MODELS: VFB080C4L1 / VFB050C4L1
Page 1.
INSTALLATION AND OPERATING INSTRUCTIONS
VENTILATION FAN / LIGHT
READ AND SAVE THESE INSTRUCTIONS
GENERAL SAFETY INFORMATION
1.Make sure that the electric service supply voltage is AC 120V, 60Hz.
2.Follow all local electrical and safety codes, as well as the Nation Electrical Code (NEC) and the Occupation Safety and Healthy Act (OSHA).
3.Always disconnect the power source before working on or near the ventilating fan, motor or junction box.
4.Protect the power cord from sharp edges, oil, grease, hot surfaces, chemicals or other objects.
11.Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
12.NEVER place a switch where it can be reached from a tub or shower.
13.Not to be installed in a ceiling thermally insulated to a value greater than R40. (This is required for installation in Canada only)
5.Do not kink the power cord.
6.Do not install the unit where ducts are configured as shown in Fig. A.
7.Provide suction parts with proper ventilation.
8.This unit is UL listed for use over a bathtub or shower when installed in a GFCI protected branch circuit.
9.These ventilating fans are intended for residential usage only.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1.Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.
2.Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3.Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including
4.Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer???s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating Refrigeration and Air Conditioning Engineers (ASHRAE) and local code authorities.
5.When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
6.Ducted ventilating fan must always be vented to the outdoors.
7.Do not install this ventilating fan where air temperature may exceed 40??C (104??F).
8.If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit Interrupter) ??? protected branch circuit.
9.These models are UL listed for tub and shower enclosures.
10.Do not use this unit with any other
Fig. A
CAUTION
1.For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2.Not for use in cooking area. (Fig. B)
3.This product must be properly grounded.
Cooking area
Do not install above or inside this area
Fig. B
SUPPLIED ACCESSORIES
1. INSTALLATIONS
MOUNT HOUSING WITH FLANGE:
Screw housing to joist through lowest holes in each mounting flange, then through the other holes.
2. DUCT CONNECTION
3. CONNECT WIRING
HOUSE ELECTRICAL BOX LIGHT/FAN ELECTRICAL BOX
4. TEST RUN & GRILLE ATTACHMENT
Screw M4 x 6
6. MAINTENANCE
WARNING:
Disconnect power source before working on unit. Routine maintenance must be done every year.???
CAUTION:
1.Never use gasoline, benzene, thinner or any other such chemicals for cleaning the ventilating fan.
2.Do not allow water to enter motor.
3.Do not soak resin parts in water over 60??C.
CLEANING???
1.Open lens cover. Remove the light bulbs carefully. Disassemble the lock screw, lock nut and light power connections to remove grille.
2.Wash and clean grille. CAUTION: Do not let water into the lamp base. (Use
3.Remove dust and dirt from ventilating fan using a vacuum cleaner.
4.Using a cloth dampened with kitchen detergent, remove any dirt from ventilating fan. Wipe dry with new cloth.
5.Replace grille.
DIMENSIONS
MODELS: VFB080C4L1 / VFB050C4L1
Page 2.
WARRANTY
DELTA ELECTRONICS THREE YEAR LIMITED
WARRANTY
Delta Electronics Inc.(???Delta Electronics???) warrants to the original consumer purchaser in the USA that the Breez ventilation fan products will be free from defects in material or workmanship. This warranty is limited to three (3) years from the original date of purchase.
Limitations and Exclusions
1.During the warranty period, a replacement for any defective product will be supplied free of charge for installation by the consumer. The warranty provided herein does not cover charges for labor or other costs incurred in the troubleshooting, repair, removal, and installation service.
2.All returns of defective parts or products must include the product model number, and must be made through an authorized Delta Electronics distributor. Authorized returns must be shipped prepaid. Repaired or replacement products will be shipped by Delta Electronics F.O.B. shipping point.
3.Delta Electronics shall not be liable for any indirect, incidental, consequential, punitive, or special damages arising out of or in connection with products use or performance, regardless of the form of action whether in contract, tort (including negligence), strict product liability or otherwise.
4.This warranty does not extend to fluorescent lamp starters and tubes.
5.The warranty does not cover if user does not comply with manufacture???s installation manual.
6.To qualify for warranty service, you must notify Delta Electronics at the address or telephone number below.
7.Delta Electronics shall have no liability to the original
Address: 4405 Cushing Parkway, Fremont, CA 94538
US Toll Free Number:
5. OPERATION
Turn on the power switch to operate ON or OFF, and LED indicator is amber. Turn on the power to operate main light on/off.
Turn on the power switch to operate ON or OFF, and LED indicator is green. Turn on the power to operate main light on/off.
SPECIFICATIONS
Note: Design and specifications subject to change without notice.