Used to pump waterborne and
115 psi (0.8 MPa, 8 bar) Maximum Fluid Working Pressure 115 psi (0.8 MPa, 8 bar) Maximum Air Input Pressure
Part No. 233500 Aluminum Pump, Series D, npt threads
Part No. 233501 Stainless Steel Pump, Series C, npt threads
Part No. 233776 Aluminum Pump, Series C, BSPP threads
Part No. 233777 Stainless Steel, Series C, BSPP threads
U.S. and Foreign Patents Pending
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.
Table of Contents
Safety Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Service
Remove the Fluid and Side Covers . . . . . . . . . . . 14
Ball Check Repair . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Diaphragm Repair . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Air Valve Repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Shaft Repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Graco Standard Warranty . . . . . . . . . . . . . . . . . . . . . . 26
Graco Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Symbols
Warning Symbol
WARNING
This symbol alerts you to the possibility of serious injury or death if you do not follow the instructions.
Caution Symbol
CAUTION
This symbol alerts you to the possibility of damage to or destruction of equipment if you do not follow the instructions.
2 309303
WARNING
EQUIPMENT MISUSE HAZARD
Equipment misuse can cause the equipment to rupture, malfunction, or start unexpectedly and result INSTRUCTIONS in a serious injury.
DThis equipment is for professional use only.
DRead all instruction manuals, tags, and labels before operating the equipment.
DUse the equipment only for its intended purpose. If you are not sure, call your Graco distributor.
DDo not alter or modify this equipment. Use only genuine Graco parts and accessories.
DCheck equipment daily. Repair or replace worn or damaged parts immediately.
DDo not exceed the maximum working pressure of the lowest rated component in your system. This equipment has a 115 psi (0.8 MPa, 8 bar) maximum working pressure at 115 psi (0.8 MPa, 8 bar) maximum incoming air pressure.
DUse fluids and solvents which are compatible with the equipment wetted parts. Refer to the Tech- nical Data section of all equipment manuals. Read the fluid and solvent manufacturer???s warnings.
DAluminum pumps only: Never use
DDo not use hoses to pull equipment.
DRoute hoses away from traffic areas, sharp edges, moving parts, and hot surfaces. Do not expose Graco hoses to temperatures above 180_F (82_C) or below
DWear hearing protection when operating this equipment.
DComply with all applicable local, state, and national fire, electrical, and safety regulations.
309303 3
WARNING
FIRE AND EXPLOSION HAZARD
Improper grounding, poor air ventilation, open flames, or sparks can cause a hazardous condition and result in fire or explosion and serious injury.
DGround the equipment. Refer to Grounding on page 7.
DIf there is any static sparking or you feel an electric shock while using this equipment, stop pump- ing immediately. Do not use the equipment until you identify and correct the problem.
DProvide fresh air ventilation to avoid the buildup of flammable fumes from solvents or the fluid being pumped.
DKeep the work area free of debris, including solvent, rags, and gasoline.
DElectrically disconnect all equipment in the work area.
DExtinguish all open flames or pilot lights in the work area.
DDo not smoke in the work area.
DDo not turn on or off any light switch in the work area while operating or if fumes are present.
DDo not operate a gasoline engine in the work area.
4 309303
WARNING
PRESSURIZED FLUID HAZARD
Spray from the gun, hose leaks, or ruptured components can splash fluid in the eyes or on the skin and cause serious injury.
DDo not stop or deflect fluid leaks with your hand, glove, or rag.
DFollow the Pressure Relief Procedure on page 11 before cleaning, checking, or servicing the equipment.
DTighten all fluid connections before each use.
DCheck the hoses, tubes, and couplings daily. Replace parts immediately if worn, damaged, or loose. Permanently coupled hoses cannot be repaired.
TOXIC FLUID HAZARD
Hazardous fluids or toxic fumes can cause a serious injury or death if splashed in the eyes or on the skin, swallowed, or inhaled.
DKnow the specific hazards of the fluid you are using. Read the fluid manufacturer???s warnings.
DStore hazardous fluid in an approved container. Dispose of the hazardous fluid according to all local, state, and national guidelines.
DWear appropriate protective clothing, gloves, eyewear, and respirator.
DIf the diaphragm fails, the fluid is exhausted along with the air.
309303 5
Installation
General Information
DFig. 2 shows a wall mounted HVLP spray applica- tion. It is only a guide for selecting and installing system components. Contact your Graco distributor for assistance in planning a system to suit your needs.
DAlways use Genuine Graco Parts and Accessories, available from your Graco distributor. If you supply your own accessories, be sure they are adequately sized and pressure rated for your system.
DUse a compatible, liquid thread sealant on all male threads. Tighten all connections firmly to avoid air or fluid leaks.
NOTE: On all npt threads, tighten to
DReference numbers and letters in parentheses refer to the callouts in the figures and the parts lists on pages
DIn a spray system, ventilate the spray booth.
Tightening Threaded Fasteners Before
First Use
NOTE: Before using pump, loosen fluid cover screws (38)
(10
See the Service section for torque specifications.
DAfter unpacking the pump, and before using it for the first time, check and retorque all external fas- teners.
DAfter the first day of operation, retorque the fasten- ers.
DAs a general guideline, retorque fasteners every two months.
WARNING
FIRE AND EXPLOSION HAZARD
To prevent hazardous concentrations of toxic and/or flammable vapors, spray only in a properly ventilated spray booth. Never operate the spray gun unless ventilation fans are operating.
Check and follow all of the national, state, and local codes regarding air exhaust velocity requirements.
WARNING
TOXIC FLUID HAZARD
Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, inhaled, or swallowed.
1.Read TOXIC FLUID HAZARD on page 5.
2.Use fluids and solvents which are compatible with the equipment wetted parts. Refer to the Technical Data section of all equipment manu- als. Read the fluid and solvent manufacturer???s warnings.
Mounting the Pump
DMount the pump in a
DBe sure the mounting can support the weight of the pump, hoses, and accessories, as well as the stress caused during operation.
DThe pump may be mounted vertically or horizontal- ly. Be sure the pump is level in all directions.
DWall, pail, stand, or portable cart mounting kits are available from Graco. For other mountings, be sure the pump is adequately secured. The pump has two mounting holes for 0.35 in. (9 mm) screws. See the Dimension drawing on page 25.
6 309303
Installation
Grounding
WARNING
FIRE AND EXPLOSION HAZARD
This pump must be grounded. Before operating the pump, ground the system as explained below. Also read the sec- tion FIRE AND EXPLOSION HAZARD on page 4.
To reduce the risk of static sparking, ground the pump and all other equipment used or located in the pumping area. Check your local electrical code for detailed grounding instructions for your area and type of equip- ment.
Ground all of this equipment:
DPump: Attach a ground wire (Y) to the pump???s grounding screw (35) and secure with the screw, as shown in Fig. 1. Connect the clamp end of the ground wire to a true earth ground. Order Part No. 238909 Ground Wire and Clamp.
35Y
ti1030b
Fig. 1
DAir and fluid hoses: Use only electrically conductive hoses.
DAir compressor: Follow the manufacturer???s recom- mendations.
DSolvent pails used when flushing: Follow your local code. Use only metal pails, which are conductive. Do not place the pail on a
DFluid supply container: Follow your local code.
309303 7
Installation
Air Line
WARNING
A
1.Install the air line accessories as shown in Fig. 2. Mount these accessories on the wall or on a bracket. Be sure the air line supplying the acces- sories is electrically conductive.
a.The fluid pressure can be controlled in two ways, either by controlling the air into the pump with the air regulator (F) or the fluid out of the pump with the fluid regulator (H).
b.Locate a
c.Install an air line filter (D) to remove harmful contaminants such as dirt, moisture, and oil from the compressed air supply.
2.The air valve does not require lubrication.
3.Install an electrically conductive, flexible air hose
(C) between the accessories and the pump air inlet
(T). Use a minimum 1/4??? (6.3 mm) ID air hose. Screw an air line quick disconnect coupler (V) onto the end of the air hose and screw the mating fitting into the pump air inlet snugly. Do not connect the coupler to the fitting yet.
8 309303
Installation
Wall Mount HVLP Spray Installation Shown
KEY
ATRITON 308 Pump
B
CAir supply line
DAir line filter
EAir line shutoff valve
FPump air regulator
GGun air regulator (used in spray system only)
HFluid pressure regulator (used in spray
system only)
JDrain/circulation valve
KDrain tube
LSuction tube
MPump fluid inlet
NPump fluid outlet
PFluid hose (shown connected to gun in spray system)
RGun air hose (used in spray system only)
SSpray gun (used in spray system only)
TPump air inlet
UAgitator (used in spray system only)
VAir line quick disconnect
Y Ground wire
J
N
K
G T
F
B
S
HY R
E D J
Y
K
H
ti1020a
A
M
L
ti1007a
Fig. 2
309303 9
Installation
Fluid Suction Line
DScrew the suction line (L) into the pump inlet (M) snugly. Use a compatible liquid thread sealant on connections to prevent air from getting into the fluid line.
DDo not pressure feed this pump.
DSee the Technical Data on page 24 for maximum suction lift.
DUse an agitator (U) to prevent fluid from settling out. Part No. 245081 Agitator Kit (accessory) is available.
Fluid Outlet Line
WARNING
A fluid drain valve (J) is required in your system to relieve pressure in the hose if it is plugged. See Fig. 2. The drain valve reduces the risk of serious injury, including splashing in the eyes or on the skin, or contamination from hazardous fluids when relieving pressure. Install the valve close to the pump fluid outlet. To use the valve as a circulation valve, connect a tube (K) between the valve and pail.
CAUTION
Some systems may require installation of a pressure relief valve at the pump outlet to prevent overpres- surization and rupture of the pump or hose.
Thermal expansion of fluid in the outlet line can cause overpressurization. This can occur when using long fluid lines exposed to sunlight or ambient heat, or when pumping from a cool to a warm area (for example, from an underground tank).
Overpressurization can also occur if the pump is being used to feed fluid to a piston pump, and the intake valve of the piston pump does not close, causing fluid to back up in the outlet line.
DUse electrically conductive fluid hoses (P). Screw the fluid fitting into the pump outlet (N) snugly.
DInstall a fluid regulator (H) at the pump fluid outlet to control fluid pressure, if desired. See Air Line, step 1a, for another method of controlling pressure.
DInstall a fluid drain valve (J) near the fluid outlet. See the WARNING at left.
Flush the Pump Before First Use
The pump was tested in lightweight oil. If the oil could contaminate the fluid you are pumping, flush the pump thoroughly with a compatible solvent. Follow the steps under Starting and Adjusting the Pump on page 11.
10 309303
Operation
Pressure Relief Procedure
WARNING
The system remains pressurized until pressure is manually relieved. To reduce the risk of serious injury from pressurized fluid, accidental spray from the gun, or splashing of any fluid, follow this proce- dure whenever you
DStop spraying
DAre instructed to relieve pressure
DCheck or service any system equipment
DInstall, clean, or change spray nozzles
1.Shut off the
2.In a spray system, hold the gun (S) firmly against a grounded metal pail and trigger the gun to relieve the fluid pressure.
3.Place the drain tube (K) in a waste pail. Open the drain/circulation valve (J) to relieve any fluid pres- sure trapped in the system.
Starting and Adjusting the Pump
2.If lifting the pump, follow the Pres-
sure Relief Procedure above.
Explosion Hazard on page 4.
4.Check all fittings to be sure they are tight. Use a compatible liquid thread sealant on all male threads. Tighten the fluid inlet and outlet fittings snugly. Do not overtighten the fittings.
NOTE: Before using he pump,
5.Place the suction tube (L, if used) in the fluid to be pumped.
6.Place the fluid hose (P) in a container.
7.Close the drain/circulation valve (J).
8.Close the pump air regulator (F). Open all bleed- type master air valves (B, E).
9.If the fluid hose has a dispensing device, hold it open while continuing with the following step. Slowly open the air regulator (F) until the pump starts to cycle. Allow the pump to cycle slowly until all air is pushed out of the lines and the pump is primed.
If you are flushing, run the pump long enough to thoroughly clean the pump and hoses. Close the air regulator. Remove the suction tube from the solvent and place it in the fluid to be pumped.
Pump Shutdown
WARNING
To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the
Pressure Relief Procedure at left.
At the end of the work shift, flush the pump and relieve pressure.
309303 11
Maintenance
Tightening Threaded Connections
Before each use, check all hoses for wear or damage. Replace as necessary. Check that all threaded con- nections are tight and
NOTE: Periodically,
Cleaning
Clean the outside of the equipment daily, using a soft cloth and compatible solvent.
Clean the suction tube (L) and inlet strainer daily, using a compatible solvent.
Clean the air filter (D) in your main air line at least once a week.
Storage
Before storing the pump, always flush it and relieve pressure.
Preventive Maintenance Schedule
Establish a preventive maintenance schedule, based on the pump???s service history. This is especially impor- tant for prevention of spills or leakage due to dia- phragm failure.
Troubleshooting
WARNING
To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the
Pressure Relief Procedure on page 11.
1.Relieve the pressure before checking or servicing the equipment.
2.Check all possible problems and causes before disassembling the pump.
12 309303
Troubleshooting
309303 13
Service
Remove the Fluid and Side Covers
Tools Required
DTorque wrench
D2.5 mm allen wrench
D6 mm allen wrench
DAdjustable wrench
Disassembly
WARNING
To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the
Pressure Relief Procedure on page 11.
1.Relieve the pressure.
2.Disconnect the hoses and ground wire.
3. Remove the pump from its mounting.
CAUTION
Be careful that the ball checks do not fall out when you remove the fluid covers (32).
4.Remove the six screws (38) and top cover (32) from the center housing (1). Remove the ball check seals (24). Remove the bottom cover and seals.
NOTE: Always replace the ball check seals (24) when- ever the fluid covers (32) are removed. These seals are included in the four repair kits.
NOTE: Perform step 5 only if you are servicing the air valve or the diaphragm shaft.
5.Remove the two screws (39) and take off the side cover (31) and felt dampener (29).
14 309303
Service
Remove the Fluid and Side Covers (continued)
Reassembly
1.Clean all parts and inspect for wear or damage. Replace parts as needed.
2.If necessary, reinstall the felt dampener (29) and side cover (31). Torque the screws (39) to 28
3.Install new ball check seals (24).
4.Place the fluid covers (32) on the housing (1). Align the mounting holes (H) in the fluid covers with the holes in the housing. Install the screws (38) loosely, then torque oppositely and evenly to 10
5.Reinstall the pump on its mounting.
6.Reconnect the ground wire and hoses.
H 1
32
Fig. 3
309303 15
Service
Ball Check Repair
Tools Required
D
Disassembly
NOTE: Ball Check Repair Kit 245067 is available. Parts included in the kit are marked with a double dagger, for example (21}). Use all the parts in the kit for the best results.
1.Remove the fluid covers. See page 14.
2.Remove the inlet and outlet ball checks. Note that the orientation of the inlet check parts is different from the outlet check parts. See Fig. 4.
NOTE: If the inlet seats (26) are difficult to remove, drive them out from the opposite side using a brass rod and hammer.
3.Clean all parts and inspect for wear or damage. Replace parts as needed.
Reassembly
1.Reinstall the inlet and outlet ball checks on one side of the pump. The inlet and outlet checks are assembled differently. Install the parts exactly as shown in Fig. 4.
2.Install one cover (32) loosely, to prevent the ball checks from falling out. See page 14.
3.Turn the pump over and install the ball checks on the opposite side, exactly as shown.
4.Reinstall the fluid covers. See page 14.
1
ti1032a
Fig. 4
16 309303
Service
Diaphragm Repair
Tools Required
DM8 bolt
DM8 hexnut
DAdjustable wrench, or vise
NOTE: Diaphragm Repair Kit 245065 is available. Parts included in the kit are marked with an asterisk, for example (6*). Always replace both diaphragms for the best results.
1. Remove the fluid covers. See page 14.
WARNING
Wear gloves when removing the diaphragms to reduce the risk of cuts.
2.Unscrew one diaphragm (6) from the shaft (5) by hand. See Fig. 5.
2
1 38
6*
2
24*
24*
*6
32
1 38
Fig. 5
3.Thread an M8 hexnut (A) onto an M8 bolt. Screw the bolt into the shaft (5) until it bottoms out. Thread the nut down to the shaft to lock it.
4.Hold the nut with a wrench or vise to keep the shaft from turning. Unscrew the other diaphragm
(6) by hand.
NOTE: If you cannot remove the second diaphragm, refer to Shaft Repair Disassembly on page 20.
Reassembly
1.Screw the new diaphragms (6*) into the shaft (5) handtight.
2.Replace the ball check seals (24*) with the new seals in the kit.
3.Reinstall the fluid covers. See page 14.
110
2Align
3Use M8 bolt and nut to keep shaft from turning.
A 3
ti1033a
309303 17
Service
Air Valve Repair
Tools Required
D3 mm allen wrench
DNeedlenose pliers
DRetaining ring removal tool
D
Disassembly
NOTE: Air Valve Repair Kit 245066 is available. Parts included in the kit are marked with a dagger, for exam- ple (8{). Use all the parts in the kit for the best results.
1.Remove the side cover (31) and felt dampener (29).
2.Remove the four screws (36), air valve cover (17), and gasket (16). See Fig. 7.
3.See Fig. 6. Note the orientation of the air valve plate (13) relative to the fluid outlet arrow, with ???POM??? marking up. Pull the plate out of the center housing (1). Remove the three
4.Remove the air valve cup (12) from the center housing (1).
5.Remove the retaining rings (11) and plug (9) from both sides, and slide the carriage (7) from the center housing (1). Remove the
6.Clean all parts and inspect for wear or damage. Replace parts as needed.
Orient ???POM??? marking on air
1valve plate as shown in relation to fluid outlet arrow.
1
???POM??? marking
fluid outlet arrow 1
13{
ti15226a
Fig. 6
18 309303
Service
Air Valve Repair (continued)
Reassembly
1.Lubricate the
2.Lubricate each
3.Install the air valve cup (12{) in the notch of the carriage (7) so the open side faces out.
4.Install two
5.Lubricate the large
6.Install the gasket (16{). Note the orientation.
7.Reinstall the air valve cover (17) and screws (36). Torque the screws to 28
8.Replace the ball check seals (24{) with the new seals in the kit.
9.Reinstall the felt dampener (29) and side cover (31). See page 14.
11 9
309303 19
Service
Shaft Repair
Tools Required
DNeedlenose pliers
D
DRetaining ring removal tool
DVise with soft jaws
Disassembly
NOTE: Shaft Repair Kit 24A155 is available. Parts included in the kit are marked with a star, for example (5l). Use all the parts in the kit for the best results.
NOTE: Shaft and Bearing Repair Kit is available. Parts included in the kit are marked with a symbol, for exam- ple (44l). Use all the parts in the kit for the best results.
1.Remove the fluid covers. See page 14. Remove the side cover (31) and felt dampener (29).
2.Disassemble the air valve. See page 18.
3.Remove the diaphragms (6). See page 17.
4.Remove the retaining rings (4l) from the shaft (5). See Fig. 8.
5.Slide the shaft (5) out of the center housing (1). Remove the valve carriage (3) from the housing.
6.Remove the retaining rings (47) and bearings (44). Remove the
CAUTION
Do not grip the shaft with tools that can scratch or damage the shaft, such as wrenches or pliers.
7.If you could not remove one diaphragm from the shaft, place the shaft in a vise with soft jaws. Unscrew the remaining diaphragm (6) from the shaft (5) by hand.
8.Clean all parts and inspect for wear or damage. Replace parts as needed.
Reassembly
1.Screw one diaphragm (6) into the shaft (5l) handtight.
2.Lubricate the
3.Place the valve carriage (3) in the center housing
(1). Grease the shaft (5l) and slide it through the center housing and valve carriage.
4.Install the retaining rings (4l) on the shaft (5l).
5.Screw the second diaphragm (6) into the shaft (5l) handtight.
6.Reassemble the air valve and carriage (see page 18), using the new
7.Replace the ball check seals (24l) with the new seals in the kit.
8.Reinstall the fluid covers. See page 14.
20 309303
Service
Shaft Repair (continued)
1 38
3
32
110
2Lubricate.
3Align.
428
5Align. See Fig. 6.
1 38
Fig. 8
31
39 4
ti1035E
309303 21
Parts
Part No. 233500 Aluminum Pump, Series D, npt threads
Part No. 233501 Stainless Steel Pump, Series C, npt threads (Shown) Part No. 233776 Aluminum Pump, Series C, BSPP threads
Part No. 233777 Stainless Steel Pump, Series C, BSPP threads
38
32
*6
33 30 40Y
37 20
18
28
7
{l8 {l10
9
11
}22
}27
}21 }23
*{}l24
19
45gl
gl46 gl47 44gl
Detail of Grounding Screw
26}
25}z
ti1030b
1
3
4l
12{
14{l
15{l
13{
16{l
17
36
43{l
29
31
6*
32
39
ti1036F
22 309303
Parts
309303 23
Sound Pressure Levels in dB(A)*
(measured at 1 m from unit)
Sound Power Levels in dB(A)*
(tested in accordance with ISO 3744)
Performance Chart
To find Fluid Outlet Pressure (psi/MPa/bar) at a specific fluid flow (lpm/gpm) and operating air pressure (psi/MPa/bar):
1.Locate desired flow along bottom of chart.
2.Follow vertical line up to intersection with selected fluid outlet pressure curve (black). Follow left to scale to read fluid outlet pressure.
To find Pump Air Consumption (l/min or scfm) at a specific fluid flow (lpm/gpm) and air pressure (psi/MPa/bar):
1.Locate desired flow along bottom of chart.
2.Read vertical line up to intersection with selected air consumption curve (dashes). Follow left to scale to read air consumption.
A115 psi (0.8 MPa, 8 bar) air pressure
B90 psi (0.6 MPa, 6 bar) air pressure
C60 psi (0.4 MPa, 4 bar) air pressure
D30 psi (0.2 MPa, 2 bar) air pressure
Test Fluid: No. 10 Weight Oil
Fluid Outlet Pressure
Air Consumption
24 309303
Dimensions
BOTTOM VIEW
4.53 in. (115 mm)
1/4 npt or 1/4 BSPP Air Inlet
4.1 in.
(104 mm)
SIDE VIEW
Aluminum
4.88 in.
(124 mm)
8.2 in.
(208 mm)
ti1037a
3/8 npt or 3/8 BSPP Fluid Outlet
Two 0.35 in. (9 mm) diameter holes, for mounting pump
3/4 npt or M26 x 1.5 Fluid Inlet
SIDE VIEW
SST
9.1 in.
(231.5 mm)
TI3265A
309303 25
Graco Standard Warranty
Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco???s written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or sub- stitution of
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT
NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco???s sole obligation and buyer???s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
Graco makes no warranty, and disclaims all implied warranties of merchantability and fitness for a particular purpose in connection with accessories, equipment, materials or components sold but not manufactured by Graco. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS
The parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnais- sent avoir convenu que la r??daction du pr??sente document sera en Anglais, ainsi que tous documents, avis et proc??dures judiciaires ex??cut??s, donn??s ou intent??s ?? la suite de ou en rapport, directement ou indirectement, avec les procedures concern??es.
Graco Information
For the latest information about Graco products, visit www.graco.com.
TO PLACE AN ORDER, contact your Graco distributor, or call one of these numbers to identify the distributor closest to you:
All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice.
Original instructions. This manual contains English. MM 309303
Graco Headquarters: Minneapolis
International Offices: Belgium, China, Japan, Korea
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN
Copyright 2001, Graco Inc. is registered to ISO 9001
www.graco.com
Revised 02/2011
26 309303