MasterColor?? Ceramic Metal Halide
70 Watt PAR38 Spot 4K Lamp
Featuring FadeBlock??? & ALTO?? Lamp Technology
5 7/16"
MasterColor?? Spectral Power
50
0
CDM70/PAR38/SP/4K
Degrees from Beam Axis
700
15
??? Ordering Information
??? Physical Characteristics
??? Operating Characteristics (Photometric)
??? Operating Position
Note: Electronic ballasts are preferred for optimum performance,
energy efficiency and circuit loading.
MasterColor?? Ceramic Metal Halide 70 Watt PAR38 Spot 4K Lamp featuring FadeBlock??? & ALTO?? Lamp Technology
Electrical Data (Subject to change without notice)
Lamp Watts (Nominal) . . . . . . . . . . . . . . . . . . . . . . . . . 70
Lamp Operating Voltage (rms) (Nominal) (2) . . . . . . . . . 85
Initial Lamp Voltage Range (rms) (3) . . . . . . . . . . . . . . . .
Lamp Operating Current (Amps) (rms) (Nominal). . . . 0.9
Lamp Current Crest Factor (Maximum). . . . . . . . . . . . 1.8
Ballast Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ANSI M143/M98
Ballast Open Circuit Voltage (Minimum) . . . . . . . . . . . . 198
Pulse Peak Volts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3000 Min., 4000 Max.
Pulse Width @ 90% Peak. . . . . . . . . . . . . . . . . . . . . . . 2 Micro Second Min.
Pulse Repetition Rate (Minimum) . . . . . . . . . . . . . . . . . 2 per Half Cycle
Minimum Operating Temperature. . . . . . . . . . . . . . . . .
(1)Measured at 100 hours of life in vertical position.
(2)Measured at rated lamp watts on a linear reactor. LPW does not include ballast losses.
(3)Measured with the lamp operating at rated watts.
WARNINGS, CAUTIONS AND OPERATING INSTRUCTIONS
R???WARNING: These lamps can cause serious skin burn and eye inflammation from short wave ultraviolet radiation if outer envelope
of the lamp is broken or punctured. Do not use where people will remain for more than a few minutes unless adequate shielding or other safety precautions are used. Certain lamps that will automatically extinguish when the outer envelope is broken or punctured are commercially available.???This lamp complies with FDA radiation performance standard 21 CFR subchapter J. (USA:21CFR 1040.30 Canada:
If the outer bulb is broken or punctured, turn off at once and replace the lamp to avoid possible injury from hazardous short wave ultraviolet radiation. Do not scratch the outer bulb or subject it to pressure as this could cause the outer bulb to crack or shatter.A partial vacuum in the outer bulb may cause glass to fly if the envelope is struck.
WARNING: The
DAMAGE, BURNS AND FIRE.
These lamps are designed to retain all the glass particles should an arc tube rupture occur.The following operating instructions are recommended to minimize these occurrences.
RELAMP FIXTURES AT OR BEFORE THE END OF RATED LIFE. Allowing lamps to operate until they fail is not advised and may increase the possibility of inner arc tube rupture.
This lamp contains an arc tube with a filling gas containing
CAUTION: TO REDUCE THE RISK OF PERSONAL INJURY, PROPERTY DAMAGE,
BURNS AND FIRE RESULTING FROM AN
LAMP OPERATING INSTRUCTIONS MUST BE FOLLOWED:
LAMP OPERATING INSTRUCTIONS:
1.RELAMP FIXTURES AT OR BEFORE THE END OF RATED LIFE. Allowing lamps to operate until they fail is not advised and may increase the possibility of inner arc tube rupture.
2.Before lamp installation/replacement, shut power off and allow lamp and fixture to cool to avoid electrical shock and potential burn hazards.
3.Use only auxiliary equipment meeting Philips and/or ANSI standards. Use within voltage limits recommended by ballast manufacturer.
A.Operate lamp only within specified limits of operation.
B.For total supply load refer to ballast manufacturers electrical data.
C.Operate 39W
4.Periodically inspect the outer envelope. Replace any lamps that show scratches, cracks or damage.
5.If a lamp bulb support is used, be sure to insulate the support electrically to avoid possible decomposition of the bulb glass.
6.Protect lamp base, socket and wiring against moisture, corrosive atmospheres and excessive heat.
7.Time should be allowed for lamps to stabilize in color when turned on for the first time.This may require several hours of operation, with more than one start. Lamp color is also subject to change under conditions of excess vibration or shock and color appearance may vary between individual lamps.
8.Lamps may require up to 10 minutes to
9.Take care in handling and disposing of lamps. If an arc tube is broken, avoid skin contact with any of the contents or fragments.