HP StorageWorks
Part number:
second edition: March 2009
Legal and notice information
?? Copyright
The information combined herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.
Microsoft, Windows, Windows NT, and Windows XP are U.S. registered trademarks of Microsoft Corporation. UNIX?? is a registered trademark of The Open Group.
WARRANTY STATEMENT: To obtain a copy of the warranty for this product, see the warranty information website: http://www.hp.com/go/storagewarranty.
Contents
Front panel components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 MSA2324fc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Hard drive bay numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Rear panel components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 MSA2324fc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 MSA2000 3.5
Installation checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Connecting controller and MSA2000 3.5
Host system requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Connecting the enclosure to data hosts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Front panel LEDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Hard drive LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Rear panel LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 MSA2324fc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 MSA2000 3.5
Controller failure in a
4
6
Figures
1 Cabling connections between a
2Cabling connections between a
3Cabling connections between a
4 MSA2312fc exploded view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 5 MSA2324fc exploded view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 6 MSA2000 3.5
8
Tables
1 Document conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 2 Installation checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 3 Terminal emulator display settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 4 Terminal emulator connection settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 5 Hard drive LED combinations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 6 Power supply sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 7 Cooling fan sensor descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 8 Controller module temperature sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 9 Power supply temperature sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 10 Voltage sensor descriptions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 11 MSA2312fc parts list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 12 MSA2324fc parts list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 13 MSA2000 3.5
10
About this guide
This guide provides information about the HP StorageWorks 2324fc Modular Smart Array.
Intended audience
This guide is intended for use by system administrators and technicians who are experienced with the following:
???Direct attach storage (DAS) or storage area network (SAN) management
???Network administration
???Network installation
???Storage system installation and configuration
Prerequisites
Prerequisites for installing and configuring this product include familiarity with:
???Servers and computer networks
???Fibre Channel and Ethernet protocols
Related documentation
In addition to this guide, please refer to other documents for this product:
???HP StorageWorks MSA2000 Family SMU online help
???HP StorageWorks MSA2000 Family CLI online help
???HP StorageWorks MSA2000 Family CLI reference guide
These and other HP documents can be found on the HP documents web site: http://www.hp.com/support/.
Document conventions and symbols
Table 1 Document conventions
HP StorageWorks
WARNING! Indicates that failure to follow directions could result in bodily harm or death.
CAUTION: Indicates that failure to follow directions could result in damage to equipment or data.
IMPORTANT: Provides clarifying information or specific instructions.
NOTE: Provides additional information.
TIP: Provides helpful hints and shortcuts.
Rack stability
WARNING! To reduce the risk of personal injury or damage to equipment:
???Extend leveling jacks to the floor.
???Ensure that the full weight of the rack rests on the leveling jacks.
???Install stabilizing feet on the rack.
???In
???Extend only one rack component at a time. Racks may become unstable if more than one component is extended.
HP technical support
Telephone numbers for worldwide technical support are listed on the HP support web site: http://www.hp.com/support/.
Collect the following information before calling:
???Technical support registration number (if applicable)
???Product serial numbers
???Product model names and numbers
???Applicable error messages
???Operating system type and revision level
???Detailed, specific questions
For continuous quality improvement, calls may be recorded or monitored.
Customer self repair
HP customer self repair (CSR) programs allow you to repair your StorageWorks product. If a CSR part needs replacing, HP ships the part directly to you so that you can install it at your convenience. Some parts do not qualify for CSR. Your
For more information about CSR, contact your local service provider. For North America, see the CSR website:
12
Product warranties
For information about HP StorageWorks product warranties, see the warranty information website:
http://www.hp.com/go/storagewarranty
Subscription service
HP strongly recommends that customers sign up online using the Subscriber's choice web site:
???Subscribing to this service provides you with
???After signing up, you can quickly locate your products by selecting Business support and then Storage under Product Category.
HP web sites
For other product information, see the following HP web sites:
???http://www.hp.com/go/storage
Documentation feedback
HP welcomes your feedback.
To make comments and suggestions about product documentation, please send a message to storagedocs.feedback@hp.com. All submissions become the property of HP.
HP StorageWorks
14
1 Overview
The 2324fc Modular Smart Array is a
Features and benefits
Product features and supported options include:
???Supported servers
???HP ProLiant servers
???HP ProLiant
???HP Integrity servers
???Certain
???Supports most
???Primary supported operating systems
???Microsoft Windows Server
???VMware
???Red Hat Enterprise Linux
???SuSE Linux
???
NOTE: Check the QuickSpecs for a complete list of servers. QuickSpecs can be found from your HP MSA products page at http://www.hp.com/go/msa. Select MSA SAN Arrays, and then select your product. The link for QuickSpecs will be on the right.
???Capacity up to 99 small form factor (SFF) drives with MSA2324fc and three MSA70 enclosures
???Capacity up to four MSA2000 3.5
???Capacity up to 60 drives in a mixed drive environment: one MSA2324fc (24 SFF) and three MSA2000
3.5
???Supported drives:
??? MSA2
???450GB/300GB/146GB 15K RPM DP SAS
???1TB/750GB/500GB 7.2K RPM DP SATA
???HP ProLiant
???72GB/36GB 15K RPM SP SAS
???72GB/36GB 15K RPM DP SAS
???146GB/72GB 10K RPM SP SAS
???146GB/72GB 10K RPM DP SAS
???120GB/60GB 5.4K RPM SATA
???250GB 5.4K RPM SATA
???Two
???
???
NOTE: Check the QuickSpecs for an updated list of supported operating systems and drives. QuickSpecs can be found from your HP MSA products page at http://www.hp.com/go/msa. Select MSA SAN Arrays, and then select your product. The link for QuickSpecs will be on the right.
HP StorageWorks
16 Overview
2 Components
Front panel components
MSA2324fc
1
4 5 6
HP StorageWorks
Hard drive bay numbers
MSA2324fc
Rear panel components
MSA2324fc
9
18 Components
MSA2000 3.5
1Power supplies
2Power switches
3SAS In port (connects to a controller enclosure)
4Service port (used by service personnel only)
5SAS Out port (connects to another drive enclosure)
6Optional I/O module
NOTE: The MSA2324fc can also be attached to an MSA70 that is running firmware version 2.18 or later. For information about the MSA70, see the HP StorageWorks 70 Modular Smart Array Enclosure user guide located on the MSA2000 Software Support/Documentation CD shipped with your product or at http://hp.com/support/manuals.
Cache
To enable faster data access from disk storage, the following two types of caching are performed:
???
???
Transportable CompactFlash
During a power loss or array controller failure, data stored in cache is saved off to
In
CompactFlash
HP StorageWorks
CAUTION: To preserve the existing data stored in the CompactFlash, you must transport the CompactfFash from the failed controller to the replacement controller using a procedure outlined in the HP StorageWorks 2312fc/2324fc controller replacement instructions, shipped with the replacement controller. Failure to use this procedure will result in the loss of data stored in the cache module. The CompactFlash must stay with the same enclosure. If the CompactFlash is used/installed in a different enclosure, data loss/data corruption will occur.
IMPORTANT: In dual controller configurations, there is no need to transport a failed controller???s cache to a replacement controller because the cache is duplicated between the controllers.
To protect RAID controller cache in case of power failure, the MSA2324fc is equipped with
20 Components
3 Installing the enclosures
Installation checklist
The following table outlines the steps required to install the enclosures and initially configure the system. To ensure a successful installation, perform the tasks in the order they are presented.
NOTE: For help with installing your MSA2000 product, also see the MSA2000 Software Support/Documentation CD shipped with your product.
HP StorageWorks
Connecting controller and MSA2000 3.5
You can connect up to three MSA2000 3.5
IMPORTANT: Connecting an MSA2000 3.5
IMPORTANT: The MSA2324fc can also be attached to an MSA70 that is running firmware version 2.18 or later. For information about the MSA70, see the HP StorageWorks 70 Modular Smart Array Enclosure user guide located on the MSA2000 Software Support/Documentation CD shipped with your product or at http://hp.com/support/manuals.
When connecting multiple drive enclosures, use reverse cabling to ensure the highest level of fault tolerance. Controllers and I/O (expansion) modules are identified by
NOTE: For clarity, the schematic illustrations of the controllers shown in this section show only relevant details such as expansion ports. For detailed illustrations showing all components, see Rear panel components.
1A
1B
Figure 1 Cabling connections between a
22 Installing the enclosures
1A
1B
Figure 2 Cabling connections between a
1A
1B
Figure 3 Cabling connections between a
HP StorageWorks
Testing enclosure connections
1. Press the power switches at the back of each drive enclosure to On.
IMPORTANT: This ensures that the disks in the enclosures have enough time to completely spin up before being scanned by the RAID modules in the controller enclosure.
While enclosures power up, their LEDs blink. After the LEDs stop blinking, if no LEDs on the front and back of the enclosure are amber, the
For a description of LED behavior and status, see LED descriptions.
2.Press the power switches at the back of the controller enclosure to On.
Depending on the number and type of drives in the system, it can take several minutes for the system to power up.
If the enclosure???s
Obtaining IP values
NOTE: For help with configuring your MSA2000 product, also see the MSA2000 Software Support/Documentation CD shipped with your product.
Setting management port IP addresses using DHCP
1.Look in the DHCP server???s pool of leased addresses for two IP addresses assigned to ???HP StorageWorks MSA Storage.???
2.Use a network management utility to discover ???HP StorageWorks MSA2300fc??? storage devices on the local LAN through SNMP.
3.Use a ping broadcast to try to identify the device through the host???s ARP table.
If you do not have a DHCP server, you will need to ask your system administrator to allocate two IP addresses and set them using the CLI during initial configuration (see Setting management port IP addresses using the CLI).
Setting management port IP addresses using the CLI
NOTE: If you used DHCP to set the IP addresses, you do not have to set them using the CLI as described in this section.
Ethernet Management ports on controller module A and controller module B are configured with the following default values:
???Management Port IP Address: 10.0.0.2 (controller A), 10.0.0.3 (controller B)
???IP Subnet Mask: 255.255.255.0
???Gateway IP Address: 10.0.0.1
If the default IP addresses are not compatible with your network, you must set an IP address for each management port using the
Use the CLI commands described in the steps below to set the IP address for the Ethernet management port on each controller module.
Once new IP addresses are set, you can change them as needed using SMU.
NOTE: Changing IP settings can cause management hosts to lose access to the storage system.
24 Installing the enclosures
1.From your network administrator obtain an IP address, subnet mask, and gateway address for controller A and controller B.
2.Use the provided
Your package contents include a
3.Start and configure a terminal emulator, such as HyperTerminal or
Table.3 Terminal emulator display settings
4. In the terminal emulator, connect to controller A. Table 4 Terminal emulator connection settings
5. Press Enter to display the CLI prompt (#).
HP StorageWorks
6.At the prompt, type the following command to set the values you obtained in Step 1 for each Ethernet management port, first for controller A and then for controller B:
set
where:
???address is the IP address of the controller
???netmask is the subnet mask
???gateway is the IP address of the subnet router
???a|b specifies the controller whose network parameters you are setting
For example:
#set
#set
7.Type the following command to verify the new IP addresses:
show
Network parameters, including the IP address, subnet mask, and gateway address are displayed for each controller.
a.From the CLI you can use the PING command to verify network connectivity For example:
# ping 16.125.12.1
Info: Pinging 16.125.12.1 with 4 packets.
Success: Command completed successfully. The remote computer responded with 4 packets.
8.Disconnect from the CLI and exit the emulator.
9.In the host computer's command window, type the following command to verify Ethernet connectivity, first for controller A and then for controller B:
ping
If you cannot your access your system for at least three minutes after changing the IP address, your network might require you to restart the management controller using the serial CLI. When you restart a management controller, communication with it is temporarily lost until it successfully restarts.
Type the following command to restart the management controller on both controllers:
restart mc both
Installing the HP seismic rack mounting kit
To install the HP Seismic Rack Mounting kit, follow these steps:
26 Installing the enclosures
1. Attach the rear brackets to the MSA2324
2.Attach the left bracket assembly to the left rack rail.
3.Attach the right bracket assembly to the right rack rail.
4.Insert cage nuts into the rack holes.
5.Align the MSA2324 CG with the rails, and then slide it into the rack until the ears of the MSA2324CG are about 1 to 2 inches from the rack front rails.
6.Attach a flat washer between the right mounting ear (bottom hole) and the rack, and then loosely attach the bracket to the rear bracket assemblies.
7.Attach the
HP StorageWorks
28 Installing the enclosures
8. Loosely attach the rear brackets to the rear bracket assemblies.
9.Attach the loose end of the ground cable to the front rack ground rail.
10.Verify that the MSA2324 CG is evenly spaced between the right and left rack rails, and then tighten the front and rear bracket screws.
HP StorageWorks
30 Installing the enclosures
4 Connecting hosts
Host system requirements
Data hosts connected to MSA2324fc arrays must meet the following requirements:
???Depending on your system configuration, data host operating systems may require that multipathing is supported.
If fault tolerance is required, then multipathing software may be required.
To obtain the MSA2000 Family MPIO DSM, go to the HP MSA products page at http://www.hp.com/go/msa. Select MSA SAN Arrays, select your product, and go to Related products.
???To prevent Microsoft Windows 2003 data hosts from displaying the Found New Hardware Wizard when the storage system is discovered, install the MSA2000 Family SCSI Enclosure Services driver. Download MSA2000 Family SCSI Enclosure Services (SES) driver package from http://www.hp.com/go/msa. Select MSA SAN Arrays, select your product, and go to Related products.
NOTE: The MSA2000 Family SCSI Enclosure Services driver is required for Microsoft Windows 2003.
Connecting the enclosure to data hosts
Cable connections vary depending on configuration. Common cable configurations are shown in this section. For a complete list of supported configurations, go to the MSA2000 product site at http://hp.com/support/manuals for the latest MSA2000 supported cable configurations guide. This document is updated whenever newly supported configurations are added.
The 2324fc Modular Smart Array uses Fibre Channel Arbitrated Loop (loop) topology by default.
Connecting direct attach configurations
Single controller configuration
One server/one HBA/single path
Server 1
Dual controller configurations
One server/one
Server 1
HP StorageWorks
Two servers/one
Server 1
Server 2
Connecting switch attach configurations
Two servers/two switches
Connecting remote management hosts
The management host directly manages systems
1.Connect an Ethernet cable to the Ethernet management port on each controller.
2.Connect the other end of each Ethernet cable to a network that your management host can access (preferably on the same subnet).
NOTE: Connections to this device must be made with shielded cables with metallic RFI/EMI connector hoods in order to maintain compliance with FCC Rules and Regulations.
28 Connecting hosts
5 Basic operation
Powering on/powering off
Before powering on the enclosure for the first time:
???Install all hard drives in the enclosure so that the connected host controller can identify and configure them at
???Connect the cables and power cords to the enclosure as explained in the Installation Poster.
???Generally when powering up, make sure to power up the enclosures and associated data host in the following order:
???Drive enclosures first
???Controller enclosure next
???Data hosts last (if they are powered down for maintenance purposes)
To power on the system:
1.Press the power switches at the back of each drive enclosure to the On position.
2.Press the power switches at the back of the controller enclosure to the On position.
To power off the system:
1.Stop all I/O from hosts to the system.
2.Use SMU to shut down both controllers. See the SMU online help or CLI reference guide for information on shutting down controller.s
Wait until SMU indicates that processing is complete.
3.Press the power switches at the back of the controller enclosure to the Off position.
4.Press the power switches at the back of each drive enclosure to the Off position.
Updating firmware
After installing the hardware and powering up the enclosure for the first time, be sure to verify that the controllers and drive enclosures have the latest firmware. SMU enables you to view the software, hardware, and other version information for each controller and the enclosures.
To view controller version information, in the Configuration View panel,
For software and firmware updates, including language packages and firmware update instructions, go to http://www.hp.com/go/msa. Select MSA SAN Arrays, select your product, and go to Support.
Selecting an appropriate time to perform the online upgrade
To ensure the success of an online upgrade, selecting the appropriate time is essential. Selecting a period of low I/O activity will ensure the upgrade completes as quickly as possible, and will avoid disruptions to host and applications due to timeouts. Attempting to upgrade a storage system that is in the middle of processing a large I/O intensive batch job will likely cause hosts to lose connectivity with the storage system. Consequently, finding an appropriate time for the upgrade is very important.
For software and firmware updates, go to http://www.hp.com/go/msa. Select MSA SAN Arrays, select your product, and go to Support.
For detailed steps on updating the firmware, see the reference guide or the CLI reference guide. For information on logging into SMU, see Configuring a system for the first time.
HP StorageWorks
30 Basic operation
6 LED descriptions
Front panel LEDs
HP StorageWorks
Hard drive LEDs
1 2
2 1
LED Description
1Fault/UID (amber/blue)
2Online/Activity (green)
Table 5 Hard drive LED combinations
32 LED descriptions
Table 5 Hard drive LED combinations (continued)
HP StorageWorks
Rear panel LEDs
MSA2324fc
34 LED descriptions
HP StorageWorks
MSA2000 3.5
1 2
36 LED descriptions
Power supply LEDs
Power redundancy is achieved through two independent
11
AC modelDC model
HP StorageWorks
38 LED descriptions
7 Configuring a system for the first time
Configuring your web browser for SMU
Before using SMU to perform remaining steps, ensure that your web browser is properly configured according to the following guidelines:
???Your browser must be Internet Explorer 7 or Mozilla Firefox 1.5 or later. (Check the QuickSpecs for an updated list of supported browsers. QuickSpecs can be found from your HP MSA products page at http://www.hp.com/go/msa. Select MSA SAN Arrays, and then select your product. The link for QuickSpecs will be on the right.)
???To see the help window, you must enable
???To optimize the display, use a color monitor and set its color quality to the highest setting.
???To navigate beyond the Sign In page (with a valid user account):
???Set the browser???s
???Verify that the browser is set to allow cookies at least for the IP addresses of the
Logging in to SMU from a local management host
To log in to SMU from a local management host:
1.In the web browser???s address field, type the IP address of one of the controller enclosure???s Ethernet management ports and press Enter.
The SMU Sign In page is displayed. If the
2.On the Sign In page, type the default management user name manage and default password
!manage.
If you are logging in to the SMU for the first time and no language packages have been installed, the Language field displays user setting or English, either of which when selected results in English. See the reference guide for information on configuring languages.
3.Click Sign In.
The System Overview page is displayed.
Tips for using the main window
???The Configuration View panel displays logical and physical components of the storage system. To perform a task, select the component to act on and then either:
???
???Click a task category in the main panel and select the task to perform.
???The System Status panel shows how many events of each severity have occurred in the system. To view event details, click a severity icon.
???Many tables can be sorted by a specific column. To do so, click the column heading to sort low to high; click again to sort high to low.
???Do not use the browser's Back, Forward, Reload, or Refresh buttons. The application is essentially a single page that is automatically updated to show current data. You do not need to refresh it and if you click Back, you may exit the application.
???If an option name has an asterisk (*), the option is required.
HP StorageWorks
Tips for using the help window
???In the main panel, clicking the help icon displays help for the
???In the help window, clicking the arrowed border on the left displays or hides the help contents pane.
A topic remains displayed until you browse to another topic in the help window, display help for a different item in the main window, or close the help window.
Changing the system date and time
You can change the storage system's date and time, which are displayed in the System Status panel. It is important to set the date and time so that entries in system logs and
You can set the date and time manually or configure the system to use Network Time Protocol (NTP) to obtain them from a
NTP server time is provided in Universal Time (UT), which provides several options:
???If you want to synchronize the times and logs between storage devices installed in multiple time zones, set all the storage devices to use UT.
???If you want to use the local time for a storage device, set its time zone offset.
???If a time server can provide local time rather than UT, configure the storage devices to use that time server, with no further time adjustment.
To use manual date and time settings
1.In the Configuration View panel,
2.Set the options:
???Time. Enter the time in the format hh:mm:ss.
???Month.
???Day.
???Year. Enter the year using four digits.
???NTP. Select Disabled.
3.Click Set Time Values.
To obtain the date and time from an NTP server
1.In the Configuration View panel,
2.Set the options:
???NTP. Select Enabled.
???NTP Time Zone Offset. Optional. If the system timestamps should use the NTP server's time zone instead of the local time zone, enter the time zone offset.
???NTP Server Address. Optional. If the system should retrieve time values from a specific NTP server, enter the address of an NTP server. If no IP server address is set, the system listens for time messages sent by an NTP server in broadcast mode.
3.Click Set Time Values.
40 Configuring a system for the first time
Using the Configuration Wizard
The Configuration Wizard helps you initially configure the system or change system configuration settings. The wizard has several steps, which are highlighted at the bottom of the panel as you complete them. The last step prompts you to confirm changes before applying them. If you cancel the wizard, no changes are made.
To use the wizard, in the Configuration View panel,
???Password setup (manage and monitor).
???Network configuration, including IP addresses, IP mask, and gateway for controller A and controller B.
???
???Web Browser Interface (WBI). The primary interface for managing the system. You can enable use of HTTP, of HTTPS for increased security, or both.
???Command Line Interface (CLI). An advanced user interface for managing the system. You can enable use of Telnet, of SSH (secure shell) for increased security, or both.
???Storage Management Initiative Spec (SMIS). Used for remote management of the system through your network.
???File Transfer Protocol (FTP). Used as an alternative to the WBI for installing firmware updates and collecting diagnostic bugs.
???Simple Network Mgmt Protocol (SNMP). Used for remote monitoring of the system through your network.
???Service Interface. Used for technical support only.
???Service Debug. Used for technical support only.
???Inband CAPI Capability. Used for
???Inband SES Capability. Used for
If a service is disabled, it continues to run but cannot be accessed.
???System information, including system name, contact, location, and description.
???Up to four email addresses and three SNMP trap hosts to receive notifications of system events.
???Parameters for FC and iSCSI controller host ports.
HP StorageWorks
Using the Provisioning Wizard
The Provisioning Wizard helps you create a vdisk with volumes and to map the volumes to hosts. The wizard has several steps, which are highlighted at the bottom of the panel as you complete them. The last step prompts you to confirm changes before applying them. If you cancel the wizard, no changes are made.
To use the wizard, in the Configuration View panel,
???The vdisk name and RAID level appropriate for the level of fault tolerance that the vdisk???s data will require. If you select
???Disks to include in the vdisk. The table specifies the minimum and maximum number of disks to select. Only available disks can be selected.
???Number and size of volumes to create in the vdisk. By default the new vdisk will have one volume. You can change the number of volumes and optionally change the default size and base name for the volumes. To postpone creating volumes, you can change the number of volumes to zero.
???The default mapping allows no access to the volume by all hosts.
Testing the configuration
To determine that your system is ready for use, test the configuration as follows:
1.Using SMU,
2.From the data host:
b.Create a file system on the volume.
c.Verify that you can access the mapped volume and the volume size shown on the data host matches the size shown in SMU.
d.Verify that you can write data to the volume.
If the above tests succeed, your system is ready for use.
3.Optionally, unmount the volume and delete the vdisks for test.
Logging out of SMU
If you do not log out of SMU when you have finished using it, other manage users cannot log in to the same controller module and your IP address stays logged in for 30 minutes (the default
1.Click Sign Out in the upper
2.Click Logout.
42 Configuring a system for the first time
8 Troubleshooting
Fault isolation methodology
The MSA2000 Family storage system provides many ways to isolate faults within the system. This section presents the basic methodology used to locate faults and the associated FRUs.
The basic fault isolation steps are:
???Gather fault information, including using system LEDs
???Determine where in the system the fault is occurring
???Review event logs
???If required, isolate the fault to a data path component
Gather fault information
When a fault occurs, it is important to gather as much information as possible. Doing so will help you determine the correct action needed to remedy the fault.
Begin by reviewing the reported fault. Is the fault related to an internal data path or an external data path? Is the fault related to a hardware component such as a drive module, controller module, or power supply? By isolating the fault to one of the components within the storage system, you will be able to determine the necessary action more rapidly.
Determine where the fault is occurring
Once you have an understanding of the reported fault, review the enclosure LEDs. The enclosure LEDs are designed to alert users of any system faults and might be what alerted the user to a fault in the first place.
When a fault occurs, the Fault ID status LED on an enclosure???s right ear (see Front panel components) illuminates. Check the LEDs on the back of the enclosure to narrow the fault to a FRU, connection, or both. The LEDs also help you identify the location of a FRU reporting a fault.
Use SMU to verify any faults found while viewing the LEDs. SMU is also a good tool to use in determining where the fault is occurring if the LEDs cannot be viewed due to the location of the system. SMU provides you with a visual representation of the system and where the fault is occurring. It can also provide more detailed information about FRUs, data, and faults.
Review the event logs
The event logs record all system events. It is very important to review the logs, not only to identify the fault, but also to search for events that might have caused the fault to occur. For example, a host could lose connectivity to a virtual disk if a user changes channel settings without taking the storage resources assigned to it into consideration. In addition, the type of fault can help you isolate the problem to hardware or software.
Isolate the fault
Occasionally it might become necessary to isolate a fault. This is particularly true with data paths due to the number of components the data path consists of. For example, if a
If the enclosure does not initialize
It may take up to two minutes for the enclosures to initialize. If the enclosure does not initialize:
???Perform a rescan.
???Power cycle the system.
???Make sure the power cord is properly connected and check the power source that it is connected to.
???Check the event log for errors.
HP StorageWorks
Correcting enclosure IDs
When installing a system with drive enclosures attached, the enclosure IDs might not agree with the physical cabling order. This is because the controller might have been previously attached to some of the same enclosures during factory testing and it attempts to preserve the previous enclosure IDs if possible. To correct this condition, make sure that both controllers are up and perform a rescan using SMU or the CLI. This will reorder the enclosures, but can take up to two minutes for the enclosure IDs to be corrected.
To perform a rescan using the CLI, type the following command:
rescan
To rescan using SMU:
1.Verify that both controllers are operating normally.
2.In the Configuration View panel,
3.Click Rescan.
Diagnostic steps
This section describes possible reasons and actions to take when an LED indicates a fault condition. See LED descriptions for descriptions of all LED statuses.
Is the front panel Fault LED amber?
Is the controller back panel OK LED off?
Is the controller back panel Fault/Service Required LED amber?
44 Troubleshooting
Are both drive module LEDs off (Online/Activity and Fault/UID)?
Is the drive module Fault/UID LED blinking amber?
Is a connected host port???s Host Link Status LED off?
HP StorageWorks
Is a connected port???s Expansion Port Status LED off?
Is a connected port???s Ethernet link status LED off?
Is the power supply???s AC Power Good LED off?
46 Troubleshooting
Is the drive enclosure back panel OK LED off?
Is the drive enclosure Fault/Service Required LED amber?
HP StorageWorks
Controller failure in a
Cache memory is flushed to CompactFlash in the case of a controller failure or power loss. During the write to CompactFlash process only the components needed to write the cache to the CompactFlash are powered by the
IMPORTANT: Transportable cache only applies to
If the controller has failed or does not start, is the Cache Status LED on/blinking?
Transporting Cache
To preserve the existing data stored in the CompactFlash, you must transport the CompactFlash from the failed controller to a replacement controller using a procedure outlined in the HP StorageWorks 2312fc/2324fc controller replacement instructions, shipped with the replacement controller. Failure to use this procedure will result in the loss of data stored in the cache module.
CAUTION: Remove the controller only after the copy process is complete, which is indicated by the Cache Status LED being off.
48 Troubleshooting
Isolating a
During normal operation, when a controller module host port is connected to a data host, the port???s host link status LED and host link activity LED are green. If there is I/O activity, the host activity LED blinks green. If data hosts are having trouble accessing the storage system, and you cannot locate a specific fault or cannot access the event logs, use the following procedure. This procedure requires scheduled downtime.
IMPORTANT: Do not perform more than one step at a time. Changing more than one variable at a time can complicate the troubleshooting process.
1.Halt all I/O to the storage system.
2.Check the host activity LED.
If there is activity, halt all applications that access the storage system.
3.Reseat the SFP and FC cable. Is the host link status LED on?
???Yes ??? Monitor the status to ensure that there is no intermittent error present. If the fault occurs again, clean the connections to ensure that a dirty connector is not interfering with the data path.
???No ??? Proceed to the next step.
4.Move the SFP and cable to a port with a known good link status.
This step isolates the problem to the external data path (SFP, host cable, and
Is the host link status LED on?
???Yes ??? You now know that the SFP, host cable, and
???No ??? Proceed to the next step.
5.Swap the SFP with the known good one. Is the host link status LED on?
???Yes ??? You have isolated the fault to the SFP. Replace the SFP.
???No ??? Proceed to the next step.
6.
???Yes ??? You have isolated the fault to the cable. Replace the cable.
???No ??? Proceed to the next step.
7.Replace the HBA with a known good HBA, or move the host side cable and SFP to a known good HBA.
Is the host link status LED on?
???Yes ??? You have isolated the fault to the HBA. Replace the HBA.
???No ??? It is likely that the controller module needs to be replaced.
8.Move the cable and SFP back to its original port. Is the host link status LED on?
???No ??? The controller module???s port has failed. Replace the controller module.
???Yes ??? Monitor the connection for a period of time. It may be an intermittent problem, which can occur with SFPs, damaged cables, and HBAs.
HP StorageWorks
Isolating a controller module expansion port connection fault
During normal operation, when a controller module???s expansion port is connected to a drive enclosure, the expansion port status LED is green. If the connected port???s expansion port LED is off, the link is down. Use the following procedure to isolate the fault.
This procedure requires scheduled downtime.
NOTE: Do not perform more than one step at a time. Changing more than one variable at a time can complicate the troubleshooting process.
1.Halt all I/O to the storage system.
2.Check the host activity LED.
If there is activity, halt all applications that access the storage system.
3.Reseat the expansion cable.
Is the expansion port status LED on?
???Yes ??? Monitor the status to ensure there is no intermittent error present. If the fault occurs again, clean the connections to ensure that a dirty connector is not interfering with the data path.
???No ??? Proceed to Step 4.
4.Move the expansion cable to a port on the RAID enclosure with a known good link status.
This step isolates the problem to the expansion cable or to the controller module???s expansion port. Is the expansion port status LED on?
???Yes ??? You now know that the expansion cable is good. Return cable to the original port. If the expansion port status LED remains off, you have isolated the fault to the controller module???s expansion port. Replace the controller module.
???No ??? Proceed to the next step.
5.Move the expansion cable back to the original port on the controller enclosure.
6.Move the expansion cable on the drive enclosure to a known good expansion port on the drive enclosure.
Is the expansion port status LED on?
???Yes ??? You have isolated the problem to the drive enclosure???s port. Replace the expansion module.
???No ??? Proceed to Step 7.
7.Replace the cable with a known good cable, ensuring the cable is attached to the original ports used by the previous cable.
Is the host link status LED on?
???Yes ??? Replace the original cable. The fault has been isolated.
???No ??? It is likely that the controller module needs to be replaced
Resolving voltage and temperature warnings
1.Check that all of the fans are working by making sure each power supply???s DC Voltage/Fan Fault/Service Required LED is off or by using SMU to check for yellow yield icon hardware warnings. (In the Configuration View panel, right click the enclosure and click View > Overview.)
2.Make sure that all modules are fully seated in their slots and that their latches are locked.
3.Make sure that no slots are left open for more than two minutes.
If you need to replace a module, leave the old module in place until you have the replacement or use a blank module to fill the slot. Leaving a slot open negatively affects the airflow and can cause the enclosure to overheat.
4.Try replacing each power supply one at a time.
5.Replace the controller modules one at a time.
50 Troubleshooting
Sensor locations
The storage system monitors conditions at different points within each enclosure to alert you to problems. Power, cooling fan, temperature, and voltage sensors are located at key points in the enclosure. In each controller module and expansion module, the enclosure management processor (EMP) monitors the status of these sensors to perform SCSI enclosure services (SES) functions.
The following sections describe each element and its sensors.
Power supply sensors
Each enclosure has two fully redundant power supplies with
Table 6 Power supply sensors
Cooling fan sensors
Each power supply includes two fans. The normal range for fan speed is 4000 to 6000 RPM. When a fan???s speed drops below 4000 RPM, the EMP considers it a failure and posts an alarm in the storage system???s event log. The following table lists the description, location, and alarm condition for each fan. If the fan speed remains under the 4000 RPM threshold, the internal enclosure temperature may continue to rise. Replace the power supply reporting the fault.
Table 7 Cooling fan sensor descriptions
During a shutdown, the cooling fans do not shut off. This allows the enclosure to continue cooling.
Temperature sensors
Extreme high and low temperatures can cause significant damage if they go unnoticed. Each controller module has six temperature sensors. Of these, if the CPU or FPGA temperature reaches a shutdown value, the controller module is automatically shut down. Each power supply has one temperature sensor.
When a temperature fault is reported, it must be remedied as quickly as possible to avoid system damage. This can be done by warming or cooling the installation location.
Table 8 Controller module temperature sensors
HP StorageWorks
Table 8 Controller module temperature sensors (continued)
When a power supply sensor goes out of range, the Fault/ID LED illuminates amber and an event is logged to the event log.
Table 9 Power supply temperature sensors
Power supply module voltage sensors
Power supply voltage sensors ensure that an enclosure???s power supply voltage is within normal ranges. There are three voltage sensors per power supply.
Table 10 Voltage sensor descriptions
52 Troubleshooting
A.Parts catalog
This product contains the parts illustrated in Figure 4, Figure 5, and Figure 6.
Parts that are available for customer self repair (CSR) are indicated as follows:
NOTE: For an updated list of customer self repair parts, go to http://www.hp.com/support/.
HP StorageWorks
F
7
6
5
3
4
1
2
Figure 4 MSA2312fc exploded view
Table 11 MSA2312fc parts list
54 Parts catalog
Table 11 MSA2312fc parts list (continued)
HP StorageWorks
7
6
5
1 2
Figure 5 MSA2324fc exploded view
Table 12 MSA2324fc parts list
56 Parts catalog
Table 12 MSA2324fc parts list (continued)
HP StorageWorks
6
5
1
2
Figure 6 MSA2000 3.5
Table 13 MSA2000 3.5
58 Parts catalog
???For more information about CSR, contact your local service provider. For North America, see the CSR website at http://www.hp.com/go/selfrepair.
???To determine the warranty service provided for this product, see the warranty information website at http://www.hp.com/go/storagewarranty.
???To order a replacement part, contact an
HP StorageWorks
60 Parts catalog
B Environmental requirements and specifications
Safety requirements
Install the system in accordance with the local safety codes and regulations at the facility site. Follow all cautions and instructions marked on the equipment.
Site requirements and guidelines
The following sections provide requirements and guidelines that you must address when preparing your site for the installation.
When selecting an installation site for the system, choose a location not subject to excessive heat, direct sunlight, dust, or chemical exposure. These conditions greatly reduce the system???s longevity and might void your warranty.
Site wiring and AC power requirements
The following are required for all installations using AC power supplies:
???All AC mains and supply conductors to power distribution boxes for the
???Ensure that the voltage and frequency of your power source match the voltage and frequency inscribed on the equipment???s electrical rating label.
???To ensure redundancy, provide two separate power sources for the enclosures. These power sources must be independent of each other, and each must be controlled by a separate circuit breaker at the power distribution point.
???The system requires voltages within minimum fluctuation. The
???Site wiring must include an earth ground connection to the AC power source. The supply conductors and power distribution boxes (or equivalent metal enclosure) must be grounded at both ends.
???Power circuits and associated circuit breakers must provide sufficient power and overload protection. To prevent possible damage to the AC power distribution boxes and other components in the rack, use an external, independent power source that is isolated from large switching loads (such as air conditioning motors, elevator motors, and factory loads).
Site wiring and DC power requirements
The following are required for all installations using DC power supplies:
???All DC mains and supply conductors to power distribution boxes for the
???Ensure that the voltage of your power source matches the voltage inscribed on the equipment???s electrical label.
???To ensure redundancy, provide two separate power sources for the enclosures. These power sources must be independent of each other, and each must be controlled by a separate circuit breaker at the power distribution point.
???The system requires voltages within minimum fluctuation. The
???Site wiring must include an earth ground connection to the DC power source. Grounding must comply with local, national, or other applicable government codes and regulations.
???Power circuits and associated circuit breakers must provide sufficient power and overload protection.
HP StorageWorks
Weight and placement guidelines
Refer to Physical requirements for detailed size and weight specifications.
???The weight of an enclosure depends on the number and type of modules installed.
???Ideally, use two people to lift an enclosure. However, one person can safely lift an enclosure if its weight is reduced by removing the power and cooling modules and drive modules.
???Do not place enclosures in a vertical position. Always install and operate the enclosures in a horizontal orientation.
???When installing enclosures in a rack, make sure that any surfaces over which you might move the rack can support the weight. To prevent accidents when moving equipment, especially on sloped loading docks and up ramps to raised floors, ensure you have a sufficient number of helpers. Remove obstacles such as cables and other objects from the floor.
???To prevent the rack from tipping and to minimize personnel injury in the event of a seismic occurrence, securely anchor the rack to a wall or other rigid structure that is attached to both the floor and to the ceiling of the room.
Electrical guidelines
???These enclosures work with
???Enclosures are shipped with a
???Do not use household extension cords with the enclosures. Not all power cords have the same current ratings. Household extension cords do not have overload protection and are not meant for use with computer systems.
Ventilation requirements
Refer to Environmental requirements for detailed environmental requirements.
???Do not block or cover ventilation openings at the front and rear of an enclosure. Never place an enclosure near a radiator or heating vent. Failure to follow these guidelines can cause overheating and affect the reliability and warranty of your enclosure.
???Leave a minimum of 6 inches (15 cm) at the front and back of each enclosure to ensure adequate airflow for cooling. No cooling clearance is required on the sides, top, or bottom of enclosures.
???Leave enough space in front and in back of an enclosure to allow access to enclosure components for servicing. Removing a component requires a clearance of at least 15 inches (37 cm) in front of and behind the enclosure.
Cabling requirements
???Keep power and interface cables clear of foot traffic. Route cables in locations that protect the cables from damage.
???Route interface cables away from motors and other sources of magnetic or radio frequency interference.
???Stay within the cable length limitations.
Management host requirements
A local management host with at least one serial port connection is recommended for the initial installation and configuration of a controller enclosure. After you configure one or both of the controller modules with an Internet Protocol (IP) address, you then use a remote management host on an Ethernet network to configure, manage, and monitor.
62 Environmental requirements and specifications
NOTE: Connections to this device must be made with shielded cables with metallic RFI/EMI connector hoods in order to maintain compliance with FCC Rules and Regulations.
Physical requirements
The floor space at the installation site must be strong enough to support the combined weight of the rack, controller enclosures, expansion enclosures, and any additional equipment. The site also requires sufficient space for installation, operation, and servicing the enclosures, and also requires sufficient ventilation to allow a free flow of air to all enclosures.
Table 14 and Table 15 list enclosure dimensions and weights. Weights are based on an enclosure having 12 drive modules, two controller or expansion modules, and two power supplies installed.
Table.14 Rackmount enclosure dimensions
Table 16 Operating environmental specifications
HP StorageWorks
Electrical requirements
Site wiring and power requirements
Each enclosure has two power and cooling modules for redundancy. If full redundancy is required, use a separate power source for each module. The AC power supply unit in each power and cooling module is
Power cord requirements
Each enclosure is shipped with two AC power cords that are appropriate for use in a typical outlet in the destination country. Each power cord connects one of the power and cooling modules to an independent, external power source. To ensure power redundancy, connect the two power cords to two separate circuits; for example, to one commercial circuit and one uninterruptible power source (UPS).
64 Environmental requirements and specifications
C Electrostatic discharge
Preventing electrostatic discharge
To prevent damaging the system, be aware of the precautions you need to follow when setting up the system or handling parts. A discharge of static electricity from a finger or other conductor may damage system boards or other
To prevent electrostatic damage:
???Avoid hand contact by transporting and storing products in
???Keep
???Place parts on a grounded surface before removing them from their containers.
???Avoid touching pins, leads, or circuitry.
???Always be properly grounded when touching a
Grounding methods to prevent electrostatic discharge
Several methods are used for grounding. Use one or more of the following methods when handling or installing
???Use a wrist strap connected by a ground card to a grounded workstation or computer chassis. Wrist straps are flexible straps with a minimum of 1 megohm ?? 10 percent resistance in the ground cords. To provide proper ground, wear the strap snug against the skin.
???Use heel straps, toe straps or boot straps at standing workstations. Wear the straps on both feet when standing on conductive floors or dissipating floor mats.
???Use conductive field service tools.
???Use a portable field service kit with a folding
If you do not have any of the suggested equipment for proper grounding, have an authorized reseller install the part.
For more information on static electricity or assistance with product installation, contact an authorized reseller.
HP StorageWorks
66 Electrostatic discharge
D Regulatory compliance and safety
Regulatory compliance
Federal Communications Commission notice
Part 15 of the Federal Communications Commission (FCC) Rules and Regulations has established Radio Frequency (RF) emission limits to provide an
The rating label on the device shows which class (A or B) the equipment falls into. Class B devices have an FCC logo or FCC ID on the label. Class A devices do not have an FCC logo or FCC ID on the label. Once the class of the device is determined, refer to the following corresponding statement.
Class A equipment
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at personal expense.
Class B equipment
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
???Reorient or relocate the receiving antenna.
???Increase the separation between the equipment and receiver.
???Connect the equipment into an outlet on a circuit that is different from that to which the receiver is connected.
???Consult the dealer or an experienced radio or television technician for help.
Declaration of conformity for products marked with the FCC logo, United States only
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
For questions regarding your product, visit http://www.hp.com.
For questions regarding this FCC declaration, contact us by mail or telephone:
???
P.O. Box 692000, Mailstop 510101 Houston, Texas
HP StorageWorks
???
To identify this product, refer to the part, Regulatory Model Number, or product number found on the product.
Modifications
The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by
Cables
Connections to this device must be made with shielded cables with metallic RFI/EMI connector hoods in order to maintain compliance with FCC Rules and Regulations.
Regulatory compliance identification numbers
For the purpose of regulatory compliance certifications and identification, your product has been assigned a unique Regulatory Model Number. The RMN can be found on the product nameplate label, along with all required approval markings and information. When requesting compliance information for this product, always refer to this RMN. The Regulatory Model Number should not be confused with the marketing name or model number of the product.
Regulatory compliance label location
The Regulatory Compliance label for the array is located behind the left ear on the side of the chassis.
Laser device
All HP systems equipped with a laser device comply with safety standards, including International Electrotechnical Commission (IEC) 825. With specific regard to the laser, the equipment complies with laser product performance standards set by government agencies as a Class 1 laser product. The product does not emit hazardous light.
Laser safety warning
WARNING! To reduce the risk of exposure to hazardous radiation:
???Do not try to open the laser device enclosure. There are no
???Do not operate controls, make adjustments, or perform procedures to the laser device other than those specified herein.
???Allow only HP authorized service technicians to repair the laser device.
Certification and classification information
This product contains a laser internal to the fiber optic (FO) transceiver for connection to the Fibre Channel communications port.
In the USA, the FO transceiver is certified as a Class 1 laser product conforming to the requirements contained in the Department of Health and Human Services (DHHS) regulation 21 CFR, Subchapter J. A label on the plastic FO transceiver housing indicates the certification.
Outside the USA, the FO transceiver is certified as a Class 1 laser product conforming to the requirements contained in IEC
68 Regulatory compliance and safety
Laser product label
The optional label in Figure
This optional label indicates that the product is classified as a CLASS 1 LASER PRODUCT. This label may appear on the laser device installed in your product.
Figure
International notices and statements
Canadian notice (avis Canadien)
Class A equipment
This Class A digital apparatus meets all requirements of the Canadian
Cet appareil num??rique de la classe A respecte toutes les exigences du R??glement sur le mat??riel brouilleur du Canada.
Class B equipment
This Class B digital apparatus meets all requirements of the Canadian
Cet appareil num??rique de la classe B respecte toutes les exigences du R??glement sur le mat??riel brouilleur du Canada.
European Union notice
Products bearing the CE marking comply with the EMC Directive (89/336/EEC) and the Low Voltage Directive (73/23/EEC) issued by the Commission of the European Community and if this product has telecommunication functionality, the R&TTE Directive (1999/5/EC).
Compliance with these directives implies conformity to the following European Norms (in parentheses are the equivalent international standards and regulations):
???EN55022 (CISPR 22) - Electromagnetic Interference
???EN55024
???Power Quality:
???
???
???EN60950 (IEC60950) - Product Safety
???Also approved under UL 60950/CSA C22.2 No.
HP StorageWorks
BSMI notice
Japanese notice
Korean notices
Safety
Battery replacement notice
Your computer is equipped with a lithium manganese dioxide, a vanadium pentoxide, or an alkaline internal battery or battery pack. There is a danger of explosion and risk of personal injury if the battery is incorrectly replaced or mistreated. Replacement is to be done by an HP authorized service provider using the HP spare part designated for this product. For more information about battery replacement or proper disposal, contact an HP authorized reseller or HP authorized service provider.
70 Regulatory compliance and safety
WARNING! Yur computer contains an internal lithium manganese dioxide, a vanadium pentoxide, or an alkaline battery pack. There is risk of fire and burns if the battery pack is not properly handled. To reduce the risk of personal injury:
???Do not attempt to recharge the battery.
???Do not expose to temperatures higher than 60??C.
???Do not disassemble, crush, puncture, short external contacts, or dispose of in fire or water.
???Replace only with the HP spare part designated for this product.
Batteries, battery packs, and accumulators should not be disposed of together with the general household waste. To forward them to recycling or proper disposal, please use the public collection system or return them to HP, an authorized HP Partner, or their agents.
For more information about battery replacement or proper disposal, contact an HP authorized reseller or service provider.
Taiwan battery recycling notice
The Taiwan EPA requires dry battery manufacturing or importing firms in accordance with Article 15 of the Waste Disposal Act to indicate the recovery marks on the batteries used in sales, giveaway or promotion. Contact a qualified Taiwanese recycler for proper battery disposal.
Power cords
The power cord set must meet the requirements for use in the country where the product was purchased. If the product is to be used in another country, purchase a power cord that is approved for use in that country.
The power cord must be rated for the product and for the voltage and current marked on the product electrical ratings label. The voltage and current rating of the cord should be greater than the voltage and current rating marked on the product. In addition, the diameter of the wire must be a minimum of
1.00 mm2 or 18 AWG, and the length of the cord must be between 1.8 m (6 ft) and 3.6 m (12 ft). If you have questions about the type of power cord to use, contact an HP authorized service provider.
Route power cords so that they will not be walked on and cannot be pinched by items placed upon or against them. Pay particular attention to the plug, electrical outlet, and the point where the cords exit from the product.
Japanese power cord notice
Electrostatic discharge
To prevent damage to the system, be aware of the precautions you need to follow when setting up the system or handling parts. A discharge of static electricity from a finger or other conductor may damage system boards or other
Preventing electrostatic damage
To prevent electrostatic damage, observe the following precautions:
??? Avoid hand contact by transporting and storing products in
HP StorageWorks
???Keep
???Place parts on a grounded surface before removing them from their containers.
???Avoid touching pins, leads, or circuitry.
???Always be properly grounded when touching a
Grounding methods
There are several methods for grounding. Use one or more of the following methods when handling or installing
???Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis. Wrist straps are flexible straps with a minimum of 1 megohm (??10 percent) resistance in the ground cords. To provide proper ground, wear the strap snug against the skin.
???Use heel straps, toe straps, or boot straps at standing workstations. Wear the straps on both feet when standing on conductive floors or dissipating floor mats.
???Use conductive field service tools.
???Use a portable field service kit with a folding
If you do not have any of the suggested equipment for proper grounding, have an HP authorized reseller install the part.
NOTE: For more information on static electricity, or assistance with product installation, contact your HP authorized reseller.
72 Regulatory compliance and safety
Index
A
accessing the CLI 24
accessing the SMU 39 accumulators 71 audience 11
Avis Canadien, regulatory compliance notice 69
B
batteries
recycling or disposal 71 replacement
notice 70
Taiwan EPA recycling and disposal 71 boot straps, using 72
BSMI, regulatory compliance notice 70
C
cables
FCC compliance statement 28, 63, 68 shielded 28, 63, 68
cabling
connecting controller enclosures to drive enclosures 22
connecting enclosure to data hosts 27 routing requirements 62
cache 19
transportable CompactFlash 19 Canada, regulatory compliance notice 69
certification and classification information, laser 68 Class A equipment, Canadian compliance statement 69 Class B equipment, Canadian compliance statement 69 clearance requirements
using to set controller IP addresses 24 CompactFlash 19
transporting 48 components
Configuration Wizard 41 configuring
direct attach configurations 27 switch attach configurations 28
connecting
controller enclosures to data hosts 27 serial cable to set IP address 24
to remote management hosts 28
connections testing 24
console requirement 62 controller enclosures
connecting to data hosts 27
connecting to remote management hosts 28 conventions
document 11 cord See power cord
CSR See customer self repair 53 current rating 71
customer self repair (CSR) parts catalog 53
D
data hosts
system requirements 27 date and time
changing using SMU 40 declaration of conformity 67
DHCP
obtaining IP addresses 24 direct attach configurations 27 disposal, battery 71
disposal, Taiwan EPA battery 71 dissipating floor mats 72 document
conventions 11 prerequisite knowledge 11 related documentation 11
documentation, HP web site 11
E
electromagnetic compatibility (EMC) 61 electrostatic damage prevention 71 enclosure
cabling 22
IDs, correcting 44
input frequency requirement 64 input voltage requirement 64 powering on 29
site requirements 63 troubleshooting 43
ESD (electrostatic discharge) prevention measures 71 storing products 71 transporting products 71
Ethernet cables requirements 28
European Union, regulatory compliance notice 69
expansion port LED troubleshooting 50
HP StorageWorks 2312fc and 2324fc Modular Smart Array user guide 73
F
faults isolating
a
FCC (Federal Communications Commission) Class A Equipment, compliance notice 67 Class B Equipment, compliance notice 67 declaration of conformity 67 modifications 68
notice 67
Federal Communications Commission See FCC firmware
checking versions 29 when to update 29
floor mats, dissipating 72 found new hardware wizard 27
G
ground strap specifications 72 grounding
suggested equipment for 72
H
hard drive
heel straps, using 72 help, obtaining 12, 13
HP
address for
FCC questions 67 series number 68 storage web site 13
Subscriber???s choice web site 13 technical support 12
telephone number FCC questions 67
humidity operating range 63
I
IDs, correcting for enclosure 44
IEC EMC, worldwide regulatory compliance notice 69 installing enclosures
checklist 21 IP addresses
setting using DHCP 24 setting using the CLI 24
J
Japan
regulatory compliance notice 70
K
Korean, regulatory compliance notice 70
L
label, laser 69 language field 39 laser
international certification and classification information 68
product label 69 radiation, warning 68
regulatory compliance notice 68 LEDs
amber fault conditions 44 Cache Status 35 Enclosure ID 31
Ethernet Activity 34 Ethernet Link Status 34 Fault UID 31 Fault/Service Required 34 front panel 31
hard drive Fault/UID 32 Online/Activity 32
Host Activity 35
Host Link Status/Activity 34 MSA2000 3.5
Fault/Service Required 36 OK 36
OK to Remove 36 SAS In Port Status 36 SAS Out Port Status 36 Unit Locator 36
OK 34
OK to Remove 34 Online/Activity 31 power supply 34 rear panel 34
Unit Identification (UID) 31 Unit Locator 34
using to diagnose fault conditions 44 lithium battery 70
local management host requirement 62 loop topology 27
M
MPIO DSM, obtaining 27 MSA2000 3.5
MSA2000 Family SCSI Enclosure Services (SES) driver 27
O
operating ranges, environmental 63
P
parts
74