Dell Storage Center
SCv2000 and SCv2020 Storage System
Deployment Guide
Notes, Cautions, and Warnings
NOTE: A NOTE indicates important information that helps you make better use of your computer.
CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem.
WARNING: A WARNING indicates a potential for property damage, personal injury, or death.
Copyright ?? 2015 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws. Dell??? and the Dell logo are trademarks of Dell Inc. in the United States and/or other jurisdictions. All other marks and names mentioned herein may be trademarks of their respective companies.
2015 - 04
Rev. A00
Contents
3
4
5
6
About this Guide
This guide describes the features and technical specifications of an SCv2000/SCv2020 storage system.
Revision History
Document Number: 8X7FK
Audience
The information provided in this Deployment Guide is intended for storage or network administrators and deployment personnel.
Contacting Dell
Dell provides several online and
To contact Dell for sales, technical support, or customer service issues go to www.dell.com/support.
???For customized support, enter your system Service Tag on the support page and click Submit.
???For general support, browse the product list on the support page and select your product.
Related Publications
The following documentation is available for the SCv2000/SCv2020 storage system.
???Dell Storage Center SCv2000 and SCv2020 Storage System Getting Started Guide
Provides information about an SCv2000/SCv2020 storage system, such as installation instructions and technical specifications.
???Dell Storage Center SCv2000 and SCv2020 Storage System Owner???s Manual
Provides information about an SCv2000/SCv2020 storage system, such as hardware features, replacing customer replaceable components, and technical specifications.
???Dell Storage Center SCv2000 Series Virtual Media Update Instructions
Describes how to install Storage Center software on an SCv2000/SCv2020 storage system using virtual media. Installing Storage Center software using the Storage Center Virtual Media option is intended for use only by sites that cannot update Storage Center using standard methods.
???Dell Storage Center Release Notes
Contains information about new features and known and resolved issues for the Storage Center software.
7
???Dell Storage Client Administrator???s Guide
Provides information about the Dell Storage Client and how it can be used to manage a Storage Center.
???Dell Storage Center Software Update Guide
Describes how to upgrade Storage Center software from an earlier version to the current version.
???Dell Storage Center Command Utility Reference Guide
Provides instructions for using the Storage Center Command Utility. The Command Utility provides a
???Dell Storage Center Command Set for Windows PowerShell
Provides instructions for getting started with Windows PowerShell cmdlets and scripting objects that interact with the Storage Center via the PowerShell interactive shell, scripts, and PowerShell hosting applications. Help for individual cmdlets is available online.
???Dell TechCenter
Provides technical white papers, best practice guides, and frequently asked questions about Dell Storage products. Go to: http://en.community.dell.com/techcenter/storage/.
8
1
About the SCv2000/SCv2020 Storage
System
The SCv2000/SCv2020 storage system provides the central processing capabilities for the Storage Center Operating System (OS) and management of RAID storage.
The SCv2000/SCv2020 storage system holds the physical disks that provide storage for the Storage Center. If additional storage is needed, the SCv2000/SCv2020 also supports SC100/SC120 expansion enclosures.
Storage Center Hardware Components
The Storage Center described in this document consists of an SCv2000 or SCv2020 storage system,
The SCv2000/SCv2020 storage system supports multiple SC100/SC120 expansion enclosures to allow for storage expansion.
NOTE: The cabling between the storage system, switches, and host servers is referred to as front??? end connectivity. The cabling between the storage system and expansion enclosures is referred to as
SCv2000/SCv2020 Storage System
The SCv2000 and SCv2020 are 2U storage systems with
The SCv2000/SCv2020 storage system contains two redundant power supply/cooling fan modules and up to two storage controllers with multiple IO ports that provide communication with servers and expansion enclosures.
Switches
Dell offers
The SCv2000/SCv2020 supports Fibre Channel (FC) and Ethernet switches, which provide robust connectivity to servers and allow for the use of redundant transport paths. Fibre Channel (FC) or Ethernet switches can provide connectivity to a remote Storage Center to allow for replication of data. In addition, Ethernet switches provide connectivity to a management network to allow configuration, administration, and management of the Storage Center.
Expansion Enclosures
An SCv2000/SCv2020 storage system supports multiple SC100/SC120 expansion enclosures. The expansion enclosures allow the data storage capabilities of the SCv2000/SCv2020 to be expanded beyond the 12 or 24 internal drives in the storage system chassis.
The SCv2000/SCv2020 storage system supports a total of 168 drives per Storage Center system. This total includes the drives in the SCv2000/SCv2020 storage system chassis and the drives in SC100/SC120 expansion enclosures chassis.
???The SCv2000 supports up to thirteen SC100 expansion enclosures, up to six SC120 expansion enclosures, or any combination of SC100/SC120 expansion enclosures as long as the total drive count of the system does not exceed 168.
???The SCv2020 supports up to twelve SC100 expansion enclosures, up to six SC120 expansion enclosures, or any combination of SC100/SC120 expansion enclosures as long as the total drive count of the system does not exceed 168.
Storage Center Architecture Options
A Storage Center with an SCv2000/SCv2020 storage system can be deployed in two configurations:
???An SCv2000/SCv2020 storage system without SC100/SC120 expansion enclosures.
Figure 1. SCv2000/SCv2020 without Expansion Enclosures
???An SCv2000/SCv2020 storage system with one or more SC100/SC120 expansion enclosures.
NOTE: A storage system with a single storage controller cannot be deployed with expansion enclosures. The storage system must have dual storage controllers to deploy expansion enclosures.
Figure 2. SCv2000/SCv2020 with Two Expansion Enclosures
Storage Center Replication
Storage Center sites can be collocated or remotely connected and data can be replicated between sites. Storage Center replication can duplicate volume data to another site in support a disaster recovery plan or to provide local access to a remote data volume. Typically, data is replicated remotely as part of an overall disaster avoidance or recovery plan.
The SCv2000 series Storage Center supports replication to other SCv2000 series Storage Centers. However, an Enterprise Manager Data Collector must be used to replicate data between the storage systems.
???For more information on installing an Enterprise Manager Data Collector, see the Dell Enterprise Manager Installation Guide.
???For more information on managing the Data Collector and setting up replications, see the Dell Enterprise Manager Administrator???s Guide.
Storage Center Communication
A Storage Center uses multiple types of communication for both data transfer and administrative functions.
Storage Center communication is classified into three types: front end, back end, and system administration.
???Fibre Channel: Hosts, servers, or Network Attached Storage (NAS) appliances access storage by connecting to the storage system Fibre Channel ports through one or more Fibre Channel switches. Connecting host servers directly to the storage system without using Fibre Channel switches is not supported.
When replication is licensed, the SCv2000/SCv2020 can use the Fibre Channel ports to replicate data to another Storage Center.
???iSCSI: Hosts, servers, or Network Attached Storage (NAS) appliances access storage by connecting to the storage system iSCSI ports through one or more Ethernet switches. Connecting host servers directly to the storage system without using Ethernet switches is not supported.
When replication is licensed, the SCv2000/SCv2020 can use the iSCSI ports to replicate data to another Storage Center
NOTE: If replication is licensed, the SCv2000/SCv2020 can use the embedded REPL port to perform iSCSI replication to another SCv2000 series Storage Center.
If replication is licensed and the Flex Port license is installed, the SCv2000/SCv2020 can use the embedded MGMT port to perform iSCSI replication to another SCv2000 series Storage Center. In addition, the SCv2000/SCv2020 can use the embedded MGMT and REPL ports as
???SAS: Hosts or servers access storage by connecting directly to the storage system SAS ports.
NOTE: The
SCv2000/SCv2020 Storage System with Fibre Channel
An SCv2000/SCv2020 storage system with Fibre Channel
Figure 3. Storage System with Fibre Channel
SCv2000/SCv2020 Storage System with iSCSI
An SCv2000/SCv2020 storage system with iSCSI
Figure 4. Storage System with iSCSI
SCv2000/SCv2020 Storage System with SAS
An SCv2000/SCv2020 storage system with SAS
Figure 5. Storage System with SAS
The SCv2000/SCv2020 supports SAS connectivity to multiple SC100/SC120 expansion enclosures.
System Administration
To perform system administration, the Storage Center communicates with computers using the Ethernet management (MGMT) port.
The Ethernet management port is used for Storage Center configuration, administration, and management.
NOTE: The baseboard management controller (BMC) does not have a separate physical port on the SCv2000/SCv2020. The BMC is accessed through the same Ethernet management port that is used for Storage Center configuration, administration, and management.
SCv2000/SCv2020 Storage System Hardware
The SCv2000/SCv2020 storage system ships with Dell Enterprise drives, two power supply/cooling fan modules, and either one storage controller or two redundant storage controllers.
Each storage controller contains the
SCv2000/SCv2020 Storage System Front Panel Features and Indicators
The front panel of the SCv2000/SCv2020 contains power and status indicators, a system identification button, and a
In addition, the hard drives are installed and removed through the front of the storage system chassis.
Figure 6. SCv2000 Front Panel View
???Off: No power
???On steady blue: Power is on and firmware is running
???Blinking blue:Storage system is busy booting or updating
???On steady amber: Hardware detected fault
???Blinking amber: Software detected fault
SCv2000/SCv2020
The back panel of the SCv2000/SCv2020 shows the storage controller indicators and power supply indicators.
Figure 7. SCv2000/SCv2020 Back Panel View
4Cooling fan fault indicator (2)
???REPL port: Embedded iSCSI port, which is typically used for replication to another Storage Center
???Off: Normal operation
???Steady amber: Fan fault or there is a problem communicating with the PSU
???Blinking amber: PSU is in programming mode
5AC power fault indicator (2)
???Off: Normal operation
???Steady Amber: A PSU has been removed or there is a problem communicating with the PSU
???Blinking amber: PSU is in programming mode
6AC power status indicator (2)
7DC power fault indicator (2)
???Off: AC power is off, or the power is on but the module is not in a controller, or it may indicate a hardware fault
???Steady green: AC power is on
???Blinking green: AC power is on and the PSU is in standby mode
???Off: Normal operation
???Steady amber: A PSU has been removed, or there is a DC or other hardware fault, or there is a problem communicating with the PSU
???Blinking amber: PSU is in programming mode
SCv2000/SCv2020 Storage Controller Features and Indicators
The SCv2000/SCv2020 includes up to two storage controllers in two interface slots. The storage controllers support Fibre Channel, iSCSI, or SAS
SCv2000/SCv2020 Storage Controller with Fibre Channel
Features and indicators on a storage controller with Fibre Channel
Figure 8. Storage Controller with Four 8 Gb Fibre Channel
Figure 9. Storage Controller with Two 16 Gb Fibre Channel
???Fast blinking green (on 0.5 sec. / off 0.5 sec.): Battery is charging
???Steady green: Battery is ready
???Blinking amber: Correctable fault detected
???Steady amber: Uncorrectable fault detected; replace battery
7Recessed power off button
8Storage controller module fault
Powers down the storage controller if held for more than five seconds
???Off: No faults
???Steady amber: Firmware has detected an error
???Blinking amber:Storage controller is performing POST
???Blinking blue (for 15 sec.): Identification is enabled
???Blinking blue (continuously): Storage controller shut down to the Advanced Configuration and Power Interface (ACPI) S5 state
11USB port
12Diagnostic LEDs (8)
13Serial port (3.5 mm mini jack)
Not for customer use on SCv2000/SCv2020 Storage Systems.
?????? Green LEDs
??? Green LEDs
Not for customer use.
14Four or two Fibre Channel ports with three LEDs per port
15
16
?????? All off: No power
???All on: Booting up
???Blinking amber: 2 Gbps activity
???Blinking green: 4 Gbps activity
???Blinking yellow: 8 Gbps activity
???Blinking amber and yellow: Beacon
???All blinking (simultaneous): Firmware initialized
???All blinking (alternating): Firmware fault
SCv2000/SCv2020 Storage Controller with iSCSI
Features and indicators on a storage controller with iSCSI
Figure 10. SCv2000/SCv2020 Storage Controller with Four 1 GbE iSCSI
Figure 11. SCv2000/SCv2020 Storage Controller with Two 10 GbE iSCSI
???Fast blinking green (on 0.5 sec. / off 0.5 sec.): Battery is charging
???Steady green: Battery is ready
???Blinking amber: Correctable fault detected
???Steady amber: Uncorrectable fault detected; replace battery
???Blinking blue (continuously): Storage controller shut down to the Advanced Configuration and Power Interface (ACPI) S5 state
SCv2000/SCv2020 Storage Controller with SAS
Features and indicators on a storage controller with SAS
Figure 12. SCv2000/SCv2020 Storage Controller with Four 12 Gb SAS
???Fast blinking green (on 0.5 sec. / off 0.5 sec.): Battery is charging
???Steady green: Battery is ready
???Blinking amber: Correctable fault detected
???Steady amber: Uncorrectable fault detected; replace battery
7Recessed power off button
8Storage controller module fault
Powers down the storage controller if held for more than five seconds
???Off: No faults
???Steady amber: Firmware has detected an error
???Blinking amber:Storage controller is performing POST
9Recessed reset button
10Identification LED
11USB port
12Diagnostic LEDs (8)
13Serial port (3.5 mm mini jack)
14Four
15
16
Reboots the storage controller forcing it to restart at the POST process
??? Off: Identification disabled
???Blinking blue (for 15 sec.): Identification is enabled
???Blinking blue (continuously): Storage controller shut down to the Advanced Configuration and Power Interface (ACPI) S5 state
Not for customer use on SCv2000/SCv2020 Storage Systems.
?????? Green LEDs
??? Green LEDs
Not for customer use.
???
NOTE:
The
SCv2000/SCv2020 Drives
Dell Enterprise hard disk drives (HDDs) and Enterprise
The drives in an SCv2000 storage system are installed horizontally. The drives in an SCv2020 storage system are installed vertically. The indicators on the drives provide status and activity information.
Figure 13. SCv2000/SCv2020 Drive Indicators
??? Blinking amber (on 2 sec. / off 1 sec.): Drive failed
??? Steady amber: Drive is safe to remove
SCv2000/SCv2020 Storage System Drive Numbering
In an SCv2000/SCv2020 storage system, the drives are numbered from left to right.
Dell Storage Client identifies drives as
???An SCv2000 holds up to 12 drives, which are numbered left to right in rows starting from 0 at the top- left drive.
Figure 14. SCv2000 Drive Numbering
???An SCv2020 holds up to 24 drives, which are numbered left to right starting from 0.
Figure 15. SCv2020 Drive Numbering
SC100/SC120 Expansion Enclosure Overview
The SC100 is a 2U expansion enclosure that supports up to 12 3.5???inch hard drives installed in a four??? column,
The SC100/SC120 expansion enclosure ships with two redundant power supply/cooling fan modules and two redundant enclosure management modules (EMMs).
SC100/SC120 Expansion Enclosure Front Panel Features and Indicators
The SC100/SC120 front panel shows the expansion enclosure status and power supply status.
Figure 16. SC100
Figure 17. SC120
???Off: Both power supplies are off.
???On steady green: At least one power supply is providing power to the expansion enclosure
SC100/SC120 Expansion Enclosure Back Panel Features and Indicators
The SC100/SC120 back panel provides controls to power up and reset the expansion enclosure, indicators to show the expansion enclosure status, and connections for
Figure 18. SC100/SC120 Back Panel View
???Off: Power switch is off, the power supply is not connected to AC power, or there is a fault condition
SC100/SC120 Expansion Enclosure EMM Features and Indicators
The SC100/SC120 includes two Enclosure Management Modules (EMMs) in two interface slots.
Figure 19. SC100/SC120 EMM Features and Indicators
??? Off: Expansion enclosure is not connected
5SAS port B (out)
6Port B link status
Connects to a storage controller or to other SC100/SC120 expansion enclosures. SAS ports A and B can be used for either input or output. However for cabling consistency, use port B as an output port.
???Green: All the links to the port are connected
???Amber: One or more links are not connected
???Off: Expansion enclosure is not connected
7EMM status indicator
???On steady green: Normal operation
???Amber: Expansion enclosure did not boot or is not properly configured
???Blinking green: Automatic update in process
???Blinking amber (two times per sequence): Expansion enclosure is unable to communicate with other expansion enclosures
???Blinking amber (four times per sequence): Firmware update failed
???Blinking amber (five times per sequence): Firmware versions are different between the two EMMs
SC100/SC120 Expansion Enclosure Drives
Dell Enterprise hard disk drives (HDDs) and Enterprise
The drives in an SC100 expansion enclosure are installed horizontally. The drives in an SC120 expansion enclosure are installed vertically. The indicators on the drives provide status and activity information.
Figure 20. SC100/SC120 Drive Indicators
??? Off: No power to the drive
SC100/SC120 Expansion Enclosure Drive Numbering
In an SC100/SC120 expansion enclosure, the drives are numbered from left to right starting from 0. Dell Storage Client identifies drives as
???An SC100 holds up to 12 drives, which are numbered in rows starting from 0 at the
Figure 21. SC100 Drive Numbering
???An SC120 holds up to 24 drives, which are numbered left to right starting from 0.
Figure 22. SC120 Drive Numbering
2
Install the Storage Center Hardware
Prepare for the installation, mount the equipment in a rack, and install the disks.
Unpack and Inventory the Storage Center Equipment
Unpack the storage system and identify the items in your shipment.
Figure 23. SCv2000/SCv2020 Storage System Components
Prepare the Installation Environment
Make sure that the environment is ready for Storage Center installation.
???Rack Space: There must be sufficient space in the rack to accommodate the storage system chassis, expansion enclosures, and switches.
???Power: Power must be available in the rack, and the power delivery system must meet the requirements of the Storage Center.
???Connectivity: The rack must be wired for connectivity to the management network and any networks that carry
Safety Precautions
Always follow these safety precautions to avoid injury and damage to Storage Center equipment.
If equipment described in the document is used in a manner not specified by Dell, the protection provided by the equipment may be impaired. For your safety and protection, observe the rules described in the following sections.
NOTE: See the safety and regulatory information that shipped with each Storage Center component. Warranty information may be included within this document or as a separate document.
Installation Safety Precautions
Follow these safety precautions:
???Dell recommends that only individuals with
???Make sure the storage system is fully grounded at all times to prevent damage from electrostatic discharge.
???When handling the storage system hardware, you should use an electrostatic wrist guard (not included) or a similar form of protection.
The storage system chassis MUST be mounted in a rack; the following safety requirements must be considered when doing so:
???The rack construction must be capable of supporting the total weight of the installed chassis and the design should incorporate stabilizing features suitable to prevent the rack tipping or being pushed over during installation or in normal use.
???To avoid danger of the rack toppling over, do not slide more than one chassis out of the rack at a time.
???The rack design should take into consideration the maximum operating ambient temperature for the unit, which is 57??C.
Electrical Safety Precautions
Always follow electrical safety precautions to avoid injury and damage to Storage Center equipment.
WARNING: Disconnect power from the storage system when removing or installing components that are not
???Provide a suitable power source with electrical overload protection. All Storage Center components must be grounded before applying power. Make sure that there is a safe electrical earth connection to power supply cords. Check the grounding before applying power.
???The plugs on the power supply cords are used as the main disconnect device. Make sure that the socket outlets are located near the equipment and are easily accessible.
???Know the locations of the equipment power switches and the room's emergency
???Do not work alone when working with
???Use rubber mats specifically designed as electrical insulators.
???Do not remove covers from the power supply unit. Disconnect the power connection before removing a power supply from the storage system.
???Do not remove a faulty power supply unless you have a replacement model of the correct type ready for insertion. A faulty power supply must be replaced with a fully operational module power supply within 24 hours.
???Unplug the storage system chassis before you move it or if you think it has become damaged in any way. When powered by multiple AC sources, disconnect all supply power for complete isolation.
Electrostatic Discharge Precautions
Always follow electrostatic discharge (ESD) precautions to avoid injury and damage to Storage Center equipment.
Electrostatic discharge (ESD) is generated by two objects with different electrical charges coming into contact with each other. The resulting electrical discharge can damage electronic components and printed circuit boards. Follow these guidelines to protect your equipment from ESD:
???Dell recommends that you always use a static mat and static strap while working on components in the interior of the storage system chassis.
???Observe all conventional ESD precautions when handling
???Use a suitable ESD wrist or ankle strap.
???Avoid contact with backplane components and module connectors.
???Keep all components and printed circuit boards (PCBs) in their antistatic bags until ready for use.
General Safety Precautions
Always follow general safety precautions to avoid injury and damage to Storage Center equipment.
???Keep the area around the storage system chassis clean and free of clutter.
???Place any system components that have been removed away from the storage system chassis or on a table so that they are not in the way of foot traffic.
???While working on the storage system chassis, do not wear loose clothing such as neckties and unbuttoned shirt sleeves, which can come into contact with electrical circuits or be pulled into a cooling fan.
???Remove any jewelry or metal objects from your body because they are excellent metal conductors that can create short circuits and harm you if they come into contact with printed circuit boards or areas where power is present.
???Do not lift a storage system chassis by the handles of the power supply units (PSUs). They are not designed to hold the weight of the entire chassis, and the chassis cover may become bent.
???Before moving a storage system chassis, remove the PSUs to minimize weight.
???Do not remove drives until you are ready to replace them.
NOTE: To ensure proper storage system cooling, hard drive blanks must be installed in any hard drive slot that is not occupied.
Install the Storage System in a Rack
Install the storage system and other Storage Center system components in a rack.
About this task
Mount the storage system and expansion enclosures in a manner that allows for expansion in the rack and prevents the rack from becoming top???heavy.
Steps
1.Secure the rails that are
a.Lift the locking tab on the rail.
b.Push the rail towards the back of the chassis until it locks in place.
2.Determine where to mount the storage system and mark the location at the front and rear of the rack.
NOTE: The storage system and expansion enclosures each require 2U of rack space for installation.
3.Position a rail at the marked location and extend the rail to fit the rack.
4.Insert the two rail pins into the pin holes.
Figure 24. Hole Locations in Rack
3.Pin hole
5.Insert a screw into the rack mounting screw hole and tighten the screw to secure the rail to the rack.
6.Repeat the previous steps for the second rail.
7.Slide the storage system chassis onto the rails.
Figure 25. Mount the SCv2000/SCv2020 Storage System Chassis
8.Secure the storage system chassis to the rack using the mounting screws within each chassis ear.
a.Lift the latch on each chassis ear to access the screws.
b.Tighten the screws to secure the chassis into the rack.
c.Close the latch on each chassis ear.
9.If the Storage Center system includes expansion enclosures, mount the expansion enclosures in the rack. See the instructions included with the expansion enclosure for detailed steps.
3
Front???end connections can be made using Fibre Channel, iSCSI, or SAS interfaces. Dell recommends connecting the storage system to host servers using the most redundant option available.
Types of Redundancy for
Depending on how Storage Center is cabled and configured, the following types of redundancy are available.
Table 1. Redundancy and Failover Behavior
Port Redundancy
To allow for port redundancy, two
Fault domains group
If a port becomes unavailable because it is disconnected or there is a hardware failure, the port moves over to another port in the same fault domain.
Storage Controller Redundancy
To allow for storage controller redundancy, a
If a storage controller becomes unavailable, the
Multipath IO
MPIO allows a server to use multiple paths for IO if they are available.
MPIO software offers redundancy at the path level. MPIO typically operates in a
NOTE: MPIO is
MPIO Behavior
The server must have at least two FC, iSCSI, or SAS ports to use MPIO.
When MPIO is configured, a server can send IO to multiple ports on the same storage controller.
MPIO Configuration Instructions for Host Servers
To use MPIO, configure MPIO on the host server.
If a Dell Storage Client wizard is used to configure host server access to Storage Center, the Dell Storage Client attempts to automatically configure MPIO with best practices.
NOTE: Compare the host server settings applied by the Dell Storage Client wizard against the latest Dell Storage Center Best Practices document located on the Dell TechCenter (http:// en.community.dell.com/techcenter/storage/).
Table 2. MPIO Configuration Documents
VMware vSphere 5.x Dell Compellent Storage Center Best Practices with vSphere 5.x
Windows Server 2008, Dell Compellent Storage Center Microsoft Multipath IO (MPIO) Best Practices
2008 R2, 2012, and 2012 Guide
R2
To manually configure MPIO on a host server, see the Dell Best Practices document that corresponds to the server operating system. Depending on the operating system, you may need to install MPIO software or configure server options.
Cabling
An SCv2000/SCv2020 storage system with Fibre Channel or iSCSI
???A storage system with Fibre Channel
???A storage system with iSCSI
Connecting to Fibre Channel Host Servers
Choose the Fibre Channel connectivity option that best suits the front???end redundancy requirements and network infrastructure.
Preparing Host Servers
Install the Fibre Channel host bus adapters (HBAs), install the drivers, and make sure that the latest supported firmware is installed.
About this task
NOTE: Refer to the Dell Storage Compatibility Matrix for a list of supported Fibre Channel HBAs.
Steps
1.Install Fibre Channel HBAs in the host servers.
NOTE: Do not install Fibre Channel HBAs from different vendors in the same server.
2.Install supported drivers for the HBAs and make sure that the HBAs have the latest supported firmware
3.Use the Fibre Channel cabling diagrams to cable the host servers to the switches. Connecting host servers directly to the storage system without using Fibre Channel switches is not supported.
Two Fibre Channel Fabrics with Dual 16 Gb
Use two Fibre Channel (FC) fabrics to prevent an unavailable port, switch, or storage controller from causing a loss of connectivity between host servers and a storage system with dual 16 Gb
About this task
In this configuration, there are two fault domains, two FC fabrics, and two FC switches. The storage controllers connect to each FC switch using one FC connection.
???If a physical port or FC switch becomes unavailable, the storage system is accessed from the switch in the other fault domain.
???If a storage controller becomes unavailable, the virtual ports on the offline storage controller move to the physical ports on the other storage controller.
Steps
1.Connect each server to both FC fabrics.
2.Connect fault domain 1 (shown in orange) to fabric 1.
???Storage controller 1: port 1 to FC switch 1
???Storage controller 2: port 1 to FC switch 1
3.Connect fault domain 2 (shown in blue) to fabric 2.
???Storage controller 1: port 2 to FC switch 2
???Storage controller 2: port 2 to FC switch 2
Example
Figure 26. Storage System with Dual 16 Gb Storage Controllers and Two FC Switches
7.Storage controller 2
Next steps
Install or enable MPIO on the host servers.
NOTE: After the Storage Center configuration is complete, run the host access wizard to configure host server access and apply MPIO best practices. For the latest best practices, see the Dell Storage Center Best Practices document located on the Dell TechCenter (http://en.community.dell.com/ techcenter/storage/).
Two Fibre Channel Fabrics with Dual 8 Gb
Use two Fibre Channel (FC) fabrics to prevent an unavailable port, switch, or storage controller from causing a loss of connectivity between host servers and a storage system with dual 8 Gb
About this task
In this configuration, there are two fault domains, two FC fabrics, and two FC switches. The storage controllers connect to each FC switch using two FC connections.
???If a physical port becomes unavailable, the virtual port moves to another physical port in the same fault domain on the same storage controller.
???If an FC switch becomes unavailable, the storage system is accessed from the switch in the other fault domain.
???If a storage controller becomes unavailable, the virtual ports on the offline storage controller move to the physical ports on the other storage controller.
Steps
1.Connect each server to both FC fabrics.
2.Connect fault domain 1 (shown in orange) to fabric 1.
???Storage controller 1: port 1 to FC switch 1
???Storage controller 1: port 3 to FC switch 1
???Storage controller 2: port 1 to FC switch 1
???Storage controller 2: port 3 to FC switch 1
3.Connect fault domain 2 (shown in blue) to fabric 2.
???Storage controller 1: port 2 to FC switch 2
???Storage controller 1: port 4 to FC switch 2
???Storage controller 2: port 2 to FC switch 2
???Storage controller 2: port 4 to FC switch 2
Example
Figure 27. Storage System with Dual 8 Gb Storage Controllers and Two FC Switches
7.Storage controller 2
Next steps
Install or enable MPIO on the host servers.
NOTE: After the Storage Center configuration is complete, run the host access wizard to configure host server access and apply MPIO best practices. For the latest best practices, see the Dell Storage Center Best Practices document located on the Dell TechCenter (http://en.community.dell.com/ techcenter/storage/).
One Fibre Channel Fabric with Dual 16 Gb
Use one Fibre Channel (FC) fabric to prevent an unavailable port or storage controller from causing a loss of connectivity between the host servers and a storage system with dual 16 Gb
About this task
In this configuration, there are two fault domains, one fabric, and one FC switch. Each storage controller connects to the FC switch using two FC connections.
???If a physical port becomes unavailable, the storage system is accessed from another port on the FC switch.
???If a storage controller becomes unavailable, the virtual ports on the offline storage controller move to physical ports on the other storage controller.
NOTE: This configuration is vulnerable to switch unavailability, which results in a loss of connectivity between the host servers and storage system.
Steps
1.Connect each server to the FC fabric.
2.Connect fault domain 1 (shown in orange) to the fabric.
???Storage controller 1: port 1 to the FC switch
???Storage controller 2: port 1 to the FC switch
3.Connect fault domain 2 (shown in blue) to the fabric.
???Storage controller 1: port 2 to the FC switch
???Storage controller 2: port 2 to the FC switch
Example
Figure 28. Storage System with Dual 16 Gb Storage Controllers and One FC Switch
Next steps
Install or enable MPIO on the host servers.
NOTE: After the Storage Center configuration is complete, run the host access wizard to configure host server access and apply MPIO best practices. For the latest best practices, see the Dell Storage Center Best Practices document located on the Dell TechCenter (http://en.community.dell.com/ techcenter/storage/).
One Fibre Channel Fabric with Dual 8 Gb
Use one Fibre Channel (FC) fabric to prevent an unavailable port or storage controller from causing a loss of connectivity between the host servers a storage system with dual 8 Gb
About this task
In this configuration, there are two fault domains, one fabric, and one FC switch. Each storage controller connects to the FC switch using four FC connections.
???If a physical port becomes unavailable, the virtual port moves to another physical port in the same fault domain on the same storage controller.
???If a storage controller becomes unavailable, the virtual ports on the offline storage controller move to the physical ports on the other storage controller.
NOTE: This configuration is vulnerable to switch unavailability, which results in a loss of connectivity between the host servers and storage system.
Steps
1.Connect each server to the FC fabric.
2.Connect fault domain 1 (shown in orange) to the fabric.
???Storage controller 1: port 1 to the FC switch
???Storage controller 1: port 3 to the FC switch
???Storage controller 2: port 1 to the FC switch
???Storage controller 2: port 3 to the FC switch
3.Connect fault domain 2 (shown in blue) to the fabric.
???Storage controller 1: port 2 to the FC switch
???Storage controller 1: port 4 to the FC switch
???Storage controller 2: port 2 to the FC switch
???Storage controller 2: port 4 to the FC switch
Example
Figure 29. Storage System with Dual 8 Gb Storage Controllers and One FC Switch
Next steps
Install or enable MPIO on the host servers.
NOTE: After the Storage Center configuration is complete, run the host access wizard to configure host server access and apply MPIO best practices. For the latest best practices, see the Dell Storage Center Best Practices document located on the Dell TechCenter (http://en.community.dell.com/ techcenter/storage/).
Two Fibre Channel Fabrics with a Single 16 Gb
Use two Fibre Channel (FC) fabrics to prevent an unavailable port or switch from causing a loss of connectivity between the host servers and a storage system with a single 16 Gb
About this task
In this configuration, there are two fault domains, two FC fabrics, and two FC switches. The storage controller connects to each FC switch using one FC connection.
If a physical port or FC switch becomes unavailable, the storage system is accessed from the switch in the other fault domain.
NOTE: This configuration is vulnerable to storage controller unavailability, which results in a loss of connectivity between the host servers and storage system.
Steps
1.Connect each server to the FC fabric.
2.Connect fault domain 1 (shown in orange) to the fabric 1.
Storage controller: port 1 to FC switch 1.
3.Connect fault domain 2 (shown in blue) to the fabric 2. Storage controller: port 2 to FC switch 2.
Example
Figure 30. Storage System a Single 16 Gb Storage Controller and Two FC Switches
Next steps
Install or enable MPIO on the host servers.
NOTE: After the Storage Center configuration is complete, run the host access wizard to configure host server access and apply MPIO best practices. For the latest best practices, see the Dell Storage Center Best Practices document located on the Dell TechCenter (http://en.community.dell.com/ techcenter/storage/).
Two Fibre Channel Fabrics with a Single 8 Gb
Use two Fibre Channel (FC) fabrics to prevent an unavailable port or switch from causing a loss of connectivity between the host servers and a storage system with a single 8 Gb
About this task
In this configuration, there are two fault domains, two FC fabrics, and two FC switches. The storage controller connects to each FC switch using two FC connections.
???If a physical port becomes unavailable, the virtual port moves to another physical port in the same fault domain on the storage controller.
???If an FC switch becomes unavailable, the storage system is accessed from the switch in the other fault domain.
NOTE: This configuration is vulnerable to storage controller unavailability, which results in a loss of connectivity between the host servers and storage system.
Steps
1.Connect each server to both FC fabrics.
2.Connect fault domain 1 (shown in orange) to fabric 1.
???Storage controller 1: port 1 ??? FC switch 1
???Storage controller 1: port 3 ??? FC switch 1
3.Connect fault domain 2 (shown in blue) to fabric 2.
???Storage controller 1: port 2 ??? FC switch 2
???Storage controller 1: port 4 ??? FC switch 2
Example
Figure 31. Storage System a Single 8 Gb Storage Controller and Two FC Switches
Next steps
Install or enable MPIO on the host servers.
NOTE: After the Storage Center configuration is complete, run the host access wizard to configure host server access and apply MPIO best practices. For the latest best practices, see the Dell Storage Center Best Practices document located on the Dell TechCenter (http://en.community.dell.com/ techcenter/storage/).
Using SFP+ Transceiver Modules
An SCv2000/SCv2020 storage system with 16 Gb Fibre Channel storage controllers comes with short range
Figure 32. SFP+ Transceiver Module with a Bail Clasp Latch
The SFP+ transceiver modules are installed into the ports of the SCv2000/SCv2020 storage controller.
Guidelines for Using SFP+ Transceiver Modules
The SCv2000/SCv2020 storage system supports the use of SFP+ transceiver modules for 16 Gb FC connectivity.
Before installing SFP+ transceiver modules and
CAUTION: When handling
???Use only Dell supported SFP+ transceiver modules with the SCv2000/SCv2020. Other generic SFP+ transceiver modules are not supported and may not work with the SCv2000/SCv2020.
???The SFP+ transceiver module housing has an integral guide key that is designed to prevent you from inserting the transceiver module incorrectly.
???Use minimal pressure when inserting an SFP+ transceiver module into an FC port. Forcing the SFP+ transceiver module into a port may damage the transceiver module or the port.
???The SFP+ transceiver module must be installed into a port before you connect the
???The
Install an SFP+ Transceiver Module
Complete the following steps to install an SFP+ transceiver module in a 16 Gb FC storage controller.
About this task
Read the following cautions and information before installing an SFP+ transceiver module.
WARNING: To reduce the risk of injury from laser radiation or damage to the equipment, observe the following precautions:
???Do not open any panels, operate controls, make adjustments, or perform procedures to a laser device other than those specified herein.
???Do not stare into the laser beam.
CAUTION: Transceiver modules can be damaged by electrostatic discharge (ESD). To prevent ESD damage to the transceiver module, take the following precautions:
???Wear an antistatic discharge strap while handling transceiver modules.
???Place transceiver modules in antistatic packing material when transporting or storing them.
Steps
1.Position the transceiver module so that the key is oriented correctly to the port in the storage controller.
Figure 33. Install the SFP+ Transceiver Module
2.Insert the transceiver module into the port until it is firmly seated and the latching mechanism clicks.
The transceiver modules are keyed so that they can only be inserted with the correct orientation. If a transceiver module does not slide in easily, ensure that it is correctly oriented.
CAUTION: To reduce the risk of damage to the equipment, do not use excessive force when inserting the transceiver module.
3.Position
CAUTION: Touching the end of a
4.Insert the
5.Insert the other end of the
Remove an SFP+ Transceiver Module
Complete the following steps to remove an SFP+ transceiver module from a 16 Gb FC storage controller.
Prerequisites
Use failover testing to make sure that the connection between host servers and Storage Center remains up if the port is disconnected.
About this task
Read the following cautions and information before beginning removal or replacement procedures.
WARNING: To reduce the risk of injury from laser radiation or damage to the equipment, observe the following precautions:
???Do not open any panels, operate controls, make adjustments, or perform procedures to a laser device other than those specified herein.
???Do not stare into the laser beam.
CAUTION: Transceiver modules can be damaged by electrostatic discharge (ESD). To prevent ESD damage to the transceiver module, take the following precautions:
???Wear an antistatic discharge strap while handling modules.
???Place modules in antistatic packing material when transporting or storing them.
Steps
1.Remove the
a.Make certain the
b.Press the release clip on the bottom of the cable connector to remove the
CAUTION: Touching the end of a
2.Open the transceiver module latching mechanism.
3.Grasp the bail clasp latch on the transceiver module and pull the latch out and down to eject the transceiver module from the socket.
4.Slide the transceiver module out of the port.
Figure 34. Remove the SFP+ Transceiver Module
Fibre Channel Zoning
When using Fibre Channel for
Zoning can be applied to either the ports on switches or to the World Wide Names (WWNs) of the end devices.
Dell recommends creating zones using a single initiator host port and multiple Storage Center ports.
WWN Zoning Guidelines
When WWN zoning is configured, a device may reside on any port or change physical ports and still be visible because the switch is seeking a WWN.
List of guidelines for WWN zoning.
???Include all Storage Center virtual WWNs in a single zone.
???Include all Storage Center physical WWNs in a single zone.
???For each host server HBA port, create a zone that includes the single HBA WWN and multiple Storage Center virtual WWNs on the same switch.
???For Fibre Channel replication:
???Include all Storage Center physical WWNs from Storage Center system A and Storage Center system B in a single zone.
???Include all Storage Center physical WWNs of Storage Center system A and the virtual WWNs of Storage Center system B on the particular fabric.
???Include all Storage Center physical WWNs of Storage Center system B and the virtual WWNs of Storage Center system A on the particular fabric.
NOTE: Some ports may not be used or dedicated for replication, however ports that are used must be in these zones.
Port Zoning Guidelines
When port zoning is configured, only specific switch ports are visible. If a storage device is moved to a different switch port that is not part of the zone, it is no longer visible to the other ports in the zone.
List of port zoning guidelines.
???Include all Storage Center
???For each host server port, create a zone that includes a single server HBA port and all Storage Center ports.
???Create server zones which contain all Storage Center
???For Fibre Channel replication, include all Storage Center
Labeling the
Label the
Prerequisites
Locate the
About this task
Apply cable labels to both ends of each cable that connects a storage controller to a
Steps
1.Starting with the top edge of the label, attach the label to the cable near the connector.
Figure 35. Attach Label to Cable
2.Wrap the label around the cable until it fully encircles the cable. The bottom of each label is clear so that it does not obscure the text.
Figure 36. Wrap Label Around Cable
3.Apply a matching label to the other end of the cable.
Connecting to iSCSI Host Servers
Choose the iSCSI connectivity option that best suits the front???end redundancy requirements and network infrastructure.
Preparing Host Servers
Install the iSCSI host bus adapters (HBAs) or iSCSI network adapters, install the drivers, and make sure that the latest supported firmware is installed.
NOTE: Refer to the Dell Storage Compatibility Matrix for a list of supported iSCSI HBAs and network adapters.
???If the host server is a Windows or Linux host:
a. Install the iSCSI HBAs or network adapters dedicated for iSCSI traffic in the host servers.
NOTE: Do not install iSCSI HBAs or network adapters from different vendors in the same server.
b.Install supported drivers for the HBAs or network adapters and make sure that the HBAs or network adapter have the latest supported firmware
c.Use the host operating system to assign IP addresses for each iSCSI port. The IP addresses must match the subnets for each fault domain.
CAUTION: Correctly assign IP addresses to the HBAs or network adapters. Assigning IP addresses to the wrong ports can cause connectivity issues.
NOTE: If using jumbo frames, they must be enabled and configured on all devices in the data path, adapter ports, switches, and storage system.
d.Use the iSCSI cabling diagrams to cable the host servers to the switches. Connecting host servers directly to the storage system without using Ethernet switches is not supported.
???If the host server is a vSphere host:
a.Install the iSCSI HBAs or network adapters dedicated for iSCSI traffic in the host servers.
b.Install supported drivers for the HBAs or network adapters and make sure that the HBAs or network adapter have the latest supported firmware
c.If the host uses network adapters for iSCSI traffic, create a VMkernel port for each network adapter. (1 VMkernel per vSwitch)
d.Use the host operating system to assign IP addresses for each iSCSI port. The IP addresses must match the subnets for each fault domain..
CAUTION: Correctly assign IP addresses to the HBAs or network adapters. Assigning IP addresses to the wrong ports can cause connectivity issues.
NOTE: If using jumbo frames, they must be enabled and configured on all devices in the data path, adapter ports, switches, and storage system.
e.If the host uses network adapters for iSCSI traffic, add the VMkernel ports to the iSCSI software initiator.
f.Use the iSCSI cabling diagrams to cable the host servers to the switches. Connecting host servers directly to the storage system without using Ethernet switches is not supported.
Two iSCSI Networks with Dual 10 GbE
Use two iSCSI networks to prevent an unavailable port, switch, or storage controller from causing a loss of connectivity between the host servers and a storage system with dual 10 GbE
About this task
In this configuration, there are two fault domains, two iSCSI networks, and two Ethernet switches. The storage controllers connect to each Ethernet switch using one iSCSI connection.
???If a physical port or Ethernet switch becomes unavailable, the storage system is accessed from the switch in the other fault domain.
???If a storage controller becomes unavailable, the virtual ports on the offline storage controller move to the physical ports on the other storage controller.
Steps
1.Connect each server to both iSCSI networks.
2.Connect fault domain 1 (shown in orange) to iSCSI network 1.
??? Storage controller 1: port 1 to Ethernet switch 1
???Storage controller 2: port 1 to Ethernet switch 1
3.Connect fault domain 2 (shown in blue) to iSCSI network 2.
???Storage controller 1: port 2 to Ethernet switch 2
???Storage controller 2: port 2 to Ethernet switch 2
Example
Figure 37. Storage System with Dual 10 GbE Storage Controllers and Two Ethernet Switches
1.Server 1
3.Ethernet switch 1 (Fault domain 1)
5.Storage system
7.Storage controller 2
Next steps
Install or enable MPIO on the host servers.
2.Server 2
4.Ethernet switch 2 (Fault domain 2)
6.Storage controller 1
NOTE: After the Storage Center configuration is complete, run the host access wizard to configure host server access and apply MPIO best practices. For the latest best practices, see the Dell Storage Center Best Practices document located on the Dell TechCenter (http://en.community.dell.com/ techcenter/storage/).
Two iSCSI Networks with Dual 1 GbE
Use two iSCSI networks to prevent an unavailable port, switch, or storage controller from causing a loss of connectivity between the host servers and a storage system with dual 1 GbE
About this task
In this configuration, there are two fault domains, two iSCSI networks, and two Ethernet switches. The storage controllers connect to each Ethernet switch using two iSCSI connections.
???If a physical port becomes unavailable, the virtual port moves to another physical port in the same fault domain on the same storage controller.
???If an Ethernet switch becomes unavailable, the storage system is accessed from the switch in the other fault domain.
???If a storage controller becomes unavailable, the virtual ports on the offline storage controller move to physical ports on the other storage controller.
Steps
1.Connect each server to both iSCSI networks.
2.Connect fault domain 1 (shown in orange) to iSCSI network 1.
???Storage controller 1: port 1 to Ethernet switch 1
???Storage controller 2: port 1 to Ethernet switch 1
???Storage controller 1: port 3 to Ethernet switch 1
???Storage controller 2: port 3 to Ethernet switch 1
3.Connect fault domain 2 (shown in blue) to iSCSI network 2.
???Storage controller 1: port 2 to Ethernet switch 2
???Storage controller 2: port 2 to Ethernet switch 2
???Storage controller 1: port 4 to Ethernet switch 2
???Storage controller 2: port 4 to Ethernet switch 2
Example
Figure 38. Storage System with Dual 1 GbE Storage Controllers and Two Ethernet Switches
1.Server 1
3.Ethernet switch 1 (Fault domain 1)
5.Storage system
7.Storage controller 2
Next steps
Install or enable MPIO on the host servers.
2.Server 2
4.Ethernet switch 2 (Fault domain 2)
6.Storage controller 1
NOTE: After the Storage Center configuration is complete, run the host access wizard to configure host server access and apply MPIO best practices. For the latest best practices, see the Dell Storage Center Best Practices document located on the Dell TechCenter (http://en.community.dell.com/ techcenter/storage/).
One iSCSI Network with Dual 10 GbE
Use one iSCSI network to prevent an unavailable port or storage controller from causing a loss of connectivity between the host servers and a storage system with dual 10 GbE
About this task
In this configuration, there are two fault domains, one iSCSI network, and one Ethernet switch. Each storage controller connects to the Ethernet switch using two iSCSI connections.
???If a physical port becomes unavailable, the storage system is accessed from another port on the Ethernet switch.
???If a storage controller becomes unavailable, the virtual ports on the offline storage controller move to the physical ports on the other storage controller.
NOTE: This configuration is vulnerable to switch unavailability, which results in a loss of connectivity between the host servers and storage system.
Steps
1.Connect each server to the iSCSI network.
2.Connect fault domain 1 (shown in orange) to the iSCSI network.
???Storage controller 1: port 1 to the Ethernet switch
???Storage controller 2: port 1 to the Ethernet switch
3.Connect fault domain 2 (shown in blue) to the iSCSI network.
???Storage controller 1: port 2 to the Ethernet switch
???Storage controller 2: port 2 to the Ethernet switch
Example
Figure 39. Storage System with Dual 10 GbE Storage Controllers and One Ethernet Switch
Next steps
Install or enable MPIO on the host servers.
NOTE: After the Storage Center configuration is complete, run the host access wizard to configure host server access and apply MPIO best practices. For the latest best practices, see the Dell Storage Center Best Practices document located on the Dell TechCenter (http://en.community.dell.com/ techcenter/storage/).
One iSCSI Network with Dual 1 GbE
Use one iSCSI network to prevent an unavailable port or storage controller from causing a loss of connectivity between the host servers and a storage system with dual 1 GbE
About this task
In this configuration, there are two fault domains, one iSCSI network, and one Ethernet switch. Each storage controller connects to the Ethernet switch using four iSCSI connections.
???If a physical port becomes unavailable, the virtual port moves to another physical port in the same fault domain on the same storage controller.
???If a storage controller becomes unavailable, the virtual ports on the offline storage controller move to the physical ports on the other storage controller.
NOTE: This configuration is vulnerable to switch unavailability, which results in a loss of connectivity between the host servers and storage system.
Steps
1.Connect each server to the iSCSI network.
2.Connect fault domain 1 (shown in orange) to the iSCSI network.
???Storage controller 1: port 1 to the Ethernet switch
???Storage controller 1: port 3 to the Ethernet switch
???Storage controller 2: port 1 to the Ethernet switch
???Storage controller 2: port 3 to the Ethernet switch
3.Connect fault domain 2 (shown in blue) to the iSCSI network.
???Storage controller 1: port 2 to the Ethernet switch
???Storage controller 1: port 4 to the Ethernet switch
???Storage controller 2: port 2 to the Ethernet switch
???Storage controller 2: port 4 to the Ethernet switch
Example
Figure 40. Storage System with Dual 1 GbE Storage Controllers and One Ethernet Switch
Next steps
Install or enable MPIO on the host servers.
NOTE: After the Storage Center configuration is complete, run the host access wizard to configure host server access and apply MPIO best practices. For the latest best practices, see the Dell Storage Center Best Practices document located on the Dell TechCenter (http://en.community.dell.com/ techcenter/storage/).
Two iSCSI Networks with a Single 10 GbE
Use two iSCSI networks to prevent an unavailable port or switch from causing a loss of connectivity between the host servers and a storage system with a single 10 GbE
About this task
In this configuration, there are two fault domains, two iSCSI networks, and two Ethernet switches. The storage controller connects to the Ethernet switches using two iSCSI connections.
If a physical port or Ethernet switch becomes unavailable, the storage system is accessed from the switch in the other fault domain.
NOTE: This configuration is vulnerable to storage controller unavailability, which results in a loss of connectivity between the host servers and storage system.
Steps
1.Connect each server to the iSCSI network.
2.Connect the fault domain 1 (shown in orange) to iSCSI network 1.
Storage controller: port 1 to Ethernet switch 1
3.Connect the fault domain 2 (shown in orange) to iSCSI network 2. Storage controller: port 2 to Ethernet switch 2
Example
Figure 41. Storage System with One 10 GbE Storage Controller and Two Ethernet Switches
1.Server 1
3.Ethernet switch 1 (Fault domain 1)
5.Storage system
Next steps
Install or enable MPIO on the host servers.
2.Server 2
4.Ethernet switch 2 (Fault domain 2)
6.Storage controller
NOTE: After the Storage Center configuration is complete, run the host access wizard to configure host server access and apply MPIO best practices. For the latest best practices, see the Dell Storage Center Best Practices document located on the Dell TechCenter (http://en.community.dell.com/ techcenter/storage/).
Two iSCSI Networks with a Single 1 GbE
Use two iSCSI networks to prevent an unavailable port or switch from causing a loss of connectivity between the host servers and a storage system with a single 1 GbE
About this task
In this configuration, there are two fault domains, two iSCSI networks, and two Ethernet switches. The storage controller connects to each Ethernet switch using two iSCSI connections.
???If a physical port becomes unavailable, the virtual port moves to another physical port in the same fault domain on the storage controller.
???If an Ethernet switch becomes unavailable, the storage system is accessed from the switch in the other fault domain.
NOTE: This configuration is vulnerable to storage controller unavailability, which results in a loss of connectivity between the host servers and storage system.
Steps
1.Connect each server to both iSCSI networks.
2.Connect fault domain 1 (shown in orange) to iSCSI network 1.
???Storage controller 1: port 1 to Ethernet switch 1
???Storage controller 1: port 3 to Ethernet switch 1
3.Connect fault domain 2 (shown in blue) to iSCSI network 2.
???Storage controller 1: port 2 to Ethernet switch 2
???Storage controller 1: port 4 to Ethernet switch 2
Example
Figure 42. Storage System with One 1 GbE Storage Controller and Two Ethernet Switches
1.Server 1
3.Ethernet switch 1 (Fault domain 1)
5.Storage system
Next steps
Install or enable MPIO on the host servers.
2.Server 2
4.Ethernet switch 2 (Fault domain 2)
6.Storage controller
NOTE: After the Storage Center configuration is complete, run the host access wizard to configure host server access and apply MPIO best practices. For the latest best practices, see the Dell Storage Center Best Practices document located on the Dell TechCenter (http://en.community.dell.com/ techcenter/storage/).
Labeling the
Label the
Prerequisites
Locate the
About this task
Apply cable labels to both ends of each cable that connects a storage controller to a
Steps
1.Starting with the top edge of the label, attach the label to the cable near the connector.
Figure 43. Attach Label to Cable
2.Wrap the label around the cable until it fully encircles the cable. The bottom of each label is clear so that it does not obscure the text
Figure 44. Wrap Label Around Cable
3.Apply a matching label to the other end of the cable.
Cabling
An SCv2000/SCv2020 storage system with SAS
Preparing Host Servers
On each host server, install the SAS host bus adapters (HBAs), install the drivers, and make sure that the latest supported firmware is installed.
About this task
NOTE: Refer to the Dell Storage Compatibility Matrix for a list of supported SAS HBAs.
Steps
1.Install the SAS HBAs in the host servers.
NOTE: Do not install SAS HBAs from different vendors in the same server.
2.Install supported drivers for the HBAs and make sure that the HBAs have the latest supported firmware installed.
3.Use the SAS cabling diagram to cable the host servers directly to the storage system.
NOTE: If deploying vSphere hosts, configure only one host at a time.
SAS Virtual Port Mode
To provide redundancy in SAS virtual port mode, the
In SAS virtual port mode, a volume is active on only one storage controller, but it is visible to both storage controllers. Asymmetric Logical Unit Access (ALUA) controls the path that a server uses to access a volume.
If a storage controller becomes unavailable, the volume becomes active on the other storage controller. The state of the paths on the available storage controller are set to Active/Optimized and the state of the paths on the other storage controller are set to Standby. When the storage controller becomes available again and the ports are rebalanced, the volume moves back to its preferred storage controller and the ALUA states are updated.
If a SAS path becomes unavailable, the Active/Optimized volumes on that path become active on the other storage controller. The state of the failed path for those volumes is set to Standby and the state of the active path for those volumes is set to Active/Optimized.
NOTE: Failover in SAS virtual port mode occurs within a single fault domain. Therefore, a server must have both connections in the same fault domain. For example, if a server is connected to SAS port 2 on one storage controller, it must be connected to SAS port two on the other storage controller. If a server is not cabled correctly when a storage controller or SAS path becomes unavailable, access to the volume is lost.
Two Servers Connected to Dual 12 Gb
A storage system with four 12 Gb
About this task
In this configuration, there are four fault domains spread across both storage controllers. The storage controllers are connected to each host server using four SAS connections.
If a storage controller becomes unavailable, all of the standby paths on the other storage controller become active.
Steps
1.Connect fault domain 1 (shown in orange) to the host server 1.
a.Connect a SAS cable from storage controller 1: port 1 to host server 1.
b.Connect a SAS cable from storage controller 2: port 1 to host server 1.
2.Connect fault domain 2 (shown in blue) to the host server 1.
a.Connect a SAS cable from storage controller 1: port 2 to host server 1.
b.Connect a SAS cable from storage controller 2: port 2 to host server 1.
3.Connect fault domain 3 (shown in gray) to the host server 2.
a.Connect a SAS cable from storage controller 1: port 3 to host server 2.
b.Connect a SAS cable from storage controller 2: port 3 to host server 2.
4.Connect fault domain 4 (shown in red) to the host server 2.
a.Connect a SAS cable from storage controller 1: port 4 to host server 2.
b.Connect a SAS cable from storage controller 2: port 4 to host server 2.
Example
Figure 45. Storage System with Dual 12 Gb SAS Storage Controllers Connected to Two Host Servers
5.Storage controller 2
Next steps
Install or enable MPIO on the host servers.
NOTE: After the Storage Center configuration is complete, run the host access wizard to configure host server access and apply MPIO best practices. For the latest best practices, see the Dell Storage Center Best Practices document located on the Dell TechCenter (http://en.community.dell.com/ techcenter/storage/).
Four Servers Connected to Dual 12 Gb
A storage system with four 12 Gb
About this task
In this configuration, four fault domains are spread across both storage controllers. The storage controllers are connected to each host server using two SAS connections.
If a storage controller becomes unavailable, all of the standby paths on the other storage controller become active.
Steps
1.Connect fault domain 1 (shown in orange) to the host server 1.
a.Connect a SAS cable from storage controller 1: port 1 to host server 1.
b.Connect a SAS cable from storage controller 2: port 1 to host server 1.
2.Connect fault domain 2 (shown in blue) to the host server 2.
a.Connect a SAS cable from storage controller 1: port 2 to host server 2.
b.Connect a SAS cable from storage controller 2: port 2 to host server 2.
3.Connect fault domain 3 (shown in gray) to the host server 3.
a.Connect a SAS cable from storage controller 1: port 3 to host server 3.
b.Connect a SAS cable from storage controller 2: port 3 to host server 3.
4.Connect fault domain 4 (shown in red) to the host server 4.
a.Connect a SAS cable from storage controller 1: port 4 to host server 4.
b.Connect a SAS cable from storage controller 2: port 4 to host server 4.
Example
Figure 46. Storage System with Dual 12 Gb SAS Storage Controllers Connected to Four Host Servers
7.Storage controller 2
Next steps
Install or enable MPIO on the host servers.
NOTE: After the Storage Center configuration is complete, run the host access wizard to configure host server access and apply MPIO best practices. For the latest best practices, see the Dell Storage Center Best Practices document located on the Dell TechCenter (http://en.community.dell.com/ techcenter/storage/).
Two Servers Connected to a Single 12 Gb
A storage system with four 12 Gb
About this task
In this configuration, there are four fault domains and the storage controller is connected to each host server using two SAS connections.
NOTE: This configuration is vulnerable to storage controller unavailability, which results in a loss of connectivity between the host servers and storage system.
Steps
1.Connect fault domain 1 to the host server 1, by connecting a SAS cable from storage controller 1: port 1 to host server 1.
2.Connect fault domain 2 to the host server 1, by connecting a SAS cable from storage controller 1: port 2 to host server 1.
3.Connect fault domain 3 to the host server 2, by connecting a SAS cable from storage controller 1: port 3 to host server 2.
4.Connect fault domain 4 to the host server 2, by connecting a SAS cable from storage controller 1: port 4 to host server 2.
Example
Figure 47. Storage System with One 12 Gb SAS Storage Controller Connected to Two Host Servers
Next steps
Install or enable MPIO on the host servers.
NOTE: After the Storage Center configuration is complete, run the host access wizard to configure host server access and apply MPIO best practices. For the latest best practices, see the Dell Storage Center Best Practices document located on the Dell TechCenter (http://en.community.dell.com/ techcenter/storage/).
Labeling the
Label the
Prerequisites
Locate the
About this task
Apply cable labels to both ends of each cable that connects a storage controller to a
Steps
1.Starting with the top edge of the label, attach the label to the cable near the connector.
Figure 48. Attach Label to Cable
2.Wrap the label around the cable until it fully encircles the cable. The bottom of each label is clear so that it does not obscure the text.
Figure 49. Wrap Label Around Cable
3.Apply a matching label to the other end of the cable.
Cabling the Ethernet Management Port
To manage Storage Center, the Ethernet management (MGMT) port of each storage controller must be connected to an Ethernet switch that is part of the management network.
About this task
The management port provides access to the storage system through the Dell Storage Client software and is used to send emails, alerts, SNMP traps, and SupportAssist diagnostic data. The management port also provides access to the baseboard management controller (BMC) software.
NOTE: If the Flex Port license is installed, the management port becomes a shared iSCSI port. To use the management port as an iSCSI port, it must be cabled to a network switch dedicated to iSCSI traffic. Special considerations must be taken into account when sharing the management port.
Steps
1.Connect the Ethernet management port on storage controller 1 to the Ethernet switch.
2.Connect the Ethernet management port on storage controller 2 to the Ethernet switch.
Figure 50. Storage System Connected to a Management Network
Labeling the Ethernet Management Cables
Label the Ethernet management cables that connect each storage controller to an Ethernet switch.
Prerequisites
Locate the
About this task
Apply cable labels to both ends of each Ethernet management cable.
Steps
1.Starting with the top edge of the label, attach the label to the cable near the connector.
Figure 51. Attach Label to Cable
2.Wrap the label around the cable until it fully encircles the cable. The bottom of each label is clear so that it does not obscure the text.
Figure 52. Wrap Label Around Cable
3.Apply a matching label to the other end of the cable.
Cabling the Embedded Ports for iSCSI Replication
If the Storage Center is licensed for replication, the replication port can be connected to an Ethernet switch and used for iSCSI replication. If the Storage Center is licensed for replication and the Flex Port license is installed, the management port and replication port can be connected to an Ethernet switch and used for iSCSI replication.
Cabling the Replication Port for iSCSI Replication
If replication is licensed, the replication (REPL) port can be used to replicate data to another Storage Center.
About this task
Connect the replication port of each storage controller to an Ethernet switch through which the Storage Center can perform iSCSI replication.
Steps
1.Connect the replication port on storage controller 1 to Ethernet switch 2.
2.Connect the replication port on storage controller 2 to Ethernet switch 2.
NOTE: The management port on each storage controller is connected to an Ethernet switch on the management network.
5.Storage controller 2
3.To configure the fault domain and ports, click the Configure Embedded iSCSI Ports link on the
Configuration Complete page of the Discover and Configure Uninitialized SCv2000 Series Storage Centers wizard.
4.To configure replication, refer to the Dell Enterprise Manager Administrator???s Guide.
Related Links
Configure Embedded iSCSI Ports
Cabling the Management Port and Replication Port for iSCSI Replication
If replication is licensed and the Flex Port license is installed, both the management (MGMT) and replication (REPL) ports can be used to replicate data to another Storage Center.
About this task
Connect the management port and replication port on each storage controller to an Ethernet switch through which the Storage Center can perform replication.
Steps
1.Connect Flex Port Domain 1 (shown in orange) to the iSCSI network.
a.Connect the management port on storage controller 1 to the Ethernet switch.
b.Connect the management port on storage controller 2 to the Ethernet switch.
2.Connect iSCSI Embedded Domain 2 (shown in blue) to the iSCSI network.
a.Connect the replication port on storage controller 1 to the Ethernet switch.
b.Connect the replication port on storage controller 2 to the Ethernet switch.
Figure 54. Management and Replication Ports Connected to an iSCSI Network
3.To configure the fault domains and ports, click the Configure Embedded iSCSI Ports link on the
Configuration Complete page of the Discover and Configure Uninitialized SCv2000 Series Storage Centers wizard.
4.To configure replication, refer to the Dell Enterprise Manager Administrator???s Guide.
Related Links
Configure Embedded iSCSI Ports
Cabling the Embedded Ports for iSCSI Host Connectivity
If the Flex Port license is installed on the Storage Center, the management port and replication port can be connected to an Ethernet switch and used for iSCSI host connectivity.
Two iSCSI Networks with Dual Storage Controllers and Embedded Ethernet Ports
Use two iSCSI networks to prevent an unavailable port, switch, or storage controller from causing a loss of connectivity between the host servers and a storage system with dual storage controllers.
About this task
In this configuration, there are two fault domains, two iSCSI networks, and two Ethernet switches. The storage controllers connect to each Ethernet switch using one iSCSI connection.
???If a physical port or Ethernet switch becomes unavailable, the storage system is accessed from the switch in the other fault domain.
???If a storage controller becomes unavailable, the virtual ports on the offline storage controller move to the physical ports on the other storage controller.
Steps
1.Connect each server to both iSCSI networks.
2.Connect embedded fault domain 1 (shown in orange) to iSCSI network 1.
a.Connect the management port on storage controller 1 to Ethernet switch 1.
b.Connect the management port on storage controller 2 to Ethernet switch 1.
3.Connect embedded fault domain 2 (shown in blue) to iSCSI network 2.
a.Connect the replication port on storage controller 1 to Ethernet switch 2.
b.Connect the replication port on storage controller 2 to Ethernet switch 2.
Figure 55. Storage System with Dual Storage Controllers and Two Ethernet Switches
1.Server 1
3.Ethernet switch 1 (Fault domain 1)
5.Storage system
2.Server 2
4.Ethernet switch 2 (Fault domain 2)
6.Storage controller 1
7.Storage controller 2
4.To configure the fault domains and ports, click the Configure Embedded iSCSI Ports link on the
Configuration Complete page of the Discover and Configure Uninitialized SCv2000 Series Storage Centers wizard.
Next steps
Install or enable MPIO on the host servers.
NOTE: After the Storage Center configuration is complete, run the host access wizard to configure host server access and apply MPIO best practices. For the latest best practices, see the Dell Storage Center Best Practices documents located on the Dell TechCenter (http://en.community.dell.com/ techcenter/storage/).
Related Links
Configure Embedded iSCSI Ports
One iSCSI Network with Dual Storage Controllers and Embedded Ethernet Ports
Use one iSCSI network to prevent an unavailable port or storage controller from causing a loss of connectivity between the host servers and a storage system with dual storage controllers .
About this task
In this configuration, there are two fault domains, one iSCSI network, and one Ethernet switch. Each storage controller connects to the Ethernet switch using two iSCSI connections.
???If a physical port becomes unavailable, the storage system is accessed from another port on the Ethernet switch.
???If a storage controller becomes unavailable, the virtual ports on the offline storage controller move to the physical ports on the other storage controller.
NOTE: This configuration is vulnerable to switch unavailability, which results in a loss of connectivity between the host servers and storage system.
Steps
1.Connect each server to the iSCSI network.
2.Connect embedded fault domain 1 (shown in orange) to the iSCSI network.
a.Connect the management port on storage controller 1 to the Ethernet switch
b.Connect the management port on storage controller 2 to the Ethernet switch
3.Connect embedded fault domain 2 (shown in blue) to the iSCSI network.
a.Connect the replication port on storage controller 1 to the Ethernet switch
b.Connect the replication port on storage controller 2 to the Ethernet switch
Figure 56. Storage System with Dual Storage Controllers and One Ethernet Switch
4.To configure the fault domains and ports, click the Configure Embedded iSCSI Ports link on the
Configuration Complete page of the Discover and Configure Uninitialized SCv2000 Series Storage Centers wizard.
Next steps
Install or enable MPIO on the host servers.
NOTE: After the Storage Center configuration is complete, run the host access wizard to configure host server access and apply MPIO best practices. For the latest best practices, see the Dell Storage Center Best Practices documents located on the Dell TechCenter (http://en.community.dell.com/ techcenter/storage/).
Related Links
4
An SCv2000/SCv2020 storage system can be deployed with or without expansion enclosures.
???When an SCv2000/SCv2020 is deployed without expansion enclosures, the storage controllers must be interconnected using SAS cables. This connection enables SAS path redundancy between the storage controllers and the internal disks.
???When an SCv2000/SCv2020 is deployed with expansion enclosures, the expansion enclosures connect to the SAS ports on the storage controllers.
SC100/SC120 Expansion Enclosure Cabling Guidelines
You can connect multiple SC100/SC120 expansion enclosures to an SCv2000/SCv2020 by cabling the expansion enclosures in series.
The connection between a storage system and the expansion enclosures is referred to as a SAS chain. A SAS chain is made up of two paths, which are referred to as the A side and B side. Each side of the SAS chain starts at the initiator only SAS port on one storage controller and ends at the initiator/target SAS port the other storage controller.
SAS Redundancy
Use redundant SAS cabling to make sure that an unavailable IO port or storage controller does not cause a Storage Center outage.
If an IO port or storage controller becomes unavailable, the Storage Center IO moves to the redundant path.
SAS Port Types
There are two types of
Figure 57. SCv2000/SCv2020 SAS Ports
3.Initiator only ports (ports A)
5.Storage controller 2
4.Initiator/target ports (ports B)
When you deploy an SCv2000/SCv2020 without expansion enclosures, you must interconnect the storage controllers using SAS cables.
About this task
NOTE: The top storage controller is storage controller 1 and the bottom storage controller is storage controller 2.
Steps
1.Connect a SAS cable between storage controller 1: port A and storage controller 2: port B.
2.Connect a SAS cable between storage controller 1: port B and storage controller 2: port A.
Example
Figure 58. Interconnected Storage Controllers
3.Storage controller 2
This section shows common cabling between the SCv2000/SCv2020 and SC100/SC120 expansion enclosures. Locate the scenario that most closely matches the Storage Center that you are configuring and follow the instructions, modifying them as necessary.
The SCv2000/SCv2020 supports up to eight SC100 expansion enclosures, up to four SC120 expansion enclosures, or any combination of SC100/SC120 expansion enclosures as long as the total disk count does not exceed 168 disks.
SC100/SC120 expansion enclosures chains are cabled as follows.
???Side A (Orange): Expansion enclosures are connected from port B to port A, using the top EMMs.
???Side B (Orange): Expansion enclosures are connected from port A to port B, using the bottom EMMs.
SCv2000/SCv2020 and One SC100/SC120 Expansion Enclosure
This figure shows an SCv2000/SCv2020 cabled to one expansion enclosure forming a single chain.
Figure 59. SCv2000/SCv2020 and One SC100/SC120 Expansion Enclosure
2.Expansion enclosure: top EMM, port B to storage controller 2: port B.
SCv2000/SCv2020 and Two or More SC100/SC120 Expansion Enclosures
This figure shows an SCv2000/SCv2020 cabled to two expansion enclosures forming a single chain.
Figure 60. SCv2000/SCv2020 and Two SC100/SC120 Expansion Enclosures
5.Expansion enclosure 2
To connect additional expansion enclosures, cable the expansion enclosures in series. Cable the top EMM, port B from last enclosure in the chain to the top EMM, port A of the enclosure to add. Then, cable the bottom EMM, port B from last enclosure in the chain to the bottom EMM, port A of the enclosure to add.
Table 4. Connected to Two Expansion Enclosures
Label the
Label the
Prerequisites
Locate the
About this task
Apply cable labels to both ends of each SAS cable to indicate the chain number and side (A or B).
Steps
1.Starting with the top edge of the label, attach the label to the cable near the connector.
Figure 61. Attach Label to Cable
2.Wrap the label around the cable until it fully encircles the cable. The bottom of each label is clear so that it does not obscure the text.
Figure 62. Wrap Label Around Cable
3.Apply a matching label to the other end of the cable.
Connect Power Cables and Turn on the Storage System
Connect power cables to the storage system components and turn on the hardware.
About this task
???If the storage system is installed without expansion enclosures, connect power cables to the storage system chassis and turn on the storage system.
???If the storage system is installed with expansion enclosures, connect power cables to the expansion enclosure chassis and turn on the expansion enclosures as described in the Dell Storage Center SC100/SC120 Expansion Enclosure Getting Started Guide. After the expansion enclosures are powered on, connect power to the storage system chassis and turn on the storage system.
Steps
1.Ensure that the power switches are in the OFF position before connecting the power cables.
2.Connect the power cables to both power supply/cooling fan modules in the storage system chassis and secure the power cables firmly to the brackets using the straps provided.
Figure 63. Connect the Power Cables
3.Plug the other end of the power cables into a grounded electrical outlet or a separate power source such as an uninterrupted power supply (UPS) or a power distribution unit (PDU).
4.Press both power switches on the rear of the storage system chassis to turn on the storage system.
Figure 64. Turn on the Storage System
When the SCv2000/SCv2020 storage system is powered on, there is a delay while the storage system prepares to start up. During the first minute, the only indication that the storage system is
powered on are the LEDs on the storage controllers. After the
5.Wait until the green diagnostic LEDs on the back of each storage controller match the pattern shown in Figure 65. Storage Controller Diagnostic LEDs. This pattern indicates that a storage controller has started up successfully.
NOTE: It may take up to five minutes for a storage controller to completely start up.
Figure 65. Storage Controller Diagnostic LEDs
5
Discover and Configure the Storage
Center
The Discover and Configure Uninitialized SCv2000 Series Storage Centers wizard allows you to set up a Storage Center to make it ready for volume creation.
Use the Dell Storage Client to discover and configure the Storage Center. After configuring a Storage Center, you can set up a localhost, VMware vSphere host, or VMware vCenter host using the host setup wizards.
The storage system hardware must be installed and cabled before the Storage Center can be configured.
Worksheet to Record System Information
Use the following worksheet to record the information that is needed to install the SCv2000/SCv2020 storage system.
Storage Center Information
Gather and record the following information about the Storage Center network and the administrator user.
iSCSI Fault Domain Information
For a storage system with iSCSI
NOTE: For a storage system deployed with two Ethernet switches, Dell recommends setting up each fault domain on separate subnets.
Additional Storage Center Information
The Network Time Protocol (NTP) and Simple Mail Transfer Protocol (SMTP) server information is optional. The proxy server information is also optional, but it may be required to complete the Discover and Configure Uninitialized SCv2000 Series Storage Centers wizard.
Fibre Channel Zoning Information
For a storage system with Fibre Channel
Locating Your Service Tag
Your storage system is identified by a unique Service Tag number.
You can find the Service Tag number on the service luggage tag located next to the front panel display. The Service Tag number is also located on the back of the storage system chassis. Dell uses this information to route support calls to the appropriate personnel.
Supported Operating Systems for Storage Center Automated Setup
Setting up a Storage Center using the Discover and Configure Uninitialized SCv2000 Series Storage Centers wizard and the Host Setup wizards requires
???Red Hat Enterprise Linux 6 or later
???SUSE Linux Enterprise 12 or later
???Windows Server 2008 R2 or later
Install and Use the Dell Storage Client
You must start the Dell Storage Client as an Administrator to run the Discover and Configure Uninitialized SCv2000 Series Storage Centers wizard.
1.Go to www.dell.com/support and download the Dell Enterprise Manager software.
2.Install the Enterprise Manager Client on the host server.
To discover and configure a Storage Center, the software must be installed on a host server that is on the same subnet as the storage system.
3.To start the software on a Windows computer,
4.Click Discover and Configure Uninitialized SCv2000 Series Storage Centers. The Discover and Configure Uninitialized SCv2000 Series Storage Centers wizard appears.
Discover and Select an Uninitialized Storage Center
The first page of the Discover and Configure Uninitalized SCv2000 Series Storage Centers wizard provides a list of prerequisite actions and information required before setting up a Storage Center.
Prerequisites
???Make sure that the Storage Center hardware is physically attached to all necessary networks and powered on.
???The host server, on which the Dell Storage Client software is installed, must be on the same subnet or VLAN as the Storage Center.
???Layer 2 multicast must be allowed on the network.
Steps
1.Make sure that you have the required information that is listed on the first page of the wizard. This information is needed to configure the Storage Center.
2.Click Next. The Select a Storage Center to Initialize page appears and lists the uninitialized Storage Centers discovered by the wizard.
NOTE: If the wizard does not discover the Storage Center that you want to initialize, perform one of the following actions:
???Ensure that the Storage Center is physically attached to all necessary networks and powered on. Then click Rediscover.
???Click Troubleshoot Storage Center Hardware Issue to learn more about reasons why the Storage Center is not discoverable.
???Click Manually Discover Storage Center via MAC Address to enter the MAC address for the Storage Center.
3.Select the Storage Center to initialize.
4.(Optional) Click Enable Storage Center Indicator to turn on the indicator light for the selected Storage Center. You can use the indicator to verify that you have selected the correct Storage Center.
5.Click Next.
6.If the Storage Center is partially configured, the Storage Center login pane appears. Enter the management IPv4 address and the Admin password for the Storage Center, then click Next to continue.
Set System Information
The Set System Information page allows you to enter Storage Center and controller configuration information to use when connecting to the Storage Center using Dell Storage Client.
1.Enter a descriptive name for the Storage Center in the Storage Center Name field.
2.Enter the system management IPv4 address for the Storage Center in the Management IPv4 Address field. The Management IPv4 Address is the IP address used to manage the Storage Center and is different than a controller IPv4 address.
3.Enter an IPv4 address for the management port of each controller.
NOTE: The controller IPv4 addresses and Management IPv4 Address must be within the same subnet.
4.Enter the subnet mask of the management network in the Subnet Mask field.
5.Enter the gateway address of the management network in the Gateway IPv4 Address field.
6.Enter the domain name of the management network in the Domain Name field.
7.Enter the DNS server addresses of the management network in the DNS Server and Secondary DNS Server fields.
8.Click Next. The Set Administration Information page appears.
Set Administrator Information
The Set Administrator Information page allows you to set a new password and an email address for the Admin user.
1.Enter a new password for the default Storage Center administrator user in the New Admin Password and Confirm Password fields.
2.Enter the email address of the default Storage Center administrator user in the Admin Email Address field.
3.Click Next.
???For a Fibre Channel or SAS storage system, the Confirm Configuration page appears.
???For an iSCSI storage system, the Configure iSCSI Fault Domains page appears.
Configure iSCSI Fault Domains
For a Storage Center with iSCSI
1.(Optional) On the Configure iSCSI Fault Domains page, click More information about fault domains or How to set up an iSCSI network to learn more about these topics.
2.Click Next.
NOTE: If there are down iSCSI ports, a dialog box appears that allows you to unconfigure down iSCSI ports. Unconfiguring the down iSCSI ports will prevent unnecessary alerts.
3.On the Configure iSCSI HBA Fault Domain 1 page, enter network information for the fault domain and its ports.
NOTE: Make sure that all the IP addresses for iSCSI Fault Domain 1 are in the same subnet.
4.Click Next.
5.On the Configure iSCSI HBA Fault Domain 2 page, enter network information for the fault domain and its ports. Then click Next.
NOTE: Make sure that all the IP addresses for iSCSI Fault Domain 2 are in the same subnet.
6.Click Next.
Confirm the Storage Center Configuration
Make sure that the configuration information shown on the Confirm Configuration page is correct before continuing.
1.Verify that the Storage Center settings are correct.
For an iSCSI storage system, verify that the iSCSI Fault Domain settings are correct.
To copy the configuration information to the clipboard so it can be pasted into a document, click
Copy to clipboard.
2.If the configuration information is correct, click Apply Configuration.
If the configuration information is incorrect, click Back and enter the correct information.
NOTE: After the Apply Configuration button is clicked, the configuration cannot be changed until after the Storage Center is fully configured.
Initialize the Storage Center
The Storage Center sets up the system using the information provided on the previous pages.
1.The Storage Center performs system setup tasks. The Initialize Storage Center page displays the status of the system setup tasks.
To learn more about the initialization process, click More information about Initialization.
???If one or more of the system setup tasks fails, click Troubleshoot Initialization Error to learn how to resolve the issue.
???If the Configuring Disks task fails, click View Disks to see the status of the disks detected by the Storage Center.
???If any of the Storage Center
2.When all of the Storage Center setup tasks are complete, click Next.
Review Fibre Channel
For a Storage Center with Fibre Channel
1.(Optional) On the Fault Domains page, click More information about fault domains to learn more about fault domains.
2.Click Next.
3.On the Review
4.Using the information provided on the Review
5.Click Next.
Review SAS
For a Storage Center with SAS
1.(Optional) On the Fault Domains page, click More information about fault domains to learn more about fault domains.
2.Click Next.
3.On the Review
4.Click Next.
Configure Time Settings
Configure an NTP server to set the time automatically or set the time and date manually.
1.From the Region and Time Zone
2.Select Use NTP Server and enter the host name or IPv4 address of the NTP server, or select Set Current Time and set the time and date manually.
3.Click Next.
Configure SMTP Server Settings
Enable SMTP email to receive information from the Storage Center about errors, warnings, and events.
1.Place a check next to Enable SMTP Email.
2.Enter the SMTP mail server, backup SMTP mail server, email address, and subject line information.
3.Click Test Server to check the connectivity from the Storage Center to the SMTP server.
4.(Optional) Place a check next to Use Authorized Login, and then enter the ID and password.
5.Click Next.
Configure Key Management Server Settings
The Key Management Server Settings page appears if supported by the Storage Center license. Use this page to enter network settings and select the certificate files.
1.Enter network settings for the server.
2.Enter the user name and password.
3.Select the SSL certificate files.
4.Click Next.
The Configure Ports page appears.
Review the SupportAssist Data Collection and Storage
Agreement
The SupportAssist Data Collection and Storage page displays the text of the SupportAssist data agreement and allows you to accept or opt out of SupportAssist.
1.To allow SupportAssist to collect diagnostic data and send this information to technical support, select By checking this box you accept the above terms.
2.Click Next.
3.If you did not select By checking this box you accept the above terms, the SupportAssist Recommended pane appears.
???Click No to return to the SupportAssist Data Collection and Storage page and accept the agreement.
???Click Yes to opt out of SupportAssist and proceed to the Update Storage Center page.
Advantages and Benefits of Dell SupportAssist
As an integral part for Dell???s ability to provide best of class support for your Enterprise class products, Dell SupportAssist proactive provides the information required to diagnose support issues, enabling the most efficient support possible and reducing the effort required by you.
A few key benefits of SupportAssist are:
???Enables proactive service requests and
???Automatic support case creation based on event alerting
???Enables ProSupport Plus and optimizes service delivery
???Automatic health checks
???Enables remote Storage Center updates
Dell strongly recommends enabling comprehensive support service at time of incident and proactive service with SupportAssist.
Provide Contact Information
Enter contact information for technical support to use when sending
1.Enter contact information.
2.To receive SupportAssist emails, select Yes, I would like to receive emails from Dell SupportAssist when issues arise, including hardware failure notifications.
3.Select the preferred contact method, language, and available times.
4.Enter a shipping address where replacement Storage Center components can be sent.
5.Click Next.
Update Storage Center
The Storage Center attempts to contact the SupportAssist Update Server to check for updates.
???If no update is available, the Storage Center Up to Date page appears. Click Next.
???If an update is available, the current and available versions are listed.
a.Click Install to update to the latest version.
b.If the update fails, click Retry Update to try to update again.
c.When the update is complete, click Next.
???If the SupportAssist Data Collection and Storage Agreement was not accepted, the Storage Center cannot check for updates.
??? To proceed without checking for an update, click Next .
??? To accept the agreement and check for an update:
a.Click Accept SupportAssist Data Collection and Storage Agreement to review the agreement.
b.Select By checking this box you accept the above terms.
c.Click Next. The Storage Center attempts to contact the SupportAssist Update Server to check for updates.
???The Setup SupportAssist Proxy Settings dialog box appears if the Storage Center cannot connect to the Dell SupportAssist Update server. If the site does not have direct access to the Internet but uses a web proxy, configure the proxy settings:
a.Select Enabled.
b.Enter the proxy settings.
c.Click OK. The Storage Center attempts to contact the SupportAssist Update Server to check for updates.
Complete Configuration and Perform Next Steps
The Storage Center is now configured. The Configuration Complete page provides links to a Dell Storage Client tutorial and wizards to perform the next setup tasks.
1.(Optional) Click one of the Next Steps to configure a localhost, configure a VMware host, or create a volume.
When you have completed the step, you are returned to the Configuration Complete page.
2.(Optional) Click one of the Advanced Steps to configure embedded iSCSI ports or modify BMC settings.
When you have completed the step, you are returned to the Configuration Complete page.
3.Click Finish to exit the wizard.
Set Up a localhost or VMware Host
After configuring a Storage Center, you can set up block level storage for a localhost, VMware vSphere host, or VMware vCenter.
Set Up a localhost from Initial Setup
Configure a localhost to access block level storage on the Storage Center.
Prerequisites
???Client must be running on a system with a
???The Dell Storage Client must be run by a Dell Storage Client user with the Administrator privilege.
???On a Storage Center with Fibre Channel IO ports, configure Fibre Channel zoning before starting this procedure.
Steps
1.On the Configuration Complete page of the Discover and Configure Storage Center wizard, click Set up block level storage for this host.
The Set up localhost for Storage Center wizard appears.
???If the Storage Center has iSCSI ports and the host is not connected to any interface, the Log into Storage Center via iSCSI page appears. Select the target fault domains, and then click Log In.
???In all other cases, the Verify localhost Information page appears. Proceed to the next step.
2.On the Verify localhost Information page, verify that the information is correct. Then click Create Server.
The server definition is created on the Storage Center for the connected and partially connected initiators.
3.The Host Setup Successful page displays the best practices that were set by the wizard and best practices that were not set. Make a note of any best practices that were not set by the wizard. It is recommended that these updates are applied manually before starting IO to the Storage Center.
4.(Optional) Place a check next to Create a Volume for this host to create a volume after finishing host setup.
5.Click Finish.
Set Up a VMware vSphere Host from Initial Setup
Configure a VMware vSphere host to access block level storage on the Storage Center.
Prerequisites
???Client must be running on a system with a
???The Dell Storage Client must be run by a Dell Storage Client user with the Administrator privilege.
???On a Storage Center with Fibre Channel IO ports, configure Fibre Channel zoning before starting this procedure.
About this task
NOTE: Block level storage cannot be set up for a VMware cluster on a ed Storage Center with SAS IO ports.
Steps
1.On the Configuration Complete page of the Discover and Configure Storage Center wizard, click Configure VMware vSpheres to access a Storage Center.
The Set up VMware Host on Storage Center wizard appears.
2.Enter the IP address or hostname, the user name and password. Then click Next.
???If the Storage Center has iSCSI ports and the host is not connected to any interface, the Log into Storage Center via iSCSI page appears. Select the target fault domains, and then click Log In.
???In all other cases, the Verify vSpheres Information page appears. Proceed to the next step.
3.Select an available port, and then click Create Server. The server definition is created on the Storage Center.
4.The Host Setup Successful page displays the best practices that were set by the wizard and best practices that were not set. Make a note of any best practices that were not set by the wizard. It is recommended that these updates are applied manually before starting IO to the Storage Center.
5.(Optional) Place a check next to Create a Volume for this host to create a volume after finishing host setup.
6.Click Finish.
Set Up a VMware vCenter Host from Initial Setup
Configure a VMware vCenter cluster to access block level storage on the Storage Center.
Prerequisites
???Client must be running on a system with a
???The Dell Storage Client must be run by a Dell Storage Client user with the Administrator privilege.
???On a Storage Center with Fibre Channel IO ports, configure Fibre Channel zoning before starting this procedure.
About this task
NOTE: Block level storage cannot be set up for a VMware vCenter on a Storage Center with SAS IO ports.
Steps
1.On the Configuration Complete page of the Discover and Configure Storage Center wizard, click Configure VMware vSpheres to access a Storage Center.
The Set up VMware Host on Storage Center wizard appears.
2.Enter the IP address or hostname, the user name and password. Then click Next.
???If the Storage Center has iSCSI ports and the host is not connected to any interface, the Log into Storage Center via iSCSI page appears. Select the hosts and target fault domains, and then click
Log In.
???In all other cases, the Verify vCenters Information page appears. Proceed to the next step.
3.Select an available port, and then click Create Servers.
The server definition is created on the Storage Center for each of the connected or partially connected hosts.
4.The Host Setup Successful page displays the best practices that were set by the wizard and best practices that were not set. Make a note of any best practices that were not set by the wizard. It is recommended that these updates are applied manually before starting IO to the Storage Center.
5.Click Finish.
Configure Embedded iSCSI Ports
Configure the embedded Ethernet ports on the Storage Center for use as iSCSI ports.
1.Configure the fault domain and ports for iSCSI Embedded Domain 1.
a.Enter the target IPv4 address, subnet mask, and gateway for the fault domain.
b.Enter an IPv4 address for each port in the fault domain.
NOTE: Make sure that all the IP addresses for iSCSI Embedded Domain 1 are in the same subnet.
2.If the Flex Port license is installed, configure the fault domain and ports for Flex Port Domain 1.
a.Enter the target IPv4 address, subnet mask, and gateway for the fault domain.
b.Enter an IPv4 address for each port in the fault domain.
NOTE: Make sure that all the IP addresses for iSCSI Embedded Domain 1 are in the same subnet.
3.Click OK.
6
Perform
Perform connectivity and failover tests to make sure that the Storage Center deployment was successful.
Verify Connectivity and Failover
This section describes the general steps needed to verify that Storage Center is set up properly and performs failover correctly.
The process includes creating test volumes, copying data to verify connectivity, and shutting down a storage controller to verify failover and MPIO functionality.
Create Test Volumes
Connect a server to the Storage Center, create one or more test volumes, and map them to the server to prepare for connectivity and failover testing.
About this task
Steps
1.Configure a localhost to access the Storage Center using the Set up localhost on Storage Center wizard.
2.Connect to the Storage Center using the Dell Storage Client.
3.Create a 25 GB test volume named TestVol1 and map it to the top storage controller (storage controller 1).
a.Click the Storage tab.
b.From the Storage tab navigation pane, select the Volumes node.
c.Click Create Volume. The Create Volume wizard appears.
d.Enter TestVol1 in the Name field, then click Next.
e.Set the volume size to 25 GB, then click Next.
f.Select the disk folder to use, then click Next.
g.Select the replay profile to use, then click Next.
h.Select the server to which to map the volume and click Advanced Mapping.
i.Clear the check box under Restrict Mapping Paths and select the controller on which to activate the volume.
j.Click OK and click Next.
k.Click Finish.
4.Repeat the previous steps to create 25 GB volume named TestVol2 and map it to the bottom storage controller (storage controller 2).
5.Partition and format the test volumes on the server.
Test Basic Connectivity
Verify basic connectivity by copying data to the test volumes.
1.Connect to the server to which the volumes are mapped.
2.Create a folder on the TestVol1 volume, copy at least 2 GB of data to the folder, and verify that the data copied successfully.
3.Create a folder on the TestVol2 volume, copy at least 2 GB of data to the folder, and verify that the data copied successfully
Test Storage Controller Failover
Test the Storage Center to make sure that a storage controller failover does not interrupt IO.
1.Connect to the server, create a Test folder on the server, and copy at least 2 GB of data into it.
2.Restart the top storage controller while copying data to verify that the failover event does not interrupt IO.
a.Copy the Test folder to the TestVol1 volume.
b.During the copy process, restart the top storage controller (the storage controller through which TestVol1 is mapped) by selecting it from the Hardware tab and clicking Shutdown/Restart Controller.
c.Verify that the copy process continues while the storage controller restarts.
d.Wait several minutes and verify that the storage controller has finished restarting.
3.Restart the bottom storage controller while copying data to verify that the failover event does not interrupt IO.
a.Copy the Test folder to the TestVol2 volume.
b.During the copy process, restart the bottom storage controller (the storage controller through which the TestVol2 is mapped) by selecting it from the Hardware tab and clicking Shutdown/ Restart Controller.
c.Verify that the copy process continues while the storage controller restarts.
d.Wait several minutes and verify that the storage controller has finished restarting.
Test MPIO
Perform the following tests for a Storage Center with Fibre Channel or iSCSI
1.Create a Test folder on the server and copy at least 2GB of data into it.
2.Make sure that the server is configured to use load balancing MPIO
3.Manually disconnect a path while copying data to TestVol1 to verify that MPIO is functioning correctly.
a.Copy the Test folder to the TestVol1 volume.
b.During the copy process, disconnect one of the paths and verify that the copy process continues.
c.Reconnect the path.
4.Repeat the previous steps as necessary to test additional paths.
5.Restart the storage controller that contains the active path while IO is being transferred and verify that the IO process continues.
6.If the
Clean up Test Volumes
After testing is complete, delete the volumes used for testing.
1.Connect to the server to which the volumes are mapped and remove the volumes.
2.Connect to the Storage Center using the Dell Storage Client.
3.Click the Storage tab.
4.From the Storage tab navigation pane, select the Volumes node.
5.Select the volumes to delete.
6.
7.Click OK
Sending Diagnostic Data Using Dell SupportAssist
Use Dell SupportAssist to send diagnostic data to Dell Technical Support Services.
1.Click Send SupportAssist Data Now. The Send Support Assist Data Now dialog box appears.
2.Select Storage Center Configuration and Detailed Logs.
3.Click OK.
Label SC100/SC120 Expansion Enclosures
SC100/SC120 expansion enclosures do not have displays to indicate the expansion enclosure ID assigned by Storage Center.
About this task
To facilitate easy identification in the rack, use Dell Storage Client to match each expansion enclosure ID to a Service Tag. Locate the Service Tag on the back of each expansion enclosure and then label it with the correct expansion enclosure ID.
NOTE: If the expansion enclosure is deleted from Storage Client and then added back in, the expansion enclosure is assigned a new index number, requiring a label change.
Steps
1.Click the Hardware tab.
2.In the Hardware tab navigation pane, select the Enclosures node.
3.In the
4.Create a label with the enclosure ID.
NOTE: If the name of the enclosure is Enclosure - 2, the enclosure ID is 2.
5.Locate the expansion enclosure with the recorded Service Tag and apply the ID label to the
A
Adding or Removing an Expansion Enclosure
This section describes how to add an expansion enclosure to a storage system and how to remove an expansion enclosure from a storage system.
Adding Multiple Expansion Enclosures to a Storage System Deployed without Expansion Enclosures
Use caution when adding expansion enclosures to a live Storage Center system to preserve the integrity of the existing data.
Prerequisites
Install the expansion enclosures in a rack and, but do not connect the expansion enclosures to the storage system. For more information, see the Dell Storage Center SC100/SC120 Expansion Enclosure Getting Started Guide
Steps
1.Cable the expansion enclosures together to form a chain.
2.Connect to the Storage Center using the Dell Storage Client.
3.Check the disk count of the Storage Center system before adding the expansion enclosure.
4.Click the Hardware tab and select Enclosures node in the Hardware tab navigation pane.
5.Click Add Enclosure. The Add New Enclosure wizard starts.
a.Click Next to validate the existing cabling.
b.Select the enclosure type and click Next.
c.If the drives are not installed, install the drives in the expansion enclosures.
d.Turn on the expansion enclosure. When the drives spin up, make sure that the front panel and power status LEDs show normal operation.
e.Click Next.
f.Add the expansion enclosure to the
g.Add the expansion enclosure to the
h.Click Finish.
6.To manually manage new unassigned disks:
a.Click the Storage tab.
b.In the Storage tab navigation pane, select the Disks node.
c.Click Manage Unassigned Disks. The Manage Unassigned Disks dialog box appears.
d.From the Disk Folder
e.Select Perform RAID rebalance immediately.
f.Click OK.
For more information, see the Dell Enterprise Manager Administrator???s Guide.
7.Label the new
Related Links
Cable the Expansion Enclosures Together
Check the Current Disk Count before Adding Expansion Enclosures
Add the Expansion Enclosures to the
Add the Expansion Enclosures to the
Cable the Expansion Enclosures Together
Cable the expansion enclosures together to form a chain, but do not connect the chain to the storage system.
1.Connect a SAS cable from expansion enclosure 1: top, port B to expansion enclosure 2: top, port A.
2.Connect a SAS cable from expansion enclosure 1: bottom, port B to expansion enclosure 2: bottom, port A.
Figure 66. Cable the Expansion Enclosures Together
3.Repeat the previous steps to connect additional expansion enclosures to the chain.
Check the Current Disk Count before Adding Expansion Enclosures
Use the Dell Storage Client to determine the number of drives that are currently accessible to the Storage Center.
1.Connect to the Storage Center using the Dell Storage Client.
2.Select the Storage tab.
3.In the Storage tab navigation pane, select the Disks node.
4.On the Disks tab, record the number of drives that are accessible by Storage Center.
Compare this value to the number of drives accessible by the Storage Center after adding expansion enclosures to the storage system.
Add the Expansion Enclosures to the
Connect the expansion enclosures to one chain at a time to maintain drive availability.
1.Disconnect the
Remove the SAS cable that connects storage controller 1: port A to storage controller 2: port B.
Figure 67. Remove the
3.Storage controller 2
2.Add the expansion enclosures to the
a.Connect a SAS cable from storage controller 1: port A to the first expansion enclosure in the chain, top EMM, port A.
b.Connect a SAS cable from storage controller 2: port B to the last expansion enclosure in the chain, top EMM, port B.
Figure 68. Connect the
5.Expansion enclosure 2
Add the Expansion Enclosures to the
Connect the expansion enclosures to one chain at a time to maintain drive availability.
1.Disconnect the
Remove the SAS cable that connects storage controller 1: port B to storage controller 2: port A.
Figure 69. Remove the
5.Expansion enclosure 2
2.Add the expansion enclosures to the
a.Connect a SAS cable from storage controller 1: port B to expansion enclosure 2: bottom EMM, port B.
b.Connect a SAS cable from storage controller 2: port A to expansion enclosure 1: bottom EMM, port A.
Figure 70. Connect the
5.Expansion enclosure 2
Label the
Label the
Prerequisites
Locate the
About this task
Apply cable labels to both ends of each SAS cable to indicate the chain number and side (A or B).
Steps
1.Starting with the top edge of the label, attach the label to the cable near the connector.
Figure 71. Attach Label to Cable
2.Wrap the label around the cable until it fully encircles the cable. The bottom of each label is clear so that it does not obscure the text.
Figure 72. Wrap Label Around Cable
3.Apply a matching label to the other end of the cable.
Adding a Single Expansion Enclosure to a Chain Currently in Service
Use caution when adding an expansion enclosure to a live Storage Center system to preserve the integrity of the existing data.
Prerequisites
Install the expansion enclosure in a rack, but do not connect the expansion enclosure to the storage system. For more information, see the Dell Storage Center SC100/SC120 Expansion Enclosure Getting Started Guide.
About this task
To add an expansion enclosure to an existing chain, connect the expansion enclosure to the end of the chain.
Steps
1.Connect to the Storage Center using the Dell Storage Client.
2.Check the disk count of the Storage Center system before adding the expansion enclosure.
3.Click the Hardware tab and select Enclosures in the Hardware tab navigation pane.
4.Click Add Enclosure. The Add New Enclosure wizard starts.
a.Confirm the details of your current install and click Next to validate the existing cabling.
b.Select the enclosure type and click Next.
c.If the drives are not installed, install the drives in the expansion enclosure.
d.Turn on the expansion enclosure. When the drives spin up, make sure that the front panel and power status LEDs show normal operation.
e.Click Next.
f.Add the expansion enclosure to the
g.Add the expansion enclosure to the
h.Click Finish.
5.To manually manage new unassigned disks:
a.Click the Storage tab.
b.In the Storage tab navigation pane, select the Disks node.
c.Click Manage Unassigned Disks. The Manage Unassigned Disks dialog box appears.
d.From the Disk Folder
e.Select Perform RAID rebalance immediately.
f.Click OK.
For more information, see the Dell Enterprise Manager Administrator???s Guide.
6.Label the new
Related Links
Check the Current Disk Count before Adding Expansion Enclosures
Add an Expansion Enclosure to the
Add an Expansion Enclosure to the
Check the Disk Count before Adding an Expansion Enclosure
Use the Dell Storage Client to determine the number of drives that are currently accessible to the Storage Center.
1.Connect to the Storage Center using the Dell Storage Client.
2.Select the Storage tab.
3.In the Storage tab navigation pane, select the Disks node.
4.On the Disks tab, record the number of drives that are accessible by Storage Center.
Compare this value to the number of drives accessible by the Storage Center after adding an expansion enclosure to the storage system.
Add an Expansion Enclosure to the
Connect the expansion enclosure to one chain at a time to maintain drive availability
1.Turn on the expansion enclosure being added. When the drives spin up, make sure that the front panel and power status LEDs show normal operation.
2.Disconnect the
???Disconnect the SAS cable from storage controller 1, port A
???Disconnect the SAS cable from storage controller 2, port B
Figure 73. Disconnect
3.Move the cable from expansion enclosure 1: top EMM, port B to the new expansion enclosure (2): top EMM, port B.
4.Use a new SAS cable to connect expansion enclosure 1: top EMM, port B to the new expansion
enclosure (2): top EMM, port A.
Figure 74. Connect
5.New expansion enclosure (2)
5.Reconnect the
a. Reconnect expansion enclosure 1: top EMM, port A to storage controller 1: port A.
b. Connect the new expansion enclosure (2): top EMM, port B to storage controller 2: port B.
Figure 75. Reconnect
Add an Expansion Enclosure to the
Connect the expansion enclosure to one chain at a time to maintain drive availability.
1.Disconnect the
???Disconnect the SAS cable from storage controller 1: port B.
???Disconnect the SAS cable from storage controller 2, port A.
Figure 76. Disconnect
5.New expansion enclosure (2)
2.Move the cable from expansion enclosure 1: bottom EMM, port B to the new expansion enclosure
(2): bottom EMM, port B.
3.Use a new SAS cable to connect expansion enclosure 1: bottom EMM, port B to the new expansion
enclosure (2): bottom EMM, port A.
Figure 77. Connect
5.New expansion enclosure (2)
4.Reconnect the
a.Reconnect expansion enclosure 1: bottom EMM, port A to storage controller 2: port A.
b.Connect the new expansion enclosure (2): bottom EMM, port B to storage controller 1: port B.
Figure 78. Reconnect
Label the
Label the
Prerequisites
Locate the
About this task
Apply cable labels to both ends of each SAS cable to indicate the chain number and side (A or B).
Steps
1.Starting with the top edge of the label, attach the label to the cable near the connector.
Figure 79. Attach Label to Cable
2.Wrap the label around the cable until it fully encircles the cable. The bottom of each label is clear so that it does not obscure the text.
Figure 80. Wrap Label Around Cable
3.Apply a matching label to the other end of the cable.
Removing an Expansion Enclosure from a Chain Currently in Service
To remove an expansion enclosure, disconnect the expansion enclosure from one side of the chain at a time.
About this task
During this process, one side of the chain is disconnected, and the Storage Center directs all IO to other the side of the chain, which remains connected.
CAUTION: Make sure that your data is backed up before removing an expansion enclosure.
Steps
1.Connect to the Storage Center using the Dell Storage Client.
2.Use the Dell Storage Client to release the disks in the expansion enclosure.
3.Select the expansion enclosure to remove and click Remove Enclosure. The Remove Enclosure wizard starts.
4.Confirm the details of your current install and click Next to validate the cabling.
5.Locate the expansion enclosure in the rack. Click Next.
6.Disconnect the
a.Disconnect the
Next.
b.Reconnect the A side cables to exclude the expansion enclosure from the chain. Click Next to validate the cabling.
7.Disconnect the
a.Disconnect the
Next
b.Reconnect the
8.Click Finish.
Related Links
Release the Disks in the Expansion Enclosure
Disconnect the
Disconnect the
Release the Disks in the Expansion Enclosure
Use the Dell Storage Client to release the disks in an expansion enclosure before removing the expansion enclosure.
About this task
Releasing disks causes all of the data to move off the disks.
NOTE: Do not release disks unless the remaining disks have enough free space for the
Steps
1.Connect to the Storage Center using the Dell Storage Client.
2.Click the Hardware tab.
3.In the Hardware tab navigation pane, expand the enclosure to remove.
4.Select the Disks node.
5.Select all of the disks in the expansion enclosure.
6.
7.Select Perform RAID rebalance immediately.
8.Click OK.
When all of the drives in the expansion enclosure are in the Unassigned disk folder, the expansion enclosure is safe to remove.
Disconnect the
Disconnect the
About this task
CAUTION: To disconnect the
Steps
1.Disconnect the
enclosure 1: top EMM, port A.
2.In the Dell Storage Client, verify that the
3.Remove the
2: top EMM, port A.
Figure 81. Disconnecting the SC100/SC120 Expansion Enclosure from the
5.Expansion enclosure 2
4.Reconnect the
5.Connect the other end of the
5.Expansion enclosure 2
Disconnect the
Disconnect the
About this task
CAUTION: To disconnect the
Steps
1.Disconnect the
enclosure 1: bottom EMM, port A.
2.In the Dell Storage Client, verify that the
3.Remove the
enclosure 2: bottom EMM, port A.
Figure 83. Disconnecting the SC100/SC120 Expansion Enclosure from the
5.Expansion enclosure 2
4.Reconnect the
5.Connect the other end of the
Figure 84. Expansion Enclosure Disconnected
5.Expansion enclosure 1
B
Troubleshooting Storage Center
This appendix contains troubleshooting steps for common Storage Center issues.
Troubleshooting Storage Controllers
Use these steps to troubleshoot storage controllers.
1.Check the status of the storage controller using the Dell Storage Client.
2.Check the pins and reseat the storage controller.
a.Remove the storage controller.
b.Verify that the pins on the storage system backplane and the storage controller are not bent.
c.Reinstall the storage controller.
3.Determine the status of the storage controller link status indicators. If the indicators are not green, check the cables.
a.Shut down the storage controller.
b.Reseat the cables on the storage controller.
c.Restart the storage controller.
d.Recheck the link status indicators. If the link status indicators are not green, replace the cables.
Troubleshooting Hard Drives
Use these steps to troubleshoot hard drives.
1.Check the status of the hard drive using the Dell Storage Client.
2.Determine the status of the hard drive indicators.
???If the hard drive status indicator blinks amber on 2 seconds / off 1 second, the hard drive has failed.
???If the hard drive status indicator is not lit, proceed to the next step.
3.Check the connectors and reseat the hard drive.
a.Remove the hard drive.
b.Check the hard drive and the backplane to ensure that the connectors are not damaged.
c.Reinstall the hard drive. Make sure the hard drive makes contact with the backplane.
Troubleshooting Expansion Enclosures
Use these steps to troubleshoot expansion enclosures.
1.Check the status of the expansion enclosure using the Dell Storage Client.
2.If an expansion enclosure and/or drives are missing in the Dell Storage Client, you may need to check for and install Storage Center updates to use the expansion enclosure and/or drives.
3.If an expansion enclosure firmware update fails, check the