?? 30" and 36" Traditional Series Vented and Non- Vented

Range Hoods

PRODUCT MODEL NUMBERS

KHTU160K

KHTU100K

Electrical: 120-volt, 60-Hz, AC-only, 15-amp. electrical supply. Use copper wire only. A time- delay fuse or circuit breaker and separate circuit is recommended.

OVERALL DIMENSIONS

Note: Underside of hood must be a minimum of 24" (61 cm) from cooking surface.

Roof-vented model shown.

VENTING REQUIREMENTS

Recommended vent system length

3-1/4" x 10"

(8.3 cm x 25 cm) vent through the roof

Roof venting

3-1/4" x 10"

(8.3 cm x 25 cm) vent through the wall

Use 3 1/4" x 10" (8.3 cm x 25 cm) vent with maximum length of 26 feet (8 m) for vent system. For best performance, use no more than three 90?? elbows. To calculate the length of system you need, add the equivalent feet (meters) for each vent piece used in the system. See the following example.

wall

cap3-1/4" x 10" (8.3 cm x 25 cm) vent system

Recommended standard fittings

Wall venting

3-1/4" x 10"

(8.3 cm x 25 cm) 90?? elbow

= 5 ft. (1.5 m)

3-1/4" x 10"

(8.3 cm x 25 cm) flat elbow

= 12 ft. (3.7 m)

3-1/4" x 10"

(8.3 cm x 25 cm) wall cap

= 0 ft. (0 m)

Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.