MOUNTING

???E6 (side mount) and V6 (flange mount): #6 screws (#8 available on certain listings). E6 enclosures meet NEMA 1; V6 enclosures meet NEMA 1 and 3*.

???BZG/H; #10 screws. Enclosures meet NEMA 1, 3*, 4*, 13*.

???Side and bottom mounting available. Side mount from either side.

1.Mount switches on flat, rigid surface.

2.Sealed, side mounted: Use sealing washers under screw heads on one side; between switch and mounting surface on other side.

3.Unsealed, side mounted: Use lockwashers under screw heads on one side; under nut on other side.

4.Connect conduit to complete seal.

*Except Q plungers.

REPLACEMENT PARTS

WIRING

Connect grounding screw or lug.

Solderless connections:

1.Use only insulated connectors.

2.Position connectors to provide as much spacing as possible.

NOTICE

1.Do not drill or machine housing.

2.Do not lubricate any internal part of switch.

3.Do not allow internal conduit condensation to drain into switch.

4.Do not enlarge mounting holes.

CONDUIT SEALING PACKETS

Basic switch: order according to catalog listing on basic switch being replaced. Replacement packet includes basic switch, mounting hardware, seal boot and bands where required.

Actuators or Accessories

LIQUID TIGHT CONDUIT FITTING

6PA187-E6 ACTUATOR PACKET

MICRO SWITCH Sensing and Control

N18 TYPES

If actuator or basic switch is replaced, the actuator may need adjustment to duplicate original switch operating point. To adjust operating point, remove lower seal band from base of seal boot. ???Peel back??? seal boot to expose bushing. With basic switch unoperated, slowly turn bushing clockwise until basic switch operates. Do not turn further after operating click is heard. Turn bushing back 1/2 turn. Tighten jam nut on bushing.

ACTUATOR DESCRIPTION

???Q???: unsealed. ???N???: seal boot around plunger. Horizontal and vertical lever adjustment.

???N80 & Q8: Roller plunger actuated.

???N81 & Q81: Cross roller plungers

???N2 & Q2: Roller lever for slide or cam operation.

???N28 & Q28: one-way roller lever actuator.

???N62 & Q62: 6 inch rod actuator.

???N4 & Q4: large button for easy hand operation.

???N18: Coil spring wobble lever.

N2 & Q2, N4 & Q4, N28 & Q28, N62 & Q62 TYPE

ACTUATOR ADJUSTMENT Vertical Adjustment

Vertical Adjustment Range

Calibration

1.One lever arm serration: 8.18??.

2.One serration of lever arm and fluted washer as a unit: 8??.

3.One serration of lever arm with one serration of fluted washer in opposite direction: 0.18??.

LUBRICATING INSTRUCTIONS for Roller Plunger Switches only (N80, N81, Q8, Q9, Q81)

For maximum life, periodically put a drop or two of lightweight oil on the roller. Specific application conditions will determine lubricating frequency.

Horizontal Adjustment

Horizontal Adjustment Range

???Q??? types; [8] 45?? positions - loosen mounting nut; adjust to new position, seating bracket base pin. Tighten munting nut.

Sealed ???N??? types; loosen mounting nut; adjust to any position; tighten mounting nut.

WARRANTY/REMEDY

Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Commencing with date of shipment, Honeywell???s warranty runs for 18 months. If warranted goods are returned to Honeywell during that period of coverage, Honeywell will repair or replace without charge those items it finds defective. The foregoing is Buyer???s sole remedy and is in lieu of all other warranties, expressed

or implied, including those of merchantability and fitness for a particular purpose.

For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact a nearby sales office. Or call:

1-800-537-6945 USA

1-416-293-8111 Canada

1-815-235-6847 International

INTERNET

http://www.honeywell.sensing.com

info@micro.honeywell.com

Honeywell Inc.

11 West Spring Street

Freeport, Illinois 61032

Printed with Soy Ink