Kit Instructions

Model 24T885

Important Safety Instructions

Read instruction manual 3A1319 for complete instructions and warnings. This Kit is not a substitute for reading and understanding all instruction manuals and warning labels supplied with the equipment.

1

6

11

10

14

4 5

300 psi LPG Gas Gauge Installation for ThermoLazer

1.Close manual gas shutoff valve on propane tank, then disconnect gas supply hose (99) from propane tank.

99

2.Unscrew gas supply hose (99) from bulkhead fitting (102).

99

102

ti22105a

3.Apply pipe sealant to tee fitting (11) and screw into bulkhead fitting (102). Screw in until gas tight. Install tee as shown.

11

ti22101a

4.Apply pipe sealant to bushing (6) and screw into tee fitting (11). Screw in until gas tight. Position gauge

(1) as shown.

1

6

11

ti22100a

NOTICE

Tighten by turning bushing (6) and holding tee fitting (11). Do NOT turn gauge (1). Damage to the gauge will occur.

5.Apply pipe sealant to filter fitting (10) and screw into tee fitting (11). Screw in until gas tight.

11 10

ti22098a

6.Apply pipe sealant to hose (99) and screw into filter fitting (10). Screw in until gas tight.

10 99

ti22099a

7. Connect gas supply hose (99) to propane tank.

ti14411b

8. Open manual gas shutoff valve on propane.

ti14127a

9.Check gas line for gas leaks (see ThermoLazer Operation Manual).

Pressure Tap Installation for ThermoLazer

Pressure Tap Installation for ThermoLazer

1. Close manual gas shutoff valve on propane tank.

9.Install new gas line (3) by screwing into gas safety valve adapter fitting (164) and screwing into adapter fitting (4). Screw in until gas tight.

ti14128a

2. Disconnect gas supply hose (99) from propane tank.

ti22114a7

5

99

4

3

10. Connect gas supply hose (99) to propane tank.

99

ti22097a

3. Remove and discard existing gas line (3) by unscrewing from elbow fitting (161) and unscrewing from gas safety valve adapter fitting (164).

ti14411b

4.Remove and discard existing elbow fitting (161) by unscrewing from manual gas shutoff valve (9).

11. Open manual gas shutoff valve on propane.

9

ti22104a

164

ti14127a

161 3

5.Apply pipe sealant to elbow fitting (8) and screw into manual gas shutoff valve (9). Screw in until gas tight. Position fitting as shown.

6.Apply pipe sealant to adapter fitting (7) and screw into tee fitting (11). Screw in until gas tight.

7.Apply pipe sealant to adapter fitting (4) and screw into tee fitting (11). Screw in until gas tight.

8.Apply pipe sealant to adapter fitting (7) and screw into elbow fitting (8). Screw in until gas tight. Posi- tion fittings as shown.

12.Check gas lines for gas leaks (see ThermoLazer Operation Manual).

All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice.

For patent information, see www.graco.com/patents.

Original instructions. This manual contains English. MM 332653