?? Ice Maker

PRODUCT MODEL NUMBERS

KUIA18NNJ KUIS18NNJ

KUIA18PNL KUIS18PNJ

KUIV18NNM

Electrical: 115-volt, 60-Hz, AC-only, 15-ampere grounded circuit is required. A time-delay fuse or circuit breaker and separate circuit is recommended.

Water: A cold water supply using 1/4 in. O.D. soft copper tubing with shutoff valve.

Drain: Either a gravity-drain system or condensate pump to carry water to an existing drain.

CABINET OPENING DIMENSIONS

A. Recommended location for electrical and plumbing fixtures.

B. Floor level

B

24" (60.1 cm)

18" (45.7 cm)

DRAIN REQUIREMENTS

1?????????"

(1.9 cm)

20" (50.80 cm)

Drain lines must have a minimum of 5???8 in. (15.88 mm) inside diameter.

Drain lines must have a 1 in. drop per 48 in. (2.54 cm drop per 122 cm) of run or 1???4 in. drop per 12 in. (6.35 mm per 30.48 cm) and must not have low points where water can settle.

The ideal installation has a 1-1???2 in. (3.81 cm) standpipe installed directly below the outlet of the drain tube as shown.

You must maintain a 1 in. (2.54 cm) air gap between the drain pump hose and the standpipe.

DD. Center of drain should be 20 in. (50.80 cm) from front of door.