HP ProLiant BL
Diagnostic Station
User Guide
Part Number
April 2004 (Fourth Edition)
?? Copyright 2002, 2004
Microsoft and Windows are U.S. registered trademarks of Microsoft Corporation.
Intel and Pentium are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries.
Java is a US registered trademark of Sun Microsystems, Inc.
April 2004 (Fourth Edition)
Part Number
Contents
Abstract
This document provides instructions for cabling the diagnostic station to an
HP ProLiant BL
Diagnostic Station Kit Contents
NOTE: You may need additional items, depending on the server blade you are using.
Figure 1: Diagnostic station kit contents
Table 1: Diagnostic Station Kit Contents
continued
Table 1: Diagnostic Station Kit Contents continued
1For information about connecting the diagnostic station to an interconnect switch using this DC power cord, refer to the documentation that ships with the interconnect switch.
2The AC power cords included with this kit each have a different outlet plug configuration. Be sure to select the proper cord for the electrical service in your facility.
Warnings and Cautions
WARNING: To reduce the risk of shock or injury from
Powering the server blade with the access cover removed is a service operation and must only be performed by trained service personnel.
WARNING: To reduce the risk of shock or injury from
Plug the power cord into a grounded (earthed) electrical outlet that is easily accessible at all times.
CAUTION: Remove all power from the diagnostic station before connecting to the server blade. Disconnect all power cords to completely remove power from the diagnostic station.
CAUTION: Properly ground yourself before beginning any installation procedure. Electrostatic discharge can damage electronic components. For more information about electrostatic discharge, refer to the setup and installation guide.
CAUTION: Disconnect the local I/O cable when not in use. The port and connector do not provide a permanent connection. Rear iLO connector performance degrades when the local I/O cable is in use, even when the iLO connector on the cable is not in use.
Using the Diagnostic Cable or the Local I/O Cable for Configuration or Diagnostic Procedures
Use either the diagnostic cable or the local I/O cable to perform some server blade configuration and diagnostic procedures. Depending on the model, the server blade will have either a diagnostic port or an I/O port. The I/O port only accepts the local I/O cable and the diagnostic port only accepts the diagnostic cable. If the server blade has an I/O icon next to the port on the front of the server blade, use the local I/O cable. If the port has no icon, use the diagnostic cable. Refer to Figure 2 to identify the I/O icon.
Figure 2: Local I/O cable with large view of the I/O icon
Identifying Diagnostic and Local I/O Cable Connectors
Use Figure 3 and Table 2 to identify diagnostic cable and local I/O cable connectors.
Figure 3: Diagnostic cable (top) and local I/O cable (bottom) connectors
Table 2: Diagnostic and Local I/O Cable Connectors
Provides a 10/100 Ethernet
1 A standard Ethernet cable can be used with the
continued
Table 2: Diagnostic and Local I/O Cable Connectors continued
perform advanced diagnostic procedures.
Provides a 10/100 Ethernet
1A standard Ethernet cable can be used with the
2The kernel debug connector does not function as a serial port.
3The local I/O cable is labeled with the I/O icon. The diagnostic cable has no label.
Installing the Diagnostic Cable or the Local I/O Cable
To install the diagnostic cable or the local I/O cable with the diagnostic station, see the ???Diagnostic Station??? section.
To install the diagnostic cable on a server blade in the rack, refer to the setup and installation guide included with the server blade.
Diagnostic Station
The diagnostic station enables you to power up and communicate with a server blade or an interconnect switch outside of the rack environment.
Overview
The diagnostic station enables you to perform the following tasks outside of the rack:
NOTE: An additional power supply may be required for some ProLiant
???Power up a server blade or interconnect switch.
???Observe external LEDs.
???Test NIC activity.
???Configure a server blade or interconnect switch.
???Load software on a server blade or interconnect switch.
???Test a server blade or interconnect switch after installing an option or upgrade.
???Diagnose a server blade or interconnect switch problem using iLO or connecting directly to the server blade.
IMPORTANT: The diagnostic station is not designed to function as a continuous power supply replacement.
IMPORTANT: The ProLiant BL30p blade sleeve is required when powering a ProLiant BL30p server blade outside of the rack. Only one ProLiant BL30p server blade may be installed in the blade sleeve when receiving power from the diagnostic station.
For more information about installing hardware options and performing troubleshooting procedures, refer to the
Diagnostic Station Components
Use Figure 4 and Table 3 to identify diagnostic station components.
Figure 4: Diagnostic station components
Table 3: Diagnostic Station Components
Item Component Description
1
2
3
4
continued
Table 3: Diagnostic Station Components continued
Item Component Description
5Reserved for additional AC power
6AC power input connector
7DC power output connectors
8Data transfer port
9NIC LEDs
10Power On/Off button
11Power and health LED
*This component does not apply to the ProLiant BL30p server blade.
Accessing the Cable Storage Area
To access the cable storage area:
1.Turn the locking latch clockwise (1).
2.Pull down the cable storage area access door (2).
Figure 5: Accessing the cable storage area
Client PC Requirements
Observe the following minimum software and hardware requirements for a client PC:
???Intel?? Pentium?? III or higher processor (700 MHz or greater recommended)
???128 MB of RAM
???Microsoft?? Windows?? 2000 Professional or Microsoft Windows XP operating system
???Microsoft Internet Explorer 5.5 or above with
???Ethernet NIC with 10/100
???TCP/IP networking and an IP address compatible with one of the following:
???iLO diagnostic port static IP address: 192.168.1.1, mask 255.255.255.0
???Assigned DHCP or static IP address
???Any of the following Java??? Runtime Environment versions:
???1.3.1_02
???1.3.1_07
???1.3.1_08
???1.4.1 for Windows users only
???1.4.2 for Linux users only
Access the Java Runtime Environment versions at
http://java.sun.com/products/archive/index.html
Server Blade
Use the following information to connect the diagnostic station to a server blade.
Preparing the Server Blade for Connection
Before connecting the diagnostic station to a server blade:
1.Power down the server blade.
2.Remove the server blade from the server blade enclosure in the rack.
IMPORTANT: If the server blade is a ProLiant BL30p, install the server blade into a blade sleeve and connect the blade sleeve to a diagnostic station.
3.Place the server blade on a flat, level workspace.
4.Perform any upgrade or maintenance actions and replace the access panel.
Cabling the Diagnostic Station to a Server Blade
This document provides two methods for connecting the diagnostic station to a server blade:
???Direct cabling method???Use either method to be sure an option is correctly installed in the server blade. This method is recommended for installing an operating system on a server blade. The connection can be made in one of two ways:
???With a client
CAUTION: Disconnect the local I/O cable when not in use. The port and connector do not provide a permanent connection. Rear iLO connector performance degrades when the local I/O cable is in use, even when the iLO connector on the cable is not in use.
???With USB
NOTE: Use of the USB hub is optional as the hub is only required when connecting three or more USB devices. For example, you may connect a monitor to the video connector and a USB mouse and USB keyboard to the USB connector.
???Network cabling method???Use this method to mimic a network environment and to perform server blade configuration or advanced troubleshooting. In this method, the client PC is connected to the iLO using a hub/switch and the network connections of the diagnostic station. The iLO default configuration enables the server blade to obtain its IP address from a DHCP server.
Using the Direct Cabling Method with a Client PC
NOTE: Items in addition to those provided with the diagnostic station may be required. Additional items will be noted in the option kits they ship with.
NOTE: The server blade in the illustrations may look different from the model you are using.
WARNING: To avoid electric shock, be sure that the AC power is disconnected from the diagnostic station when connecting cables to the server blade.
To connect a client PC to the server using the direct cabling method:
1.Thread the DC power cord for a server blade or blade sleeve through the opening in the VHDM converter (1).
2.Snap the cord into place in the VHDM converter (2).
Figure 6: Threading the DC power cord through the
VHDM converter
3.Place the VHDM converter on the rear of the server blade or the blade sleeve by inserting the tab into the right side (1), making sure the pins on the left side are properly aligned.
4.Tighten the thumbscrew to secure the VHDM converter to the server blade (2) or the blade sleeve.
5.Insert the DC power cord into one of the diagnostic station DC power connectors (3).
Figure 7: Attaching the VHDM converter and connecting the DC power cord
6.Connect the data transfer cable to the VHDM converter on the server blade (1) or the blade sleeve.
7.Connect the other end of the data transfer cable to the diagnostic station (2).
Figure 8: Connecting the data transfer cable
8.Connect the server blade to the client PC using the diagnostic cable. If you are using the local I/O cable to connect to the I/O port, go to step 9.
CAUTION: Disconnect the diagnostic cable when not in use. The port and connector do not provide a permanent connection. Rear iLO connector performance degrades when the local I/O cable is in use, even when the iLO connector on the cable is not in use.
a.Connect the network cable with
b.Connect the other end of the
c.Connect the diagnostic cable to the diagnostic port on the front of the server blade (3).
d.Go to step 10.
Figure 9: Connecting the server blade to a client PC using the diagnostic cable
9. Connect the server blade to a client PC using the local I/O cable.
CAUTION: Disconnect the local I/O cable when not in use. The port and connector do not provide a permanent connection. Rear iLO connector performance degrades when the local I/O cable is in use, even when the iLO connector on the cable is not in use.
a.Connect the network cable with
b.Connect the other end of the
c.Connect the local I/O cable to the I/O port on the front of the server blade (3).
Figure 10: Connecting the server blade to a client PC using the local I/O cable
IMPORTANT: If you are connecting to a ProLiant BL30p server blade, the server blade must be installed in the left slot of the blade sleeve on a flat surface.
Figure 11: Connecting the ProLiant BL30p server blade to a client PC using the local I/O cable
IMPORTANT: The diagnostic station ships with several AC power cords of different outlet plug configurations. Be sure to select the proper AC power cord for the electrical service.
10.Connect the AC power cord to the diagnostic station (1).
11.Connect the other end of the AC power cord to an AC outlet (2).
NOTE: Previously installed components have been removed for clarity.
Figure 12: Connecting the AC power cord
NOTE: Depending on which server blade you are using, you may need to install a second power supply in the diagnostic station. A second power cord would also be required.
Refer to Figure 13 for the completed direct cabling method using diagnostic cable (left) and the local I/O cable (right).
Figure 13: Completed direct cabling method (front and rear views) using the diagnostic cable (1) and the local I/O cable (2) to connect to iLO
After the direct cabling method is complete, the server blade and diagnostic station are ready for use. See the ???Powering Up the Server Blade??? section.
IMPORTANT: Before removing the local I/O cable, completely log out of the current iLO session. Do not remove the local I/O cable when the Unit Identification (UID) LED is blinking.
Using the Direct Cabling Method with USB Devices
Use the following setup to configure a server blade using a SmartStart CD or to load software updates and patches using the
Connect to the server using the direct cabling method with USB devices:
1.Follow steps 1 through 7 of ???Using the Direct Cabling Method with a Client PC??? to make connections from the server blade to the Diagnostic Station.
2.Connect the server blade connector on the local I/O cable to the server blade.
CAUTION: Disconnect the local I/O cable when not in use. The port and connector do not provide a permanent connection. Rear iLO connector performance degrades when the local I/O cable is in use, even when the iLO connector on the cable is not in use.
3.Connect the monitor to the video connector on the local I/O cable.
4.Connect a USB hub to the USB connector on the local I/O cable.
NOTE: Use of the USB hub is optional as you may connect to the server using any combination of USB devices. For example, you may connect a monitor to the video connector and a USB mouse and USB keyboard to the USB connector.
5.Connect the following to the USB hub:
a.USB
b.USB keyboard
c.USB mouse
Refer to Figure 14 for the completed direct cabling method using USB devices and the local I/O cable.
Figure 14: Completed direct cabling method (front and rear view) using the local I/O cable and USB devices to directly access the server blade
After the direct cabling method is complete, the server blade and diagnostic station are ready for use. See the ???Powering Up the Server Blade??? section.
Using the Network Cabling Method
In addition to the diagnostic station and contents, you need to supply the following items:
???Client PC (See the ???Client PC Requirements??? section for minimum software and hardware requirements.)
???Additional network cable with
???Hub/switch
???Deployment server or file server (optional) for operating system deployment or file management (may be the same physical server as the DHCP server)
???DHCP server
IMPORTANT: The DHCP server assigns the IP address to the iLO NIC. The DHCP server is not necessary if you have configured iLO and/or any other connected NICs to use a static IP address.
To connect with the network cabling method:
1.Follow steps 1 through 7 of ???Using the Direct Cabling Method with a Client PC??? to make the connections from the server blade to the diagnostic station.
WARNING: To avoid electric shock, be sure that the AC power is disconnected from the diagnostic station when connecting cables to the server blade.
2.Connect the network cable with
3.Connect the AC power cord to the diagnostic station (3).
NOTE: Previously installed components have been removed for clarity.
Depending on which server blade you are using, you may need to install a second power supply in the diagnostic station. A second power cord would also be required.
Figure 15: Connecting a network cable and the AC power cord to the diagnostic station
IMPORTANT: If you are using the diagnostic station for operating system deployment or file management, connect an additional network cable with
4.Connect an additional network cable with
Figure 16: Connecting a network cable to the client PC and the hub
5.Connect the following items to the hub:
a.Network cable with
b.Network cable with
c.DHCP server (optional), if not already connected
d.Network cable with
e.Deployment server or file server (optional)
6.Connect the diagnostic station AC power cord to an AC outlet.
Figure 17 shows a completed network cabling method with the DHCP server (1) and the hub (2).
IMPORTANT: For operating system deployment or file management, an optional server can be connected to the hub.
NOTE: Connecting the diagnostic cable to the diagnostic port or connecting the local I/O cable to the I/O port automatically disables the iLO connection on the rear of the diagnostic station.
Figure 17: Completed network cabling method
NOTE: Your completed configuration may look different, depending on which server blade you are using.
After the network cabling method is complete, the server blade and diagnostic station are ready for use. See the ???Powering Up the Server Blade??? section.
Powering Up the Server Blade
To power up the server blade:
1.Power up the diagnostic station by pressing the Power On/Off button.
2.Power up the server blade.
3. Power up the client PC in accordance with its own documentation.
NOTE: iLO may take up to 90 seconds to establish a secure network connection.
IMPORTANT: If tasks are to be performed on more than one ProLiant BL30p server blade, power down the first server blade and remove it from the blade sleeve. Then, install the next server blade in the left bay of the blade sleeve when the blade sleeve is laying on a flat surface.
iLO Guidelines for Accessing the Server Blade
Use the following guidelines when you prepare to access the server blade with the iLO Remote Console for the first time.
Two cabling methods are available to make the wiring connections from the client PC to the iLO: the direct cabling method and the network cabling method.
NOTE: Refer to the setup and installation guide for the server blade you are using for information on accessing the server blade with the iLO Remote Console.
NOTE: If using the
IMPORTANT: Before removing the local I/O cable, completely log out of the current iLO session. Do not remove the local I/O cable when the UID LED is blinking.
Direct Cabling Method
In this method, the client PC is connected to the iLO using the diagnostic port or the I/O port on the front of the server blade. This is a direct,
Network Cabling Method
In this method, the client PC is connected to the iLO using a hub/switch and the network connections of the diagnostic station. The iLO default configuration enables the server blade to obtain its IP address from a DHCP server.
NOTE: If you have edited the configuration to use a static IP address, iLO uses this same static IP address when you connect with the network cabling method.
Connection Information and Browser Compatibility
To access iLO, you need some basic connection information:
???The TCP/IP address or DNS/WINS name of the iLO
???When using the direct cabling method, use the 192.168.1.1 for the TCP/IP address and 255.255.255.0 for the subnet mask.
???When using the network cabling method, look on the iLO Default Network Settings tag for first time access.
???A valid user ID and password with appropriate iLO privileges for accessing Remote Console
This information is also available on the iLO Default Network Settings tag for initial access information.
Be sure that the IP address and subnet mask of the client PC are compatible with the IP address and subnet mask of the iLO diagnostic port. In addition, be sure that the browser bypasses any proxy servers for the IP address or DNS/WINS name of the iLO.
GbE Interconnect Switch
You can configure or troubleshoot a GbE interconnect switch in an
???Diagnostic station
???DC power cord (for interconnect switch)
???Network cable with
???AC power cord
For setup and operating instructions, refer to the documentation that ships with the interconnect switch.
Regulatory Compliance Notices
Regulatory Compliance Identification Numbers
For the purpose of regulatory compliance certifications and identification, your product has been assigned a unique HP series number. The series number can be found on the product nameplate label, along with all required approval markings and information. When requesting compliance information for this product, always refer to this series number. The series number should not be confused with the marketing name or model number of the product.
Federal Communications Commission Notice
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at personal expense.
Modifications
The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by
Cables
Connections to this device must be made with shielded cables with metallic RFI/EMI connector hoods in order to maintain compliance with FCC Rules and Regulations.
Canadian Notice
This Class A digital apparatus meets all requirements of the Canadian Interference- Causing Equipment Regulations.
Avis Canadien
Cet appareil num??rique de la classe A respecte toutes les exigences du R??glement sur le mat??riel brouilleur du Canada.
European Union Notice
Products bearing the CE marking comply with the EMC Directive (89/336/EEC) and the Low Voltage Directive (73/23/EEC) issued by the Commission of the European Community and if this product has telecommunication functionality, the R&TTE Directive (1999/5/EC).
Compliance with these directives implies conformity to the following European Norms (in parentheses are the equivalent international standards and regulations):
???EN 55022 (CISPR 22) ??? Electromagnetic Interference
???EN55024
???
???
???EN 60950 (IEC 60950) ??? Product Safety
Japanese Notice
Korean Notice
BSMI Notice