PCS7 / TM (WinCC / TM)
V2.02
Product Information
This product information is more binding than current statements in Manuals and in the
1 General Information
Scope of delivery
This CD contains the following components for
???TELEPERM M channel DLL
???Image blocks in TELEPERM M NORA representation:
???Image blocks in a representation similar PCS7: PCS7/TM_OCX (PCS7)
???Documentation and product information in pdf format - see chapter 4
???TELEPERM M tools such as ???establish connection(*)???, ORPA import, block import, message gen- erator
???Configuring tools TM_SmartTools including description (*)
(*) Only with version 5
The scope of delivery does not contain:
???System software WinCC, V5.0/ SP2+HF7, or
???Operating system Windows NT, 4.0, including Service Packs
2 What???s new ?
2.1CD content in general
Starting the program Setup.exe in the root directory of the CD will identify the installed WinCC version and branch to the corresponding version???s directory of the CD (PCS7_Version_4 or PCS7_Version_5). For further information see chapter 3.3. If a valid version of WinCC cannot be identified the program Setup.exe will be finished after a message box has been given out .
Under the directory PCS7_Version_5 you find in addition to the current version of the TELEPERM M channel V2.02 also the older version V2.01 under the corresponding
2.1.1TM_SmartTools
With Version_5 so called TM_SmartTools are delivered which support the configuration. These pro- grams are delivered free of charge and without commitment. They may be copied to any directory of the hard disk, preferably <...>\Siemens\TM_Werkzeuge and initialised from there. A short description of the tools is delivered under the corresponding directory of the CD.
2.2TELEPERM M channel
It is mandatory to install the TELEPERM M channel after the installation of the components for PCS7 or WinCC. If WinCC is installed later the TELEPERM M channel has to been reinstalled again.
2.2.1Modifications vs. Version V2.01
The following problems have been eliminated:
???Acceleration of the Message Generator
Because of using a new function within WinCC the generating procedure could be accelerated.
The following new functions have been implemented:
With the current version V5.0/SP2 + HF7 WinCC delivers a new function concerning redundancy:
???Switchover to the Master Server after CS 275 Coupling
When a server which is the master server for one or more
terminated.
???Switchover of the Servers after CS 275 Coupling Fault
When at least one connection to a subsidiary AS fails the
To activate these functions it is necessary to make an entry in the registry of the servers. This entry can be made by
Both files are stored in the CD directory <...>\PCS7_Version_5\Redundancy.
???Channel Diagnosis
Hence the TELEPERM M Channel DLL uses the WinCC Channel Diagnosis. It is initiated via \Simatic\WinCC\Tools\Channel Diagnosis. You should select the following basic configuration:
2.2.2Restrictions
???Trends by Means of Measurement Points (function of
This function will no longer be available from V5.0 onwards.
???Creating the WinCC Tag Management
The WinCC Tag Management (variable under connections) may solely be created via "TELEPERM M Import blocks" wizard provided.
???Order of Simultaneously Occurring Messages in Alarm Logging
Simultaneously occurring messages of a function block (alarm, warning, tolerance) are given out in order of the message numbers (WinCC system feature).
2.3
2.3.1Modifications vs. Version V2.01
In addition to the present image blocks in TELEPERM M NORA representation we deliver a set of renovated image blocks. They have identical display with the present ones, additionally they are sup- plemented with the properties ???Modus??? (display mode group/ loop), ???Farbe_*??? (color of bars and digital values). For details see description ???TELEPERM NORA renoviert.pdf???. The contractions G_ or K_ in the OCX names have been dropped.
These blocks can be installed on demand by checking the component
2.4
2.4.1Modifications vs. Version V2.01
None.
3 General Information About the Installation
Requirements
The software products that are contained on this CD are released under WinCC, Version 5.0/SP2+ HF7, or PCS7, Version 5.2, and Windows NT, 4.0 + SP5. The hardware requirements are listed in the associated documents (Vertriebsfreigabe zu PCS7/TM, V2.02, in TELEPERM M aktuell).
With transition to PCS7, V5.2, the C partition of the used computer must have a memory of at least 4 GByte.
Please observe the Chapter 5 ???Version Interdependencies??? in this document.
3.1Operation system Windows NT, 4.0, Upgrading to SP5
Note: The PCS 7/TM CD does not contain the operation system Windows NT, 4.0, or any Service Packs (SP).
Language variants of the SP must be used according to the selection in the base installation.
To install the NT SP5, load the corresponding Setup.exe. Overwrite older files when the system asks for file versions during the installation process. Please observe the notes etc. of the SP5.
3.2Content of the CD
The software components for PCS 7/TM and the documents are supplied on
-Dok
-Siemens
-SW
-Winnt.400
Contains the product information and all the descriptions in pdf format (see chapter 4)
Contains the channel components in an uncompressed form, 2 example projects as well as a part of a project and some Scripts and functions
Contains the installation programs for channel and image blocks (and additional products)
Contains the old driver software for the N_AT module
3.3Installation using the Common Installation Mask
This CD is equipped with an ???Autorun??? facility that automatically starts the installation mask when the CD is inserted (provided that the computer has been set up for this feature). If this selection has not been made in your computer, the installation mask can also be initiated by
Using the common installation mask it is sufficient to select all components to be installed. When WinCC/TM is selected, the check is automatically set for the
stallation mask solely concerns the comments; the language of the installation proper must be speci- fied separately.
Any old installation of the components that are to be installed will be removed at the beginning.
Each installation procedure may be started manually and separately using the file setup.exe in the corresponding
??? It should be taken into consideration that during all installation procedures WinCC must be terminated.
3.4Installation of the TELEPERM M Channel DLL and Tools
The TELEPERM M
-
-Client/ server system: in all servers, in the clients merely the TELEPERM M.chn channel and all files of the Telpm*.lng. type.
-
The authorisation is supplied on a separate floppy disk.
Manual installation:
To install the TELEPERM M channel DLL and tools, please branch to the SW\ Kanal directory and invoke Setup.exe there. From now on, the installation procedure will be prompted. The default setting of <LW> is the installation drive of WinCC. This setting must not be changed.
If not already done explicitly at the beginning any existing installation will be removed during this proc- ess.
???If it does not yet exist, the authorization must be transferred to the PCS 7 installation drive. To do this, please insert the authorization floppy disk into the drive and
???The installation is thus performed. Further information can be found in the
<LW>:\Siemens\TM_Werkzeuge\Liesmich.txt file or in the documentation.
???The files Ydata220.dat and Ydata230.dat that are included in the delivery contain the data that is relevant for the W startup, and must not be modified.
???Depending on the installed authorization, this software version permits communication with the following automation systems:
-AS 230/ AS 235/ AS 235H/ AS 388/ AS 488 AS 215
AG 150U / AG 155U
-AS 220S/ AS 220H
(See also Chapter 3.7 "Necessary Licenses")
???Startup features:
The AS systems are marked as failed during the entire duration of the startup phase. Furthermore, all AS systems must be operational on the bus at the startup time.
3.4.1Installation of the N_AT/N_PCI driver
If the N_AT driver is required, it can be installed via a separate installation procedure
3.4.2What to do after the Installation ?
After the successful installation all delivered TM configuration tools, i.e. wizards, should be imported with the
This is not necessary if the Split Screen Wizard is executed (recommendation); herewith the current TM configuration tools are copied into the project and are available there.
3.5Installation of the
The image blocks in TELEPERM
The authorization is supplied on a separate floppy disk.
This package must be installed in all computers that shall be used for operator communication and visualization.
-
-
-Server, if it is operator station at the same time.
3.5.1Procedure of the manual installation
???There is an older version of
Uninstall these two objects.
???To install the image blocks in TELEPERM M NORA representation branch to the SW\ OCX_TM directory and invoke Setup.exe there. The rest of the installation procedure will be prompted. Also install the VB6_DLL (in the same setup).
If not already done explicitly at the beginning any existing installation will be removed during this process.
The "Prototype images" option can be used for copying these images into the corresponding WinCC folder from where they will be copied into the project when the Split Screen Wizard executed.
???The authorization must be transferred to the same drive as the other PCS7 authorizations. To do this, please insert the authorization floppy disk into the drive and
Of course, this step is only necessary if an authorization has not yet been installed.
The image blocks in TELEPERM M NORA representation are now ready for the configuration in the
3.5.2Revision levels
???TelepermMOCX.dll V1.0.0.3
Image blocks (OCX) for the five standard function blocks TRAS, TRB, TRES, TRM and TRR are pro- vided for the operation with AS 215. Their utilization is subject to change.
3.5.3What to do after the installation ?
After the successful installation all optionally installed prototype images may be copied with the
3.6Installation of the
The image blocks in a
The authorization is supplied on a separate floppy disk.
This package must be installed in all computers that shall be used for operator communication and visualization:
-
-
-Server, if the server is operator station at the same time.
3.6.1Procedure of the manual installation
???There is an older version of
Uninstall these two objects.
???To install the image blocks in
Any existing installation will be removed during this process.
The "Prototype images" option can be used for copying these images into the corresponding WinCC folder from where they will be copied into the project when the Split Screen Wizard executes.
???The authorization must be transferred to the same drive as the other PCS7 authorizations. To do this, please insert the authorization floppy disk into the drive and
Of course, this step is only necessary if an authorization has not yet been installed.
The image blocks in
Note: Some image blocks in
3.6.2Revision levels
3.6.3What to do after the installation ?
After the successful installation all optionally installed prototype images may be copied with the
3.6.4Simultaneous Utilization of PCS7/TM-OCX( NORA) and
Both image block types can be used simultaneously in a computer. However, the package of the im- age blocks in TELEPERM M NORA representation must first be installed.
If one of the simultaneously installed packages shall be removed, we strongly recommend to remove both packages and to reinstall the one that shall remain.
Simultaneous utilization of the prototype images of both image types is not possible because of identity of the objects??? names.
3.7Necessary TM Licenses (Authorization)
Authorizations are installed in the <LW>:AX NF ZZ directory.
Depending on the employed channel, the following authorization must be stored there:
TELEPERM M channel DLL CS 275/ L2:
???AS 23x, AS 488, AS 215, AG 150U
???AS 220 and AS 23x, AS488, AS 215,
This authorization must be installed in all computers that communicate with an AS.
If the installed channel and the authorization are not compatible with each other, a box appears during runtime that states this incompatibility. The License.log file in the <LW>:\Siemens\WinCC\Diagnose directory tells you which license is required for the installed channel.
Image blocks
???The authorization A7TMFP50 is uniformly required for all image blocks.
It must be installed on each PC where operator input and visualization is required
3.7.1Upgrade from WinCC/TM, V1.0x, to PCS7/TM, V2.0x
For this upgrade we offer the Upgrade package V2.0.
Changing from PCS7/TM, V2.00 to V2.01, or V2.01 to V2.02 the TM licences are not affected.
Important note:
Upon the migration from version V1.0x ... V1.05 to version V2.0 you will irrevocably lose the authorization for the previous version.
We recommend to perform the migration of the authorization prior to the installation of PCS7/TM. The migration requires the following preconditions to be fulfilled:
???You possess a single license or a copy license for WinCC/TM; V1.0x on an authorization floppy disk or in your computer.
???You have purchased an upgrade license to PCS7/TM V2.0 (referred to as "authorization upgrade" in the text below).
To upgrade the software from version V1.0x, use the following procedure:
1.The "old authorization" must be on the associated "old authorization floppy disk???. If necessary, you must first transfer this authorization from your computer onto the "old authorization floppy disk".
2.Insert the "authorization floppy disk - upgrade??? and invoke the "AuthorsW" program via the start bar under Simatic > AuthorsW. If "AuthorsW" has not been installed in your computer, you must carry out the installa- tion from the CD ("Setup.exe" in the Authors / Disk 1 directory). The "Extras" menu contains a menu item "Upgrading guideline???. This guideline can support you during upgrading.
3.Select the "Authorization management" tab. Select the menu item "Upgrading..." from the "Authorization??? menu.
4.Select the upgrade program from the dialog that is opened subsequently. You will then be prompted to insert the authorization floppy disk of the old authorization (V1.0x). Please follow the instructions on the screen and insert the "Authorization floppy disk - upgrade" when you are prompted to do so.
5.Upgrading will be terminated when the new authorization V2.0 is activated on the "Authorization floppy disk - upgrade".
6.The new authorization can now be transferred to your computer during the setup or using "AuthorsW???.
4 Documentation
Revised descriptions in pdf format are supplied in the dok\ directory on the delivery CD. Their contents replace the printed descriptions.
???PCS 7/TM (Name of the document: WinCC/TM))
Description of the TELEPERM M channel and the tools order no.
???PCS
Description of the image blocks in TELEPERM M NORA representation order no.
???PCS
Description of the image blocks in
???
Description of the image blocks in symbol representation
???
Description of the image blocks for AS 215
???MKS
Description of the single bit acknowledgement of the MKS block
???TELEPERM NORA renoviert
Description of the ???integrated??? image blocks in TELEPERM M NORA representation
The Acrobat Reader1 is provided (ar40deu.exe) for reading the pdf files.
(1"Acrobat?? Reader Copyright ??
???TM_SmartTools
The description of the TM_SmartTools is stored in the corresponding directory as a file in Word- pad format.
5 Version Interdependencies
6 Conversion of a PCS 7/TM Project from WinCC 4.0x to 5.x
This conversion requires special knowledge and should be realized by appropriate qualified personal only. Following are the steps to be considered in short.
This explanation is valid for the language selection ???German???.
A project that was created under WinCC 4.02 or an earlier version must first be converted for PCS7/ WinCC 5.x. The procedure that is described in the WinCC product information ("ReleaseNotes") must basically be used. Observe this procedure.
To show this clearly, we point out the following mandatory steps:
???Open the project with WinCC, V5.x
???Edit the Split Screen Wizard
With
With
???Across all servers with a total of 16 areas.
???
Recommendation for the selection of the area overview in clients of
The first variant should be selected in a system of no more than a total of 16 areas. The second variant should be preferred in systems of more than 16 areas.
???Edit the Alarm Logging Wizard
???Convert the graphic images
???Convert the global library
???Convert the project library
???Open tag logging and save to terminate.
???Open the Picture Tree Manager and save to terminate it.
It can happen upon the migration of projects from WinCC version V4.0x to WinCC version 5 that an OCX in a graphic image is either not recognized ("unknown object") or that the properties are no longer visible in the Graphics Designer. The corresponding OCX must newly be placed in ei- ther case. Failure to do so will produce an error message when the Picture Tree Manager is saved.
???Terminate WinCC and restart it afterwards.
???Start DynWizEdit. Read all four TELEPERM M wizards ("TELEPERM M Verbindung einrich- ten.wnf", ???TELEPERM M Import ORPA.wnf???, ???TELEPERM M Import Bausteine.wnf??? and ???TELEPERM M Meldungen.wnf???) from the Siemens\WinCC\BSTMapper directory, and create a
CWD file.
??? When activating the Split Screen Wizard (from the current version V2.02) the current wiz- ards are already included in the project !
???Implementing the changes in the group display routing requires the variable management and the ORPA definitions (structures) to be deleted and newly to be created. All TELEPERM M messages must first be cleared.
???To implement the changes of the message generator, you must first start it and clear all existing TELEPERM M messages. Next, you must start the message generator again and create default message texts.
???
Using this function requires messages from function blocks (via status word) to be allocated to an area in the sense of the Picture Tree Manager.
Manual allocation:
Each message concerned must be provided with an area name in the "Area" message block.
Allocation via EXCEL list and TM_RangMeld:
To make this allocation more convenient and easier to reproduce, it can be performed using the TM_RangMeld program that is provided on the WinCC/TM CD and an EXCEL list that must be created beforehand. See the corresponding description on the CD.
Allocation via exporting/importing with the Alarm Logging Editor:
Another possibility is the export of the relevant messages (set the selection accordingly) in Alarm Logging into a file, editing the messages such that an area name is entered in the "Block:2" (= area) column, and removing the associated TextID ("TextID 2") in the same line. Next, reimport the file in Alarm Logging.
???The converted project must be a
Transition from WinCC, V5.0, to V5.0/SP2 (PCS7, V5.2)
Special measures are not required for this transition. The Es WinCC wizards Split Screen Wizard and Alarm Logging Wizard should always be activated. This is to guarantee that modifications and en- hancements will be transferred into the project.
7 Creating a new PCS 7/TM project
This explanation is valid for the language selection "German". Please observe the WinCC/ PCS 7 product information ("ReleaseNotes")..
7.1Creating a Project for
???Create the project as a
It must be noted here that the server name and the project name in the
???Edit the Split Screen Wizard
???Edit the Alarm Logging Wizard
???Insert new driver for the TELEPERM M channel in the variable management.
???Start DynWizEdit and read all 4 TELEPERM M wizards ("TELEPERM M Verbindung einrich- ten.wnf", ???TELEPERM M Import ORPA.wnf???, ???TELEPERM M Import Bausteine.wnf??? and ???TELEPERM M Meldungen.wnf???) from the Siemens\WinCC\BSTMapper directory and create CWD file.
Note: When activating the Split Screen Wizard (from the current version V2.02) the current wizards are already included in the project !
???Execute wizard "TELEPERM M Verbindung einrichten" and define the desired connections.
???Execute ???Import TELEPERM M ORPAs??? once or twice (user or TML blocks).
???Please do not forget that importing so called field blocks (GA, GB, etc.) always only 1 element is generated; additional elements have to be defined manually before executing the import of TELEPERM M blocks.
???Execute ???Import TELEPERM M blocks???.
???Execute ???TELEPERM M messages??? and create default message texts.
???
Using this function requires messages from function blocks (via status word) to be allocated to an area in the sense of the Picture Tree Manager.
Manual allocation:
Each message concerned must be provided with an area name in the "Area" message block.
Allocation via EXCEL list and TM_RangMeld:
To make this allocation more convenient and easier to reproduce, it can be performed using the TM_RangMeld program that is provided on the WinCC/TM CD and an EXCEL list that must be created beforehand. See the corresponding description on the CD.
Prior to this step, you should expediently create the topmost area level in the Picture Tree Man- ager.
???If necessary, the TELEPERM M message class must be included in the selection of the individual message windows.
???Next, all further configuration steps are performed.
???Once the configuration has been completed, a package for the operation from a
7.2Creating a
???Create the project as a
???Edit the Split Screen Wizard
Selection between two area overviews is possible in the
???Across all servers with a total of 16 areas.
???
Recommendation for the selection of the area overview in clients of
The first variant should be selected in a system of no more than a total of 16 areas. The second variant should be preferred in systems of more than 16 areas.
???Edit the Alarm Logging Wizard
???Import the server packages
???Create the operator input privileges in the User Administrator
???Define the standard server for alarm logging
This definition must be made to store the operator communication messages of a
???The connection to the servers is established under Serverdata by loading the packages.
8Bus Parameters for PROFIBUS TM System Bus on ASx88/TM and WinCC
Highest station address
Local device address
Baud rates (index)
Slot time
Quiet time
Setup time
Minimum station delay time
Maximum station delay time
Token rotation time
GAP factor
Call repetitions
Ready time
Idle time 1
Idle time 2
1,5 Mbits/s
3000
0
240
980
150
min. 90000 *)
30 **)
1
150
515
980
???The PROFIBUS bus parameters for WinCC are specified in the
???*) Use the following formula to calculate the Ttr parameter, and enter it: Ttr (l2_ttr) = 9000 * [number of active
Note: The factor 9000 in the formula is only valid for a baud rate of 1.5 Mbits/s.
???**) For the baud rate of 1.5 Mbits/s, the default value of the gap factor is 30 ??? 50. Entering a smaller value may be necessary in exceptional cases.
???All specified bus parameters are tuned to the baud rate of 1.5 Mbits/s. Any change/optimization requires a deep knowledge of the PROFIBUS standard.
???The bus parameters for all TELEPERM components (e.g. OS525 and PROGRAF AS) on the PROFIBUS TM system bus must be selected accordingly.
9 Important Notes
9.1Permissible Installations
Software products that are not mandatory for the operation of PCS7 must not be installed in servers, clients or
9.2Time in the Bus System
Time synchronization is mandatory in the bus system. Consistent message processing is not possible otherwise. A PCS7/TM OS should be time master, the time of the other PCs should be synchronized with the PCS7 tool DCS77 client.
9.3Logical Connections
Creating logical connections with the same CS275 address is not permitted. The name of a logical connection must not contain any special character (including "_"). This means that AS_103 is not per- mitted.
9.4ZKS Blocks
The access to ZKS blocks has not been implemented.
9.5C Scripts
???General: We expressively want to point out again here that the general conventions of the pro- gramming language C must be observed when scripts are employed. Failure to do so may cause unpredictable reactions that can strongly affect proper operator communication and visualization.
???When connecting a graphical object with a script only the value of the object is transferred. This value will be signed ???valid??? independent of the state of the value.
???When dynamising the property ???tagname ??? of an OCX it should be taken care that this it not car- ried out cyclically.
9.6Quantity Framework
When project images are configured in WinCC/TM, the capacity utilization of the bus system and of the subordinate automation systems must be taken into consideration in addition to the specifications of the permissible mixed quantity framework / see TELEPERM M aktuell 1998/011/. A server may be charged with max. 600 variables/ second.
9.7PROGRAF AS+
Utilization of PROGRAF AS+ data for the function ORPA import or block import as a function of the employed automation system:
1)Can be generated with theTM_SmartTool genBST.
2)On demand. Please contact your Siemens sales partner.
9.8Manipulations in the AS
With manipulations in the AS it must be ensured that - depending on the measure - messages etc. may be lost via status message frames and/ or MKS message frames. Setting the AS in a defined state first is therefor expedient.
9.9S Strings in TML Blocks
Only the first character of a parameter of the "S" type in a TML block can be read.
9.10 Structures of Field Blocks (GA, GB, etc)
Only one structure definition is possible for each field type. All configured fields in the AS must show at least this length.
The export of PROGRAF AS merely creates the first element. Any other element must be added manually. The 0th element must also be created manually if it shall be read.
A length between 1 and 256 is possible.
9.11 Fonts
"Large fonts" must not be selected in the screen properties.
9.12 Number of Variables Under a Connection
A maximum of 64k variables may be created under an AS connection.
9.13 Troubleshooting Tips
??? License Problems at Runtime
Frequently, the TELEPERM M hotline is notified of license problems that are signalled during runtime after the TELEPERM M channel has been installed. In all cases this is due to the fact that an authori- zation was purchased for the operation with AS 23*, while version ???AS 23* and AS 220" was specifi- cally selected during the installation process. The problem is eliminated when installation is repeated correctly.
Version and AS type of the TELEPERM M channel are stored in the registry code HKEY_LOCAL_MACHINE\Software\Siemens AG\WinCC_TM under "Version" or
This information can be retrieved via the program TM_Info (in the TM_Werkzeuge directory).
??? Missing Texts in Image Blocks
Likewise, customers frequently report that texts are not displayed in the image blocks during runtime after the
??? Message of the Teleperm M Class
For various function blocks, the TELEPERM M message generator creates messages of the TELEPERM M class. Since this class is obviously not contained in the prefabricated WinCC message images, they must be incorporated by the configuring engineer if this is required.
9.14 "Init" Button in System Parameter of the TELEPERM M channel/ CS 725
This button may not pressed at runtime in any case.
9.15
The coupling
9.16
Device number 0 is reserved on all CS 275 busses and therefore may not be used.
9.17 TELEPERM M in Intranet or Internet
Please refer to the following sites for current information about TELEPERM M, especially FAQs:
Homepage (extern): http://www.ad.siemens.de/teleperm/index_00.shtml
Homepage (intern): http://intra1.nbgm.siemens.de/extern/spiegeln/teleperm/index_00.shtml
10 Appendix
10.1 Files and Search Paths
The following files are copied when theTELEPERM M channel is installed: <LW>:\Siemens\TM_Werkzeuge\Liesmich.txt <LW>:\Siemens\TM_Werkzeuge\Regini.exe <LW>:\Siemens\TM_Werkzeuge\Wincc.ldb <LW>:\Siemens\TM_Werkzeuge\TM_Info.exe <LW>:\Siemens\WinCC\bin\NrmTelpm.nll <LW>:\Siemens\WinCC\bin\TELEPERM M WNF Support.dll <LW>:\Siemens\WinCC\bin\TELEPERM M.chn <LW>:\Siemens\WinCC\bin\Telpmdeu.Ing <LW>:\Siemens\WinCC\bin\Telpmenu.Ing <LW>:\Siemens\WinCC\bin\Telpmfra.Ing <LW>:\Siemens\WinCC\bin\Ydata220.Dat <LW>:\Siemens\WinCC\bin\Ydata230.Dat <LW>:\Siemens\WinCC\bin\TM_RangMeld.exe <LW>:\Siemens\WinCC\BSTMapper\BSTFilter.txt <LW>:\Siemens\WinCC\BSTMapper\Logotm.bmp <LW>:\Siemens\WinCC\BSTMapper\ORPAFilter.txt <LW>:\Siemens\WinCC\BSTMapper\TELEPERM M Import Bausteine.wnf <LW>:\Siemens\WinCC\BSTMapper\TELEPERM M Import ORPA.wnf <LW>:\Siemens\WinCC\BSTMapper\TELEPERM M Meldungen.wnf <LW>:\Siemens\WinCC\BSTMapper\TELEPERM M PseudoAS.wnf <LW>:\Siemens\WinCC\BSTMapper\TELEPERM M Verbindung einrichten.wnf <LW>:\Siemens\WinCC\BSTMapper\TELEPERM M WNF Support.h <LW>:\Siemens\WinCC\BSTMapper\BSTMapper.deu\BSTFilter.txt <LW>:\Siemens\WinCC\BSTMapper\BSTMapper.deu\Logotm.bmp <LW>:\Siemens\WinCC\BSTMapper\BSTMapper.deu\ORPAFilter.txt
<LW>:\Siemens\WinCC\BSTMapper\BSTMapper.deu\TELEPERM M Import Bausteine.wnf <LW>:\Siemens\WinCC\BSTMapper\BSTMapper.deu\TELEPERM M Import ORPA.wnf <LW>:\Siemens\WinCC\BSTMapper\BSTMapper.deu\TELEPERM M Meldungen.wnf <LW>:\Siemens\WinCC\BSTMapper\BSTMapper.deu\TELEPERM M PseudoAS.wnf <LW>:\Siemens\WinCC\BSTMapper\BSTMapper.deu\TELEPERM M Verbindung einrichten.wnf <LW>:\Siemens\WinCC\BSTMapper\BSTMapper.deu\TELEPERM M WNF Support.h <LW>:\Siemens\WinCC\BSTMapper\BSTMapper.deu\BSTFilter.txt <LW>:\Siemens\WinCC\BSTMapper\BSTMapper.enu\Logotm.bmp <LW>:\Siemens\WinCC\BSTMapper\BSTMapper.enu\ORPAFilter.txt <LW>:\Siemens\WinCC\BSTMapper\BSTMapper.enu\TELEPERM M Import Bausteine.wnf <LW>:\Siemens\WinCC\BSTMapper\BSTMapper.enu\TELEPERM M Import ORPA.wnf <LW>:\Siemens\WinCC\BSTMapper\BSTMapper.enu\TELEPERM M Meldungen.wnf <LW>:\Siemens\WinCC\BSTMapper\BSTMapper.enu\TELEPERM M PseudoAS.wnf <LW>:\Siemens\WinCC\BSTMapper\BSTMapper.enu\TELEPERM M Verbindung einrichten.wnf <LW>:\Siemens\WinCC\BSTMapper\BSTMapper.enu\TELEPERM M WNF Support.h <LW>:\Siemens\WinCC\BSTMapper\BSTMapper.fra\BSTFilter.txt <LW>:\Siemens\WinCC\BSTMapper\BSTMapper.fra\Logotm.bmp <LW>:\Siemens\WinCC\BSTMapper\BSTMapper.fra\ORPAFilter.txt <LW>:\Siemens\WinCC\BSTMapper\BSTMapper.fra\TELEPERM M Import Bausteine.wnf <LW>:\Siemens\WinCC\BSTMapper\BSTMapper.fra\TELEPERM M Import ORPA.wnf <LW>:\Siemens\WinCC\BSTMapper\BSTMapper.fra\TELEPERM M Meldungen.wnf <LW>:\Siemens\WinCC\BSTMapper\BSTMapper.fra\TELEPERM M PseudoAS.wnf <LW>:\Siemens\WinCC\BSTMapper\BSTMapper.fra\TELEPERM M Verbindung einrichten.wnf
<LW>:\Siemens\WinCC\BSTMapper\BSTMapper.fra\TELEPERM M WNF Support.h
The following files are copied when the
<LW>:\Siemens\TM_ocx\TM_B.ocx <LW>:\Siemens\TM_ocx\Tm_C.ocx <LW>:\Siemens\TM_ocx\TM_DZ.ocx <LW>:\Siemens\TM_ocx\TM_EG.ocx <LW>:\Siemens\TM_ocx\TM_EK.ocx <LW>:\Siemens\TM_ocx\TM_EU.ocx <LW>:\Siemens\TM_ocx\TM_F.ocx <LW>:\Siemens\TM_ocx\TM_FN.ocx <LW>:\Siemens\TM_ocx\TM_M.ocx <LW>:\Siemens\TM_ocx\TM_MSB.ocx <LW>:\Siemens\TM_ocx\TM_R.ocx <LW>:\Siemens\TM_ocx\TM_RE.ocx <LW>:\Siemens\TM_ocx\TM_RI.ocx <LW>:\Siemens\TM_ocx\TM_RK.ocx <LW>:\Siemens\TM_ocx\TM_RN.ocx <LW>:\Siemens\TM_ocx\TM_S.ocx <LW>:\Siemens\TM_ocx\TM_TVB.ocx <LW>:\Siemens\TM_ocx\TM_V.ocx <LW>:\Siemens\TM_ocx\TM_MKS.ocx <LW>:\Siemens\TM_ocx\TM_Sym.ocx <LW>:\Siemens\TM_ocx\Zusanz.ocx <LW>:\Siemens\TM_ocx\TM_GLobal.dll <LW>:\Siemens\TM_ocx\Language.dll <LW>:\Siemens\TM_ocx\OCX_Texte407.dll <LW>:\Siemens\TM_ocx\OCX_Texte409.dll <LW>:\Siemens\TM_ocx\OCX_Texte40A.dll <LW>:\Siemens\TM_ocx\OCX_Texte40C.dll <LW>:\Siemens\TM_ocx\OCX_Texte40E.dll <LW>:\Siemens\TM_ocx\OCX_Texte413.dll <LW>:\Siemens\TM_ocx\OCX_Texte41D.dll <LW>:\Siemens\TM_ocx\TMOCX.dll <LW>:\Siemens\TM_ocx\TMCOND.dll <LW>:\Windowsdir\TMOCX.ini
The following files are copied when the
<LW>:\Siemens\TM7_ocx\TM7_A.ocx <LW>:\Siemens\TM7_ocx\TM7_A_MotVen.ocx <LW>:\Siemens\TM7_ocx\TM7_B.ocx <LW>:\Siemens\TM7_ocx\TM7_C.ocx <LW>:\Siemens\TM7_ocx\TM7_F.ocx <LW>:\Siemens\TM7_ocx\TM7_FN.ocx <LW>:\Siemens\TM7_ocx\TM7_M.ocx <LW>:\Siemens\TM7_ocx\TM7_R.ocx <LW>:\Siemens\TM7_ocx\TM7_RN.ocx <LW>:\Siemens\TM7_ocx\TM7_V.ocx <LW>:\Siemens\TM7_ocx\PCX_Texte407.dll <LW>:\Siemens\TM7_ocx\PCX_Texte409.dll <LW>:\Siemens\TM7_ocx\PLanguage.dll <LW>:\Windowsdir\TMOCX.ini