Repair
Drywall Feed Pump
- For
- Not for use in explosive atmospheres - - Not for use with
READ ALL WARNINGS AND INSTRUCTIONS
Read all warnings and instructions in this manual.
Save these instructions.
Maximum Working Pressure 2500 psi (17.2 MPa, 172 bar)
Model 257100: 120V NA ETL Listed
Model 258906: 240V Euro Multicord
Model 258907: 110V UK, CE
Model 262288: 120V NA
Model 262300: 240V Euro CE Cord
Agency Approvals:
ti14873a
Warning
Warning
The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbols refer to
WARNING
ELECTRIC SHOCK HAZARD
This equipment must be grounded. Improper grounding, setup, or usage of the system can cause electric shock.
???Turn off and disconnect power cord before servicing equipment.
???Use only grounded electrical outlets.
???Use only
???Ensure ground prongs are intact on power and extension cords.
???Do not expose to rain. Store indoors.
SKIN INJECTION HAZARD
??? Engage trigger lock when not dispensing.
???Do not point dispensing device at anyone or at any part of the body.
???Do not put your hand over the fluid outlet.
???Do not stop or deflect leaks with your hand, body, glove, or rag.
???Follow the Pressure Relief Procedure when you stop dispensing and before cleaning, checking, or servicing equipment.
???Tighten all fluid connections before operating the equipment.
???Check hoses and couplings daily. Replace worn or damaged parts immediately.
FIRE AND EXPLOSION HAZARD
Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion:
??? Do not dispense flammable or combustible materials near an open flame or sources of ignition such as cigarettes, motors, and electrical equipment.
??? Material or solvent flowing through the equipment is able to result in static electricity. Static electricity creates a risk of fire or explosion in the presence of material or solvent fumes. All parts of the system, including the pump, hose assembly, dispenser, and objects in and around the work area shall be properly grounded to protect against static discharge and sparks. Use Graco conductive or grounded
???Verify that all containers and collection systems are grounded to prevent static discharge.
???Connect to a grounded outlet and use grounded extensions cords. Do not use a
???Do not use a material or a solvent containing halogenated hydrocarbons.
???Keep work area
???Do not smoke in the work area.
???Do not operate light switches, engines, or similar spark producing products in the work area.
???Keep area clean and free of material or solvent containers, rags, and other flammable materials.
???Know the contents of the materials and solvents being dispensed. Read all Material Safety Data Sheets (MSDS) and container labels provided with the materials and solvents. Follow the material and solvents manufacturer???s safety instructions.
???Fire extinguisher equipment shall be present and working.
???Drywall feed pump generates sparks. When flammable liquid is used in or near the drywall feed pump or for flushing or cleaning, keep unit at least 20 feet (6 m) away from explosive vapors.
Warning
WARNING
MOVING PARTS HAZARD
Moving parts can pinch, cut or amputate fingers and other body parts.
???Keep clear of moving parts.
???Do not operate equipment with protective guards or covers removed.
???Pressurized equipment can start without warning. Before checking, moving, or servicing equipment, follow the Pressure Relief Procedure and disconnect all power sources.
EQUIPMENT MISUSE HAZARD
Misuse can cause death or serious injury.
???Always wear appropriate gloves, eye protection, and a respirator or mask when dispensing.
???Do not operate or dispense near children. Keep children away from equipment at all times.
???Do not overreach or stand on an unstable support. Keep effective footing and balance at all times.
???Stay alert and watch what you are doing.
???Do not leave the unit energized or under pressure while unattended. When the unit is not in use, turn off the unit and follow the Pressure Relief Procedure for turning off the unit.
???Do not operate the unit when fatigued or under the influence of drugs or alcohol.
???Do not kink or
???Do not expose the hose to temperatures or to pressures in excess of those specified by Graco.
???Do not use the hose as a strength member to pull or lift the equipment.
PRESSURIZED ALUMINUM PARTS HAZARD
Use of fluids that are incompatible with aluminum in pressurized equipment can cause serious chemical reaction and equipment rupture. Failure to follow this warning can result in death, serious injury, or property damage.
???Do not use
???Many other fluids may contain chemicals that can react with aluminum. Contact your material supplier for compatibility.
PERSONAL PROTECTIVE EQUIPMENT
You must wear appropriate protective equipment when operating, servicing, or when in the operating area of the equipment to help protect you from serious injury, including eye injury, hearing loss, inhalation of toxic fumes, and burns. This equipment includes but is not limited to:
???Protective eyewear, and hearing protection.
???Respirators, protective clothing, and gloves as recommended by the fluid and solvent manufacturer.
Pressure Relief Procedure
Pressure Relief Procedure
1.Turn flow control knob to fully counterclockwise to OFF position.
3.Turn prime valve handle to PRESSURE RELIEF position.
bar/psi ti15614a
4. Display will read
ti8793a
2. Place deflector in hopper or suitable container.
ti14876a
Drive and Bearing Housing
NOTICE
Do not drop gear cluster (17a) when removing drive housing (5a). Gear cluster may stay engaged in motor front end bell or drive housing.
Removal
1.Perform Pressure Relief Procedure, page 4.
2.Remove Power Module, see page 7.
3.Remove Pump, page 8.
4.Remove four screws (40) and lift motor shroud (98) off of motor.
40
98
ti15624a
5.Disconnect three wire harnesses (see Wiring Diagrams, pages
Drive and Bearing Housing
6.Remove two screws (5b) from underneath motor base plate. Lift and remove motor/pump assembly from power module.
5b
ti11734a
7.Loosen four screws (19) on pump housing, and remove bearing housing (9) from motor.
9
ti15630a
19
8.Remove three screws (5c) on motor (8a). Remove motor (8a) from drive housing (5a).
8a
5a
5c
ti11735a
Drive and Bearing Housing
Installation
1.Apply brown lithium grease supplied with drive housing kit (5) to gear cluster (17a) and inside of motor cavity.
5a
2.Align orientation tab on gear housing with slot on motor and slide gears into motor.
3.Replace and tighten three screws (5c) on motor (8a). Torque to
5c
8a
ti11735a
4.Attach bearing housing (9) to gear housing (5a) (slowly turn motor fan by hand to align gear into pump connecting rod). Torque four bearing housing screws (19) to
5a
9
ti15630a
19
5.Replace motor/pump assembly into pump module. Replace and tighten two screws (5b) underneath motor base plate. Torque to 200 - 220
5b
ti11734a
6.Reconnect three wire harnesses (see Wiring Diagrams, pages
7.Replace motor shroud (98) and tighten four screws (40). Torque to
40
98
ti15624a
8.Replace Pump, page 8.
9.Replace Power Module, see page 7.
Power Module
Removal
1.Perform Pressure Relief Procedure, see page 4. Unplug power cord.
2.Release hopper adapter clamp (158).
158
ti15684a
3.Loosen rod clamp knob (112) on front of pump mod- ule and push rod down.
112
ti11675a
4.Lift and pull power module (153) off of unit. NOTE: Power module weighs approximately 85 lb.
153
ti15623a
5. Install hopper plug (117) if needed.
Power Module
Installation
1.Remove hopper plug (117) if installed.
2.Replace power (153) module and insert pump outlet into hopper inlet.
153
ti15625a
3.Pull rod clamp up and tighten knob (112) on front of pump module.
112
ti11678a
4. Fasten hopper adapter clamp (158).
158
ti15683a
117
ti15623a
Pump
Pump
Removal
1.Perform Pressure Relief Procedure, see page 4.
2.Remove Power Module, see page 7.
3.Disconnect material hose (79) from pump (18a).
79
18a
ti15616a
4.Loosen two screws (40) and remove pump rod shield (48).
40
48
ti15619a
5.Turn flow control knob to a very low setting and turn prime valve handle to TOOL FILL position (JOG mode will appear in display). Use ON/OFF switch or turn control knob OFF to stop pump when pin is visible.
ti15620a
6.Use screwdriver to press pin (7b) out of pump. 7b
ti15617a
NOTE: Pin should be removed by pressing the pin out through the bottom side of the pump. Make sure to control the pump pin when removing so that it does not fall into the pump module.
7. Use hammer to loosen pump retaining nut (22).
22
ti15615a
8. Unscrew and remove pump (18a) from module.
18a
ti15618a
Installation
1. Extend pump piston rod 1.5 in.
1.5 in.
ti7171a
2.Install pump pin (7b). Verify retaining spring is in groove of connecting rod.
7b
ti13093a
NOTE: Pin should be installed from the top side of the pump. Make sure to control the pump pin when installing so that it does not fall into the pump module.
3. Push pump up until pump threads engage.
Pump
7.Replace pump rod shield (48) and torque two screws (40) to 30 - 34
40
48
ti15924a
4.Screw in pump until threads are flush with drive housing opening.
ti15621a
5.Align pump outlet to right side so that hose can be reassembled.
ti15923a
6.Screw jam nut up toward drive housing until nut stops. Tighten jam nut by hand, then tap 1/8
to 1/4 turn with a 20 oz. (maximum) hammer to approximately 75?? 5
ti15925a
ti15619a
8. Reconnect material hose (79) to pump (18a).
79
18a
ti15616a
9. Replace Power Module, see page 7.
Motor
Motor
Removal
1.Perform Pressure Relief Procedure, see page 4.
2.Remove Power Module, see page 7.
3.Disconnect material hose (79) from pump (18a).
7.Loosen four screws (19) on bearing housing (9), and remove from gear housing.
5a
9
ti15630a
19
8.Remove three screws (5c) on motor (8a). Remove motor from gear housing.
ti15616a
79
18a
5c
4.Remove four screws (40) and lift motor shroud (98) off of motor.
40
98
ti15624a
5.Disconnect three wire harnesses (see Wiring Diagrams, pages
6.Remove two screws (5b) from underneath motor base plate. Lift and remove motor/pump assembly from pump module.
5b
ti11734a
8a
ti11735a
Installation
1.Apply brown lithium grease supplied with motor repair kit (8) to gear cluster (17a) and inside of motor cavity.
2.Align orientation tab on gear housing with slot on motor and slide gears into motor.
3.Replace three screws (5c) on motor (8a). Torque to
5a
5c
8a
ti11735a
4.Attach bearing housing (9) to gear housing (5a) (slowly turn motor fan by hand to align gear into pump connecting rod). Torque four bearing housing screws (19) to
5a
9
ti15630a
19
5.Replace motor/pump assembly into pump module. Replace and torque two screws (5b) underneath motor base plate to 200 - 220
Motor
7.Replace motor shroud (98) and torque four screws (40) to 30 - 34
40
98
ti15624a
8. Reconnect material hose (79) to pump (18a).
5b
ti11734a
ti15616a
79
18a
9. Replace Power Module, see page 7.
Motor Control Board
Motor Control Board
Removal
120V Models:
1.Perform Pressure Relief Procedure, see page 4. Wait 5 minutes before servicing.
2.Remove Power Module, see page 7.
3.Disconnect material hose (79) from pump (18a).
6.Disconnect display connector (A) from motor control board (24) and remove display.
ti13569a
24
A
7.Remove bottom two screws (61) and remove control panel (37).
ti15616a
79
18a
37
61
ti15795a
4.Remove four screws (40) and lift motor shroud (98) off of motor.
40
98
ti15624a
5. Remove four screws (33b) and display cover (33k).
33k
24
E
ti13572a
9.Disconnect potentiometer connector (C) from motor control board (24).
24
ti15791a
C
10.Disconnect 15/20A switch connector (X) from motor control board (24).
24
X
ti15850a
11.Disconnect white power cord conductor (D) from motor control board (24).
Motor Control Board
16.Disconnect three motor connectors from motor con- trol board to motor.
24
ti15851a
D
12.Disconnect black power lead (J) on motor control board (24) from ON/OFF switch.
J
ti15849a
13.Remove ground screw (58) from motor control board/heat sink assembly.
58
ti15846a
14. Remove two top screws (61) and control box (3).
61
3
ti15912a
15.Disconnect transducer connector from motor control board (24).
ti12999a
24
ti15847a
17.Remove two screws (83) holding motor control board /heat sink assembly to power module frame. Remove motor control board/heat sink assembly.
83
ti15845a
18.Remove six outer screws, two inner screws, and remove control board (24) from heat sink.
24
ti15844a
Motor Control Board
110 UK and 240V Models:
1.Perform Pressure Relief Procedure, see page 4. Wait 5 minutes before servicing.
2.Remove Power Module, see page 7.
3.Disconnect material hose (79) from pump (18a).
7. Remove bottom two screws (61) control panel (37).
37
61
ti15795a
ti15616a
79
18a
8.Disconnect Prime/Tool Fill/Recirculate reed switch connector (E) from motor control board (24).
24
4.Remove four screws (40) and lift motor shroud (98) off of motor.
40
98
E
ti13572a
ti15624a
5. Remove four screws (33b) and display cover (33k).
33k
6.Disconnect display from motor control board (24) and remove display.
24
ti13569a
9.Disconnect potentiometer connector (C) from motor control board (24).
24
ti15791a
C
10.Disconnect black power lead (G) from motor control board to filter board. Disconnect blue power lead (B) from motor control board to filter board.
G
B
ti15848a
11.Remove ground screw (58) from motor control board/heat sink assembly.
58
ti15846a
12. Remove top two screws (61) and control box (3).
61
3
ti15912a
13.Disconnect transducer connector from motor control board (24).
ti12999a
24
14.Disconnect three motor connectors from motor con- trol board to motor.
ti15847a
Motor Control Board
15.Remove two screws (83) holding motor control board / heat sink assembly to power module frame. Remove motor control board/heat sink assembly.
83
ti15845a
16.Remove six outer screws, two inner screws, and remove control board (24) from heat sink.
24
ti15844a
Motor Control Board
Installation
120V Models:
1.Use acetone or equivalent cleaner to thoroughly remove thermal paste from pockets on heat sink.
ti14695a
2.Apply new thermal paste into both pockets of heat sink.
ti14693a
3.Replace two inner screws and washers to control board and torque to 17
ti15926a
4.Replace six outer screws to control board and torque to 11
ti14697a
NOTE: SW1 position setting does not matter.
5.Connect motor control board lead connectors (F) to leads from motor. Insert grommet in heat sink baffle. Use zip tie or electrical tape (Z) to hold grommet together on grommet end on the motor side of the heat sink.
Z
F
ti15852a
6. Assemble gasket (94) to heat sink assembly.
94
ti15911a
7.Assemble two screws (83) to hold motor control board/ heat sink assembly to power module frame. Torque to
83
ti15845a
8.Assemble ground screw (58) to heat sink. Torque to
58
ti15846a
9.Assemble control box enclosure (3) to power mod- ule and tighten two screws (61). Torque to
61
3
ti15912a
10.Connect black power lead (J) on motor control board to ON/OFF switch.
Motor Control Board
15.Replace control panel (37) and tighten bottom two screws (61). Torque to
J
ti15849a
11.Connect white power cord conductor (D) to motor control board (24).
24
ti15851a
D
12.Connect 15/20A switch connector (X) to motor con- trol board (24).
24
X
ti15850a
13.Connect potentiometer connector (C) to motor con- trol board (24).
24
ti15791a
C
14.Connect Prime/Tool Fill/Recirculate reed switch con- nector (E) to motor control board (24).
37
61
ti15795a
16.Connect display connector to motor control board (24).
ti13569a
24
17.Assemble display cover (33k). Spring tabs on noise shield need to be assembled to the inside of the control box enclosure. Torque screws (33b) to
33k
18.Remove four screws (40) and lift motor shroud (98) off of motor.
40
98
ti15624a
19. Disconnect material hose (79) from pump (18a).
24
E
ti13572a
ti15616a
79
18a
20. Replace Power Module, see page 7.
Motor Control Board
110 UK and 240V Models:
1.Use acetone or equivalent cleaner to thoroughly remove thermal paste from pockets on heat sink.
ti14695a
2.Apply new thermal paste into both pockets of heat sink.
ti14693a
3.Replace two inner screws and washers to control board and torque to 17
ti15926a
4.Replace six outer screws to control board and torque to 11
ti14697a
NOTE: SW1 position setting does not matter.
5.Connect motor control board lead connectors (F) to leads from motor. Insert grommet in heat sink baffle. Use zip tie or electrical tape (Z) to hold grommet together on grommet end on the motor side of the heat sink.
Z
F
ti15852a
6. Assemble gasket (94) to heat sink assembly.
94
ti15911a
7.Assemble two screws (83) to hold motor control board/ heat sink assembly to power module frame. Torque to
83
ti15845a
8.Assemble ground screw (58) to heat sink. Torque to
58
ti15846a
9.Assemble control box enclosure (3) to power mod- ule using two top screws (61). Torque to
61
3
ti15912a
10.Connect blue (B) and black (G) power leads from motor control board (24) to filter board.
G
B
ti15848a
11.Connect potentiometer connector (C) to motor con- trol board (24).
24
ti15791a
C
12.Connect Prime/Tool Fill/Recirculate reed switch con- nector (E) to motor control board (24).
24
E
ti13572a
13.Replace control panel (37) and tighten bottom two screws (61). Torque to
37
Motor Control Board
15.Assemble display cover (33k). Spring tabs on noise shield need to be assembled to the inside of the control box enclosure. Torque screws to
33k
ti15786a
16.Replace motor shroud (98) and torque four screws (40) to 30 - 34
40
98
ti15624a
17. Reconnect material hose (79) to pump (18a).
ti15795a
61
14.Connect display connector to motor control board (24).
ti15616a
79
18a
ti13569a
24
18. Replace Power Module, see page 7.
Prime Valve Handle
Prime Valve Handle
Removal
1.Perform Pressure Relief Procedure, see page 4. Wait 5 minutes before servicing.
2.Use 3/32 in. punch and hammer to tap out handle pin (72c) (pliers may be required to pull out handle pin). Pull off handle (72a) and base (72b).
3.Use crescent wrench to unscrew prime valve (71).
NOTE: Make sure that the seat and gasket are removed from the manifold.
71
72c
72a
72b
4.Clear out any material that is lodged in valve (71) or manifold (70).
Installation
1.Tighten prime valve (71) into manifold (70). Use thread sealant on housing threads and torque to 190 to 210
2.Install prime valve base (72b). Pin in base must align with hole in manifold (70).
3.Orient hole in prime valve stem (71) vertically.
4.Place prime valve handle (72a) over prime valve base (72b) with handle in ???apply??? mode. Align hole in handle (72a) w/hole in prime valve stem (71).
5.Use hammer to tap prime valve handle pin (72c) back into place.
70
ti15633a
Pressure Transducer
Pressure Transducer
Removal
1.Perform Pressure Relief Procedure, see page 4. Wait 5 minutes before servicing.
2.Remove four screws (33b) and cover (33k).
33k
3.Disconnect transducer connector (E) from motor control board (24).
5.Remove four screws (61) and control box (3). Allow control panel (37) to hang down freely.
3
37
61
6. Remove grommet (23) from control box (3).
23
3
ti15785a
7.Remove transducer (39) and
70
24
E
ti12999a
23
39
50
ti15788a
Installation
4.Disconnect potentiometer connector (D) and reed switch connector (87) from motor control board (24).
24 D
87
ti15792a
1.Install
70
23
39
50
ti15793a
ti15783a
3
Pressure Transducer
2.Connect transducer connector (E) and reed switch connector to control board (24).
5.Connect display connector (A) to motor control board (24).
24
E
ti12999a
24
ti13569a
A
3.Install control box (3) and control panel (37) with four screws (61). Torque to 30 - 35
4.Connect potentiometer connector (D) and reed switch connector (87) to control board (24).
24 D
87
ti15792a
6.Install cover (33k) with four screws (33b). Torque to
33k
ti15786a
33b
Flow Control Adjust
Potentiometer
Removal
Flow Control Adjust Potentiometer
6.Remove gasket (56), nut, spacer (88) and potenti- ometer (55) from control panel (37).
55
56
Installation
37
ti15786a
33k
1.Install gasket (56), nut, spacer (88) and potentiome- ter (55) on control panel (37). Torque nut to
55
33b
56
37
3.Remove bottom two screws (61) and remove control panel (37).
37
61
ti15795a
4.Disconnect potentiometer connector (D) from motor control board (24).
24
ti15791a D
5. Use hex wrench to remove control knob (42).
42
ti7258a
2.Install control knob (42): Check control knob align- ment to potentiometer shaft. Turn shaft fully clock- wise and attach knob in full ON position with a hex wrench. Make sure set screw is tightened flat against potentiometer shaft.
42
ti13338a
3.Connect potentiometer connector (D) to motor con- trol board (24).
24
D
ti15791a
Flow Control Adjust Potentiometer
4.Replace control panel (37) and tighten bottom two screws (61). Torque to
37
61
ti15795a
5.Connect display connector (A) to motor control board (24).
24
ti13569a
A
6.Install cover (33k) with four screws (33b). Torque to
33k
Prime/Tool Fill/Recirculation Reed Switch
Prime/Tool Fill/Recirculation Reed Switch
1.Perform Pressure Relief Procedure, see page 4. Wait 5 minutes before servicing.
2.Remove four screws (33b) and remove display cover (33k).
33k
ti15786a
33b
3.Remove bottom two screws (61) and remove control panel (37).
37
1.Apply thread sealant to end of reed switch (87).
37
87
ti13574a
2.Add thread sealant and tighten jam nut against threaded bus.
ti13576a
3. Connect reed switch (87) to control board (24).
24
87
ti13572a
61
ti15795a
4. Unplug reed switch (87) from control board.
87 ti13572a
5. Unscrew reed switch (87) from control panel (37).
37
87
ti13573a
4.Replace control panel (37) and tighten bottom two screws (61). Torque to
37
61
ti15795a
5.Replace display cover (33k) and torque four screws (33b) to
NOTE: Make sure noise shield tabs are routed to the inside of the control box when assembling.
Digital Display
Digital Display
Removal
1.Turn off unit. Wait 5 minutes before servicing.
2.Remove four screws (33b) and remove display cover (33k).
33k
ti15786a
33b
3.Unplug display board connector from motor control board (24).
24
ti13569a
A
Installation
1.Plug display board connector (A) into motor control board (24).
A
2.Replace display cover (33k) and torque four screws (33b) to
33k
ti15786a
33b
NOTE: Make sure noise shield tabs are routed to the inside of the control box when assembling.
Inline Valve
Changing the Needle
Removal
Inline Valve
5.Tap rear of inline valve with a plastic mallet and punch to push needle assembly (404b) out through front of housing (401).
NOTE: Needle (404b), housing/seat (404c), and
404b
Installation
ti15809a
401
1.Perform Pressure Relief Procedure, see page 4.
2.Squeeze trigger while unscrewing housing/seat (404c) and
404a
404c
ti15810a
3. Remove trigger stop (420) with hex wrench.
420
ti15862a
4. Remove locknut (414) and bracket (413).
ti15811a
1.Guide threaded end of needle assembly (404b) into front of housing (401).
ti15804a
404b 401
2.Install bracket (413) and locknut (414) loosely on threaded end of needle (404b). Squeeze trigger to pull needle assembly into housing (401).
3.Squeeze trigger while installing
404a
404c
413 414
ti15626a
t15805Xa
404b
4. Adjust needle before using inline valve.
Inline Valve
Needle Adjustment
1.Engage inline valve (135) with safety latch. Hold inline valve with nozzle straight up.
2.Hold your finger against trigger (410) with light pres- sure. Use a 5/16
3.Turn locknut (414) 3/4 turn
4.Connect fluid hose. Prime the system. Trigger inline valve (135) and release it. The fluid flow should stop immediately. Engage safety latch and try to trigger inline valve. No fluid should flow. If the inline valve fails either test, relieve pressure, disconnect hose and readjust needle.
5.Install trigger stop (420) when needle has been properly adjusted.
Box Slide Control
Use Brake Assembly Repair Kit 24F261
Removal
1. Remove set screw from brake knob (518b).
518a
518b
ti15863a
2. Unthread brake knob (518b) from assembly.
518b
ti15862a
Replacing the Battery
Removal
1.Unscrew battery cap (425a) from housing (411). Remove battery and discard.
411
426
425a
ti15812a
Installation
1.Install battery (426) in housing (411) and screw in battery cap (425a).
NOTE: Make sure
ti15865a
Installation
1.Thread brake knob (518b) onto assembly
2.Apply label (518a).
3.Torque set screw to
Parts
Parts
Parts
Pump Module Parts
Pump Module Parts List
Parts
??? 257600 Repair Kit is available with control board only. * 257601 Repair Kit is available with control board only.
Parts
Inline Valve Parts 24F538
??? Repair Kit 24F262 is a
Box Slide Parts 24F463
502
503
505b
505a
514
512
513
507
509
511
501
Parts
514
512
513
519
520
508
506
510
518a
518b
ti15834a
Wiring Diagrams
Wiring Diagrams
Thermal
Switch
Digital Display
Motor
Potentiometer
Pressure
Transducer
Black
Green/Ground
Black
Green/Ground
White
Prime/Fill Tool
Reed switch
20A/15A Switch
ON/OFF
Switch
Black
ti14889a
Wiring Diagrams
Thermal
Switch
Digital Display
Motor
Sensor
Leads
Black Blue
Blue
Green/Ground
Brown
Blue
Brown
Green/Ground
ti15686a
Wiring Diagrams
Thermal
Switch
Motor
Digital Display
Potentiometer
Pressure
Transducer
Black
Motor
Leads
Motor
Sensor
Leads
Blue
Green/Ground
Control
Board
Black
Blue
Brown
Brown
Prime/Fill Tool
Reed switch
Blue
ti15685a
Technical Data (Unit)
Technical Data (Unit)
Technical Data (Pump)
Notes
Notes
Notes
Notes
Graco Standard Warranty
Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco???s written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED
TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco???s sole obligation and buyer???s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS
The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la r??daction du pr??sente document sera en Anglais, ainsi que tous documents, avis et proc??dures judiciaires ex??cut??s, donn??s ou intent??s, ?? la suite de ou en rapport, directement ou indirectement, avec les proc??dures concern??es.
Graco Information
For the latest information about Graco products, visit www.graco.com.
TO PLACE AN ORDER, contact your Graco distributor or call
All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice.
Original instructions. This manual contains English. MM 3A0246
Graco Headquarters: Minneapolis
International Offices: Belgium, China, Japan, Korea
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN
Copyright 2010, Graco Inc. is registered to ISO 9001
www.graco.com
Revised 02/2011