FEATURES
Cluster Ion Control
The unit controls the ratio of minus cluster ions and plus cluster ions depending on the condition of the room.
??? Clean mode
Approximately the same amount of plus and minus cluster ions are discharged. This mode is effective for reducing floating mold and household odors in the air.
??? Refresh mode
It is said that plenty of minus ions exist in places such as waterfalls or forests.
In this operation mode, minus ions will be released in an increased rate, in order to bring the room air close to this condition.
??? AUTO cluster ion mode
The unit will switch between the Clean mode and Refresh mode automatically depending on the amount of pollution in the air detected by dust and odor sensor.
HEPA Filter
???
Powerful deodorization by large particles of columnar charcoal.
FOR UNDERSTANDING
THE PRODUCT
Some of the odor ingredients adsorbed by the filters become sepa- rated and are discharged through the exhaust port as odor.
Depending on the usage environment, this odour may become strong after several months and the exhaust port may smell.
In this case, purchase an exchange filter
This equipment complies with the requirements of Directives 89/ 336/EEC and 73/23/EEC as amended by 93/68/EEC.
CONTENTS
Thank you for purchasing the SHARP
After reading this manual, retain it in a conven- ient location for future reference.
This product is for household use only.
SAFETY PRECAUTIONS
???Do not use the unit if the power cord or plug is damaged or the connection to the wall outlet is loose.
Electrical shock, short circuit and/or fire may occur as a result.
???Do not damage, break, coat, forcefully bend, pull, twist, bundle, pinch or place heavy objects on the power cord.
If the power cord is damaged, fire and/or electrical shock may occur as a result.
???Use AC 220~240V only.
???Do not modify. Repair and disassembly of this product are to be performed by authorized service personnel only.
Fire, electrical shock and/or bodily injury may occur if not.
For repair, contact your dealer or the nearest Sharp Service Center.
???Periodically remove dust from the power plug
Accumulated dust on the power plug may cause bad insulation from humidity, etc. Fire and/or electrical shock may occur as a result.
???When cleaning the unit, be sure to remove the power plug from the wall outlet.
In addition, never handle the power plug with wet hands. Electrical shock and/or bodily injury may occur as a result.
???Do not use the unit where there are oil ingredients such as cooking oil, etc., in the air.
Cracking of the unit surface may occur as a result.
???Do not wipe the unit with benzene or paint thinner. Also, do not spray insecticides on the unit.
Cracking, electrical shock and/or fire may occur as a result.
???Do not operate the unit when using indoor
Chemical ingredients may accumulate within the unit and then discharge from the exhaust port when the unit operates. Discharge of such chemicals may be unhealthy to your body.
???Do not allow the unit to intake flammable gases, sparks from lit cigarettes, incense, etc.
The unit may ignite as a result.
???Do not use the unit where it is humid, such as in a bathroom, etc., or where the unit may get wet.
Electrical shock and/or malfunction may occur as a result.
???Do not insert fingers or foreign objects into the intake or exhaust ports.
Electrical shock and/or malfunction may occur as a result.
???When mounting to a wall, select a sturdy wall or studding.
The unit may fall if not.
???When removing the power plug, always hold the plug and never pull the cord.
Electrical shock and/or fire from short circuit may occur as a result.
???Ventilate when using the unit along with a heating appliance.
Carbon monoxide poisoning may occur as a result.
???Remove the power plug when not using the unit.
???If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or similarly qualified person in order to avoid a hazard.
???The batteries must be disposed of safely.
CAUTIONS CONCERNING THE USAGE OF THIS PRODUCT
???Do not block the intake and exhaust ports.
???Do not use the unit near or on hot objects, such as a stove, etc. Also, do not use the unit where it may come into contact with steam.
???Do not use the unit on its side.
Deformation, malfunction and/or overheating of the motor may occur as a result.
???Do not install when there is generation of lampblack, such as in a kitchen, etc.
???Do not use detergent when cleaning the unit.
The unit surface may become damaged or cracked. In addition, the sensors may malfunction as a result.
???When transporting the unit, always hold the handle on the back of the unit.
Holding the front panel when carrying may cause it to detach, thus dropping the unit and resulting in bodily injury.
CAUTIONS WHEN MOUNTING THIS PRODUCT ON A WALL
???Never mount the unit to a thin wall or plasterboard of insufficient strength.The unit may fall as a result.
???When mounting the unit to a wall, remove the front panel and hold the main unit.
Holding the front panel may cause it to become detached, thus dropping the unit and resulting in bodily injury.
???Do not install when there is generation of lampblack, such as in a kitchen, etc.
The unit surface may crack or the sensors may malfunction as a result.
CAUTIONS CONCERNING THE INSTALLATION
DO NOT USE THE REMOTE CONTROL IN THE FOLLOWING LOCATIONS
???Locations where there are inverter lighting equipment or electronic spontaneous lighting equip- ment
The remote control may become inoperative. In this case, move away from such lighting equipment or change direction.
???Location exposed to direct sunlight
The unit may not received signals from the remote control
INSTALLATION
???Leave at least 2m of space from televisions and radios
Electrical interference may occur if not.
???Leave at least 60cm of space from the wall
The motor may overheat, causing malfunction if not.
???Avoid a location where sensors are exposed to direct wind
The unit may not operate properly.
???Avoid a location where curtains, etc., come into contact with the intake or exhaust port.
Curtains, etc., may become dirty or malfunction may occur as a result.
EFFECTIVE USAGE
???Place on a stable surface with sufficient air circulation
???Near smoking area
Air pollution is detected quickly.
ABOUT THE FILTER
???Do not wash or reuse Apatite HEPA filter and deodorization filter.
???Small dust particles and odors such as tobacco smoke rise and accumulate at the top of the room.
???Large dust such as pollen and house dust accumulate at the bottom of the room.
???The wall, etc., behind the exhaust port may become dirty as time passes. When using the unit for extensive period in the same location, use a vinyl sheet, etc., to prevent the wall from becoming dirty. In addition, periodically clean the wall, etc.
NAMES OF PARTS
Plasmacluster
??? To reset the base pollution rate of the
MODE-ON/OFF button
(Used to select operations or turn the unit off)
Main unit
HEPA filter (white)
(Dust collection filter)
(W/ apatite antibacterial filter)
(Deodorization filter)
Front panel
Remote control
Hook
Stand
(Be sure to mount for tabletop instal- lation)
Thumbscrew
CLUSTER ION LAMP
Cluster ion operation is selected using the remote control.
Blue light
When the cluster ion operation is in the Clean mode or AUTO cluster ion mode and the air in the room is dirty, the light turns on and the unit will operate in the Clean mode.
Green light
When the cluster ion operation is in the Refresh mode or AUTO cluster ion mode and the air in the room is clean, the light turns on and the unit will operate in the Refresh mode.
Light off
No cluster ions are generated.
If the lamp is to bright when sleeping, or if the ion generation noise is irritating, turn off the cluster ion operation.
BACK
Handle
Exhaust port
Power cord
Power plug
ACCESSORIES
Remote control
(1 unit)
Battery
(AA battery X 2 units)
When used on a tabletop
Stand
(1 unit)
Thumbscrew
(2 units) Located on bottom of stand
When wall mounting this product
Wall mounting bracket 1
Wall mounting bracket 2
Wood screw
(4 units)
Small screw
(2 units)
Cushions
(2 units)
INSTALLATION
WHEN USING THE UNIT ON A
TABLETOP
FIXING THE STAND
1
2 Place the unit with its front side facing down on a flat and stable surface.
???Place a soft cloth, etc., to prevent damaging the unit.
3 Insert the tabs on the stand into the holes on the main unit and fix the stand using the supplied thumbscrews (2 units).
Tabs Holes
WHEN WALL MOUNTING
CAUTION
???When mounting the air purifier on a wall, the wall will become dirty as time passes. To pre- vent this, place a vinyl sheet, etc., around the unit.
???Ensure that the wall is suitable for mounting the air purifier.
???Do not install in a location with heavy smoke, such as in a kitchen, etc.The unit surface may crack as a result.
1Determine the mounting location
Leave space around the bracket by referring to the illustration below. The unit cannot be mounted if there is insufficient spacing around the bracket.
75cm or more
69cm or more from the ceiling
Size of main
unit
CAUTION
Mount on a flat sur- face
???Do not mount the unit to a thin wall with little strength such as a plas- terboard, etc. The unit may fall and can be very dangerous.
Thumb- screws
2 Mount mounting bracket 2 to the main unit
Mount the bracket to the back of the main unit using the small screws included.
Mounting bracket 2
Small screws (2 units)
3 Place the cushions as shown
Cushions (2 units)
4 Mount the main unit
(1)Align the horizontal positions of mounting brackets 1 and 2 and hook the bracket 2 to bracket 1.
(2)Hold the bottom
of the main unit, pull the unit to- wards you and then pull down.
5 Check the installation
??? Check to make sure that the tabs on mount- ing bracket 2 are securely mounted to the tabs on mounting bracket 1.
??? Check that the power cord is not pinched.
REMOVING THE UNIT
Pull the bottom of the unit towards you and then lift.
NOTES
???When removing the unit disconnect the power cord.
PREPARATION
Be sure to remove the power plug from the wall outlet.
INSTALLING THE FILTERS
To maintain the quality of the filters, they are installed in the main unit within polyvinyl bags. Be sure to remove the filters from the polyvinyl bags before using the unit.
1 Remove the filters
1 Place the unit facing up
Place the unit on a table, etc., so that the stand does not touch the surface.
2 Remove the front panel
Press in the hook on the bottom of the front panel and lift to remove.
2
1 Hook
Place so stand does not touch the surface
Soft cloth
1
Prefilter
3 Remove the
INSERTING BATTERIES IN THE REMOTE CONTROL
1 Remove the
back cover
Press and slide the back cover to re- move.
2 Insert batteries
Insert batteries with and as shown below.
3 Closecover the back
About the batteries
???The battery life is about 1 year.
Replace the batteries when the remote con- trol becomes inoperative.
???Incorrect usage of the batteries may cause battery fluid leakage and/or damage. Take caution of the following when handling:
???When replacing the batteries, replace both batteries with new ones of the same type. (Use AA alkaline batteries (2 units) or AA manganese batteries (2 units).)
???When not using the unit or remote con- trol for an extensive period, remove the batteries.This prevents malfunction of the remote control from battery fluid leakage.
3 Insert the 4 tabs on the
main unit.
Back of front panel
4 Fill in the usage start date on Replacement label the replacement label affixed on
the back of the front panel and then mount the front panel.
???Operate the remote control facing the main unit (re- ceiver).
???The signal range is about 7m (front).
???Make sure there are no objects blocking the path of the signal.
???A Beep will be heard from the main unit when a signal is received.
NOTE
???Avoid strong impact on the remote control. In addition, do not wet the remote control or place it under direct sunlight or near a stove, etc. Malfunction may occur.
Receiver
Transmitter
Plasmacluster
Cluster ion lamp
The unit will start operation when the
(The unit will start operation in AUTO mode)
???During operation, the cluster ion lamp will light.
(During start of operation, the cluster ion mode will be AUTO)
The operation mode suitable for the usage condition can be set.
Stop
AUTO operation
The fan level is automatically switched (High, Median, Silent) depend- ing on the amount of pollution in the air detected by the dust sensor for efficient air purification.
Silent operation
The unit will operate using little air.
Median ~ Max operation
The unit will operate with fan level of median, high or max.
*Tobacco smoke mode operation
The unit will operate in High for 10 minutes, then the unit will return to the AUTO mode.
10 minutes: High fan level
AUTO mode operation
Pollen mode operation
*It can not remove the noxious substances (carbon monoxide etc.) from cigarette smoke.
The unit will operate in High for 10 minutes, then the unit will alternately operate between Median and High.
10 minutes: High fan level
20 minutes: Median level
20 minutes: High fan level
Manual (fan level) button
The fan level can be switched between Silent, Median, High and Max.
Silent operation but- ton
Operation will be in the Silent mode with little air.
AUTO (fan level) but- ton
The fan speed depends upon the amount of pollution in the air.
Max operation button
Used to quickly clean the air in the room.
Pollen mode opera-
*Tobacco smoke mode operation but- ton
Unit will operate effectively when smoking cigarettes, etc.
ON/OFF button
Used to start AUTO operation (short beep) and stop opera- tion (long beep).
RESET
Plasmacluster
AUTO OFF
tion button
The unit operates effectively when you suspect pollen in the air.
OFF timer button
Used to set the OFF timer. The set time switches every time the button is pressed as shown below.
1 hour
4 hours
Filter reset button
Press this button after replac- ing the filters.
AIR PURIFIER
8 hours Cancel
*It can not remove the noxious substances (carbon monoxide etc.) from cigarette smoke.
At the start of operation, the Cluster ion mode is also set to AUTO.
Cluster ion select button
AUTO cluster ion button
The unit will switch between the Clean mode and Refresh mode automatically depending on the amount of pollution in the air detected by the dust and odour sensor.
Clean button
The unit will constantly operate in the Clean mode. The Clean mode is effective for removing mold fungus in the air.
(Cluster ion lamp on (blue))
OFF button
The generation of ions is stopped and the cluster ion lamp is turned off.
Refresh button
The unit will constantly operate in the Re- fresh mode. The Refresh mode maintains the balance of ions in the air for a refresh- ing effect.
(Cluster ion lamp on (green))
If the room smells especially moldy, operate the unit in the Clean mode.
CARE AND MAINTENANCE
(To maintain the best performance of this product, please clean the unit periodically.)
When cleaning, be sure to remove the power plug from the wall outlet. In addition, never handle the power plug with wet hands.
Electrical shock and/or bodily injury may occur as a result.
For soiling on the main unit and the installed surface, clean as early as possible. Stubborn dirt may be hard to remove.
Dry wipe with a soft cloth
For stubborn dirt, wipe with a soft cloth damp- ened with water or warm water of 40??C or less.
Do not use volatile fluids
Benzene, paint thinner, polishing powder, etc., may damage the unit surface.
Do not use detergents
Detergent ingredients may damage the unit surface.
Do not get wet
Never apply water on the unit.
ODOR SENSOR
DUST SENSOR
The sensitivity of the sensors will become unstable if the odor or dust sensor is dirty or blocked.
Remove dust on the surfaces of the sensor openings using a vacuum cleaner.
Clean using the nozzle of a vacuum cleaner without removing the
NOTE
Never wash or clean the HEPA filter or
GUIDE FOR LIFE OF FILTERS
???The replacement period differs depending on the usage hours and location of installation.
???Some of the odor ingredients adsorbed by the filters become separated and are discharged through the exhaust port as odor.
Depending on the usage environment, this odor may become strong in several months and the exhaust port may smell.
If dust or odors cannot be removed easily, replace the filters.
(Refer to page1, FOR UNDERSTANDING THE PRODUCT)
Guide for filter replacing timing
???The following is a guide from JEM 1467 by Japan Electrical Manufacturers Association in Japan, and in JEM 1467, the replacement period is set as when smoking 10 cigarettes per day and the dust collection/deodorization power is reduced by half that of new filters.
???The filter timer lamp is programmed to light in about 5 years, when using the unit for 12 hours everyday, in order to indicate accumulated usage time of the guide above.
???The filter timer lamp is to be used only as a guide.
???The operation hours are kept in memory even when removing the power plug for transportation to another room, etc.
REPLACING THE FILTERS
1
2
See page 8 ???Installing the filters??? for the replacement method.
After replacing the filters:
Be sure to press the Reset button on the remote control with the power plug inserted in the wall outlet.
A short beep will be heard and the operation hours stored in the memory will be reset. If the filter replacement lamp is on, the lamp will turn off.
3 Fill in the usage start date of the filters on the date label in- cluded with the replacement filters. Affix the label on top of the replacement label that is already on the back of the front panel.
Replacement filters
???HEPA filter: 1 unit
???
Please ask for replacement filters at your dealer of purchase.
Cautions concerning the disposal of filters
Please dispose of replaced filters according to the local disposal laws and regulations. HEPA filter materials:
???Filter: Polypropylene
???Frame: Polyester
???Deodorizer: Activated charcoal
???Frame: Polyester
TROUBLESHOOTING
Before calling for repair, check the symptoms below for possible remedies, since the problem may not be a malfunction of the unit.
About the reduction of standby power
In order to operate the electrical circuits while the power plug is inserted in the wall outlet, this product consumes about 0.8W of standby power.
(At this time, the power lamp will be on) For the conservation of energy, remove the power plug when not using the unit
SHARP CORPORATION