Instructions/Parts List
TRITON?? 3D350HP
Diaphragm Pump
311689G
ENG
Used to pump waterborne and
Part No. 253707, Series D
3:1 Ratio
Part No. 253708, Series D
3:1 Ratio
0.6 MPa, 6 bar (88 psi) Maximum Air Input Pressure
1.8 MPa, 18 bar (260 psi) Maximum Fluid Working Pressure
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.
TI1962A
II 2 G
Contents
2
The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbol refers to
Warning
EQUIPMENT MISUSE HAZARD
Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury.
???This equipment is for professional use only.
???Read all instruction manuals, tags, and labels before operating the equipment.
???Use the equipment only for its intended purpose. If you are not sure, call your Graco distributor.
???Do not alter or modify this equipment. Use only genuine Graco parts and accessories.
???Check equipment daily. Repair or replace worn or damaged parts immediately.
???Do not exceed the maximum working pressure of the lowest rated system component. Refer to the Technical Data on page 25 for the maximum working pressure of this equipment.
???Use fluids and solvents which are compatible with the equipment wetted parts. Refer to the Techni- cal Data section of all equipment manuals. Read the fluid and solvent manufacturer's warnings.
???Do not use hoses to pull equipment.
???Route hoses away from traffic areas, sharp edges, moving parts, and hot surfaces. Do not expose Graco hoses to temperatures above 82??C (180??F) or below
???Wear hearing protection when operating this equipment.
???Comply with all applicable local, state, and national fire, electrical, and safety regulations.
PRESSURIZED EQUIPMENT HAZARD
Spray from the gun, hose leaks, or ruptured components can splash fluid in the eyes or on the skin and cause serious injury.
???Do not point the gun at anyone or at any parts of the body.
???Do not stop or deflect leaks with your hand, body, glove, or rag.
???Follow the Pressure Relief Procedure on page 10 whenever you are instructed to relieve pressure; stop spraying; clean, check, or repair the equipment; and install or clean the spray nozzle.
???Tighten all fluid connections before operating the equipment.
???Check the hoses, tubes, and couplings daily. Replace worn, damaged, or loose parts immediately. Permanently coupled hoses cannot be repaired; replace the entire hose.
FIRE AND EXPLOSION HAZARD
Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury.
???Ground the equipment and the object being sprayed. Refer to Grounding on page 9.
???If there is any static sparking or you feel an electric shock while using this equipment, stop the equipment immediately. Do not use the equipment until you identify and correct the problem.
???Provide fresh air ventilation to avoid the buildup of flammable fumes from solvents or the fluid being sprayed.
???Keep the work area free of debris, including solvent, rags, and gasoline.
???Eliminate all ignition sources such as pilot lights, cigarettes, and static arcs from plastic drop cloths. Do not plug in or unplug power cords or turn lights on or off in the spray area.
3
Warning
TOXIC FLUID HAZARD
Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, inhaled, or swallowed.
???Know the specific hazards of the fluid you are using.
???Store hazardous fluid in an approved container. Dispose of hazardous fluid according to all local, state and national guidelines.
???Always wear protective eyewear, gloves, clothing and respirator as recommended by the fluid and solvent manufacturer.
???If a diaphragm fails, fluid is exhausted along with the air. When pumping hazardous fluids, place the pump in an appropriate container to catch the fluid if a diaphragm ruptures.
MOVING PARTS HAZARD
Moving parts, such as the diaphragm shaft, can pinch or amputate your fingers.
???Before servicing the equipment, follow the Pressure Relief Procedure on page 10 to prevent the equipment from starting unexpectedly.
PERSONAL PROTECTIVE EQUIPMENT
You must wear appropriate protective equipment when operating, servicing, or when in the operating area of the equipment to help protect you from serious injury, including eye injury, inhalation of toxic fumes, burns, and hearing loss. This equipment includes but is not limited to:
???Protective eyewear
???Clothing and respirator as recommended by the fluid and solvent manufacturer
???Gloves
???Hearing protection
4
Installation
Installation
General Information
???FIG. 3 on page 8 is only a guide for installing system components and accessories. It is not an actual sys- tem design. Contact your Graco distributor for assis- tance in designing a system to suit your particular needs.
???Always use Genuine Graco Parts and Accessories, available from your Graco distributor. If you supply your own accessories, be sure they are adequately sized and
???Reference numbers and letters in parentheses refer to the reference numbers in the figures and the parts list on page 23.
Tighten Threaded Connections
1.Before each use, check all hoses for wear or dam- age and replace as necessary.
2.Check to be sure all threaded connections are tight and
3.Check and
5
Installation
Mounting the Pump
For ease of operation and service, mount the pump so the air inlet, fluid inlet, and fluid outlet ports are easily accessible. The inlet port must point down and the outlet port must point up.
Use 5/8 in. lag screws or bolts for mounting.
To ensure proper operation, mount the pump in a horizontal position.
Wall Mount Installation
1.Wall Mount Kit 245875 is available. See FIG. 1.
2.Be sure the wall can support the weight of the pump, bracket, hoses and accessories, as well as the stress caused during operation.
3.Using the wall bracket (B) as a template, drill 5/8 in. mounting holes in the wall. See page 27 for a wall mounting diagram. Mount the bracket
4.Attach the bracket (B) to the pump (A) with the screws (C) and washers (D) provided in the kit.
5.Attach the bracket to the wall. Use screws (E) that are long enough to keep the pump from vibrating during operation. Be sure the pump is level.
C
D
A
B
E
TI2079B
FIG. 1: Wall Mount Kit
6
Installation
1.Install the air line accessories as shown in FIG. 3. Mount these accessories on the wall or on a bracket. Be sure the air line supplying the accesso- ries is grounded.
a.Install an air regulator (C) and gauge to control the fluid pressure. The fluid outlet pressure will be three times the setting of the air regulator.
b.A
c.The air line filter (D) removes harmful dirt and moisture from the compressed air supply.
d.A second
2.Install a grounded, flexible air hose (A) between the accessories and the pump air inlet. See Technical Data on page 25 to determine the air inlet size of your pump. Use a minimum 13 mm (1/2 in.) ID air hose.
3.Screw an air line quick disconnect coupler (N) onto the end of the air hose (A), and screw the mating fit- ting into the pump air inlet snugly. Do not connect the coupler to the fitting until you are ready to oper- ate the pump.
Fluid Suction Line
???Use conductive hoses (E). See FIG. 3.
???See Technical Data on page 25 to determine the fluid inlet size of your pump.
???For maximum suction lift (wet and dry) information, see Technical Data on page 25.
1.Use conductive fluid hoses (J). See FIG. 3. See Technical Data on page 25 to determine the fluid outlet size of your pump.
2.Install a fluid drain valve (G) near the fluid outlet. The fluid drain valve is required to relieve pressure in the hose and gun. The drain valve reduces the risk of serious injury, including splashing in the eyes or on the skin, or injury from toxic fluids.
3.Install a shutoff valve (H) in the fluid outlet line.
7
Installation
TD
C BA
N J
F
TI1961B
Key:
FIG. 3. Typical Installation
8
Grounding
Before operating the pump, ground the system as explained below. Read the warnings on page 3.
Ground all of this equipment:
???Pump: use a ground wire and clamp. See FIG. 4. Loosen the grounding screw (X). Insert one end of a 1.5 mm2 (12 ga) minimum ground wire (Y) into the pump???s grounding clamp (8) and tighten the screw
(X) securely. Connect the other end of the wire to a true earth ground. For a ground wire and clamp, order Part No. 238909.
???Air and fluid hoses: Use only electrically conductive hoses.
???Air compressor: Follow manufacturer???s recommen- dations.
???All solvent pails used when flushing: Follow your local code. Use only metal pails, which are conduc- tive, placed on a grounded surface. Do not place the pail on a nonconductive surface, such as paper or cardboard, which interrupts the grounding continu- ity.
Installation
X
Y
TI2085A
9
Operation
Operation
Pressure Relief Procedure
Read the warnings on page 3, and follow the Pres- sure Relief procedure below whenever you:
???are instructed to relieve pressure
???stop spraying
???check or service any of the equipment
???install or clean the fluid nozzle.
1.Shut off the air to the pump.
2.Open the dispensing valve, if used.
3.Open the fluid drain valve to relieve all fluid pres- sure, having a container ready to catch the drain- age.
7.With the pump air regulator (C) closed, open the
8.If the fluid hose has a dispensing device, hold it open while continuing with the following step.
9.Slowly open the air regulator (C) until the pump starts to cycle. Allow the pump to cycle slowly until all air is pushed out of the lines and the pump is primed.
If you are flushing, run the pump long enough to thor- oughly clean the pump and hoses. Close the air regula- tor. Remove the suction tube (E) from solvent and place it in the fluid to be pumped.
Operating the pump beyond the maximum air input pressure will decrease diaphragm life.
Do not operate the pump dry for long periods of time to avoid reducing diaphragm life.
Flush the Pump Before First Use
The pump was tested in oil. If the oil could contaminate the fluid you are pumping, flush the pump thoroughly with a compatible solvent. Follow the steps under Start- ing and Adjusting the Pump.
Pump Shutdown
Short Term Shutdown
For a short term shutdown, relieve the pressure (see at left).
Starting and Adjusting the Pump
1.Be sure the pump is properly grounded. Refer to
Grounding on page 9.
2.Check all fittings to be sure they are tight. Be sure to use a compatible liquid thread sealant on all male threads.
3.
4.Place the suction tube (E) in the fluid to be pumped.
5.Place the end of the fluid hose (J), see FIG. 3, into an appropriate container.
6.Close the fluid drain valve (G). Open the fluid shutoff valve (H).
Long Term Shutdown
For a long term shutdown, such as several hours or overnight:
1.Flush the pump thoroughly.
2.Leave compatible solvent in the pump.
3.Relieve the pressure (see at left).
10
Maintenance
Maintenance
Lubrication
CAUTION
Lubrication of the pump is not required. Oil is exhausted through the muffler, which could contami- nate the fluid supply or other equipment. Excessive lubrication can also cause the pump to malfunction.
Flushing and Storage
Flush the pump with a compatible solvent often enough to prevent the fluid you are pumping from drying in the pump and damaging it. Follow the Pressure Relief Pro- cedure on page 10 before storing it for any length of time.
Tighten Threaded Connections
1.Before each use, check all hoses for wear or dam- age, and replace as necessary.
2.Check to be sure all threaded connections are tight and
3.Check and
NOTE: Before using pump, loosen fluid cover screws (31)
Preventive Maintenance
Schedule
Establish a preventive maintenance schedule, based on the service history of the pump. This is especially impor- tant for prevention of spills or leakage due to diaphragm failure.
11
Troubleshooting
Troubleshooting
12
Troubleshooting
Outlet Manifold Tube
Optional Fluid Outlet
Outlet Ball Check
Diaphragm
Air Piston
Carriage
Diaphragm Shaft
Inlet Manifold Tube
Inlet Ball Check
Air Valve
Air Valve Gasket
Air Valve Cup
Diaphragm Shaft
Fluid Outlet
Outlet Ball Check
Diaphragm
Inlet Ball Check
Fluid Inlet
Driver Carriage
Carriage
Air Inlet
FIG. 5. Cutaway Views of Pump and Air Valve
13
Repair
Repair
Prepare the Pump for Repair
1.Flush the pump if possible, page 11.
2.Relieve the pressure, page 10.
3.Disconnect the air and fluid hoses.
4.Remove the pump from its mounting and take it to the work bench.
General Repair Notes
??? A qualified technician should make all repairs.
??? Inspect and clean all parts thoroughly before reassembly.
???Use only genuine Graco replacement parts, available from your Graco distributor.
???Be careful not to damage sealing surfaces.
???Replace all
???Follow all lubrication, torque, and repair notes in the repair procedures.
???Do not use silicone or
Fault Indications
During operation, check for indications of worn or dam- aged parts, such as:
???major pressure fluctuations
???change in the pump???s operating sound
???irregular operation.
Always replace worn or damaged parts immediately to prevent additional damage.
Tools Required
???4, 5, 6, 8 and 10 mm allen wrenches
???13 mm open end wrench
???28 mm open end wrench, or adjustable wrench
???two flat blade screwdrivers
???#2 Phillips screwdriver
???internal snap ring pliers
???dowel rod (wood or plastic)
???
???diaphragm installation tool (part number 261695)
14
Replace the Diaphragms
Diaphragm Repair Kit 243152 is available. Parts included in the kit are marked, for example (14*). For the best results, replace both diaphragms and all
Diaphragm Repair Tool 261695 is available to assist with diaphragm installation.
Operating the pump beyond the maximum air input pressure will decrease diaphragm life.
Do not operate the pump dry for long periods of time to avoid reducing diaphragm life.
Disassembly
1.Prepare the pump for repair, page 14.
2.Remove the screws (31) from one fluid cover (1). Pull the cover assembly off, separating it from the fluid tubes (12). See FIG. 6.
3.Remove the fluid tubes (12) from the other cover assembly.
4.Remove the screws (31) and the remaining fluid cover (1).
5.Install diaphragm (14) using the diaphragm repair tool to force the shaft all the way to one side. Press the short, wide boss on the tool directly on the dia- phragm. The part number on the tool should face away from the pump. See FIG. 6.
6.Unscrew the opposite diaphragm (14) from the shaft by turning it counterclockwise by hand.
7.Push the shaft in the opposite direction by installing the diaphragm repair tool on the opposite side of the pump. Press the tall boss on the tool directly on the pump shaft. The part number on the tool should face toward the pump. See FIG. 6.
8.Unscrew the remaining diaphragm (14) from the shaft by turning it counterclockwise by hand.
Reassembly
1.While the diaphragm repair tool holds the shaft to one side, screw the new diaphragm (14*) into the shaft by hand. See FIG. 6.
Repair
2.Depress the first diaphragm (14*) using the dia- phragm repair tool and install the opposite dia- phragm (14*) by hand.
3.Remove the
4.Install the cover assembly that has the tube hous- ings (4) attached. The arrow must point toward the top of the pump and the air inlet (40) must be to the right of the cover (1). Torque the screws (31) to 20 N???m (15
5.Lubricate the
6.Install the cover assembly that has the fluid inlet (3) and outlet (2) housings attached. The arrow must point toward the top of the pump. Seat the cover securely on the fluid tubes (12). Torque the screws (31) oppositely and evenly to 20 N???m (15
15
Repair
14*
14*
4
40
13* 1
2 31
4
TI8632A
Diaphragm Repair Tool 261695
FIG. 6. Replace the Diaphragms
2
31 2
1
3
TI1959A
TI8633A
16
Repair the Air Valve
Air Valve Repair Kit 243153 is available. Parts included in the kit are marked, for example (33???). For the best results, use all parts in the kit.
Disassembly
1.Prepare the pump for repair, page 14.
2.Remove the screws (31) from one fluid cover (1). Pull the cover assembly off, separating it from the fluid tubes (12). See FIG. 7.
3.Remove the screws (31) and the other fluid cover
(1) assembly, keeping the fluid tubes (12) attached.
4.Remove the air inlet fitting (40).
5.Remove the screws (68) and the top (67) and bot- tom (66) covers.
6.Remove the diaphragms (14), page 15.
7.Remove the four screws (38) and washers (37), air valve cover (36), and gasket (35).
8.Pry the air valve seat (33) out of the housing (5), using two screwdrivers inserted in the recesses on the seat. Remove the
9.Remove the cup (47) from the center housing.
10.Remove the two clips (46) from the shaft (17).
11.Remove the screws (30), cylinder outer cover (11), and cylinder (7). Do not lose the
12.Pull out the piston (16) and shaft assembly.
13.Remove the screws (29) and inner cover (6).
14.Remove the clips (50) from the air valve plugs (51). Thread a screw (38) partially into each plug and pull the plugs out. Remove the
15.Push the driver carriage (48) out of its bore. Remove the
16.Remove the clips (21) and push the bearings (18) out of the center housing (5), inner cover (6), and outer cover (11). Remove the
17.Remove the carriage (45).
Repair
Reassembly
Lubricate all
1.Install the
(18).Install the bearings in the center housing (5), cylinder inner cover (6), and cylinder outer cover
(11).Secure with the clips (21).
2.Install the carriage (45) in the center housing (5), oriented as shown.
3.Install the
4.Install the
5.Check that the
6.Check that the
7.Check that the
8.Insert the air valve tube (24) through the cylinder inner cover (6). Install the cover on the center hous- ing (5). Seat the air valve tube securely in the center housing, oriented with the spring pin (27). Torque the screws (29) to 8 N???m (5.9
9.Lubricate the diaphragm shaft (17), then slide it into the center housing (5), guiding the air valve tube
(24)through the hole in the piston. Install the two clips (46) on the shaft.
10.Liberally grease the inside of the cylinder (7) and the piston
11.Install the
(11).Install the outer cover. Torque the screws (30) to 15 N???m (11
17
Repair
12.Install the cup (47???) in the center housing.
13.Install the
14.Install the gasket (35???), cover (36), and screws and washers (38, 37). Torque to 6 N???m (4.4
15.Reinstall the diaphragms (14), page 15.
67
4
38 36 71
37 35???
29 2
21 19???18 20???
3 30
16.Install the fluid covers (1). The arrows must point up. Torque the screws (31) to 20 N???m (15
17.Check that the felt strips (71) are in place on the inside of the top (67) and bottom (66) covers. Install the covers. The hole for the air inlet fitting must align with the port in the center housing (5). Tighten the screws (68).
18.Install the air inlet fitting (40).
1Lubricate.
2Torque to 8 N???m (5.9
3Torque to 15 N???m (11
4Torque to 6 N???m (4.4
31
12
40
32
16
26
17 1
46
1
FIG. 7. Repair the Air Valve
18
Replace the Ball Check Valves
Ball Check Valve Repair Kit 243154 is available. Parts included in the kit are marked, for example (56???). For the best results, use all parts in the kit.
Sealing Ring Repair Kit 243156 is available. Parts included in the kit are marked, for example (55???). For the best results, use all parts in the kit.
Disassembly
1.Prepare the pump for repair, page 14.
2.Remove the screws (38) and take the tube assem- blies off the pump. See FIG. 8.
3.Remove the springs (65), ball guides (57), and balls (56) from the outlet (top) check valves.
If the ball is stuck in the seat, pry it loose with a screwdriver.
Some parts will be reused, so be careful not to drop or lose parts.
4.Insert a dowel through the outlet seats (53) and push the inlet (bottom) valve parts (65, 57, 56, 53, 58) out of the pump. Remove the flat seal (59).
5.Insert a dowel through the inlet ports and push the outlet valve seats (53) and sleeves (54) out of the pump. Remove the flat seals (55, 59).
Reassembly
CAUTION
The outlet ball check valves must be installed exactly as shown in FIG. 8:
???beveled side of seat (53) must face the ball (56)
???beveled end of sleeve (54) must face the seat (53)
???open end of ball guide (57) must face the ball (56)
???turned down end of spring (65) must face the ball guide (57)
1.Install the outlet check valves into the fluid covers (1): a flat seal (59???), seat (53???), seal (59???), sleeve (54), ball (56???), ball guide (57???), spring (65???), and seal (55???).
Repair
2.Install the outlet tube assembly. Torque the screws (38) to 10 N???m (7.4
CAUTION
The inlet ball check valves must be installed exactly as shown in FIG. 8:
???turned down end of spring (65) must face the ball guide (57)
???open end of ball guide (57) must face the ball (56)
???beveled side of seat (53) must face the ball (56)
???wide end of seal (58) must face the seat (53)
3.Install the inlet check valves into the fluid covers (1): a spring (65???), ball guide (57???), ball (56???), seat (53???), flat seal (59???), and seal (58).
4.Install the inlet tube assembly. Torque the screws (38) to 10 N???m (7.4
19
Repair
65???
1
57???
FIG. 8. Replace the Ball Check Valves
20
Replace the Cylinder and Piston
Seals
Cylinder Seal Repair Kit 243155 is available. Parts included in the kit are marked, for example (22???). For the best results, use all parts in the kit.
Disassembly
1.Prepare the pump for repair, page 14.
2.Remove the screws (38) and tube assemblies. See FIG. 9.
3.Disassemble the ball check valves, page 19. The flat seals (55, 59) are included with this repair kit.
4.Remove the air inlet fitting (40).
5.Remove the screws (68) and the top (67) and bot- tom (66) covers.
6.Remove the screws (31) and fluid covers (1).
7.Remove the diaphragms (14), page 15.
8.Remove the four screws (38) and washers (37), the air valve cover (36), and the gasket (35).
9.Pry the air valve seat (33) out of the center housing (5), using two screwdrivers inserted in the recesses on the seat.
10.Remove the
11.Remove the cup (47) from the housing.
To further disassemble and repair the air valve, see page 17.
12.Remove the two clips (46) from the shaft (17).
13.Remove the screws (30), cylinder outer cover (11), cylinder (7), and cylinder
14.Pull the piston (16) and shaft out of the center hous- ing (5). Remove the piston
Repair
15.Remove the screws (29) and cylinder inner cover
(6). Remove the air valve tube (24) and
16.Remove the
Reassembly
Lubricate all
1.Install the
2.Install the
3.Install the
4.Insert the air valve tube (24) through the inner cover
(6). Install the cover on the housing (5). Seat the tube securely in the housing, oriented with the spring pin (27). Torque the screws (29) to 8 N???m (5.9
5.If the piston (16) was removed from the piston shaft (15), reassemble a washer (61), the piston, and another washer on the shaft. Screw the diaphragm shaft (17) onto the piston shaft.
6.Lubricate the shaft (17) and slide it into the housing (5), guiding the tube (24) through the hole in the pis- ton. Install the two clips (46) on the shaft.
7.Liberally grease the inside of the cylinder (7) and the piston
8.Install the
9.Install the cup (47) in the center housing (5).
10.Install the
11.Install the gasket (35), cover (36), and screws and washers (38, 37). Torque to 6 N???m (4.4
21
Repair
12.Install the diaphragms (14), page 15.
13.Install the fluid covers (1). The arrows must point up. Torque the screws (31) to 20 N???m (15
14.Check that the felt strips (71) are in place on the inside of the top (67) and bottom (66) covers. Install the covers. The hole for the air inlet fitting must align with the port in the center housing (5). Tighten the screws (68).
15.Install the air inlet fitting (40).
16.Install the flat seals (55???, 59???) and the other ball check parts, see page 19.
17.Install the tube assemblies. Torque the screws (38) to 10 N???m (7.4
1Lubricate.
2Torque to 8 N???m (5.9
3Torque to 15 N???m (11
4Torque to 6 N???m (4.4
5Torque to 20 N???m (15
6Torque to 10 N???m (7.4
4 38
37
36
35
57
71
43
33
80
34
67
44
47
5
50
51
53
48
14
40
32???1
17
1
61
65
57 56 55??????
54
59??????
1
31 5
65
57
56 ??????55 53
54
??????59
1
27
51
1 28 50
2 29
61
???26 1
15
16
68
46
1 23???
56
53 59??????
58
FIG. 9. Replace the Cylinder and Piston Seals
TI2074B
22
Parts
Parts
Part No. 253707 includes items
Part No. 253708 includes items
60
13*
38
2 65???
57??? 56???
???65 ???57 ???56 53???
??????55
50
51 ???52 ???49
5
45
42???
24
27 28 ???52
51
46
17
29 50
20???
62
63
64
32???
40
39
???26 61
23???
61 16
12
55??????
54
59??????
1
31
65???
57???
56???
53???
59??????
58 3
60
38
7
22???
11
66
71
13*
68
68
TI1957B
23
Parts
Part No. 253707 includes items
Part No. 253708 includes items
* Included in Diaphragm Repair Kit 243152.1
??? Included in Air Valve Repair Kit 243153.
??? Included in Ball Check Valve Repair Kit 243154.
??? Included in Cylinder Seal Repair Kit 243155.
??? Included in Sealing Ring Repair Kit 243156.
NOTE: ??? Replacement Warning labels, signs, tags, and cards are available at no cost.
24
Technical Data
Technical Data
25
Performance Charts
Performance Charts
FLUID FLOW lpm (gpm); tested in No. 10 weight oil
Recommended Performance for Continuous Duty
CYCLES PER MINUTE
FLUID OUTLET PRESSURE MPa, bar (psi)
FLUID FLOW lpm (gpm); tested in No. 10 weight oil
26
Dimensions
Fluid Outlet; see page 25 for sizes.
360 mm (14.2 in.)
Fluid Inlet; see page 25 for sizes.
146 mm
(5.7 in.)
318 mm
(12.5 in.)
Wall Mount Hole Pattern
For Accessory Wall Mount Kit 245875
260 mm (10.25 in.)
100 mm (4 in.)
Dimensions
213 mm (8.4 in.)
M8 Mounting
Holes
Air Inlet; see page 25 for sizes.
160 mm
(6.3 in.)
TI1964A
TI1963A
Four 9 mm (0.35 in.) diameter holes, to mount the bracket to the wall
Torque Sequence
???Always follow torque sequence when instructed to torque fasteners.
???Torque bolts twice to 20 N???m (15
27
Graco Standard Warranty
Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco???s written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED
TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco???s sole obligation and buyer???s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS
The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la r??daction du pr??sente document sera en Anglais, ainsi que tous documents, avis et proc??dures judiciaires ex??cut??s, donn??s ou intent??s, ?? la suite de ou en rapport, directement ou indirectement, avec les proc??dures concern??es.
Graco Information
For the latest information about Graco products, visit www.graco.com.
TO PLACE AN ORDER, contact your Graco distributor, or call this number to identify the distributor closest to you:
All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice.
This manual contains English. MM 311689
Graco Headquarters: Minneapolis
International Offices: Belgium, China, Japan, Korea
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN
Copyright 2006, Graco Inc. is registered to ISO 9001
www.graco.com
Revised 09/2009