FHWC3625MPEC3085K SS???/???W/???B
30"36"
Features
Signature Features
Effectively and quietly removes smoke, vapors and smells from the kitchen.
Cooking Surface Light
Provides ample illumination of the cooking surface.
Convertible Exhaust
Duct Options1
Ventilation is convertible to be either ducted outside, or recirculated inside requiring no ducting.
1??? Ventilation is convertible to be either ducted outside, or recirculated inside requiring no ducting. (Recirculated option requires use of a cover.)
2??? 7" round duct requires use of optional transition duct.
3??? For use on adequately wired 120V, dedicated circuit having
NOTE: Always consult local and national electric codes. Check local building codes for installation requirements, as they may vary per locale. Refer to Product Installation Guide for detailed installation instructions on the web at frigidaire.com.
Specifications subject to change.
Available in:
frigidaire.com
Overhead Hoods
FHWC3625M S???/???W/???B 36"
???Product Shipping Weight (Approx.) ??? 19 Lbs.
???
???Ventilation system can exhaust air outside, either vertically through roof or horizontally through wall. (Refer to Ducting Option Specifications for outside ventilation.). If ducting outside is not possible, the system can be alternately set to recirculate air inside, requiring use of recirculating kit, included with hood.
???Sones Rating ??? 5.8
???Voltage Rating ??? 120V???/???60 Hz???/???15 Amps
???Connected Load (kW Rating) @ 120 Volts = .72???kW
(For use on adequately wired 120V, dedicated circuit having
???Amps @ 120 Volts = 1.06 Amps
???Always consult local and national electric codes. Check local building codes for installation requirements, as they may vary per locale.
???Makeup air systems may be required by local building codes when using ventilation systems greater than specified CFM of air movement. Specified CFM varies per locale.
???Connect vent hood with copper wire only. (For installation
???Locate vent hood away from strong draft areas, such as windows, doors or strong heating vents.
???Minimum
???When installing vent hood under cabinets with recessed bottoms, two
Ducting Option Specifications
???Vent system MUST terminate outside through roof or wall; do NOT terminate into attic or other enclosed area.
???Exhaust Duct Required ???
to Product Installation Guide on web for calculations needed to determine total duct length.
???Installation of 7" Round Duct requires use of optional 7" Round Transition Duct (PN???# 5304487139) and can only be vented vertically.
???To provide efficient performance, length of vent system and number of elbows should be kept to minimum. Flexible vent greatly reduces performance and is NOT recommended.
???Use
???For cold weather installation, additional backdraft damper and thermal break should be installed. Thermal break will minimize conduction of outside temperatures as part of the vent system with damper on cold air side of break, as close as possible to where vent system enters heated portion of house.
???Refer to Product Installation Guide on web for detailed vent system preparation instructions.
Note: For planning purposes only. Refer to Product Installation Guide on the web at frigidaire.com for detailed instructions.
Optional Accessories
???7" Round Transition Duct ??? (PN???# 5304487139).
???Charcoal Filter ??? (PN???# 5304486302).
Accessories information available on the web at frigidaire.com