Mini Submersible / Fountain / Pond Pump
Read this material before using this product. Failure to do so can result in serious injury. SAVE THIS MANUAL.
When unpacking, make sure that the product is intact and undamaged. If any parts are missing or broken, please call
Visit our website at: http://www.harborfreight.com
Copyright?? 2011 by Harbor Freight Tools??. All rights reserved. No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools. Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly from the product described herein. Tools required for assembly and service may not be included.
Before
The pump can be connected to any
The plug must have a supply voltage of 120 V~ at 60 Hz.
CAUTION:
This pump has been evaluated for use with clear water only. Do not use in or around swimming pools.
WARNING:
IMPORTANT! For your own safety ??? before starting to run the pump, please have the following items checked by an expert:
1.To reduce the risk of electric shock, use only on portable
2.Risk of electric shock ??? This pump is supplied with a grounding conductor and
3.Risk of electric shock ??? This pump has not been investigated for use in swimming pool areas.
4.The electrical connections must be protected from moisture.
5.If there is danger of flooding, the electrical connections must be taken to higher ground.
6.Circulation of caustic fluids, as well as the circulation of abrasive materials, must be avoided at all costs.
7.The pump must be protected from frost.
8.The pump must be protected from running dry.
9.Access by children should also be prevented with appropriate measures.
10.To avoid the possibility of the pump plug or receptacle getting wet, position pump to one side of a wall mounted receptacle to prevent water from dripping onto the receptacle or plug. The user should arrange a ???drip loop??? in the cord connecting the pump to a receptacle. The ???drip loop??? is that part of the cord below the level of the receptacle, or the connector if an extension cord is used, to prevent water traveling along the cord and coming in contact with the receptacle.
11.WARNING: Handling the Power Cord on this product will expose you to lead, a chemical known to the State of California to cause cancer, and birth defects or other reproductive harm. Wash hands after handling. (California Health & Safety Code ?? 25249.5, et seq.)
12.The warnings, precautions, and instructions discussed in this instruction manual cannot cover all possible conditions and situations that may occur. It must
be understood by the operator that common sense and caution are factors which cannot be built into this product, but must be supplied by the operator.
Fluid Type
The Pump is designed for use with salt and fresh water with a maximum temperature of 77?? F (25??C). Do not use in hot water. Do not use the pump for other fluids, especially not fuels, cleaning fluids, or other chemical products.
Specifications
Save This Manual
Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product???s serial
number in the back of the manual near the assembly diagram (or month and year of purchase if product has no number). Keep this manual and the receipt in a safe and dry place for future reference.
Installation
Please note!
1.The pump is designed to be used in aquariums/water features.
2.The pump must be placed on the bottom of the aquarium/water feature. To ensure that the pump works properly, keep the bottom of the aquarium/ water feature free from sludge and dirt of all kinds.
3.For proper cooling, only operate pump when it is completely submerged. See the Specifications
Chart for the maximum lift for your particular pump.
4.NOTE: Pumps models 68393 and 68395 each come with their own extension set. To attached entension to the pump, thread selected extension outlet to top of extension. Then thread bottom of extension to extension valve. Use adapter to connect assembled extension to water outlet at top of pump housing.
Power Supply
1.The pump is equipped with a shock???proof plug according to regulations.
The pump is designed to be connected to 120 V~, 60 Hz GFCI???protected safety socket.
2.Make sure that the socket is sufficiently secured and is in excellent condition.
3.When the plug is inserted into the socket the pump will operate.
WARNING! If the power cord or plug is damaged, do not use the pump. The power cord or plug may only be repaired by a certified electrician.
Operation
1.Set the pump on a level spot in the aquarium/water feature. The suction cups must be in contact with the aquarium/fountain floor or a smooth platform.
NOTE: Do not plug in pump yet.
CAUTION: Verify pump is adequately supported. If you use an additional hose and
2.Once the pump is fully submerged and adequately supported, shift the regulator to adjust flow rate.
3.NOTE: After reading these instructions, consider the following points before starting the pump:
a.Verify that the pump rests on the floor of the shaft, if it is not suspended by the power cord.
b.Verify that the delivery pipe is properly connected.
c.Verify that the electrical connection is 120 V~, 60 Hz.
d.Verify that the electrical socket is in good condition.
e.Verify that water and moisture cannot get near the power supply socket.
f.Verify that the pump is installed so as to prevent running dry.
4.Once you???ve verified that the pump has a proper setup, dry your hands and plug the power cord into the electrical outlet to begin pump operation.
Maintenance
TO PREVENT SERIOUS INJURY FROM
ACCIDENTAL OPERATION: Unplug the Pump from its electrical
outlet before performing any inspection, maintenance, or cleaning procedures.
If the pump is moved to a different aquarium or water feature, flush it out with clean water and dry before setting up in new water feature.
If cord is damaged, it must be replaced by a qualified technician.
Quarterly Maintenance
The below maintenance should be performed at least once every 3 months under optimal conditions. If pump starts to sound abnormal, unplug it and check the Impeller by doing the following:
1.Remove the front cover and filter/regulator
(depending on particular pump).
2.Gently pull out the Impeller from the pump body.
3.Rinse the Impeller assembly with clean water. Use an old toothbrush to remove any debris.
4.To prevent damage, do not rest the pump on the impeller or pry against the impeller
5.Once, clean reassemble Pump.
6.NOTE: Make sure the power cord is unplugged before performing any maintenance or cleaning.
Troubleshooting
Follow all safety precautions whenever diagnosing or servicing the tool. Disconnect power supply before service.
68372 Parts List and Assembly Diagram
PLEASE READ THE FOLLOWING CAREFULLY
THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM IN
THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER OR DISTRIBUTOR MAKES ANY
REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS
TO THE PRODUCT, OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT. IN FACT, THE
MANUFACTURER AND/OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD
BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS, AND NOT BY THE BUYER. THE BUYER ASSUMES
ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT
PARTS THERETO, OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO.
Parts List
Assembly Diagram
18
16
13
10 12
8
15
14
7
4
17
Record Product???s Serial Number Here:
Note: If product has no serial number, record month and year of purchase instead.
Note: Some parts are listed and shown for illustration purposes only, and are not available individually as replacement parts.
68393 Parts List and Assembly Diagram
Parts List
Assembly Diagram
68393 Parts List and Assembly Diagram
Parts List
Assembly Diagram
1A
9A
10A
11A
68395 Parts List and Assembly Diagram
Parts List
Assembly Diagram
8
19 18
20
16
68395 Pump Extension Parts List and Assembly Diagram
Parts List
Assembly Diagram
1A
2A
3A
4A
6A
8A
68396 Parts List and Assembly Diagram
Parts List
Assembly Diagram
15
14
10
13
9
11
68
4
1
3
68389 Parts List and Assembly Diagram
Parts List
Assembly Diagram
17
15
12
9 11
14
13
7
4
16
Items 68372, 68393 and 68395: Limited 90 Day Warranty
Harbor Freight Tools Co. makes every effort to assure that its products meet high quality and durability standards, and warrants to the original purchaser that this product is free from defects in materials and workmanship for the period of 90 days from the date of purchase. This warranty does not apply to damage due directly or indirectly, to misuse, abuse, negligence or accidents, repairs or alterations outside our facilities, criminal activity, improper installation, normal wear and tear, or to lack of maintenance. We shall in no event be liable for death, injuries to persons or property, or for incidental, contingent, special or consequential damages arising from the use of our product. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation of exclusion may not apply to you. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS.
To take advantage of this warranty, the product or part must be returned to us with transportation charges prepaid. Proof of purchase date and an explanation of the complaint must accompany the merchandise. If
our inspection verifies the defect, we will either repair or replace the product at our election or we may elect to refund the purchase price if we cannot readily and quickly provide you with a replacement. We will return repaired products at our expense, but if we determine there is no defect, or that the defect resulted from causes not within the scope of our warranty, then you must bear the cost of returning the product.
This warranty gives you specific legal rights and you may also have other rights which vary from state to state.
3491 Mission Oaks Blvd. ??? PO Box 6009 ??? Camarillo, CA 93011 ??? (800)
3491 Mission Oaks Blvd. ??? PO Box 6009 ??? Camarillo, CA 91302 ??? (800)
Page 12For technical questions, please call