Sie ??ber die verbleibende
2.6Einrichten der KVM
Die KVM
3 Normalbetrieb
3.1Steuern des
Die KVM
3.2Aufrufen der
??ber die
Bet??tigen Sie die Taste Druck, um die
Alternativ k??nnen Sie auch die Taste Strg, Alt oder die Umschalttaste zweimal innerhalb einer Sekunde bet??tigen, um die
Die folgende Abbildung zeigt ein Beispiel des Hauptmen??s der OSCAR- Benutzeroberfl??che.
Abbildung 6: Beispiel eines Hauptmen??s
Das Hauptmen?? listet die Zielger??te im
Die Spalte Port zeigt den
Der Status jedes Zielger??ts im
Symbol Beschreibung
Der
Der
Das Zielger??t ist ??ber eine weitere Einheit gestuft. Das Zielger??t und die Einheit sind online und werden mit Strom versorgt.
Das Zielger??t ist ??ber eine weitere Einheit gestuft. Die Einheit ist offline oder wird nicht mit Strom versorgt.
Der
Auf den
Der
Tabelle 1: Statussymbole der
Sie k??nnen eine Zeitverz??gerung einstellen, um festzulegen, wie viel Zeit zwischen dem Bet??tigen der Taste ???Druck??? und dem Starten der
Bet??tigen Sie die Taste Druck, um die
Klicken Sie im Hauptmen?? auf Setup - Men??.
Geben Sie im Feld Zeitverz??gerung die Anzahl an Sekunden ein, die zwischen dem Bet??tigen der Taste ???Druck??? und dem Starten von OSCAR verstreichen sollen.
3.3Verbinden eines Benutzers mit einem Zielger??t
W??hlen Sie im Hauptmen?? der
Bet??tigen Sie die Taste Druck, um die
???Doppelklicken Sie im Hauptmen?? auf den Namen, die EID- oder die Portnummer des Zielger??ts.
-oder -
???Geben Sie die Portnummer ein und bet??tigen Sie die Eingabetaste.
-oder -
???Geben Sie die ersten Buchstaben oder Ziffern des Namens bzw. der EID- Nummer des Zielger??ts ein und bet??tigen Sie die Eingabetaste.
Sie k??nnen zwischen zwei ausgew??hlten Zielger??ten hin- und herschalten. Bet??tigen Sie die Taste Druck und danach die R??cktaste, um das zuvor ausgew??hlte Zielger??t auszuw??hlen.
Bet??tigen Sie die Taste Druck und danach Alt+0, um die Verbindung des Benutzers mit dem Zielger??t zu trennen. Das Statusflag ???Frei??? auf der
3.4Verwenden der
Diese Tabelle beschreibt die Tasten, Tastenfolgen und Mausaktionen, die Sie in der
Sie k??nnen die Haupttastatur oder die Zehnertastatur zur Eingabe von Nummern ver- wenden. Eine Ausnahme ist die Eingabe der Tastenfolge Alt+0, hier muss die 0 der Haupttastatur verwendet werden.
Tabelle 2: Grundlagen der
Verwenden der
Tabelle 2: Grundlagen der
Normalbetrieb Konfiguration der Einheit und der
Tabelle 2: Grundlagen der
3.5Konfiguration der Einheit und der OSCAR- Benutzeroberfl??che
Starten Sie die
Abbildung 7: Dialogfeld ???Setup???
Die folgende Tabelle beschreibt die Optionen im Dialogfeld ???Setup???.
Tabelle 3:
Option Zweck
Scannen Einrichten eines benutzerdefinierten
Switch Den Modus der Einheit einstellen.
Netzwerk Einstellen von Netzwerkgeschwindigkeit und
Tabelle 3:
3.5.1Zuweisen von Zielger??tenamen
Verwenden Sie das Dialogfeld ???Namen???, um individuelle Zielger??te nach Namen und nicht nach Portnummern zu identifizieren. Die Namensliste wird immer nach Portnum- mer sortiert. Namen werden im
3.5.1.1Zugriff auf das Dialogfeld ???Namen???
Bet??tigen Sie die Taste Druck, um die
Klicken Sie auf Setup - Namen. Das Dialogfeld ???Namen??? wird ge??ffnet.
Wenn sich die Liste der Zielger??te ??ndert, wird der Mauszeiger als Sanduhrsymbol angezeigt, w??hrend sich die Liste automatisch aktualisiert. Erst nach abgeschlossener Aktualisierung der Liste werden wieder Tastatur- und Mauseingaben akzeptiert.
3.5.1.2Zuweisen von Zielger??tenamen
W??hlen Sie den Namen oder die Portnummer des gew??nschten Zielger??ts im Dialogfeld Namen aus und klicken Sie auf die Schaltfl??che ??ndern. Das Dialogfeld ???Namen ??ndern??? wird ge??ffnet.
Geben Sie einen Namen in das Feld Neuer Name ein. Namen der Zielger??te k??nnen bis zu 15 Zeichen lang sein. G??ltige Zeichen sind
Klicken Sie auf OK, um den neuen Namen in das Dialogfeld ???Namen??? zu ??berneh- men. Die Auswahl wird erst gespeichert, wenn Sie im Dialogfeld ???Namen??? auf OK klicken.
Wiederholen Sie die Schritte 1 bis 3 f??r jedes Zielger??t im
Klicken Sie im Dialogfeld ???Namen??? auf OK, um die ??nderungen zu speichern. Wenn Sie das Dialogfeld verlassen m??chten, ohne die ??nderungen zu speichern, klicken Sie auf das X oder bet??tigen Sie die Taste Esc.
3.5.2Ger??tetypen zuordnen
Die KVM
3.5.2.1Zugriff auf das Dialogfeld ???Ger??te???
Bet??tigen Sie die Taste Druck, um die
Klicken Sie auf Setup - Ger??te. Das Dialogfeld ???Ger??te??? wird ge??ffnet.
Abbildung 8: Dialogfeld ???Ger??te???
Wenn die KVM
3.5.2.2Zuweisen des Ger??tetyps
W??hlen Sie die Portnummer im Dialogfeld ???Ger??te??? aus.
Klicken Sie auf ??ndern. Das Dialogfeld ???Ger??t ??ndern??? wird ge??ffnet.
Abbildung 9: Dialogfeld ???Ger??te ??ndern???
W??hlen Sie die Anzahl an Ports aus, die von der gestuften Einheit unterst??tzt werden oder geben Sie die Anzahl ??ber die Tastatur ein. Klicken Sie auf OK.
Die Schritte
Klicken Sie im Dialogfeld ???Ger??te??? auf OK, um die Einstellungen zu speichern.
3.5.3??ndern des Anzeigeverhaltens
Mit dem Dialogfeld ???Men????? kann die Anzeigereihenfolge der Zielger??te ge??ndert und eine Zeitverz??gerung f??r die
3.5.3.1Zugriff auf das Men??fenster
Dr??cken Sie die Taste Druck, um die
Klicken Sie auf Setup - Men??. Das Dialogfeld ???Men????? wird ge??ffnet.
Abbildung 10: ???Men?????, Dialogfeld
3.5.3.2Ausw??hlen der Anzeigereihenfolge f??r Zielger??te
Klicken Sie auf eine der folgenden Schaltfl??chen:
???Klicken Sie auf Name, um die Zielger??te alphabetisch nach Namen zu sortieren.
-oder -
???Klicken Sie auf EID, um die Zielger??te numerisch nach
-oder -
???Klicken Sie auf Port, um die Zielger??te numerisch nach Portnummern zu sortieren.
Klicken Sie auf OK.
3.5.3.3 Ausw??hlen einer Tastenkombination zum Starten der OSCAR- Benutzeroberfl??che
W??hlen Sie im Abschnitt OSCAR aufrufen die Tastenkombination aus, die Sie zum Aufrufen der
Klicken Sie auf OK.
Sie k??nnen eine Zeitverz??gerung einstellen, damit Sie ??ber die Tastatur ein Zielger??t ausw??hlen k??nnen, ohne die
3.5.3.4Einstellen der Zeitverz??gerung
Geben Sie die Sekundenanzahl
Klicken Sie auf OK.
3.5.4Ausw??hlen der Sprache
Im Dialogfeld ???Sprache??? k??nnen Sie die Sprache ??ndern, in der die
Abbildung 11: Dialogfeld ???Sprache???
Bet??tigen Sie die Taste Druck, um die
Klicken Sie auf Setup - Sprache. Das Dialogfeld ???Sprache??? wird ge??ffnet.
W??hlen Sie im Dialogfeld ???Sprache??? die gew??nschte Sprache aus und klicken Sie auf OK.
3.5.5Steuern des
Das
Tabelle 4:
3.5.5.1Festlegen der
1.Bet??tigen Sie die Taste Druck. Das Hauptmen?? wird ge??ffnet.
2.Klicken Sie auf Setup - Flag.
3.Legen Sie eine oder mehrere der folgenden Einstellungen fest:
???W??hlen Sie Name oder EID aus, um die im Flag angezeigten Informationen festzulegen.
-oder -
???W??hlen Sie Anzeigen aus, um das Flag st??ndig anzuzeigen oder Zeit, um das Flag jeweils nur 5 Sekunden lang nach der Auswahl eines Zielger??ts anzuzei- gen.
-oder -
???W??hlen Sie unter Anzeigefarbe die Farbe des Flags aus.
-oder -
???W??hlen Sie Deckend, um das Flag in deckender Farbe anzuzeigen oder Transparent, damit der Desktop durch das Flag sichtbar ist.
-oder -
???F??hren Sie folgende Schritte durch, um die Position des Flags festzulegen:
a.Klicken Sie auf Positionieren.
-oder -
b.Halten Sie die linke Maustaste auf der Titelleiste des Dialogfelds ???Positionieren??? gedr??ckt und ziehen Sie das Dialogfeld an die gew??nschte neue Position.
-oder -
c.Schlie??en Sie das Dialogfeld ???Positionieren???, indem Sie mit der rechten Maustaste klicken.
4.Klicken Sie auf OK, um die ??nderungen zu speichern. Wenn Sie das Dialogfeld verlassen m??chten, ohne die ??nderungen zu speichern, klicken Sie auf das X oder bet??tigen Sie die Taste Esc.
3.5.6Einstellen der l??nderspezifischen Tastatureinstellungen
Standardm????ig sendet die Einheit die Tastatureinstellungen einer
Es k??nnen Probleme auftreten, wenn
Im Dialogfeld ???Tastatur??? k??nnen Sie statt der
Abbildung 12: Dialogfeld ???Tastatur???
3.5.6.1??ndern der l??nderspezifischen Tastatureinstellungen
Bet??tigen Sie die Taste Druck, um die
Klicken Sie auf Setup - Tastatur. Das Dialogfeld ???Tastatur??? wird ge??ffnet.
W??hlen Sie die l??nderspezifische Tastatureinstellung aus und klicken Sie auf OK. Best??tigen Sie die ??nderung im Dialogfeld ???Tastaturwarnung???.
Klicken Sie auf OK, um die ??nderung zu speichern. Wenn Sie das Dialogfeld verlassen m??chten, ohne die ??nderungen zu speichern, klicken Sie auf das X oder bet??tigen Sie die Taste Esc.
3.5.6.2Festlegen der Sicherheitseinstellungen der Einheit
Sie k??nnen einen Bildschirmschoner aktivieren, wenn der Benutzer ??ber einen bestimmten Zeitraum hinweg inaktiv bleibt. Der Benutzer wird von allen verbundenen Zielger??ten getrennt, sobald der Bildschirmschoner startet. Der Bildschirmschoner wird durch einen beliebigen Tastenanschlag oder durch Bewegen der Maus beendet.
Bet??tigen Sie die Taste Druck und die Taste Pause, um den Bildschirmschoner sofort zu aktivieren.
Wenn Sie ein Kennwort einrichten, werden Tastatur und Maus gesperrt, sobald der Bildschirmschoner startet. Wenn Sie eine Taste bet??tigen oder die Maus bewegen, w??hrend der Bildschirmschoner aktiv ist, wird ein
Sollten Sie das Kennwort vergessen, m??ssen Sie sich an den technischen Kundendienst wenden. Kontaktinformationen finden Sie in Anhang 5.4 Technischer Kundendienst auf Seite 47.
3.5.6.3Aktivieren des Bildschirmschoners
Bet??tigen Sie die Taste Druck. Das Hauptmen?? wird ge??ffnet.
Klicken Sie auf Setup - Sicherheit. Wenn ein Kennwort eingerichtet wurde, wird das Dialogfeld ???Kennwort??? angezeigt. Geben Sie Ihr Kennwort ein und klicken Sie auf OK.
Aktivieren Sie das Kontrollk??stchen Bildschirmschoner.
Geben Sie im Feld Wartezeit ein, wie viele Minuten
W??hlen Sie Energie aus, wenn der Bildschirm den Energy
(Optional) Klicken Sie auf Test, um einen
Klicken Sie auf OK.
3.5.6.4Deaktivieren des Bildschirmschoners
Bet??tigen Sie die Taste Druck. Das Hauptmen?? wird ge??ffnet.
Klicken Sie auf Setup - Sicherheit. Wenn ein Kennwort eingerichtet wurde, wird das Dialogfeld ???Kennwort??? angezeigt. Geben Sie Ihr Kennwort ein und klicken Sie auf OK.
Deaktivieren Sie das Kontrollk??stchen Bildschirmschoner.
Klicken Sie auf ???OK???.
Das Kennwort muss sowohl Buchstaben als auch Zahlen enthalten und darf maximal 12 Zeichen lang sein. Es wird zwischen Gro??- und Kleinschreibung unterschieden. Zul??ssige Zeichen sind
3.5.6.5Einrichten oder ??ndern des Kennworts
Bet??tigen Sie die Taste Druck. Das Hauptmen?? wird ge??ffnet.
Klicken Sie auf Setup - Sicherheit. Wenn bereits ein Kennwort eingerichtet wurde, wird das Dialogfeld ???Kennwort??? angezeigt. Geben Sie Ihr Kennwort ein und klicken Sie auf OK.
Doppelklicken Sie auf das Feld Neu.
Geben Sie im Feld Neu das neue Kennwort ein.
Wiederholen Sie das Kennwort im Feld Best??tigen.
Klicken Sie auf OK.
3.5.6.6Deaktivieren des Kennwortschutzes
Bet??tigen Sie die Taste Druck. Das Hauptmen?? wird ge??ffnet.
Klicken Sie auf Setup - Sicherheit. Geben Sie im Dialogfeld ???Kennwort??? das Kennwort ein und klicken Sie auf OK.
Doppelklicken Sie auf das Feld Neu. Lassen Sie das Feld leer und bet??tigen Sie die Eingabetaste.
Doppelklicken Sie auf das Feld Best??tigen. Lassen Sie das Feld leer und bet??tigen Sie die Eingabetaste.
Klicken Sie auf OK.
3.6Verwalten der Aufgaben der Zielger??te ??ber die
Im Dialogfeld ???Befehle??? k??nnen Sie das
Tabelle 5: Befehle zur Verwaltung routinem????iger Aufgaben der Zielger??te
3.6.1Zugriff auf das Dialogfeld ???Befehle???
Bet??tigen Sie die Taste Druck. Das Hauptmen?? wird ge??ffnet.
Klicken Sie auf Befehle. Das Dialogfeld ???Befehle??? wird ge??ffnet.
Abbildung 13: Dialogfeld ???Befehle???
3.6.2Anzeigen der Versionsinformationen
Mit der
Bet??tigen Sie die Taste Druck. Das Hauptmen?? wird ge??ffnet.
Klicken Sie auf Befehle - Versionen anzeigen. Das Fenster ???Version??? wird ge??ffnet. Die Subsystemversionen der Einheit werden in der oberen H??lfte des Fensters aufgef??hrt.
Abbildung 14: Dialogfeld ???Version???
Klicken Sie auf die Schaltfl??che
W??hlen Sie einen
Klicken Sie auf X, um das Fenster
3.6.3Aktualisieren der Firmware
??ber die
Abbildung 15: Dialogfeld ???Aktualisieren???
Bet??tigen Sie die Taste Druck. Das Hauptmen?? wird ge??ffnet.
Klicken Sie auf Befehle - Versionen anzeigen - Aktual. Das Dialogfeld ???Aktual.??? wird ge??ffnet.
Klicken Sie auf Aktual.. Eine Warnmeldung wird angezeigt. Klicken Sie auf OK, um ein Dialogfeld aufzurufen, das den Fortschritt der Aktualisierung anzeigt. Der Aktualisierungsfortschritt wird im Feld Programmiert angezeigt.
3.7Anzeigen der aktuellen Anzeigekonfiguration
Im Dialogfeld ???Konfiguration??? k??nnen Sie die aktuellen Konfigurationen des KVM s2- 0411
Klicken Sie auf Befehle - Konfiguration anzeigen. Das Dialogfeld ???Konfiguration??? wird ge??ffnet. Die aktuellen Systemkonfigurationswerte werden angezeigt.
3.8Anzeigen und Trennen von Benutzerverbindungen
Im Dialogfeld ???Benutzerstatus??? k??nnen Sie Benutzer anzeigen und ihre Verbindung mit Zielger??ten trennen. Der Benutzername (U) wird immer angezeigt. Es ist jedoch m??glich, entweder den Namen oder die
Abbildung 16: Dialogfeld ???Benutzerstatus???
3.8.0.1Anzeigen der aktuellen Benutzerverbindungen
Klicken Sie auf Befehle - Benutzerstatus. Das Dialogfeld ???Benutzerstatus??? wird ge??ffnet.
3.8.0.2Trennen von Benutzerverbindungen
Klicken Sie im Dialogfeld ???Benutzerstatus??? auf den Buchstaben f??r den Benutzer, dessen Verbindung getrennt werden soll. Das Dialogfeld ???Trennen??? wird ge??ffnet.
F??hren Sie einen der folgenden Schritte durch:
???Klicken Sie auf OK, um die Benutzerverbindung zu trennen und zum Dialogfeld ???Benutzerstatus??? zur??ckzukehren.
- oder -
???Klicken Sie auf das X oder bet??tigen Sie die Taste Esc, um das Dialogfeld zu verlassen, ohne eine Benutzerverbindung zu trennen.
Wenn die Benutzerstatusliste sich seit der letzten Anzeige ge??ndert hat, ??ndert sich der Mauszeiger in ein Sanduhrsymbol, w??hrend die Liste automatisch aktualisiert wird. Erst nach abgeschlossener Aktualisierung der Liste werden wieder Tastatur- und Mausein- gaben akzeptiert.
3.8.0.3Zur??cksetzen von Tastatur und Maus
W??hlen Sie Befehle -
Diese Funktion ist nur f??r Computer unter einem Microsoft Windows Betriebssystem vorgesehen. Wenn Sie Tastatur und Maus eines Zielger??ts, das unter einem anderen Betriebssystem l??uft, zur??cksetzen, m??ssen Sie dieses Zielger??t ggf. neu starten.
Bet??tigen Sie die Taste Druck. Das Hauptmen?? wird ge??ffnet.
Klicken Sie auf Befehle - Versionen anzeigen -
Klicken Sie auf Version - Reset.
Es wird eine Meldung angezeigt, dass Maus und Tastatur zur??ckgesetzt wurden.
F??hren Sie einen der folgenden Schritte durch:
???Klicken Sie auf OK, um die Meldung zu schlie??en. - oder -
???Klicken Sie auf das X oder bet??tigen Sie die Taste Esc, um das Dialogfeld zu verlassen, ohne den
3.9Scannen des
Im
3.9.1Hinzuf??gen von Zielger??ten zur
Klicken Sie auf Setup - Scan. Das Dialogfeld ???Scan??? wird ge??ffnet
.
Abbildung 17: Dialogfeld ???Scannen???
Das Dialogfeld enth??lt eine Auflistung aller mit der Einheit verbundenen Zielger??te. F??hren Sie einen der folgenden Schritte durch, um Zielger??te zum Scannen auszuw??hlen:
???Aktivieren Sie das Kontrollk??stchen neben den Zielger??ten, die gescannt werden sollen.
-oder -
???Doppelklicken Sie auf den Namen oder Port eines Zielger??ts.
-oder -
???Bet??tigen Sie die Taste Alt und geben Sie die
Geben Sie in das Feld Zeit die Anzahl der Sekunden (von 3 bis 255) ein, bevor das n??chste Zielger??t in der Liste gescannt wird.
Klicken Sie auf OK.
3.9.2Entfernen eines Zielger??ts aus der
F??hren Sie einen der folgenden Schritte durch:
???Deaktivieren Sie im Dialogfeld ???Scannen??? das Kontrollk??stchen neben dem Zielger??t, das entfernt werden soll.
-oder -
???Doppelklicken Sie auf den Namen oder Port des Zielger??ts.
-oder -
???Bet??tigen Sie die Umschalttaste + Entf, um das ausgew??hlte Zielger??t und alle darunter aufgelisteten Eintr??ge zu entfernen.
-oder -
???Klicken Sie auf die Schaltfl??che L??schen, um alle Zielger??te aus der Scan- Liste zu entfernen.
Klicken Sie auf OK.
3.9.3Starten des
Klicken Sie auf Befehle. Das Dialogfeld ???Befehle??? wird ge??ffnet.
Abbildung 18: Dialogfeld ???Befehle???
Aktivieren Sie im Dialogfeld ???Befehle??? das Kontrollk??stchen Scan aktiviert. Der
Klicken Sie auf X, um das Fenster ???Befehle??? zu schlie??en.
3.9.4Abbrechen des
F??hren Sie einen der folgenden Schritte durch:
W??hlen Sie ein Zielger??t aus, wenn die
- oder -
Wenn die
3.10Diagnosetests am
Die Integrit??t Ihres
Das Dialogfeld ???Diagnosetests??? wird ge??ffnet. In der oberen H??lfte des Dialogfelds werden die
Abbildung 19: Dialogfeld ???Diagnosetests???
Nach Beendigung jedes Tests wird links neben jeder Position entweder ein Symbol f??r einen fehlerfreien (gr??ner Kreis) oder einen fehlerhaften Test (rotes X) angezeigt. In der folgenden Tabelle werden alle Tests n??her beschrieben.
Tabelle 6: Einzelheiten der Diagnosetests
Tabelle 6: Einzelheiten der Diagnosetests
3.10.1Starten der Diagnosestests
Klicken Sie auf Befehle - Diagnosetests. In einer Warnmeldung werden Sie darauf hingewiesen, dass alle Benutzerverbindungen getrennt werden.
Klicken Sie auf OK, um die Diagnosetests zu starten.
Alle Benutzer werden getrennt und das Dialogfeld ???Diagnosetests??? wird angezeigt.
Nach jedem Test wird ein Symbol f??r einen fehlerfreien (gr??ner Kreis) bzw. fehlerhaften Test (rotes X) angezeigt. Die Tests sind beendet, wenn das Symbol f??r den letzten Test angezeigt wird.
4 Terminalbetrieb des Computers
4.1Konsolenmen??
Jede Einheit kann auf Einheitenebene durch das Konsolenmen?? konfiguriert werden, indem der Konfigurationsport an der Ger??ter??ckseite verwendet wird. Der Zugriff auf alle Terminalbefehle ist ??ber ein Terminal oder einen Computer, auf dem eine Terminal- Emulationssoftware ausgef??hrt wird, m??glich.
4.1.1Konfigurieren des Netzwerks ??ber das Konsolenmen??
Wenn Sie die Einheit einschalten, f??hrt diese ca. 1 Minute lang eine Initialisierung durch. Bet??tigen Sie nach Abschluss der Initialisierung eine beliebige Taste am Terminal oder am Computer, auf dem die
Das Konsolenhauptmen?? wird ge??ffnet. Geben Sie 1 ein, und bet??tigen Sie die Eingabetaste, um auf die Option f??r die Netzwerkkonfiguration zuzugreifen. Das Men?? ???Network Configuration??? wird ge??ffnet
Abbildung 20: Men?? ???Network Configuration???
Geben Sie zum Einstellen der Netzwerkgeschwindigkeit 1 ein, und bet??tigen Sie die Eingabetaste. Richten Sie die Netzwerkverbindung nach M??glichkeit manuell ein, anstatt auf die dynamische Anpassung der Verbindung zu vertrauen (Auto-
Geben Sie eine 2 ein und bet??tigen Sie die Eingabetaste, um festzulegen, ob Sie eine statische oder eine DHCP (Dynamic Host Configuration
Statische
W??hlen Sie die ??brigen Optionen des Men??s ???Network Configuration??? aus, um die Konfiguration der Einheit f??r
Geben Sie 0 (Null) ein, und bet??tigen Sie die Eingabetaste, um zum Konsolen- hauptmen?? zur??ckzukehren. Die Einheit wird dann neu gestartet.
4.1.2Weitere Optionen im Konsolenhauptmen??
Neben der Option ???Network Configuration??? stehen Ihnen im Konsolenhauptmen?? der Einheit folgende weitere Optionen zur Verf??gung: Security Configuration (Sicherheits- konfiguration), Firmware Management, Enable Debug Messages
4.1.2.1Security configuration (Sicherheitskonfiguration)
Console Password (Kennwort der Konsole): Aktivieren oder deaktivieren Sie das Kenn- wort ??ber die Sicherheitsfunktion der Konsole (zum Zugriff wird ein Administratorkonto ben??tigt). Geben Sie ???Help??? ein, falls sie Ihr Kennwort vergessen haben. Sie erhalten einen Schl??ssel zur einmaligen Verwendung, den Sie an den technischen Kundendienst weitergeben. Vom technischen Kundendienst erhalten Sie ein Kennwort zur einmaligen Verwendung, mit dem der Zugang zum seriellen Port m??glich ist.
4.1.2.2Firmware Management
Dieses Men?? enth??lt die Option
4.1.2.3Enable debug messages
Diese Men??option aktiviert die Statusmeldungen der Konsole. Sie sollten Debug- Meldungen nur aktivieren, wenn Sie vom technischen Kundendienst dazu angewiesen wurden, da diese Funktion die Leistung deutlich mindern kann. Dieser Modus kann durch Bet??tigen einer beliebigen Taste beendet werden, wenn Sie die Anzeige der Nachrichten nicht mehr ben??tigen.
4.1.2.4Restore Factory Defaults (Standardeinstellungen wiederherstellen)
Diese Men??option setzt alle Optionen der Einheit auf die Standarteinstellungen zur??ck.
4.1.2.5Reset Appliance (Einheit zur??cksetzen)
Mit dieser Option k??nnen Sie die Einheit neu starten (Warmstart).
4.1.2.6Exit (Beenden)
Mit dieser Men??auswahl kehren Sie wieder zur Eingabeaufforderung zur??ck.
5 Anh??nge
5.1
5.1.1Aktualisieren der KVM
??ber die Funktion
F??r die Aktualisierung ben??tigen Sie Folgendes
???Ein Zielger??t, auf dem eine Terminalsoftware betrieben wird
???Einen verf??gbaren seriellen Port
???Ein serielles Kabel, welches das Zielger??t mit der Einheit verbindet.
???
5.1.2Aktualisieren einer neuen
Aktuelle
Schlie??en Sie einen Computer mit einer
Schalten Sie die Einheit ein, wenn sie nicht schon eingeschaltet ist. Dr??cken Sie nach ca. einer Minute eine beliebige Taste, um das Konsolenhauptmen?? aufzurufen.
Das Konsolenhauptmen?? wird ge??ffnet. W??hlen Sie die Option ???Firmware Management??? aus. Die aktuelle
Geben Sie 1 ein, und bet??tigen Sie die Eingabetaste, um den
Geben Sie die
Geben Sie den Namen der
Best??tigen Sie den
Die Einheit pr??ft, ob die geladene Datei g??ltig ist. Sie werden nun aufgefordert, die Aktualisierung zu best??tigen. Geben Sie y bzw. yes ein und best??tigen Sie mit der Eingabetaste.
Die Einheit beginnt mit der
Nach Abschluss der Aktualisierung wird eine Best??tigungsmeldung angezeigt.
5.1.3Aktualisierung der
Die
5.1.3.1Gleichzeitiges Aktualisieren mehrerer
Bet??tigen Sie die Taste Druck. Das Hauptmen?? wird ge??ffnet.
Klicken Sie auf Befehle >
Abbildung 21: Dialogfeld
Auf einen oder mehrere Modultypen klicken, die aktualisiert werden sollen. Klicken Sie auf Aktual..
Das Dialogfeld f??r die
5.1.3.2Individuelle Aktualisierung von
Bet??tigen Sie die Taste Druck. Das Hauptmen?? wird ge??ffnet.
Klicken Sie auf Befehle > Versionen anzeigen. Das Dialogfeld f??r die
Abbildung 22: Dialogfeld
Klicken Sie auf
Abbildung 23: Dialogfeld
W??hlen Sie einen
Klicken Sie auf die Schaltfl??che Firmware laden. Das Dialogfeld
Klicken Sie auf OK, um die Aktualisierung zu starten und zum
W??hrend einer Aktualisierung ist die Statusanzeige des
5.1.4Reparieren von besch??digter Firmware
In seltenen F??llen kommt es vor, dass die Firmware nach einer
???
???
???Name der
5.1.4.1Reparieren von besch??digter Firmware
Schlie??en Sie die Einheit (mithilfe eines Verbindungskabels oder eines Hubs) an das
??ndern Sie den Namen der
Die
5.2
Die folgenden Informationen bieten eine kurze Einf??hrung in die verschiedenen Aspekte der Verbindungsmedien ein. Die Leistungsf??higkeit Ihres
5.2.1
???CAT
???CAT
???CAT
5.2.2Kabelnormen
Es gelten zwei unterst??tzte Kabelnormen f??r
Tabelle 7:
5.2.3Kabelinstallation, Kabelwartung und Sicherheitshinweise
Im Folgenden werden wichtige Sicherheitshinweise aufgelistet, die bei der Installation und Wartung von Kabeln beachtet werden sollten:
???Alle CAT 5 Kabel sollten jeweils nur ??ber eine maximale L??nge von 10 Metern verlegt werden. Manche Kabel k??nnen auch auf einer gr????eren L??nge verlegt werden.
???Behalten Sie die Verdrillung der Paare bis zum endg??ltigen Anschluss bei; oder l??sen Sie die Verdrillung um h??chstens 1,25 cm. Entfernen Sie nicht mehr als 2,50 cm der Ummantelung beim Anschluss.
???Wenn das Kabel gebogen werden muss, sollte eine leichte Biegung mit nicht mehr als 2,54 cm Radius verlegt werden. Durch starkes Biegen oder Knicken des Kabels kann das Kabelinnere permanent besch??digt werden.
???Fassen Sie die Kabel mit Kabelbindern bei geringem bis mittlerem Druck zusammen. Binden Sie die Kabelbinder nicht zu fest zusammen.
???Stellen Sie bei Bedarf mithilfe von Kontaktbl??cken,
???CAT
?????berpr??fen Sie immer jedes installierte Segment mit einem Kabelpr??fer. ???Toning??? allein ist keine ausreichende ??berpr??fung.
???Installieren Sie die Anschlussbuchsen immer so, dass kein Staub oder andere Verschmutzungen auf die Kontakte gelangen k??nnen. Die Kontakte der Anschlussbuchse sollten auf gerade abschlie??enden Einbauplatten nach oben und auf
???Lassen Sie immer etwas zus??tzlichen Durchhang in den Kabeln; verstauen Sie die gerollten Kabel ordentlich in der Decke oder an einer anderen gesch??tzten Stelle. Lassen Sie eine
???Entscheiden Sie sich vor Arbeitsbeginn f??r die Kabelnorm 568A oder 568B. Verkabeln Sie alle Anschlussbuchsen und
???Befolgen Sie stets die ma??geblichen Brandschutz- und Geb??udevorschriften. Stellen Sie sicher, dass alle Kabel, die in einer Brandmauer verlegt wurden, die Brandschutzbedingungen erf??llen. Verwenden Sie ggf. Plenumkabel.
5.3Technische Daten
Ports der Zielserver
Tabelle 8: Produktspezifikationen
5.4Technischer Kundendienst
Unser technischer Kundendienst steht Ihnen jederzeit f??r Fragen hinsichtlich Installation und Betrieb Ihres Produkts von Fujitsu Siemens zur Verf??gung. Verfahren Sie zur schnellstm??glichen Probleml??sung wie folgt: Sehen Sie im entsprechenden Abschnitt der Bedienungsanleitung nach, ob das Problem mit den vorgeschlagenen Abhilfema??nahmen gel??st werden kann. Besuchen Sie unsere Webseite unter
5.4.1Vor dem Anruf
Stellen Sie vor dem Anruf sicher, dass Sie folgende Schritte durchgef??hrt haben, um das Problem zu beheben:
?????berpr??fen Sie alle Kabel, um sicherzustellen, dass sie ordnungsgem???? angeschlossen sind.
?????berpr??fen Sie die Netzschalter, um sicherzustellen, dass das System und alle optionalen Ger??te eingeschaltet sind.
???Verwenden Sie die Angaben zur Fehlerbehebung in Ihrer Systemdokumentation sowie die Diagnosehilfen des Systems.
???Besuchen Sie die Fujitsu Siemens
Sie k??nnen viele Probleme eigenst??ndig beheben, indem Sie den Anweisungen zur Fehlerbehebung folgen, die Fujitsu Siemens in der