gGE Industrial Systems
INSTALLATION / USER MANUAL
Digital Energy??? LP 11U
Uninterruptible Power Supply
GE Digital Energy
LP 11U UPS Technology for the Digital World.
ver 3.0 - US
g
Digital Energy??? LP Series
OPERATING MANUAL Digital Energy LP
Manual version 3.0 Software version R2.11
INSTALLATION / USER MANUAL
Digital Energy??? LP 11U
Uninterruptible Power Supply
Preface
We thank you for selecting a General Electric Digital Energy??? LP Series Uninterruptible Power Supply (UPS) and recommend that you read these instructions carefully before installation and
Please keep this manual in a safe place for future reference and carefully read the important safety instructions in chapter 1 before installation of this device.
?? 2003 by GE Industrial Systems
All rights reserved.
The information contained in this publication is intended solely for the purposes indicated.
The present publication and any other documentation supplied with the UPS system is not to be reproduced, either in part or in its entirety, without the prior written consent of GE.
The illustrations and plans describing the equipment are intended as general reference only and are not necessarily complete in every detail. The content of this publication may be subject to modification without prior notice, no liability can be accepted for any error or omission.
g
Digital Energy??? LP Series
CONTENTS
1.1Save these instructions
1.2General
1.3Installation
1.4Storage
1.5Batteries
3.1Principles of Operation
3.2Normal Conditions
3.3Utility Failure
3.4Automatic Bypass Switch
3.5Manual Bypass Switch
4.5.1 Installation Procedures
4.5.1.1 Standard installation procedure: Vin
4.5.1.2 Installation procedure: Vin 120Vac (optional 5/6kVA), Vout 120/208/220/230/240Vac
4.5.2 Available input voltages: hardware modifications
4.5.2.1 Input voltage 208 or 240Vac
4.5.2.2 Input voltage 120Vac (optional, 5/6kVA only)
4.5.3 Available output voltages: hardware modifications
4.5.3.1 Output voltage 208Vac
4.5.3.2 Output volatge 120Vac
4.5.4 Input / output voltages: Software modification 4.5.5 Installation of DE LP battery extension pack(s)
4.5.6
4.5.6.1 Notes concerning installation of a parallel system 4.5.6.2 Notes concerning starting up the parallel system
4.5.6.3 Notes concerning use / maintenance of a parallel system
5.1 Description of Front and Rear Panel
5.2
5.3 Use
5.3.1 Information menu 5.3.2 Status and alarm menu 5.3.3 Service menu
5.3.4
5.4 Test Screens
5.4.1 Battery test, general 5.4.2 Quick battery test 5.4.3 Deep battery test
5.5 Other Features
5.5.1 Shutdown 5.5.2 Utility start
5.5.3 Sleep and
5.5.4 Overload protection in bypass mode 5.5.5
5 5.6 Auto restart
5.5.7 Superior battery management
g
Digital Energy??? LP Series
6.1RS232/Contact Interface
6.2Emergency Shutdown
6.3Relay Card (optional)
6.4SNMP Interface (optional)
7.1Extended Runtime
7.2
7.3
7.4PDM: Power Distribution Module
7.5Seismic Anchors
8.1General
8.2Cooling fan
8.3Batteries
8.4Safety
8.5Storage
8.6Recycling the UPS at the end of service life
g
Digital Energy??? LP Series
1- Important Safety Instructions
1.1Save these instructions
This manual contains important instructions that should be followed during installation and maintenance of the UPS and batteries. It also gives all necessary information about the correct use of the UPS.
Full understanding and compliance of the safety instructions and warnings contained in this manual are the ONLY CONDITION to avoid any dangerous situation during installation, operation and maintenance work, and to preserve the maximum reliability of the UPS system.
GE refuses any responsibility in case of
Before attempting to install and start up the UPS, carefully read this manual. Keep this manual next to the UPS for future references. All servicing must be done by qualified personnel. Do not attempt to service the UPS unless you have had proper training.
CAUTION: By opening or removing covers you run the risk of exposure to dangerous voltages!
While every care has been taken to ensure the completeness and accuracy of this manual, GE accepts no responsibility or liability for any loss or damage resulting from the use of the information contained in this document.
This document shall not be copied nor reproduced without the permission of GE.
Due to technical improvements, some of the information contained in this manual may be changed without notice.
1.2General
???CAUTION: RISK OF ELECTRIC SHOCK Do not remove the cover, there are no user serviceable parts inside. All maintenance and service work should be performed by qualified service personnel.
???The UPS contains batteries. The output terminals may be electrically live, even when the UPS is disconnected from the utility supply. Dangerous voltages may be present during battery operation. The batteries must be disconnected during maintenance or service work.
???The UPS contains potentially hazardous voltages.
1.3Installation
???Move the UPS in an upright position and in its original package to the final destination room.
???To lift the UPS, use a forklift or lifting belts with spreader bars.
???Check for sufficient floor and elevator loading capacity.
???Check carefully the integrity of the UPS equipment. In case you note some visible damage, do not connect any voltage to the UPS but contact the nearest Service Centre.
???This UPS is intended to be used in a controlled indoor environment and free of conductive contaminants and protected against animal intrusion.
???The UPS should only be powered from a single phase, three wire AC source equipped with an earth connection.
???In this manual "Earth" is represented with two different symbols:
= Field wiring equipment grounding terminal,
= Grounding terminals.
???Do not install the UPS in an excessively humid environment or near water.
???Avoid spilling liquids or dropping any foreign object into the UPS.
???The unit must be placed in a sufficiently ventilated area; the ambient temperature should not exceed
40?? C (104?? F). Optimal battery lifetime is obtained if the ambient temperature does not exceed 30?? C (86?? F).
g
Digital Energy??? LP Series
???It is important that the unit has adequate ventilation. Maintain air movement around and through the unit. Do not block the air vents.
???Avoid placing the unit in direct sunlight or near heat sources.
???Do not plug household appliances such as electric heaters, toasters or vacuum cleaners into the UPS. The UPS output is intended to be used only for electronic loads such as computers and telecommunications equipment.
???Use insulated copper input and output wiring, rated 90??C (194?? F) wire size based on the ampacities given in Tables
1.4Storage
???Store the UPS with its batteries fully charged in a dry location, storage temperature must be within
???If the unit is stored for an extended period of time, the batteries must be recharged periodically. Connect the unit to the mains and switch it on:
-if the storage temperature is within
-if the storage temperature is within
1.5Batteries
???NOTE: Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batteries.
???When replacing the batteries, use only the same type and size battery.
???CAUTION: A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed when working on batteries:
-Remove watches, rings or other metal objects.
-Use tools with insulated handles.
-Wear rubber gloves and boots.
-Do not lay tools or metal parts on top of batteries.
-Disconnect charging source prior to connecting or disconnect battery terminals.
-Determine if the battery is inadvertently grounded. If inadvertently grounded, remove source of ground. Contact with any part of a grounded battery can result in electrical shock. The likelihood of such shock will be reduced if such grounds are removed during installation and maintenance.
???Avoid charging in a sealed container.
???CAUTION: Never dispose of batteries in a fire: they may explode.
???CAUTION: Do not open or mutilate batteries: their contents may be extremely toxic. If exposed to electrolyte, wash immediately with plenty of water.
???Proper disposal or recycling of the batteries is required. Refer to your local codes for disposal requirements.
g
Digital Energy??? LP Series
2 - Introduction
2.1Description
More than ever before, today's advanced electronic equipment, with complex integrated circuits and other sensitive electronics, needs a stable and continuous AC power supply to operate correctly. While the power coming from the wall outlet is often unreliable, a GE Digital Energy???
A compact, truly
The UPS offers complete galvanic isolation of input and output, also when operating in bypass mode. As a result, input and output voltages do not necessarily have to be equal, making the UPS suitable for almost every situation.
All units are standard equipped with a backfeed protection relay.
Figure 1: The GE Digital Energy??? LP 11U UPS
2.2Warranty
GE Digital Energy, operating through its authorized agents, warrants that the standard products will be free of defects in materials and workmanship for a period of 24 months (12 months for the battery) after the date of invoice, or such other period as may be specified.
NOTE: This warranty does not cover failures of the product which result from incorrect installation, misuse, alterations by persons other than authorized agents, or abnormal operating conditions.
g
Digital Energy??? LP Series
3 - Functional Explanation
3.1The Principles of Operation
The UPS stores electric energy in batteries. This allows the UPS to supply output power even when the incoming utility power is cut off completely.
Energy is stored as Direct Current (DC), while input and output energy must be Alternating Current (AC). Therefore the UPS contains an input converter (AC to DC) and an output converter (DC to AC). (fig.2)
3.2Normal Conditions
Under normal conditions, energy from the utility is channeled through the input converter, which supplies the output converter and the battery charger. The batteries are kept in a fully charged state, and the output converter synthesizes a completely new AC output sine wave to supply the load (electrical equipment).
MICROPROCESSOR CONTROL
Figure 2. Block diagram of the LP 11U UPS, utility present
3.3Utility Failure
In the event of a utility power failure (i.e. absent or outside tolerance) the system uses the energy reserve stored in the battery to continue to produce AC power, ensuring unbroken output (fig. 3). No interruption or alteration will ever be noticed in the output power.
In the event of an extended utility failure, the output converter will stop when the battery has been discharged. At this point, the UPS is no longer able to power the connected equipment.
When the utility is
MICROPROCESSOR CONTROL
Figure 3. Block diagram of the LP 11U UPS, utility failure
g
Digital Energy??? LP Series
3.4Automatic Bypass Switch
If the output converter is unable to deliver the demanded output power because of overload or overtemperature, the automatic bypass switch will automatically transfer the load to the utility. When the situation is corrected the UPS will switch back to normal operation, i.e. the load is tranferred back to the output converter. Though the automatic bypass switch is shown as a simple mechanical switch in figures
In case of a severe overload or
MICROPROCESSOR CONTROL
Figure 4 . Bypass operation: Automatic bypass
If a power failure occurs during bypass operation, load power may be lost. If the UPS functions under overload conditions it may not be able to protect the load.
3.5Manual Bypass Switch (Service switch)
The system can be bypassed manually using the manual bypass switch located at the rear panel. It is a two- position switch: the normal position is '1': as in figures
CAUTION: REFER SERVICE TO QUALIFIED PERSONNEL ONLY.
THE RFI FILTERS AND OUTPUT TRANSFORMER ARE ALWAYS ACTIVE.
Figure 5 . Bypass operation: Manual bypass
g
Digital Energy??? LP Series
4 - Installation
4.1Transport
NOTE: Transport the UPS only in upright position. Check for sufficient floor and elevation loading capacity. Move the UPS in its original package to the final destination room. Do not stack other package on top.
4.2Unpacking
Cut the two wrapping bands, and remove the shipping box. Loosen the four bolts with which the UPS is fixed to the pallet. Remove the UPS from the pallet.
BE CAREFUL! Pay attention to the HEAVY WEIGHT of the UPS when downloading the UPS from the pallet! Never try to lift the unit by yourself!
The UPS is equipped with castors, which allow easy displacement of the unit. Please take appropriate measures to avoid damage on vulnerable floors.
4.3Package Contents
The shipping box contains a
4.4Location
Please refer to section 1.3 of ???IMPORTANT SAFETY INSTRUCTIONS???.
4.5 Installation
IMPORTANT:
Before making any connection and switching on the LP UPS, please check the following conditions:
???The voltage and frequency of your utility supply is 120/208/230/240 Vac and 50 or 60 Hz; from the factory the input and output of the UPS are set to 208 Vac / 60 Hz.
???Be sure that the UPS is wired for the present utility voltage. This is indicated on the packaging of the UPS, as well as at the I/O terminals.
???Overcurrent protection for the AC circuit is to be provided by others.
???CAUTION: To reduce risk of fire, connect only to a circuit input/output provided with
branch circuit overcurrent protection in accordance with the National Electrical Code, ANSI / NFPA 70, as indicated below:
Table 1. external input fuse value
g
Digital Energy??? LP Series
Table 4. Tightening torque force
g
Digital Energy??? LP Series
4.5.1Installation Procedures
4.5.1.1Standard installation procedure:
input voltage
If a battery extension pack is to be installed, please proceed with section 4.5.5.
If 2, 3 or 4 parallel operating units will be installed, please proceed with section 4.5.6. The numbers between (brackets) refer to figure 19 in section 5.1.
1
2
3
4
5
ON
OFF
BATTERY
DISCONNECTED
EMERGENCY
SHUTDOWN
67
see
Figure 6. LP
g
Digital Energy??? LP Series
4.5.1.2Installation procedure:
input voltage 120Vac (optional,
If a battery extension pack is to be installed, please proceed with section 4.5.5.
If 2, 3 or 4 parallel operating units will be installed, please proceed with section 4.5.6. The numbers between (brackets) refer to figure 19 and 20 in section 5.1.
2
4
5
BATTERY
DISCONNECTED
EMERGENCY
SHUTDOWN
67
see
Figure 7. LP
1.Mount the levellers: position A to fix the UPS to the floor, position B to lift the castors from the floor. Please refer to figure 6, step 1.
2.Loosen the screws and remove the conduit boxes (17, 2x) and the cover plate (11).
3.Make sure that all circuit breakers
4.Input/output connection:
Lead the input/output cables through the cable inlet. If the cables come from below (recommended for 8kVA and 10kVA models), you can rotate the cable inlet 90 degrees. Connect the input wires to the input terminals (11b). Connect the output wires to the output terminals (11a). Please refer to section 4.5.2.2 (input) and 4.5.3 (output) for detailed information.
5.
6.An emergency shutdown switch can be connected to connector J3 on the RS232/Contact Interface Card, between pins 3 and 4. See section 6.2 for more information.
7.For advanced communication possibilities, the RS232/contact interface port (12a) can be connected to a computer system. See section 6.1 for more information.
8.The middle ???option slot??? (13) allows easy installation of
9.The right ???option slot??? (14) allows easy installation of the
10.Connect the utility power to the UPS.
11.If hardware modifications were necessary in step 4 because the output voltage is different from the default (208Vac), software modifications should be performed as well. Proceed with 4.5.4.
12.For a quick start proceed with section 5.2
g
Digital Energy??? LP Series
4.5.2 Available input voltages: hardware modifications
The following input voltages are possible: 208, 240 Vac (see 4.5.2.1) and 120 Vac (see 4.5.2.2)
4.5.2.1Input voltage 208 or 240Vac.
1.Input voltage is 208 Vac. This is the factory setting. Proceed with step 3.
2.Input voltage is 240Vac. In this case the bypass tap on the output transformer must be changed. Please refer to fig. 8 and 8a. Proceed as follows:
2.1Remove the yellow wire B from faston 74 (connect) and place this wire on faston 72 (park).
2.2Remove the blue wire A from faston 61 (park) and place this wire on faston 74 (connect).
Bypass tap factory setting: 208 Volt
(park)
(park)
(connect)
Bypass tap changed to 240 Volt
(park)
(park)
(connect)
3.Connect the utility supply wires to terminals 6 (L1), 7 (L2) and 8 (equipment grounding conductor). See figure 9. Ground connection is essential!
If a neutral wire is part of the site wiring provided, we suggest to isolate this wire for future use or other applications.
Figure 9. LP
Output (grey) / input terminals
4.For the output voltage proceed with 4.5.3.
g
Digital Energy??? LP Series
4.5.2.2Input voltage 120Vac (optional, 5/6kVA only).
1.Connect the utility supply wires to terminals L, N and GND (equipment grounding conductor). See figure 10. Ground connection is essential!
Figure 10. LP
2.For the output voltage proceed with 4.5.3.
4.5.3 Available output voltages: hardware modifications
The
The following voltages are available: 120, 208, 220, 230, 240 Vac.
4.5.3.1Output voltage 208Vac
This is the
1.Connect the output wires to the terminals 1 (L1) and 4 (L2).
2.Connect the ground wire to terminal 5. Ground connection is essential! See figure 11.
Figure 11. LP
208 Vac output connection
3.Return to either 4.5.1.1 step 5 or 4.5.1.2 step 5
g
Digital Energy??? LP Series
4.5.3.2Output voltage 120Vac
1.The factory setting of the output tap (208Vac) has to be changed to 240Vac. Please refer to fig. 12 and 12a. Proceed as follows:
1.1Remove the yellow wire L from faston 67 (connect) and place this wire on faston 65 (park).
1.2Remove the brown wire F from faston 66 (park) and place this wire on faston 67 (connect).
Figure 12. LP
Output tap change
Figure 12a. LP
Rear view
2.Connect the load wires between the terminals 1 (L1) and 2 (N) (120V), and between the terminals 3 (N) and 4 (L2) (120V). Connect the ground wire to terminal 5. Ground connection is essential! Do not remove the link between terminals 2 and 3. See figure 13.
Figure 13. LP
120 Vac
3.Return to either 4.5.1.1 step 5 or 4.5.1.2 step 5
g
Digital Energy??? LP Series
4.5.3.3Output voltage 220/230/240Vac
1.The factory setting of the output tap (208Vac) has to be changed to 240Vac. Follow the procedure as described in section 4.5.3.2 steps 1.1 and 1.2.
2.Connect the load wires between the terminals 1 (L1) and 4 (N). Connect the ground wire to terminal 5. Ground connection is essential! Do not remove the link between terminals 2 and 3. See figure 14.
Figure 14. LP
3.Return to either 4.5.1.1 step 5 or 4.5.1.2 step 5
4.5.3.4Output voltage 120Vac single phase
1.The factory setting of the output tap (208Vac) has to be changed to 240Vac. Follow the procedure as described in section 4.5.3.2 steps 1.1 and 1.2.
2.Remove the link between terminals 2 and 3.
3.Place this link between terminal 1 and 2.
4.Place the extra link (delivered with the unit) between terminals 3 and 4.
5.Connect the load wires between connectors 1 (or 2) and 3 (or 4).
For LP 8/10kVA: If the wire size does not allow to place two wires (i.e. load wire and link) in one terminal, proceed with step 8.
6.Connect the ground wire to terminal 5. Ground connection is essential!
7.Return to either 4.5.1.1 step 5 or 4.5.1.2 step 5.
Figure 15. LP
120 Vac single phase output connection
g
Digital Energy??? LP Series
For LP 8/10kVA:
8.Remove all links between the terminals.
9.Split both the load wires and spread one wire over terminal
10.Connect the ground wire to terminal 5. Ground connection is essential! See figure 15a.
11.Return to either 4.5.1.1 step 5 or 4.5.1.2 step 5
Figure 15a. Output cable splitting for 8/10kVA 120V
4.5.4 Input/output voltages: Software modification.
NOTE: following this procedure you realize that the values shown in the LCD match the actual input/output voltages.
1.Switch on the circuit breakers 'utility' (8) and 'bypass' (9) (see also section 5.2, step
2.Go to the
SETUP SCREENS
ENTER/RESET exit
3.Using the
INPUT VOLTAGE 208V
4.Here you can change the input voltage to 240 Volt. The value of the input voltage blinks. Scroll through its settings by using the
INPUT VOLTAGE
CHANGE TO 240V
5.Go to the
OUTPUT VOLTAGE 208V
6.Here you can change the output voltage to 240 Volt. The value of the input voltage blinks. Scroll through its settings by using the
INPUT VOLTAGE
CHANGE TO 240V
7.To return to the default screen scroll to the
8.You can now proceed with 5.1 or 5.2.
g
Digital Energy??? LP Series
4.5.5 Installation of GE Digital Energy???
The numbers between (brackets) refer to figures
Battery extension pack(s) are shipped with all materials necessary to connect them to the UPS. The pack(s) can be connected to the DC connector (15) at the rear panel of the UPS. Be sure to switch off the UPS before proceeding: be sure that the UPS can be switched off without causing damage to the load, and turn all circuit breakers
2
3
4
5
Figure 16. LP
Installation of battery pack
1.Open the DC fuse holders at the rear of the battery pack (16) and make sure that the fuses have been removed.
1a. Open the DC fuse holders at the rear of the UPS (16) and make sure that the fuses have been removed.
2.UPS rear panel: loosen the screws, and remove the cover plate (11) and conduit box (17).
CAUTION! The battery voltage is 240Vdc and is NOT isolated from the utility.
3.Break out the indicated part of the conduit box, fix the gland of the DC cable in this opening.
4.Connect the DC connector of the battery pack (15a) to the DC socket of the UPS (15). Be sure that the colours match. You will hear a click when the cable is properly installed.
5.
6.In case of 14Ah battery packs: using the DC connector of the battery pack (15) you can install a second, third, etc. pack. 7Ah battery packs cannot be connected in parallel.
NOTE: A maximum of two Digital Energy??? 14Ah battery cabinets can be connected without additional fusing. Every two additional Digital Energy??? 14Ah battery cabinets must be connected over a 60Amp fuse, rated for 300Vdc.
NOTE: Third party battery cabinets must be connected over a 60Amp fuse, rated for 300Vdc, using the Digital Energy??? external battery cable (order separately).
7.Insert the 2 (7Ah) or 4 (14Ah) DC fuses of the (each) battery pack, insert the DC fuses of the UPS and close the fuse holder(s) of battery pack and UPS (16).
8.In order to calculate the available
In case of a
9.Be sure that the UPS is switched off, and disassemble the RS232/Contact Interface Card (12) from the unit. If the card is disassembled during normal operation the UPS will shut down!
Remove the wire from connector J3 (pin 1 and 2). Install the wiring of a normally closed contact (e.g. an auxiliary contact of a circuit breaker) to pin 1 and 2.
Proceed with 4.5.1 or 5.2.
g
Digital Energy??? LP Series
4.5.6 LP 11U series: 2 / 3 / 4 parallel operating units ??? additional info
The RPA option (Redundant Parallel Architecture) allows you to create a redundant UPS system in which 2, 3 or 4
This section gives aditional information on:
-installation (4.5.6.1)
-
-use / maintenance (4.5.6.3)
4.5.6.1Notes concerning installation of a parallel system
1.All inputs of the UPSs must be supplied from the same phase. This is to enable bypass operation of the parallel system. All inputs must be individually protected by fuses in the installation. The values of these fuses should correspond to the values mentioned in section 4.5 table 1.
2.All outputs must be connected together, supplying the load. It is advised to install switches (S
3.The diameter of input and output cables must be according to the table in the installation drawings (see appendix). Cables with different diameters can cause tripping fuses in the UPS and/or the installation.
4.The length of all input cables from the input junction (Li, fig. 17) to the UPS inputs should be equal. The same applies to the cables from the outputs to the output junction (Lo, fig. 17). The minimum length of the input as well as the output cables is 3 meters / 10 feet.
INPUT JUNCTION
F
DISTRIBUTION
FUSE VALUES
ACCORDING TO
TABLE 1
S
SWITCH ALLOWS
ISOLATION OF A UNIT
FROM THE SYSTEM
Figure 17. Installation of parallel operating
g
Digital Energy??? LP Series
5.The right option slot (14) at the rear of the unit contains the the
-loosen the screws, remove the
-set the dipswitch to the appointed number (fig. 18)
-
Do NOT install the network cables between the
Figure 18. Appointing a unique number to each UPS in the system
6.In the UPS many parameters can be set. It is advised to keep the same setting for each parameter in each UPS in the parallel system. In any case the following parameters are critical and should have equal settings:
-autorestart (on/off, see 5.3.3)
-output voltage (120/208/220/230/240 Vac, see 5.3.4)
-output frequency (50/60 Hz, see 5.3.4)
It is absolutely required that these parameters are set to the same value. Off factory this is the case. If you???re not sure that the units have equal settings:
-be sure that the
-be sure that utility power is connected to the UPS
-start each unit individually (see 5.2), check / change the parameters, and switch the unit off again.
7.Interconnect the
4.5.6.2 Notes concerning starting up the parallel system
For starting up the system please refer to section 5.2.
After switching on all units the LP UPSs will show the following display:
AUTORESTART OFF
PRESS ENTER
After pressing the ???Enter/Reset??? button on one of the units the system will start up. All units will display the standard screen. The number in the lower right corner indicates the number of the UPS in the system.
If the parameters mentioned in 4.5.6.1 step 6 are not set to the same value the UPS will display the following screen after
AUTORESTART OFF
SETTING MISMATCH
In this case check and correct the setting of the parameters as mentioned in 4.5.6.1, step 6.
g
Digital Energy??? LP Series
4.5.6.3 Notes concerning use / maintenance of a parallel system
If
If
Manual bypass:
If you want to switch one of the UPSs to bypass operation using the manual bypass switch (switch is turned into position 2) then all UPSs in the parallel system have to be switched to bypass operation in order to prevent damage.
Maintenance:
To isolate a unit from the redundant system:
1.Switch off the UPS which has to be isolated,
2.Remove the installation fuse from the input of that UPS
3.Separate the output of the UPS from the output junction
To
4.Reinstall the installation input fuse,
5.Connect the output of the UPS to the output junction,
6.Switch on the UPS.
g
Digital Energy??? LP Series
5 - Operation
5.1Description of Front and Rear Panel
6 5 1 2 4 3
16 7 8 9
10
15 11
11b
17
18
14
13
12
1LCD screen
2x16 characters, shows UPS system data, status messages, settings.
The language is selectable: English, German, French, Italian, Spanish. Section 5.3.4 describes the selection procedure.
With the button keypads ???Down??? (2) and ???Up??? (4) you can scroll through the several screens, with keypad 'Enter/Reset' (3) a selection is confirmed. Keypad activity is accompanied by a short beep. If there is no keypad activity during 20 seconds the LCD screen will return to the default screen (except for the service screens, see section 5.3.3).
5LED 'operation' indicates normal operation.
6LED ???alarm???, indicates an alarm situation, accompanied by alarm message(s) on the display and a sounding buzzer.
See section 5.3.2 for more information.
7Switch ???UPS on/off???, turns on/off the complete UPS, including the automatic bypass!
8Circuit breaker ???Utility on/off???, protection fuse for utility input and battery charger.
9Circuit breaker ???Bypass on/off???, fuse to protect the system in case of severe overload or short circuit in the UPS load.
WARNING: In position 2, if the input line is energized, the output is also live regardless the position of the circuit breakers ???utility??? and ???bypass???.
11Cover plate, behind it: 11a Output terminals
11b Input terminals
12RS232/Contact Interface Card, with:
12a - RS232 Interface Port (see section 6.1)
-Emergency shutdown (see 4.5.1 and 6.2)
-Battery disconnected, pin
13Free option slot for
-Relay Card (see 6.3)
-SNMP Card (see 6.4)
14Option slot for RPA (Redundant Parallel Architecture) Card. Not available yet.
15DC socket / connector.
16Battery fuse holder
17Conduit box
18Cable inlet
Figure 19 : Front and rear panel
g
Digital Energy??? LP Series
Rear panel of the
11b Input terminals L, N and GND
17Conduit box
18Cable inlet
17
Figure 20. Rear panel of the
15a
19
Rear panel of (optional) battery extension pack:
15DC socket (14Ah only) 15a DC connector
16Battery fuse holder(s)
19 Gland to fasten cable in conduit box of UPS
Figure 21. Rear panel battery extension pack (optional)
g
Digital Energy??? LP Series
5.2
The numbers between (brackets) refer to figure 19 in section 5.1.
Note: the UPS can be started on battery power if the utility input voltage is not available or if circuit
breaker ???utility??? is in
1.Turn breaker 'utility' (8) and breaker 'bypass' (9), both on the rear panel, into position ???on??? (up).
2.Some UPS parameters (e.g. voltage, frequency, LCD language) are user selectable. If you want to change one or more settings, please refer to section 5.3.4
3.Turn switch 'UPS on/off' (rear panel, 7) into position ???on??? (up). The green LED 'operation' (front panel, 5) will illuminate.
After switching on the UPS performs a
SELFTEST
IN PROGRESS
After completion of the
LP
LOAD 37%
In case of a system failure the
4.Though the batteries (the internal energy reserve) were fully charged when the UPS left the factory, they might have lost some energy during transport and/or storage. It is recommended to allow the UPS to recharge the batteries for a few hours. This way you ensure that the UPS can provide sufficient runtime in case of a utility power failure.
5.If not yet switched on, the equipment connected to the UPS can be switched on now; operate as usual.
g
Digital Energy??? LP Series
5.3Use
Once the unit is in operation, there is no need to switch the unit on/off during use.
If the manual bypass switch (rear panel, 10) is in position '1', switching off by the on/off switch (rear panel, 7) results in a total absence of the output voltage (also the bypass voltage) of at least 5 secs.
If an emergency shutdown switch has been installed (see
The UPS is operated via the
The menus on the display can be divided into 5 groups:
1standard screen
2information menu (5.3.1)
3 status- and alarm menu (5.3.2)
4 service menu (5.3.3)
5
The standard menu shows UPS model and actual load.
LP
LOAD 37%
5.3.1 Information Menu
When the default screen is displayed the first information screen can be entered by depressing the 'up' key (front panel, 4). Using the 'up' and 'down' keys (front panel, 4 and 2) you can scroll through several information screens. After the last information screen the default screen will appear.
The screens display the following information:
INPUT LINE 208V 2.45kW 60Hz
AUTONOMY TIME
LEFT 5:27:00
OPERATING TIME 0YEAR 29DAYS
Utility voltage and utility frequency, and the power delivered by the utility.
Output voltages and output frequency, and the power delivered by the UPS (as % of the nominal UPS rating).
The temperature near the batteries, the battery voltage and the battery current (charging: + value, discharging: - value).
The remaining battery runtime (or autonomy) during a utility failure.
The total operating time of the UPS.
g
Digital Energy??? LP Series
5.3.2 Status and Alarm Menu
The UPS alerts the user with a standard alarm screen that the operating mode has changed and/or that an alarm situation occurs:
ON LINE
ALARM PRESS UP
The actual operating mode, the possible modes are mentioned below. The lower line
Possible operating modes:
The normal operating mode. For more information see section 3.2. Overload or failure situation. For more information see section 3.5. For a detailed description of this mode see section 3.3.
No power is delivered to the load. This can be the result of a command via the RS232 Port, or because no electric energy is available (utility failure, depleted batteries).
Service mode. For more information see section 3.6.
Depressing the 'up??? key from the standard alarm screen shows, in priority order, which alarms are active,. Scroll through the screens with the 'up' and 'down' keys. Alarm message texts can succeed each other. The following messages are possible:
LOADnotPROTECTED
CAP. C2 DEFECT
UPS OVERLOADED
REDUCE LOAD
UPS OVERLOADED LOAD 143%
The output capacitor C2 is defective. Contact your dealer.
The load exceeds the rated output power of the UPS, and the output voltage can no longer be guaranteed. This text alternates with the following screen:
showing the actual load as % of the nominal UPS rating. These messages are displayed if the load is > 100%.
If the load exceeds 150% the UPS will immediately switch to bypass, assuming that the conditions for a transfer to bypass are fulfilled. If an overload condition between
LOADnotPROTECTED
TEMP TOO HIGH
LOADnotPROTECTED
VOLTAGE TOO HIGH
BATTERY CHARGER
VOLTAGE TOO HIGH
BATTERY CHARGER
TEMP TOO HIGH
The temperature of the heatsinks or output transformer is too high. As a result the output voltage may be transferred to bypass.
The operating temperature can rise to intolerable levels as a result of:
???extreme environmental temperature
???lack of proper ventilation
???an overload situation
???fan failure
If the UPS operates in 'on line' mode, it will switch to bypass until the temperature is normal again. If however the UPS operates 'on battery', a shutdown will occur and output power is lost.
The internal DC voltage is too high, internal failure
The output voltage of the battery charger is too high, internal failure
The battery temperature is too high due to a battery failure or a too high ambient temperature
g
BATTERY CHARGER
NO FLOAT
CAPACITOR C1
CAPACITY LOW
LOADnotPROTECTED
INVERTER OFF
LOADnotPROTECTED
BATTERY DEPLETED
LOADnotPROTECTED
BATTERY LOW
UPS SHUTDOWN
LEFT 2 MINUTES
BYPASS ERROR
FUSE FAILURE
INPUT ERROR
FUSE FAILURE
INTERNAL BATTERY
FUSE FAILURE
EXTERNAL BATTERY
FUSE FAILURE
REPLACE BATTERY
INPUT out LIMITS 137V 60.0Hz
BYPASSoutLIMITS 197V 60.0Hz
Digital Energy??? LP Series
After 24 hours of charging time, the battery voltage did not reach the normal float voltage. This may be caused by faulty batteries, too many battery packs connected or a charger fault.
The main
Due to a failure the output converter's output is not available. As a result the load may have been transferred to bypass.
The remaining runtime is zero. As a result the load may have been transferred to bypass.
The remaining run time is less than the set time (standard 2 minutes). This text alternates with the following screen:
The output voltage can be lost after the indicated time due to discharged battery. Controlled shutdown of any computer equipment is absolutely necessary at this point. (Using the RS232 or SNMP communications interface, this procedure can be initiated automatically on unattended systems). If the UPS operates at 100% load, the shutdown procedure should be completed within 2 minutes after the 'battery low' alarm started. When the batteries are fully discharged, the UPS is no longer able to power the connected equipment.
The static bypass circuit breaker (rear panel, 9) is in 'off' (down position): no bypass voltage available. Utility voltage is available. If not manually operated, this may have been caused by an overload situation.
The utility circuit breaker (rear panel, 8) is in the 'off' (down position): no line voltage available, bypass voltage is available. If not manually operated, this may have been caused by an internal system failure.
The internal battery fuse is defective; this may have been caused by an internal system failure. This alarm also appears if no batteries are installed.
The
The batteries are (almost) chemically worn out. If the batteries are aged, they must be replaced as soon as possible to ensure full protection for your equipment (see section 8.3).
The utility voltage or utility frequency are outside UPS input tolerance (see chapter 10, specifications)
The utility voltage or utility frequency are outside bypass input tolerance but inside UPS (rectifier) input tolerance (see chapter 10, specifications). Bypass operation is inhibited: if for whatever reason the output converter is unable to deliver the required output, output power is lost.
g
INPUT AND OUTPUT
NOT SYNCHRONIZED
Digital Energy??? LP Series
The output converter frequency is not synchronized to the utility (input) frequency. In this situation the automatic bypass switch is not able to transfer the load from output converter to bypass and reverse: automatic bypass operation is inhibited: if for whatever reason the output converter is unable to deliver the required output, output power is lost. (see section 3.5).
Synchronization is only possible if the utility frequency remains within certain limits (see chapter 10).
BATTERY RUNTIME LEFT 0:09:41
OUTPUT OFF
NO INPUT POWER
PROG. SHUTDOWN WITHIN 0:09:17
PROG. SHUTDOWN LEFT 0:14:03
SHUTDOWN
ALARM PRESS UP
IMMEDIATE
SHUTDOWN
5.3.3 Service Menu
The remaining runtime. This figure is counted down during battery operation until either the utility returns or the batteries are depleted.
The output is switched off due to a faulty situation, indicated by the second line.
The output will be switched off by a remote command (RS232/SNMP). The second line indicates the time until shutdown.
The output is switched off by a remote command (RS232/SNMP). The second line indicates the time until
The output is switched off by the
The wire on connector J3 pin
When the default screen is displayed you can enter the first service screen by depressing the keys 'down' (2) and 'Enter/Reset' (3) simultaneously for approx. 1 second. Using the 'up' (4) and 'down' (2) keys you can scroll through several service screens.
SERVICE SCREENS ENTER exit
SERIAL NUMBER l051U01/0020A030
SOFTWARE VERSION R2.9; 640777
HEATSI.TEMP: 0
TRANSF.TEMP: 310
FLOAT CHARGE: 1
OUTPUT FAST : 0
The intro service screen. 'Enter/Reset' returns to the default screen.
The serial number of the UPS.
Release number of the installed software and production code of the UPS.
Service information about fan speed (min. 10, max. 30) and internal DC voltage.
Service information on internal temperature levels, values in mV over the temperature sensors.
First line: service information on charger. ???1??? = batteries have reached float voltage.
Second line: service information on output converter.
g
TSTAMP Q4 6028773 1
FREQ RANGE: 2%
NO LOAD : 1
QUICK BATTERY
TEST PRESS ENTER
CALIBRATE BAT
PRESS DOWN+ENTER
PF1 THYRISTOR 1
BATT.THYRISTOR 0
VSS THYRISTOR 0 PF1. CONVERTER 1
LAST TEST TIME 0:00:00
FORCE BYPASS press DOWN+ENTER
AUTOMATIC BYPASS
ENABLED
PLL LOCK SPEED
NORMAL
ECO DISABLED
ENTER/RESET CHNG
AUTO RESTART ON
ENTER/RESET CHNG
Digital Energy??? LP Series
Service information on internal timer.
Frequency tracking range: output converter frequency will follow the bypass frequency within these limits before returning to its own internal frequency. Standard setting: nominal ??2%. Can be changed into nominal ??4% or ??6%. See 5.3.4
Default setting = 1 (active). For disabling this feature see 5.3.4.
Start of the manual Quick Battery Test.
See for more information section 5.4.2 'Quick Battery Test'
Start of the manual Deep Battery Calibration Test.
See for more information sections 5.4.3 'Deep Battery Calibration Test'
Service information on internal UPS components
Service information on internal UPS components
Service information on internal UPS components
Batt.Charger: 0 = off, 1 = float charging; 2 = top charge, 3 = boost charging, 4 = maintenance charge
Duration of latest test performed, hh/mm/ss
The UPS transfers the load to bypass when the keys 'down' (2) and 'Enter/Reset' (3) on the front panel are depressed simultaneously for approx. 1 second. If the bypass supply is not within limits, the lower line will show the text 'UNAVAILABLE'.
Service
Service
Service
Service
Service
g
Digital Energy??? LP Series
5.3.4
To enter the
1.Be sure the UPS is switched off.
2.Press
Using
SETUP SCREENS ENTER/RESET exit
WARNING: OUTPUT
CHANGES ON LINE
LANGUAGE
ENGLISH
INPUT VOLTAGE 208V
OUTPUT VOLTAGE 208V
OUTPUT FREQUENCY 60.0Hz
FREQUENCY RANGE 2%
PLL LOCK SPEED
NORMAL
BATTERY CAPACITY 7Ah
FAN CURVE 0
YES
The intro
Pressing ???up??? displays the screens in the following order:
A short reminder that the new settings will be valid immediately after depressing the ???Enter/Reset??? key.
Changes the language of the screen messages: you can select English, German, French, Italian, Spanish.
The system input voltage: Range 120/208/240 Vac.
The system output voltage. Range: 120/208/220/230/240 Vac.
The system output frequency. Range: 50/60 Hz.
WARNING! Changing of the output frequency can cause severe damage of equipment connected to the UPS: Be sure that the new frequency is suitable for the connected equipment.
The frequency tracking range (in which the output converter frequency will follow the bypass frequency). Range: 2/4/6 %.
If the bypass frequency is beyond the setting, the output converter will return to the fixed crystal controlled frequency.
The frequency tracking speed range (in which the output converter frequency will follow the bypass frequency).
Range: NORMAL (1Hz/sec), HIGH (5Hz/sec).
Battery capacity. Range: 7 through 590 Ah, in 1 Ah steps.
WARNING! If you proceed, the information about the actual battery condition (as a result of a deep battery test) is lost. For more info see section 5.4.3 'Deep Battery Test'.
The fan speed. Range: 0 / 1. Proper setting optimizes the cooling capacity of the fans installed. DO NOT READJUST! Incorrect setting may lead to reduced lifetime of the power semiconductors.
Setting ???YES??? means that the function is activated: the UPS will switch off during a utility failure when the load is less than 2% of the maximum load. Range: YES/NO.
NOTE: if the UPS operates in parallel the
available. In this case do not activate this function: its setting should read "NO".
g
AUTOMATIC BYPASS
ENABLED
SERVICE WARNING
DISABLED
Digital Energy??? LP Series
Controls functioning of the automatic bypass switch. Range: ENABLED/DISABLED. If the UPS is used as a frequency converter you may change the setting to ???DISABLED???. Bypass operation will then be inhibited and all alarms related to ???bypass out of limits??? are suppressed.
The system can prompt for service to a user defined schedule.
Range: 8/12/16/20/24/28 months or DISABLED. To reset the timer: first select ???DISABLED??? and subsequently set a new alarm interval.
5.4Test Screens
These screens show the test procedure, either started from the service menu (front panel keys) or via the UPS monitoring software (RS232/SNMP). The upper line indicates the kind of test, the second line its status.
5.4.1 Battery Test, general
Automatic test: Every 500 operating hours the UPS conducts automatic battery tests to ensure that the batteries and the wiring are able to support power failures. The tests do not cause any interruption in the functioning of the unit.
Manual test: A manual battery test can be activated
-either through an interface kit, via the RS232 or SNMP Interface Port (please refer to the manual of your interface package), or
-via the front panel: see below
5.4.2Quick Battery Test
From the standard menu first enter the service menu (press the 'down' and 'Enter/Reset' keys simultaneously, then press the 'down' key until the following screen appears:
QUICK BATTERY
TEST PRESS ENTER
The ???Enter/Reset??? key confirms the selection, and the screen shows:
QUICK BATTERY
TEST START
The test status (indicated by the second line) can be: = testing
= battery has been tested with positive result = the batteries should be replaced
= battery capacity too low to start the test
If the batteries are dangerously close to being worn out, a low priority alarm 'replace battery' will be generated. The batteries must be replaced as soon as possible (see section 8.3).
NOTE: If the manual test is started immediately after installation or after a power failure, the UPS may generate a false 'replace battery' alarm as the batteries have been (partly) discharged during transport/storage or during the power failure.
g
Digital Energy??? LP Series
5.4.3 Deep Battery Test
The runtime as shown on the LCD screen is calculated, and the value is initially based on the capacity of new batteries. As batteries age, their capacity deteriorates, and as a result the initial battery capacity may be too unreliable for a proper runtime prediction. The UPS is able to keep track of the aging process, if a 'deep battery test' (battery calibration test) is executed regularly. During such a test the condition of the batteries is tested, and the result of the test is stored, and used by the UPS system for future runtime calculations.
We advise performing a deep battery test on a regular basis. For accuracy reasons the interval should depend on the number of discharges . With one discharge per month a 6 month interval is sufficient. If the discharge interval is shorter than once a week a monthly deep battery test is advised.
A deep battery test can be started only if the following conditions are met:
-The load should be more than 30% of nominal load
-The batteries should be fully charged (100% on screen)
-There are no alarms at the time the test is started.
Procedure:
From the standard menu first enter the service menu (press the 'down' and 'Enter/Reset' keys simultaneously for 2 seconds). Subsequently press the 'down' key until the following screen appears:
CALIBRATE BAT press DOWN+ENTER
Press the keys ???down??? (2) + 'Enter/Reset' (3) simultaneously, for at least 1 second.
The following screen appears:
CALIBRATE BAT
TEST ACTIVATED
The test is executed, this may take a few minutes with standard battery and full load. Partial load and/or batt. extension packs can lengthen the test period considerably. Do not change the load during the test, i.e. do not switch off or on connected equipment!
The deep battery test discharges the batteries to 'battery low' alarm level (see section 5.3.2 'battery low'). Please note that immediately after a deep battery test the expected run time is very short: allow the UPS to recharge its batteries.
After the test the second line informs about the result:
g
Digital Energy??? LP Series
5.5Other Features
5.5.1 Shutdown
'Remote shutdown': Using communication capabilities, the computer can direct the UPS to turn itself off following controlled shutdown of the system. Subsequently the UPS will remain off for at least a few seconds (see also 6.1). LED 'operation' will blink green. The unit will start up again as soon as the utility returns.
'Emergency shutdown': for more information see section 5.3.2, message 'IMMEDIATE SHUTDOWN'.
5.5.2 Utility start
The UPS is able to start, even if the batteries are not connected. Alarm messages 'BATTERY FUSE FAILURE' and 'BATTERY DEPLETED' will be shown. The run time is zero.
5.5.3 Sleep and
GE Digital Energy??? UPS monitoring software allows you to program a 'sleep period' of the UPS by sending two commands to the UPS:
-shut down after # minutes, and subsequently:
-shut down during # hours.
After the first command the following screen appears:
During the sleep period the output voltage is no longer available. LED 'operation' blinks green, and the LCD screen shows the time left until restart:
If a utility failure occurs during the sleep period and the battery voltage eventually drops below 200Vdc, the UPS will automatically switch off in order to save battery power. When the main returns the UPS will start up automatically. The programmed sleep time however is lost.
The sleep period can be cancelled by either turning the UPS ON/OFF switch (6) off for a few seconds or by sending the appropriate command via the RS232/SNMP port.
5.5.4 Overload protection in bypass mode
The UPS will protect itself in case of overload. Upon an overload which is caused by abnormal circumstances the UPS will switch to bypass operation, and subsequently the bypass input fuse on the front panel will trip. The capacity of the bypass fuse allows it to handle the inrush currents of the equipment connected to the UPS. The fuse will only trip after more than an hour at an input current of 40Amp (LP
In order to protect the UPS system the software will cut off the abnormal current:
Between
g
Digital Energy??? LP Series
5.5.5
The UPS is equipped with the
After enabling the
NOTE: If
5.5.6Auto restart
If this feature is enabled and the unit has shut down (e.g. due to overload) the UPS will start up automatically when the normal situation is restored. The
If the auto restart feature is disabled the unit will not automatically restart when the normal situation is restored but the display will show:
AUTO RESTART OFF
PRESS ENTER
After ???Enter??? the unit will restart. See also 5.3.3 ???service screens???.
5.5.7Superior Battery Management
-Load dependent
current: the higher the current, the lower the
-Equalize mode: When switched on for the first time the UPS will start
-Boost mode: If after a discharge the battery voltage is lower than 240Vdc, the UPS will charge the batteries with a boost charge voltage of 285Vdc. This enables fast recharging of the batteries. The programmed battery charging mode will change from boost charge into float charge after boost charging twice.
-Temperature compensated battery charging: This feature reduces the battery charge voltage with
increasing temperature
g
Digital Energy??? LP Series
6 - Interfacing Features
The UPS is equipped with 3 ???option slots??? (rear panel,
6.1RS232 / contact interface
The RS232/Contact interface
During a power failure the UPS software takes a number of actions: processes are stopped, open files are closed and unattended systems will be shut down in a controlled way. When the utility power returns, the systems will automatically start up and will be up and running as soon as possible.
For specific information on GE Digital Energy??? connectivity products please contact your dealer or internet: www.gedigitalenergy.com.
1Battery low
2Serial data out
3Serial data in / UPS shutdown
4Not used
5Common
6Bypass active
7Plug&Play / RTS
8Utility failure
contact interface: Max 48V / 30mA
Fig. 22: RS232 / contact interface
6.2Emergency shutdown
The emergency shutdown connector is located on the RS232/contact interface card (12). Be sure that the UPS is switched off, and remove the card from the unit*. Remove the wire from connector J3 (pin 3 and 4). Install the wiring of a normally closed contact to connector J3 (pin 3 and 4).
* If the card is removed during normal operation the UPS will shut down.
6.3Relay Card (optional)
The relay
6.4SNMP Interface (optional)
This SNMP
g
Digital Energy??? LP Series
7 - Optional Features
7.1Extended Runtime
Extended runtime versions are equipped with additional separate battery packs to increase the runtime of the unit. Additional batteries will increase the recharging time for the unit. All other operational information is the same.
If a battery pack is connected, the UPS must be informed about the new total battery capacity to allow a reliable recalculation of the available run time. Please refer to section 5.3.4
Connecting an external charger may cause damage to the UPS. As the batteries are not galvanically separated from the utility input, the external charger must be galvanically separated from the utility. Using an external charger will cause a false run time prediction during charging time, the correct run time will be shown 10 hours after reaching battery float charge. If you are in doubt, contact your dealer.
Battery pack A: 240V / 7 Ah
Battery pack B: 240V / 14 Ah
For more information please refer to the NOTES in section 4.5.5 step 6.
7.2
An option slot (rear panel, 13) allows easy installation of a relay or SNMP
7.3
Nowadays there are many
Connecting GE Digital Energy???
Redundancy: To achieve the highest possible level of power protection in a
By connecting units in parallel, using the N+x system, a redundant system can be created. In this case all the UPSs equally share the load in the system during normal operation. In this way every possible single point of failure will be eliminated. This means that if one of the UPSs in the parallel system fails, the other(s) can still supply the load guaranteeing full protection without any interruption.
Scalability: To add power if needed without investments beforehand.
Another reason for paralleling units is upgrading the power rating of the system. If e.g. a LP 5kVA is installed, the power rating can be upgraded to 10kVA by adding another LP 5kVA in parallel. This spread investment makes sure that you don???t have to invest in advance, but only when you need to.
GE???s unique RPA system has the following major advantages:
???RPA offers true redundancy because not only the power electronics are redundant, but also the batteries, the bypass circuit and the control logic,
???The RPA system is an option: you don???t have to buy it if you don???t need it.
g
Digital Energy??? LP Series
7.4PDM: Power Distribution Module
This Power Distribution Module (PDM) contains 4 x Nema
For more information please refer to the user manual that comes with the Power Distribution Module.
D
B
Fig. 23: Power Distribution Module
7.5Seismic anchors
Seismic anchors can be ordered separately; contact your local dealer.
g
Digital Energy??? LP Series
8 - Maintenance
8.1General
When used properly, the UPS is virtually maintenance free other than keeping the air inlets/outlets free from dust.
8.2Cooling fan
The expected operational life of the cooling fans is approximately 20,000 to 40,000 hours of continuous operation. A high ambient temperature will shorten this operational life.
8.3Batteries
The service life of the battery is from 3 to 6 years, depending on the operating temperature and on the number of discharge cycles.
As a healthy battery is essential to the performance of the UPS, an automatic battery test is performed regularly to ensure failsafe operation (see section 5.4.1). When the condition of the battery is critical, the warning signal will be activated (buzzer 1x per 8 secs, and alarm message 'Replace battery', see 5.3.2). The batteries must be replaced as soon as possible. Please contact your dealer. Use only UL recognised batteries (BAZR2), valve
regulated types.
NOTE: under certain circumstances a manual battery test can result in a false alarm: please see section 5.4.2
'QUICK BATTERY TEST'.
Regular deep battery tests are advised in order to
NOTE: All maintenance and service work, including battery replacement, should be performed by qualified service personnel.
For authorized service personnel only:
Never short the battery terminals. Shorting may cause the battery to burn. Avoid charging in a sealed container. Proper disposal of batteries is required: refer to your local codes for disposal requirements. Never dispose of batteries in a fire: they may explode. Never disassemble or reassemble batteries; their contents (electrolyte) may be extremely toxic. If exposed to electrolyte, wash immediately with plenty of water, if eye contact occurs flush with water and contact a physician.
8.4Safety
CAUTION:
When the
For your safety, only authorized service personnel may remove the cabinet cover.
8.5Storage
Always store the UPS in a dry location with the batteries in a fully charged state, storage temperature must be within
-if the storage temperature is within
-if the storage temperature is within
8.6Recycling the UPS at the end of service life
NOTE: This product has been designed to respect the environment, using materials and components respecting
GE Digital Energy, in compliance with environment protection recommends that the UPS equipment, at the end of its service life, must be recycled conforming to the local applicable regulations.
WARNING
The batteries contain lead, which is a dangerous substance for the environment. Therefore the batteries must be recycled correctly by specialized companies.
g
Digital Energy??? LP Series
9 - Troubleshooting
Whenever a malfunction occurs, first check external factors (e.g. connections, temperature, humidity or load) to determine whether the problem is caused by the unit itself or by its environment. Subsequently check whether the breakers/switches on the rear panel (fig. 19,
The front screen will indicate the problem and solution (if the problem is due to environmental circumstances). If the solution is not shown on the screen, please contact your dealer.
During the
(One of) the following messages can be displayed:
SELFTEST FAILURE
PCB POWER SUPPLY
SELFTEST FAILURE
AC ON INPUT
SELFTEST FAILURE
INT.BATTERY FUSE
SELFTEST FAILURE
EXT.BATTERY FUSE
SELFTEST FAILURE
BATTERY CHARGER
SELFTEST FAILURE
Uic TOO HIGH
SELFTEST FAILURE
TEMP TOO HIGH
SELFTEST FAILURE
Uba TOO LOW
SELFTEST FAILURE
Uic TOO LOW
SELFTEST FAILURE
Q4 NOT OK
One or more voltages of the internal power supply is (are) outside tolerance. Please contact your dealer.
An external AC voltage (not the UPSs output voltage) was detected on the output terminals. Please contact your dealer.
The internal battery fuse is defective. Please contact your dealer.
The battery extension circuit breaker is in 'the off' position. Please switch it to 'the on' position.
Malfunction of the battery charger. Please contact your dealer.
Malfunction of the input circuit: voltage delivered is too high. Please contact your dealer.
The temperature of (one of) the components is (still) too high. See section 5.3.2.
The battery voltage is too low to allow
Malfunction of input circuit: voltage delivered is too low. The batteries may be faulty or depleted. Wait for a few hours, leave the UPS switched on.*
Hardware output voltage detection 'Q4' is active. Please contact your dealer.
* If absence of input power (utility failure, maintenance work) is expected to last longer than a few hours, switch off the UPS to save battery power. If the UPS input power is absent for several days and the UPS remains on under
g
Digital Energy??? LP Series
10 - Specifications
-low/high DC voltage
-overtemperature
-overload / short circuit
The output is protected against connection to the utility supply * according to EN
g
Digital Energy??? LP Series
AUTOMATIC BYPASS SWITCH
The automatic switch provides transfer of the load to the utility voltage without any interruption of the supply. The transfer is initiated by a signal from the output converter protection circuit in case of an overload or high temperature.
When the conditions return to normal the load is automatically transferred back to the output converter. The automatic bypass switch can be disabled by the
Bypass voltage limits
Transfer transients
Frequency tracking range
Slew rate
BATTERY
Battery type
Nominal voltage (V) / capacity (Ah) Number of batteries
Capacity of standard battery set Battery recharge time
Battery service life Battery discharging
Runtime in minutes VA / Watts
1000 / 800
2000 / 1600
3000 / 2400
5000 / 4000
6000 / 4800
8000 / 6400
10000 / 8000
BATTERY EXTENSION PACKS
Sheet steel cubicle
Dimensions (hxwxd, mm)
Dimensions (hxwxd, inch)
Battery
Weight with battery (Kg)
Weight with battery (Lbs)
Battery pack A (voltage V / capacity Ah) Total capacity (Ah)
Typical runtime, 100% / 50% load, min. Number of packs required
Battery pack B (voltage V / capacity Ah) Total capacity (Ah)
Typical runtime, 100% / 50% load, min. Number of packs required
For more info see section 7.1
:
:typically 2% mean deviation over one half cycle.
:?? 2/4/6% of nominal (user selectable)
:max. 1Hz/sec or 5Hz/sec (user selectable)
:Sealed and maintenance free
:1.5 - 3 hours for 80% capacity
:up to 6 years (depending on operating conditions)
:self discharge current ??? 0.35 mA
discharge end voltage of the battery depending on the actual load 10.5Vdc < 0.2 CA till 9.0 Vdc > 2 CA
When the UPS is in sleeping mode the inverter will be switched off, battery charger and rectifier are in operation
:VSDA1
:537x313x590
:21.1x12.3x23.2
:240Vdc/7Ah or 240Vdc/14Ah
:73 or 123
:161 or 271
g
UPS Type
ENCLOSURE
Sheet steel cubicle Colour front Colour cabinet Protection
Dimensions (hxwxd, mm) Dimensions (hxwxd, inch) (height with castors)
Weight (with batteries, Kg) Weight (with batteries, Lbs)
GENERAL DESIGN CRITERIA
Mechanical
Humidity
Safety
Surge capability
EMC
ENVIRONMENT
Ambient temperature Audible noise at 1 meter
Digital Energy??? LP Series
:RAL 9006 (aluminum)
:RAL 9010 (white)
:IP 20
:IP20
:95% non condensing
:UL 1778; 2001,
EN
:6kV 1.2/50??s; 3kA 8/20??s
:FCC part 15, class A; EN
:
:40 - 50dB(A),
the audible noise is load and temperature dependent
g
Digital Energy??? LP Series
Dimensions Conduit Box
Center of Gravity
front
H
D
W
UPS cabinet, dimensions hxwxd: 680 x 310 x 710 mm
26.8 x 12.3 x 28.7 inch
Center of gravity, position: H = 275 mm / 10.8 inch W = 155 mm / 6.1 inch
D = 300 mm / 11.8 inch
g
Digital Energy??? LP Series
LP
g
Digital Energy??? LP Series
LP
h
w
LEVELLER
POSITION A: FIX UPS TO THE FLOOR
POSITION B: LIFT UPS CASTORS FROM THE FLOOR
d
MANUAL BYPASS SWITCH
NORMAL: POSITION 1
(LOAD ON UPS)
SERVICE: POSITION 2
(LOAD ON BYPASS)
INPUT/OUTPUT TERMINALS
OUTPUT INPUT
EARTH
CONNECTION
IS ESSENTIAL
CASTORS
CONDUIT BOX
CABLE ENTRY
5 - COMMON
9 - GENERAL ALARM
4 - NOT USED
8 - MAINS FAILURE
3 - SERIAL DATA IN / UPS SHUTDOWN
7 - PLUG&PLAY / RTS
2 - SERIAL DATA OUT
6 - BYPASS ACTIVE
1 - BATTERY LOW
BATTERY FUSES
CONTROLS / CIRCUIT BREAKERS
UPS UTILITY BYPASS
ON
OFF
BATTERY PACK CONNECTOR
OPTION SLOTS
RS232 / CONTACT, SEE BELOW
SNMP CARD OR RELAY CARD
RPA CARD
PARALLEL OPERATION
RS232 / CONTACT INTERFACE
BATTERY
DISCONNECTED
EMERGENCY
SHUTDOWN
g
Digital Energy??? LP Series
LP
d
MANUAL BYPASS SWITCH
NORMAL: POSITION 1
(LOAD ON UPS)
SERVICE: POSITION 2
(LOAD ON BYPASS)
INPUT/OUTPUT
OUTPUT INPUT
EARTH
CONNECTION
IS ESSENTIAL
h
CASTORS
INPUT TERMINALS
EARTH
CONNECTION
IS ESSENTIAL
LEVELLER
BATTERY FUSES
CONTROLS / CIRCUIT BREAKERS
UPS UTILITY BYPASS
ON
OFF
BATTERY PACK CONNECTOR
OPTION SLOTS
RS232 / CONTACT, SEE BELOW
SNMP CARD OR RELAY CARD
RPA CARD
PARALLEL OPERATION
RS232 / CONTACT INTERFACE
BATTERY
DISCONNECTED
EMERGENCY
SHUTDOWN
5 - COMMON
9 - GENERAL ALARM
4 - NOT USED
8 - MAINS FAILURE
3 - SERIAL DATA IN /
UPS SHUTDOWN 7 - PLUG&PLAY / RTS
2 - SERIAL DATA OUT
6 - BYPASS ACTIVE
1 - BATTERY LOW
POSITION A: FIX UPS TO THE FLOOR
POSITION B: LIFT UPS CASTORS FROM THE FLOOR