Please read before operating your new Air Purifier
Some odour ingredients absorbed by the filter may become separated and may be discharged through the air outlet and result in additional odour. De- pending on the usage environment, especially when the product is used in a condition significantly more severe than household use, this odour may become strong in a shorter period than expected.
In this case we recommend purchasing the optional replacement filter.
NOTE
???The air purifier is designed to remove
???It is suggested to open the window a bit when you are smoking in order to facilitate ventilation.
Dust Collection / Deodorising Filter
Elements removed by filter
Dust
pollen, dust, particles of cigarette smoke, pet dander
Odour
cigarette smoke odour, household odour (toilet / raw garbage / pet, etc.)
ENGLISH
FEATURES
"Plasmacluster" technology
Plasmacluster technology uses plas- ma discharge to produce and release the same positive and negative ions as those found in nature ("Plasma- cluster ions").
This is a unique air cleaning technolo- gy of the SHARP CORPORATION for breaking down and inactivating such potential allergens as the fecal matter or corpses of aerial mites*1, viruses *2 and mould and bacteria *3 suspended in the air, and has been substantiated by
When there is a high density of Plas- macluster ions in the air, the smell of cigarette smoke trapped in curtains or sofas is removed in about 80 min- utes*4, and when clothing is hung in a place exposed to the direct air ex- pelled from the unit generating Plas- macluster ions, the smell of sweat is reduced to a virtually imperceptible level in one night (about 6 hours).
*1 Graduate School of Advanced Sci-
ences of Matter, Hiroshima University,
Japan
Measurement of action on the poten- tial allergens of aerial mites in (13m??)
*2 Retroscreen Virology, Ltd., London, UK Measurement of ratio of viruses elimi- nated from the air in a 1m?? box
*3 Ishikawa Health Service Association, Japan
Measurement of aerial mold and bac- teria with an air sampler (13m??)
*4 Japan Spinners Inspecting Foundation, Japan
Evaluation of deodorizing effect on
CONTENTS
IMPORTANT SAFETY
TROUBLESHOOTING ..............................
Thank you for purchasing the SHARP Air Puri- fier. Please read this manual carefully for the correct usage information. Before using this product, be sure to read the section: ???Important Safety Instructions.???
After reading this manual, retain it in a conven- ient location for future reference.
IMPORTANT SAFETY INSTRUCTIONS
When using electrical appliances, basic safety precautions should be followed, including the following:
WARNING - To reduce the risk of electrical shock, fire or injury to persons:
???Read all instructions before using the unit.
???Use only a
???Do not use the unit if the power cord or plug is damaged or the connection to the wall outlet is loosened.
???Periodically remove dust from the power plug.
???Do not insert fingers or foreign objects into the intake or air outlet.
???When removing the power plug, always hold the plug and never pull the cord.
Electrical shock and/or fire from short circuit may occur as a result.
???Do not remove the plug when your hands are wet.
???Do not use this unit near gas appliances or fireplaces.
???Remove the power plug from the wall outlet before cleaning the unit and when not using the unit.
Electrical shock from bad insulation and/or fire from short circuit may occur as a result.
???If the power cord is damaged, it must be replaced by the manufacturer, its service agent,
Sharp Approved Service Centre or similarly qualified person in order to avoid a hazard.
???Do not operate when using aerosol insecticides or in rooms where there is oily residue, incense, sparks from lit cigarettes, chemical fumes in the air or in very high humidity conditions, such as a bathroom.
???Be cautious when cleaning the unit. Corrosive cleansers may damage the exterior.
???Only Sharp Approved Service Centre should service this air purifier. Contact the nearest Service Centre for any problems, adjustments, or repairs.
???This appliance is not intended for use by persons (including children) with reduced physical, sen- sory or mental capabilities, or lack of experience and knowledge, unless they have been given su- pervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure they do not play with the appliance.
NOTE - Radio or TV Interference
If this air purifier should cause interference to radio or television reception, try to correct the interfer- ence by one or more of the following measures:
???Reorient or relocate the receiving antenna.
???Increase the separation between the unit and radio/TV receiver.
???Connect the equipment into an outlet on a circuit different from that to which the receiver is con- nected.
???Consult the dealer or an experienced radio/TV technician for help.
CAUTIONS CONCERNING OPERATION
???Do not block the intake and/or air outlet.
???Do not use the unit near or on hot objects, such as stoves or heaters or where it may come into contact with steam.
???Do not lay the unit down when using.
???Always hold the handle on both sides of the unit when moving it.
Holding the back panel when carrying may cause it to detach, thus dropping the unit and resulting in bodily injury.
???Do not operate the unit without the filter.
???Do not wash and reuse the filter .
Not only does it not improve filter performance, but also may cause electrical shock or malfunction.
???Clean the exterior with a soft cloth only.
The unit surface may be damaged or cracked.
In addition, the sensors may malfunction as a result.
INSTALLATION GUIDELINES
???During the operation of the product, please place the unit at least 2 m away from equipment utilizing electrical waves such as televisions, radios or wave clocks.
???Avoid locations where curtains, etc., come into contact with the intake or air outlet.
Curtains, etc., may become dirty or a malfunction may occur.
???Avoid locations where the unit is exposed to condensation, due to rapid temperature changes.
(If it is unavoidable please allow unit to stand for 1 hour before switching on.) (Use under appropriate conditions between 0 and 35??C in the room.)
???Place on a stable surface with sufficient air circulation.
When placing the unit on a heavily carpeted area, it may cause the unit to vibrate slightly.
???Do not install when there is a possibility of soot, such as in a kitchen, etc.
The unit surface may crack as a result.
???Leave about 60cm of space from the wall.
The wall behind the air outlet may become dirty as time passes. When using the unit for extended period of time in the same location, use a vinyl sheet, etc., to prevent the wall from becoming dirty. In addition, periodically clean the wall.
INDONESIA ENGLISH
FILTER GUIDELINES
???Follow the instructions in this manual for correct care and maintenance of the filter. Use only filter designed for this product.
PART NAMES
MAIN UNIT DISPLAY
POWER ON/OFF Button
Plasmacluster Ion ON/OFF Button
MODE Button
Odour
Sensor
Fan Speed
Indicator Lights
CLEAN SIGN
The odour sensor continuosly monitors the air and changes colour depending on air punity.
Plasmacluster
Ion ON/OFF
Indicator Light
Green Orange Red
ILLUSTRATIVE DIAGRAM
Handle
Main Unit
INCLUDED
??? Operation manual
BACK
Handle
Tab
Filter
(Dust Collection / Deodorising Filter)
Date Label
Air Outlet
Back Panel
Air Inlet
Power Cord
Plug
(Shape of plug depends on country.)
INDONESIA ENGLISH
PREPARATION Be sure to remove the power plug from the wall outlet.
FILTER INSTALLATION
To maintain the quality of the filter, they are installed in the main unit and packed in plastic bag. Be sure to remove the filter from the plastic bag before using the unit.
Tab
1 Remove the filter
1 Remove the Back Panel.
Pull the tab at the top of the Back Panel.
2 Remove the Filter from the plastic bag.
2 Intall the filter
1 Place the Filter within the main unit.
Do not install the filter backwards or the unit will not operate properly.
INDONESIA ENGLISH
Date Label
OPERATION
MAIN UNIT OPERATION
MODE Button
Plasmacluster Ion
ON/OFF Button
Power ON/OFF Button
???Press to start operation (short beep) and stop operation (long beep)
???Plasmacluster Indicator Light and Fan Speed Indicator Light turn on/off.
???Unless the power cord has been unplugged, the opera- tions starts in the previous mode it was operated in.
MODE Button
???Press the MODE Button to select the desired fan speed. Indicator Lights will show the fan speed currently select- ed.
???The operation mode can be switched as below.
AUTO operation
The fan speed is automatically switched
(between HIGH and LOW) depending on the amount of impurities in the air. The sensors detect impurities for efficient air purfication.
LOW operation
The unit will operate quietly using minimal air intake.
MAX operation
The unit will operate at a fan speed of MAX.
MEDIUM operation
The unit will operate at a fan speed of MEDIUM.
Plasmacluster Ion ON/OFF Button
Press the Plasmacluster Ion ON/OFF Button to turn Plasmacluster Ion Mode ON and OFF.
When Plasmacluster Ion is ON, the Plasmacluster Ion
Indicator Light will turn on.(blue)
<When the
Press the Plasmacluster Ion ON/OFF Button for 3 sec- onds to switch the
CARE AND MAINTENANCE
To maintain optimum performance of this air purifier, please clean the unit including the filter periodically.
When cleaning the unit, be sure to unplug the power cord, and never handle the plug with wet hands. Electrical shock and/or bodily injury may occur as a result.
BACK PANEL and SENSORS
Gently remove dust from the sensor opening and the back panel, using a vacuum cleaner attachment or similar tool.
INDONESIA ENGLISH
UNIT
Care Cycle Whenever dust accumulates on the unit or every 1 month
To prevent dirt or stains on the main unit, clean as often as necessary. If stains are allowed to remain, they may become difficult to remove.
Wipe with a dry, soft cloth
For stubborn stains or dirt, use a soft cloth dampened with warm water.
Do not use volatile fluids
Benzine, paint thinner, polishing powder, etc., may damage the surface.
Do not use detergents
Detergent ingredients may damage the unit.
CARE AND MAINTENANCE
FILTER REPLACEMENT GUIDELINES
Filter life vary depending on the room environment, usage, and location of the unit.
If dust or odour persists, replace the filter.
(Refer to ???Please read before operating your new Air Purifier???)
Guide for filter replacement timing
???The following filter life and replacement period is based on the condition of smoking 5 cigarettes per day and the dust collection/deodorization power is reduced by half compared with that of new filter.
We recommend to replace the filter more frequently if the product is used in a condition sig- nificantly severer than normal household use.
Dust Collection /
Deodorizing Filter
Please consult your dealer for purchase of replacement filter.
Disposal of Filter
Please dispose of the replaced filter according to the local disposal laws and regulations.
Filter materials :
???Filter : Polypropylene
???Frame : Polyester
???Deodorizer : Activated charcoal
TROUBLESHOOTING
Before calling for service, please review the Troubleshooting chart below, since the problem may not be a unit malfunction.
INDONESIA ENGLISH
SPECIFICATIONS
*1 Size of a room which is appropriate for operating the unit at maximum fan speed.
???It indicates the space where a certain amount of dust particles can be removed in 30 minutes(JEM1467).
*2 Size of a room in which approximately 7000 ions can be measured per cubic centimeter in the center of the room (at a height of approximately 1.2 meters from the floor) when the product is placed next to a wall and run at the MAX operation position.
Standby Power In order to operate the electrical circuits while the power plug is inserted in the wall outlet, this product consumes about 1.0W of standby power.
For energy saving, unplug the power cord when the unit is not in use.
The class of the HEPA filter by EN 1822 is H10.