Installation Manual
JY997D02201G
This manual contains text, diagrams and explanations which will guide the reader in the correct installation, safe use and operation of the
Specifications are subject to change without notice
Guidelines for the Safety of the User and Protection of the
This manual has been written to be used by trained and competent personnel. The definition of such a person or persons is as follows:
a)Any engineer using the product associated with this manual, should be of a competent nature, trained and qualified to the local and national standards. These engineers should be fully aware of all aspects of safety with regards to automated equipment.
b)Any commissioning or service engineer must be of a competent nature, trained and qualified to the local and national standards.
c)All operators of the completed equipment (see note) should be trained to use that product in a safe manner in compliance to established safety practices.
Note: The term ???completed equipment??? refers to a third party constructed device which contains or uses the product associated with this manual.
Note???s on the Symbols Used in this Manual
At various times through out this manual certain symbols will be used to highlight points of information which are intended to ensure the users personal safety and protect the integrity of equipment.
1)Indicates that the identified danger WILL cause physical and property damage.
2)Indicates that the identified danger could POSSIBLY cause physical and property damage.
???Under no circumstances will Mitsubishi Electric be liable or responsible for any consequential damage that may arise as a result of the installation or use of this equipment.
???All examples and diagrams shown in this manual are intended only as an aid to understanding the text, not to guarantee operation. Mitsubishi Electric will accept no responsibility for actual use of the product based on these illustrative examples.
???Please contact a Mitsubishi Electric distributor for more information concerning applications in life critical situations or high reliability.
Associated Manuals
~Necessary manual
|Either manual is necessary.
Refer to the manual of the connected programmable controller for further details concerning that unit.
1. Introduction
1)The
2)Various devices can be monitored and PLC data changed through the screens in the GOT.
3)Using PLC programming software, FX Series PLC user programming can be uploaded, downloaded and monitored via the GOT.
4)The
5)The
The
PLC
Programming port
GOT
For further details concerning applicable PLCs and connections to the PLC, refer to the
1.1 Product Lists
GOT Main Unit
???In addition to the connections shown above, the
For further details concerning connectable equipment and communication cables, refer to the
Optional screen creation software
Caution
During abnormal communication (including cable breakage) when monitoring within the GOT, communication between the GOT and programmable controller CPU is interrupted and it is impossible to operate keys or devices in the PLC via the GOT.
Communication and operation resumes when the GOT system is correctly configured.
DO NOT configure the emergency stop or safety features through the GOT, and be sure that there will be no adverse consequences in the event of a GOT - PLC communications malfunction.
Note
???Do not lay signal cables near high voltage power cables or allow them to share the same trunking duct. Otherwise effects of noise or surge induction are likely to occur. Keep a safe distance of more than 100 mm away from these wires.
???Operate switches on the panel by hand.
DO NOT use excessive force, or attempt to operate them with hard or pointed objects. The tip of a screw driver, pen or similar objects for example may break the screen.
Connectable PLC units differ for the
1.2Dimensions and Each Part Name [Both
1)Front panel
2)Rear panel
e)Mounting bracket and tightening bolt (accessory)
f)Power terminals (Not provided for the
g)Communication ports
COM0
COM1
h)Communication cable (optional)
i)Packing seal (accessory)
2.3 Screen Hardware Specifications
???Bright dots (always lit) and dark dots (unlit) may appear on a liquid crystal display panel. It is impossible to completely avoid this symptom, as the liquid crystal display comprises of a great number of display elements.
Flickers may be observed depending on the display color.
Please note that these dots appear due to its characteristic and are not caused by product defect.
???When the same screen is displayed for a long time, an incidental color or partial discoloration is generated on the screen due to heat damage, and it may not disappear.
3. Installation
Note
???Do not mount the GOT in an environment that contains dust, corrosive soot, conducive dust, corrosive
or flammable gas, or expose the unit to high temperatures, dew condensation, direct sunlight, rain and wind or impact and vibration.
If the GOT is used in such a place, electrical shock, fire, malfunction, damages or deterioration may occur.
???Never drop cutting chips or electric wire chips into the ventilation window of the GOT when drilling screw holes or performing wiring. Such chips may cause fire, failure or malfunction.
???Make sure that the power is turned off, before securely connecting any cables. Poor connection may cause malfunction.
The GOT is designed to be mounted in a panel. Install it using the following procedure:
The installation method and the dimensions required inside the panel are identical for the
Illustrations of the
1)Preparing the panel surface. (See Figure A)
On the panel surface, cut a rectangular mounting slot with the dimensions shown below.
A space of 10 mm is required for the right and left sides of the slot and inside the panel for metal fixtures as shown in ???5) Inner panel installation dimensions???.
Note
Make sure that the thickness of the panel surface is no more than 5 mm (0.20").
2)Inserting the GOT into the panel surface (See Figure B)
Attach the packing seal to the GOT, and insert the GOT from the front face of the panel surface.
a)Packing seal
b)GOT
c)Mounting slot
3)Fixing the GOT (See Figure C)
Attach the hooks of the mounting brackets (supplied) in to the mounting holes of the GOT. Tighten mounting bolts (also supplied) until the GOT is securely fixed.
Fix mounting bolts in all four positions, right and left of the GOT.
a)Clamping bolt
b)Mounting bracket
Note
Tighten the clamping bolts with a torque of 0.18 to 0.22 N??m.
4)Peeling of the protective sheet
Peel off the protective sheet on the surface of the product before use.
5)Inner panel installation dimensions (See figure D).
When installing the GOT, make sure the inner dimensions shown below are available.
a)PLC connection cable
b)Packing seal
4. Power Supply Wiring
Cautions
???Cut OFF all external phases of the power supply before installation or wiring to avoid electric shock or serious damage to the product.
Note
???Wire the DC power supply to the dedicated terminals as described in this manual. Wiring an AC power supply will cause serious damage to the product.
???Attach a 2A fuse to the 24V DC power supply. Correctly connect the + and - terminals of the DC power supply as descried in this manual.
Reverse connection of the power supply may cause failure.
???Perform grounding (resistance: 100??? or less) with an electric wire of 1.25 mm2 or more to the ground terminal of the GOT.
Never perform common grounding of the GOT and a strong power system.
The power for the
The power of the GOT is supplied from the PLC or an external power supply.
???Connection example
1)When supplying the power from the FX Series PLC
Connect the power terminals provided on the rear face of the GOT to the 24V DC service power supply of the PLC base or extension unit.
2)When supplying the power from an external power supply
Connect the power terminals provided on the rear face of the GOT to the 24V DC terminals of the external power supply.
Grounding resistance 100??? or less
External
power
Grounding supply 2A resistance
100??? or less
When wiring 2 wires per terminal
Terminal
Cautions on connection
The current consumption of the GOT is 80mA/24V DC (while the backlight is ON). When supplying power from the 24V DC service power supply of the FX Series PLC main unit or extension unit, consider the capacity of the service power supply of the base or extension unit and the total current supplied to proximity switches, extension blocks and special blocks. If the total current including the power supplied to the GOT exceeds the capacity of the service power supply, supply the power to the GOT from the external power supply.
???Even if instantaneous power interruption of less than 5 ms occurs, the GOT continues to operate. When power interruption for a considerable period of time or voltage drop occurs, the GOT stops its operation. However, when the power supply is recovered, the GOT automatically restarts its operation. (The screen displayed just after recovery is determined by the working environment originally set.)
???When wiring the power supply, use electric wires of 0.75 mm2 or more to avoid voltage drop. Use
5. Maintenance
Cautions
Never disassemble or modify the GOT. Disassembly or modification may cause failure, malfunction or fire. For repair, please, contact a service representative.
Note
Make sure to turn OFF the power, before connecting/disconnecting cables.
If you connect/disconnect cables while the power is turned on, failure or malfunction may be caused.
A backlight lithium battery is not supplied with the GOT. The Liquid Crystal Display has a service life of approximately 50,000 hours.
When repairing the Liquid Crystal Display, please, contact a service representative.
Notification of CE marking
The following products have shown compliance through direct testing (to the identified standards) and design analysis (forming a technical construction file) to the European Directive for Electromagnetic Compatibility (2004/108/EC) when used as directed by the appropriate documentation.
???This product is designed for use in industrial applications.
???Manufactured by: Mitsubishi Electric Corporation
???Manufactured at: Mitsubishi Electric Corporation Himeji Works
840
???Authorized Representative in the European Community: Mitsubishi Electric Europe B.V.
Gothaer Str. 8, 40880 Ratingen, Germany
For more details please contact the local Mitsubishi Electric sales site.
Notes Regarding the Use of GOT Units
General notes on the use of Communication Cables
Any device which utilizes a data communication function is susceptible to the wider effects of local EMC noise. Therefore, when installing any communication cables care should always be taken with the routing and location of those cables. The GOT units identified on the previous page are compliant with the EMC requirement when the following communication cables are used:
When using the
Ex. 1
E = Additional earth strap connected to the cables shield. Free end of the earth strap must be connected to an earth point.
F = Ferrite core
Ex. Tokin -
Warranty
Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi; opportunity loss or lost profits caused by faults in the Mitsubishi products; damage, secondary damage, accident compensation caused by special factors unpredictable by Mitsubishi; damages to products other than Mitsubishi products; and to other duties.
For the detailed warranty, refer to the
Manual number : JY997D02201
Manual revision : G
HEAD OFFICE : TOKYO BUILDING,
HIMEJI WORKS : 840, CHIYODA CHO, HIMEJI, JAPAN
1. Introduction
1.2Dimensions and Each Part Name [Both
Installation Manual
JY997D02201G
This manual contains text, diagrams and explanations which will guide the reader in the correct installation, safe use and operation of the
1)The
2)Various devices can be monitored and PLC data changed through the screens in the GOT.
3)Using PLC programming software, FX Series PLC user programming can be uploaded, downloaded and monitored via the GOT.
4)The
5)The
The
PLC
Programming port
GOT
Specifications are subject to change without notice
Guidelines for the Safety of the User and Protection of the
This manual has been written to be used by trained and competent personnel. The definition of such a person or persons is as follows:
a)Any engineer using the product associated with this manual, should be of a competent nature, trained and qualified to the local and national standards. These engineers should be fully aware of all aspects of safety with regards to automated equipment.
b)Any commissioning or service engineer must be of a competent nature, trained and qualified to the local and national standards.
c)All operators of the completed equipment (see note) should be trained to use that product in a safe manner in compliance to established safety practices.
Note: The term ???completed equipment??? refers to a third party constructed device which contains or uses the product associated with this manual.
Note???s on the Symbols Used in this Manual
At various times through out this manual certain symbols will be used to highlight points of information which are intended to ensure the users personal safety and protect the integrity of equipment.
1)Indicates that the identified danger WILL cause physical and property damage.
2)Indicates that the identified danger could POSSIBLY cause physical and property damage.
???Under no circumstances will Mitsubishi Electric be liable or responsible for any consequential damage that may arise as a result of the installation or use of this equipment.
???All examples and diagrams shown in this manual are intended only as an aid to understanding the text, not to guarantee operation. Mitsubishi Electric will accept no responsibility for actual use of the product based on these illustrative examples.
???Please contact a Mitsubishi Electric distributor for more information concerning applications in life critical situations or high reliability.
Associated Manuals
~Necessary manual
|Either manual is necessary.
Refer to the manual of the connected programmable controller for further details concerning that unit.
For further details concerning applicable PLCs and connections to the PLC, refer to the
1.1 Product Lists
GOT Main Unit
???In addition to the connections shown above, the
For further details concerning connectable equipment and communication cables, refer to the
Optional screen creation software
Caution
During abnormal communication (including cable breakage) when monitoring within the GOT, communication between the GOT and programmable controller CPU is interrupted and it is impossible to operate keys or devices in the PLC via the GOT.
Communication and operation resumes when the GOT system is correctly configured.
DO NOT configure the emergency stop or safety features through the GOT, and be sure that there will be no adverse consequences in the event of a GOT - PLC communications malfunction.
Note
???Do not lay signal cables near high voltage power cables or allow them to share the same trunking duct. Otherwise effects of noise or surge induction are likely to occur. Keep a safe distance of more than 100 mm away from these wires.
???Operate switches on the panel by hand.
DO NOT use excessive force, or attempt to operate them with hard or pointed objects. The tip of a screw driver, pen or similar objects for example may break the screen.
Connectable PLC units differ for the
Further information can be found in
1)Front panel
2)Rear panel
e)Mounting bracket and tightening bolt (accessory)
f)Power terminals (Not provided for the
g)Communication ports
COM0
COM1
h)Communication cable (optional)
i)Packing seal (accessory)
2.3 Screen Hardware Specifications
???Bright dots (always lit) and dark dots (unlit) may appear on a liquid crystal display panel. It is impossible to completely avoid this symptom, as the liquid crystal display comprises of a great number of display elements.
Flickers may be observed depending on the display color.
Please note that these dots appear due to its characteristic and are not caused by product defect.
???When the same screen is displayed for a long time, an incidental color or partial discoloration is generated on the screen due to heat damage, and it may not disappear.
3. Installation
Note
???Do not mount the GOT in an environment that contains dust, corrosive soot, conducive dust, corrosive
or flammable gas, or expose the unit to high temperatures, dew condensation, direct sunlight, rain and wind or impact and vibration.
If the GOT is used in such a place, electrical shock, fire, malfunction, damages or deterioration may occur.
???Never drop cutting chips or electric wire chips into the ventilation window of the GOT when drilling screw holes or performing wiring. Such chips may cause fire, failure or malfunction.
???Make sure that the power is turned off, before securely connecting any cables. Poor connection may cause malfunction.
The GOT is designed to be mounted in a panel. Install it using the following procedure:
The installation method and the dimensions required inside the panel are identical for the
Illustrations of the
1)Preparing the panel surface. (See Figure A)
On the panel surface, cut a rectangular mounting slot with the dimensions shown below.
A space of 10 mm is required for the right and left sides of the slot and inside the panel for metal fixtures as shown in ???5) Inner panel installation dimensions???.
Note
Make sure that the thickness of the panel surface is no more than 5 mm (0.20").
2)Inserting the GOT into the panel surface (See Figure B)
Attach the packing seal to the GOT, and insert the GOT from the front face of the panel surface.
a)Packing seal
b)GOT
c)Mounting slot
3)Fixing the GOT (See Figure C)
Attach the hooks of the mounting brackets (supplied) in to the mounting holes of the GOT. Tighten mounting bolts (also supplied) until the GOT is securely fixed.
Fix mounting bolts in all four positions, right and left of the GOT.
a)Clamping bolt
b)Mounting bracket
Note
Tighten the clamping bolts with a torque of 0.18 to 0.22 N??m.
4)Peeling of the protective sheet
Peel off the protective sheet on the surface of the product before use.
5)Inner panel installation dimensions (See figure D).
When installing the GOT, make sure the inner dimensions shown below are available.
a)PLC connection cable
b)Packing seal
4. Power Supply Wiring
Cautions
???Cut OFF all external phases of the power supply before installation or wiring to avoid electric shock or serious damage to the product.
Note
???Wire the DC power supply to the dedicated terminals as described in this manual. Wiring an AC power supply will cause serious damage to the product.
???Attach a 2A fuse to the 24V DC power supply. Correctly connect the + and - terminals of the DC power supply as descried in this manual.
Reverse connection of the power supply may cause failure.
???Perform grounding (resistance: 100??? or less) with an electric wire of 1.25 mm2 or more to the ground terminal of the GOT.
Never perform common grounding of the GOT and a strong power system.
The power for the
The power of the GOT is supplied from the PLC or an external power supply.
???Connection example
Cautions on connection
The current consumption of the GOT is 80mA/24V DC (while the backlight is ON). When supplying power from the 24V DC service power supply of the FX Series PLC main unit or extension unit, consider the capacity of the service power supply of the base or extension unit and the total current supplied to proximity switches, extension blocks and special blocks. If the total current including the power supplied to the GOT exceeds the capacity of the service power supply, supply the power to the GOT from the external power supply.
Notification of CE marking
The following products have shown compliance through direct testing (to the identified standards) and design analysis (forming a technical construction file) to the European Directive for Electromagnetic Compatibility (2004/108/EC) when used as directed by the appropriate documentation.
???This product is designed for use in industrial applications.
???Manufactured by: Mitsubishi Electric Corporation
???Manufactured at: Mitsubishi Electric Corporation Himeji Works
840
???Authorized Representative in the European Community: Mitsubishi Electric Europe B.V.
Gothaer Str. 8, 40880 Ratingen, Germany
For more details please contact the local Mitsubishi Electric sales site.
Notes Regarding the Use of GOT Units
General notes on the use of Communication Cables
Any device which utilizes a data communication function is susceptible to the wider effects of local EMC noise. Therefore, when installing any communication cables care should always be taken with the routing and location of those cables. The GOT units identified on the previous page are compliant with the EMC requirement when the following communication cables are used:
When using the
Ex. 1
E = Additional earth strap connected to the cables shield. Free end of the earth strap must be connected to an earth point.
F = Ferrite core
Ex. Tokin -
Warranty
5. Maintenance
Cautions
Never disassemble or modify the GOT. Disassembly or modification may cause failure, malfunction or fire. For repair, please, contact a service representative.
Note
Make sure to turn OFF the power, before connecting/disconnecting cables.
If you connect/disconnect cables while the power is turned on, failure or malfunction may be caused.
A backlight lithium battery is not supplied with the GOT. The Liquid Crystal Display has a service life of approximately 50,000 hours.
When repairing the Liquid Crystal Display, please, contact a service representative.
Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi; opportunity loss or lost profits caused by faults in the Mitsubishi products; damage, secondary damage, accident compensation caused by special factors unpredictable by Mitsubishi; damages to products other than Mitsubishi products; and to other duties.
For the detailed warranty, refer to the
Manual number : JY997D02201
Manual revision : G
HEAD OFFICE : TOKYO BUILDING,
HIMEJI WORKS : 840, CHIYODA CHO, HIMEJI, JAPAN