READ AND SAVE THESE INSTRUCTIONS
AVANT ECO???
Ceiling Fan Owner's Manual
Model Numbers
CF921BS00
CF921CK00
CF921GES00
CF921ORB00
!WARNING
WARNING: To avoid fire, shock, and serious personal injury, follow these instructions.
Safety Instructions
1.Read your owner???s manual carefully and keep it for future reference.
2.Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel.
3.Be careful of the fan and blades when cleaning, painting, or working near the fan. Always turn off the power to the ceiling fan before servicing.
4.Do not put anything into the fan blades while they are turning.
5.Do not operate reversing switch until fan blades have come to a complete stop.
Additional Safety Instructions for Installation
1.To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not operate fan without blades.
2.All wiring must be in accordance with the National Electrical Codes ???ANSI/NFPA
3.The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds. Use only U.L. outlet boxes listed as ???Acceptable for Fan Support of 22.7 kg. (50 lbs.) or less???, and use the mounting screws provided with the outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
4.The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling.
5.The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades.
6.Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do not know enough about electrical wiring, have your fan installed by a licensed electrician.
NOTE: All setscrews must be checked and
NOTE: This fan is suitable for use with
WARNING: To reduce the risk of fire or electric shock, this fan should only be used with fan speed control, Model No.
WARNING: To avoid fire, shock or injury, do not use an Emerson or any other brand of control not specifically approved for this fan.
WARNING: This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.
WARNING: To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.
WARNING: To reduce the risk of electrical shock, this fan must be installed with an isolating wall control/switch.
DATE CODE:
The date code of this fan may be found on the box, stamped in ink on a white label. You should record this data above and keep it in a safe place for future use.
EMERSON QUICK START GUIDE
!WARNING
Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse or circuit breaker box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.
2.The fan must be hung with at least 7??? of clearance from floor to ceiling.
3.Attach the hanger bracket to the outlet box.
4.Seat the hanger ball/downrod assembly on the hanger bracket.
EMERSON QUICK START GUIDE
Wiring Ceiling Fan (page 10)
1.Connect the green grounding lead from the hanger ball and the green grounding lead from the hanger bracket to the grounding conductor of supply (this may be a bare wire or wire with green colored insulation). Securely connect wires with wire connectors supplied.
NOTE: If you are using an Emerson Light Fixture with your fan, see Light Fixture Owner???s Manual for wiring.
2.Securely connect the fan motor white wire to the supply white (neutral) wire using wire connector supplied. Securely connect the fan motor black wire to the supply black (hot) wire using wire connector supplied.
3.After connections have been made, turn leads upward and carefully push leads into the outlet box, with the white and green leads on one side of the outlet box and the black on the other side of the outlet box.
Installation of Ceiling Cover (page 10)
1.Separate the grounded white neutral and green wires on one side of the outlet box from the ungrounded black wire on the other side of the outlet box
2. Insert the grounded green and white wires into one side of the outlet box, and the ungrounded black wire into the other side of the outlet box.
3. Screw the two threaded studs into the tapped holes in the hanger bracket.
4. Install the ceiling cover onto the hanger bracket. using the studs, lock washers and knurled nuts supplied.
Programming and Operation of Remote Control (pages 11 and 12)
1. The receiver must be programmed within 2 minutes of restoring electricity to the fan. Program the receiver code by pushing and holding down the remote control OFF button for
2. If programming fails, shut off and turn on the electricity at the wall switch to reset the receiver. Repeat Step 1 above.
3. If programming continues to fail, change the remote code and repeat Steps 1 and 2 as necessary until the fan successfully completes the programming procedure.
NOTE: Fan installation must be completed, including the installation of the fan blades, before testing the remote control.
4.Your SR600 Fan/Light remote control has full control of your fan speed, air flow direction and light intensity.
*For additional installation review full instructions on page 12.
This Manual Is Designed to Make it as Easy as Possible for You to Assemble, Install, Operate and Maintain Your Ceiling Fan
Tools Needed for Assembly
MATERIALS
Wiring outlet box and box connectors must be of type required by the local code. The minimum wire would be a
!WARNING
Before assembly your ceiling fan, refer to section on proper method of wiring your fan (page 10). If you feel you do not have enough wiring knowledge or experience, have your fan installed by a licensed electrician.
Unpacking Instructions
!WARNING
Do not install or use fan if any part is damaged or missing. Call
!WARNING
This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.
1.Check to see that you have received the following parts:
NOTE: If you are uncertain of part description, refer to exploded view illustration.
a.Fan motor assembly
b.One switch housing assembly
c.One ceiling cover
d.Five blade flanges
e.One hanger ball/downrod assembly
f.One hanger bracket
g.One coupling cover
h.One remote control
i.One loose parts bag containing:
1.
2.One
3.One
4.One
5.Three wire connectors
6.Two threaded studs
7.Two knurled knobs
8.Two lockwashers
9.One clevis pin
10.One hairpin clip
11.One balancing kit
NOTE: Place the parts from the loose parts bags in a small container to keep them from being lost. If any parts are missing, contact your local retailer or catalog outlet for replacement before proceeding.
2.Remove the fan assembly from the protective plastic bag. Place the fan assembly into the upper foam pad with the bottom of the motor facing up.
The upper foam pad serves as a holder for the fan during the first stages of assembly.
Electrical Requirements
Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit.
The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds.
!WARNING
To reduce the risk of fire, electrical shock, or personal injury, mount fan to outlet box marked ???Acceptable for Fan Support of 22.7 kg. (50 lbs.) or less???, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
!WARNING
Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.
!WARNING
To avoid fire or shock, follow all wiring instructions carefully. Any electrical work not described in these instructions should be done or approved by a licensed electrician.
If your fan is to replace an existing ceiling light fixture, turn electricity off at the main fuse box at this time and remove the existing light fixture.
How to Put Your Ceiling Fan Together
1.Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod (Figure 1). Remove the pin from the downrod, then remove the hanger ball. Retain the pin and hanger ball for reinstallation in Step 4.
2.Separate, untwist and unkink the two 80??? motor leads. Route the motor lead wires through the downrod. Remove the upper setscrew from the motor coupling. Align the clevis pin holes in the downrod with the holes in the motor coupling. Install the clevis pin and secure with the hairpin clip (Figure 2). The clevis pin must go through the holes in the motor coupling and the holes in the downrod. Be sure to push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin. The hairpin clip must be properly installed to prevent the clevis pin from working loose. Pull on the downrod to make sure the clevis pin is properly installed. Reinstall the upper setscrew in the motor coupling. Check that the lower setscrew is tightened securely (Figure 2).
NOTE: The setscrews must be properly installed as described above, or fan wobble could result.
!WARNING
It is critical that the clevis pin in the motor coupling is properly installed and the setscrews securely tightened. Failure to verify that the pin and setscrews are properly installed could result in the fan falling.
NOTE: If LKU100 is being assembled, see Page 13, ???Optional Accent Light Kit Installation??? of instruction procedures.
PIN
HANGER
BALL
SETSCREW
DOWNROD
Figure 1
MOTOR
COUPLING
HAIRPIN
UPPERCLIP
SETSCREW
Figure 2
How to Put Your Ceiling Fan Together (continued)
3.Make sure the grommet is properly installed in the coupling cover, then slide the coupling cover on the downrod until it rests on the motor housing. Place the ceiling cover over the downrod. Be sure that the ceiling cover and the coupling cover are both oriented correctly (Figure 3).
4.Reinstall the hanger ball (Figure 3) on the downrod as follows. Route the two 80??? motor leads through the hanger ball. Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball. Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball. A loose setscrew could create fan wobble.
!WARNING
It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened. Failure to verify that the pin and setscrew are properly installed could result in the fan falling.
PIN
HANGER
BALL
CEILING
COVER
COUPLING COVER
Figure 3
5.The fan comes with black and white leads that are 80??? long. Before installing fan, measure up approximately 6 to
6.Carefully turn the partially assembled ceiling fan over and set it on the shipping styrofoam for blade installation.
7.Remove the shipping spacers and the spacer attachment screws from the motor before installation of blade assemblies. Discard the spacers and spacer screws (Figure 4).
8.Mount blade flanges to fan blades (sold separately) using four
NOTE: Some accessory blades available are supplied with shorter screws. These shorter screws MUST be used to assemble the blades to flanges.
NOTE: Take care not to scratch fan housing when installing blades.
NOTE: Remove and discard the four shipping spacers and screws from the motor hub.
9.Loosely attach one blade assembly to the motor hub using the two
10.The blade flanges have an interlocking feature that must be fully engaged before tightening the screw. Make sure all the flanges are properly engaged and then tighten the flange screws. If one of the flanges does not seat properly on the motor hub, loosen the adjacent flange screws,
CAPTIVE SCREW
LOCKWASHER
SWITCH HOUSING
MOUNTING PLATE HOLE
How to Put Your Ceiling Fan Together (continued)
11.Remove the four switch housing mounting screws (Figure 7) from the switch housing plate. Position the switch housing assembly on the switch housing plate and align the holes in the switch housing assembly with the holes in the plate. Secure the switch housing assembly by installing the four screws (Figure 7).
NOTE: Tuck in both the blue and white wires carefully under the switch housing cover
!WARNING
To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.
SWITCH
HOUSING
ASSEMBLY
Figure 7
MOUNTING SCREWS (4)
12.You have now completed the assembly of your new ceiling fan. You can now proceed with hanging and wiring your fan.
How to Hang Your Ceiling Fan
!WARNING
The fan must be hung with at least 7' of clearance from floor to blades (Figure 8).
!WARNING
The outlet box and joist must be securely mounted and capable of supporting at least 50 lbs. Use only a U.L. outlet box listed as ???Acceptable for Fan Support of 22.7 kg. (50 lbs.) or less???.
!WARNING
To reduce the risk of fire, electrical shock, or personal injury, mount fan to outlet box marked ???Acceptable for Fan Support of 22.7 kg. (50 lbs.) or less???, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
1.Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box. (Figure 9.)
2.Carefully lift the fan and seat the hanger ball/downrod assembly on the hanger bracket that was just attached to the outlet box (Figure 9). Be sure the groove in the ball is lined up with tab on the hanger bracket (Figure 10).
!WARNING
Hanger bracket must seat firmly against outlet box. If the outlet box is recessed, remove wall board until bracket contacts box. If bracket and/or outlet box are not securely attached, the fan could wobble or fall.
NOTE: CEILING COVER
OMITTED FOR CLARITY.OUTLET
BOX
HANGER
BRACKET
HANGER BALL/
!WARNING
Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard.
!WARNING
To avoid possible fire or shock, do not pinch wires between the hanger ball/downrod assembly and hanger bracket.
How to Wire Your Ceiling Fan
If you feel that you do not have enough electrical wiring knowledge or experience, have your fan installed by a licensed electrician.
!WARNING
To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. NOTE: If you are not sure if the outlet box is grounded, contact a licensed electrician for advice, as it must be grounded for safe operation.
1.Connect the green grounding lead from the hanger ball and the green grounding lead from the hanger bracket to the grounding conductor of supply (this may be a bare wire or wire with green colored insulation). Securely connect wires with wire connectors supplied.
NOTE: If you are using an Emerson Light Fixture with your fan, see Light Fixture Owner???s Manual for wiring.
2.Securely connect the fan motor white wire to the supply white (neutral) wire using wire connector supplied (Figure 11). Securely connect the fan motor black wire to the supply black (hot) wire using wire connector supplied (Figure 11). After connections have been made, turn leads upward and carefully push leads into the outlet box, with the white and green leads on one side of the outlet box and the black leads on the other side of the outlet box.
!WARNING
Check to see that all connections are tight, including ground, and that no bare wire is visible at the wire connectors, except for the ground wire. Do not operate fan until blades are in place. Noise and fan damage could result.
3.Screw the two threaded studs (supplied) into the tapped holes in the hanger bracket.
4.Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the ceiling cover (Figure 12).
5.Secure the ceiling cover in place by sliding lockwashers over the threaded studs and installing the two knurled knobs (supplied). (Figure 12). Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling and the hole in the ceiling cover is clear of the downrod. Your fan is now wired to be turned on and off from the fan switch.
!WARNING
To avoid possible fire or shock, make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling.
BLACK
GROUND FAN WIRE
WIRE
CEILING COVER
THREADED STUDS (2)
LOCKWASHERS (2)
KNURLED KNOBS (2)
Figure 12
Installation of Remote Control Battery
Your Emerson Ceiling Fan/Light SR600 Remote Control consists of
The remote control transmitter is powered by two AAA alkaline batteries (included). To prevent possible damage if the batteries should leak, be sure to remove the batteries when the control is not to be used for an extended period of time.
Code switches in the transmitter and receiver may be set in 32 different positions. If your fan and light go on and off without using your control, you may be getting interference from other remote units such as garage door openers, car alarms or security systems. To remedy this situations, simply change the combination code in your transmitter and follow procedures for Setting Operating Frequency of Remote Control.
Preset Memory Feature
Your Emerson receiver is equipped with a preset memory feature. If the AC supply to the receiver is powered through a wall switch, when the switch is turned OFF, the control will remember the light intensity and fan speed. When the switch is turned back ON the light and fan will resume operation as they were prior to the switch being turned OFF.
1.Remove the battery cover by pressing firmly below the arrow and sliding the cover off the control (Figure 13).
2.Install two AAA alkaline batteries and reinstall the battery cover.
REMOTE CONTROL
LEVERS
TWO AAA
BATTERIES
CODE
SWITCHES
Figure 13
Setting Operating Frequency of Remote Control
Your remote control has code switches which must be set in one of 32 possible code combinations. The five levers (numbered 1, 2, 3, 4, and 5) on the switches are
1. Slide the five switch levers in the remote control to your choice of ON (up) or down positions. Use a
2.When power is restored, push and hold the fan OFF button ( ) for 3 to 5 seconds to set the code
in the reliever.
NOTE: The remote/receiver must be programmed within 2 minutes of restoring electricity to the fan.
Operation of Your Remote Control
!WARNING
Fan installation must be completed, including the installation of the fan blades, before testing the remote control.
Your SR600 Fan/Light remote control (Figure 18) has full control of your fan speed, air flow direction and light intensity.
1.If airflow is desired in the opposite direction, press
the () button on the wall control. The fan must be operating at any speed for the reverse button to function. The blades will turn in the opposite direction and reverse the airflow.
2.To set the desired fan speed, press the () button to decrease the speed and the ( ) to increase the speed. The LED display will light up to indicate the new speed selected.
3.To turn the downlight on, press and release the
() button. The light will turn on at the light intensity previously selected.
4.To turn the uplight on, press and release the ( ) button. The light will turn on at the light intensity previously selected.
5.To vary the intensity of the light, hold the DN or UP button down until the desired light intensity is reached, then release the button.
6.The sixth switch marked ON and I is for dimming control of lights: Set switch to ON to allow for dimming of the lights. Set switch to I for no dimming of the lights such as for fluorescent bulbs.
Installation of Storage Bracket for SR600 Remote Control
A storage bracket is provided for holding your remote control when not in use. If you desire to use the bracket, install it on a wall that is away from excess heat or humidity (Figure 15)
TO INSTALL BRACKET TO WALL:
SLIDE THE COVER UP TO EXPOSE THE SCREW
HOLES FOR INSTALLATION
COVER
WALL
BRACKET
High Speed Conditioning of Fan Control
IMPORTANT: The following steps must be completed immediately following the frequency programming of the ceiling fan.
1.Press the ( ) speed button until all 6 LED indicators are lit. Let the fan operate on high speed for 2 minutes without interruption.
2. After 2 minutes, press the reverse ( ) button and allow the fan to operate uninterrupted for 2 minutes at high speed.
3. High speed conditioning is now complete.
Optional Accent Kit Installation
CAUTION: To reduce the risk of electric shock, disconnect the electrical supply circuit to the fan before installing light kit assembly.
1.Remove the three coupling cover screws and slide the coupling cover up the downrod for installation of light kit assembly (Figure 16). Retain the three screws for later installation of coupling cover.
2.Position the light kit assembly so that the opening of the light kit assembly slides through the downrod. Align the mounting holes of the light kit assembly to the motor assembly (Figure 17).
NOTE: Be sure the light kit assembly connector is located close to the motor assembly connector for ease of installation.
3.Install the light kit assembly to the motor assembly using three light kit assembly mounting screws (Figure 17).
4.Securely connect the light kit assembly connector to the motor assembly connector (Figure 18).
5.Screw the four
!WARNING
To avoid possible fire hazard, do not exceed four
COUPLING COVER SCREWS (3)
(RETAIN FOR LATER
INSTALLATION)
Figure 16
LIGHT KIT
ASSEMBLY
SCREW (3)
Figure 17
COUPLING
COVER
UPPER FAN
MOTOR
ASSEMBLY
LIGHT KIT
ASSEMBLY
UPPER FAN MOTOR
ASSEMBLY
6.Carefully tuck all wiring and wire connectors close to the downrod and slide the coupling cover over the wires.
NOTE: Be sure light kit assembly wires are positioned in the dimpled wireway of the upper housing to avoid pinching of the wires during installation of coupling cover.
CAUTION: Before installing and tightening the screws, be sure there are no wires pinched between the light kit assembly/motor assembly and coupling cover.
7.Reinstall the three coupling cover screws to secure the coupling cover (Figure 19).
LIGHT KIT ASSEMBLY
CONNECTOR
Figure 18
COUPLING COVER
REINSTALL COUPLING
COVER SCREWS (3)
Figure 19
Maintenance
IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan
Periodic cleaning of your new ceiling fan is the only maintenance that is needed.
When cleaning, use only a soft brush or lint free cloth to avoid scratching the finish.
Abrasive cleaning agents are not required and should be avoided to prevent damage to finish.
!WARNING
Do not use water when cleaning your ceiling fan. It could damage the motor or the blades and create the possibility of an electrical shock.
Accessories
1.Ceiling Fan Light Kits (see store or catalog).
2.Ceiling Fan/Light Controls (see store or catalog).
3.Downrod Extension Kits (see store or catalog).
4.Ceiling Fan Blades (see store or catalog).
!WARNING
The use of any other control not specifically approved for this fan could result in fire, shock and personal injury.
!WARNING
This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.
INSTRUCTION TO THE USER (if device contains a digital device)
This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
???Reorient or relocate the receiving antenna.
???Increase the separation between the equipment and receiver.
???Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
???Consult the dealer or an experienced radio/TV technician for help.
This equipment has been certified to comply with the limits for a class B computing device, pursuant to FCC Rules. In order to maintain compliance with FCC regulations, shielded cables must be used with this equipment. Operation with
This Class B digital apparatus meets all requirements of the Canadian
Trouble Shooting
!WARNING: For your own safety, turn off power at fuse box or circuit breaker before trouble shooting your fan.
Repair Parts
4
2
3
15
8
9
10
BLADES SOLD
SEPARATELY
16
13
5
19
18
11
17
12
Repair Parts Listing
Before discarding packaging material, be certain all parts have been removed.
HOW TO ORDER REPAIR PARTS
WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION:
??? PART NUMBER ??? PART DESCRIPTION ??? NAME OF ITEM ??? MODEL NUMBER For repair parts, phone
Notes
Notes
LIMITED WARRANTY
What The Warranty Covers:
This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials. You must be the original purchaser or user of the product to be covered.
What The Period Of Coverage Is:
As it applies to the motor, this warranty will last for the lifetime of your ceiling fan. All other components and accessories are covered by this warranty for one year from the date you purchased your ceiling fan. ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, MADE WITH RESPECT TO COMPONENTS AND
ACCESSORIES IS ALSO LIMITED TO ONE YEAR.
What Will Emerson Electric Co. Do To Correct Problems:
Emerson Electric Co. will replace a defective Emerson Air Comfort Ceiling Fan motor, blade, component or other accessory at no charge to you. If repair of the motor or blades is not practical or possible within a reasonable time and no replacement can be provided, Emerson will refund the actual purchase price of your fan. WE WILL SHIP THE REPAIRED PRODUCT OR
REPLACEMENT TO YOU AT NO CHARGE, BUT YOU ARE RESPONSIBLE FOR ALL COSTS OR REMOVAL, REINSTALLATION
AND SHIPPING OF THE PRODUCT TO EMERSON ELECTRIC CO.
How Can You Get Service:
YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE CEILING FAN TO OBTAIN LIMITED WARRANTY SERVICE. KEEP YOUR RECEIPT OR OTHER PROOF OF PURCHASE. You can return the product to our factory or to your nearest authorized service center.
???To return the product to the factory, obtain a return authorization and service identification tag by writing to Air Comfort Products, Division of Emerson Electric Electric Co., 8100 W. Florissant Ave., St. Louis, MO 63136. Include all model numbers shown on the product with your request.
???To return the product to an authorized service center, call
You will be responsible for all insurance, freight or other transportation charges to our factory or authorized service center. Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage.
What Is Not Covered:
The glass globes and light bulbs of your ceiling fan are not covered by this warranty. This warranty also does not cover any defects, malfunctions or failures caused by:
???Repairs by persons not authorized by Emerson Electric Co.,
???Use of parts or accessories not authorized by Emerson Electric Co.,
???Mishandling, improper installation, modifications or damage to your ceiling fan while in your possession, or
???Unreasonable use, misuse, abuse, including failing to do reasonable and necessary maintenance, and normal wear and tear. Additionally, this warranty and any implied warranty of merchantability or fitness for a particular purpose are voided when:
???The original purchaser or user ceases to own the product, or
???The fan is moved from its original point of installation.
This warranty is only valid within the 50 states of the United States and the District of Columbia. No other written or oral warranties apply, and no employee, agent, dealer or other person is authorized to give any warranties on behalf of Emerson Electric Co.
REPAIR, REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS WARRANTY AND
EMERSON IS NOT RESPONSIBLE FOR DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES. Incidental damages include but are not limited to such damages as loss of time and loss of use. Consequential damages include but are not limited to the cost of repairing or replacing other property which was damaged if this product does not work properly.
How State Law Relates To The Warranty:
Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
Air Comfort Products
DIVISION OF EMERSON ELECTRIC CO. 8100 W. Florissant ??? St. Louis, MO 63136
ETL Model No.: CF921