QuickSpecs
HP StorageWorks 2000sa G2 Modular Smart Array
Overview
The HP StorageWorks 2000sa G2 Modular Smart Array is a 3Gb SAS direct attach, external shared storage solution that helps customers easily transition from direct attached to centralized storage. It allows departmental and small to medium businesses customers to grow capacity as demands increase up to 29.7 TB SAS or 60 TB SATA, and supporting up to 64 hosts
With up to 511 LUNs and LUN sizes up to 16 TB, the MSA2000sa G2 gives maximum configuration flexibility. The MSA2000sa G2 allows mixing of
What's New
New SAS controller with four SAS host ports
Supports up to 8 hosts with SAS direct connect and 64 hosts (BladeSystem servers) using 3Gb SAS BL switch Support for Small Form Factor (SFF) SAS and SATA drives, common with ProLiant
Support for attachment of THREE dual I/O MSA70 SFF JBODs (total
Increased support to FOUR MSA2000 LFF disk enclosures with the MSA2012 Chassis (sixty LFF drives) Support for new Small Form Factor 300 GB SAS drive - doubling the SFF SAS capacity
Increased optional snapshot capability to 255 snaps
Additional LUN support up to 511 total volumes in a Dual Controller system Availability of a carrier grade
HP StorageWorks 2024 G2 Modular Smart Array
HP StorageWorks 2012 G2 Modular Smart Array
QuickSpecs
HP StorageWorks 2000sa G2 Modular Smart Array
Models
Models
HP StorageWorks
2000sa G2 Modular
Smart Array
Related Items
MSA2324sa G2 DL380
G6 Package Cluster
MSA2000sa Switch
Bundle
HP StorageWorks 2012 Modular Smart Array
HP StorageWorks 2024 Modular Smart Array
HP StorageWorks 2300sa G2 Modular Smart Array Controller
Disk Enclosures
HP StorageWorks MSA2000 Single I/O
HP StorageWorks MSA2000 Dual I/O
HP StorageWorks MSA2000 Drive Enclosure I/O Module (no cable included)
HP StorageWorks MSA70
(single I/O, single domain) (w/one .5m miniSAS to miniSAS cable)
HP StorageWorks Dual Domain I/O Module for MSA70 enclosure (upgrades MSA70 to dual domain) (w/ one .5m miniSAS to miniSAS cable)
Configured Units
HP StorageWorks 2312sa G2 Dual Controller Modular Smart Array (LFF)
HP StorageWorks 2324sa G2 Dual Controller Modular Smart Array (SFF)
HP StorageWorks 2012 Modular Smart Array
HP StorageWorks 2024 Modular Smart Array
HP StorageWorks 2024 Modular Smart Array
Related Option
HP StorageWorks 2000sa Modular Smart Array Controller (limited use) (for use only with an AJ948A LFF chassis for those needing to configure an older MSA2012sa. Only supports older features, functionalities. No SFF or MSA70 JBOD support, max 48 LFF drives, max 64 snaps)
HP StorageWorks 2324sa G2 Modular Smart Array DL380 G6 Package Cluster NOTE: The HP MSA2324sa G2 DL380 G6 Package Cluster Bundle contains the following components:
One MSA2324sa G2
Four HBAs
Four SAS cables Snapshot software 8 LTU
(NOTE: This bundle is available worldwide except APJ and Brazil)
HP StorageWorks 2000sa Modular Smart Array 3Gb SAS BL Switch Bundle
NOTE: The HP MSA2000sa 3Gb SAS BL Switch Bundle contains the following components:
HP MSA2012sa DC Modular Smart Array (Qty 1)
AJ948A
AJ949A
AJ808A
AJ749A
AJ750A
AJ751A
AG779A
AJ805A
AJ807A
AJ950A
AJ951A
AM337A
AJ754A
AP813A
AP716A
QuickSpecs
HP StorageWorks 2000sa G2 Modular Smart Array
Models
HP 3Gb SAS BL Switches (Qty 2)
HP
Blade Mezzanine
Module
1.The SAS Switch is supported only in the HP
2.The switch is placed into an interconnect bay in the back of the
3.(2) SAS Switches are required in the same
4.For the C3000 enclosure, the SAS Switch can only be placed into interconnect bays (3 and 4)
5.For the C7000 enclosure, the SAS Switch can only be placed into interconnect bays (3 and 4), or (5 and 6) or (7 and 8). The preferred interconnect bays are (5 and 6) then (7 and 8).
6.For the C3000 enclosure, using a server's mezzanine slot 1 along with enclosure interconnect bay 2 is not supported.
1.A half height blade server must have a P700m
2.A full height blade server must have a P700m
3.A double density blade server must have a P700m
QuickSpecs
HP StorageWorks 2000sa G2 Modular Smart Array
Features and Benefits
Key Hardware Features
Highly efficient consolidation and sharing of storage geared to departmental and small to medium business requirements
Cost efficient plus
Flexibility in drives: LFF MSA2
Large capacity SATA drives for inexpensive archival storage
Able to mix SAS and SATA drives within the same drive enclosure Choose either single or dual controller array models to fit the budget
Choice of low cost single I/O or
Customer Benefits
The HP StorageWorks 2000 Modular Smart Array family manages growing storage requirements across multiple HP ProLiant servers for customers who need a centralized dedicated storage solution for applications. Shared storage allows for controlled,
Its ease of management allows a department or small company to effectively handle growing storage requirements with a minimum of complexity.
The MSA2000sa G2 extends the benefits of shared storage resources to first time implementers on a tight budget Depending on the model chosen, the modular design allows the user to start relatively small but supports future growth to hundreds of users and up to 27 TB of LFF SAS or 60 TB of LFF SATA storage, or 29.7 TB of SFF SAS or 24.7 TB of SFF SATA storage.
The optional
QuickSpecs
HP StorageWorks 2000sa G2 Modular Smart Array
At a Glance
HP MSA2000sa G2 At a Glance:
High performance Modular Smart Array controller with four 3Gb SAS ports per controller Single and dual controller capability
1 GB transportable cache per controller -
2U rack mount chassis combining both the controller and disk shelf
Twelve 3.5 inch
Supports expansion to 3 additional SFF enclosures (MSA70) for a maximum total of 99 SFF disks Redundant power supplies and fans are standard
RAID levels 0, 1, 3, 5, 6, 10, 50
Heterogeneous support for
Windows Server 2008 x64
Optional
QuickSpecs
HP StorageWorks 2000sa G2 Modular Smart Array
Family Information
*maximum available storage capacity depends on the RAID level being implemented, and is based on maximum number of LUNs and LUN size
** Supports up to 8 hosts with SAS direct connect and 64 hosts (BladeSystem servers) using 3Gb SAS BL switch
QuickSpecs
HP StorageWorks 2000sa G2 Modular Smart Array
Family Information
QuickSpecs
HP StorageWorks 2000sa G2 Modular Smart Array
Family Information
RAID 0, 1, 3, 5, 6, 10, 50 In addition to the usual RAID levels, the MSA2000 family features several important additional levels. RAID 6 is the highest level of RAID protection. It allocates two sets of parity data across drives and allows simultaneous write operations. It can withstand two simultaneous drive failures without downtime or data loss. RAID 10 is mirroring and striping without parity. It is the most popular of the multiple RAID levels, allowing large arrays with high performance in most cases and superior fault tolerance. RAID 50 combines the block striping and parity of RAID 5 with the straight block striping of RAID 0, yielding higher performance than RAID 5 through the addition of RAID 0, particularly during writes.
QuickSpecs
HP StorageWorks 2000sa G2 Modular Smart Array
Family Information
QuickSpecs
HP StorageWorks 2000sa G2 Modular Smart Array
Family Information
QuickSpecs
HP StorageWorks 2000sa G2 Modular Smart Array
Optional Software
Optional Software
Snap or clone data to test the performance of a software application on 'offline' production data
Snap or clone data to test how a software patch or enhancement will function on 'offline; production data
Path Failover (MPIO) MPIO Basic Failover for Windows provides a single
HP MPIO Full DSM for the MSA2000sa
Microsoft Windows 2008: Microsoft MPIO is bundled with Windows Server 2008 and must be installed as an operating system feature.
Failover support for Linux is with Device Mapper 4.0 or higher
Sun Solaris native MPxIO
HP StorageWorks HP StorageWorks Storage Mirroring Software provides
and failover technology continuously captures
Storage Mirroring Software supports:
Any DAS, NAS, and SAN storage device.
Any Windows ProLiant server including all ML, DL, and BL platforms
Many Windows platforms including Windows Server 2000, Windows Server 2003, Windows
QuickSpecs
HP StorageWorks 2000sa G2 Modular Smart Array
Optional Software
Server 2003 R2, Windows Storage Server 2003, Windows Storage Server 2003 R2,
Windows, and Windows on Itanium
For more information visit: http://h18006.www1.hp.com/products/storage/software/sm/index.html
QuickSpecs
HP StorageWorks 2000sa G2 Modular Smart Array
Service and Support, HP Care Pack, and Warranty Information
Enclosures, Hard drives, and Options for the MSA2000sa G2 carry their own warranty. Refer to HP's Limited Warranty Statement for more information.
The MSA2000sa has been designed with customer self repairable parts to minimize repair time and provide greater flexibility in performing defective parts replacement. Please refer to HP's limited warranty Statement and parts replacement instructions for further details.
http://h18006.www1.hp.com/products/storageworks/warranty.html
Products included in various Kits carry their own individual warranties.
NOTE: The warranty of the hard drive options purchased with the MSA2000sa product is different for SAS hard drives versus SATA hard drives. SAS hard drive options have a three year warranty and SATA hard drives options have a one year warranty. Reference HP's communication for further details: http://www.hp.com go to search, enter CN0089W
HP Care Pack Services. Scalable, Flexible, Dependable. Like your storage.
Your storage is evolving. Get scalable support that evolves with it. HP Care Pack Services is an
Protect your business beyond the warranty
Standard warranty protects against product defects and some causes of downtime. HP Care Pack Services helps you proactively guard against unplanned downtime which can reduce your productivity and profitability. By using a standard approach to warranty uplifts, such as HP Care Pack Services, customers can be certain of consistency of operations for both
Extending warranties with HP Care Pack Services
The key to normalizing the warranty of combined
Provide consistent, predictable levels of support across your entire department or business
Give you direct access to proven technical and
Are available whenever and wherever you do business
For many products,
NOTE: Care Pack Services availability may vary by product and country.
QuickSpecs
HP StorageWorks 2000sa G2 Modular Smart Array
Service and Support, HP Care Pack, and Warranty Information
QuickSpecs
HP StorageWorks 2000sa G2 Modular Smart Array
Service and Support, HP Care Pack, and Warranty Information
Services that will enhance the user experience in many product deployments.
Contact your HP sales rep or Channel Partner for assistance
Contact your HP sales rep or Channel Partner for assistance
QuickSpecs
HP StorageWorks 2000sa G2 Modular Smart Array
Service and Support, HP Care Pack, and Warranty Information
HP Remote Support Pack enhances HP Systems Insight Manager with intelligent event diagnosis plus the automatic submission of hardware event notifications securely to HP support, including acknowledgment and status returns. It adds remote configuration collections to allow the delivery of assessment and proactive services for your SAN storage and
QuickSpecs
HP StorageWorks 2000sa G2 Modular Smart Array
Configuration Information
QuickSpecs
HP StorageWorks 2000sa G2 Modular Smart Array
Configuration Information
Step 1 - MSA2000sa G2- Base Configuration
There are two
Step 2 - Options
Select each option with quantities specified.
Step 2a - Options
Step 2b - Choose Supported Options For SAS HBA
Step 2c - MSA2 SAS and SATA Drive Options
NOTE: SATA drives are designed for archival or reference data. They should not be used in a heavy or intense I/O environment. Those situations require the use of
QuickSpecs
HP StorageWorks 2000sa G2 Modular Smart Array
Configuration Information
Step 2d - Drive Enclosure Options
Should you want a drive enclosure, the model you choose depends on which array model it attaches to. If it is a single controller array, then choose the JBOD designated as "Single I/O". If it is attaching to a dual controller array then choose the "Dual I/O" JBOD
Step 2e - SAS Cable Options
QuickSpecs
HP StorageWorks 2000sa G2 Modular Smart Array
Configuration Information
Step 3 - Other MSA2000sa Options
Step 4 - Choose Rack Options
Select each required option with quantities specified.
Rack Cabinet, Customer Assembled
QuickSpecs
HP StorageWorks 2000sa G2 Modular Smart Array
Configuration Information
Configure to Order (CTO) Program Information
HP introduces the new Configure to Order program for the MSA2000 family The MSA2000 models and options may or may not be factory installed in a rack with
Orders to be shipped through the CTO process must have a minimum of two drives ordered per controller.
SAS Drives (SFF 2.5- inch)
Makes the standard MSA70 (above) into a dual I/O, dual domain JBOD NOTE: The I/O Module is a field upgradeable Option Kit the addition of which in the MSA70 will allow dual domain capability providing higher level of redundancy and reliability
SATA Drives (SFF 2.5- inch)
NOTE: Only Dual Port (DP) drives will work as
QuickSpecs
HP StorageWorks 2000sa G2 Modular Smart Array
Configuration Information
NOTE: SATA drives for the MSA70 are not dual port (DP) drives.
NOTE: Go to the HP Hard Drive Compatibility table for complete drive compatibility information (http://www.hp.com/products/harddiskdrives). Using hard drives in unsupported configurations will result in voiding the warranty and could result in damage to the drive and/or loss of data
QuickSpecs
HP StorageWorks 2000sa G2 Modular Smart Array
Technical Specifications
QuickSpecs
HP StorageWorks 2000sa G2 Modular Smart Array
Technical Specifications
?? Copyright 2009
The information contained herein is subject to change without notice.
Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Intel is a US registered trademark of Intel Corporation. Unix is a registered trademark of The Open Group.
The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.