QuickSpecs

HP StorageWorks 2000sa G2 Modular Smart Array

Overview

The HP StorageWorks 2000sa G2 Modular Smart Array is a 3Gb SAS direct attach, external shared storage solution that helps customers easily transition from direct attached to centralized storage. It allows departmental and small to medium businesses customers to grow capacity as demands increase up to 29.7 TB SAS or 60 TB SATA, and supporting up to 64 hosts

With up to 511 LUNs and LUN sizes up to 16 TB, the MSA2000sa G2 gives maximum configuration flexibility. The MSA2000sa G2 allows mixing of enterprise-class, dual-ported SAS drives and archival-class SATA drives, and supports both Large Form Factor and Small Form Factor drives. The optional HP StorageWorks 2000 Modular Smart Array Snapshot Software offers increased data protection. The MSA2000sa G2 can be configured with a single controller for a low initial price with future expansion, or with dual controller for situations that require higher availability and performance for the most demanding entry-level situations.

What's New

New SAS controller with four SAS host ports

Supports up to 8 hosts with SAS direct connect and 64 hosts (BladeSystem servers) using 3Gb SAS BL switch Support for Small Form Factor (SFF) SAS and SATA drives, common with ProLiant

Support for attachment of THREE dual I/O MSA70 SFF JBODs (total ninety-nine SFF drives)

Increased support to FOUR MSA2000 LFF disk enclosures with the MSA2012 Chassis (sixty LFF drives) Support for new Small Form Factor 300 GB SAS drive - doubling the SFF SAS capacity

Increased optional snapshot capability to 255 snaps

Additional LUN support up to 511 total volumes in a Dual Controller system Availability of a carrier grade NEBS-certified DC-powered MSA2024 SFF chassis

HP StorageWorks 2024 G2 Modular Smart Array

HP StorageWorks 2012 G2 Modular Smart Array

QuickSpecs

HP StorageWorks 2000sa G2 Modular Smart Array

Models

Models

HP StorageWorks

2000sa G2 Modular

Smart Array

Related Items

MSA2324sa G2 DL380

G6 Package Cluster

MSA2000sa Switch

Bundle

Controller-less CHASSIS & MSA2300sa G2 Controller

HP StorageWorks 2012 Modular Smart Array 3.5-in Drive Bay Chassis (LFF) (Will accept one or two controllers or Disk Enclosure I/O modules)

HP StorageWorks 2024 Modular Smart Array 2.5-in Drive Bay Chassis (SFF) (Will accept one or two controllers)

HP StorageWorks 2300sa G2 Modular Smart Array Controller

Disk Enclosures

HP StorageWorks MSA2000 Single I/O 3.5-inch 12 LFF Drive Enclosure (w/ two .6m SAS to SAS cables) Used with single controller array head

HP StorageWorks MSA2000 Dual I/O 3.5-inch inch 12 LFF Drive Enclosure (w/ two .6m SAS to SAS cables) Used with dual controller array head

HP StorageWorks MSA2000 Drive Enclosure I/O Module (no cable included)

HP StorageWorks MSA70 2.5-inch 25 SFF Drive Enclosure 2.5 in Drive Enclosure

(single I/O, single domain) (w/one .5m miniSAS to miniSAS cable)

HP StorageWorks Dual Domain I/O Module for MSA70 enclosure (upgrades MSA70 to dual domain) (w/ one .5m miniSAS to miniSAS cable)

Configured Units

HP StorageWorks 2312sa G2 Dual Controller Modular Smart Array (LFF)

HP StorageWorks 2324sa G2 Dual Controller Modular Smart Array (SFF)

Controller-less Chassis: DC-powered units

HP StorageWorks 2012 Modular Smart Array 3.5-in Drive Bay DC-power Chassis (LFF) (can add one or two MSA2300sa G2 controllers or MSA2000 JBOD I/O modules)

HP StorageWorks 2024 Modular Smart Array 2.5-in Drive Bay DC-power Chassis (SFF) (can add one or two MSA2300sa G2 controllers. No MSA2000 JBOD I/O module support)

Controller-less Carrier Grade Chassis

HP StorageWorks 2024 Modular Smart Array 2.5-in Drive Bay Carrier-Grade Chassis (SFF)

Related Option

HP StorageWorks 2000sa Modular Smart Array Controller (limited use) (for use only with an AJ948A LFF chassis for those needing to configure an older MSA2012sa. Only supports older features, functionalities. No SFF or MSA70 JBOD support, max 48 LFF drives, max 64 snaps)

HP StorageWorks 2324sa G2 Modular Smart Array DL380 G6 Package Cluster NOTE: The HP MSA2324sa G2 DL380 G6 Package Cluster Bundle contains the following components:

One MSA2324sa G2 Dual-controller array; Two DL380 G6 Servers

Four HBAs

Four SAS cables Snapshot software 8 LTU

(NOTE: This bundle is available worldwide except APJ and Brazil)

HP StorageWorks 2000sa Modular Smart Array 3Gb SAS BL Switch Bundle

NOTE: The HP MSA2000sa 3Gb SAS BL Switch Bundle contains the following components:

HP MSA2012sa DC Modular Smart Array (Qty 1)

AJ948A

AJ949A

AJ808A

AJ749A

AJ750A

AJ751A

418800-B21

AG779A

AJ805A

AJ807A

AJ950A

AJ951A

AM337A

AJ754A

AP813A

AP716A

QuickSpecs

HP StorageWorks 2000sa G2 Modular Smart Array

Models

HP 3Gb SAS BL Switches (Qty 2)

HP mini-SAS 2M Cable (Qty 4)

Blade Mezzanine

Module

1.The SAS Switch is supported only in the HP c-Class Enclosures (C7000 & C3000)

2.The switch is placed into an interconnect bay in the back of the c-Class Enclosure chassis. C7000 chassis has 6 interconnect bays for switches & C3000 chassis has 3 interconnect bays for switches, however for this solution we will only support the use of 4 interconnect bays in the C7000 and 2 interconnect bays in the C3000.

3.(2) SAS Switches are required in the same c-Class enclosure interconnect bay row.

4.For the C3000 enclosure, the SAS Switch can only be placed into interconnect bays (3 and 4)

5.For the C7000 enclosure, the SAS Switch can only be placed into interconnect bays (3 and 4), or (5 and 6) or (7 and 8). The preferred interconnect bays are (5 and 6) then (7 and 8).

6.For the C3000 enclosure, using a server's mezzanine slot 1 along with enclosure interconnect bay 2 is not supported.

1.A half height blade server must have a P700m (508226-B21 or 507925- B21) installed in server mezzanine slot 1 or mezzanine slot 2. The preferred mezzanine slot is slot 2.

2.A full height blade server must have a P700m 508226-B21 or 507925- B21) installed in server mezzanine slot 1, mezzanine slot 2 or mezzanine slot 3. The preferred mezzanine slot is slot 2.

3.A double density blade server must have a P700m (508226-B21 or 507925-B21) installed in server mezzanine slot 2 of each server. 4 SAS Switches, in interconnect bays 5, 6, 7 and 8, must also be included in this configuration.

QuickSpecs

HP StorageWorks 2000sa G2 Modular Smart Array

Features and Benefits

Key Hardware Features

Highly efficient consolidation and sharing of storage geared to departmental and small to medium business requirements

Cost efficient plus high-availability choices

Flexibility in drives: LFF MSA2 3.5-inch or HP ProLiant SFF 2.5-inch drives Enterprise-class SAS or archival-class SATA drives as the need and budget dictates Dual-ported SAS drives for enterprise needs

Large capacity SATA drives for inexpensive archival storage

Able to mix SAS and SATA drives within the same drive enclosure Choose either single or dual controller array models to fit the budget

Choice of low cost single I/O or high-availability dual I/O drive enclosure models

Customer Benefits

The HP StorageWorks 2000 Modular Smart Array family manages growing storage requirements across multiple HP ProLiant servers for customers who need a centralized dedicated storage solution for applications. Shared storage allows for controlled, cost-effective growth and increased protection of data.

Its ease of management allows a department or small company to effectively handle growing storage requirements with a minimum of complexity.

The MSA2000sa G2 extends the benefits of shared storage resources to first time implementers on a tight budget Depending on the model chosen, the modular design allows the user to start relatively small but supports future growth to hundreds of users and up to 27 TB of LFF SAS or 60 TB of LFF SATA storage, or 29.7 TB of SFF SAS or 24.7 TB of SFF SATA storage.

The optional controller-based snapshot and clone capability as part of the MSA2000 family allows the smaller departmental user or company to implement functionality once only available to much larger firms with expensive arrays.

QuickSpecs

HP StorageWorks 2000sa G2 Modular Smart Array

At a Glance

HP MSA2000sa G2 At a Glance:

High performance Modular Smart Array controller with four 3Gb SAS ports per controller Single and dual controller capability

1 GB transportable cache per controller - battery-free cache backup with super capacitors and compact flash 511 LUNs with 16TB LUNs supported

2U rack mount chassis combining both the controller and disk shelf

Twelve 3.5 inch dual-ported SAS or SATA MSA2000-specific drives (supports mixing of drive types in a single shelf) Twenty-four 2.5 inch dual-ported SAS or SATA ProLiant drives (also supports mixing of drive types in a single shelf) Support expansion to 4 additional enclosures & total of 48 disk drives

Supports expansion to 3 additional SFF enclosures (MSA70) for a maximum total of 99 SFF disks Redundant power supplies and fans are standard

RAID levels 0, 1, 3, 5, 6, 10, 50 Non-disruptive on-line controller code upgrade

Heterogeneous support for 32-bit and 64-bit Windows, Red Hat and SuSE Linux

Windows Server 2008 x64 Hyper-V, VMware, RedHat Enterprise Linux Virtualization, and Citrix XenServer Qualified and certified for Windows, Linux and Solaris clustering

Optional controller-based snapshot and clone functionality

QuickSpecs

HP StorageWorks 2000sa G2 Modular Smart Array

Family Information

*maximum available storage capacity depends on the RAID level being implemented, and is based on maximum number of LUNs and LUN size

** Supports up to 8 hosts with SAS direct connect and 64 hosts (BladeSystem servers) using 3Gb SAS BL switch

QuickSpecs

HP StorageWorks 2000sa G2 Modular Smart Array

Family Information

QuickSpecs

HP StorageWorks 2000sa G2 Modular Smart Array

Family Information

RAID 0, 1, 3, 5, 6, 10, 50 In addition to the usual RAID levels, the MSA2000 family features several important additional levels. RAID 6 is the highest level of RAID protection. It allocates two sets of parity data across drives and allows simultaneous write operations. It can withstand two simultaneous drive failures without downtime or data loss. RAID 10 is mirroring and striping without parity. It is the most popular of the multiple RAID levels, allowing large arrays with high performance in most cases and superior fault tolerance. RAID 50 combines the block striping and parity of RAID 5 with the straight block striping of RAID 0, yielding higher performance than RAID 5 through the addition of RAID 0, particularly during writes.

QuickSpecs

HP StorageWorks 2000sa G2 Modular Smart Array

Family Information

QuickSpecs

HP StorageWorks 2000sa G2 Modular Smart Array

Family Information

QuickSpecs

HP StorageWorks 2000sa G2 Modular Smart Array

Optional Software

Optional Software

Snap or clone data to test the performance of a software application on 'offline' production data

Snap or clone data to test how a software patch or enhancement will function on 'offline; production data

Path Failover (MPIO) MPIO Basic Failover for Windows provides a single multi-path solution for HP StorageWorks MSA2000sa G2 Modular Smart Array on HP ProLiant servers by providing basic path failover. Supports Windows 2008, Windows 2003, Windows 2003 R2, and Windows 2003 X64 operating systems.

HP MPIO Full DSM for the MSA2000sa

Microsoft Windows 2008: Microsoft MPIO is bundled with Windows Server 2008 and must be installed as an operating system feature.

Failover support for Linux is with Device Mapper 4.0 or higher HP-UX 11iv3 Native Multipathing for Mass Storage

Sun Solaris native MPxIO

HP StorageWorks HP StorageWorks Storage Mirroring Software provides host-based, continuous replication for Storage Mirroring customers seeking a low-cost alternative to fabric or array-based replication. Patented replication

and failover technology continuously captures byte-level data changes as they happen and replicates those changes to one or more target servers at any location without geographic limitations. By replicating only the bytes that change, Storage Mirroring Software uses the absolute minimum bandwidth on your existing LAN or WAN to replicate your data. Storage Mirroring also provides server failover where a production server can automatically be 'replaced' by the storage mirroring server in the event of failure. Couple Storage Mirroring with MSA2000 Snapshots and/or Volume Copy to achieve an Enterprise class data protection strategy creating different data recovery points using continuous data protection with Storage Mirroring and point- in-time data protection with Snapshots and/or Volume Copy.

Storage Mirroring Software supports:

Any DAS, NAS, and SAN storage device.

Any Windows ProLiant server including all ML, DL, and BL platforms

Many Windows platforms including Windows Server 2000, Windows Server 2003, Windows

QuickSpecs

HP StorageWorks 2000sa G2 Modular Smart Array

Optional Software

Server 2003 R2, Windows Storage Server 2003, Windows Storage Server 2003 R2, 64-bit

Windows, and Windows on Itanium

For more information visit: http://h18006.www1.hp.com/products/storage/software/sm/index.html

QuickSpecs

HP StorageWorks 2000sa G2 Modular Smart Array

Service and Support, HP Care Pack, and Warranty Information

Enclosures, Hard drives, and Options for the MSA2000sa G2 carry their own warranty. Refer to HP's Limited Warranty Statement for more information.

The MSA2000sa has been designed with customer self repairable parts to minimize repair time and provide greater flexibility in performing defective parts replacement. Please refer to HP's limited warranty Statement and parts replacement instructions for further details.

http://h18006.www1.hp.com/products/storageworks/warranty.html

Products included in various Kits carry their own individual warranties.

NOTE: The warranty of the hard drive options purchased with the MSA2000sa product is different for SAS hard drives versus SATA hard drives. SAS hard drive options have a three year warranty and SATA hard drives options have a one year warranty. Reference HP's communication for further details: http://www.hp.com go to search, enter CN0089W

HP Care Pack Services. Scalable, Flexible, Dependable. Like your storage.

Your storage is evolving. Get scalable support that evolves with it. HP Care Pack Services is an easy-to-buy, easy-to-use portfolio of packaged services covering your lifecycle needs. You can rely on our highly skilled, HP certified professionals to offer a breadth of expertise across leading storage technologies, and work side by side with you for optimal results. Partner with HP Technology Services to boost availability and avoid costly downtime by mitigating technology-related business risks. To help take the worry out of deploying, supporting and managing your storage technologies, we've designed a portfolio of service options that are as flexible, scalable and affordable as our storage.

Protect your business beyond the warranty

Standard warranty protects against product defects and some causes of downtime. HP Care Pack Services helps you proactively guard against unplanned downtime which can reduce your productivity and profitability. By using a standard approach to warranty uplifts, such as HP Care Pack Services, customers can be certain of consistency of operations for both mission-critical and standard business computing.

Extending warranties with HP Care Pack Services

The key to normalizing the warranty of combined solutions-is making service uplift simple: HP Care Pack Services. This portfolio of predefined packages, extending across the entire IT lifecycle, offering consulting, education, technical support, optimization, risk assessment, and more. It's entirely flexible allowing customers to extend the cover to the precise level of support required. Customer's standard hardware warranty, for example, can be upgraded to next-business-day response, to same-day coverage, or even to a committed six-hour call-to-repair service available 24 hours every day of the week.

Provide consistent, predictable levels of support across your entire department or business

Give you direct access to proven technical and problem-solving expertise Offer a choice of response-time and repair-time commitments

Are available whenever and wherever you do business

For many products, post-warranty HP Care Pack Services are available when your original warranty has expired. Choose the support levels that meet your business requirements, from basic to mission-critical. In the new world of business technology, when your technology has to work for your business to work, who can you trust to make your technology work? HP Technology Services, the trusted business technology experts who manage your technology in action, because when technology works, business works. http://www.hp.com/hps/storage

NOTE: Care Pack Services availability may vary by product and country.

QuickSpecs

HP StorageWorks 2000sa G2 Modular Smart Array

Service and Support, HP Care Pack, and Warranty Information

QuickSpecs

HP StorageWorks 2000sa G2 Modular Smart Array

Service and Support, HP Care Pack, and Warranty Information

Services that will enhance the user experience in many product deployments.

Contact your HP sales rep or Channel Partner for assistance

Contact your HP sales rep or Channel Partner for assistance

QuickSpecs

HP StorageWorks 2000sa G2 Modular Smart Array

Service and Support, HP Care Pack, and Warranty Information

HP Remote Support Pack enhances HP Systems Insight Manager with intelligent event diagnosis plus the automatic submission of hardware event notifications securely to HP support, including acknowledgment and status returns. It adds remote configuration collections to allow the delivery of assessment and proactive services for your SAN storage and HP-UX environments.

QuickSpecs

HP StorageWorks 2000sa G2 Modular Smart Array

Configuration Information

QuickSpecs

HP StorageWorks 2000sa G2 Modular Smart Array

Configuration Information

Step 1 - MSA2000sa G2- Base Configuration

There are two array-head chassis - one with twelve 3.5-inch large form factor bays, the other with twenty-four 2.5-inch small form factor drive bays. For additional twelve additional drive bays purchase an MSA2000 3.5-inch Disk Enclosure. You may attach a total of four MSA2000 Drive Enclosures for a total of sixty LFF drives. For 25 additional SFF drive bays purchase an MSA70 JBOD with the 2nd I/O module. You may attach a total of three MSA70 JBODs for a total of ninety- nine SFF drives. Single controller arrays support Single I/O Disk Enclosures; dual controller arrays support Dual I/O Disk Enclosures.

Step 2 - Options

Select each option with quantities specified.

Step 2a - Options

Step 2b - Choose Supported Options For SAS HBA

Step 2c - MSA2 SAS and SATA Drive Options

NOTE: SATA drives are designed for archival or reference data. They should not be used in a heavy or intense I/O environment. Those situations require the use of enterprise-class SAS drives. MSA2 3.5-inch drives are for use only with MSA2000 products.

QuickSpecs

HP StorageWorks 2000sa G2 Modular Smart Array

Configuration Information

Step 2d - Drive Enclosure Options

Should you want a drive enclosure, the model you choose depends on which array model it attaches to. If it is a single controller array, then choose the JBOD designated as "Single I/O". If it is attaching to a dual controller array then choose the "Dual I/O" JBOD

Step 2e - SAS Cable Options

QuickSpecs

HP StorageWorks 2000sa G2 Modular Smart Array

Configuration Information

Step 3 - Other MSA2000sa Options

Step 4 - Choose Rack Options

Select each required option with quantities specified.

Rack Cabinet, Customer Assembled

QuickSpecs

HP StorageWorks 2000sa G2 Modular Smart Array

Configuration Information

Configure to Order (CTO) Program Information

HP introduces the new Configure to Order program for the MSA2000 family The MSA2000 models and options may or may not be factory installed in a rack with add-on controllers, switches, hubs, MSA2000 disk enclosures and hard drives. The MSA2000 arrays may be integrated with ProLiant servers or as standalone storage.

Orders to be shipped through the CTO process must have a minimum of two drives ordered per controller.

SAS Drives (SFF 2.5- inch)

Makes the standard MSA70 (above) into a dual I/O, dual domain JBOD NOTE: The I/O Module is a field upgradeable Option Kit the addition of which in the MSA70 will allow dual domain capability providing higher level of redundancy and reliability

SATA Drives (SFF 2.5- inch)

NOTE: Only Dual Port (DP) drives will work as dual-port in a Dual Domain environment. Dual Domain environment requires the HP StorageWorks Dual Domain I/O Module Option (# AG779A).

QuickSpecs

HP StorageWorks 2000sa G2 Modular Smart Array

Configuration Information

NOTE: SATA drives for the MSA70 are not dual port (DP) drives.

NOTE: Go to the HP Hard Drive Compatibility table for complete drive compatibility information (http://www.hp.com/products/harddiskdrives). Using hard drives in unsupported configurations will result in voiding the warranty and could result in damage to the drive and/or loss of data

QuickSpecs

HP StorageWorks 2000sa G2 Modular Smart Array

Technical Specifications

QuickSpecs

HP StorageWorks 2000sa G2 Modular Smart Array

Technical Specifications

?? Copyright 2009 Hewlett-Packard Development Company, L.P.

The information contained herein is subject to change without notice.

Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Intel is a US registered trademark of Intel Corporation. Unix is a registered trademark of The Open Group.

The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.