NP03Wi Interactive White Board Kit

SOFTWARE MANUAL

This manual describes installation and operation procedures of the driver / the calibration software for NP03Wi Interactive White Board Kit

1

Operating Environment

Supported OSs are as follows:

Windows 7, Windows 8/8.1

*For starting up the software, Microsoft .NET Framework 4 or later is required.

Download the Microsoft .NET Framework from the website of Microsoft and install it onto the computer.

About trademarks

Microsoft, Windows, .NET Framework are either registered trademarks or trademarks of Microsoft Corporation in the U.S. or other countries.

Setup Procedure

Perform setup operations in below steps:

Install the software onto the computer

Startup the software

Perform calibration

Install the Software onto the Computer

IMPORTANT

???When installing / uninstalling the software, you must log on the computer with Administrator's privileges.

???Before starting to install the software, quit all application software in running. If other application software is remained in running, installation may not be completed properly.

???If the displayed language on your OS is not one of correspondent languages for this software, all indications are displayed in English

How to install this software

1.Download the software.

Access to our projector support page in our website with the below URL: http://www.nec-display.com/dl/en/index.html

Find the software for the Interactive White Board Kit, NP03Wi, download and install it onto the computer according to the displayed instructions.

2.Double click [SETUP_NEC_IWB.msl].

The Setup window is displayed.

3.Click [Next>].

Displays the Terms of Use screen.

2

4. Select???I accept the terms in the License Agreement???and click ???Next ??????

Displays the selection screen of the installation destination folder.

5.Click [Next>].

After that, follow the displayed instructions to complete installation.

When the installation is complete, an IWB icon is added to the desktop.

3

How to uninstall the software

1.Click [Control Panel] in the start menu, and double-click [Add or Remove Programs].

2.Right-click [NP03Wi IWB] and click [Uninstall] in the list.

After that, follow the displayed instructions to complete uninstallation.

3. When uninstallation is completed properly, reboot the computer.

4

Startup the Software

Preparation:

???First of all, perform setup according to the installation manual enclosed with NP03Wi.

If the computer and the camera unit are not connected by a USB cable, the message at right would be displayed on and the software would not be started up.

???For starting up the software, Microsoft .NET Framework 4 or later is required.

If Microsoft .NET Framework is not installed on the computer, visit the website of Microsoft for download and install it on the computer.

1.Double click the IWB icon on the desktop.

Driver installation message is displayed on.

Click???OK???and follow the displayed instructions for the sequel operations.

Calibration Menu Display

Right click icon in the task tray and select [Exit] for ???nishing IWB.

5

Performing Calibration

Before starting to use the stylus pen, make sure to perform calibration in order to make the computer to recognize exact position of the stylus pen.

Automatically calibrate the stylus pen position. Recommend this when easy calibration is

Automatic calibration

preferred.

Manually calibrate the stylus pen position. Recommend this for installing the projector

Manual calibration

permanently or when precise calibration is preferred.

Perform Calibration Automatically [Automatic Calibration]

Click the [Start Automatic] button on the displayed calibration menu.

Projected image on the screen will be switched to the Automatic Calibration Screen.

After ???ve to eight seconds, calibration will be completed and the screen will return to display the projected image.

Note:

???If the message in below is displayed on the screen, refer to the Troubleshooting on page 7 and check if the screen is installed within the recognition area of the camera and if the camera and the screen get influence of external light.

Perform Calibration Manually [Manual Calibration]

Press briefly on the red dot to calibrate (see top left)

Press [ESC] to cancel calibration

Press [b] to undo last point

6

2.Press the center of the red dot with the stylus pen.

The red dot is indicated at 25 points in order on the screen.

Press briefly on the red dot to calibrate (see top left)

Press [ESC] to cancel calibration

Press [b] to undo last point

When all points indicated by the red dot are pressed by the stylus pen, calibration is completed and the calibration completion message is displayed on.

3. Touch icon in the task tray by the stylus pen.

This message is popped up when calibration is completed properly.

Note:

???When???Auto Run???in the troubleshooting screen is checked, the software starts automatically when the computer is started up.

???Drawing software is required to use the interactive white board function.

Drawing software cannot be downloaded from our projector support page, prepare commercially available drawing software.

7

Troubleshooting

You can check the installation condition of the camera unit when the troubleshooting in the IWB setup menu is displayed on.

Troubleshooting screen

Switch to the calibration menu

Enable/disable the Auto Run function.

When this function is checked, the software starts automatically when the computer is started up.

Change the stylus pen status. If clicking / pressing this by the

mouse / the stylus pen when PAUSE CALIBRATION is indicated on this button, the stylus pen becomes unavailable.

If clicking this by the mouse when RESUME CALIBRATION is indicated on this button, the stylus pen becomes ready to use.

???Check the camera recognition area

Press four corners of the projection screen by the stylus pen.

A red square is indicated on the troubleshooting screen and it can be checked all area of the screen surface is in the camera recognition area.

???Check in???uence of external light

If the camera and/or the screen is exposed to strong light, it may cause of malfunction because the computer cannot recognize the stylus pen. If a red square is indicated on the screen without touching the screen by the stylus pen, it means the camera and/or the screen get in???uence of external light. In this case, change the place to install them avoiding to receive direct sunshine or strong light.

Others