IS3480 QuantumE ??

Scan Engine

User???s Guide

Disclaimer

Honeywell International Inc. (???HII???) reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult HII to determine whether any such changes have been made. The information in this publication does not represent a commitment on the part of HII.

HII shall not be liable for technical or editorial errors or omissions contained herein: nor for incidental or consequential damages resulting from the furnishing, performance, or use of this manual.

This document contains propriety information that is protected by copyright. All rights reserved. No part of this document may be photocopied, reproduced, or translated into another language without the prior written consent of HII.

?? 2004 - 2010 Honeywell International Inc. All rights reserved.

Web Address: www.honeywellaidc.com

Trademarks

Metrologic, QuantumE, CodeGate, MetroSelect and MetroSet2 are trademarks or registered trademarks of Metrologic Instruments, Inc. or Honeywell International Inc.

Microsoft, Windows 95, and Windows are registered trademarks of Microsoft Corporation.

IBM is a trademark of International Business Machines Corporation.

Checkpoint is a registered trademark of Checkpoint Systems, Inc.

Other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies and are the property of their respective owners.

TABLE OF CONTENTS

TABLE OF CONTENTS

iii

INTRODUCTION

QuantumE ?? is a miniature, omni-directional scanning engine with optional single- line scanning capability. The self-contained device is fully enclosed eliminating the need for an external window or custom enclosure. It is designed for use in OEM equipment such as price lookup systems and kiosks. QuantumE s slim design makes it ideal for integration and use with flat-screens.

Key Product Features

???Fully Automatic Scanning Operation

???Custom Configurable Scan Pattern

???User-Replaceable Single Cable Interface to Host (PowerLink Compatible)

???Decoding of All Standard 1D and GS1 DataBar??? (RSS) Bar Codes

???Data Editing

???Seven Beeper Tones

???Configurable Depth of Field

???Flash - Upgradeable Firmware

???CodeGate??

???Sunrise 2005 Compliant

??? Applicable for IBM?? Host applications.

1

INTRODUCTION

Scanner and Accessories

**Contact a customer service representative for additional information on the MVC cable series and the host connections available.

Other items may be ordered for the specific protocol being used. To order additional items, contact the dealer, distributor or customer service. See page 52 for contact information.

2

INTRODUCTION

Scanner and Accessories

Part No.

59-59002x-3

59-59020x-3

59-59235x-N-3

35-35959

59-59249x-N-3

OPTIONAL ACCESSORIES

Description

Keyboard Wedge PowerLink cable

Stand Alone Keyboard PowerLink cable

Low Speed USB Non-Locking Communication Cable straight cord, short strain relief

Utility Flex Cable

Communication Cable, Host end Not Terminated straight cord, short strain relief

Other items may be ordered for the specific protocol being used. To order additional

items, contact the dealer, distributor or customer service. See page 52 for contact information.

Maintenance

Smudges and dirt on the unit's window can interfere with the unit's performance. If the window requires cleaning, use only a mild glass cleaner containing no ammonia. When cleaning the window, spray the cleaner onto a lint free, non- abrasive cleaning cloth then gently wipe the window clean.

If the unit's case requires cleaning, use a mild cleaning agent that does not contain strong oxidizing chemicals. Strong cleaning agents may discolor or damage the unit's exterior.

3

INTRODUCTION

Scanner Components

Figure 1a. Scanner Components

1 Utility Connector Located Under Rubber Seal

The rubber seal protecting the utility connector should only be removed if the utility connector is to be used.

210-Pin RJ45, Female Socket

3Blue, White and Yellow LED Indicators

4Red Output Window (Laser Aperture)

5Pin Hole for Cable Release

6Speaker

7Three M2.5 x 0.45 Threaded Mounting Points

8Two M2.5 x 0.45 Threaded Mounting Points

9Button

Cable Removal

1.Locate the small ???pinhole??? on the side of the QuantumE near the cable (item 5 in figure 1a).

2.Bend an ordinary paperclip into the shape shown.

3.Insert the paperclip (or other small metallic pin) into the ???pinhole???.

4.There will be a faint ???click??? when the cable lock is

4

INTRODUCTION

Caution and Serial Number Labels

Figure 2.

Caution

To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN/IEC 60950-1.

To maintain compliance with standard CSA C22.2 No. 60950-1/UL 60950-1 and norm EN/IEC 60950-1, the power source should meet applicable performance requirements for a limited power source.

Mounting Specifications

Figure 3.

5

INSTALLATION

RS232, RS232 TTL, Light Pen or Laser Emulation

1.Turn off the host device.

2.Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the IS3480.

3.Connect the 9-pin female end of the PowerLink cable to the host device.

Note: Skip to step 6 if receiving power from the host device.

4.Plug the external power supply into the power jack on the PowerLink cable.

Check the AC input requirements of the power supply to make sure the

voltage matches the ACFigure 4. outlet. The outlet must be

located near the equipment and be easily accessible.

5.Connect AC power to the transformer.

6.Turn on the host device.

When the scanner first receives power, the blue LED will turn on; the scanner will simultaneously beep once and flash the white LED.

Plugging the scanner into the serial port of the PC does not guarantee that scanned information will appear at the PC.

A software driver and correct configuration setting are also required for proper communication to occur.

See page 5.

6

INSTALLATION

RS485???

1.Turn off the host device.

2.Plug the male 10-pin RJ45 end of the MVC cable into the 10-pin socket on the IS3480.

3.Connect the other end of the MVC cable to the host device.

4.Turn on the host device.

Figure 5.

When the scanner first receives power, the blue LED will turn on; the scanner will simultaneously beep once and flash the white LED.

Plugging the scanner into the serial port of the PC does not guarantee that scanned information will appear at the PC. A software driver and correct configuration setting are also required for proper communication to occur.

See page 5.

??? Applicable for IBM?? Host applications.

7

INSTALLATION

Keyboard Wedge

When the scanner first receives power, the blue LED will turn on; the scanner will simultaneously beep once and flash the white LED.

Powering the IS3480 directly from the host device can sometimes cause interference with the operation of the scanner or the computer. Not all computers supply the same current through the keyboard port. For this reason, Honeywell recommends using an external power supply. For additional information, contact a customer service representative.

See page 5.

8

INSTALLATION

Stand-Alone Keyboard

1.Turn off the host device.

2.Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the IS3480.

3.Connect the other end of the PowerLink cable to the keyboard port on the host device.

4.Plug the external power supply into the power jack on the PowerLink cable.

When the scanner first receives power, the blue LED will turn on; the scanner will simultaneously beep once and flash the white LED.

Powering the IS3480 directly from the host device can sometimes cause interference with the operation of the scanner or the computer. Not all computers supply the same current through the keyboard port. For this reason, Honeywell recommends using an external power supply. For additional information contact a customer service representative.

See page 5.

9

When the scanner first receives power, the blue LED will turn on; the scanner will simultaneously beep once and flash the white LED.

Plugging the scanner into the USB port of the PC does not guarantee that scanned information will appear at the PC. A software driver and correct configuration setting are also required for proper communication to occur.

See page 5.

10

INSTALLATION

Notes for Laser Emulation

IS3480-104 Only

The IS3480-104 leaves the factory with the Laser Emulation Mode enabled.

If the Recall Defaults bar code is scanned while reconfiguring the scanner, the laser emulation mode will no longer be enabled.

Scan the following bar code to re-enable the laser emulation interface. This feature is only supported for IS3480-104 models.

Enable Laser Emulation Mode

?? 9 9 9 9 7 9

11

SCANNER OPERATION

Configurable Primary and Secondary Scan Pattern Modes

There are two configurable scan pattern modes available with the IS3480.

???The primary scan pattern mode is the default scan pattern active when the scanner starts.

???The secondary scan pattern mode is activated by pressing the button located on the side of the scanner. This mode is also referred to as the button mode. For additional information on QuantumE???s button modes and an example of each, please refer to Configurable Button Functions below.

The scanner returns to the primary scan pattern mode after a double click of the button or if the unit has not scanned a bar code for the duration of a pre-configured time limit.

Each pattern mode can be configured to use one of three scan patterns listed below. Please refer to the MetroSelect Configuration Guide for information on changing the default scan pattern settings.

???all scan lines on (omnidirectional reading)

???single-line (menu reading)

???horizontal raster

If CodeGate is enabled, it will apply to the secondary pattern mode when scanning. For detailed information on CodeGate and the button refer to the Configurable Button Functions.

Configurable Button Functions

The button on the side of the IS3480 can be configured to function in one of four modes.

???Button Click Mode, with CodeGate Enabled (Default)

???Button Click Mode, with CodeGate Disabled

???Button Hold Mode, with CodeGate Enabled

???Button Hold Mode, with CodeGate Disabled

The following pages include examples of how the button will function when the unit has been configured to operate in each of the four button modes.

12

SCANNER OPERATION

Configurable Button Functions

SECONDARY SCAN PATTERN

BUTTON CLICK MODE WITH CODEGATE ENABLED

For illustration purposes the unit???s primary scan pattern has been set to all scan lines (omnidirectional reading) and the secondary pattern has been set to single-line (menu reading) with a 10 second button click timeout configured.

1.The primary scan pattern is active when the scanner starts.

2.To activate the secondary scan pattern, press and release the button.

3.To decode and transmit the bar code, press and release the button.

The scanner will beep once.

4.To reactivate the primary scan pattern, double click the button or after 10-seconds of no-scanning the unit will automatically reactivate the primary pattern.

13

SCANNER OPERATION

Configurable Button Functions

SECONDARY SCAN PATTERN

BUTTON CLICK MODE WITH CODEGATE DISABLED

For illustration purposes the unit???s primary scan pattern has been set to all scan lines (omnidirectional reading) and the secondary pattern has been set to single-line (menu reading) with a 10 second button click timeout configured.

1.The primary scan pattern is active when the scanner starts.

2.To activate the secondary scan pattern, press and release the button.

3.The unit will beep once as it decodes and transmits the bar code.

4.To reactivate the primary scan pattern, double click the button or after 10-seconds of no-scanning the unit will automatically reactivate the primary pattern.

14

SCANNER OPERATION

Configurable Button Functions

SECONDARY SCAN PATTERN

BUTTON HOLD MODE WITH CODEGATE ENABLED

For illustration purposes the unit???s primary scan pattern has been set to all scan lines (omnidirectional reading) and the secondary pattern has been set to single-line (menu reading) with a 10 second button click timeout configured.

1.The primary scan pattern is active when the scanner starts.

2.To activate the secondary scan pattern, press and hold the button.

3.To scan the bar code, align the laser line over the bar code while continuing to hold down the button.

4.To transmit the bar code, release the button. The scanner will beep once.

5.To scan and transmit additional bar codes, repeat steps 2 through 4.

6.The primary scan pattern will automatically reactivate after the button is released and no bar code is present in the scan field.

15

SCANNER OPERATION

Configurable Button Functions

SECONDARY SCAN PATTERN

BUTTON HOLD MODE WITH CODEGATE DISABLED

For illustration purposes the unit???s primary scan pattern has been set to all scan lines (omnidirectional reading) and the secondary pattern has been set to single-line (menu reading) with a 10 second button click timeout configured.

1.The primary scan pattern is active when the scanner starts.

2.To activate the secondary scan pattern, press and hold the button.

3.To scan and transmit the bar code, align the laser line over the bar code while continuing to hold down the button. The scanner will beep once to indicate the bar code has been scanned and transmitted.

4.The primary scan pattern will automatically reactivate after the button is released and no bar code is present in the scan field.

16

SCANNER OPERATION

Sweet Spot Mode

The sweet spot mode is used to determine where the maximum read rate area or ???sweet spot??? is located for a specific bar code type. When activated this mode provides visual and audible feedback indicating how the scanner is scanning.

For further information on the sweet spot mode and instructions on how to enable it, refer the MetroSelect Configuration Guide (00-02407).

17

SCANNER OPERATION

Audible Indicators

When the IS3480 is in operation, it can provide audible feedback. These sounds indicate the status of the scanner. Eight settings are available for the tone of the beep (normal, six alternate tones and no tone). For instruction on how to change the tone of the beeper, refer to the MetroSelect Configuration Guide (00-02407).

One Beep

When the scanner first receives power the white LED will flash, the blue LED will turn on and the scanner will beep once (the white LED will remain on for the duration of the beep). The scanner is now ready to scan.

When the scanner successfully reads a bar code, the white LED will flash and the scanner beeps once (if configured to do so). If the scanner does not beep once and the white light does not flash, then the bar code has not been successfully read.

Razzberry Tone

This is a failure indicator. Refer to Failure Mode Indicators on page 20.

Three Beeps - during operation

When placing the scanner in configuration mode, the white LED will flash while the scanner simultaneously beeps three times. The white and blue LEDs will continue to flash until the unit exits configuration mode. Upon exiting configuration mode, the scanner will beep three times and the white LED will stop flashing.

When configured, three beeps can also indicate a communications timeout during normal scanning mode.

When using one-code-programming, the scanner will beep three times: the current selected tone, followed by a short pause, a high tone and a low tone. This tells the user that the single configuration bar code has successfully configured the scanner.

Three Beeps - on power up

This is a failure indicator. Refer to Failure Mode Indicators on page 20.

18

SCANNER OPERATION

Visual Indicators

There are four LEDs located on the top of the IS3480. When the scanner is on, the flashing or constant illumination of the LEDs indicates the status of the current scan and the scanner.

No LEDs

The LEDs will not be illuminated if the scanner is not receiving power from the host or transformer. They are also not illuminated when all lasers are turned off for any reason.

Steady Blue

When the laser is active, the blue LED is illuminated. The blue LED will remain illuminated until the laser is deactivated.

Steady Blue and Single White Flash

When the scanner successfully reads a bar code, the white LED will flash and the scanner will beep once. If the white LED does not flash or the scanner does not beep once, then the bar code has not been successfully read.

Steady White and Blue

After a successful scan, the scanner transmits the data to the host device. Some communication modes require that the host inform the scanner when data is ready to be received. If the host is not ready to accept the information, the scanner???s white LED will remain on until the data can be transmitted.

Alternating Blue and White Flashes

This indicates the scanner is in program mode. A razzberry tone indicates that an invalid bar code has been scanned in this mode.

Steady White, Blue Off

This indicates the scanner may be waiting for communication from the host.

19

SCANNER OPERATION

Failure Mode Indicators

Flashing Blue and One Razzberry Tone

This indicates that the scanner has experienced a laser subsystem failure. Return the unit to an authorized service center for repair.

Flashing Blue and White and Two Razzberry Tones

This indicates that the scanner has experienced a motor failure. Return the unit to an authorized service center for repair.

Continuous Razzberry Tone with Both LEDs Off

If, upon power up, the scanner emits a continuous razzberry tone, then the scanner has an electronic failure. Return the unit to an authorized service center for repair.

Three Beeps - On Power Up

If the scanner beeps three times on power up then, the nonvolatile memory that holds the scanner configuration has failed. Return the unit to an authorized service center for repair.

20

SCANNER OPERATION

Depth of Field Specifications*

Normal Scan Zone

Specifications are based on a 0.33 mm (13 mil) bar code.

Figure 9. Normal Depth of Field

* All specifications are subject to change without notice.

21

SCANNER OPERATION

Depth of Field Specifications*

Reduced Scan Zone

Specifications are based on a 0.33 mm (13 mil) bar code.

Figure 10. Reduced Depth of Field

* All specifications are subject to change without notice.

22

SCANNER OPERATION

Depth of Field by Bar Code Element Width*

Normal Scan Zone

MINIMUM BAR CODE ELEMENT WIDTH

Figure 11. Normal Scan Zone by Bar Code Element Width

* All specifications are subject to change without notice.

23

SCANNER OPERATION

Depth of Field by Bar Code Element Width*

Reduced Scan Zone

MINIMUM BAR CODE ELEMENT WIDTH

Figure 12. Reduced Scan Zone by Bar Code Element Width

* All specifications are subject to change without notice.

24

SCANNER OPERATION

IR Activation Range*

QuantumE???s default power save mode??? is Laser OFF. This power save mode turns the laser off after a configured period of non-use. Any movement detected by the IR in the activation area will cause the scanner to exit power save mode. The laser will automatically turn back on preparing the scanner for bar code recognition, decoding and transmission.

Figure 13. IR Activation Range

* All specifications are subject to change without notice.

???Refer to the MetroSelect Configuration Guide (00-02407) for additional information on configurable power save modes.

25

TROUBLESHOOTING GUIDE

The following guide is for reference purposes only. Contact a Honeywell representative to preserve the limited warranty terms on page 47.

All Interfaces

Check the transformer, outlet and power strip. Make sure the cable is plugged into the scanner.

Some host systems cannot supply enough current to power the IS3480. Use the power supply included with the scanner.

Adjust the same symbol timeout for a longer time increment.

Enable the beeper.

Select a tone.

The unit powers up but does not scan and/or beep.

The unit is trying to scan a particular symbology that is not enabled.

The scanner has been programmed for a character length lock, or a minimum length and bar code being scanned does not satisfy the configured criteria.

UPC/EAN, Code 39, Interleaved 2 of 5, Code 93, Code 128 and Codabar are enabled by default. Verify that the type of bar code being read has been selected

Verify that the bar code that is being scanned falls into the criteria.

Typical of Non-UPC/EAN codes. The scanner defaults to a minimum of 4 character bar code.

Verify that the scanner???s data format matches the format required by the host.

Make sure that the scanner is connected to the proper host port.

26

TROUBLESHOOTING GUIDE

All Interfaces

The unit scans a bar code, but locks up after the first scan (the white LED stays on).

Scanner beeps at some bar codes and NOT for others of the same bar code symbology.

During power up the unit beeps three times.

During power up the unit razzes continuously.

During power up the unit razzes once and the blue LED flashes.

During power up the unit razzes twice and both LEDs flash.

The scanner is configured to support some form of host handshaking but is not receiving the signal.

The bar code may have been printed incorrectly.

The scanner is not configured correctly for the type of bar code.

The minimum symbol length setting does not work with the bar code.

There is a non-volatile RAM failure.

There has been a diagnostic failure.

There is a VLD failure.

There is a scanner motor failure.

If the scanner is setup to support ACK/NAK, RTS/CTS, XON/XOFF or D/E, verify that the host cable and host are supporting the handshaking properly.

Check if it is a check digit, character or border problem.

Check if check digits are set properly.

Check if the correct minimum symbol length is set.

Contact a service representative.

Contact a service representative.

Contact a service representative.

Contact a service representative.

27

TROUBLESHOOTING GUIDE

28

DESIGN SPECIFICATIONS

IS3480

Operational

Normal Depth of Field: 25 mm - 280 mm (1"- 11") Reduced Depth of Field: 25 mm - 150 mm (1"- 6")

Omni Scan

Scan Speed: 1650 scan lines per second No. of Scan Lines: 20

Single-Line

Scan Speed: 80 scan lines per second No. of Scan Lines: 1

Raster

0.33 mm (13 mil) bar code

??? Applicable for IBM?? Host applications. Specifications subject to change without notice.

29

DESIGN SPECIFICATIONS

IS3480

Mechanical

For regulatory compliance information, see pages 44 ??? 46.

Environmental

Operating Temperature: -20??C to 40??C (-4??F to 104??F)

Storage Temperature: -40??C to 60??C (-40??F to 140??F)

Humidity: 5% to 95% relative humidity, non-condensing Contaminants: Sealed to resist airborne particulate contaminants

Ventilation: None required

Specifications subject to change without notice.

30

APPLICATIONS AND PROTOCOLS

The model number on each scanner includes the scanner number and factory default communications protocol.

47Keyboard Wedge, Stand-Alone Keyboard and RS232 Transmit/Receive

104RS232 Transistor to Transistor Logic (TTL), Laser Emulation

???Applicable for IBM?? Host applications.

The IS3480 scanner with Built-in PC Keyboard Wedge Interface is designed to be used for keyboard emulation only. Many RS232 configurable functions (e.g. formatting) available in other Honeywell scanners are also available as keyboard wedge functions.

The following are the most important selectable options specific to the keyboard wedge.

Keyboard Type

???** AT (includes IBM?? PS2 models 50, 55, 60, 80)

???IBM PS2 (includes models 30, 70, 8556)

Keyboard Country Type

**Default setting. Refer to the MetroSelect?? Configuration Guide

(MLPN 00-02407) or MetroSet2???s help files for information on how to change the default settings.

31

CONFIGURATION MODES

The IS3480 Series scanner has three modes of configuration.

???Bar Codes

The IS3480 can be configured by scanning the bar codes included in the Single-Line Configuration Guide or the Supplemental Configuration Guide. The manuals are available for download at www.honeywellaidc.com.

???MetroSet2

This user-friendly Windows??-based configuration program allows you to simply ???point-and-click??? at the desired imager options. MetroSet2 is available for download at www.honeywellaidc.com.

???Serial Programming

This mode of configuration is ideal for OEM applications. Serial programming mode gives the end-user the ability to send a series of commands using the serial port of the host system. The commands are equivalent to the numerical values of the bar codes located in the MetroSelect Single-Line Configuration Guide.

32

UPGRADING THE FIRMWARE

The IS3480 is part of Honeywell's line of scanners with flash upgradeable firmware. The upgrade process requires, a new firmware file supplied to the customer by a customer service representative??? and Honeywell's MetroSet2 software??????. A personal computer running Windows 95 or greater with an available RS232 serial or USB port is required to complete the upgrade.

Do not use the standard cable supplied with Keyboard Wedge or RS485??? IS3480 interface kits for firmware upgrades. If using USB or RS232 for the upgrade process, the standard USB or RS232 cable provided with the scanner can be used.

To upgrade the firmware in the IS3480:

1.Plug the scanner into a serial communication port on the host system.

2.Start the MetroSet2 software.

3.Click on the plus sign (+) next to POS Scanners to expand the supported scanner list.

4.Choose the Quantum E/T from the list.

5.Click on the Configure Quantum E/T Scanner button.

6.Choose Flash Utility from the options list located on the left side of the screen.

7.Click on the Open File button in the Flash Utility window.

8.Locate and open the flash upgrade file supplied.

9.Select the COM port that the scanner is connected to on the host system.

10.Verify the settings listed in the Flash Utility window.

11.Click on the Flash Scanner button to begin the flash upgrade.

12.A message will appear on the screen when the upgrade is complete.

???See Contact Information on page 47.

??????MetroSet2 is available for download, at no additional cost, from www.honeywellaidc.com.

???Applicable for IBM?? Host applications.

33

DEFAULT SETTINGS - COMMUNICATION PARAMETERS

Many functions of the scanner can be "configured" - that is enabled or disabled. The scanner is shipped from the factory configured to a set of default conditions. The default parameter of the scanner has an asterisk ( * ) in the charts on the following pages. If an asterisk is not in the default column then the default setting is Off or Disabled. Not every interface supports every parameter. If the interface supports a parameter listed in the charts on the following pages, a check mark (???) will appear.

??? Applicable for IBM?? Host applications.

34

DEFAULT SETTINGS - COMMUNICATION PARAMETERS

??? Applicable for IBM?? Host applications.

35

DEFAULT SETTINGS - COMMUNICATION PARAMETERS

Transmit UPC-A

Check Digit

Transmit UPC-E

Check Digit

Expand UPC-E

Convert UPC-A to EAN-13

Transmit Lead Zero on UPC-E

Convert EAN-8 to EAN-13

Transmit UPC-A

Number System

Transmit UPC-A

Manufacturer ID#

Transmit UPC-A Item ID#

Transmit Codabar

Start/Stop Characters

CLSI Editing (Enable)

Transmit Mod 43 Check Digit on Code 39

Transmit Code 39

Stop/Start Characters

Transmit Mod 10/ITF

*?????? ??????

?????? ??????

?????? ??????

?????? ??????

?????? ??????

?????? ??????

* ?????? ??????

* ?????? ??????

*?????? ??????

?????? ??????

?????? ??????

?????? ??????

?????? ??????

?????? ??????

??? Applicable for IBM?? Host applications.

36

??? Applicable for IBM?? Host applications.

37

DEFAULT SETTINGS - COMMUNICATION PARAMETERS

Supplements are not Required

Two Digit Redundancy

Five Digit Redundancy

100 msec to Find Supplement Programmable in 100msec steps (MAX 800 msec)

Coupon Code 128

Programmable Code

Lengths

Programmable Prefix

Characters

Programmable Suffix

Characters

Prefixes for individual Code Types

Editing

Inter Scan-Code Delay Programmable

(100 ??sec steps)

Function/Control Key

Support

Minimum Element Width Programmable in 5.6 ??sec steps

Normal Depth of Field

Reduced Depth of Field

Sweet Spot Mode

*?????? ?????? ??????

?????? ?????? ??????

?????? ?????? ??????

??? Applicable for IBM?? Host applications.

38

SCANNER AND CABLE TERMINATIONS

Scanner Pinout Connections

The IS3480 scanner interfaces terminate to a 10-pin modular socket.

The serial number label indicates the interface enabled when the scanner is shipped from the factory.

Figure 14.

IS3480-47 Keyboard Wedge

and Stand-Alone Keyboard

Pin Function

1Ground

2RS232 Transmit Output

3RS232 Receive Input

4PC Data

5PC Clock

6KB Clock

7PC +5V

8KB Data

9+5VDC

10 Shield Ground

IS3480-38

RS232 Low Speed USB

Pin Function

1Ground

2RS232 Transmit Output

3RS232 Receive Input

4RTS Output

5CTS Input

6D+

7V_USB

8D-

9+5VDC

10 Shield Ground

IS3480-41

RS232 and Light Pen Emulation

Pin Function

1Ground

2RS232 Transmit Output

3RS232 Receive Input

4RTS Output

5CTS Input

6DTR Input/LTPN Source

7Reserved

8LTPN Data

9+5VDC

10 Shield Ground

IS3480-11

RS485???

Pin Function

1Ground

2RS232 Transmit Output

3RS232 Receive Input

4RTS Output

5CTS Input

6DTR Input

7IBM B-Transmit

8IBM A+ Receive

9+5VDC

10 Shield Ground

SCANNER AND CABLE TERMINATIONS

Figure 15.

IS3480-104 RS232, RS232 TTL, or Laser Emulation

Pin Function

1Ground

2RS232 Transmit Output

3RS232 Receive Input

4RTS Output (TTL RS232) / Flip Sense

5CTS Input (TTL RS232) / Trigger Emulation Output

6DTR Input (TTL RS232) / Scan Enable

7Receive (TTL RS232) / Good Read

8Transmit (TTL RS232) / Scan Data

9+5VDC

10 Shield Ground

40

SCANNER AND CABLE TERMINATIONS

Figure 16.

Figure 17.

Zero Insertion Force Connector (ZIF), 6-pin Utility Connector

Pin Function

1Aux +5V: Power out. Can supply up to 100mA @ 5V.

Good Read: Open-collector output. Low-going 20mA output for duration of

232 ms at a baud rate of 9600. Represents a successful bar code read. Can be used to drive an external LED. Requires an external current limiting resistor of 182 ohms.

Aux Beeper: Open-collector output. Pulsed output (50mA sink current)

3at a frequency of 16.67 kHz for duration of 60 ms. Represents a successful bar code read. Can be used to drive an external beeper.

4Aux Active: Active HIGH input signal for external trigger. A HIGH on this pin is equivalent to activating the scan push button.

5Aux Out: Reserved.

6Ground

41

SCANNER AND CABLE TERMINATIONS

Cable Connector Configurations (Host End)

Stand Alone Keyboard PowerLink

Cable 59-59020x-3

PinFunction

1PC Data

2No Connect

3Power Ground

4+5VDC PC Power to KB

6 No Connect

42

SCANNER AND CABLE TERMINATIONS

Cable Connector Configurations (Host End)

Honeywell will supply an adapter cable with a 5-pin DIN male connector on one end and a 6-pin mini DIN female connector on the other. According to the termination required, connect the appropriate end of the adapter cable to the PowerLink cable, leaving the necessary termination exposed for connecting to the keyboard and the keyboard port on the PC.

43

REGULATORY COMPLIANCE

Safety

ITE Equipment

IEC 60950-1: 2005+A11, EN 60950-1:2006+A11

Laser

Laser Class 1: IEC 60825-1:2007+A1+A2,

EN 60825-1:2007+A1+A2

Caution

Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous laser light exposure. Under no circumstances should the customer attempt to service the laser scanner. Never attempt to look at the laser beam, even if the scanner appears to be nonfunctional. Never open the scanner in an attempt to look into the device. Doing so could result in hazardous laser light exposure. The use of optical instruments with the laser equipment will increase eye hazard.

Atenci??n

La modificaci??n de los procedimientos, o la utilizaci??n de controles o ajustes distintos de los especificados aqu??, pueden provocar una luz de l??ser peligrosa. Bajo ninguna circunstancia el usuario deber?? realizar el mantenimiento del l??ser del esc??ner. Ni intentar mirar al haz del l??ser incluso cuando este no est?? operativo. Tampoco deber?? abrir el esc??ner para examinar el aparato. El hacerlo puede conllevar una exposici??n peligrosa a la luz de l??ser. El uso de instrumentos ??pticos con el equipo l??ser puede incrementar el riesgo para la vista.

Attention

L'emploi de commandes, r??glages ou proc??d??s autres que ceux d??crits ici peut entra??ner de graves irradiations. Le client ne doit en aucun cas essayer d'entretenir lui-m??me le scanner ou le laser. Ne regardez jamais directement le rayon laser, m??me si vous croyez que le scanner est inactif. N'ouvrez jamais le scanner pour regarder dans l'appareil. Ce faisant, vous vous exposez ?? une rayonnement laser q?? ??st hazardous. L'emploi d'appareils optiques avec cet ??quipement laser augmente le risque d'endommagement de la vision.

Achtung

Die Verwendung anderer als der hier beschriebenen Steuerungen, Einstellungen oder Verfahren kann eine gef??hrliche Laserstrahlung hervorrufen. Der Kunde sollte unter keinen Umst??nden versuchen, den Laser-Scanner selbst zu warten. Sehen Sie niemals in den Laserstrahl, selbst wenn Sie glauben, da?? der Scanner nicht aktiv ist. ??ffnen Sie niemals den Scanner, um in das Ger??t hineinzusehen. Wenn Sie dies tun, k??nnen Sie sich einer gef??hrlichen Laserstrahlung aussetzen. Der Einsatz optischer Ger??te mit dieser Laserausr??stung erh??ht das Risiko einer Sehsch??digung.

Attenzione

L???utilizzo di sistemi di controllo, di regolazioni o di procedimenti diversi da quelli descritti nel presente Manuale pu?? provocare delle esposizioni a raggi laser rischiose. Il cliente non deve assolutamente tentare di riparare egli stesso lo scanner laser. Non guardate mai il raggio laser, anche se credete che lo scanner non sia attivo. Non aprite mai lo scanner per guardare dentro l???apparecchio. Facendolo potete esporVi ad una esposizione laser rischiosa. L???uso di apparecchi ottici, equipaggiati con raggi laser, aumenta il rischio di danni alla vista..

44

REGULATORY COMPLIANCE

EMC

Emissions

FCC Part 15, ICES-003, CISPR 22, EN 55022

Immunity

CISPR 24, EN 55024

NOTE: Immunity performance is not guaranteed for scanner cables greater than 3 meters in length when fully extended.

Changes or modifications not expressly approved by the party responsible for compliance could void the user???s authority to operate the equipment.

Class A Devices

The following is applicable when the scanner cable is greater in length than 3 meters (9.8 feet) when fully extended:

Les instructions ci-dessous s???appliquent aux cables de scanner d??passant 3 m??tres (9.8 pieds) de long en extension maximale:

Folgendes trifft zu, wenn das Scannerkabel l??nger als 3 Meter ist:

This equipment has been tested and found to comply with limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at their own expense. Any unauthorized changes or modifications to this equipment could void the user???s authority to operate this device.

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Notice

This Class A digital apparatus complies with Canadian ICES-003.

Remarque

Cet appareil num??rique de classe A est conforme ?? la norme canadienne NMB-003.

European Standard

Warning

This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

Funkst??reigenschaften nach EN55022

Warnung!

Dies ist eine Einrichtung der Klasse A. Diese Einrichtung kann im Wohnbereich Funkst??rungen verursachen. In diesem Fall kann vom Betreiber verlangt werden, angemessene Massnahmen durchzuf??hren.

45

REGULATORY COMPLIANCE

EMC

Changes or modifications not expressly approved by the party responsible for compliance could void the user???s authority to operate the equipment.

Standard Europeo

Attenzione

Questo e??? un prodotto di classe A. Se usato in vicinanza di residenze private potrebbe causare interferenze radio che potrebbero richiedere all???utilizzatore opportune misure.

Attention

Ce produit est de classe ???A???. cause d???interf??rences radio. mesures ad??quates.

Dans un environnement domestique, ce produit peut ??tre la Dans ce cas l???utiliseteur peut ??tre amen?? ?? predre les

Class B Devices

The following is applicable when the scanner cable is less than 3 meters (9.8 feet) in length when fully extended:

Les instructions ci-dessous s???appliquent aux cables de scanner ne d??passant pas 3 m??tres (9.8 pieds) de long en extension maximale:

Folgendes trifft zu, wenn das Scannerkabel k??rzer als 3 Meter ist:

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

???Reorient or relocate the receiving antenna

???Increase the separation between the equipment and receiver

???Connect the equipment into an outlet on a circuit different from that to which the receiver is connected

???Consult the dealer or an experienced radio/TV technician for help

Notice

This Class B digital apparatus complies with Canadian ICES-003.

Remarque

Cet appareil num??rique de classe B est conforme ?? la norme canadienne NMB-003.

46

LIMITED WARRANTY

Honeywell International Inc. ("HII") warrants its products and optional accessories to be free from defects in materials and workmanship and to conform to HII???s published specifications applicable to the products purchased at the time of shipment. This warranty does not cover any HII product which is (i) improperly installed or used; (ii) damaged by accident or negligence, including failure to follow the proper maintenance, service, and cleaning schedule; or (iii) damaged as a result of (A) modification or alteration by the purchaser or other party, (B) excessive voltage or current supplied to or drawn from the interface connections, (C) static electricity or electro-static discharge, (D) operation under conditions beyond the specified operating parameters, or (E) repair or service of the product by anyone other than HII or its authorized representatives.

This warranty shall extend from the time of shipment for the duration published by HII for the product at the time of purchase ("Warranty Period"). Any defective product must be returned (at purchaser???s expense) during the Warranty Period to HII factory or authorized service center for inspection. No product will be accepted by HII without a Return Materials Authorization, which may be obtained by contacting HII. In the event that the product is returned to HII or its authorized service center within the Warranty Period and HII determines to its satisfaction that the product is defective due to defects in materials or workmanship, HII, at its sole option, will either repair or replace the product without charge, except for return shipping to HII.

EXCEPT AS MAY BE OTHERWISE PROVIDED BY APPLICABLE LAW, THE

FOREGOING WARRANTY IS IN LIEU OF ALL OTHER COVENANTS OR

WARRANTIES, EITHER EXPRESSED OR IMPLIED, ORAL OR WRITTEN,

INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTIES OF

MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, OR NON-

INFRINGEMENT.

HII???S RESPONSIBILITY AND PURCHASER???S EXCLUSIVE REMEDY UNDER

THIS WARRANTY IS LIMITED TO THE REPAIR OR REPLACEMENT OF THE

DEFECTIVE PRODUCT WITH NEW OR REFURBISHED PARTS. IN NO

EVENT SHALL HII BE LIABLE FOR INDIRECT, INCIDENTAL, OR

CONSEQUENTIAL DAMAGES, AND, IN NO EVENT, SHALL ANY LIABILITY

OF HII ARISING IN CONNECTION WITH ANY PRODUCT SOLD HEREUNDER

(WHETHER SUCH LIABILITY ARISES FROM A CLAIM BASED ON

CONTRACT, WARRANTY, TORT, OR OTHERWISE) EXCEED THE ACTUAL

AMOUNT PAID TO HII FOR THE PRODUCT. THESE LIMITATIONS ON

LIABILITY SHALL REMAIN IN FULL FORCE AND EFFECT EVEN WHEN HII

MAY HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH INJURIES,

LOSSES, OR DAMAGES. SOME STATES, PROVINCES, OR COUNTRIES DO

NOT ALLOW THE EXCLUSION OR LIMITATIONS OF INCIDENTAL OR

CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION

MAY NOT APPLY TO YOU.

47

LIMITED WARRANTY

All provisions of this Limited Warranty are separate and severable, which means that if any provision is held invalid and unenforceable, such determination shall not affect the validity of enforceability of the other provisions hereof. Use of any peripherals not provided by the manufacturer may result in damage not covered by this warranty. This includes but is not limited to: cables, power supplies, cradles, and docking stations. HII extends these warranties only to the first end- users of the products. These warranties are non-transferable.

The duration of the limited warranty for the IS3480 is three (3) year(s). The accessories have a 90 day limited warranty from the date of manufacture.

48

PATENTS

For patent information, please refer to www.honeywellaidc.com/patents.

49

INDEX

A

INDEX

CUSTOMER SUPPORT

Technical Assistance

If you need assistance installing or troubleshooting your device, please call your distributor or the nearest technical support office:

North America/Canada

Telephone: (800) 782-4263

E-mail: hsmnasupport@honeywell.com

Latin America

Telephone: (803) 835-8000

Telephone: (800) 782-4263

E-mail: hsmlasupport@honeywell.com

Brazil

Telephone: +55 (11) 5185-8222

Fax: +55 (11) 5185-8225

E-mail: brsuporte@honeywell.com

Mexico

Telephone: 01-800-HONEYWELL (01-800-466-3993)

E-mail: soporte.hsm@honeywell.com

Europe, Middle East, and Africa

Telephone: +31 (0) 40 7999 393

Fax: +31 (0) 40 2425 672

E-mail: hsmeurosupport@honeywell.com

Hong Kong

Telephone: +852-29536436

Fax: +852-2511-3557

E-mail: aptechsupport@honeywell.com

Singapore

Telephone: +65-6842-7155

Fax: +65-6842-7166

E-mail: aptechsupport@honeywell.com

China

Telephone: +86 800 828 2803

Fax: +86-512-6762-2560

E-mail: aptechsupport@honeywell.com

Japan

Telephone: +81-3-3839-8511

Fax: +81-3-3839-8519

E-mail: aptechsupport@honeywell.com

Online Technical Assistance

You can also access technical assistance online at www.honeywellaidc.com.

52

CUSTOMER SUPPORT

Product Service and Repair

Honeywell International Inc. provides service for all its products through service centers throughout the world. To obtain warranty or non-warranty service, contact the appropriate location below to obtain a Return Material Authorization number (RMA #) before returning the product.

North America

Telephone: (800) 782-4263

E-mail: hsmnaservice@honeywell.com

Latin America

Telephone: (803) 835-8000

Telephone: (800) 782-4263

Fax: (239) 263-9689

E-mail: laservice@honeywell.com

Brazil

Telephone: +55 (11) 5185-8222

Fax: +55 (11) 5185-8225

E-mail: brservice@honeywell.com

Mexico

Telephone: 01-800-HONEYWELL (01-800-466-3993)

Fax: +52 (55) 5531-3672

E-mail: mxservice@honeywell.com

Europe, Middle East, and Africa

Telephone: +31 (0) 40 2901 633

Fax: +31 (0) 40 2901 631

E-mail: euroservice@honeywell.com

Hong Kong

Telephone: +852-29536436

Fax: +852-2511-3557

E-mail: apservice@honeywell.com

Singapore

Telephone: +65-6842-7155

Fax: +65-6842-7166

E-mail: apservice@honeywell.com

China

Telephone: +86 800 828 2803

Fax: +86-512-6762-2560

E-mail: apservice@honeywell.com

Japan

Telephone: +81-3-3839-8511

Fax: +81-3-3839-8519

E-mail: apservice@honeywell.com

53

CUSTOMER SUPPORT

Online Product Service and Repair Assistance

You can also access product service and repair assistance online at www.honeywellaidc.com.

54

Honeywell Scanning & Mobility

9680 Old Bailes Road Fort Mill, SC 29707 www.honeywellaidc.com

00-02026 Rev H

11/10