Guarantee

PhilipsAVENT guarantees that should the ISIS iQ UNO Electronic Breast Pump become faulty during twelve months from the date of purchase,it will be replaced free of charge during this time. Please return it to the retailer where it was purchased. Please keep your receipt as a proof purchase,together with a note of when and where purchased.

For the Guarantee to be valid,please note:

The ISIS iQ UNO Electronic Breast Pump must be used according to the instructions in this booklet and connected to a suitable electricity supply or the battery pack provided.

The claim must not be a result of accident,misuse,dirt,neglect or fair wear and tear.

This Guarantee does not affect your statutory rights.

If the retailer is unable to help,please contact Philips AVENT Customer Services.

For our complete catalogue of mother and babycare products

GB:Call FREE on 0800 289 064

UK ONLY (9am???4.30pm Mon-Fri)

IRL:Call FREE on 1800 509 021

IRL ONLY (9am???4.30pm Mon-Fri)

AU: 1300 364 474

www.philips.com/AVENT

AVENT, Suffolk, CO10 7QS, England

Philips of Holland.All logos brands and product names are trademarks or registered trademarks of their respective holders and are hereby recognised as such.

ISIS iQ UNO Breast Pump

421335410490 (05/07)

Warnings and Cautions

When using electrical products, especially when children are present, basic safety precautions should always be followed, including the following.

READALL INSTRUCTIONS BEFORE USINGYOUR PHILIPSAVENT ISIS iQ UNO

BREAST PUMP.

WARNING ???To reduce the risk of fire,electrocution,or other personal injury:

???ISIS iQ UNO is intended for repeated use by a single user only.

???Always unplug from the electrical wall socket immediately after use.

???Do not use while bathing.

???Do not place or store the product where it can fall or be pulled into a bath or sink.

???Do not place or drop the control handle,battery pack or mains power lead into water or other liquids.

??? Do not reach for a product that has fallen into water. Unplug from the wall socket immediately.

???Do not allow children or pets to play with the control handle, battery pack, mains power lead or accessories as these parts may pose a choking or strangulation danger.

???Before each use inspect the product, including mains power lead, for signs of damage. Never operate this product if it has a damaged lead or plug, if it is not working properly or if it has been dropped, damaged or submerged in water.

???Only use attachments recommended by Philips AVENT.

??? Do not use outdoors or where aerosol spray products are being used, or where oxygen is being administered.

???Equipment not suitable for use in the presence of flammable anaesthetic mixture with air, or with oxygen or nitrous oxide.

???Only use the mains power lead and battery pack supplied with the product.

???There are no user serviceable parts inside the ISIS iQ UNO. Do not attempt to open, service or repair the ISIS iQ UNO yourself.

???Keep leads away from heated surfaces.

???This product is a personal care item and should not be shared between mothers.

???Do not attempt to remove the pump body from your breast while under vacuum.Turn the unit off and break

the seal between your breast and the pump funnel with your finger, then remove the pump from your breast.

???Do not operate control handle unless connected to a pump body.

???Never use while pregnant, as pumping can induce labour.

???Never use when sleepy or drowsy.

??? This appliance is intended for use by responsible persons, keep out of reach of small children and the infirm.

???This appliance is not intended for use by persons with reduced physical, sensory or mental capabilities, or lack of experience or knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.

CAUTION ???To reduce the risks of injury, device malfunction or failure:

???The product should not be left unattended when plugged into an electrical socket.

???Never drop or insert any foreign object into any opening.

???Make sure the voltage of the mains power lead is compatible with the power source.

???Plug the end of the wall plug lead into the control handle first,then securely attach the wall plug into the socket.

???Although compliant with applicable EMC directives, this equipment may still be susceptible to excessive emissions and/or may interfere with more sensitive material.

???Wash, rinse and sterilise the appropriate pump parts before each use.

???Never put the control handle, battery pack or lead in water or a steriliser as you can cause permanent damage to the pump.

???Do not continue pumping for more than five minutes at a time if no result is achieved.

???Do not use antibacterial or abrasive cleaners/detergents when cleaning breast pump parts.

???If the pressure generated is uncomfortable or causing pain,turn the unit off,break the seal between the breast and the pump body with your finger and remove the pump from your breast.

1

ISIS iQ UNO Pump Parts Guide

All you need to assemble and use ISIS iQ UNO is shown here. If any of the parts are missing, or if you have any questions, please contact Customer Services (see back page for details).

ISIS iQ UNO Pump Parts Guide ??? Detailed

Troubleshooting Guide

??Avoid contact with antibacterial or abrasive detergents/cleaners as they can damage the plastic. Combinations of detergents, cleaning products, sterilising solution, softened water and

Cracking or

temperature fluctuations may, under certain circumstances, cause

discolouration

Control Handle

??? adjusts the pumping suction, speed and pattern so ISIS iQ can learn and then repeat your rhythm after only 2 compressions.

Power socket

Control button

??? turns pump on and off and automates your pumping rhythm.

Control handle

Light

NEVER STERILISE OR IMMERSE IN WATER

the plastic to crack. If this occurs, do not use.The pump body and

of pump parts

breast milk containers are dishwasher safe but food colourings may discolour them. Follow guidelines in ???Cleaning and Sterilising ISIS iQ UNO??? on page 6.

2

Power cable

Only the following batteries are compatible with the ISIS iQ UNO Battery Pack: Duracell Ultra M3, Duracell Plus, Energizer Ultra Plus, Duracell Accu (NiMH),Ansmann (NiMH). For Duracell Acc (NiMH) & Ansmann (NiMH) use/charge in accordance with manufacturers guidelines. Dispose of batteries as per manufacturers instructions.

NEVER STERILISE OR IMMERSE IN WATER

Congratulations!

Breastfeeding your baby is a wonderful experience. However,there are times when you may need to express your breast milk.At Philips AVENT we have tried to replicate the way your baby feeds,making expressing your milk a comfortable and enjoyable experience. Relax and enjoy the experience because you???re always in complete control.And when you???re relaxed and comfortable, you express more milk, faster.

Intuitive and intelligent... It???s your iQ.

Disassembling ISIS iQ UNO

Before you use your breast pump for the first time and every time before use, you must disassemble and clean the parts as described opposite.

Disassembly

1the pump off by pressing and holding down the

control button until the light goes off. Unplug from the wall socket and disconnect the mains powerIf you have already used your ISIS iQ UNO, turn

or battery pack lead from the control handle.

You can be quite firm when removing

2 the control handle. First pull directly upwards away from the diaphragm. Now unhook it from the stem by moving it towards the funnel.

3Remove the funnel cover and gently pull the Let-down Massage Cushion away from the funnel.

Remove the silicone diaphragm and stem, unscrew

4 the milk container and remove the white valve.

5Need Help? Contact Customer Services (see back page for details)

Cleaning and Sterilising ISIS iQ UNO

Clean with a damp cloth when necessary:

These components DO NOT

come into contact with your

breast milk.

CAUTION: NEVER PUT THE CONTROL HANDLE, BATTERY PACK OR MAINS POWER LEAD

IN WATER OR A STERILISER,ASYOU CAN CAUSE PERMANENT DAMAGE TO THE PUMP.

Disassemble and clean before every use (including first use):

b

Cleaning Instructions:

Wash in warm soapy water and rinse, or wash on the top rack of the dishwasher. Sterilise in a steam steriliser (electronic, electric or microwave) or by boiling in water for 5 minutes before every use.

CAUTION: DO NOT USE ANTIBACTERIAL OR ABRASIVE CLEANERS/DETERGENTS.

TO CLEAN THE VALVE, RUB GENTLY BETWEENYOUR FINGERS IN WARM SOAPY WATER ???

DO NOT INSERT OBJECTS AS THIS MAY CAUSE DAMAGE.

HELPFULTIP!

The Philips AVENT Electronic, Electric and Microwave Steam Sterilisers are designed to hold the washable components of the ISIS iQ UNO and the entire

ISIS Manual Breast Pump.

6

Assembling the pump body of ISIS iQ UNO

Before assembling, make sure that your hands are clean and you have correctly washed and sterilised the pump (see ???Cleaning and Sterilising ISIS iQ??? on page 6).Also check that none of the pump components are damaged.

Parts you will need for steps 1-4:

Insert the white valve into the pump

1 body, so that it fits securely into the small round hole. Make sure the pointed side of the valve is facing down.

7

Assembling the pump body of ISIS iQ UNO

2into the pump body. Ensure a perfect seal around the rim by pressing down with your

fingers. (This is easier if assembled while the diaphragm is wet.)Fit the clear silicone diaphragm with stem

Screw the pump body onto the milk

3 container until securely in place.

To ensure that the pump is completely stable, you can use the stand with the 125ml/4oz milk container.

4secure the rim around the funnel making sure there are no gaps. Run your thumb on the flat surface between each petal to ensure there are

no air pockets. (This is easier if assembled while the Let-down Massage Cushion is wet.)Insert the Let-down Massage Cushion and

HELPFULTIP!

Some women may prefer to use the pump without the Let-down Massage Cushion. It has been shown that in most cases, the massaging effect of the petals flexing in and out around the areola, stimulates the let-down reflex and allows you to express more milk, faster.

Connecting the Electronics of ISIS iQ UNO

Parts you will need for steps 5-7:

Assembled

pump bodyControl handle (see pages 7-8)

Firmly push the control handle onto

5 the pump body so that it sits securely on top of the silicone diaphragm.

9Need Help? Contact Customer Services (see back page for details)

Connecting the Electronics of ISIS iQ UNO

6power lead to the control handle,

plug into an electrical wall socket and switch on.For electric use connect the mains

For battery use, open the top of

i

7 the battery pack and insert 4 x AA batteries. (For a list of compatible batteries, see page 3.)

Connect the power lead

to the control handle.

HELPFULTIP!

Batteries will last for approximately 6 hours.The light on the control handle will display a continuous RED pulsing flash to warn you when it is time to replace them.There will be enough power for approximately 1 more pumping session, with no drop-off in performance, before the pump switches itself off.

10

Hints to help you succeed

Using a breast pump takes practice.You may need to make several attempts before you succeed, but because ISIS iQ UNO is so simple and comfortable to use, you will soon get used to expressing milk.

1.Choose a quiet time when you???re not rushed and unlikely to be disturbed.

2.Having your baby or a photograph of your baby nearby can help encourage your milk to flow.

3.Warmth and relaxation can also help so you might like to try expressing after a warm bath or shower.

4.Placing a warm cloth on your breasts for a few minutes before you start pumping can encourage your milk flow and soothe painful breasts.

5.Try expressing from one breast while your baby is feeding from the other, or continue expressing just after a feed.

6.Repositioning the pump on your breast from time to time can help stimulate your milk ducts.

7.Some women may prefer to use the pump without the Let-down Massage Cushion. However, it has been shown that, in most cases, the massaging effect of the petals flexing in and out around the areola stimulates the let-down reflex and allows you to express more milk, faster.

8.To relieve engorgement, we recommend gentle, slow pumping to relieve the pressure.

Practice with your pump to find the best pumping techniques for you. Don???t worry

if your milk doesn???t flow immediately, relax and continue pumping.

CAUTION: IF AFTER 5 MINUTES NO RESULT IS ACHIEVED,TRY AGAIN AT ANOTHER TIME

OF DAY. IFYOU EXPERIENCE ANY PAIN IN THE BREAST AREA, STOP AND CONSULTYOUR

BREASTFEEDING ADVISOR.

How much milk can you expect?

On average you will need to pump for 10 minutes to express 60-125mls or 2-4ozs of milk. However, this is just a guide and varies from woman to woman. If you find that you regularly express more than 125mls/4ozs of milk per session, attach a 260ml/9oz milk container to the pump body.

11

Expressing with ISIS iQ UNO

Before you begin pumping, make sure that you have correctly washed, sterilised and assembled the pump. Consult the ???Hints to help you succeed??? opposite for tips on stimulating let-down and milk flow.Wash your hands thoroughly and make sure your breasts are clean. Relax in a comfortable chair and lean slightly forward so that your milk flows easily down the pump funnel into the milk container (you can use cushions to support your back).

1handle and plug into an electrical wall socket if necessary. Press and hold the control button until the light flashes ORANGE and you hear the pump turn on (this can take up to 5 seconds). Once the light turns solid GREEN, the pump is ready to use.

If the light is flashing RED,refer to the ???Troubleshooting Guide??? on pages 19-20.Turn on pump: Connect the power lead to the control

2breast to form a complete seal, ensuring that your nipple fits into the funnel. Check you have a reliable vacuum

by compressing and releasing the control handle so you can feel suction.Create a reliable vacuum: Press the pump against your

HELPFULTIP!

Control Handle Light

Flashing ORANGE ??? Control Handle Setting Up

Solid GREEN ??? Motor Ready/Pump in Manual

Control Mode

Flashing GREEN ??? Pump in Automatic Mode

Flashing RED ??? Warning

(seeTroubleshooting Guide on pages 19-20)

Expressing with ISIS iQ UNO

3the handle in a way that feels comfortable and similar to your baby???s initial rapid suckling action.The petals on the Let-down Massage Cushion will flex in and out around the areola, creating a massaging effect, similar to baby???s natural mouth and jaw movements during breastfeeding.You can choose to automate this let-down phase by pressing the control button after two compressions (flashing GREEN light). Once your milk begins to flow, press the control button to return to manual control (solid GREEN light).

CAUTION:LET-DOWN CAN OCCUR IMMEDIATELY,EVEN AFTER

JUST A FEW STROKES AND SHOULD NOTTAKE LONGERTHAN 5 MINUTES (REFERTO HINTSTO HELPYOU SUCCEED ON PAGE 11).Initiate let-down:To encourage let-down,lightly press

4Milk expression:To create a natural and effective breast pumping rhythm that can be maintained for the rest

of your pumping session,compress the handle slowly and more fully (to increase the intensity of the suction), hold for 2-3 seconds and then slowly release. Once you are happy with the level of suction and rhythm, after two compressions,press the control button and ISIS iQ will continue your personal pumping rhythm (flashing GREEN light).

Note:You do not need to compress the handle fully, only until it feels comfortable.The further you compress the handle, the more suction the pump will provide. If the pressure is uncomfortable, stop and change your pumping rhythm.

HELPFULTIP!

Let-down is your body???s physiological response to the suckling action of your baby on the breast.This stimulates the breast to produce milk and send it towards the nipple where it is available for baby.

Milk expression occurs after let-down is achieved and milk begins to flow. It is the phase that is induced by the baby???s deeper more comfortable suckling rhythm.

Expressing with ISIS iQ UNO

5Changing or ending your automated pumping session:

To change your pumping rhythm at any time, press the control button to revert to manual control (solid GREEN light) and set a new pattern.

To end your pumping session, press the control button to revert to manual control (solid GREEN light). Break the seal between your breast and the pump funnel with your finger and remove the pump from your breast.Turn the pump off by pressing and holding the control button until the light goes off. Remove the plug from the electrical socket if necessary, then remove the power lead from the control handle.

6Storing your milk: Make sure that you have not over-filled the milk container and carefully unscrew

it from the pump body.Add a sterilised screw ring and sealing disc to safely store your breast milk in the refrigerator or freezer.

Next time you turn your pump on:

7 Resuming saved session? Even after ISIS iQ is turned off, it will remember the last programmed rhythm. If you have had a short break and your milk is still flowing, ensure you have a good seal against your breast, press the control button and ISIS iQ will continue as before.

Need to re-establish let-down? If you need to re-establish let-down, refer to the beginning of ???Expressing with ISIS iQ UNO???on page 12.

CONSULTTHE GUIDELINES FOR STORING EXPRESSED BREAST MILK ON PAGE 17

14

Using your ISIS iQ UNO as a manual breast pump

ISIS Manual Breast Pump ??? parts guide

Your ISIS iQ UNO can also be used as a manual pump. In this case, you simply need to replace the control handle with the manual handle and pump cover included in a separate bag.

p Pump cover

q Handle

Assembling your ISIS Manual Breast Pump

Ensure you have disassembled, washed and sterilised all the parts (see Cleaning Instructions on page 6) and then follow steps 1-4 as described on pages 7-8:

But this time:

Position the forked end of the handle (q) under

45 the diaphragm stem and push down gently

on the handle until you hear it ???click??? into place.

64 Click the pump cover (p) onto the pump body.

15

Using your ISIS iQ UNO as a manual breast pump

Before you begin pumping, make sure that you have correctly washed, sterilised and assembled the ISIS Manual Breast Pump. Consult the ???Hints to help you succeed??? section on page 11 for tips on stimulating let-down and milk flow.Wash your hands thoroughly and make sure your breasts are clean. Relax in a comfortable chair and lean slightly forward so that your milk flows easily down the pump funnel into the milk container (you can use cushions to support your back).

1 Create a reliable vacuum: Press the pump against your breast to form a complete seal, ensuring that your nipple fits into the funnel. Check you have a reliable vacuum by compressing and releasing the handle so you can feel suction.

2the handle in a way that feels comfortable and similar to your baby???s initial rapid suckling action.

CAUTION: LET-DOWN CAN OCCUR IMMEDIATELY, EVEN

AFTER JUST A FEW STROKES AND SHOULD NOT TAKE

LONGER THAN 5 MINUTES (REFER TO HINTS TO HELP YOU SUCCEED ON PAGE 11).Initiate let-down:To encourage let-down, lightly press

3pumping rhythm that can be maintained for the rest of your pumping session, compress the handle slowly and more fully (to increase the intensity of the suction), hold for 2-3 seconds and then slowly release.

Note:You do not need to compress the handle fully, only

until it feels comfortable.The further you compress the handle, the more suction the pump will provide.Milk expression:To create a natural and effective breast

4over-filled the milk container and carefully unscrew it from the pump body.Add a sterilised screw ring

and sealing disc to safely store your breast milk in the refrigerator or freezer.Storing your milk: Make sure that you have not

CONSULTTHE GUIDELINES FOR STORING EXPRESSED BREAST MILK ON PAGE 17

Storing your expressed breast milk

Philips AVENT products are interchangeable, so you can express, store and feed with the same container, preserving valuable nutrients that can get lost if breast milk is transferred.

After expressing milk into an AVENT Breast Milk Container, insert a sealing disc into the screw ring and twist onto the container.To feed, just replace the sealing disc with an AVENT Airflex Teat.

Guidelines for storing expressed breast milk

Breast milk can be stored in the fridge or freezer in either sterile AVENT Breast Milk Containers (125ml/4oz or 260ml/9oz fitted with sealing discs) or in pre-sterilisedVIA Cups.

Do not overfill the milk container and be sure to keep it upright.

Expressed milk should be refrigerated immediately.

Only milk collected with a sterile pump should be stored to be fed to your baby.

Expressed breast milk can be stored in the refrigerator for up to 48 hours (not in the door) or in the freezer for up to 3 months.

If you are storing freshly expressed milk in the fridge to add to during the day, only add milk which has been expressed into a sterile container. Milk can only be kept like this for a maximum of 48 hours from first expression, after which it must be used immediately or frozen for future use.

Frozen breast milk can be defrosted overnight in the refrigerator, heated gradually in warm water or heated on the lowest setting of the Philips AVENT Bottle and Baby Food Warmer. Never heat milk in a microwave as this may destroy valuable nutrients and antibodies and uneven heating could cause hot spots.

NB: NEVER refreeze breast milk. DO NOT add fresh breast milk to already frozen milk. ALWAYS discard any milk that is left over at the end of a feed.

CAUTION: NEVER IMMERSE A FROZEN MILK CONTAINER OR VIA CUP IN BOILING WATER

AS THIS MAY CAUSE IT TO CRACK/SPLIT.

Keeping your pump sterile and compact for travel

After sterilising all parts insert the white valve and fit the diaphragm with stem onto the pump body. Clip

nthe funnel cover over the Let-down Massage Cushion and screw the sealing base onto the bottom of the

d

g

h

pump body.

Key to Control Handle Symbols

Technical Specifications

18

Troubleshooting Guide

?? Check for any damaged pump parts and replace if necessary.

?? Check that all the pump components have been assembled correctly and that the white valve is positioned correctly.

?? Ensure that the silicone diaphragm and Let-down Massage Cushion

Lack of, or no suction

are fitted securely to the pump body and that a perfect seal is

created around your breast.

19