SERVICE MANUAL
No. 00ZFO3MKCUSME
FACSIMILE
OPTION MEMORY
UPGRADE PWB
MODEL
This machine is an option memory unit applica- ble to the machines
CONTENTS
[1] General description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
[2] Installation procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 [3] Diagnostic mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
[4] Circuit schematics and parts layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
[5] Parts guide
Parts marked with "" is important for maintaining the safety of the set. Be sure to replace these parts with specified ones for maintaining the safety and performance of the set.
This document has been published to be used
SHARP CORPORATION for after sales service only.
The contents are subject to change without notice.
1 - 1
[1] General description
This machine is an option memory unit applicable to the machines
[2]Installation procedure
(pay attention to static electricity)
To install the option memory unit, check the following in advance.
1)Make sure that the remaining memory capacity is 0%.
If the remaining memory capacity is not 0%, this implies that any data remains in the image memory on the control PWB.
2)Check that a sufficient quantity of paper exists. If there is no paper or paper is lacking, replenish the machine with paper, and print the data received and stored in the memory.
3)Then, check whether there is any confidentially received information, seeing the confidential reception data list ("FUNK" + "2" + "1" + "0"). If any confidentially received information is found, input the ID No. of specific reception box, and print the confidentially received informa- tion.
4)After that, check whether there is timer sending information, seeing the timer sending information list ("FUNK" + "2" + "0" + "2"). It is re- quired to teach users that any timer sending information, if exists, is cleared after the option memory unit is installed and, accordingly, users have to set again the timer sending and do the timer sending.
Install the option memory unit in the following procedure.
1)Remove the ROM cover of facsimile.
2)Insert two spacers to control PWB, and then connect it to the connec- tor CNOP of control PWB.
(Fig. 1)
3)Mount the control PWB to which the option memory has been con- nected in the machine.
(Tighten the screws, and connect the connector without fail.)
4)Mount the ROM cover.
5)After installation turn on the power switch.
P L E A S E W A I T A M O M E N T
appears.
Then, after several seconds,
[3] Diagnostic mode
Successively input "FUNK" + "9" + "" + "8" + "#" + "7". Then,
appears.
After that, press the "START" key.
Then,
0 1 : S O F T S W I T C H M O D E
P R E S S S T A R T K E Y
appears.
Select MEMORY CLEAR, using the
1 1 : M E M O R Y C L E A R
P R E S S S T A R T K E Y
After completion of MEMORY CLEAR, the following indication appears.
1 2 : F L A S H M E M O R Y
P R E S S S T A R T K E Y
Select ROM/RAM test, using the
0 3 : R O M & R A M C H E C K
P R E S S S T A R T K E Y
(This model is provided not only with flash memory for image but also SRAM to enhance the function to store the number of transmissions and receptions.)
When the "START" key is pressed again, the memory of machine
(control PWB) and memory of memory unit (excepting the flash mem- ory) are checked.
An example of indication
After that, the indication shown below appears, and the result table (Fig. 2) is printed.
After completion of ROM/RAM test the following indication appears.
Then, select the flash memory test, using the
1 2 : F L A S H M E M O R Y
P R E S S S T A R T K E Y
In the diagnostic mode perform the image memory (standard, option) write/read test, as well as complete erase test.
When the "START" key is pressed,
S ??? ??? E
T E S T E X E C U T I N G
appears, and the indication changes from
After completion of writing of data in all flash memories, the following indication appears.
S E
T E S T E X E C U T I N G
After that the
??? 1 ???
Then, the result table (Fig. 3) is printed.
In case of mismatch, the buzzer emits 9 short tones .
After that, the result table (Fig. 4) is output.
1)If any error occurred, check connection of connector CNOP (check for bending and breakage of pin of connector), check that the option memory unit has been mounted as specified, and then turn on again the power supply, and check.
2)If the same error occurs persistently after the measures stated in item
1 above were taken, replace the option memory unit, and check.
3)If the same error occurs again after the measures stated in item 2) were taken, check the control PWB.
CONTROL PWB
OPTION MEMORY
PWB UNIT
Fig. 1
ROM/RAM CHECK LIST
Fig. 2
FLASH MEMORY CHECK REPORT
S I Z E = 5MB (With Option Flash memory)
FLASH MEMORY = OK (15S, 24S, 27S)
BANK CHANGEOVER = OK
B A N K = OK
Fig. 3
FLASH MEMORY CHECK REPORT
S I Z E = 5MB (With Option Flash memory)
FLASH MEMORY = NG (15S, 24S, 27S)
BANK CHANGEOVER = NG
B A N K = NG
Fig. 4
??? 2 ???
6
6
(*1) :
??? 3 ???
5
4
3
DG DG
5
4
3
GND 0
Vcc 0
DG
GND 0
Vcc 0
DG
2
1
/FLS0
/FLS7
C107 0.1
DG
2
1
ABCDEFGHI
ABCDEFGHI
??? 4 ???
6
5
4
3
2
1
2/3
D[15:0]
6
3
2
1
N.M.
ABCDEFGHI
3MK
ABCDEFGHI
5
4
??? 5 ???
3
2
1
DG
4
3
2
1
ABCDEFGHI
Option memory PWB parts layout (Top side)
Option memory PWB parts layout (Bottom side)
??? 6 ???
[5] Parts guide
COPYRIGHT ?? 1999 BY SHARP CORPORATION
ALL RIGHTS RESERVED.
No part of this publication may be reproduced, stored in a retrieval system, or transmitted in
any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without prior written permission of the publisher.
SHARP CORPORATION
Communication Systems Group
Quality & Reliability Control Center
Higashihiroshima, Hiroshima
Printed in Japan