Owner???s Manual

Permanently Lubricated

Tank Mounted

AIR COMPRESSOR

Model No.

919.724120

???Safety Guidelines

???Assembly

???Operation

???Maintenance

???Service and Adjustments

???Troubleshooting

???Repair Parts

CAUTION: Read the Safety Guidelines

and All Instructions Carefully Before

Operating.

Sold by Sears Canada, Inc. Toronto, Ont. M5B 2B8

D24461 Rev. 5 6/25/02

TABLE OF CONTENTS

WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 SPECIFICATION CHART . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 SAFETY GUIDELINES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-8 GLOSSARY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 DUTY CYCLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 ASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11-12 OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13-15 MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 SERVICE AND ADJUSTMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . .17-18 STORAGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 TROUBLESHOOTING GUIDE . . . . . . . . . . . . . . . . . . . . . . . . . . . .19-21 AIR COMPRESSOR DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22 PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23 AIR COMPRESSOR PUMP DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . .24 PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 FRAN??AIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26-51

HOW TO ORDER REPAIR PARTS . . . . . . . . . . . . . . . . . . . .Back Cover

WARRANTY

FULL ONE YEAR WARRANTY ON AIR COMPRESSORS

If this air compressor fails due to a defect in material or workmanship within one year from the date of purchase, RETURN IT TO THE NEAREST SEARS

SERVICE CENTER THROUGHOUT CANADA AND SEARS WILL REPAIR IT,

FREE OF CHARGE.

If this air compressor is used for commercial or rental purposes, the warranty will apply for ninety days (90) from the date of purchase.

This Craftsman Air Compressor warranty gives you specific legal rights and you may have other rights which vary from province to province.

Sears Canada, Inc., Toronto, Ont. M5B 2B8

SAFETY GUIDELINES - DEFINITIONS

This manual contains information that is important for you to know and understand. This information relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS. To help you recognize this information, we use the symbols below. Please read the manual and pay attention to these sections.

IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS

IMPROPER OPERATION OR MAINTENANCE OF THIS PRODUCT COULD RESULT IN

SERIOUS INJURY AND PROPERTY DAMAGE. READ AND UNDERSTAND ALL

WARNINGS AND OPERATING INSTRUCTIONS BEFORE USING THIS EQUIPMENT.

Some dust created by power sanding, sawing, grinding, drilling, and other construction activities contains chemicals known (to the State of California) to

cause cancer, birth defects or other reproductive harm. Some example of these chemicals are:

???

???

???

lead from lead-based paints

crystalline silica from bricks and cement and other masonry products

arsenic and chromium from chemically-treated lumber

Your risk from these exposures varies, depending on how often you do this type of work. To reduce your exposure to these chemicals: work in a well ventilated area, and work with approved safety equipment, always wear MSHA/NIOSH approved, properly fitting face mask or respirator when using such tools.

When using air tools, basic safety precautions should always be followed to reduce the risk of of personal injury.

HAZARD

RISK OF EXPLOSION OR FIRE

HAZARD

RISK OF BURSTING

AIR TANK: THE FOLLOWING CONDITIONS COULD LEAD TO A WEAKENING OF THE

TANK, AND RESULT IN A VIOLENT TANK EXPLOSION AND COULD CAUSE

PROPERTY DAMAGE OR SERIOUS INJURY.

HAZARD

RISK FROM FLYING OBJECTS

HAZARD

RISK OF ELECTRICAL SHOCK

HAZARD

RISK TO BREATHING

HAZARD

RISK OF BURNS

HAZARD

RISK FROM MOVING PARTS

HAZARD

RISK OF PROPERTY DAMAGE WHEN TRANSPORTING COMPRESSOR

(Fire, Inhalation, Damage to Vehicle Surfaces)

GLOSSARY

Become familiar with these terms before operating the unit.

CFM: Cubic feet per minute.

SCFM: Standard cubic feet per minute; a unit of measure of air delivery.

PSIG: Pounds per square inch gauge; a unit of measure of pressure.

Code Certification: Products that bear one or more of the following marks: UL, CUL, ETL, CETL, have been evaluated by OSHA certified independent safety laboratories and meet the applicable Underwriters Laboratories Standards for Safety.

Cut-In Pressure: While the motor is off, air tank pressure drops as you continue to use your accessory.

When the tank pressure drops to a certain low level the motor will restart automatically. The low pressure at which the motor automatically restarts is called ???cut-in??? pressure.

Cut-Out Pressure: When an air compressor is turned on and begins to run, air pressure in the air tank begins to build. It builds to a certain high pressure before the motor automatically shuts off - protecting your air tank from pressure higher than its capacity. The high pressure at which the motor shuts off is called ???cut-out??? pressure.

Branch Circuit: Circuit carrying electricity from electrical panel to outlet.

ACCESSORIES

This unit is capable of powering the following Accessories. The accessories are available through the current Power and Hand Tool Catalog or full-line Sears stores.

DUTY CYCLE

Air compressors should be operated on not more than a 50% duty cycle. This means an air compressor that pumps air more than 50% of one hour is considered misuse, because

the air compressor is undersized for the required air demand. Maximum compressor pumping time per hour is 30 minutes.

ASSEMBLY

Contents of Carton

2 - Screws, #10-16 x 1.00

Tools Required for

Assembly

1 - 9/16??? socket or open end wrench

1 - 3/8??? socket

Installing Handles,

Wheels, and Molded Foot

Bumpers

The wheels and handle

do not provide adequate clearance, stability or support for pulling the unit up and down stairs or steps. The unit must be lifted, or pushed up a ramp.

1.Submerge handle grip into warm soapy water to make installation easier. Remove handle grip from soapy water and slide onto handle.

2.Slide handle through holes in compressor saddle onto tabs. Secure with screws, one on each side.

Compressor Saddle

Handle Screw

Tab

It will be necessary to brace or support

one side of the outfit when installing the wheels because the compressor will have a tendency to tip over.

3.Install one shoulder bolt and one nut for each wheel. Tighten securely. The outfit will sit level if the wheels are properly installed.

4.Clean and dry underside of air tank leg opposite wheels. Remove the protective strip from the adhesive backed molded foot bumpers. Attach the foot bumpers to the bottom of leg on each end. Press firmly into place.

Molded Foot Bumpers

INSTALLATION

HOW TO SET UP YOUR

UNIT

Location of the Air Compressor

Locate the air compressor in a clean, dry and well ventilated area. The air compressor should be located at least 12" away from the wall or other obstructions that will interfere with the flow of air. The air compressor pump and shroud are designed to allow for proper cooling. The ventilation openings on the compressor are necessary to maintain proper operating temperature. Do not place rags or other containers on or near these openings.

IMPORTANT: The outlet being used must be installed and grounded in accordance with all local codes and ordinances.

2.Make sure the outlet being used has the same configuration as the grounded plug. DO NOT USE AN ADAPTER. See illustration.

Plug

Grounded

Outlets

Grounding Pin

3.Inspect the plug and cord before each use. Do not use if there are signs of damage.

GROUNDING INSTRUCTIONS

RISK OF

ELECTRICAL SHOCK. In the event of a short circuit, grounding reduces the risk of shock by providing an escape wire for the electric current. This air compressor must be properly grounded.

The portable air compressor is equipped with a cord having a grounding wire with an appropriate grounding plug (see following illustrations). The plug must be used with an outlet that has been installed and grounded in accordance with all local codes and ordinances.

1.The cord set and plug with this unit contains a grounding pin. This plug MUST be used with a grounded outlet.

4.If these grounding instructions are not completely understood, or if in doubt as to whether the compressor is properly grounded, have the installation checked by a qualified electrician.

IMPROPER

GROUNDING CAN

RESULT IN ELECTRICAL SHOCK.

Do not modify the plug provided. If it does not fit the available outlet, a correct outlet should be installed by a qualified electrician.

Repairs to the cord set or plug MUST be made by a qualified electrician.

Extension Cords

Use extra air hose instead of an extension cord to avoid voltage drop and power loss to the motor, and to prevent overheating.

If an extension cord must be used, be sure it is:

???a 3-wire extension cord that has a 3-blade grounding plug, and a 3-slot receptacle that will accept the plug on the product

???in good condition

???no longer than 50 feet

???12 gauge (AWG) or larger. (Wire size increases as gauge number decreases. 10 AWG and 8 AWG may also be used. DO NOT USE 14 OR 16 AWG.)

Voltage and Circuit Protection

Refer to the Parts Manual for the voltage and minimum branch circuit requirements.

Certain air compressors can be operated on a 15 amp circuit if the following conditions are met.

1.Voltage supply through branch circuit is 15 amps.

2.Circuit is not used to supply any other electrical needs (lights, appliances, etc.).

3.Extension cords comply with specifications.

4.Circuit is equipped with a 15 amp circuit breaker or 15 amp time delay fuse. NOTE: If compressor is connected to a circuit protected by fuses, use only time delay fuses. Time delay fuses should be marked "D" in Canada and "T" in the US.

If any of the above conditions cannot be met, or if operation of the compressor repeatedly causes interruption of the power, it may be necessary to operate it from a 20 amp circuit. It is not necessary to change the cord set.

OPERATION

Know Your Air Compressor

READ THIS OWNER???S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference.

Description of Operation

Become familiar with these controls before operating the unit.

On/Auto/Off Switch: Turn this switch "ON" to provide automatic power to the pressure switch and "OFF" to remove power at the end of each use.

Pressure Switch: The pressure switch automatically starts the motor when the air tank pressure drops below the factory set ???cut-in??? pressure. It stops the motor when the air tank pressure reaches the factory set ???cut-out??? pressure.

Safety Valve: If the pressure switch does not shut off the air compressor at its ???cut-out??? pressure setting, the safety valve will protect against high pressure by ???popping out??? at its factory set pressure (slightly higher than the pressure switch ???cut-out??? setting).

Outlet Pressure Gauge: The outlet pressure gauge indicates the air pressure available at the outlet side of the regulator. This pressure is controlled by the regulator and is always less than or equal to the tank pressure.

Tank Pressure Gauge: The tank pressure gauge indicates the reserve air pressure in the tank.

Regulator: Controls the air pressure shown on the outlet pressure gauge. Pull the knob out and turn clockwise to increase pressure and counterclockwise to decrease pressure. When the desired pressure is reached push knob in to lock in place.

Universal Quick-Connect Body:

The universal quick-connect body accepts the three most popular styles of quick-connect plugs- Industrial, automotive (Tru-flate), and ARO. One hand push-to-connect operation makes connections simple and easy.

Drain Valve: The drain valve is located at the base of the air tank and is used to drain condensation at the end of each use.

Drain

Valve

Cooling System (not shown): This compressor contains an advanced design cooling system. At the heart of this cooling system is an engineered fan. It is perfectly normal for this fan to blow air through the vent holes in large amounts. You know that the cooling system is working when air is being expelled.

Air Compressor Pump (not shown):

Compresses air into the air tank. Working air is not available until the compressor has raised the air tank pressure above that required at the air outlet.

Check Valve: When the air compressor is operating, the check valve is "open", allowing compressed air to enter the air tank. When the air compressor reaches ???cut-out" pressure, the check valve "closes", allowing air pressure to remain inside the air tank.

Check Valve

How to Use Your Unit

How to Stop:

1.Set the On/Auto/Off lever to "OFF".

Before Starting

Break-in Procedure

Serious damage may result if the

following break-in instructions are not closely followed.

This procedure is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced.

1.Make sure the On/Auto/Off lever is in the "OFF" position.

NOTE: Pull coupler back until it clicks to prevent air from escaping through the quick connect.

2.Plug the power cord into the correct branch circuit receptacle. (Refer to Voltage and Circuit Protection paragraph in the Installation section of this manual.)

3.Open the drain valve fully (counter-clockwise) to permit air to escape and prevent air pressure build up in the air tank during the break-in period.

4.Move the On/Auto/Off lever to "ON/AUTO" position. The compressor will start.

5.Run the compressor for 15 minutes. Make sure the drain valve is open and there is minimal air pressure build-up in tank.

6.After 15 minutes, close the drain valve (clockwise). The air receiver will fill to "cut-out" pressure and the motor will stop.

The compressor is now ready for use.

Before Each Start-Up:

1.Place On/Auto/Off lever to "OFF" and close air regulator.

2.Pull regulator knob out, turn counter-clockwise until it stops. Push knob in to lock in place.

3.Attach hose and accessories. NOTE: The hose or accessory will require a quick connect plug if the air outlet is equipped with a quick connect socket.

Too much air pressure causes a

hazardous risk of bursting. Check the manufacturer???s maximum pressure rating for air tools and accessories. The regulator outlet pressure must never exceed the maximum pressure rating.

How to Start:

1.Turn the On/Auto/Off lever to "AUTO" and allow tank pressure to build. Motor will stop when tank pressure reaches "cut-out" pressure.

2.Pull the regulator knob out and turn clockwise to increase pressure. When the desired pressure is reached push knob in to lock in place. The compressor is ready for use.

NOTE: Always operate the air compressor in well-ventilated areas free of gasoline or other combustible vapors. If the compressor is being used to operate a sprayer DO NOT place near the spray area.

MAINTENANCE

Customer Responsibilities

Unit cycles automatically when

power is on. When performing maintenance, you may be exposed to voltage sources, compressed air, or moving parts. Personal injuries can occur. Before performing any maintenance or repair, disconnect power source from the compressor and bleed off all air pressure.

NOTE: See "Operation" section for the location of controls.

To Check Safety Valve

If the safety valve does not work

properly, over-pressurization may occur, causing air tank rupture or an explosion.

1.Before starting compressor, pull the ring on the safety valve to make sure that the safety valve operates freely. If the valve is stuck or does not operate smoothly, it must be replaced with the same type of valve.

To Drain Tank

1.Set the On/Auto/Off lever to "OFF".

2.Pull the regulator knob out and turn counter-clockwise to set the outlet pressure to zero.

3.Remove the air tool or accessory.

4.Pull ring on safety valve allowing air to bleed from the tank until tank pressure is approximately 20 psi. Release safety valve ring.

5.Drain water from air tank by opening drain valve (counter- clockwise) on bottom of tank.

Water will condense in the air

tank. If not drained, water will corrode and weaken the air tank causing a risk of air tank rupture.

6.After the water has been drained, close the drain valve (clockwise). The air compressor can now be stored.

NOTE: If drain valve is plugged, release all air pressure. The valve can then be removed, cleaned, the reinstalled.

SERVICE AND ADJUSTMENTS

Unit cycles automatically when

power is on. When doing Maintenance, you may be exposed to voltage sources, compressed air or moving parts. Personal injuries can occur. Before performing any Maintenance or repair, unplug the compressor and bleed off all air pressure.

ALL MAINTENANCE AND REPAIR

OPERATIONS NOT LISTED MUST

BE PERFORMED BY TRAINED

SERVICE TECHNICIAN.

To Replace or Clean Check Valve

1.Release all air pressure from air tank. See "To Drain Tank" in the Maintenance section.

2.Unplug outfit.

3.Loosen the nut on the outlet tube and move the outlet tube to the side.

Outlet Tube

Nut

Check

Valve

4.Unscrew the check valve (turn counterclockwise) using a socket wrench.

5.Make sure the valve disc moves freely inside the check valve and the spring holds the disc in the upper, closed position. The check valve may be cleaned with a solvent, such as paint and varnish remover.

Screwdriver

In open position nothing is visible.

In closed position disc is visible.

6.Apply sealant to the check valve threads. Reinstall the check valve (turn clockwise).

7.Replace the outlet tube and tighten the nut.

8.Perform the Break-in Procedure. See "Break-in Procedure" in the Operation section.

To Replace Regulator

1.Release all air pressure from air tank. See "To Drain Tank" in the Maintenance section.

2.Unplug outfit.

3.Using an adjustable wrench remove the gauges and quick connect from the regulator.

4.Remove the regulator.

5.Apply pipe sealant tape to the nipple on the standpipe.

6.Assemble the regulator and orient as shown.

NOTE: Arrow indicates flow of air. Make sure it is pointing in the direction of air flow.

Regulator

Arrow

7.Reapply pipe sealant to gauges and quick connect.

8.Reassemble gauges and quick connect. Orient gauges to read correctly. Tighten quick connect with wrench.

STORAGE

Before you store the air compressor, make sure you do the following:

1.Review the "Maintenance" section on the preceding pages and perform scheduled maintenance as necessary.

2.Set the On/Auto/Off lever to "OFF".

3.Turn the regulator counterclockwise and set the outlet pressure to zero.

4.Remove the air tool or accessory.

5.Pull ring on safety valve allowing air to bleed from the tank until tank pressure is approximately 20 psi. Release safety valve ring.

6.Drain water from air tank by opening drain valve on bottom of tank.

Water will condense in the air

tank. If not drained, water will corrode and weaken the air tank causing a risk of air tank rupture.

7.After the water has been drained, close the drain or drain valve.

NOTE: If drain valve is plugged, release all air pressure. The valve can then be removed, cleaned, then reinstalled.

8.Protect the electrical cord and air hose from damage (such as being stepped on or run over). Wind them loosely around the compressor handle. (If so equipped)

Store the air compressor in a clean and dry location.

TROUBLESHOOTING

Performing repairs may expose voltage sources, moving parts or compressed air sources, moving parts or

compressed air sources. Personal injury may occur. Prior to attempting any repairs, unplug the air compressor and bleed off all air tank air pressure.

TABLE DES MATI??RES

GARANTIE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 TABLEAU DES SP??CIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27

MESURES DE S??CURIT?? - D??FINITIONS . . . . . . . . . . . . . . . . . . . . . . . .27 MESURES DE S??CURIT?? IMPORTANTES . . . . . . . . . . . . . . . . . . . . .27-32

LEXIQUE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33 ACCESSOIRES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33 CYCLE DE SERVICE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33 ASSEMBLAGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35-36 UTILISATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37-39 ENTRETIEN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40 ENTRETIEN ET R??GLAGES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41-42 RANGEMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42 GUIDE DE D??PANNAGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43-45 SCH??MA DU COMPRESSEUR ?? AIR . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 LISTE DES PI??CES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47 SCH??MA - BLOC COMPRESSEUR . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48 LISTE DES PI??CES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 REMARQUE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50-51

POUR PLACER UNE COMMANDE DE PI??CES

DE RECHANGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Couverture arri??re

GARANTIE

GARANTIE COMPL??TE DE UN AN SUR LES COMPRESSEURS D???AIR

Ce compresseur d???air est garanti contre tout d??faut de fabrication pour une p??riode de un an, ?? compter de la date d???achat. Au cours de cette p??riode de garantie, SEARS S???ENGAGE ?? LE R??PARER SANS FRAIS. IL SUFFIT DE LE

RETOURNER AU CENTRE DE SERVICE APR??S-VENTE SEARS LE PLUS

PROCHE. LES CENTRES DE SERVICE APR??S-VENTE SONT R??PARTIS

DANS TOUT LE CANADA.

Cette garantie ne s???applique que pour une p??riode de quatre-vingt-dix (90) jours seulement, ?? compter de la date d???achat, sur un compresseur qui est utilis?? ?? des fins commerciales ou comme appareil de location

Cette garantie sur le compresseur d'air de Craftsman vous donne des droits particuliers. Il se peut que vous ayez d???autres droits qui varient d???une province ?? l???autre.

Sears Canada, Inc., Toronto, Ont. M5B 2B8

TABLEAU DES SP??CIFICATIONS

MESURES DE S??CURIT?? - D??FINITIONS

S??CURIT?? ET PR??VENTION DE PROBL??MES D?????QUIPEMENT. Afin de vous aider ?? identifier cette information, nous avons utilis?? des signes de danger plus bas. Veuillez lire attentivement ce guide en portant une attention particuli??re ?? ces sections.

CONSIGNES DE S??CURIT?? IMPORTANTES

CONSERVER CES DIRECTIVES

UN EMPLOI OU UN ENTRETIEN NON APPROPRI??S DE CE PRODUIT PEUT CAUSER

DES BLESSURES GRAVES ET DES DOMMAGES ?? LA PROPRI??T??. LIRE

ATTENTIVEMENT TOUS LES AVERTISSEMENTS ET LES DIRECTIVES D???UTILISATION

AVANT D???UTILISER CET APPAREIL.

La poussi??re produite par le pon??age ??lectrique le sciage, le meulage, le per??age et autres activit??s de construction peut

contenir des produits chimiques qui sont reconnus, par l'??tat de la Californie, de causer le cancer, les anomalies cong??nitales ou autres maux de reproduction. Ces produits chimiques comprennent, entre autres :

???le plomb provenant des peintures ?? base de plomb;

???la silice cristalline provenant de briques, de b??ton ou d'autres produits de ma??onnerie

???l'arsenic et le chrome provenant du bois de charpente trait?? chimiquement

Le risque d'exposition ?? ces produits d??pend de la fr??quence d'ex??cution de ce genre de travaux. Afin de r??duire l'exposition ?? ces produits chimiques, travaillez dans un endroit bien a??r?? et utilisez de l'??quipement de s??curit?? approuv??, portez toujours un masque facial ou respirateur homologu?? MSHA/NIOSH bien ajust?? lorsque vous utilisez de tels outils.

Lorsque vous utilisez un outil pneumatique, il faut toujours suivre les mesures de s??curit?? de base afin de r??duire le risque de blessures corporelles.

DANGER

RISQUE D???EXPLOSION OU D???INCENDIE

DANGER

RISQUE D?????CLATEMENT

R??SERVOIR D???AIR : LES CONDITIONS SUIVANTES PEUVENT AFFAIBLIR LES PAROIS DU

R??SERVOIR ET PROVOQUER UNE EXPLOSION VIOLENTE DU R??SERVOIR QUI RISQUE DE

CAUSER DES DOMMAGES ?? LA PROPRI??T?? OU DES BLESSURES GRAVES.

RISQUE

1.LE D??FAUT DE VIDANGER DE FA??ON

APPROPRI??E L???EAU CONDENS??E

DANS LE R??SERVOIR RISQUE DE

CAUSER LA ROUILLE ET

L???AMINCISSEMENT DES PAROIS EN

ACIER DU R??SERVOIR.

2.DES MODIFICATIONS OU TENTATIVES

DE R??PARATION FAITES SUR LE

R??SERVOIR.

3.DES MODIFICATIONS NON

AUTORIS??ES APPORT??ES ?? LA

SOUPAPE DE D??CHARGE, ?? LA

SOUPAPE DE S??RET?? OU ?? TOUTE

AUTRE COMPOSANTE QUI CONTR??LE

LA PRESSION DU R??SERVOIR.

4.DES VIBRATIONS EXCESSIVES

PEUVENT AFFAIBLIR LE R??SERVOIR

ET CAUSER UNE RUPTURE OU UNE

EXPLOSION.

FIXATIONS ET ACCESSOIRES :

LE FAIT D???EXC??DER LA PRESSION

NOMINALE DES OUTILS PNEUMATIQUES,

PISTOLETS PULV??RISATEURS,

ACCESSOIRES PNEUMATIQUES, PNEUS ET

AUTRES OBJETS GONFLABLES RISQUE DE

PROVOQUER L???EXPLOSION DE CES

DERNIERS ET LA PROJECTION DE PI??CES,

CE QUI RISQUE DE CAUSER DE GRAVES

BLESSURES.

PR??VENTION

PURGER LE R??SERVOIR QUOTIDIENNEMENT

OU APR??S CHAQUE UTILISATION. SI LE

R??SERVOIR ACCUSE UNE FUITE, LE

REMPLACER IMM??DIATEMENT PAR UN

NOUVEAU R??SERVOIR OU REMPLACER LE

COMPRESSEUR AU COMPLET.

NE JAMAIS PERFORER AVEC UNE

PERCEUSE, SOUDER OU FAIRE UNE

MODIFICATION QUELCONQUE AU

R??SERVOIR OU ?? SES ACCESSOIRES.

LE R??SERVOIR EST CON??U POUR SUBIR DES

PRESSIONS DE SERVICE PARTICULI??RES. NE

JAMAIS EFFECTUER DES R??GLAGES NI

SUBSTITUER DES PI??CES POUR MODIFIER

LES PRESSIONS DE SERVICE ??TABLIES ?? L???USINE.

POUR LE CONTR??LE ESSENTIEL DE LA

PRESSION D???AIR, IL FAUT POSER UN

R??GULATEUR DE PRESSION (S???IL N???EST PAS

D??J?? POS?? ET UN MANOM??TRE ?? LA

SORTIE D???AIR DU COM-PRESSEUR). SUIVRE

LES RECOMMANDATIONS DU FABRICANT DE

L?????QUIPEMENT ET NE JAMAIS EXC??DER LA

VALEUR NOMINALE DE PRESSION SP??CIFI??E

DES ACCESSOIRES. NE JAMAIS UTILISER LE

COMPRESSEUR POUR GONFLER DES

OBJETS ?? FAIBLE PRESSION, TELS QUE LES

JOUETS D???ENFANT, LES BALLONS DE

FOOTBALL OU DE BASKET-BALL, ETC.

DANGER

RISQUE DE PROJECTION D???OBJETS

DANGER

RISQUE DE CHOC ??LECTRIQUE

DANGER

RISQUE PAR INHALATION

DANGER

RISQUE DE BR??LURES

RISQUE

LE FAIT DE TOUCHER AUX SURFACES DE

M??TAL EXPOS??ES TELLES QUE LA T??TE DU

COMPRESSEUR OU LES TUBES DE SORTIE

PEUT CAUSER DE GRAVES BR??LURES ?? LA PEAU.

PR??VENTION

NE JAMAIS TOUCHER AUX PI??CES DE

M??TAL EXPOS??ES DU COMPRESSEUR

DURANT OU IMM??DIATEMENT APR??S LE

FONCTIONNEMENT. LE COMPRESSEUR

DEMEURE CHAUD PENDANT PLUSIEURS

MINUTES APR??S LE FONCTIONNEMENT.

NE PAS TENTER D???ATTEINDRE LES

COMPOSANTES DERRI??RE LES GARDES DE

PROTECTION ET NE PAS EFFECTUER DE

L???ENTRETIEN AVANT D???AVOIR LAISS??

REFROIDIR L???APPAREIL.

DANGER

RISQUE DE DOMMAGES ?? LA PROPRI??T?? PENDANT LE TRANSPORT

DU COMPRESSEUR

(incendie, inhalation, dommages aux surfaces du v??hicule)

DANGER

RISQUE D'UNE UTILISATION DANGEREUSE

LEXIQUE

Veuillez vous familiariser avec ces termes avant d'utiliser l'appareil.

CFM : pieds cubes par minute (pi3/min).

SCFM : pieds cubes par minute (pi3/min) standard. Une unit?? de mesure de d??bit d'air. PSIG: jauge indiquant le nombre de livres par pouce carr?? (lb/po2). Une unit?? de mesure de pression.

ASME : American Society of Mechanical Engineers. Fabriqu??, mis ?? l'essai, inspect?? et enregistr?? pour r??pondre aux normes de la ASME.

Codes de certification : Les produits portant une ou plusieurs des mentions suivantes (UL, CUL, ETL, CETL) ont ??t?? ??valu??s par des laboratoires ind??pendants de s??curit?? certifi??s par l'OSHA et r??pondent aux normes de s??curit?? applicables des Underwriters Laboratories.

Pression d'amor??age : Lorsque le moteur est arr??t??, la pression du r??servoir d'air s'abaisse

tandis qu'on continue d'utiliser l'accessoire. Quand la pression du r??servoir tombe ?? un niveau bas r??gl?? ?? l'usine, le moteur se remet automatiquement en marche. La basse pression ?? laquelle le moteur se remet automatiquement en marche s'appelle la "pression d'amor??age".

Pression de rupture : Lorsqu'on met un compresseur d'air en marche et qu'il commence ?? fonctionner, la pression d'air dans le r??servoir commence ?? s'accumuler. La pression monte et atteint un niveau ??lev?? r??gl?? ?? l'usine, avant que le moteur ne s'arr??te automatiquement, prot??geant ainsi le r??servoir d'air d'un taux de pression qui exc??derait sa capacit??. La haute pression ?? laquelle le moteur s'arr??te s'appelle la "pression de rupture".

Circuit de d??rivation : Le circuit acheminant l'??lectricit?? du tableau ??lectrique vers la prise murale.

ACCESSOIRES

Cet appareil peut alimenter les accessoires suivants. Les accessoires figurent dans le Catalogue actuel des outils ??lectriques et manuels et sont ??galement disponibles des magasins Sears vendant nos gammes compl??tes.

Accessoires

???Filtre en ligne

???Raccord de gonflage pour pneus

???Jeu de raccords ?? connexion rapide (diverses dimensions)

???R??gulateurs de pression d'air

???Dispositifs de lubrification ?? bruine d'huile

???Boyau d'air : 1/4 po, 3/8 po ou 1/2 po (diam. int.), diverses longueurs

Consultez le tableau de s??lection situ?? sur l'appareil pour choisir les outils qui peuvent ??tre aliment??s avec cet appareil.

CYCLE DE SERVICE

Les compresseurs d'air ne devraient pas avoir un cycle de service sup??rieur ?? 50%. Cela veut dire qu'un compresseur qui a pomp?? de l'air pendant plus de 50% d'une heure est consid??r?? comme avoir subi un mauvais usage parce que le

compresseur d'air n'est pas assez puissant pour r??pondre aux besoins de production d'air comprim??. Le temps d'utilisation maximum du compresseur est donc 30 minutes par heure.

MISE EN GARDE
MISE EN GARDE

ASSEMBLAGE

Contenu de la bo??te

1 - Compresseur d'air

2 - Roues

2 - Boulons ?? ??paulement, 3/8-16

2 - ??crous hexagonaux, 3/8-16

2 - Pare-chocs moul??s pour pieds

1 - Poign??e

1 - Prise de poign??e

2 - Vis, #10-16 x 1.00

Outils requis pourl'assemblage

1 - Cl?? ?? douille ou cl?? ouverte de 9/16 po

1 - Cl?? ?? douille de 3/8 po

Installation des poign??es, des roues et des pare-chocs moul??s pour pieds

Les roues et la poign??e n'offrent

pas assez de d??gagement, de stabilit?? ou de support pour tirer l'appareil en ascendant ou en descendant un escalier. Il faut soulever l'appareil ou le pousser sur une rampe.

1.Submergez la prise de poign??e dans de l'eau chaude savonneuse pour faciliter la pose. Retirez la prise de poign??e de l'eau savonneuse et glissez-la sur la poign??e.

2.Glissez la poign??e dans les trous de la selle du compresseur et placez les embouts sur les pattes. Fixez la poign??e en ins??rant une vis de chaque c??t??.

Selle du compresseur

Poign??e Vis

Patte

Il faut ??tayer ou supporter un c??t??

de l'ensemble lors de la pose des roues parce que le compresseur aura tendance de chavirer.

3.Ins??rez un boulon ?? ??paulement et un ??crou sur chaque roue et serrez-les fermement. L'ensemble sera de niveau si les roues sont pos??es de mani??re appropri??e.

4.Nettoyez et s??chez la surface inf??rieure de la jambe du r??servoir d'air situ??e au c??t?? oppos?? des roues. Enlevez la bande protectrice de la surface adh??sive des pare-chocs moul??s pour pieds. Attachez un pare- chocs sur la surface inf??rieure de chaque jambe. Pressez-les fermement en place.

Pare-chocs moul??s pour pieds

INSTALLATION

MONTAGE DE L'APPAREIL

Emplacement du compresseur d'air

Le compresseur d'air doit ??tre situ?? dans un endroit propre, sec et bien a??r??. Le compresseur d'air doit ??tre situ?? ?? une distance d'au moins 12 po du mur ou de toute autre obstruction qui pourrait nuire au d??bit d'air. La pompe et la t??le de protection du compresseur sont con??us pour permettre un refroidissement appropri??. Les ouvertures d'a??ration du compresseur sont n??cessaires pour maintenir la temp??rature de fonctionnement appropri??e. Ne placez pas de chiffons ou de contenants sur ou ?? proximit?? de ces ouvertures. Le filtre ?? air doit ??tre libre d'obstructions pouvant r??duire le d??bit d'air au compresseur d'air.

DIRECTIVES DE MISE ?? LA TERRE

RISQUE DE

CHOCS ??LECTRIQUES ! En cas de court-circuit, la mise ?? la terre r??duit le risque de choc en fournissant un fil de fuite pour le courant ??lectrique. Ce compresseur d'air doit ??tre ad??quatement mis ?? la terre.

Ce compresseur d'air portatif est dot?? d'un cordon muni d'un fil de mise ?? la terre et d'une fiche appropri??e de mise ?? la terre (voir l'illustration ci-dessous). La fiche doit ??tre ins??r??e dans une prise de courant install??e et mise ?? la terre conform??ment ?? tous les codes et ordonnances ??lectriques locaux.

1.Le cordon fourni avec cet appareil comprend une fiche avec broche de mise ?? la terre. La fiche DOIT ??tre ins??r??e dans une prise de courant mise ?? la terre.

IMPORTANT: La prise de courant utilis??e doit ??tre install??e et mise ?? la terre conform??ment ?? tous les codes et ordonnances ??lectriques locaux.

2.Assurez-vous que la prise de courant utilis??e a la m??me configuration que la fiche de mise ?? la terre. NE PAS UTILISER UN ADAPTATEUR. Voir l'illustration.

Fiche

Prises de courant mises ?? la terre

Broche de mise ?? la terre

3.Inspectez la fiche et le cordon avant chaque utilisation. Ne pas les utiliser s'il y a des signes de dommages.

4.Si vous ne comprenez pas tout ?? fait ces directives de mise ?? la terre, ou s'il y a des doutes que le compresseur soit mis ?? la terre de mani??re appropri??e, faire v??rifier l'installation par un ??lectricien qualifi??.

UNE MISE ?? LA TERRE

INAPPROPRI??E PEUT

ENTRA??NER DES CHOCS ??LECTRIQUES.

Ne modifiez pas la fiche fournie. Si elle ne convient pas ?? la prise de courant disponible, une prise appropri??e doit ??tre install??e par un ??lectricien qualifi??.

Toute r??paration du cordon ou de la fiche DOIT ??tre effectu??e par un ??lectricien qualifi??

Rallonges

Utilisez un boyau d'air suppl??mentaire au lieu d'une rallonge pour ??viter une chute de tension, une perte de puissance et la surchauffe du moteur.

Si une rallonge doit ??tre utilis??e, s'assurer :

???d'utiliser une rallonge ?? trois fils, munie d'une fiche ?? trois lames avec mise ?? la terre et une prise de courant ?? trois fentes qui accepte la fiche de la rallonge;

???qu'elle est en bon ??tat;

???qu'elle n'exc??de pas 50 pi (15,5 m);

???que les fils sont d'un calibre minimum de 12 AWG. (La grosseur du fil augmente comme le num??ro de calibre diminue. Les fils de calibre 10 AWG et 8 AWG peuvent ??galement ??tre utilis??s. NE PAS UTILISER UN FIL DE CALIBRE 14 OU 16 AWG.)

Protection contre la surtension et

protection du circuit

Consulter le Guide des pi??ces pour conna??tre les exigences minimums concernant la tension et le circuit de d??rivation.

Certains mod??les de compresseur d'air peuvent fonctionner sur un circuit de 15 amp??res si les conditions suivantes sont satisfaites :

1.la tension d'alimentation au circuit de d??rivation est de 15 A;

2.le circuit n'est pas utilis?? pour alimenter d'autres dispositifs ??lectriques (lumi??res, appareils ??lectriques, etc.);

3.les rallonges sont conformes aux sp??cifications;

4.le circuit est muni d'un coupe-circuit de 15 A ou d'un fusible retard?? de 15 A. REMARQUE : Si un compresseur est reli?? ?? un circuit prot??g?? par des fusibles, n'utilisez que des fusibles ?? retardement. Les fusibles ?? retardement portent un " D " au Canada et un " T " aux ??tats-Unis.

Si une des conditions ci-dessus ne peut ??tre satisfaite, ou si l'utilisation du compresseur entra??ne continuellement une panne de courant, il sera peut ??tre n??cessaire de brancher le compresseur sur un circuit de 20 amp??res. Il n'est pas n??cessaire de remplacer le cordon dans un tel cas.

UTILISATION

Familiarisez-vous avec votre compresseur d'air

LISEZ CE GUIDE DE L'UTILISATEUR ET TOUTES LES MESURES DE S??CURIT?? AVANT D'UTILISER CET APPAREIL. Comparez les illustrations ?? votre appareil pour vous familiariser avec l'emplacement des commandes et boutons de r??glage. Conservez ce guide pour r??f??rences ult??rieures.

Interrupteur

"On/Auto/Off"Manostat

Soupape de s??ret??

Corps universel ?? connexion rapide

Description du fonctionnement

Familiarisez-vous avec ces commandes avant d'utiliser l'appareil.

Interrupteur marche/automatique/arr??t "On/Auto/Off": Placez cet interrupteur ?? la position "ON" pour alimenter le manostat et ?? la position "OFF" pour couper le courant apr??s chaque utilisation.

Manostat : Le manostat d??marre automatiquement le moteur lorsque la pression dans le r??servoir d'air tombe ?? une valeur inf??rieure ?? la "pression d'amor??age" r??gl??e ?? l'usine. Il arr??te le moteur lorsque la pression dans le r??servoir d'air atteint la "pression de rupture" r??gl??e ?? l'usine.

Soupape de s??ret?? : Si le manostat n'arr??te pas le compresseur d'air lorsque la "pression de rupture" est atteinte, la soupape de s??ret?? prot??ge contre toute surpression en "sautant" ?? la valeur de pression ??tablie ?? l'usine (une pression l??g??rement sup??rieure ?? la "pression de rupture" ??tablie pour le manostat.

Manom??tre de sortie : Le manom??tre de sortie indique la pression d'air disponible ?? la sortie du r??gulateur. Cette pression est contr??l??e par le r??gulateur et est toujours inf??rieure ?? ou ??gale ?? la pression du r??servoir.

Manom??tre du r??servoir : Le manom??tre du r??servoir indique la pression d'air en r??serve dans le r??servoir.

R??gulateur : Le r??gulateur contr??le la pression d'air indiqu?? sur le manom??tre de sortie. Tirez le bouton et tournez-le dans le sens des aiguilles d'une montre pour augmenter la pression et dans le sens contraire pour r??duire la pression. Une fois que la pression d??sir??e est atteinte, poussez le bouton pour le verrouiller.

Corps universel ?? connexion rapide : Le corps universel ?? connexion rapide accepte les trois styles les plus en demande de fiches ?? connexion rapide, c'est-??-dire, industriel, automobile (Tru- flate) et ARO. Le raccordement est simple et rapide et s'accomplit par une simple pouss??e d'une seule main.

Robinet de vidange :

Le robinet de vidange est situ?? ?? la base du r??servoir d'air et est utilis?? pour vidanger la condensation apr??s chaque utilisation.

Robinet de vidange

Syst??me de refroidissement (non illustr??) :

Ce compresseur d'air offre un syst??me de refroidissement de pointe. Le c??ur de ce syst??me de refroidissement et un ventilateur. Il est tout ?? fait normal que ce ventilateur souffle une grande quantit?? d'air ?? travers les trous d'a??ration. L'expulsion d'air indique que le syst??me de refroidissement est en fonction.

Pompe du compresseur d'air (non illustr??e) :

La pompe comprime l'air pour le forcer dans le r??servoir d'air. L'air n'est pas disponible pour travailler avant que le compresseur n'ait ??lev?? la pression du r??servoir d'air au niveau requis ?? la sortie d'air.

Soupape de retenue : Lorsque le compresseur fonctionne, la soupape de retenue est "ouverte", permettant ?? l'air comprim?? d'entrer dans le r??servoir d'air. Quand le compresseur d'air atteint la "pression de rupture", la soupape de retenue "se ferme", permettant ?? l'air pressuris?? de demeurer ?? l'int??rieur du r??servoir d'air.

Soupape de retenue

Utilisation de l'appareil

Arr??t de l'appareil :

1.R??glez le levier marche/automatique/ arr??t "On/Auto/Off" ?? la position d'arr??t "OFF".

Avant le d??marrage

Proc??dures de rodage

Le compresseur

d'air peut subir d'importants dommages si les proc??dures de rodage ne sont pas suivies ?? la lettre.

Cette proc??dure doit ??tre ex??cut??e avant d'utiliser le compresseur d'air pour la premi??re fois et apr??s le remplacement de la soupape de retenue ou de la pompe compl??te du compresseur.

1.Assurez-vous que le levier marche/automatique/arr??t "On/Auto/Off" est en position d'arr??t "OFF".

REMARQUE: Tirez le raccord vers l'arri??re jusqu'?? ce qu'il s'enclenche afin d'emp??cher la fuite d'air du raccord ?? connexion rapide.

2.Branchez le cordon d'alimentation dans la prise de courant du circuit de d??rivation appropri??. (Consultez le paragraphe sur la protection contre la surtension et la protection du circuit de la section sur l'installation de ce guide.)

3.Ouvrez compl??tement le robinet de vidange (en tournant dans le sens contraire des aiguilles d'une montre) afin de permettre ?? l'air de sortir et pour emp??cher une accumulation de pression dans le r??servoir d'air lors de la p??riode de rodage.

4.Placez le levier "On/Auto/Off" ?? la position "ON/AUTO". Le compresseur se mettra en marche.

5.Faire fonctionner le compresseur pendant 15 minutes. Assurez-vous que le robinet de vidange est ouvert et que la pression d'air accumul??e dans le r??servoir est minimale.

6.Apr??s 15 minutes, fermez le robinet de vidange (en tournant dans le sens des aiguilles d'une montre). Le r??servoir d'air se remplira jusqu'?? ce que la "pression de rupture" soit atteinte et le moteur s'arr??tera ensuite.

Le compresseur d'air est maintenant pr??t pour l'utilisation.

Avant chaque mise en marche :

1.Placez le levier "On/Auto/Off" ?? la position "OFF".

2.Tirez le bouton du r??gulateur et tournez-le dans le sens contraire des aiguilles d'une montre jusqu'?? ce qu'il s'arr??te. Poussez le bouton pour le verrouiller.

3.Raccordez le boyau et les accessoires. REMARQUE : Le boyau ou l'accessoire doit ??tre muni d'une fiche ?? connexion rapide si la sortie d'air est ??quip??e d'une douille ?? connexion rapide.

Une pression d'air trop

??lev??e conduit ?? un risque dangereux d'??clatement. V??rifiez la pression nominale maximum du fabricant pour tous les outils pneumatiques et accessoires utilis??s. La pression de sortie du r??gulateur ne doit jamais exc??der la pression nominale maximum.

Mise en marche :

1.Placez le levier "On/Auto/Off" ?? la position "AUTO" et attendez jusqu'?? ce que la pression augmente. Le moteur s'arr??tera lorsque la pression dans le r??servoir atteint la "pression de rupture".

2.Tirez le bouton du r??gulateur et tournez-le dans le sens des aiguilles d'une montre pour augmenter la pression. Une fois que la pression d??sir??e est atteinte, poussez le bouton pour le verrouiller. Le compresseur d'air est maintenant pr??t pour l'utilisation.

REMARQUE : Utilisez toujours le compresseur d'air dans une r??gion bien a??r??e, sans vapeurs d'essence ni autres vapeurs combustibles. Si le compresseur est utilis?? avec un vaporisateur, NE PAS placer le compresseur pr??s de la r??gion de vaporisation.

ENTRETIEN

Responsabilit??s du client

L'appareil fonctionne

automatiquement en cycles lorsqu'il est sous tension. En effectuant l'entretien, vous pouvez ??tre expos?? aux sources de tension, ?? l'air comprim?? ou aux pi??ces mobiles et subir ainsi des blessures corporelles. Avant d'entreprendre tout entretien ou r??paration, d??branchez l'appareil et purgez tout l'air pressuris?? du r??servoir.

REMARQUE : Consultez la section "Utilisation" pour conna??tre l'emplacement des commandes.

V??rification de la soupape de s??ret??

Si la soupape de s??ret?? ne

fonctionne pas correctement, une surpression pourrait avoir lieu et causer une rupture ou une explosion du r??servoir ?? air.

1.Avant de mettre en marche le compresseur, tirez sur l'anneau de la soupape de s??ret?? pour vous assurer que la soupape fonctionne librement. Si la soupape est coinc??e ou qu'elle ne bouge pas librement, elle doit ??tre remplac??e par une autre soupape du m??me type.

Vidange du r??servoir

1.R??glez le levier marche/automatique/arr??t "On/Auto/Off" ?? la position d'arr??t "OFF".

2.Tirez le bouton du r??gulateur vers l'ext??rieur et tournez dans le sens contraire des aiguilles d'une montre pour r??gler la pression de sortie ?? z??ro.

3.Enlevez l'outil pneumatique ou l'accessoire.

4.Tirez l'anneau de la soupape de s??ret?? pour permettre ?? l'air de purger du r??servoir jusqu'?? ce que la pression dans le r??servoir se situe ?? environ 20 lb/po2. Rel??chez l'anneau de la soupape de s??ret??.

5.Vidangez l'eau du r??servoir en ouvrant le robinet de vidange. (Tournez dans le sens contraire des aiguilles d'une montre) situ?? en bas du r??servoir.

L'eau dans le r??servoir d'air

peut condenser. Si l'eau n'est pas vidang??e, cela risque de corroder et d'affaiblir le r??servoir d'air, produisant ainsi un risque de rupture du r??servoir d'air.

6.Une fois la vidange de l'eau termin??e, fermez le robinet de vidange (tournez dans le sens des aiguilles d'une montre). Le compresseur d'air peut maintenant ??tre rang??.

REMARQUE : Si le robinet de vidange est engorg??, lib??rez tout l'air pressuris??. Le robinet de vidange peut alors ??tre enlev??, nettoy?? et r??install??.

ENTRETIEN ET R??GLAGES

Le compresseur d'air fonctionne automatiquement lorsqu'il est sous tension.

En effectuant l'entretien, vous pourriez ??tre expos?? aux sources de tension, ?? de l'air comprim?? ou aux pi??ces en mouvement et subir ainsi des blessures corporelles. Avant de proc??der ?? tout entretien ou r??paration, d??branchez le compresseur et purgez tout l'air pressuris??.

TOUS LES SERVICES D'ENTRETIEN NE

FIGURANT PAS ICI DOIVENT ??TRE

EX??CUT??S PAR UN TECHNICIEN

QUALIFI??.

Remplacement ou nettoyage de la soupape de retenue

1.D??chargez tout l'air pressuris?? du r??servoir d'air. Voir la partie intitul??e "Vidange du r??servoir" de la section sur l'entretien.

2.D??branchez le compresseur d'air.

3.Desserrez l'??crou sur le tube de sortie et mettez le tube de c??t??.

Tube de sortie

??crou

Soupape de retenue

4.?? l'aide d'une cl?? ?? douille, d??vissez la soupape de retenue (en tournant dans le sens contraire des aiguilles d'une montre).

5.Assurez-vous que le disque de soupape se d??place librement ?? l'int??rieur de la soupape de retenue et que la tension du ressort retient le disque en position ??lev??e et ferm??e. La soupape de retenue peut ??tre nettoy??e ?? l'aide d'un solvant, tel qu'un d??capant ?? peinture et vernis.

Tournevis

En position ouverte, rien n'est visible

En position ferm??e, le disque est visible

6.Appliquez un produit d'??tanch??it?? sur les filets de la soupape. R??installer la soupape de retenue (en tournant dans le sens des aiguilles d'une montre).

7.Replacez le tube de sortie et resserrez l'??crou.

8.Effectuez la proc??dure de rodage. Voir la partie intitul??e "Proc??dures de rodage" de la section sur l'utilisation.

Remplacement du r??gulateur

1.D??chargez tout l'air pressuris?? du r??servoir d'air. Voir la partie intitul??e "Vidange du r??servoir" de la section sur l'entretien.

2.D??branchez le compresseur d'air.

3.?? l'aide d'une cl?? r??glable, retirez du r??gulateur le manom??tre de sortie et le raccord ?? connexion rapide (si compris).

4.Retirez le r??gulateur.

5.Appliquez du ruban d'??tanch??it?? sur l'embout du tuyau.

6.Assemblez le r??gulateur et orientez-le tel qu'illustr??.

REMARQUE : La fl??che indique le sens du d??bit d'air. Assurez-vous qu'elle est dirig??e dans la direction du d??bit d'air.

R??gulateur

Fl??che

7.Appliquez un produit d'??tanch??it?? au manom??tre de

sortie et au raccord ?? connexion rapide.

8.Assemblez le manom??tre de sortie et le raccord ??

connexion rapide. Orientez le manom??tre de sortie de fa??on ?? ce qu'il indique la pression correcte. Serrez le raccord ?? l'aide d'une cl??.

RANGEMENT

Avant de ranger le compresseur d'air, effectuez les ??tapes

suivantes :

1.Revoyez la section intitul??e "Entretien" des pages pr??c??dentes et ex??cutez l'entretien requis.

2.Placez le levier "On/Auto/Off" ?? la position "OFF".

3.Tournez le r??gulateur dans le sens contraire des aiguilles d'une montre et r??glez la pression de sortie ?? z??ro.

4.D??branchez l'outil pneumatique ou l'accessoire.

5.Tirez l'anneau de la soupape de s??ret?? pour purger l'air du r??servoir jusqu'?? ce que la pression dans le r??servoir soit d'environ 20 lb/po2. Rel??chez l'anneau de la soupape de s??ret??.

6.Vidangez l'eau du r??servoir d'air en ouvrant le robinet de vidange situ?? en bas du r??servoir.

L'eau dans le r??servoir

d'air peut condenser. Si le r??servoir n'est pas vidang??, l'eau corrodera et affaiblira les parois du r??servoir d'air, causant ainsi un risque d'??clatement du r??servoir.

7.Une fois la vidange de l'eau termin??e, fermez le robinet de vidange.

REMARQUE : Si le robinet de vidange est engorg??, lib??rez tout l'air pressuris??. Le robinet de vidange peut alors ??tre enlev??, nettoy?? et r??install??.

8.Prot??gez le cordon ??lectrique et le boyau d'air contre tout dommage (de fa??on ?? ce qu'ils ne soient pas coinc??s ou ??cras??s). Enroulez-les, sans contrainte, autour de la poign??e du compresseur d'air (le cas ??ch??ant).

Rangez le compresseur d'air dans un endroit propre et sec.

D??PANNAGE

En effectuant des r??parations au compresseur, il se peut que vous soyez expos?? aux sources de tension, aux

pi??ces mobiles ou aux sources d'air comprim?? qui risquent de causer des blessures corporelles. D??branchez le compresseur et purgez l'air pressuris?? du r??servoir avant d'entamer toute r??paration.

Connexions ??lectriques desserr??es. V??rifiez les connexions de c??blage dans la bo??te ?? bornes.

REMARQUE

REMARQUE

Get it fixed, at your home or ours!

Just Call:

1-800-4-MY-HOME??

(1-800-469-4663)

24 hours a day, 7 days a week

For the repair of major brand appliances in your own home??? no matter who made it, no matter who sold it!

For your nearest Sears Parts and Service location,

to bring in products like vacuums, lawn equipment and electronics.

For Sears Parts & Service, to order the replacement parts, accessories and owner???s manuals that you need to do-it-yourself.

www.sears.ca

To purchase or inquire about a Sears Maintenance Agreement, call:

1-800-361-6665

9 a.m. ??? 8 p.m. EST, Mon. ??? Fri., 4 p.m. Sat.

Pour service en fran??ais:

1-800-LE-FOYERMC

(1-800-533-6937)

www.sears.ca

HomeCentral??