ConnectX??-3 Dual Port 40Gb/s and 56Gb/s Mezzanine Card for Dell User Manual

0J05YT, 0K6V3V

Rev 1.0

www.mellanox.com

NOTE:

THIS HARDWARE, SOFTWARE OR TEST SUITE PRODUCT (???PRODUCT(S)???) AND ITS RELATED DOCUMENTATION ARE PRO-

VIDED BY MELLANOX TECHNOLOGIES ???AS-IS??? WITH ALL FAULTS OF ANY KIND AND SOLELY FOR THE PURPOSE OF

AIDING THE CUSTOMER IN TESTING APPLICATIONS THAT USE THE PRODUCTS IN DESIGNATED SOLUTIONS. THE CUS-

TOMER'S MANUFACTURING TEST ENVIRONMENT HAS NOT MET THE STANDARDS SET BY MELLANOX TECHNOLOGIES

TO FULLY QUALIFY THE PRODUCTO(S) AND/OR THE SYSTEM USING IT. THEREFORE, MELLANOX TECHNOLOGIES CAN-

NOT AND DOES NOT GUARANTEE OR WARRANT THAT THE PRODUCTS WILL OPERATE WITH THE HIGHEST QUALITY.

ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MER-

CHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT ARE DISCLAIMED. IN NO EVENT

SHALL MELLANOX BE LIABLE TO CUSTOMER OR ANY THIRD PARTIES FOR ANY DIRECT, INDIRECT, SPECIAL, EXEM-

PLARY, OR CONSEQUENTIAL DAMAGES OF ANY KIND (INCLUDING, BUT NOT LIMITED TO, PAYMENT FOR PROCURE-

MENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)

HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT

(INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY FROM THE USE OF THE PRODUCT(S) AND RELATED

DOCUMENTATION EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.

?? Copyright 2012. Mellanox Technologies. All rights reserved.

Mellanox??, BridgeX??, ConnectX??, InfiniBlast??, InfiniBridge??, InfiniHost??, InfiniRISC??, InfiniScale??, InfiniPCI??, PhyX??, CORE- Direct??, Virtual Protocol Interconnect??, Voltaire?? and SwitchX?? are registered trademarks of Mellanox Technologies, Ltd. FabricIT???, MLNX-OS??? and Unbreakable-Link??? are trademarks of Mellanox Technologies, Ltd. All other marks and names mentioned herein may be trademarks of their respective companies.

Table of Contents

Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 List of Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 List of Figures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 About this Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

Intended Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Related Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Online Resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Document Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

1.1 Cards Covered in this Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 1.2 Finding the GUID/MAC and Serial Number on the Mezzanine Cards . . . . . . . . . . . . . . . . . . . . . . . . . . 9

AppendixB Avertissements de s??curit?? d???installation (French). . . . . . . . . . . . . . . . . . . . . . . . . . 31 AppendixC Installation - Sicherheitshinweise (German). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 AppendixD Advertencias de seguridad para la instalaci??n (Warnings in Spanish) . . . . . . . . . 33

Rev 1.0

List of Tables

List of Figures

Figure 1: 0J05YT Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

Figure 2: Board Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

Figure 3: 0K6V3V Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

Figure 4: Board Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

Figure 5: 0J05YT/0K6V3V Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11

Figure 6: I2C Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

Figure 7: Grounding Clip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19

Figure 8: Blade Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19

Figure 9: Protective Cover in Place . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20

Figure 10: Remove the Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21

Figure 11: Press on the Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21

Figure 12: Single Card in Slot C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22

Figure 13: Two Cards Installed. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22

Figure 14: Device Manager (example) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26

Figure 15: Support Download Assistant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28

Figure 16: Mechanical Drawing of 0J05YT/0K6V3V Mezzanine Card . . . . . . . . . . . . . . . . . . . . . .29

Rev 1.0

Revision History

This document was first printed on February 14, 2012.

Table 1 - Revision History Table

About this Manual

This User Manual describes ConnectX??-3 Dual QSFP Port mezzanine card for the Dell Blade Servers. It provides details as to the interfaces of the board, specifications, required software and firmware for operating the cards, installation instructions, and relevant documentation.

Intended Audience

This manual is intended for the installer and user of the mezzanine cards.

The manual assumes basic familiarity with the InfiniBand?? (IB) network architecture specifica- tions.

Related Documentation

Table 2 - Documents List

Online Resources

???Mellanox Technologies Web pages: http://www.mellanox.com

???Dell Support Web pages: http://support.dell.com

Document Conventions

When discussing memory sizes, MB and MBytes are used in this document to mean size in mega bytes. The use of Mb or Mbits (small b) indicates size in mega bits.

These symbols indicate a situation, status, or condition that may cause harm to people or damage to the equipment.

Rev 1.0

1 Overview

This document is a User Manual for the Mellanox Technologies ConnectX??-3 40Gb/s and 56Gb/ s InfiniBand dual-port mezzanine cards for the Dell Blade Servers. The cards described in this manual have the following main features:

???InfiniBand Architecture Specifications v1.2.1 compliant

???PCI Express 3.0 (1.1 and 2.0 compatible) through an x8 connector up to 8GT/s

???1??s MPI ping latency

???Up to 56Gb/s InfiniBand per port

???CPU off-load of transport operations

???Application Offload

???End-to-end QoS and congestion control

???Hardware-based I/O virtualization

???TCP/UDP/IP stateless offload

???RoHS-R6 compliant

1.1Cards Covered in this Manual

Table 3 - ConnectX-3 Mezzanine Card Details

1.2Finding the GUID/MAC and Serial Number on the Mezzanine Cards

All cards include a label that has the card serial number and the card GUID for InfiniBand protocol on the print side of the card.

Figure 1: 0J05YT Label

Figure 2: Board Label

Figure 3: 0K6V3V Label

Figure 4: Board Label

2 Card Interfaces

2.1I/O Interfaces

Each mezzanine card includes the following interfaces:

???PCI Express (PCIe)

???I2C-compatible connector (for debug)

Figure 5: 0J05YT/0K6V3V Card

2.1.1InfiniBand Interface

The ConnectX??-3 mezzanine cards are compliant with the InfiniBand Architecture Specification, Release 1.2.1. It has two compliant InfiniBand ports with four Tx/Rx pairs of SerDes.

2.1.2PCI Express Interface

The ConnectX??-3 mezzanine cards support PCI Express 3.0 (1.1 and 2.0 compatible) . The device can be either a master initiating the PCI Express bus operations or a slave responding to PCI bus operations.

2.1.3I2C-compatible Interface

A three-pin header on the mezzanine cards is provided as the I2C-compatible interface.

Figure 6: I2C Connector

2.2Power

All adapter cards receive 12V and 3.3V power from the PCI Express connector. All other required power voltages are generated by on-board switch mode regulators. See Appendix A.2,???Specifications,??? on page 30.

2.3Memory

The mezzanine cards support multiple memory devices through the PCI Express, SPI (Flash), and I2C-compatible interfaces.

2.3.1System Memory

The mezzanine cards utilize the PCI Express interface to store and access fabric connection infor- mation on the system memory.

2.3.2SPI

The mezzanine cards include one SPI Flash device accessible via the Flash interface of the Con- nectX??-3 device.

A jumper inserted into the drill on each adapter card indicates to the device whether an on-board Flash device is to be used or not. Table 4 provides information on this jumper.

Table 4 - Jumper Configuration

2.3.3EEPROM

The mezzanine cards incorporate an EEPROM that is accessible through the I2C-compatible inter- face. The EEPROM capacity is 4Kb. The EEPROM is used for storing the Vital Product Data (VPD) and FRU. The PCI VPD (Vital Product Data) layout for each of the mezzanine cards com- plies with the format defined in the PCI 3.0 Specification, Appendix I.

Table 5 - 0J05YT VPD Layout

Table 5 - 0J05YT VPD Layout

Table 5 - 0J05YT VPD Layout

Table 6 - 0K6V3V VPD Layout

Table 6 - 0K6V3V VPD Layout

3 Card Installation

3.1Hardware RequirementsTBD

Before installing the mezzanine card, make sure that the system meets the hardware and software requirements listed in

Table 7 - Jumper Configuration

3.2Installation Kit

Make sure all of the parts are in the kit before you start the installation. If any parts are damaged or missing, call your supplier immediately.

Installation Instructions

Installation of this mezzanine card should only be done by a properly qualified technician or engi- neer. Installation or service not authorized by Dell or performed by unqualified personnel may void guarantees and warranties. Read and follow all safety precautions specified in this document and in the PowerEdge documentation.

Use the documentation supplied with the Dell Blade Servers to remove and replace the blade from the chassis.

The card shown below has grounding clips that must come in contact with the chassis after the card is installed.

Figure 7: Grounding Clip

Make sure that you are properly grounded. Make sure that the equipment, both while in the chas- sis and while removed from the chassis, is properly grounded to prevent ESD.

Figure 8: Blade Server

DIMMS

DIMMS can be hot. Allow sufficient time for the blade components to cool before starting this procedure.

1.Remove the blade from the chassis.

2.Remove the cover from the blade.

3.Open the retaining clip.

The card can be placed in either of the two available slots.

4.Expose the socket to be used for the new card.

a.When replacing an existing card, remove the card from the socket. Grab the card on the edge on the side with UPC number and pull up while gently rocking the card back and forth.

b.For a new installation remove the protective cover enclosing the socket for the card.

Figure 9: Protective Cover in Place

Figure 10: Remove the Cover

Hold the mezzanine card by the edges only.

Line up the mezzanine card so that the pins of the mezzanine card are over the sockets in the blade server.

5.Plug the card into the socket by placing your thumb over the UPC symbol and pressing down until the card reaches the bottom.

Figure 11: Press on the Card

6.Close the retaining clip.

Figure 12: Single Card in Slot C

Figure 13: Two Cards Installed

7.Replace the blade server cover.

8.Replace the blade server into the chassis

3.3Safety Warnings

1.Installation Instructions

Read all installation instructions before connecting the equipment to the power source.

2. Over Temperature

This equipment should not be operated in an area with an ambient temperature exceeding the maximum recommended: ??C (??F).

To guarantee proper air flow, allow at least 8cm (3 inches) of clearance around the ventilation openings.

3. Lightening ??? Electrical Hazard

During periods of lightning activity, do not work on the equipment.

4. Installation of Equipment

This equipment should be installed, replaced, or serviced only by trained and qualified person- nel.

5. Disposal of Equipment =

Disposal of this equipment should be in accordance to all national laws and regulations.

6. Compliance with Local and National Codes

This equipment should be installed in compliance with local and national electrical codes.

4 Driver Software and Firmware

4.1Driver Software

4.1.1Linux

For Linux, download and install the latest OpenFabrics Enterprise Distribution (OFED) software package available via the Mellanox web site at: http://www.mellanox.com => Products => Soft- ware/Drivers => Infiniband & VPI Software/Drivers => Mellanox OFED => Download. Follow the installation instructions included in the download package (also available from the download page). To ensure that communication has been established follow the instructions below.

Check the link status

To check the IB link status, for IB cards, run ???ibstat??? and focus on the Physical state attributes. Example:

> Host# ibstat

LCA 'mlx4_0'

CA type: MT4099

Number of ports: 2

Firmware version: 2.10.2000

Hardware version: 0

Node GUID: 0x0002c903002fefe0

System image GUID: 0x0002c903002fefe3

Port 1:

State: Active

Physical state: LinkUp

Rate: 56

Base lid: 4

LMC: 0

SM lid: 12

Capability mask: 0x02514868

Port GUID: 0x0002c903002fefe1

Link layer: InfiniBand

Port 2:

State: Active

Physical state: LinkUp

Rate: 56

Base lid: 8

LMC: 0

SM lid: 12

Capability mask: 0x02514868

Port GUID: 0x0002c903002fefe2

Link layer: InfiniBand

Check the OFED version

To get the version of the running Mellanox OFED/BXOFED, run the following command:

# ofed_info |head -1

MLNX_OFED_LINUX-1.5.2-2.0.0 (OFED-1.5.2-20101219-1546):

MLNX_OFED_LINUX-1.5.3-0.1.6 (OFED-1.5.3-0.1.6):

Troubleshooting MLNX_OFED Installation

For troubleshooting driver installation, please check Mellanox OFED driver user manual ar http://www.mellanox.com => Support => InfiniBand Products => Mellanox OFED.

4.1.2Windows

For Windows, download and install the latest Mellanox WinOF VPI for Windows software pack- age available via the Mellanox web site at: http://www.mellanox.com => Products => Software/ Drivers => Infiniband & VPI Software/Drivers => Mellanox WinOF VPI => Download. Follow the installation instructions included in the download package (also available from the download page). To ensure that communication has been established follow the instructions below.

Displaying the Device Manager will show the Mellanox adapter devices and an IPoIB (network) device for each port.

Figure 14: Device Manager (example)

Note: If the cards are connected to a managed switch, there is no need to run openSM. Only one OpenSM should run per subnet.In InfiniBand interfaces, OpenSM is installed as a disabled Windows service. To enable it, enter at the command line:

>sc start opensm

4.2FlexBoot

FlexBoot enables remote boot over Boot over InfiniBand (BoIB), or Boot over iSCSI (Bo-iSCSI). This technology is based on the Preboot Execution Environment (PXE) standard specification, and FlexBoot software is based on the open source EtherBoot/gPXE project (see www.etherboot.org). For more information go to http://www.mellanox.com => Products => InfiniBand & VPI Soft- ware/Drivers => FlexBoot => User???s Manual.

4.3Updating Mezzanine Card Firmware

Each card is shipped with the latest version of qualified firmware at the time of manufacturing. Firmware is updated occasionally, and the most recent firmware can be obtained from: http://www.mellanox.com => Support => Download Firmware. Check that the firmware on your card is the latest found on the Mellanox site, if not update to the latest version found on the Mella- nox web site.

Firmware can be updated on the stand alone single card using the flint tool of the Mellanox Firm- ware Tools (MFT) package. This package is available for download, along with its user manual, from the Mellanox Firmware Tools page. See http://www.mellanox.com => Support => Download Firmware Tools.

A firmware binaries table lists a binary file per mezzanine card. The file name of each such binary is composed by combining the firmware name, the firmware release version, and the card part

number. Please contact Mellanox System Support if you cannot find the firmware binary for your mezzanine card.

The following steps describe how to retrieve the PSID (firmware identification) and programmed firmware version of your mezzanine card. They also describe how to update the card with the lat- est firmware version available.

1.Retrieve the PSID and firmware version:

a.Install the MFT package. The package is available at www.mellanox.com => Products => Software/Drivers => InfiniBand & VPI Software/Drivers => Firmware Tools. Make sure to download the package corresponding to your computer???s operating system.

b.Enter: mst start

c.Get the Mellanox mst device name using the command "mst status". The mst device name will be of the form: /dev/mst/mt4099_pci_cr0

d.Get the PSID (firmware identification) and programmed firmware version using the command

2.Compare the programmed firmware version with the latest available.

a.Go to Mellanox???s web site: http://www.mellanox.com/supportdownloader. See Figure 15

b.Enter your card PSID to display the latest firmware

Figure 15: Support Download Assistant

3.If a newer firmware version exists for your mezzanine card, update the firmware as follows:

a.Download the firmware image zip file from the Download Center (see Step 2a above)

b.Unzip the firmware image

c.Burn the firmware image. Enter:

>flint -d /dev/mst/mt4099_pci_cr0 -i <binary image> burn

d.Reboot the computer

e.Enter: mst start

f.Verify that the card firmware was updated successfully

>flint -d /dev/mst/mt4099_pci_cr0 q

Appendix A: Specifications

A.1 Board Mechanical Drawing and Dimensions

The ConnectX??-3 mezzanine card mechanical drawing is depicted in Figure 16.

All dimensions are in millimeters.

All the mechanical tolerances are +/- 0.1mm

Figure 16: Mechanical Drawing of 0J05YT/0K6V3V Mezzanine Card

23.92

64.08

72.36 78.91

57.08

88

Rev 1.0

A.2 Specifications

Table 8 - ConnectX-3 0J05YT/0K6V3V Specifications Table

Appendix B: Avertissements de s??curit?? d???installation (French)

1. Instructions d???installation

Lisez toutes les instructions d???installation avant de brancher le mat??riel ?? la source d???alimentation ??lectrique.

2. Temp??rature excessive

Ce mat??riel ne doit pas fonctionner dans une zone avec une temp??rature ambi- ante d??passant le maximum recommand?? de 55??C (131??F). Un flux d???air de 200LFM ?? cette temp??rature ambiante maximale est n??cessaire. En outre, pour garantir un bon ??coulement de l???air, laissez au moins 8 cm (3 pouces) d???espace libre autour des ouvertures de ventilation.

3. Orages ??? dangers ??lectriques

Pendant un orage, il ne faut pas utiliser le mat??riel.

4. Installation du mat??riel

Ce mat??riel ne doit ??tre install??, remplac?? ou entretenu que par du personnel form?? et qualifi??.

5. Elimination du mat??riel

L?????limination de ce mat??riel doit s???effectuer dans le respect de toutes les l??gis- lations et r??glementations nationales en vigueur.

6. Codes ??lectriques locaux et nationaux

Ce mat??riel doit ??tre install?? dans le respect des codes ??lectriques locaux et nationaux.

Rev 1.0

Appendix C: Installation - Sicherheitshinweise (German)

1. Installationsanleitungen

Lesen Sie alle Installationsanleitungen, bevor Sie das Ger??t an die Stromvers- orgung anschlie??en.

2. ??bertemperatur

Dieses Ger??t sollte nicht in einem Bereich mit einer Umgebungstemperatur ??ber der maximal empfohlenen Temperatur von 55??C (131??F) betrieben werden. Au??erdem sollten mindestens 8 cm (3 in.) Freiraum um die Bel??f- tungs??ffnungen sein, um einen einwandfreien Luftstrom zu gew??hrleisten.

3. Bei Gewitter - Elektrische Gefahr

Arbeiten Sie w??hrend eines Gewitters und Blitzschlag nicht am Ger??t.

4.Ger??teinstallation

Diese Ger??t sollte nur von geschultem und qualifiziertem Personal installiert, ausgetauscht oder gewartet werden.

5. Ger??teentsorgung

Die Entsorgung dieses Ger??ts sollte unter Beachtung aller nationalen Gesetze

Bestimmungen erfolgen.

6. Regionale und nationale elektrische Bestimmungen

Dieses Ger??t sollte unter Beachtung der regionalen und nationalen elektrischen

Bestimmungen installiert werden.

Appendix D: Advertencias de seguridad para la instalaci??n (Warnings in Spanish)

1. Instrucciones de instalaci??n

Antes de conectar el equipo a la fuente de alimentaci??n, leer todas las instrucciones de instalaci??n.

2. Sobrecalentamiento

No se debe utilizar el equipo en un ??rea con una temperatura ambiente superior a la m??xima recomendada: 55??C(131??F). Adem??s, para garantizar una circulaci??n de aire adecuada, se debe dejar como m??nimo un espacio de 8 cm (3 pulgadas) alrededor de las aberturas de ventilaci??n.

3. Cuando hay rayos: peligro de descarga el??ctrica

No utilizar el equipo ni conectar o desconectar cables durante per??odos de actividad de rayos.

4. Instalaci??n de equipos

La instalaci??n, el reemplazo y el mantenimiento de este equipo estar??n a cargo ??nica- mente de personal capacitado y competente.

5. Eliminaci??n de equipos

La eliminaci??n definitiva de este equipo se debe efectuar conforme a todas las leyes y reglamentaciones nacionales.

6. C??digos el??ctricos locales y nacionales

Este equipo se debe instalar conforme a los c??digos el??ctricos locales y nacionales.