Home Comfort

FRA08EHT1

Through-The-Wall

Air Conditioner???/???Heater

Product Dimensions

More Easy-To-Use Features

Effortless??? Clean Filter

Our antibacterial filter reduces bacteria, room odors and other airborne particles for a cool, comfortable environment.

Multi-Speed Fan

Features three different fan speeds, for more cooling flexibility.

Sleep Mode

Quiet operation keeps you cool without keeping you awake. Plus, Sleep Mode gradually increases room temperature after being activated.

Quickly Cools

Quickly cool a room on hot days.

Comfort Control Design

Easily control the direction of your cool air, wherever your unit is.

Effortless??? Restart

Automatically resumes operating at its previous settings when power is restored to your unit.

Clean Filter Alert

Notifies you when your filter needs to be cleaned.

Signature Features

Effortless??? Temperature

Control

Our air conditioners maintain the preset room temperature, so you will remain comfortable at all times.

Ready-Select?? Controls

Easily select options with the touch of a button.

Power Cord

Comes with an extra long three-prong cord that makes extension cords unnecessary.

SpaceWise?? Adjustable Design

Optional Side Panels

Extend so you can adjust your unit to fit your window.

24-Hour On/Off Timer

Keep things cool on your schedule.

frigidaire.com

Home Comfort

FRA08EHT1 Through-The-Wall Air Conditioner???/???Heater

1Warranty 5 year sealed system???/???1 year full parts and labor.

Plug Type (NEMA)

5-15P

C

D

A

B

NOTE: For planning purposes only. Always consult local and national electric codes.

Refer to Product Installation Guide for detailed installation instructions on the web at frigidaire.com.

Accessories information available on the web at frigidaire.com

Home Comfort

FRA08EHT1 Through-The-Wall Air Conditioner???/???Heater

Plug Type (NEMA)

5-15P

Home Comfort Specifications

???Product Shipping Weight (approx.) ??? 73 Lbs.

???An electrical supply with grounded three-prong receptacle is required. The power supply circuit must be installed in accordance with current edition of National Electrical Code (ANSI/NFPA 70) and local codes & ordinances.

???Voltage Rating ??? 115V???/???60 Hz???/???15 Amps

???Amps @ 115 Volts = (Cool) 8 Amps???/???(Heat) 11.6 Amps

???Recommended Circuit Breaker ??? 15 Amps

???Unit equipped with 115V 3-wire power supply cord, NEMA plug type 5-15P, approximately 72" long.

???Unit???s increased performance characteristics result from two rear intakes. For unit to operate at maximum efficiency, carefully follow complete, detailed new or replacement installation instructions provided in Product Installation Guide on web.

???Unit requires rearward slope when installation is complete, to allow condensate to drain from rear of sleeve.

New Installation

???For new installation, Frigidaire?? Through-The-Wall 18" Sleeve Kit PN???#EA108T available. Recommended for proper installation.

???Through-the-wall installation requires 18" maximum wall thickness.

???For energy-saving purposes, install unit in shady location, preferably a northern exposure; and do not block airflow inside with blinds, curtains or furniture; or outside with shrubs, enclosures or other buildings.

USA ??? 10200 David Taylor Drive ??? Charlotte, NC 28262 ??? 1-800-FRIGIDAIRE ??? frigidaire.com CANADA ??? 5855 Terry Fox Way ??? Mississauga, ON L5V 3E4 ??? 1-800-265-8352 ??? frigidaire.ca

Replacement Installation

???When replacing existing air conditioner with new unit, refer to Product Installation Guide on web to identify existing wall-sleeve manufacturer and size compatibility. If proper installation and slope are suspect, then correct installation of Frigidaire?? Through-The-Wall 18" Sleeve Kit PN???#EA108T recommended.

???Use of existing wall sleeve to mount new unit requires original sleeve be in sound structural condition with rear grille that attaches securely, or rear flange that serves as stop for unit.

???Preferable installation option, for increased efficiency and possibility of drafts reduced, requires existing rear grille (mounted to sleeve) be replaced with new unit???s rear air-directional louvered grille (provided in accessory kit, shipped with unit). Non-preferable installation option of directly mounting rear louvered grille to unit can be considered, requiring grille be mounted to unit prior to sleeve installation.

???Existing decorative exterior grille may be left in place, provided that proper air-directional rear louvered grille is installed.

???For installation into larger existing sleeve, optional Trim Kit PN???# EA120T available.

Note: For planning purposes only. Refer to Product Installation Guide on the web at frigidaire.com for detailed instructions.

Optional Accessories

???Through-The-Wall 18" Sleeve Kit ??? (PN???# EA108T).

???Trim Kit (for larger existing sleeve) ??? (PN???# EA120T).

???Architectural-Style Exterior Louvered Grille ??? (PN???# EA109T).

Specifications subject to change.