No part of this publication may be reproduced or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written consent of the publisher. Information in this manual is furnished under license and may only be used in accordance with the terms of the software license. This publication and the information herein is furnished AS IS, is subject to change without notice, and should not be construed as a commitment by Motorola. Motorola assumes no responsibility or liability for any errors or inaccuracies, makes no warranty of any kind (expressed, implied, or staory) with respect to this publication, and expressly disclaims any and all warranties of merchantability, fitness for particular purposes, and noninfringement of third-party rights.

Companies, names, and data used in the examples herein are fictitious unless otherwise noted.

Pass-Through Licenses:

Net-SNMP and LwIP source code are provided under the terms of their respective license agreements.

Source code and copyright notices are available from Motorola support. email: pbn.support@motorola.com

Copyright ?? 2005-2006 Motorola, Inc. All rights reserved.

???Motorola??? is a registered trademark of Motorola, Inc. in the United States and in other countries.

Other trade names used in this document are trademarks or registered trademarks of the manufacturers or vendors of the associated products.

Motorola, Inc.

5200 Franklin drive, Suite 100 Pleasanton, CA 94588

1 (925) 201-4500 main

1 (925) 201-4509 fax

1 (800) 998-4888 www.systems.com

Published in the United States of America August, 2007

T3 PowerBroadband User Guide

Text part number: 570510-001-00 rev A

Regulatory Statements

Model Number:45225

45101

Radio Frequency Interference Requirements- FCC

Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Radio Frequency Interference Requirements- Canada

This Class A digital apparatus complies with Canadian ICES-003.

Cet appareil num??rique de la classe A est conforme ?? la norme NMB-003 du Canada.

Marking and European Economic Area (EEA)

WARNING: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

Statement of Compliance

Motorola/Symbol hereby declares that this device is in compliance with all the applicable Directives, 2004/108/EC and 2006/95/EC. A Declaration of Conformity may be obtained from http://www2.symbol.com/doc/.

Wireless Device Country Approvals

For 2.4GHz or 5GHz Products: Europe includes, Austria, Belgium, Bulgaria, Czech Republic, Cyprus, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Liechtenstein, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovak Republic, Slovenia, Spain, Sweden, Switzerland and the United Kingdom.

Operation of the device without regulatory approval is illegal.

Frequency of Operation ??? FCC and IC

2.4 GHz Only

The available channels for 802.11 b/g operation in the US are Channels 1 to 11. The range of channels is limited by firmware.

RF Exposure Guidelines

Safety Information

Reducing RF Exposure ??? Use Properly

Only operate the device in accordance with the instructions supplied.

International

The device complies with internationally recognized standards covering human exposure to electromagnetic fields from radio devices. For information on ???International??? human exposure to eletromagnic fields refer to the Motorola/Symbol Declaration of Conformity (DoC) at http://www2.symbol.com/doc/.

EU

Remote and Standalone Antenna Configurations

To comply with EU RF exposure requirements, antennas that are mounted externally at remote locations or operating near users at stand-alone desktop of similar configurations must operate with a minimum separation distance of 20 cm from all persons.

FCC

Remote and Standalone Antenna Configurations

To comply with FCC RF exposure requirements, antennas that are mounted externally at remote locations or operating near users at stand-alone desktop of similar configurations must operate with a minimum separation distance of 20 cm from all persons.

To satisfy FCC RF exposure requirements, a mobile transmitting device must operate with a minimum separation distance of 20 cm or more from a person???s body.

Radio Frequency Interference Requirements- FCC

Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Radio Transmitters (Part 15)

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Radio Frequency Interference Requirements- Canada

This Class A digital apparatus complies with Canadian ICES-003.

Cet appareil num??rique de la classe A est conforme ?? la norme NMB-003 du Canada.

Radio Transmitters

This device complies with RSS 210 of Industry & Science Canada. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation.

Label Marking: The Term "IC:" before the radio certification only signifies that Industry Canada technical specifications were met.

Marking and European Economic Area (EEA)

WARNING: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

The use of 2.4GHz WLAN???s, for use through the EEA, have the following restrictions:

???Maximum radiated transmit power of 100 mW EIRP in the frequency range 2.400 -2.4835 GHz.

???France, outside usage is restricted to 2.4 ??? 2.454 GHz.

???Italy requires a user license for outside usage.

Statement of Compliance

Motorola/Symbol hereby, declares that this device is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. A Declaration of Conformity may be obtained from http://www2.symbol.com/doc/.

IMPORTANT SAFETY INSTRUCTIONS

T2-2500 and T3 Switch

CAUTION: For installation only in a Restricted Access Location by trained service personnel.

CAUTION: Equipment must be connected to an earthed mains socket-outlet.

CAUTION: To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cord.

CAUTION: The power supply cord plug serves as the main disconnect for the product. The socket-outlet shall be installed near the product and be readily accessible.

CAUTION: Voltages present which are above TNV-3 (POTS) limits. A cover must be installed over the punch down blocks with a HV (High Voltage) warning label (supplied).

The maximum operating ambient temperature is 50 degrees Celcius.

When installing the Switch in an equipment rack, consider the following potential hazards:

Elevated Operating Ambient Temperature ??? If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than the room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer???s maximum rated ambient temperature (Tmra).

Reduced Air Flow ??? Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised.

Mechanical Loading ??? Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading.

Circuit Overloading ??? Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.

Reliable Earthing ??? Reliable earthing of rack-mounted equipment should be maintained.

Particular attention should be given to supply connections other than direct connections to the branch circuit (e.g., use of power strips).

m2 WallPlate

CAUTION: Use only power supplies listed in the user manual

When using your telephone equipment, basic safety precautions should always be followed to reduce the risk of fire, electric shock and injury to persons, including the following:

1.Do not use this product near water, for example, near a bath tub, wash bowl, kitchen sink or laundry tub, in a wet basement or near a swimming pool.

2.Avoid using a telephone (other than a cordless type) during an electrical storm. There may be a remote risk of electric shock from lightning.

3.Do not use the telephone to report a gas leak in the vicinity of the leak.

SAVE THESE INSTRUCTIONS

Waste Electrical and Electronic Equipment (WEEE)

English: For EU Customers: All products at the end of their life must be returned to Motorola for recycling. For information on

how to return product, please go to: www.motorola.com/recycling/weee.

Bulgarish: ???? ?????????????? ???? ????: ???????? ???????? ???? ???????????????? ???? ?????????? ???????????? ???????????????? ???????????? ???? ???? ???????????? ???? Motorola ???? ??????????????????????. ???? ???????????????????? ?????????????? ?????????????????? ???? ????????????????, ???????? ?????????????? ???? ??????????: www.motorola.com/recycling/weee.

Dansk: Til kunder i EU: Alle produkter skal returneres til Motorola til recirkulering, n??r de er udtjent. L??s oplysningerne om

returnering af produkter p??: www.motorola.com/recycling/weee.

Deutsch: F??r Kunden innerhalb der EU: Alle Produkte m??ssen am Ende ihrer Lebensdauer zum Recycling an Motorola

zur??ckgesandt werden. Informationen zur R??cksendung von Produkten finden Sie unter: www.motorola.com/recycling/weee.

Eesti: EL klientidele: k??ik tooted tuleb nende eluea l??ppedes tagastada taaskasutamise eesm??rgil Motorola'ile.

Lisainformatsiooni saamiseks toote tagastamise kohta k??lastage palun aadressi: www.motorola.com/recycling/weee.

Espa??ol: Para clientes en la Uni??n Europea: todos los productos deber??n entregarse a Motorola al final de su ciclo de vida para que sean reciclados. Si desea m??s informaci??n sobre c??mo devolver un producto, visite: www.motorola.com/recycling/weee.

Fran??ais : Clients de l'Union Europ??enne : Tous les produits en fin de cycle de vie doivent ??tre retourn??s ?? Motorola pour

recyclage. Pour de plus amples informations sur le retour de produits, consultez: www.motorola.com/recycling/weee.

Italiano: per i clienti dell'UE: tutti i prodotti che sono giunti al termine del rispettivo ciclo di vita devono essere restituiti a Motorola al fine di consentirne il riciclaggio. Per informazioni sulle modalit?? di restituzione, visitare il seguente sito Web: www.motorola.com/recycling/weee.

Magyar: Az EU-ban v??s??rl??knak: Minden t??nkrement term??ket a Motorola v??llalathoz kell eljuttatni ??jrahasznos??t??s c??lj??b??l. A term??k visszajuttat??s??nak m??dj??val www.motorola.com/recycling/weee.

Nederlands: Voor klanten in de EU: alle producten dienen aan het einde van hun levensduur naar Motorola te worden teruggezonden voor recycling. Raadpleeg www.motorola.com/recycling/weee voor meer informatie over het terugzenden van producten. www.motorola.com/recycling/weee.

Portugu??s: Para clientes da UE: todos os produtos no fim de vida devem ser devolvidos ?? Motorola para reciclagem. Para

obter informa????es sobre como devolver o produto, visite: www.motorola.com/recycling/weee.

Rom??nesc: Pentru clien??ii din UE: Toate produsele, la sf??r??itul duratei lor de func??ionare, trebuie returnate la Motorola pentru

reciclare. Pentru informa??ii despre returnarea produsului, accesa??i: www.motorola.com/recycling/weee.

Slovenski: Za kupce v EU: vsi izdelki se morajo po poteku ??ivljenjske dobe vrniti podjetju Motorola za recikla??o. Za

informacije o vra??ilu izdelka obi????ite: www.motorola.com/recycling/weee.

Suomi: Asiakkaat Euroopan unionin alueella: Kaikki tuotteet on palautettava kierr??tett??v??ksi Motorola-yhti????n, kun tuotetta ei

en???? k??ytet??. Lis??tietoja tuotteen palauttamisesta on osoitteessa: www.motorola.com/recycling/weee.

Svenska: F??r kunder inom EU: Alla produkter som uppn??tt sin livsl??ngd m??ste returneras till Motorola f??r ??tervinning. information om hur du returnerar produkten finns p?? www.motorola.com/recycling/weee.

Commands and Syntax

Commands and Syntax

The Motorola T3 PowerBroadband system can be managed via a Command Line Interface, webUI, and SNMP. Commands that apply to remote WallPlates, such as Ethernet port configurations and wireless interface, are all entered on the T3 Switch.

Command Hierarchy

The Command Line Interface (CLI) implements a hierarchical command structure. Commands are organized as a high-level command keyword related to a particular function of the device with sub-commands related to sub- functions.

You may move down in the command hierarchy by entering root keywords and sub-keywords followed by the enter key. Your current level in the command hierarchy is referred to as the ???command context.??? The top-level context is referred to as the ???root command context.??? You may move up to the previous command context by using the exit command. The command prompt is the system name, followed by the current command context.

For example, the root command prompt with the default configuration is:

system>

Full commands may be entered at the root command context. For example:

system> interface dsl enable port1

You may also move down levels in the command hierarchy, which allows you to execute commands with less repetitive typing.

For example:

system> interface system:interface> dsl system:interface.dsl> enable port1 system:interface.dsl> enable port3 system:interface.dsl> enable port3 system:interface.dsl> exit system:interface> exit

system>

Administrative Commands

Most commands discussed in this guide are administrative commands, which change the configuration of the system or affect the operation of the system. These commands can only be executed from the admin account. Configuration changes take affect immediately and are recorded in non-volatile memory (NVRAM) in the default mode. Alternatively, you may choose not to record changes in NVRAM. In this case, changes will need to be committed before rebooting the system; otherwise the configuration will revert to the last saved configuration. If automatic commit is enabled, or the configuration is manually committed, the running configuration will automatically be restored if the system power cycles or is rebooted.

Show Commands

The show commands are used to view configurations, status and/or statistics. These commands can be issued from either the user or admin account.

Commands and Syntax

Global Commands

Commands that are available from any command context are called global commands. For example, the help command can be used whether you are at the root command context or down a few levels in the command hierarchy. Global commands can also be used from either the user or admin account.

Note: The default prompt is ???system>???. If you set the system name using the ???system name??? command, the prompt changes to the new system name.

Command Completion

The CLI allows you to shorten commands as long as the characters are not ambiguous. While typing a command, press the tab key to have the system complete the current command word or type (?) to have the system display a list of available options. The options displayed vary according to the context:

???If you type a ? at a prompt, the system displays a list of all available commands.

???If you type an unambiguous command word, pressing ? displays all available subcommands or arguments. For example, show ? (note the space before the question mark) displays a list of all show subcommands.

Style Conventions

The style conventions used in this manual distinguish various elements of the commands and facilitate the proper interpretation of command syntax, parameters, and their use.

interface wireless enable <radio<1-25>(interface-id)>

where;

???radio??? is a keyword and must be typed

<1-25> is a port range parameter for the wireless radio connected to the DSL line (interface-id) is a description and is not typed

Proper command form:

interface wireless enable radio5

wifi wlan enable <wlan<1-25>-<1-16>(interface-id)>

Commands and Syntax

where;

???wlan??? is a keyword and must be typed

<1-25> is the port range for the radio connected to the DSL line <1-16> is the port range of the WLAN on the radio (interface-id) is a description and is not typed

Proper command form:

wifi wlan enable wlan25-1

Note that range commands can also be used. In the following example, WLANs 1, 2, 3 are enabled on all radios.

wifi wlan enable wlan(1-25)-(1-3)

This document refers to actual command syntax as little as possible. For a complete command syntax document, please refer to the Command Reference guide for a complete list of all available commands, the proper syntax, and usage examples. In no way does this User Guide attempt to replace or obsolete the Command Reference.

Interface Range

Multiple interfaces can be specified for a single command using port ranges. Use hyphens (-) and commas (,) to delineate ports. Port numbers must be contained in parenthesis. Hyphens and commas can be combined in the same expression to specify multiple, non-sequential interfaces. For example;

To enable all 25 DSL ports, type: interface dsl enable port(1-25)

To enable only selected DSL ports, type: interface dsl enable port(1,3,5,20-25)

Hyphens and commas can also be used to enable remote Ethernet ports along with DSL ports. For example;

To enable Eth1 and Eth2 on every WallPlate, type: interface remote enable port(1-25)-(1,2)

VLAN commands can also be completed using interface ranges.

To add VLAN 100 to Eth1 on every WallPlate, type: vlan membership add 100 interface port(1-25)-1

System Description

System Description

The T3 PowerBroadband system is designed primarily for hospitality, but useful in any high density MDU (multiple dwelling unit) such as long term healthcare or centrally wired apartments. The system is comprised of two primary components; a 25-port Switch and a CPE device (the WallPlate). Advanced networking features such as 802.1Q VLANs and QoS can be managed throughout the system, from the 25-port switch to each port on the WallPlate.

Adaptive Line Power

T3 PowerBroadband delivers operating power to the remote WallPlates.

T3 PowerBroadband Switch

The T3 switch is installed in a centrally located phone room; where all the telephone wires converge. The T3 switch has 25 ports for downstream WallPlates, and 2 x GigE uplink ports.

T3 PowerBroadband Switch:

Physical

???17.50"(43.8mm) x 14.25" (36mm) x 1.75" (44mm). 11.5lbs (5.2Kg)

???Operating Temperature: 0 - 50 degrees Celsius, 5% to 90% NC

???Operating Power: 300W maximum under full load, 200W typical

Interfaces

???Uplink ports

oTwo 10/100/1000Mb autosensing, full duplex Ethernet ports via RJ45

???Downlink ports

o25 VDSL UTP ports via RJ21 telco connector

Layer-2 Networking Features

???802.1Q VLAN trunk ports

???802.1Q PVID per port

???Port-based Isolation VLANs

???QoS, 4 queues per port, classification by IP-TOS or L2-COS bit

???IGMP, Layer 2+ routing, proxy, FastLeave

???1024 entry MAC forwarding table

Management

???Telnet, Console, webUI, Syslog, SNMPv2c

???RADIUS authentication, Admin and User level login

???Security: L2 VLAN, IP ACL

M2 Ethernet WallPlate

The m2 Ethernet WallPlate has two 10/100Mb Ethernet ports, and a pass-through RJ11 phone connector. It is installed at the end-point where Ethernet service is desired. It operates over a standard 2-wire telephone line.

System Description

M2 Ethernet WallPlate:

Physical

???5"(mm) x 3.5" (mm) x 1.25" (32mm)

???Operating Temperature: 0 - 40 degrees Celsius, 5% to 90% NC

???Operating Power: approximately 2W, line powered by the T3 Switch

Interfaces

???Uplink ports

oOne VDSL single wire pair port via RJ11 jack

???Downlink ports

oTwo 10/100Mb autosensing, full duplex Ethernet port via RJ45 jack

oOne pass-through filtered phone port via RJ11 jack

Layer-2 Networking Features

???802.1Q VLAN trunk ports

???802.1Q PVID per port

???QoS, 2 queues per port, port based classification

Management

???Embedded Layer-1 channel for device management from T3 Switch

MC-802 Wireless WallPlate

The MC-802 Wireless WallPlate has two 10/100Mb Ethernet ports, a pass-through RJ11 phone connector, and a managed 802.11b/g radio. It is installed at the end-point where Ethernet and/or Wireless service is desired. It operates over a standard 2-wire telephone line.

Features of the MC-802 802.11b/g radio:

Physical

???6.625"(168mm) x 3.75" (95.25mm) x 1.75" (44.45). lbs (Kg)

???Operating Temperature: 0 - 40 degrees Celsius, 5% to 90% NC

???Operating Power: approximately 6W, line powered by the T3 Switch

Interfaces

???Uplink ports

oOne VDSL single wire pair port via RJ11 jack

???Downlink ports

oTwo 10/100Mb autosensing, full duplex Ethernet port via RJ45 jack

oOne 802.11b/g radio

oOne pass-through filtered phone port via RJ11 jack

Layer-2 Networking Features

???802.1Q VLAN trunk ports

???802.1Q PVID per port

???QoS, 4 queues per port

Management

???Embedded Layer-1 channel for device management from T3 Switch

???Layer-3 IP addresses from private pool or public pool

???All management centralized on T3 Switch

System Description

Radio

???802.11b/g

oBeacon frame control

oProbe request response

oBroadcast on/off per SDID

oListen mode client support

oDSS/OFDM modulation via 2.4Ghz transmitter

oRegulatory Domain: FCC Part 15c 15.247 and ETS 300 328

???Transmit power: 20dBm transmitter

oCustomer configurable: 1 ??? 14, max. In 1dBm increments

oMax transmit power of 20dBm depends on regulatory country

???Two integrated omni-directional antennas

o3.2dBi

oAntenna receive diversity

???Security Protocols ??? (per SSID)

oWireless Client Isolation

oEAP types: TLS, PEAPv0, TTLS

oAES, TKIP encryption

???QoS

oWireless Multimedia (WMM) priority

oWMM power save

oSpectralink ready

???Virtual AP mode

oConcurrent BSS (16)

o Per-BSS SSID

oPer-BSS client isolation

oPer-BSS 802.1Q VLANs

oPer-BSS authentication/encryption

oPer-BSS bitrate

???Two runtime images in flash, realtime firmware upgrade

???Client state, status and statistics

oMAC address of client

o Client link rate

o Client link strength (dBm) o Packets tx/rx

o Authentication status o SSID

oMAC address

???WLAN state information

oSignal strength and MAC of other APs

oTx signal strength

oPacket Tx/Rx statistics

Hardware

Hardware

Model Numbers and Description

The T3 PowerBroadband Switch is compatible with both the Wireless and Ethernet WallPlates. Both can be mixed together on the same T3 PowerBroadband Switch.

Model Numbers and Description for related Products

Filters are required for proper in-room installation. Installation may also use one or more of the following additional products.

Hardware

T3 PowerBroadband Switch

Front View

Rear View

Cross-Connect Connections

T3 PowerBroadband Switch

Mounting Options

T3 ships with mounting ears designed for a standard EIA-19 equipment rack. The ears can be rotated 180 degrees.

Hardware

MC-802 Wireless WallPlate

Designed to be installed over existing RJ11 wall jack. Ships with Adapter plate for standard 70mm x 114mm RJ11 wall jack.

Eth1 ??? 10/100 auto-sensing Ethernet

Eth2 ??? 10/100 auto-sensing Ethernet

RJ11 filtered phone port

DC power connector (used during installation, not under normal operation)

LED Status Lights

m2 ??? 2 port Ethernet WallPlate

Designed to be installed over existing RJ11 wall jack. Bracket has a large opening to route the RJ11 cable from the existing jack. See Installation Chapter for a breakout view of the cover and bracket.

Hardware

DC power connector (used during installation, not under normal operation)

RJ11 filtered phone port

Eth1 ??? 10/100 auto-sensing Ethernet

Eth2 ??? 10/100 auto-sensing Ethernet

RJ11 line-in port (not shown, accessible when bracket is removed)

System Administration

System Administration

This User Guide covers the commands relevant to the T3 PowerBroadband Switch. For a complete set of commands and information, consult the T3 PowerBroadband Command Reference.

Management Access

T3 can be managed via serial console, telnet, HTTP webUI, or SNMP. Eth1 is enabled by default. Telnet and HTTP are accessible at the default IP address.

Access Methods

Default login and password

CLI Configuration Script files

T3 file system stores and load configuration script files. These files are text editable. Use the following commands to complete these management tasks:

1.Create a starting configuration file from an existing T3 switch

2.Copy the file to an external server

3.Edit the file on a PC

4.Load the file into another T3 switch

5.Execute the file as a set of configuration commands

The command syntax to use the file system is:

file copy <string(source)> to <string(destination)>

a.Source can be a local file, a remote FTP or TFTP file, or a pre-defined keyword. Keywords allow you to capture the startup and running configuration to a file. Supported keywords are ???startup??? and ???running???.

b.Destination can be a local file or a remote FTP or TFTP file. Note that the combination of the Source keywords and the remote Destination allows you to copy the running config directly to a remote server. For example; file copy running to tftp://192.168.1.1/my-t3-config.txt

c.At least one (source or destination) must be the local file system. If the source and destination are remote servers, the command will fail.

System Administration

file delete <string(file)>

d.Delete a file from the file system

file dir

e.List the files in the system and display the remaining storage file exec <string(file)>

f.Executes a file as a set of configuration commands. Note that ???file??? is a local file in the file system. The file must have previously been copied to the filesystem from the external server using the file copy command.

Configuration Files using the webUI

From the webUI, the administrator can save and load configuration files. Note that these configuration files are non-editable binary format for configuration security. If editable configuration is desired, use the CLI script files. Configuration files from the webUI can be used to create secure template configurations.

Note: The Configuration File contains every configuration possible including the ???Admin??? account password. When combined with RADIUS network authentication, the non-editable Configuration Files provide a secure method to pre-configure systems in a staging area and apply the secure ???admin??? password without revealing the password. Contact a Motorola support person for assistance with a setting up secure, staged configurations.

To save or load a Configuration file from the webUI, access the System ??? Configuration screen from the webUI.

Follow these steps to create a template configuration file:

1.Configure a complete system configuration

2.Set the system name to ???template configuration??? or similar name

3.Save the configuration file using the webUI System-Configuration screen

Follow these steps to apply the template to a new system:

1.Boot a new system

2.Using the serial console login, set the IP address (or use the default IP address)

3.Reboot the system to apply the IP address

4.Login via the webUI

5.Load the template configuration file using the System-Configuration screen

6.Change the system name to the correct name

7.Change the IP address to the correct IP address

8.Power off or reboot the system. The next time the system is booted, it will have the complete configuration with the correct IP address and system name.

System Administration

HTTP Menus

System Administration

Upgrading the Firmware

T3 Firmware

T3 Switch stores one active and one alternate boot image.

To view the current image, or to monitor the progress of an upgrade, use:

show system image

The system image can be upgraded using FTP or TFTP. Commands used are:

Using FTP: system image load ftp://username:password@ipaddress/path/t3-app.img

Using TFTP: system image load tftp://ipaddress/path/t3-app.img

Instructions to obtain and upgrade the system image are found in the release notes of each software image.

Ethernet WallPlate Firmware

The Ethernet WallPlate software image is embedded in the T3 system image. As of the T3 3.0.0 firmware release, no upgrade is required on the Ethernet WallPlates. Check the most current firmware Release Notes to see if an image upgrade will be done on the WallPlate.

At bootup, the image version is checked. If the WallPlate image requires a reload, the time to upload all 25 WallPlates is approximately 20 minutes. Interruption during the upgrade time will not damage the WallPlate. Note, however, that the Ethernet WallPlate will be unable to carry network traffic during image upgrade.

Wireless WallPlate Firmware

The Wireless WallPlate software image is stored in the file system of the T3 Switch and loaded onto the WallPlates from that location. Each Wireless WallPlate stores one active and one alternate image. The image can be upgraded in runtime, user traffic will not be affected. The total time to complete a runtime upgrade of any single WallPlate is approximately 20 minutes. If upgrading multiple WallPlates, the system will automatically stagger the start-time of each unit. Monitor the upgrade process using this command:

show remote image

The status will display a percentage of completion, and show what action is currently being done. Do not reboot the WallPlate until it is 100% complete. Since the WallPlate supports two images, an unintentional interruption will not damage the unit.

Upgrading the software on the Wireless WallPlate requires three steps:

Step 1: FTP or TFTP the Wireless WallPlate image to the file system of the T3 Switch

file copy tftp://<IP of TFTP server>/path/mc800-app.img to mc-800-app.img

NOTE: do not change the name of the file.

Step 2: Load the new image into the alternate image bank on the Wireless WallPlate

remote image load port<x> tftp://<Private IP address of T3>/mc800-app.img

NOTE: for information on IP Addressing refer to pages 24-26, ???Managing the Wireless WallPlate???

Step 3: Reboot the Wireless WallPlate to activate the new software

remote image boot port<x> alternate remote reboot port<x>

System Administration

Line Quality

T3 includes Forward Error Correction in the VDSL frames. Bit errors that are not corrected are counted and reported as a Line Quality measurement. Bit errors are averaged over 1 second of time. An SNMP trap will be sent to the SNMP trap recipient when the threshold is crossed. The line quality status will change in the webUI and the Command Line Interface. There are two thresholds that will be set:

Maximum threshold ??? the line quality status will change to Fair when the errors increase beyond the maximum threshold

Minimum threshold ??? the line quality status will change to Good when the errors decrease below the minimum threshold

To set the line quality threshold, use the following command:

interface dsl thresholds min-threshold <0.5 to 50> max-threshold <0.5 to 50>

Line quality threshold can also be set from the webUI using the Interface DSL menu

By default, the thresholds are set to:

System Administration

View System Configuration and Status

Configuration and Status can be viewed using the Show commands. To view the available show items, use the following command from the CLI:

show ?

Ex: View Current and alternate software versions on the system and the WallPlates:

show system image show system inventory show remote image show remote inventory

T3 OS displays the configuration from the CLI in three useful modes. All configuration displays can be accessed from the ???show system config??? command syntax.

System Administration

Commit mode

T3 OS supports automatic and manual commit modes. When in automatic mode, every command will be executed immediately and saved to memory. The commands will be active if the system is rebooted or power cycled.

In manual mode, commands are executed immediately, but are not saved to memory. The commands will be lost when rebooted if they are not committed.

To change the mode:

system config mode <auto|manual(mode)>

To commit manual commands to memory:

system config commit

Reset to Default Configuration

From the CLI, enter the following command:

system config default

Note: This command is only available from a local serial login session to prevent accidental default from a network login.

Other Configuration Help

The T3 Command Reference is the master text for all T3 or T3 PowerBroadband configurations. It contains an alphabetical listing of all CLI commands, syntax and example configuration.

The web UI features a context-sensitive help system.

Managing the Wireless WallPlates

Managing the Wireless WallPlates

The Wireless WallPlate is managed through two interfaces; one interface is via an embedded management channel within the VDSL frames. The other interface is through a layer 3 IP address.

WallPlate Inventory and Firmware Image

Show remote inventory

???show remote inventory??? command uses the embedded channel to read hardware rev and basic information, including serial number and BSS MAC range. Additionally, this out-of-band channel is used to detect the device and initiate communications. This interface can operate if IP addressing is invalid or the system is unable to communicate at Layer 3. This command will read hardware information for the Wireless WallPlate or the m2 Ethernet WallPlate.

Each Wireless WallPlate has 16 MACs, assigned to 16 WLANs. To read the MAC addresses assigned to the WLANs, use;

show remote inventory port<x>

Note that only one MAC address is shown for the BSS. This is the starting MAC, assigned to WLAN 1 on that radio. The remaining 15 WLANs will increment from the last octet, 00.

6 byte MAC address

00 = WLAN 1

01 = WLAN 2

02 = WLAN 3

03 = WLAN 4

04 = WLAN 5

05 = WLAN 6

06 = WLAN 7

07 = WLAN 8

08 = WLAN 9

09 = WLAN 10

0A = WLAN 11

0B = WLAN 12

0C = WLAN 13

0D = WLAN 14

0E = WLAN 15

0F = WLAN 16

Show remote image

???show remote image??? command uses the layer 3 interface to communicate. Use this command to ensure the T3 has full access to the Wireless WallPlate. Note this command will not read information from an m2 Ethernet WallPlate. If this command stalls, then the T3 cannot communicate. This is most likely an IP addressing mistake.

Managing the Wireless WallPlates

IP Addresses

Private IP address

The T3 system requires an IP address for network management. This T3 management address is assigned using the following command:

ip config ip-address <your IP> mask <your mask> gateway <your gateway>

The Wireless WallPlates also require an IP address for management by the T3 system. The IP address pool assigned to the Wireless WallPlates can be in the same subnet as the network management IP address, or it can be a private IP address space that is not used outside the T3 system.

The default configuration is to use a private IP address space to manage the Wireless WallPlates.

Note these important operational parameters when using the private IP space to manage Wireless WallPlates:

1.All T3 systems on the same property (same layer 2 network) can use the same private IP space to communicate with their own Wireless WallPlates. There will not be an IP conflict on the network.

2.The Wireless WallPlates will not send ARPs to the upstream Ethernet network.

3.The Wireless WallPlates will not send DHCP requests to the upstream Ethernet network.

4.The default private IP address space is 192.168.10.226 through 192.168.10.250. All WallPlates will be assigned an IP address starting with 192.168.10.226.

5.The default private IP internal address is 192.168.10.1. Use this address when loading new firmware to the Wireless WallPlate from the internal file system on the T3 Switch.

To enable the private IP addressing, type:

ip private enable

If you desire to set your own private ip addressing space, you must configure two commands:

Enable the private IP gateway:

Configure the private IP network:

ip private config <ip> mask <mask> ip private enable

dhcp server disable

dhcp server config network private start <ip> end <ip> dhcp server enable

NOTE: The DHCP server will not disable if any WallPlates already have an IP address. It is best to change the DHCP server config before the WallPlates link, or else you must disable the DSL ports and re-enable them after the configuration is complete.

To disable all DSL ports and remove DHCP address: interface dsl disable port(1-25)

Managing the Wireless WallPlates

Public IP address

If you wish to use 802.1x authentication, or if you wish to use ping to monitor the Wireless WallPlates, you must set the DHCP pool as a public pool. Note the following steps are required:

NOTE: The public pool must be in the same subnet as the IP address of the T3 Switch.

Static IP address pool

Static leases can be added for the public IP address pool. To use a static lease, you must know the MAC address of the radio and the IP you wish to assign. To get a list of MAC addresses, first link the Wireless WallPlates via the standard DHCP server configuration. View the list using, ???show dhcp server lease???. The list of MAC addresses can be used to create the static lease table.

The MAC address of the radio is printed on the product serial label. Also, the MAC addresses will appear in the forwarding bridge. To view the forwarding bridge table, type ???show bridge address???

Managing the Wireless WallPlates

Configuring a WLAN

Four steps are required to enable a WLAN and start broadcasting:

Step1: Create a profile to contain the SSID and per-SSID parameters

wifi wlan profile add <SSID>

ex: wifi wlan profile add My_WLAN

Step2: Bind the profile to a WLAN

wifi wlan config <wlan<1-25>-<1-16>> profile <SSID>

ex: wifi wlan config wlan(1-25)-1 profile My_WLAN

Step3: Enable the WLAN

wifi wlan enable <wlan<1-25>-<1-16>> ex: wifi wlan enable wlan(1-25)-1

Step4: Enable the Radio

interface wireless enable <radio<1-25>>

ex: interface wireless enable radio(1-25)

Global Radio Commands

Use the following commands to Configure Global radio parameters:

Managing the Wireless WallPlates

Per-WLAN Commands

Use the following commands to configure per-WLAN parameters:

Monitor the WLANs and radios

Use the following commands to monitor the configuration and operational status of the WLANs:

Expanded Statistics and Status

Most ???show??? commands display high level, important information for quick review. To see more detailed status or statistics, specify the actual radio or WLAN. For example;

Managing the Wireless WallPlates

Access Control Lists (ACLs)

Configure layer 3 ACLs based on an administrator defined IP addresses and pre-defined services. The pre- defined services are HTTP, FTP, Telnet, SNMP.

ACLs are processed from index 1 through index 20. If no matches are found, the access is granted.

Place the most restrictive access rules on the lower index number.

To enter ACLs from the CLI, use the following command:

ip access-list config <1-20(index)> <deny|permit(type)> [ip-address #.#.#.#] [mask #.#.#.#] [service all|ftp|telnet|http|snmp]

Ex: To block all HTTP access from any device, enter:

ip access-list config 1 deny http

Ex: To block all network access from all devices except Telnet from a specific subnet, enter:

ip access-list config 1 permit ip-address 64.174.72.129 mask 255.255.255.128 service telnet ip access-list config 10 deny service all

Note: A 32-bit subnet mask will specify one single device with the specified IP address

RADIUS network authenticated login

RADIUS network authenticated login

RADIUS server configurations apply to administrative access accounts and client 802.1X authentication. RADIUS access-requests are supported, but RADIUS accounting messages are not. Up to five RADIUS servers can be added. The default RADIUS port 1812 is used and is not configurable.

Authenticating Administrative Access

RADIUS network authenticated logins allows the administrators to easily change all passwords by changing the password on the RADIUS server, simplifying management of a large network with multiple users.

To use RADIUS network authentication, you will need a properly configured RADIUS server (free RADIUS servers are available for Linux operating systems or fee-based server products are available on UNIX and Microsoft NOS).

RADIUS authenticated logins only support the ???admin??? user account privileges with the following exceptions:

???The RADIUS account cannot disable RADIUS login support

???The RADIUS account cannot change the built-in ???Admin??? password

Note: The ???admin??? account name is not reserved. You may create an ???admin??? account on the RADIUS server. If so, the T3 will first check the password against the local ???admin??? account password before trying the RADIUS server. Unless there is a special reason to do so, we recommend not using an ???admin??? account on the RADIUS server

Authenticating Clients using 802.1X

To use RADIUS authentication, the server must support 802.1X protocol and a supported EAP type. Supported EAP types are TLS, TTLS, and PEAPv0 (also known simply as PEAP)

Configure the RADIUS Server

To create a RADIUS server configuration from the CLI, use the following command:

radius server config <1-5(index)> <ip-address #.#.#.#> <shared-secret string> <timeout 1-10> <retries 1-120>

RADIUS network authenticated login

WallPlate Installation

Basic Configuration

The following commands will enable a basic network configuration. The T3 system will ignore the text following the ???#??? comment character.

NOTE: Telnet is recommended due to the TCP flow control. Ranged commands can take several seconds to execute. If the console is used to paste a long string of commands, set a Line Delay of 500ms on your serial program so that the serial buffer does not overflow. If this happens, some commands may be lost or not executed.

Login using the serial console or telnet to the default IP address.

#BASIC IP AND SYSTEM CONFIGURATION

####################################

dhcp server enable

ip config ip <your IP address> mask <your mask> gateway <your gateway> ip private enable

vlan enable

vlan mode local port remote tag system reboot

#ENABLE AND CONFIGURE ONE WLAN

##################################

wifi wlan profile add <your SSID>

wifi wlan config wlan(1-25)-1 profile <your SSID> wifi wlan enable wlan(1-25)-1

#ENABLE AND CONFIGURE DSL PORTS AND REMOTE ETHERNET PORTS

################################################################

interface dsl config port(1-25) max-down 10 max-up 10 interface remote enable port(1-25)-(1-2)

#ENABLE THE LINE POWER AND RADIO

##################################

interface wireless enable radio(1-25) interface dsl po en port(1-25)

#REBOOT

########

system reboot

Tools Required:

Number 2 Philips head screwdriver

Note: if using a power drill, set the torque clutch to 5 in-lbs.

Components provided with the MC-802 WallPlate:

1 ??? MC-802 WallPlate

1 ??? RJ11 wall jack mounting adapter

1 ??? 100mm (4???) RJ11 pigtail cable

2 ??? 6-32 thread forming Philips head screws, 0.375???

RADIUS network authenticated login

Components required to purchase:

Regulated 12V power supply. Use of the wrong power supply could result in damage to your WallPlate unit. Please order a small quantity of regulated 12V power supplies from Motorola to use during installation.

If you do not have the correct regulated 12V power supply ??? STOP. Order a regulated 12V power supply from your Motorola PBN sales representative.

Step 1

1.Loosen screws on wall plate approximately 6mm (1/4???)

2.Attach the bracket using the keyhole slots

3.Tighten screws until the bracket is firmly attached, do not over tighten

RADIUS network authenticated login

Step 2

Connect 50mm (2???) cable (supplied) between bottom mounted RJ11 port on the MC-802 and the existing RJ11 jack.

Step 3

Attach the MC-802 to the Mounting Adapter using the supplied 6/32 thread forming screws

6/32 thread forming screws

6/32 thread forming screws

Step 4

1.Connect the local AC power adapter to the WallPlate

2.Connect the analog phone to the RJ11 phone jack

Step 5

After WallPlate Link LED is solid, verify the device is connected using the command, ???show int dsl status???. It is best to have a technician in the phone room directly connected to the T3 Switch to coordinate and enable Line Power.

Enable line power

Determine which port is being installed

RADIUS network authenticated login

show bridge address

The MAC address of the PC will appear along with the connected line.

Enable line power

From the CLI, enter this command:

interface dsl power enable portx (enable only the port being installing)

Finish the installation

Remove the 12V regulated power supply. If the correct port is enabled for line power, the WallPlate will reset and operate from in-line power.

RADIUS network authenticated login

802.1Q VLANs

Note: The system requires a reboot after the ???vlan enable??? command. If the system is not rebooted, the webUI will not display the VLAN configuration and the CLI will not execute VLAN commands.

VLAN Specification

VLAN terminology

The T3 Switch is a VLAN switch. The WallPlate is also a VLAN switch. Therefore, be certain that packets traversing the DSL links between the T3 Switch and the WallPlate are always TAGGED.

RADIUS network authenticated login

Tag-based VLAN Mode Tag based mode is fully 802.1Q VLAN compliant. You must explicitly configure the Egress and Ingress rules for each port and each VLAN. On the webUI, use the 802.1Q TAG-BASED VLAN menu to configure VLANs.

The T3 Switch and WallPlate can operate independently. Be sure to configure all ports on the Switch and the WallPlates for proper operation.

Port-based VLAN Mode Port based VLAN is also called Port Isolation or Port Privacy in other switches.

When operating in port-based mode, the T3 Switch will ignore 802.1Q VLAN tags. Port isolation is based on a VLAN Map. On the webUI, use the PORT-BASED menu to see the VLAN Map and change the mapping. See below for more details.

Note: The Switch operates in port-based or tag-based mode; whereas the WallPlates only operate in tag-based, or disabled. This allows for special case configurations where the WallPlates do all the 802.1Q VLAN tagging, while the Switch maintains port- to-port privacy.

VLAN commands

All VLAN configurations are also available from the webUI.

RADIUS network authenticated login

show vlan membership Displays the memberships in Rows and Columns

Web UI configuration

VLANs can be configured from the CLI, web UI or SNMP. The CLI advantage is support for scripting the entire configuration. The CLI disadvantage is the large number of commands required to execute the complete configuration.

The web UI is slower since it relies on Javascript running on your local PC, and the overhead associated with transmitting the configuration data. The graphical display is easy to follow and should be used to get familiar with the system.

Vlan General webUI

VLAN Config

Enable VLAN support. Requires system reboot.

VLAN Mode

Local Mode refers to the T3 Switch. Port-based or Tag-based is supported. Remote Mode refers to the WallPlate. Tag-based or disabled is supported.

VLAN Special Interfaces

If video is delivered on a defined ???video VLAN???, be sure to assign IGMP to the VLAN used for video. When IGMP Proxy is enabled, T3 will proxy IGMP packets with the VLAN ID of the group in this configuration.

Management packets can be tagged with a specific VLAN ID for layer 2 security. Enable management VLANs and assign a VLAN ID.

The VLAN must first be created using the 802.1Q

Tag Based menu.

VLAN Multicast

Enable multicast support and assign the VLAN where multicast packets will be sent. This VLAN should be the same as the IGMP VLAN ID for proper delivery of video.

RADIUS network authenticated login

Tag-based VLAN webUI

Create/Delete VLANs

Use this menu to create new VLANs and assign a name to the VLAN. Note that you cannot delete VLAN 1, however VLAN 1 can be removed from all interfaces.

Set VLAN Egress Rules

Set the VLAN membership rules.

Click 3 times in the box to select (U)ntagged, (T)agged or not a member. In this example, Eth1 is a (T)agged member of VLAN 50.

DSL ports will always be a (T)agged member of any VLANs on the connected WallPlate

In this example, Port 1 of the first WallPlate is an (U)ntagged member of VLAN 50.

Set VLAN Ingress Rules

Set the PVID for each port. This is also known as the native VLAN for the port. All packets received on these ports (as from a PC connected to the port) are assigned the PVID of the port

Port-based VLAN webUI

When the local mode is set to Port-based (The T3 Switch is the local mode), use the Port-based menu to create a Port Map.

By default, Eth1 and Eth2 can communicate with each other. All DSL ports can communicate with Eth1 and Eth2, but NOT with each other.

The example at right shows an effective way to configure port privacy on all DSL ports, and configure Eth2 as a cascade port. This example can be replicated on all Switches in a cascade for simple, effective port privacy.

Note:

???Eth1 can communicate with Eth2

???Eth1 can communicate with all DSL ports

???Eth2 cannot communicate with all DSL ports

???DSL ports cannot communicate with each other

RADIUS network authenticated login

Port-based VLAN webUI, continued

In the example at right, Note:

???Eth1 and Eth2 cannot communicate together

???Eth1 can communicate with DSL ports 1 ??? 12

???Eth2 can communicate with DSL ports 12 ??? 25

???Port 12 can communicate with both Eth1 and Eth2

???Ports 6 and 12 can also communicate together

Note that DSL ports can only talk to the upstream Eth1 or Eth2. The only exception is DSL ports 6 and 12.

Port-based mode on the T3 Switch can be mixed with Tag-based mode on the WallPlate for an effective method to configure VLANs for advanced services.

Note VLAN Tutorial One for an example of mixing

Port-based and Tag-based VLANs.

Quality of Service

Quality of Service (QoS)

QoS commands and concepts

network qos [enable | disable]

Enable qos support. To disable qos, use network qos disable

network qos interface priority <interface-id> mode <mode> [level <level>]

Sets the packet classifier mode for the port receiving packets.

Where;

Mode is dynamic or static. Dynamic classifier will read the IP TOS or 802.1P precedence bit of the incoming packet. Static classifier assigns all packets received on the port to one of the four queues

Level is the default queue for packets received on the port. When the mode is dynamic, then level is assigned to packets that do not match the classifier. When the mode is set to static, then level applies to all packets received on the port.

The four queues are critical, high, medium, and low.

network qos classification <method>

where method is either 802.1p or tos

Quality of Service

Once a port has been set to use dynamic or static mode; specify whether T3 will use IP TOS or 802.1P precedence bit for dynamic packet classification.

network qos interface queue <interface-id> mode <mode>

Deprecated commands to set the queuing mechanism on a port. This command is superseded by network qos interface egress which has more configuration options.

When using this command, note that WFQ has a fixed percentage for each queue:

In priority mode, strict priority applies to all queues where a higher queue always transmits before a lower queue.

Note that when using wfq mode, a low priority queue will use all the available bandwidth if a higher priority queue is not in the transmission buffer.

network qos interface egress priority <interface-id> queue <queue>

Any queue assigned as a Priority queue will transmit using strict priority. A higher level queue will always transmit before a lower level queue. Use priority mode for latency and jitter sensitive applications.

network qos interface egress shaping <interface-id> queue <queue> peak <peak rate> average <avg rate> burst <burst size>

Set a fixed traffic shaping parameter for each queue. Note that a queue will never exceed the peak rate parameter regardless of other services on the port.

network qos interface egress wfq <interface-id> queue <queue> weight <0-200>

Configure the behavior of the WFQ scheduling method. Bitrates are determined as a percentage of the total queue weights.

In order to determine the percentage of bandwidth that will be allocated for a particular queue, divide the queue weight by the sum of all the queues ???weight???.

For example; assume the High queue weight is 100 and the Medium queue weight is 50. 100 + 50 = 150. So, the High queue will receive 66% of the bandwidth (100/150=0.667) and the Medium queue will receive 33% of the bandwidth (50/150=0.33).

network qos multicast config queue-allocation <allocation>

Multicast packets are allocated a separate set of transmission buffers. Set the multicast queue to be the same queue where the multicast packets will be transmitted. For example, if using video packets with an IP TOS bit, assign the packets to the high queue based on the IP TOS bit, and assign the multicast queue to be also use high. T3 has no way to automatically determine where the multicast packets will be transmitted.

network qos wred enable | disable

Quality of Service

Enable or disable WRED support. WRED adds further protection for data integrity in a contention based Ethernet network by randomly discarding TCP packets according to administrator settable parameters for thresholds.

network qos wred config min-discard <min-discard> max-discard <max-discard>

Set the rate at which Ethernet frames will be discarded once the rate exceeds the thresholds. Note that two discard rates are supported. Min-discard is the rate that frames are discarded when they reach the minimum configured threshold. Max-discard is the rate that frames are discarded when they reach the maximum configured threshold. Often, the max-discard rate will be set to 100.

network qos interface wred <eth<1-2>|port<1-25>(interface-id)> <queue low|medium|high|critical> <min-threshold 1- 100> <max-threshold 1-100>

Set the minimum and maximum buffer threshold for each queue, on each port. Once either threshold is crossed, frames are discarded at the discard rates specified by the network qos wred config command.

Dynamic packet classification

In dynamic mode, packets are classified by the 802.1P Ethernet precedence bit or IP TOS (precedence bits) in the Diffserv byte. This definition is taken from the latest RFC 2475. Note that the IP TOS bits are defined as the three most significant bits of the DiffServ byte.

Ethernet frames are mapped to transmission queues based on the following chart:

QoS Example

QoS Example

An easy way to demonstrate QoS is to use the traffic shaping queue scheduler. To further simplify the example, dynamic packet classifier is not used.

Packet Classification:

Static. All packets on Eth1 will be classified high. All packets on Eth2 will be classified low.

Packet transmission:

Shaping. All four queues will be configured with unique bitrates.

Connections:

A SmartBits network tester can be used; however the same QoS results can be easily demonstrated using iperf and four PCs. In either case, one flow will be connected from Eth1 of the T3 Switch to Port1-1 of the first WallPlate. The other flow will be connected to Eth2 of the T3 Switch and Port1-2 of the first WallPlate.

Commands:

network qos enable system reboot

network qos interface priority eth1 mode static level high network qos interface priority eth2 mode static level medium

network qos interface egress shaping port1 queue critical peak 30 average 30 burst 100 network qos interface egress shaping port1 queue high peak 20 average 20 burst 100 network qos interface egress shaping port1 queue med peak 10 average 10 burst 100 network qos interface egress shaping port1 queue low peak 5 average 5 burst 1

Note that the PCs connected to Eth1/Port1-1 will receive 20Mbps bitrate; whereas the other PCs will receive 10Mbps bitrate. While the test is running, change the static level command and watch the behavior change.

network qos interface priority eth1 mode static level low

Line Status

Line Status

Operators can view extensive details about DSL line characteristics from the CLI, Port Monitor web page, or SNMP.

To view line characteristics using the webUI, click on DSL Monitor, then click the + sign to expand the port you wish to view.

Using the Port Monitor web page, the operator can quickly scan the status of all ports in the system. A color coded grid indicates the important status of each port e.g. GREEN indicates the Ethernet port is connected, whereas GREY indicates the port is enabled, but disconnected.

Per line details visible: