Owner???s Manual & Safety Instructions
Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product???s serial number in the back of the manual near the assembly diagram (or month and year of purchase if product has no number). Keep this manual and the receipt in a safe and dry place for future reference.
framing nailer 28?? angle
21?? angle
ITEM 68068
ITEM 68028
When unpacking, make sure that the product is intact and undamaged. If any parts are missing or broken, please call
Copyright?? 2010 by Harbor Freight Tools??. All rights reserved.
No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools.
Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly from the product described herein.
Tools required for assembly and service may not be included.
Read this material before using this product. Failure to do so can result in serious injury.
SAVE THIS MANUAL.
SAFETY
SETUP
OPERATION
Table of Contents
WARNING SYMBOLS AND DEFINITIONS
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
Indicates a hazardous situation which, if not avoided, will result in death or serious injury.
Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
Addresses practices not related to personal injury.
MAINTENANCE
Table A: Symbol Definitions
IMPORTANT SAFETY INSTRUCTIONS
INSTRUCTIONS PERTAINING TO A RISK OF FIRE,
ELECTRIC SHOCK, OR INJURY TO PERSONS
WARNING ??? When using tools, basic precautions should always be followed, including the following:
General
a.To reduce the risks of electric shock, fire, and injury to persons, read all the instructions before using the tool.
SAFETY
Work area
b.Do not operate the tool in explosive atmospheres, such as in the presence of flammable liquids, gases, or dust. The tool is able to create sparks resulting in the ignition of the dust or fumes.
Personal safety
SETUP
a.Stay alert. Watch what you are doing and use common sense when operating the tool. Do not use the tool while tired or under the influence of drugs, alcohol, or medication.
A moment of inattention while operating the tool increases the risk of injury to persons.
b.Dress properly. Do not wear loose clothing or jewelry. Contain long hair. Keep hair, clothing, and gloves away from moving parts. Loose clothes, jewelry, or long hair increases the risk of injury to persons as a result of being caught in moving parts.
c.Avoid unintentional starting. Be sure the trigger is released before connecting to the air supply. Do not carry the tool with your finger on the trigger or connect the tool to the air supply with the trigger pressed.
d.Do not overreach. Keep proper footing and balance at all times.
Proper footing and balance enables better control of the tool in unexpected situations.
e.Use safety equipment.
A dust mask,
f.Always wear eye protection.
Wear
g.Always wear hearing protection when using the tool. Prolonged exposure to high intensity noise is able to
cause hearing loss.
h.Do not attach the hose or tool to your body.
Attach the hose to the structure to reduce the risk of loss of balance if the hose shifts.
i.Always assume that the tool contains fasteners.
Do not point the tool toward yourself or anyone whether it contains fasteners or not.
j.WARNING ??? Do not fire fastener on top of another fastener. This is able to cause the fastener to be deflected and hit someone, or cause the tool to
react and result in a risk of injury to persons.
k.WARNING ??? Remove finger from the trigger when not driving fasteners. Never carry the tool with finger on trigger, the tool is able to fire a fastener.
OPERATION
MAINTENANCE
Tool use and care
SAFETY
SETUP
a.Use clamps or another practical way to secure and support the workpiece to a stable platform.
Holding the work by hand or against the body is unstable and can lead to loss of control.
b.Do not force the tool. Use the correct tool for the application. The correct tool will do the job better and safer at the rate for which the tool is designed.
c.Do not use the tool if the trigger does not turn the tool on or off. Any tool that cannot be controlled with the trigger is dangerous and must not be used until repaired.
d.Disconnect the tool from the air source before making adjustments, doing tool maintenance, clearing jams, touching the safety nosepiece, leaving work area, loading, or unloading the tool. Such precautionary measures reduce the risk of injury to persons.
e.Store the tool when it is idle out of reach of children and other untrained persons.
A tool is dangerous in the hands of untrained users.
f.Maintain the tool with care.
A properly maintained tool reduces the risk of binding and is easier to control.
g.Check for misalignment or binding of moving parts, breakage of parts, and any other condition that affects the tool???s operation. If damaged, have the tool serviced before using. Many accidents
are caused by poorly maintained tools.
There is a risk of bursting if the tool is damaged.
h.Use only accessories that are identified by the manufacturer for the specific tool model. Use of an accessory not intended for use with the specific tool model, increases the risk of injury to persons.
i.Use only those fasteners listed in the Specifications chart of this manual.
Fasteners not identified for use with this tool by the tool manufacturer are able to result in a risk of injury to persons or tool damage when used in this tool.
Service
a.Tool service must be performed only by qualified repair personnel.
b.When servicing a tool, use only identical replacement parts. Use only authorized parts.
Air source
c.Use only the lubricants supplied with the tool or specified by the manufacturer.
a.Never connect to an air source that is b. Never use oxygen, carbon dioxide, combustible
OPERATION
capable of exceeding 200 PSI.
Over pressurizing the tool may cause bursting, abnormal operation, breakage of the tool or serious injury to persons.
Use only clean, dry, regulated compressed air at the rated pressure or within the rated pressure range as marked on the tool. Always verify prior to using the tool that the air source has been adjusted to the rated air pressure or within the rated
gases or any bottled gas as an air source for the tool. Such gases are capable of explosion and serious injury to persons.
MAINTENANCE
SAVE THESE INSTRUCTIONS.
Specific Safety Instructions
1.Operators and others in work area MUST wear
2.Keep fingers away from trigger when not driving fasteners to avoid accidental firing.
3.Choice of triggering method is important. Check manual for triggering options.
4.Always assume the tool contains fasteners.
5.Do not point the tool toward yourself or anyone whether it contains fasteners or not.
6.Do not actuate the tool unless the tool is placed firmly against the workpiece.
7.Respect the tool as a working implement.
8.No horseplay. This tool is not a toy and can be deadly if misused.
9.Do not load the tool with fasteners when any one of the operating controls, such as the Trigger or Safety Nosepiece, is activated.
10.Do not remove, tamper with, or otherwise cause the tool operating controls to become inoperable.
11.Do not operate the tool if any portion of the tool operating controls is inoperable,
disconnected, altered, or not working properly.
12.Disconnect the tool from the air supply when:
a.Unattended.
b.Performing any maintenance or repair.
c.Clearing a jam.
d.Moving the tool to a new location.
13.Do not make any modifications to this tool.
14.Refer to the tool maintenance instructions for detailed information on the proper maintenance of the tool.
15.Fire fasteners into an appropriate work surface only. Do not attempt to fire fasteners into surfaces too hard to penetrate. Do not drive fasteners on top
of other fasteners, or at too steep of an angle. Fasteners can ricochet causing personal injury.
16.Do not fire fasteners too close to the edge of
aworkpiece. They may split the workpiece
and fly free, causing personal injury.
17.Keep clear of the workpiece near the area being fastened. Fasteners may bend sideways during firing, causing them to exit the workpiece at an unexpected point, causing personal injury.
18.Transport tool safely. Always disconnect air supply when moving the tool. Carry the tool by the handle and avoid contact with the trigger.
19.Hold tool away from head and body. During operation the tool may kick back causing injury.
20.Do not fire fasteners into a workpiece that has people, utility lines, or other objects behind or inside it.
21.Keep balance while using this tool.
Keep area below clear if working in an elevated location, and secure air hose to prevent falls from bystanders accidentally pulling on it.
22.Obey the manual for the air compressor used to power this tool.
23.Install an
24.Do not engrave or stamp anything into the housing to avoid weakening it.
25.WARNING: Some dust created by power sanding, sawing, grinding, drilling, and other construction activities, contains chemicals known [to the State of California] to cause cancer, birth defects or other reproductive harm. Some examples of these chemicals are:
???Lead from
???Crystalline silica from bricks and cement or
other masonry products
??? Arsenic and chromium from chemically treated lumber
Your risk from these exposures varies, depending on how often you do this type of work.
To reduce your exposure to these chemicals: work in a well ventilated area, and work with approved safety equipment, such as those dust masks that are specially designed to filter out microscopic particles. (California Health & Safety Code ?? 25249.5, et seq.) WARNING: The brass components of
this product contain lead, a chemical known to the State of California to cause birth defects (or other reproductive harm).
(California Health & Safety code ?? 25249.5, et seq.)
26.The warnings and precautions discussed in this manual cannot cover all possible conditions and situations that may occur. It must be understood by the operator that common sense and caution are factors which cannot be built into this product, but must be supplied by the operator.
SAFETY
SETUP
OPERATION
MAINTENANCE
Vibration Precautions
SAFETY
This tool vibrates during use.
Repeated or long???term exposure to vibration may cause temporary or permanent physical injury, particularly to the hands, arms and shoulders. To reduce the risk of
1.Anyone using vibrating tools regularly or for an extended period should first be examined by a doctor and then have regular medical
If you feel any symptoms related to vibration (such as tingling, numbness, and white or blue fingers), seek medical advice as soon as possible.
2.Do not smoke during use. Nicotine reduces the blood supply to the hands and fingers, increasing the risk of
3.Wear suitable gloves to reduce the vibration effects on the user.
4.Use tools with the lowest vibration when there is a choice between different processes.
5.Include
6.Grip tool as lightly as possible (while still keeping safe control of it). Let the tool do the work.
7.To reduce vibration, maintain tool as explained in this manual. If abnormal vibration occurs, stop immediately.
SETUP
OPERATION
Components and Controls
MAINTENANCE
Trigger
Depth
Knob
Magazine
Safety Nosepiece: Also called the workpiece contact, the Safety Nosepiece helps prevent the tool from firing unless it is pressed against an object.
Depth Knob: This controls the depth that fasteners penetrate. Most applications call for the fastener heads to be flush with the surface or slightly sunken.
Turn the knob left to fire nails deeper. Turn the knob right to fire nails shallower.
REV 12a
Initial Tool Set Up/Assembly
Read the ENTIRE IMPORTANT SAFETY INFORMATION section at the beginning of this manual including all text under subheadings therein before set up or use of this product.
Note: For additional information regarding the parts listed in the following pages, refer to the Assembly Diagram near the end of this manual.
Air Supply
TO PREVENT EXPLOSION:
Use only clean, dry, regulated, compressed air to power this tool. Do not use oxygen, carbon dioxide, combustible gases, or any other bottled gas as a power source for this tool.
SAFETY
1.Incorporate a filter, regulator with pressure gauge, oiler,
ball valve is an important safety device because it controls the air supply even if the air hose
is ruptured. The shutoff valve should be a ball valve because it can be closed quickly.
Note: If an automatic oiler system is not used, add a few drops of Pneumatic Tool Oil into the airline connection before operation.
Add a few more drops after each hour of continual use.
Note: This air tool may be shipped with a protective plug covering the air inlet. Remove this plug before set up.
2.Attach an air hose to the compressor???s air outlet. Connect the air hose to the air inlet of the tool. Other components, such as a coupler plug
and quick coupler, will make operation more efficient, but are not required.
WARNING! TO PREVENT SERIOUS INJURY
FROM ACCIDENTAL OPERATION:
Do not install a female quick coupler on the tool.
Such a coupler contains an air valve that will allow the air tool to retain pressure and operate accidentally after the air supply is disconnected.
Note: Air flow, and therefore tool performance,
can be hindered by undersized air supply components.
3.The air hose must be long enough to reach the work area with enough extra length to allow free movement while working.
4.Release the tool???s trigger.
5.Close the
6.Turn on the air compressor according to the manufacturer???s directions and allow it to build up pressure until it cycles off.
7.Adjust the air compressor???s output regulator so that the air output is enough to properly power the tool, but the output will not exceed the tool???s maximum air pressure at any time.
Adjust the pressure gradually, while checking the air output gauge to set the right pressure range.
8.The air pressure setting must not exceed job site regulations/restrictions. The air pressure setting must not exceed 90 PSI when being used with work pieces that have a thickness of less than
9.Inspect the air connections for leaks. Repair any leaks found.
10.If the tool will not be used at this time, turn off and detach the air supply, safely discharge any residual air pressure, and release the trigger to prevent accidental operation.
Note: Residual air pressure should not be present after the tool is disconnected from the air supply. However, it is a good safety measure to attempt to discharge the tool in a safe fashion after disconnecting to ensure that the tool is disconnected and unpowered.
SETUP
OPERATION
MAINTENANCE
8 Page
68028 Item 68068
Figure A: Portable Air Supply Setup
68028 Item 68068
9 Page
SAFETY
Operating Instructions
Read the ENTIRE IMPORTANT SAFETY INFORMATION section at the beginning of this manual including all text under subheadings therein before set up or use of this product.
Inspect tool before use, looking for damaged, loose, and missing parts.
If any problems are found, do not use tool until repaired.
Work Piece and Work Area Set Up
1.Designate a work area that is clean and well???lit. The work area must not allow access by children or pets to prevent distraction and injury.
2.Route the air hose along a safe route to reach the work area without creating a tripping hazard or exposing the air hose to possible damage. The air hose must be long enough to reach
the work area with enough extra length to allow free movement while working.
3.Secure loose workpieces using a vise or clamps (not included) to prevent movement while working.
4.There must not be hazardous objects
(such as utility lines or foreign objects) nearby that will present a hazard while working.
SETUP
Single Sequential Safety Trip Mechanism Definition
This tool has a single sequential safety trip mechanism, which is designed to prevent inadvertent firing. The tool should only fire if the Safety Nosepiece is pressed against the workpiece prior to
pulling the Trigger. It should only fire again if the trigger is released and squeezed again. The Tool should not fire if the Safety Nosepiece is not pressed against an object.
Single Sequential Safety Trip Mechanism Testing Procedure
TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION:
Empty the tool before this procedure. Point the tool at a piece of scrap wood when testing.
OPERATION
MAINTENANCE
1.Disconnect the tool from the air supply.
2.Empty the magazine of fasteners.
3.Check that the Trigger and the Safety Nosepiece move freely, without sticking.
4.Connect the air supply to the tool and set within the Operating Air Pressure indicated on the Specification chart.
5.Test the tool by pressing the Safety Nosepiece against the workpiece without pulling the Trigger.
The tool must not cycle (fire). If it cycles (fires), stop immediately and have it repaired
by a qualified service technician.
6.Hold the tool away, or off of the workpiece.
The Safety Nosepiece should return to its original position. Squeeze the Trigger. The tool must not cycle (fire). If it cycles (fires), stop immediately and take the tool to a qualified service technician.
7.Press the Safety Nosepiece against the workpiece and squeeze the Trigger. The tool must
cycle (fire) only once. Release the trigger and squeeze it again. The tool must cycle (fire) again only once. With the Trigger held, carefully lift the tool and press it against the workpiece again. The tool must not cycle (fire). If it fails to act in the manner explained in bold, have it repaired by a qualified service technician.
Loading the Tool
TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION, BEFORE LOADING:
???Wear
Other people in the work area must also wear
???Release the trigger.
???Detach the air supply.
???Attempt to fire the Tool into a piece of scrap wood to ensure that it is disconnected and is incapable of firing any fasteners.
1.Pull Feeder Shoe all the way to the rear of Magazine. 3. When loading nails, make sure the
General Operating Instructions
SAFETY
1.Before each use, test the tool as directed in the prior section.
2.If an automatic oiler is not used, add a few drops of Pneumatic Tool Oil to the airline connection before use. Add a few drops more after each hour of continual use.
3.Attach the Nailer to the air supply at the air inlet. Start your compressor and check the pressure making sure it is set at the recommended
4.Adjust Exhaust Cover to direct as desired.
5.To fire a nail, place the nose of the Nailer on the workpiece. The Nailer should not fire if the Safety is not depressed. Once the Safety is depressed, gently and briefly squeeze the Trigger once to fire one nail. Release the Trigger. Do not fire repeatedly; nails could bounce off on one another, damaging the workpiece or causing personal injury.
6.If nails are not being driven flush, turn the Depth Knob to the left.
7.Move the Nailer to another spot on the workpiece and squeeze the Trigger again to fire another nail. Continue firing nails as needed.
8.If the tool requires more force to accomplish the task, verify that the tool receives sufficient, unobstructed airflow (CFM) and increase the pressure (PSI) output of the regulator up to the maximum air pressure rating of this tool.
CAUTION! TO PREVENT INJURY FROM TOOL OR
ACCESSORY FAILURE: Do not exceed the tool???s
maximum air pressure rating.
If the tool still does not have sufficient force at maximum pressure and sufficient airflow, then a larger tool may be required.
9.After use, to prevent accidents:
a.Release the trigger.
b.Detach the air supply.
c.Attempt to fire the Tool into a piece of scrap wood to ensure that it is disconnected
and is incapable of firing any fasteners.
d.Release the trigger again.
e.Clean external surfaces with clean, dry cloth.
f.Store indoors out of children???s reach.
SETUP
OPERATION
MAINTENANCE
SAFETY
SETUP
Procedures not specifically explained in this manual must be performed only by a qualified technician.
TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION,
BEFORE ANY MAINTENANCE OR REPAIRS ARE DONE (including clearing jams):
???Wear
Other people in the work area must also wear
???Release the trigger.
???Detach the air supply.
???Attempt to fire the Tool into a piece of scrap wood to ensure that it is disconnected and is incapable of firing any fasteners.
???Empty the magazine and leave it open during service.
The Magazine is spring???loaded and may cause parts or a fastener to fly out of the Tool.
TO PREVENT SERIOUS INJURY FROM TOOL FAILURE: Do not use damaged equipment.
If abnormal noise, vibration, or leaking air is detected, have the problem corrected before further use.
TO PREVENT EXPLOSION: Lubricate only with specified lubricants. Lubricate the air inlet using only pneumatic tool oil. Lubricate the internal mechanism using only white lithium grease.
Other lubricants may damage the mechanism and may be highly flammable, causing an explosion.
Note: These procedures are in addition to the regular checks and maintenance explained as part of the regular operation of the
1.BEFORE EACH USE, inspect the general condition of the tool. Check for:
???loose hardware or housing,
???misalignment or binding of moving parts,
???cracked or broken parts, and
???any other condition that may affect its safe operation.
2.Daily - Air Supply Maintenance:
Every day, perform maintenance on the air supply according to the component manufacturers' instructions. Maintain the lubricator's oil level. Drain the moisture filter regularly.
Performing routine maintenance on the air supply will allow the tool to operate more safely and will also reduce wear on the tool.
OPERATION
Clearing Jams
TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION,
BEFORE ANY MAINTENANCE OR REPAIRS ARE DONE (including clearing jams):
???Wear
Other people in the work area must also wear
???Release the trigger.
???Detach the air supply.
???Attempt to fire the Tool into a piece of scrap wood to ensure that it is disconnected and is incapable of firing any fasteners.
???Empty the magazine and leave it open during service.
The Magazine is spring???loaded and may cause parts or a fastener to fly out of the Tool.
MAINTENANCE
1.If a fastener is jammed in the discharge area, remove it with pliers.
2.If a fastener is jammed in the magazine, pull the Pusher all the way back to the engaged position. Use a screwdriver to release the jammed fastener by probing the openings in the magazine.
3.Pull out the jammed fastener and the remainder of the fastener strip from the magazine.
Dispose of the remaining fastener strip;
it is likely bent or damaged and may cause repeated jamming or damage to the tool if reused.
4.If the jam cannot be cleared using the method above, have the tool serviced by a qualified technician.
Troubleshooting
Follow all safety precautions whenever diagnosing or servicing the tool. Disconnect air supply before service.
SAFETY
SETUP
OPERATION
PLEASE READ THE FOLLOWING CAREFULLY
THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM
IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER OR DISTRIBUTOR
MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS
QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT, OR THAT HE OR SHE IS QUALIFIED TO REPLACE
ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER AND/OR DISTRIBUTOR EXPRESSLY
STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND
LICENSED TECHNICIANS, AND NOT BY THE BUYER. THE BUYER ASSUMES ALL RISK AND LIABILITY
ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS
THERETO, OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO.
MAINTENANCE
Parts List and Diagram
Parts List
SAFETY
SETUP
OPERATION
MAINTENANCE
Record Product???s Serial Number Here:
Note: If product has no serial number, record month and year of purchase instead.
Note: Some parts are listed and shown for illustration purposes only, and are not available individually as replacement parts.
Assembly Diagram
SAFETY
SETUP
OPERATION
MAINTENANCE
Limited 90 Day Warranty
Harbor Freight Tools Co. makes every effort to assure that its products meet high quality and durability standards, and warrants to the original purchaser that this product is free from defects in materials and workmanship for the period of 90 days from the date of purchase. This warranty does not apply to damage due directly or indirectly,
to misuse, abuse, negligence or accidents, repairs or alterations outside our facilities, criminal activity, improper installation, normal wear and tear, or to lack of maintenance. We shall in no event be liable for death, injuries to persons or property, or for incidental, contingent, special or consequential damages arising from the use of our product. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation of exclusion may not apply to you. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS.
To take advantage of this warranty, the product or part must be returned to us with transportation charges prepaid. Proof of purchase date and an explanation of the complaint must accompany the merchandise. If our inspection verifies the defect, we will either repair or replace the product at our election or we may elect to refund the purchase price if we cannot readily and quickly provide you with a replacement. We will return repaired products at our expense, but if we determine there is no defect, or that the defect resulted from causes not within the scope of our warranty, then you must bear the cost of returning the product.
This warranty gives you specific legal rights and you may also have other rights which vary from state to state.
3491 Mission Oaks Blvd. ??? PO Box 6009 ??? Camarillo, CA 93011 ??? (800)