???2001 Chevrolet Camaro
General Motors
Chevrolet; Camaro
Pontiac; Firebird
* PLEASE READ THIS FIRST *
WARNING: To avoid injury from accidental air bag deployment, read and carefully follow all SERVICE PRECAUTIONS and DISABLING & ACTIVATING AIR BAG SYSTEM procedures in AIR BAG RESTRAINT SYSTEM article in ACCESSORIES/SAFETY EQUIPMENT section.
SPECIFICATIONS
SPECIFICATIONS
???????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????
(1)- Use PAG Refrigerant Oil (Part No. 12345923).
(2)- Measured at ambient temperature of
with more than 50 percent relative humidity.
???????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????
DESCRIPTION
The manual
OPERATION
Several mode settings are available on the
OFF
No blower and A/C operation in this position. With vehicle moving forward, a slight amount of air will enter passenger compartment.
MAX
Maximum cooling is provided in this setting. Conditioned air is distributed through dash registers. This is the only mode in which
some of the air is recirculated through the A/C system.
A/C
Conditioned air is directed through dash registers.
Conditioned air is directed through dash registers and floor outlets. A small amount of air is directed to defrost outlets.
Vent
Compressor does not operate in this setting. Outside air is delivered through dash registers.
Heater
Compressor does not operate in this setting. Outside air is heated and distributed as follows: about 80 percent to floor and 20 percent to windshield and side windows.
Defrost
In defrost position, air is distributed to windshield.
Defrost Blend
In defrost blend position, air is distributed to floor, windshield and side windows.
Fig. 1: Identifying Control Panel Settings (Typical) Courtesy of General Motors Corp.
ADJUSTMENTS
TEMPERATURE CONTROL CABLE
1)Remove right instrument panel sound insulator. Remove temperature control cable from heater housing. Move temperature control knob from full cold to full hot setting. If cable binds or pulley does not rotate freely, replace cable. Set temperature control knob to detent position halfway between full cold and full hot setting.
2)If control cable pulley is offset by
Fig. 2: Adjusting Temperature Control Cable
Courtesy of General Motors Corp.
TROUBLE SHOOTING
NOTE: For additional trouble shooting information, see MANUAL
BLOWER MOTOR
1)If blower does not operate, check HVAC fuse
2)Ensure ground connectors located near left or right "A" pillar, bolted to instrument panel mounting stud behind kick panel are clean and tight. Check for a broken or partially broken wire inside of insulation which could cause system malfunction but prove good in a continuity/voltage check with system disconnected. Check for proper installation of aftermarket electronic equipment.
SYSTEM TESTS
WARNING: To avoid injury from accidental air bag deployment, read and carefully follow all SERVICE PRECAUTIONS and DISABLING & ACTIVATING AIR BAG SYSTEM procedures in AIR BAG SYSTEM SAFETY article in GENERAL SERVICING.
A/C SYSTEM PERFORMANCE
1)Rotate temperature control knob from full cold to full hot and back to full cold. Listen for temperature valve to seat in both full hot and full cold position. If temperature valve seats in both positions, go to next step. If temperature valve does not seat in both positions, go to step 4).
2)Park vehicle out of direct sunlight. Close doors and windows. Open driver???s window
3)Observe A/C compressor. If compressor engages, go to next step. If compressor does not engage, see A/C COMPRESSOR CLUTCH CONTROLS - ALL MODELS article.
4)Check cooling fan operation. If both cooling fans are operating, go to next step. If both cooling fans are not operating, see ELECTRIC COOLING FANS - ALL MODELS article.
5)Connect A/C manifold gauge set. Place thermometer at instrument panel center vent. Set temperature control to maximum cold, maximum A/C, and blower to high speed. Run engine at idle for 2 minutes. Note
Ensure system is operating within specified range. See A/C SYSTEM PERFORMANCE PRESSURE SPECIFICATIONS (2000 MODELS) and
A/C SYSTEM PERFORMANCE TEMPERATURE SPECIFICATIONS (2000 MODELS) tables. Also see
A/C SYSTEM PERFORMANCE PRESSURE SPECIFICATIONS (2001 MODELS) and
A/C SYSTEM PERFORMANCE TEMPERATURE SPECIFICATIONS (2001 MODELS) .
6)If system is operating within specified range, system is okay. If system is not operating within specified range, check Variable Displacement Orifice Tube (VDOT) system. See MANUAL A/C- HEATER SYSTEMS - TROUBLE SHOOTING article.
A/C SYSTEM PERFORMANCE PRESSURE SPECIFICATIONS (2000 MODELS)
???????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????
(1)- With relative humidity at less than 50 percent.
(2)- With relative humidity at more than 50 percent.
(3)- With relative humidity at less than 40 percent.
(4)- With relative humidity at more than 40 percent.
(5)- With relative humidity at less than 20 percent.
(6)- With relative humidity at more than 20 percent.
???????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????
A/C SYSTEM PERFORMANCE TEMPERATURE SPECIFICATIONS (2000 MODELS)
???????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????
(1)- With relative humidity at less than 50 percent.
(2)- With relative humidity at more than 50 percent.
(3)- With relative humidity at less than 40 percent.
(4)- With relative humidity at more than 40 percent.
(5)- With relative humidity at less than 20 percent.
(6)- With relative humidity at more than 20 percent.
???????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????
A/C SYSTEM PERFORMANCE PRESSURE SPECIFICATIONS (2001 MODELS)
???????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????
(1)- With relative humidity at
(2)- With relative humidity at more than 40 percent.
(3)- With relative humidity at more than 60 percent.
(4)- With relative humidity at more than 30 percent.
(5)- With relative humidity at more than 40 percent.
(6)- With relative humidity at more than 20 percent.
(7)- With relative humidity at less than 30 percent.
???????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????
A/C SYSTEM PERFORMANCE TEMPERATURE SPECIFICATIONS (2001 MODELS)
???????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????
(1)- With relative humidity at less than 50 percent.
(2)- With relative humidity at more than 50 percent.
(3)- With relative humidity at less than 40 percent.
(4)- With relative humidity at more than 40 percent.
(5)- With relative humidity at less than 20 percent.
(6)- With relative humidity at more than 20 percent.
???????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????
DIAGNOSTIC SYSTEM TEST
1)Connect scan tool to Data Link Connector (DLC). DLC is located under instrument panel, near steering column. If scan tool powers up, go to next step. If scan tool does not power up, go to appropriate BODY CONTROL MODULES article in ACCESSORIES & EQUIPMENT.
2)Turn ignition switch to ON position. Attempt to establish communications with
3)Following scan tool manufacturer???s instructions, select DISPLAY DTCs function for
4)If scan tool displays any DTCs beginning with "U", go to appropriate BODY CONTROL MODULES article in ACCESSORIES & EQUIPMENT. If no DTCs beginning with "U" are displayed, go to next step.
5)If scan tool displays any DTCs beginning with "B", go to appropriate BODY CONTROL MODULES article in ACCESSORIES & EQUIPMENT. If no DTCs beginning with "B" are displayed, go to next step.
6)If scan tool displays any DTCs beginning with "P", go to appropriate
BLOWER MOTOR ALWAYS ON
2000 Models
1)Perform DIAGNOSTIC SYSTEM TEST. Go to next step.
2)Turn ignition switch to OFF position. Disconnect blower motor relay. Using test light connected to ground, probe blower motor relay harness connector terminal A1 (Orange wire). If test light illuminates, go to next step. If test light does not illuminate, go to step 4).
3)Repair short to battery voltage in Orange wire between blower motor relay harness connector terminal A1 and blower motor switch harness connector C1 terminal "B" located at
4)Using test light connected to ground, probe blower motor
relay harness connector terminal B2 (Dark Blue wire). If test light illuminates, go to next step. If test light does not illuminate, go to step 6).
5)Repair short to battery voltage in Dark Blue wire between blower motor relay harness connector terminal B2 and blower motor resistor harness connector terminal "C". After repair, go to step 9).
6)Using test light connected to ground, probe blower motor relay harness connector terminal C1 (Purple wire). If test light illuminates, go to next step. If test light does not illuminate, go to step 8).
7)Repair short to battery voltage in Purple wire between blower motor relay harness connector terminal C1 and blower motor harness connector terminal "B". After repair, go to step 9).
8)Replace blower motor relay. After repair, go to next step.
9)Operate blower system to verify repair. If blower motor operates normally, repair is complete. If blower motor is still inoperative, return to step 2).
2001 Models
1)Perform DIAGNOSTIC SYSTEM TEST. Go to next step.
2)Turn ignition switch to ON position. Set mode switch in OFF position. If blower motor is off, problem is intermittent. Check for faulty wiring or poor connections. Repair or replace as necessary. After repair, go to step 14). If no problem is found, go to next step.
3)Turn ignition switch to OFF position. Disconnect blower motor relay. Turn ignition switch to ON position. If blower motor does not operate, go to next step. If blower motor operates, go to 11).
4)Ensure mode switch is in OFF position. Set blower speed switch at lowest speed position. Using test light connected to ground, probe blower motor relay harness connector terminal B2. If test light illuminates, go to next step. If test light does not illuminate, go to step 6).
5)Check Orange wire between blower motor switch harness connector C1 terminal "B" and blower motor relay harness connector terminal B2 for short to voltage. Repair Orange wire as necessary. After repair, go to step 14). If wire is okay, go to step 10).
6)Using test light connected to ground, probe blower motor relay harness connector terminal B2 (Dark Blue wire). If test light illuminates, go to next step. If test light does not illuminate, go to step 9).
7)Check Dark Blue wire between blower motor relay harness connector terminal B2 and blower motor resistor harness connector terminal "C" for short to voltage. Repair Dark Blue wire as necessary. After repair, go to step 14). If wire is okay, go to next step.
8)Check Yellow, Tan and Light Blue wires for short to voltage between blower motor switch harness connector C1 at
9)Check for poor connections or connector damage at blower motor relay harness connectors. Repair or replace as necessary. After repair, go to step 14). If connections are okay, go to step 12).
10)Check for poor connections or connector damage at A/C- heater control panel harness connectors. Repair or replace as necessary. After repair, go to step 14). If connections are okay, go to step 13).
11)Repair short to voltage in Purple wire between blower motor harness connector terminal "B" and blower motor relay harness connector terminal C1. After repair, go to step 14).
12)Replace blower motor relay. After repair, go to step 14).
13)Replace
14) Operate blower system to verify repair. If blower motor operates normally, repair is complete. If blower motor is still inoperative, return to step 2).
BLOWER MOTOR INOPERATIVE IN HIGH SPEED
2000 Models
1)Perform DIAGNOSTIC SYSTEM TEST. Go to next step.
2)Set mode switch in VENT position. Set blower motor switch in highest speed position. Using test light connected to ground, backprobe
3)Using test light connected to ground, probe blower motor relay harness connector terminal A1 (Orange wire). If test light illuminates, go to step 6). If test light does not illuminate, go to step 7).
4)Check for poor connection or connector damage at A/C- heater control panel harness connector C1. See WIRING DIAGRAMS. Repair or replace as necessary. After repair, go to step 13). If connections are okay, go to next step.
5)Replace blower motor switch. See BLOWER MOTOR SWITCH under REMOVAL & INSTALLATION. After repair, go to step 13).
6)Connect test light between blower motor relay harness connector terminals A1 (Orange wire) and C2 (Black wire). If test light illuminates, go to step 8). If test light does not illuminate, go to step 9).
7)Repair open or poor connection in Orange wire between blower motor relay harness connector terminal A1 and blower motor resistor harness connector terminal "C". After repair, go to step 13).
8)Connect test light between blower motor relay harness connector terminals A2 (Red wire) and C2 (Black wire). If test light illuminates, go to step 10). If test light does not illuminate, go to step 12).
9)Repair open or poor connection in Black wire between blower motor relay harness connector terminal C2 and ground. After repair, go to step 13).
10)Check for poor connections or connector damage at blower motor relay harness connector. Repair or replace as necessary. After repair, go to step 13). If connections are okay, go to next step.
11)Replace blower motor relay. After repair, go to step 13).
12)Repair open or poor connection in Red wire between blower motor relay harness connector terminal A2 and I/P
13)Operate blower system to verify repair. If blower motor operates normally, repair is complete. If blower motor is still inoperative in high speed, return to step 3).
BLOWER MOTOR INOPERATIVE
2000 Models
1)Perform DIAGNOSTIC SYSTEM TEST. Go to next step.
2)Turn ignition switch to ON position. Set mode selector switch to VENT position. Using test light connected to ground, probe
3)Set blower motor switch in low speed position. Using test light connected to ground, probe
4)Turn ignition switch to OFF position. Disconnect blower motor relay. Connect fused jumper wire between blower motor relay
harness connector terminal B2 (Dark Blue wire) and C1 (Purple wire). Turn ignition switch to ON position. Set mode selector switch to VENT position. Place blower motor switch in low speed position. If blower motor operates, go to step 8). If blower motor does not operate, go to step 7).
5)Check for poor connection or connector damage at blower switch harness connector. Repair or replace as necessary. After repair, go to step 20). If connection is okay, go to next step.
6)Replace blower motor switch. See BLOWER MOTOR SWITCH under REMOVAL & INSTALLATION. After repair, go to step 20).
7)Leave jumper wire connected as described in step 4). Turn ignition switch to OFF position. Disconnect blower motor harness connector. Turn ignition switch to ON position. Connect test light between blower motor harness connector terminals "A" (Black wire) and "B" (Purple wire). If test light illuminates, go to step 11). If test light does not illuminate, go to step 10).
8)Check for poor connection at blower motor relay harness connector. Repair or replace as necessary. After repair, go to step 20). If connection is okay, go to next step.
9)Replace blower motor relay. After repair, go to step 20).
10)Leave jumper wire connected. Using test light connected to ground, probe blower motor harness connector terminal "B" (Purple wire). If test light illuminates, go to step 14). If test light does not illuminate, go to step 13).
11)Check for poor connection or connector damage at blower motor harness connector. Repair or replace as necessary. After repair, go to step 20). If connection is okay, go to next step.
12)Replace blower motor. See BLOWER MOTOR under REMOVAL & INSTALLATION. After repair, go to step 20).
13)Repair open or poor connection in Purple wire between blower motor relay harness connector terminal C1 and blower motor harness connector terminal "B". After repair, go to step 20).
14)Repair open or poor connection in Black wire between ground and blower motor harness connector terminal "A". After repair, go to step 20).
15)Using test light connected to ground, probe
16)Check for open circuit or poor connection between A/C- heater control panel harness connector C2 terminals "B" (Light Green wire) and "C" (Brown wire). See WIRING DIAGRAMS. Repair or replace as necessary. After repair, go to step 20). If no problem is found, go to next step.
17)Check for poor connection(s) or connector damage at A/C- heater control panel switch harness connectors. Repair or replace as necessary. After repair, go to step 20). If connections are okay, go to next step.
18)Replace
19)Check for poor connection or wire damage in Brown wire between
20)Operate blower system to verify repair. If blower motor operates normally, repair is complete. If blower motor is still inoperative, return to step 3).
2001 Models
1)Perform DIAGNOSTIC SYSTEM TEST. Go to next step.
2)Turn ignition switch to ON position. Set mode selector switch to VENT position. Place blower motor switch in each speed
position. If blower operates in any position, problem is intermittent. Check for poor connections. loose components or damaged wiring. Repair or replace as necessary. After repair, go to step 16). If blower motor does not operate in any speed position, go to next step.
3)Turn ignition switch to OFF position. Disconnect blower motor harness connector. Turn ignition switch to ON position. Place blower motor switch in lowest speed position. Using test light connected to ground, probe blower motor harness connector terminal "B" (Purple wire). If test light illuminates, go to next step. If test light does not illuminate, go to step 5).
4)Check Black wire between blower motor harness connector terminal "A" and ground for open or high resistance. See
WIRING DIAGRAMS. Repair Black wire as necessary. After repair, go to step 16). If wire is okay, go to step 10).
5)Turn ignition switch to OFF position. Disconnect blower motor resistor harness connector. Turn ignition switch to ON position. Set blower motor switch to lowest speed position. Using test light connected to ground, probe blower motor resistor harness connector terminal "B" (Yellow wire). If test light does not illuminate, go to next step. If test light illuminates, go to step 8).
6)Check Yellow wire between blower motor resistor harness connector terminal "B" and
7)Turn ignition switch to OFF position. Disconnect A/C- heater control panel harness connector C2. See WIRING DIAGRAMS. Turn ignition switch to ON position. Using test light connected to ground, probe
8)Check Purple wire between blower motor relay harness connector terminal C1 and blower motor harness connector terminal "B" for open or high resistance. Repair Purple wire as necessary. After repair, go to step 16). If wire is okay, go to next step.
9)Check for poor connections or connector damage at blower motor relay harness connector. Repair of replace as necessary. After repair, go to step 16). If connections are okay, go to step 13).
10)Check for poor connections or connector damage at blower motor harness connector. Repair of replace as necessary. After repair, go to step 16). If connections are okay, go to step 14).
11)Check for poor connections or connector damage at A/C- heater control panel harness connector. Repair of replace as necessary. After repair, go to step 16). If connections are okay, go to step 15).
12)Repair Brown wire between HVAC fuse
13)Replace blower motor relay. After repair, go to step 16).
14)Replace blower motor. See BLOWER MOTOR under REMOVAL & INSTALLATION. After repair, go to step 16).
15)Replace
16) Operate blower system to verify repair. If blower motor operates normally, repair is complete. If blower motor is still inoperative, return to step 3).
BLOWER MOTOR OPERATES IN HIGH SPEED ONLY
2000 Models
1)Perform DIAGNOSTIC SYSTEM TEST. Go to next step.
2)Turn ignition switch to ON position. Set mode selector
switch in VENT position. Set blower motor switch in lowest speed position. Using test light connected to ground, probe blower motor resistor harness connector terminal "C" (Dark Blue wire). If test light illuminates, go to next step. If test light does not illuminate, go to step 4).
3)Using test light connected to ground, probe blower motor relay harness connector terminal B2 (Dark Blue wire). If test light illuminates, go to step 6). If test light does not illuminate, go to step 8).
4)Check for poor connection or connector damage at blower motor resistor harness connector. Repair or replace as necessary. After repair, go to step 9). If connection is okay, go to next step.
5)Replace blower motor resistor. See BLOWER MOTOR RESISTOR under REMOVAL & INSTALLATION. After repair, go to step 9).
6)Check for poor connection or connector damage at blower motor relay harness connector. Repair or replace as necessary. After repair, go to step 9). If connection is okay, go to next step.
7)Replace blower motor relay. After repair, go to step 9).
8)Repair open or poor connection in Dark Blue wire between blower relay harness connector terminal B2 and blower motor resistor harness connector terminal "C". After repair, go to next step.
9)Operate blower system to verify repair. If blower motor operates normally, repair is complete. If blower motor is still inoperative, return to step 3).
BLOWER SPEED INOPERATIVE IN LOW,
SPEED
2000 Models
1)Perform DIAGNOSTIC SYSTEM TEST. Go to next step.
2)Turn ignition switch to OFF position. Disconnect blower motor resistor harness connector. Turn ignition switch to ON position. Set blower motor switch in OFF position. Using test light connected to ground, probe
WIRING DIAGRAMS. If test light illuminates on suspect circuit. go to next step. If test light does not illuminate, go to step 5).
3)Check for poor connection or connector damage at blower motor resistor harness connector. Repair or replace as necessary. After repair, go to step 9). If connections are okay, go to next step.
4)Replace blower motor resistor. See BLOWER MOTOR RESISTOR under REMOVAL & INSTALLATION. After repair, go to step 9).
5)Using test light connected to ground, individually probe
6)Repair open or poor connection in Yellow, Tan or Light Blue wire(s) between
7)Check for poor connections or connector damage at A/C- heater control panel harness connector C1. Repair or replace as necessary. After repair, go to step 9). If connections are okay, go to next step.
8)Replace blower motor switch. See BLOWER MOTOR SWITCH under REMOVAL & INSTALLATION. After repair, go to next step.
9)Operate blower system to verify repair. If blower motor operates normally, repair is complete. If blower motor is still inoperative, return to step 3).
BLOWER MOTOR MALFUNCTIONS
2001 Models
1)Perform DIAGNOSTIC SYSTEM TEST. Go to next step.
2)Turn ignition switch to ON position. Set mode switch to VENT position. Turn blower switch to each speed position. If blower motor operates normally, go to next step. If blower motor malfunctions, go to step 4).
3)Place blower motor switch at maximum speed position. Place mode switch in each position. If blower operates in each switch position, problem is intermittent. Check for faulty wiring, poor connections or damaged components. Repair as necessary. After repair, go to step 24). If no problem is found, go to step 18).
4)Turn ignition switch to OFF position. Disconnect blower motor harness connector. Turn ignition switch to ON position. Using test light connected to ground, probe blower motor harness connector terminal "B" (Purple wire). Place blower motor switch in each speed position. If test light does not illuminate in each speed position, go to next step. If test light illuminates in all speed positions, go to step 16).
5)If test light does not illuminate in maximum speed position, go to next step. If test light illuminates in maximum speed position, go to step 10).
6)Turn ignition switch to OFF position. Disconnect blower motor relay. Turn ignition switch to ON position. Using test light connected to ground, probe blower motor relay harness connector terminal A2 (Red wire). If test light illuminates, go to next step. If test light does not illuminate, go to step 19).
7)Set blower motor switch in maximum speed position. Using test light connected to ground, probe blower motor relay harness connector terminal A1 (Orange wire). If test light does not illuminate, go to next step. If test light illuminates, go to step 9).
8)Check Orange wire between blower motor relay harness connector terminal A1 and blower motor switch harness connector C1 terminal "B" located at
9)Check Black wire for open or high resistance between blower motor relay harness connector terminal C2 and ground. Repair Black wire as necessary. After repair, go to step 24). If wire is okay, go to step 15).
10)Turn ignition switch to OFF position. Disconnect blower motor relay. Turn ignition switch to ON position. Using test light connected to ground, probe blower motor relay harness connector terminal B2 (Dark Blue wire). Alternately set blower motor switch in minimum, M1
11)Check Dark Blue wire between blower motor relay harness connector terminal B2 and blower motor resistor harness connector terminal "C" for short to ground, open or high resistance. Repair Dark Blue wire as necessary. After repair, go to step 24). If wire is okay, go to next step.
12)Turn ignition switch to OFF position. Disconnect blower motor resistor harness connector. Turn ignition switch to ON position. Set mode switch in VENT position. Using test light connected to ground, individually probe blower motor resistor harness connector terminals "A" (Tan wire), "B" (Yellow wire) and "D" (Light Blue wire). See WIRING DIAGRAMS. Set blower motor switch in speed position corresponding to wire being tested. If test light does not illuminate at any switch position, go to next step. If test light illuminates at each switch position, go to step 17).
13)Check suspect blower motor control circuit identified in previous step for open or high resistance. Repair suspect wire as necessary. After repair, go to step 24). If wire is okay, go to step 18).
14)Check Light Green wire between
15)Check for poor connections or connector damage at blower motor relay harness connector. Repair or replace as necessary. After repair, go to step 24). If connections are okay, go to step 20).
16)Check for poor connections or connector damage at blower motor harness connector. Repair or replace as necessary. After repair, go to step 24). If connections are okay, go to step 21).
17)Check for poor connections or connector damage at blower motor resistor harness connector. Repair or replace as necessary. After repair, go to step 24). If connections are okay, go to step 22).
18)Check for poor connections or connector damage at A/C- heater control panel harness connectors. Repair or replace as necessary. After repair, go to step 24). If connections are okay, go to step 23).
19)Repair Red wire between blower motor relay harness connector terminal A2 and
20)Replace blower motor relay. After repair, go to step 24).
21)Replace blower motor. See BLOWER MOTOR under REMOVAL & INSTALLATION. After repair, go to step 24).
22)Replace blower motor resistor. See BLOWER MOTOR RESISTOR under REMOVAL & INSTALLATION. After repair, go to step 24).
23)Replace
24) Operate blower system to verify repair. If blower motor operates normally, repair is complete. If blower motor is still inoperative, return to step 2).
REMOVAL & INSTALLATION
WARNING: To avoid injury from accidental air bag deployment, read and carefully follow all SERVICE PRECAUTIONS and DISABLING & ACTIVATING AIR BAG SYSTEM procedures in AIR BAG SYSTEM SAFETY article in GENERAL SERVICING.
A/C COMPRESSOR
Removal (3.8L Engine)
1)Disconnect negative battery cable from engine block ground stud. Discharge A/C system, using approved refrigerant recovery/recycling equipment. Remove serpentine drive belt. Disconnect electrical harness connector. Remove strap from compressor and condenser hose assembly.
2)Raise and support vehicle. Remove compressor and condenser hose bolt. Disconnect compressor and condenser hose assembly. Discard "O" ring. Remove compressor bolts. Remove compressor and rear bracket (if necessary).
Installation
1)To install, reverse removal procedure. If compressor is being replaced, drain refrigerant oil from old compressor. Measure amount of oil from old compressor. If measured amount is less than one ounce, add 2 ounces to new compressor.
2)If more than one ounce is drained from old compressor, add same amount to new compressor. Clean all fittings with
Removal (5.7L Engine)
Disconnect negative battery cable. Discharge A/C system, using approved refrigerant recovery/recycling equipment. Raise and support vehicle. Remove serpentine drive belt and tensioner. Remove compressor and condenser hose bolt. Disconnect compressor and condenser hose assembly. Discard seal. Disconnect transmission oil cooler pipes from engine bracket. Disconnect compressor electrical connector. Remove compressor bolts. Remove compressor.
Installation
1)To install, reverse removal procedure. If compressor is being replaced, drain refrigerant oil from old compressor. Measure amount of oil from old compressor. If measured amount is less than one ounce, add 2 ounces to new compressor.
2)If more than one ounce is drained from old compressor, add same amount to new compressor. Clean all fittings with
Removal & Installation
1)Disconnect negative battery cable. Remove center instrument panel trim plate. Remove
2)Pull
BLOWER MOTOR
Removal & Installation
Remove right side instrument panel insulator. Disconnect blower motor harness connector. Remove blower motor retaining bolts. Remove blower motor. To install, reverse removal procedure.
BLOWER MOTOR RESISTOR
Removal & Installation
Disconnect negative battery cable. Remove right instrument panel insulator. Pull carpet away from
BLOWER MOTOR SWITCH
Removal & Installation
Remove
. Pull off blower motor switch knob. Remove blower motor switch retaining screw. Remove blower motor switch from
CONDENSER
Removal & Installation
1) Disconnect negative battery cable. Discharge A/C system, using approved refrigerant recovery/recycling equipment. Remove air intake duct and air cleaner assembly. Remove upper radiator shroud assembly.
2)Raise and support vehicle. Remove compressor and condenser hose assembly fitting at condenser. Discard "O" ring. Lower vehicle. Remove accumulator tube. Remove radiator air upper baffle from condenser. Remove condenser.
3)To install, reverse removal procedure. Lightly coat "O" rings with
EVAPORATOR TUBE
Removal
Disconnect negative battery cable. Discharge A/C system, using approved refrigerant recovery/recycling equipment. Disconnect electrical connector at refrigerant pressure sensor. Remove strap from evaporator tube. Remove accumulator tube. See ACCUMULATOR. Remove evaporator tube fitting at accumulator and condenser. Remove evaporator tube and discard "O" rings.
Installation
To install, reverse removal procedure. Clean all fittings with
EVAPORATOR
Removal
1)Disconnect negative battery cable. Discharge A/C system, using approved refrigerant recovery/recycling equipment. Remove right instrument panel sound insulator panel. Drain cooling system. Remove heater hoses at heater core. Open glove box. Push sides of glove box and remove glove box. Remove heater core. See HEATER CORE.
2)Remove temperature control cable at
3)Place a mat on passenger side floor to protect carpeting. Using a small hand saw, remove perforated section of
Fig. 3: Exploded View Of
Courtesy of General Motors Corp.
Installation
1) To install, reverse removal procedure. Transfer condensate
screen to new evaporator. Using appropriate adhesive, install NEW evaporator core gasket in same position as original. Slide new evaporator to right until full seated in
2)Apply sealer (not epoxy) between evaporator and evaporator upper and lower case. Using epoxy, glue perforated section of heater and A/C evaporator case to
3)Slide temperature valve case upward into position until upper clip engages. Engage snap on left edge of
HEATER CORE
CAUTION: DO NOT use excessive force to remove heater hoses from heater core pipes. Heater core can be damaged.
Removal
Drain cooling system. Remove heater hoses from heater core pipes. Open glove box. Push sides of glove box and remove glove box. Remove heater module bolts and cover. Remove heater core bolt, heater core clamp and heater core.
Installation
To install, reverse removal procedure. Lubricate heater pipes. Verify seal is installed correctly by observing seal from inside engine compartment. If seal leaks, apply sealer between heater core pipes and evaporator housing. Refill cooling system.
ACCUMULATOR
Removal
Disconnect negative battery cable. Discharge A/C system, using approved refrigerant recovery/recycling equipment. Remove accumulator tube fitting at accumulator. Remove accumulator tube, and discard "O" ring. Remove evaporator tube fitting at accumulator. Remove accumulator from bracket, and discard "O" ring.
Installation
1)If accumulator is being replaced, drain and measure amount of refrigerant oil in old accumulator. Add drained amount plus one fluid ounce of new refrigerant oil to new accumulator.
2)Clean all fittings with
ORIFICE (EXPANSION) TUBE
CAUTION: If vehicle is equipped with a pressure switch mounted near orifice tube location, remove switch before heating inlet tube to prevent damage to switch.
Removal & Installation
1)Discharge A/C system, using approved refrigerant recovery/recycling equipment. Remove evaporator tube. See EVAPORATOR TUBE. Using
2)If removal of orifice tube is difficult, remove as much of the impacted residue as possible. Using a heat gun, apply heat 1/4" (7
mm)from dimples on inlet pipe. DO NOT overheat evaporator tube.
3)To install, reverse removal procedure. Lubricate new "O" ring with clean refrigerant oil prior to installation. DO NOT soak "O"
ring, as this will cause it to expand. Insert short screen end of orifice tube first. Evacuate, charge, and leak test A/C system.
TORQUE SPECIFICATIONS
TORQUE SPECIFICATIONS
???????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????
???????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????
WIRING DIAGRAMS
Fig. 4: Manual
Fig. 5: Manual
Fig. 6: Manual
Fig. 7: Manual
A00063334