Dinion2X IP Camera
en Installation and Operation Manual
1Safety
1.1Safety precautions
DANGER!
High risk: This symbol indicates an imminently hazardous situation such as "Dangerous Voltage" inside the product. If not avoided, this will result in an electrical shock, serious bodily injury, or death.
WARNING!
Medium risk: Indicates a potentially hazardous situation.
If not avoided, this could result in minor or moderate bodily injury.
CAUTION!
Low risk: Indicates a potentially hazardous situation.
If not avoided, this could result in property damage or risk of damage to the unit.
1.2Important safety instructions
Read, follow, and retain for future reference all of the following safety instructions. Follow all warnings on the unit and in the operating instructions before operating the unit.
1.Clean only with a dry cloth. Do not use liquid cleaners or aerosol cleaners.
2.Do not install unit near any heat sources such as radiators, heaters, stoves, or other equipment (including amplifiers) that produce heat.
3.Never spill liquid of any kind on the unit.
4.Take precautions to protect the unit from power and lightning surges.
5.Adust only those controls specified in the operating instructions.
6.Operate the unit only from the type of power source indicated on the label.
7.Unless qualified, do not attempt to service a damaged unit yourself. Refer all servicing to qualified service personnel.
8.Install in accordance with the manufacturer's instructions in accordance with applicable local codes. Use only attachments/accessories specified by the manufacturer. Equipment change or modification could void the user's guarantee or authorization agreement.
1.3Connection in applications
Power lines: An outdoor system should not be located in the vicinity of overhead power lines, electrical lights, or power circuits, or where it may contact such power lines or circuits. When installing an outdoor system, extreme care should be taken to keep from touching power lines or circuits, as this contact may be fatal.
U.S.A. models only - refer to the National Electrical Code Article 820 regarding installation of CATV systems.
12 VDC / 24 VAC power source: This unit is intended to operate with a limited power source. The unit is intended to operate at either 12 VDC or 24 VAC (if PoE is not available). User supplied wiring must be in compliance with electrical codes (Class 2 power levels). If 24 VAC is used, do not ground the 24 VAC supply at the terminals or at the unit's power supply terminals.
PoE: Use only approved PoE devices.
CAUTION!
The Low Voltage power supply unit must comply with EN/UL 60950. The power supply must be a
1.4FCC & ICES compliance
FCC & ICES Information
(U.S.A. and Canadian Models Only)
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
???reorient or relocate the receiving antenna;
???increase the separation between the equipment and receiver;
???connect the equipment into an outlet on a circuit different from that to which the receiver is connected;
???consult the dealer or an experienced radio/TV technician
for help.
Intentional or unintentional modifications, not expressly approved by the party responsible for compliance, shall not be made. Any such modifications could void the user's authority to operate the equipment. If necessary, the user should consult the dealer or an experienced radio/television technician for corrective action.
The user may find the following booklet, prepared by the Federal Communications Commission, helpful: How to Identify and Resolve
Informations FCC et ICES
(mod??les utilis??s aux
Suite ?? diff??rents tests, cet appareil s'est r??v??l?? conforme aux exigences impos??es aux appareils num??riques de classe B, en vertu de la section 15 du r??glement de la Commission f??d??rale des communications des
???Modifier l'orientation ou l'emplacement de l'antenne r??ceptrice;
?????loigner l'appareil du r??cepteur;
???Brancher l'appareil sur une prise situ??e sur un circuit diff??rent de celui du r??cepteur;
???Consulter le revendeur ou un technicien qualifi?? en radio/ t??l??vision pour obtenir de l'aide.
Toute modification apport??e au produit, non express??ment approuv??e par la partie responsable de l'appareil, est strictement interdite. Une telle modification est susceptible d'entra??ner la r??vocation du droit d'utilisation de l'appareil. La brochure suivante, publi??e par la Commission f??d??rale des communications (FCC), peut s'av??rer utile : Comment identifier et r??soudre les probl??mes d???interf??rences de radio et de t??l??vision. Cette brochure est disponible aupr??s du U.S. Government Printing Office, Washington, DC 20402,
1.5UL certification
Disclaimer
Underwriter Laboratories Inc. ("UL") has not tested the performance or reliability of the security or signaling aspects of this product. UL has only tested fire, shock and/or casualty hazards as outlined in UL's Standard(s) for Safety for Information Technology Equipment, UL
UL MAKES NO REPRESENTATIONS, WARRANTIES, OR
CERTIFICATIONS WHATSOEVER REGARDING THE
PERFORMANCE OR RELIABILITY OF ANY SECURITY OR
SIGNALING RELATED FUNCTIONS OF THIS PRODUCT.
Disposal - Your Bosch product was developed and manufactured with
1.6Bosch notices
Video loss
Video loss is inherent to digital video recording; therefore, Bosch Security Systems cannot be held liable for any damage that results from missing video information. To minimize the risk of lost digital information, Bosch Security Systems recommends multiple, redundant recording systems, and a procedure to back up all analog and digital information.
Copyright
This manual is the intellectual property of Bosch Security Systems and is protected by copyright.
All rights reserved.
Trademarks
All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly.
Note
This manual has been compiled with great care and the information it contains has been thoroughly verified. The text was complete and correct at the time of printing. The ongoing development of the products may mean that the content of the user guide can change without notice. Bosch Security Systems accepts no liability for damage resulting directly or indirectly from faults, incompleteness or discrepancies between the user guide and the product described.
More information
For more information please contact the nearest Bosch Security Systems location or visit www.boschsecurity.com
1.7Copyrights
The firmware 4.1 uses the fonts
Copyright
This software is based in part on the work of the Independent JPEG Group.
2Introduction
2.1Features
The Dinion2x IP Day/Night camera is a
The camera uses H.264 compression technology to give clear images while reducing bandwidth and storage requirements. It is also ONVIF compliant to improve compatibility during system integration.
The camera operates as a network video server and transmits video and control signals over data networks, such as Ethernet LANs and the Internet.
The camera is easy to install and ready to use. Features include:
???Progressive scan
???True Day/Night performance with switchable IR filter
???
???
???Complies with the ONVIF standard for wide compatibility
???
???Alarm input and alarm output to external devices
???Dynamic engine with Smart BLC
???Six
???Adaptive dynamic noise reduction
???Enhanced video motion detection
???Video and data transmission over IP data networks
???Multicast function for simultaneous picture transmission to multiple receivers
???Integrated Ethernet interface (10/100
???
???Remote control of all
???Data interface RS485/RS422/RS232 for control of pan or tilt heads or motorized zoom lenses (PTZ control)
???Password protection to prevent unauthorized connection or configuration changes
???
???Fast, convenient configuration using the integrated Web server and a browser
???Firmware update through flash memory
???Convenient upload and download of configuration data
3System Information
3.1Overview of functions
The camera incorporates a network video server. Its primary function is to encode video and control data for transmission over an IP network. With its H.264 encoding, it is ideally suited for IP communication and for remote access to digital video recorders and IP systems. The use of existing networks means that integration with CCTV systems or local networks can be achieved quickly and easily. Video images from a single camera can be simultaneously received on several receivers.
3.1.1Progressive scan
The camera captures and processes progressively scanned images. When there is fast motion in a scene, progressively scanned images are generally sharper than interlaced images.
3.1.2Day/Night function
The Day/Night function provides enhanced night viewing by increasing the IR sensitivity. The motorized IR filter can be removed in
3.1.3Wide dynamic range
A unique combination of
3.1.4
3.1.5ONVIF (Open Network Video Interface Forum)
The camera complies to the ONVIF standard which means that it is easier to install and integrate into larger systems. The ONVIF standard is a global standard for the interface of network video products.
3.1.6Audio
3.1.7Alarm I/O
The alarm input can be used to control the functionality of the unit. An alarm output can control external devices.
3.1.8Tamper detection and motion detectors
The camera offers a wide range of configuration options for alarm signaling in the event of tampering with the camera. An algorithm for detecting movement in the video image is also part of the scope of delivery and can optionally be extended to include special video analysis algorithms.
3.1.9Video encoding
The camera uses the H.264 compression standards. Thanks to efficient encoding, the data rate remains low even with high image quality and can also be adapted to local conditions within wide limits.
3.1.10Multicast
In suitably configured networks, the multicast function enables simultaneous, real time transmission to multiple receivers. The prerequisite for this is that the UDP and IGMP V2 protocols are implemented on the network.
3.1.11
Power for the camera can be supplied via a
3.1.12Encryption
The unit offers a variety of options for protection against unauthorized reading. Web browser connections can be protected using HTTPS. Protect the control channels via the SSL encryption protocol. With an additional license, the user data itself can be encrypted.
3.1.13Receiver
H.264 compatible hardware decoders can be used as a receiver. Computers with decoding software such as VIDOS, or computers with the Microsoft Internet Explorer web browser installed, can also be used as receivers.
3.1.14Recording
The camera can be used with an iSCSI server connected via the network to store
3.1.15Snapshots
Individual video frames (snapshots) can be called up as JPEG images, stored on the hard drive, or displayed in a separate browser window.
3.1.16Backup
The browser application has an icon for saving the video images provided by the unit as a file on your computer's hard drive. Clicking this icon stores the video sequences and they can be replayed with the Player from Bosch Security Systems included with the package.
3.1.17Configuration
The camera can be configured using a browser on the local network (Intranet) or from the Internet. Similarly, firmware updates and rapid loading of device configurations are also
possible. Configuration settings can be stored as files on a computer and copied from one camera to another.
3.2Operation with external systems
The camera can be used with a variety of Bosch software and hardware systems:
???Bosch Video Management System
???VIDOS video management software
???DiBos 900 Series digital video recorder
???Divar 700 Series digital video recorder
Note:
When connected to any of these systems, many of the camera configuration parameters are controlled by the system and not by the settings made via a web browser connected to the camera.
Bosch Video Management System
The Bosch Video Management System is a unique enterprise IP video surveillance solution that provides seamless management of digital video, audio, and data across any IP network. It is designed to work with Bosch CCTV products as part of a total video surveillance management system. Integrate your existing components into one
VIDOS
The camera video server and VIDOS software combine to provide a
DiBos 900 Series
The camera is also designed for use with DiBos 900 Series Video Recorders. DiBos can record up to 32 video and audio
streams, and is available as software or as a hybrid DVR with additional analog camera and audio inputs. DiBos supports various functions of the camera, such as controlling relays, remote control of peripheral devices, and remote configuration. DiBos can use alarm inputs to trigger actions and, when motion detection Motion+ is active, can record the relevant cells, making intelligent motion detection possible.
Divar 700 Series
The Divar 700 Series of digital video recorders can view and record images from the camera via a network connection. The Divar 700 Series controls the camera so that the correct settings are used.
4Planning
4.1Unpacking
Unpack carefully and handle the equipment with care. The packaging contains:
???Dinion2X IP camera
???CCD protection cap (mounted on camera)
???Power connector
???Alarm I/O connector
???Data connector
???Spare lens connector (male)
???DVD ROM (mini)
???Manual
???System requirements
???Configuration Manager
???BVIP Lite Suite
???MPEG ActiveX control
???DirectX control
???Microsoft Internet Explorer
???Sun JVM
???Player and Archive Player
???Adobe Acrobat Reader
???Quick install instructions
???Safety instructions
If equipment has been damaged during shipment, repack it in the original packaging and notify the shipping agent or supplier.
4.2System requirements
???Computer with Windows XP/Vista operating system, network access, and Microsoft Internet Explorer web browser version 7.0 or later
or
???Computer with Windows XP/Vista operating system, network access and reception software, for example VIDOS, Bosch VMS, or DIBOS 900 Series
or
???H.264 compatible hardware decoder from
Bosch Security Systems (such as VIP XD) as a receiver and a connected video monitor
or
???Divar 700 Series Digital Video Recorder
The minimum PC requirements are:
???Operating platform: A PC running Windows XP or Windows Vista with IE 7.0
???Processor: Dual core, 3.0 GHz
???RAM memory: 256 MB
???Monitor resolution: 1024 x 768
???Network interface:
???DirectX: 9.0c
Make sure the graphics card is set to
4.3Install players
Play back
to play back saved sequences using the Player, suitable ActiveX software must be installed on the computer.
1.Insert the DVD into the
2.Select a language from the list box at the top.
3.Click Tools in the menu.
4.Click Archive Player; the installation starts.
5.Follow the instructions in the installation program. The Archive Player is installed together with the Player.
6.After a successful installation, two new icons for the Player and the Archive Player appear on the desktop.
7.
5Installation
CAUTION!
Installation should only be performed by qualified service personnel in accordance with the National Electrical Code or applicable local codes.
5.1Network (and power) connector
??? +
12 VDC 24 VAC
UTP Cat 5 RJ45
Figure 5.1 Network connection
???Connect the camera to a 10/100
???Use screened UTP Category 5e cable with RJ45 connectors (the camera network socket is Auto MDIX compliant).
???Power can be supplied to the camera via the Ethernet
cable compliant with the
The multicolored LED beside the Ethernet connection indicates Power (red), IP connection (green) and IP traffic (green flashing). It can be disabled in the Settings/Camera Settings/ Install options menu.
By default, power is supplied to the camera via the Ethernet cable, compliant with the
5.2Power connector
ALARM
1 3
E
1 2 3
??? +
VDC
VAC
DATA
4 5 6
5 mm
0.2 in
Figure 5.2 Power connection
Connect power from a 24 VAC or 12 VDC class 2 power supply as follows:
???Use AWG16 to 22 stranded wire or AWG16 to 26 solid wire; cut back 5 mm (0.2 in) of insulation.
???Loosen the screws of the supplied
???Tighten the screws and insert the
Note:
For a DC supply the polarity is important. Incorrect polarity does not damage the camera but it will not switch on.
5.3Alarm and relay connector
Figure 5.3 Alarm and relay connector pins
???Max. wire diameter AWG
???Alarm output relay switching capability: Max voltage 30VAC or +40 VDC. Max 0.5 A continuous, 10 VA.
???Alarm in: TTL logic, +5V nominal, +40 VDC max, DC coupled with 22 kOhm
???Alarm in: configurable as active low or active high.
???Max. 42 V allowed between camera ground and each of the
relay pins.
Use the alarm input to connect external alarm devices such as door contacts or sensors. A zero potential
Use the alarm relay output for switching external devices such as lamps or sirens.
5.4Audio connectors
Line
GND
AUDIO IN
E T H
P o E
AUDIO OUT
Figure 5.4 Audio connectors
Connect audio devices to the Audio In and Audio Out connectors.
The unit has
Audio input: Line input level (not suitable for direct microphone signal); impedance 9 kOhm typical; 5.5 Vpp maximum input voltage.
Audio output: Line output level (not suitable for direct speaker connection); impedance 16 Ohm minimum; 3 Vpp maximum output voltage.
Wiring: Shielded audio connection cable is advised. Observe maximum cable lengths for audio line input and output levels.
5.5Video service monitor connector
AUDIO IN
E T H
P o E
AUDIO OUT
Figure 5.5 Video BNC connector
1.Connect a service monitor to the composite video BNC connector to aid installation.
2.Open the side panel on the camera and press the center button for longer than 2 seconds. This stops the IP video stream and enables the video analog output.
5.6Data connector
1 Ground
2 RxD / Rx+
3CTS / Rx-
4 Ground
5 TxD / Tx-
6RTS / Tx+
The data connector is used to connect the control data coming out of the camera to external devices. RS485, RS422, and RS232 is supported by this data connection.
Note:
To ensure surge and electrostatic protection, keep the cable length between the camera and external device to less than 3 meters.
5.7Lens mounting
The camera accepts
CAUTION!
To avoid damaging the CCD sensor when using a
CAUTION!
Lenses weighing more than 0.5 kg (1.1lbs) must be separately supported.
Figure 5.7 Mounting a lens
Figure 5.8 Lens connector
Note
If a short circuit is detected on the lens connector, the message LENS SHORT CIRCUIT is shown. The lens circuit is automatically disabled to avoid internal damage. Remove the lens connector and check the pin connections.
5.8Mounting the camera
The camera can be mounted either from the top or from the bottom (1/4" 20 UNC thread).
Figure 5.9 Mounting a camera
CAUTION!
The CCD image sensors are highly sensitive and require special care for proper preformance and extended lifetime. Do not expose them, or point the camera/lens, to direct sunlight.
Do not obstruct the free flow of air around the camera.
5.9Using the camera install menu
Five keys, located behind the side door panel, are used for accessing the camera menu.
Bosch
Bosch
To open the install menu press and hold the center key for approximately two seconds. The BNC video output is activated and the Install menu appears on the monitor.
5.10Back focus adjustment
To optimize picture sharpness in both bright and
???When back focusing varifocal lenses, adjust to obtain a sharp picture in both
???When back focusing zoom lenses, ensure the object of interest remains in focus throughout the entire zoom range
of the lens.
To adjust back focus:
1.Slide open the door panel at the side of the camera.
2.Unlock the back focus locking button.
3.Press and hold the center key for more than 2 seconds until the Install menu appears.
4.Select Len Wizard and move cursor to the Set Back Focus Now item.
5.Turn the back focus adjustment as required.
6.Lock the back focus locking button.
7.Press and hold the center key for more than 2 seconds until all the menus disappear.
8.Close the side door panel.
5.11Lens adjustment
5.11.1
1.Unlock the back focus locking button.
2.Access the Lens Wizard menu.
3.Set Back Focus Now is highlighted in the menu.
4.Turn the back focus adjustment as required.
5.Lock the back focus locking button.
6.Exit the menu.
5.11.2
1.Unlock the back focus locking button.
2.Adjust the lens to the maximum lens opening.
3.Turn the back focus adjustment as required.
4.Lock the back focus locking button.
5.11.3
1.Unlock the back focus locking button.
2.Access the Lens Wizard menu.
3.Set Back Focus Now is highlighted in the menu.
4.Turn the back focus adjustment as required.
5.Lock the back focus locking button.
6.Select Set LVL in the menu; the Level bar appears.
7.Point the camera at the scene it will be mostly viewing.
8.Adjust the level potentiometer located on the lens until the Level bar is in the central position.
9.Exit the menu.
The best performance with video iris lenses is obtained when the peak/average potentiometer of the lens matches the peak/ average balance configuration setting.
5.12Reset button
AUDIO IN
Figure 5.10 Reset button
With the power on, use a small pointed object to press and hold the reset button for more than 10 seconds to restore the factory defaults. This is useful to restore the default IP address or to restore a previous version of the firmware if uploading a new version fails.
6Camera
The camera normally provides an optimal picture without the need for further adjustments. Configuration of the camera is carried out remotely via the network using a web browser.
However, the camera also has a
6.1Camera menu navigation
Five keys are used for navigating through menu system.
Up key
Menu/Select key (center)
Right key
Down key
Left key
Figure 6.1 Navigation
???To open the install menu and enable the analog video output, press and hold the center key for approximately two seconds. This turns off the IP video stream.
???Use the up or down keys to scroll through a menu.
???Use the left or right keys to move through options or to set parameters.
???When in a menu, quickly
???To close all menus at once hold down the menu/select key until the menu display disappears or continually select the Exit item. (This turns the IP video stream back on.)
Some menus automatically close after about two minutes; other menus have to be closed manually.
6.2Install menu
When the Install menu is opened, the MAC address of the unit is shown. This is factory set and cannot be changed. (To ensure that the correct MAC address is displayed, wait 20 seconds after
The items in the Install menu include the Mode selection, the Lens Wizard submenu, the Network submenu, and the Defaults submenu.
Note:
Camera parameter
Section 9.6 Camera for the specific camera menus.
6.2.1
There are six
1.
Default installation mode to provide stable pictures over a
2.Traffic
Capture
3.Low light
Provide extra enhancement, such as AGC and SensUp to make usable pictures in
4.Smart BLC
Settings optimized to capture details in high contrast and extremely
5.Low noise
Enhancements are set to reduce picture noise. Useful for conditional refresh DVR and IP storage systems because reducing noise reduces the amount of storage required.
6.Infrared
Use this mode if the camera is viewing a scene lit by infrared light.
6.2.2Lens Wizard submenu
6.2.3Network submenu
To operate the camera in your network, a
192.168.0.1
The new IP address, subnet mask, and gateway address are set when leaving the menu. The camera reboots internally and the new values are set after a few seconds.
6.2.4Defaults submenu
6.3Day/Night switching
The camera is equipped with a motorized IR filter. The mechanical IR filter can be removed in
There are four different methods of controlling the IR filter:
???via an alarm input,
???automatically, based on the observed light levels, or
???as part of the programmable mode profile.
7Browser connection
A computer with Microsoft Internet Explorer can be used to receive live images from the camera, control cameras, and replay stored sequences. The camera is configured over the network using the browser (or via the supplied Configuration Manager). The configuration options using the menu system of the camera itself are limited to setting up the lens and network.
Note:
The camera can also be connected to DIBOS 900 Series, VIDOS, Bosch Video Management System, and Divar 700 Series Digital Video Recorder, as well as third party video management systems.
7.1System requirements
???Microsoft Internet Explorer version 7.0 or higher
???Monitor: resolution at least 1024 ?? 768 pixels, 16 or 32 bit color depth
???Sun JVM installed
???Intranet or Internet network access
The Web browser must be configured to enable Cookies to be set from the IP address of the unit.
In Windows Vista, deactivate protected mode on the Security tab under Internet Options.
Read the information in the System Requirements document on the product DVD supplied and, if necessary, install the required programs and controls.
To play back live video images, an appropriate ActiveX must be installed on the computer. If necessary, the required software and controls can be installed from the product DVD provided.
a.Insert the
b.Follow the
7.2Establishing the connection
The camera must be assigned a valid IP address to operate on your network. The default address
192.168.0.1
1.Start the Web browser.
2.Enter the IP address of the camera as the URL.
Note:
If the connection is not established, the maximum number of possible connections may already have been reached. Depending on the device and network configuration, up to 25 web browsers, or 50 VIDOS or Bosch VMS connections are supported.
7.2.1Password protection in camera
A camera offers the option of limiting access across various authorization levels. If the camera is
1.Enter the user name and the associated password in the appropriate fields.
2.Click OK. If the password is correct, the desired page is displayed.
7.3Protected network
If a Radius server is used for network access control (802.1x authentication), the camera must be configured first. To configure the camera for a Radius network, connect it directly to a PC via a crossed network cable and configure the two parameters, Identity and Password. Only after these have been configured can communication with the camera via the network occur.
7.4Connecting to a hardware decoder
A compatible H.264 hardware decoder with a monitor can be connected to the camera using an Ethernet network connection. Cameras are designed to automatically connect with other BVIP devices with the correct configuration. The units only need to be part of the same closed network. In this way it is possible to cover large distances with little installation or cabling effort.
7.4.1Alarm connection
With the appropriate configuration, a connection between camera and decoder is established automatically when an alarm is triggered. After a short time, the live video image from the transmitter is shown on the connected monitor. In this case, no computer is needed to establish the connection
Note:
Make sure the devices are configured for the network environment and that the correct IP address for the remote location is set on the Alarm connections configuration page.
7.5Connection established
When a connection is established, the LIVEPAGE is initially displayed. The application title bar displays three items:
LIVEPAGE, RECORDINGS, SETTINGS.
Note:
The RECORDINGS link is only visible if a storage medium is available.
Figure 7.1 Livepage
7.5.1LIVEPAGE
The LIVEPAGE is used to display and control the video stream. Refer to Section 10 Operation via the browser, page 114 for more information.
7.5.2RECORDINGS
Click RECORDINGS in the application title bar to open the playback page. Refer to Section 10 Operation via the browser, page 114 for more information.
7.5.3SETTINGS
Click SETTINGS in the application title bar to configure the camera and the application interface. A new page containing
the configuration menu is opened. All settings are stored in the camera memory so that they are retained, even if the power is interrupted.
Changes that influence the fundamental functioning of the unit (for example, firmware updates) can only be made using the configuration menu.
The configuration menu tree allows all parameters of the unit to be configured. The configuration menu is divided into Basic Mode and Advanced Mode.
Refer to Section 8 Basic Mode, page 48 for more information on basic settings; refer to Section 9 Advanced Mode, page 53 for more information on advanced settings.
Note:
It is recommended that only expert users or system administrators use the Advanced Mode.
8Basic Mode
8.1Basic Mode menu tree
The basic mode configuration menu allows a set of basic camera parameters to be configured.
Basic Mode
>Device Access
>Date/Time
>Network
>Encoder Profile
>Audio
>Recording
>System Overview
To view the current settings:
1.If necessary, click the Basic Mode menu to expand it. The
2.Click a
The settings are changed by entering new values or by selecting a
Saving changes
After making changes in a window, click Set to send the new settings to the device and save them there.
Clicking Set saves only the settings in the current window. Changes in any other windows are ignored.
Click SETTINGS in the applications title bar to close the window without saving the changes.
Note:
Device time settings are lost after 1 hour without power if no central time server is selected.
Note:
When entering names do not use any special characters, for example &. Special characters are not supported by the internal recording management system.
8.2Device Access
8.2.1Camera name
Assign a name to assist in identification. This name simplifies the management of multiple devices in more extensive systems. The name is used for remote identification, for example, in the event of an alarm. Enter a name that makes it as easy as possible to identify the location unambiguously.
8.2.2Password
A password prevents unauthorized access to the device. The device recognizes three authorization levels: service, user, and
live.
???service is the highest authorization level. Entering the correct password gives access to all the functions of the camera and allows all configuration settings to be changed.
???user is the middle authorization level. This user can operate the device, play back recordings, and also control a camera but cannot change the configuration.
???live is the lowest authorization level. It can only be used to view the live video image and switch between the different live image displays.
Use the various authorization levels to limit access. Proper password protection is only guaranteed if all higher authorization levels are also protected with a password. For example, if a live password is assigned, a service and a user password should also be set. When assigning passwords, always start from the highest authorization level, service, and use different passwords.
Password
Define and change a separate password for each level while logged in as service or if the device is not protected by a password. Enter the password for the selected level.
Confirm password
The new password is only saved after clicking Set. Therefore, click Set immediately after entering and confirming the password, even if assigning a password at another level.
8.3Date/Time
Device date, time and zone
If there are multiple devices operating in the system or network, it is important to synchronize their internal clocks. For example, it is only possible to identify and correctly evaluate simultaneous recordings when all devices are operating on the same time.
As the device time is controlled by the internal clock, it is not necessary to enter the day or date of the week. These are set automatically. The time zone in which the system is located is also set automatically.
1.Click Sync to PC to apply the system time from your computer to the device.
Time server IP address
The camera can receive the time signal from a time server using various time server protocols and then use it to set the internal clock. The device polls the time signal automatically once every minute. Enter the IP address of a time server.
Time server type
Select the protocol that is supported by the selected time server. It is recommended to select the SNTP server protocol. This protocol provides high accuracy and is required for special applications and future function extensions. Select Time server if the server uses the RFC 868 protocol.
Note:
It is important to ensure that the date/time is correct for recording. An incorrect date/time setting could prevent correct recording.
8.4Network
Use the settings on this page to integrate the device into a network. Some changes only take effect after a reboot. In this case, the Set button changes to Set and Reboot.
1.Make the desired changes.
2.Click Set and Reboot.
???The device is rebooted and the changed settings are activated. If the IP address, subnet mask, or gateway address is changed, then the device is only available under the new addresses after the reboot.
DHCP
If the network has a DHCP server for dynamic IP address allocation, set this parameter to On to activate the automatic acceptance of
Note:
Certain applications (for example, Bosch Video Management System) use the IP address for the unique assignment of the device. If using these applications, the DHCP server must support the fixed assignment between IP address and MAC address, and must be appropriately set up so that, once an IP address is assigned, it is retained each time the system is rebooted.
IP address
Enter the desired IP address for the camera. The IP address must be valid for the network.
Subnet mask
Enter the appropriate subnet mask for the set IP address.
Gateway address
Enter the IP address of the gateway to establish a connection to a remote location in a different subnet. Otherwise, this field can remain empty (0.0.0.0).
8.5Encoder Profile
Select a profile for encoding the video signal.
8.6Audio
Switch the camera audio On or Off. Adjust the input and output levels with the sliders.
8.7Recording
Record the images from the camera to a storage medium. For
Divar 700 Series Digital Video Recorder or an appropriately sized iSCSI system.
8.7.1Storage medium
1.Select the required storage medium from the list.
2.Click Start to start recording or Stop to end recording.
8.8System Overview
This page provides general information on the hardware and firmware system, including version numbers. No items can be changed on this page but they can be copied for information purposes when troubleshooting.
9Advanced Mode
9.1Advanced Mode menu tree
The advanced mode configuration menu contains all camera parameters that can be configured.
Advanced Mode
To view the current settings:
1.Click the Advanced Mode menu to expand it. The associated menu
2.Click a menu
3.Click a
The settings are changed by entering new values or by selecting a
Saving changes
After making changes in a window, click Set to send the new settings to the device and save them there.
Clicking Set saves only the settings in the current window. Changes in any other windows are ignored.
Click SETTINGS in the applications title bar to close the window without saving the changes made.
Note:
Device time settings are lost after 1 hour without power if no central time server is selected.
Note:
When entering names do not use any special characters, for example &. Special characters are not supported by the internal recording management system.
9.2General
General
>Identification
>Password
>Date/Time
>Display Stamping
9.2.1Identification
Camera ID
Each device should be assigned a unique identifier that can be entered here as an additional means of identification.
Camera name
Assign a name to assist in identification. This name simplifies the management of multiple devices in more extensive systems. The name is used for remote identification, for example, in the event of an alarm. Enter a name that makes it as easy as possible to identify the location unambiguously.
Initiator extension
Add text to an initiator name to make identification easier in large iSCSI systems. This text is added to the initiator name, separated from it by a full stop.
9.2.2Password
A password prevents unauthorized access to the device. The device recognizes three authorization levels: service, user, and
live.
???service is the highest authorization level. Entering the correct password gives access to all the functions of the camera and allows all configuration settings to be changed.
???user is the middle authorization level. This user can operate the device, play back recordings, and also control a camera but cannot change the configuration.
???live is the lowest authorization level. It can only be used to view the live video image and switch between the different live image displays.
Use the various authorization levels to limit access. Proper password protection is only guaranteed if all higher authorization levels are also protected with a password. For example, if a live password is assigned, a service and a user password should also be set. When assigning passwords, always start from the highest authorization level, service, and use different passwords.
Password
Define and change a separate password for each level while logged in as service or if the device is not protected by a password. Enter the password for the selected level.
Confirm password
The new password is only saved after clicking Set. Therefore, click Set immediately after entering and confirming the password, even if assigning a password at another level.
9.2.3Date/Time
Date format
Select the required date format.
Device date / Device time
If there are multiple devices operating in your system or network, it is important to synchronize their internal clocks. For example, it is only possible to identify and correctly evaluate simultaneous recordings when all devices are operating on the same time.
1.Enter the current date. Since the device time is controlled by the internal clock, it is not necessary to enter the day of the week ??? it is added automatically.
2.Enter the current time or click Sync to PC to apply the system time from your computer to the device.
Note:
It is important to ensure that the date/time is correct for recording. An incorrect date/time setting could prevent correct recording.
Device time zone
Select the time zone in which the system is located.
Daylight saving time
The internal clock can switch automatically between normal and daylight saving time (DST). The device already contains the data for DST
Note:
If a table is not created, there is no automatic switching. When editing the table, note that values occur in linked pairs (DST start and end dates).
First, check the time zone setting. If it is not correct, select the appropriate time zone for the system:
1.Click Set.
2.Click Details. A new window opens showing an empty table.
3.Click Generate to fill the table with the preset values from the camera.
4.Select the region or the city which is closest to the system's location from the list box below the table.
5.Click one of the entries in the table to make changes. The entry is highlighted.
6.Click Delete to remove the entry from the table.
7.Choose other values from the list boxes under the table, to change the selected entry. Changes are immediate.
8.If there are empty lines at the bottom of the table, for example after deletions, add new data by marking the row and selecting values from the list boxes.
9.When finished, click OK to save and activate the table.
Time server IP address
The camera can receive the time signal from a time server using various time server protocols and then use it to set the internal clock. The device polls the time signal automatically once every minute. Enter the IP address of a time server.
Time server type
Select the protocol that is supported by the selected time server. It is recommended to select the SNTP server protocol. This protocol provides high accuracy and is required for special applications and future function extensions. Select Time server if the server uses the RFC 868 protocol.
9.2.4Display Stamping
Various overlays or stamps in the video image provide important supplementary information. These overlays can be enabled individually and arranged on the image in a clear manner.
Camera name stamping
This field sets the position of the camera name overlay. It can be displayed at the Top, at the Bottom, or at a position of choice using the Custom option, or it can be set to Off for no overlay information.
If the Custom option is selected, enter values in the X and Y position fields.
Time stamping
This field sets the position of the time and date overlay. It can be displayed at the Top, at the Bottom, or at a position of choice using the Custom option, or it can be set to Off for no overlay information.
If the Custom option is selected, enter values in the X and Y position fields.
Display milliseconds
If necessary, display milliseconds for Time stamping. This information can be useful for recorded video images; however,
it does increase the processor's computing time. Select Off if displaying milliseconds is not needed.
Alarm mode stamping
Select On for a text message to be overlaid in the event of an alarm. It can be displayed at a position of choice using the Custom option, or it can be set to Off for no overlay information.
If the Custom option is selected, enter values in the X and Y position fields.
Alarm message
Enter the message to be displayed on the image in the event of an alarm. The maximum text length is 31 characters.
Video watermarking
Select On for the transmitted video images to be watermarked. After activation, all images are marked with a green W. A red W indicates that the sequence (live or saved) has been manipulated.
9.3Web Interface
Web Interface
>Appearance
>LIVEPAGE Functions
>Logging
9.3.1Appearance
Adapt the appearance of the web interface and change the website language to meet your requirements. If necessary, replace the company's logo (top right) and the device name (top left) in the top part of the window with individual graphics. Either GIF or JPEG images can be used. The file paths must correspond to the access mode (for example, C:\Images\Logo.gif for access to local files or http:// www.myhostname.com/images/logo.gif for access via the Internet/Intranet). For access via the Internet/Intranet, there must be a connection in order to display the image. The image files are not stored on the camera.
To restore the original graphics, delete the entries in the Company logo and Device logo fields.
Website language
Select the language for the user interface here.
Company logo
Enter the path to a suitable image in this field. The image can be stored on a local computer, a local network, or at an Internet address.
Device logo
Enter the path for a suitable image for the device logo in this field. The image can be stored on a local computer, a local network, or at an Internet address.
JPEG interval
Specify the interval at which the individual images should be generated for the
9.3.2LIVEPAGE Functions
In this window, adapt the Livepage functions to meet your requirements. Choose from a variety of different options for displaying information and controls.
1.Mark the check boxes for the functions to be displayed on the Livepage. The selected elements are checked.
2.Check the Livepage to see how the desired items are available.
Transmit audio
When selected, the audio from the camera (if on) is sent to the computer.
Show alarm inputs
The alarm inputs are displayed next to the video image as icons along with their assigned names. If an alarm is active, the corresponding icon changes color.
Show relay outputs
The relay output is shown next to the video image as an icon along with its assigned name. If a relay is switched, the icon changes color.
Show VCA trajectories
The trajectories (motion lines of objects) from the video content analysis are displayed in the live video image if a corresponding analysis type is activated.
Show VCA metadata
When video content analysis (VCA) is activated, additional information is displayed in the live video stream. For example, in Motion+ mode, the sensor areas for motion detection are marked.
Show event log
The event messages are displayed with the date and time in a field next to the video image.
Show system log
The system messages are displayed with the date and time in a field next to the video image and provide information about the establishment and termination of connections, etc.
Allow snapshots
Specify whether the icon for saving individual images should be displayed below the live image. Individual images can only be saved if this icon is visible.
Allow local recording
Specify whether the icon for saving video sequences on the local memory should be displayed below the live image. Video sequences can only be saved if this icon is visible.
Path for JPEG and video files
Enter the path for the storage location of individual images and video sequences saved from the Livepage. If necessary, click Browse to find a suitable folder.
9.3.3Logging
Save event log
Select this option to save event messages in a text file on the local computer. This file can be viewed, edited, and printed with any text editor or standard office software.
File for event log
Enter the path for saving the event log here. If necessary, click Browse to find a suitable folder.
Save system log
Select this option to save system messages in a text file on the local computer. This file can be viewed, edited, and printed with any text editor or standard office software.
File for system log
Enter the path for saving the system log here. If necessary, click Browse to find a suitable folder.
9.4Encoder
Encoder
>Privacy Masks
>Encoder Profile
>Encoder Streams
>Audio
9.4.1Privacy Masks
Four privacy mask areas can be defined. The activated masked areas are filled with the selected pattern in live view.
1.Select the pattern to be used for all masks (Gray).
2.Check the box of the mask you wish to activate.
3.Use the mouse to define the area for each of the masks.
9.4.2Encoder Profile
Adapt the video data transmission to the operating environment (network structure, bandwidth, data structures). The camera simultaneously generates two H.264 video streams and an
Define profiles
Eight definable profiles are available. The
???High resolution 1
High resolution (4CIF/D1) for high bandwidth connections
???High resolution 2
High resolution (4CIF/D1) with lower data rate
???Low bandwidth
High resolution (4CIF/D1) for low bandwidth connections
???DSL
High resolution (4CIF/D1) for DSL connections at 500 kbps maximum
???ISDN (2B)
CIF resolution for ISDN connections at 100 kbps maximum
???ISDN (1B)
CIF resolution for ISDN connections at 50 kbps maximum
???MODEM
CIF resolution for analog modem connections at 22 kbps maximum
???GSM
CIF resolution for GSM connections
Profile Configuration
Profiles can be configured for use with the H.264 settings of encoder streams. Select a profile by clicking the appropriate tab. Change the name of a profile and individual parameter values within a profile.
Profiles are rather complex. They include a number of parameters that interact with one another, so it is generally best to use the default profiles. Only change a profile if completely familiar with all the configuration options.
The parameters as a group constitute a profile and are dependent on one another. If a setting outside the permitted range for a parameter is entered, the nearest valid value is substituted when the settings are saved.
Profile name
Enter a new name for the profile here.
Target data rate
To optimize utilization of the bandwidth in the network, limit the data rate for the camera. The target data rate should be set according to the desired picture quality for typical scenes with no excessive motion.
For complex images or frequent changes of image content due to frequent movements, this limit can temporarily be exceeded up to the value entered in the Maximum data rate field.
Maximum data rate
This maximum data rate is not exceeded under any circumstances. Depending on the video quality settings for the
The value entered here must be at least 10% higher than the value entered in the Target data rate field. If the value entered here is too low, it is automatically adjusted.
Encoding interval
The Encoding interval slider determines the interval at which images are encoded and transmitted. This can be particularly advantageous with low bandwidths. The image rate in ips (images per second) is displayed next to the slider.
Video resolution
Select the desired resolution for the video image. The following resolutions are available:
???CIF
352 ?? 288/240 pixels
???4CIF/D1
704 ?? 576/480 pixels
Expert Settings
if necessary, use the expert settings to adapt the
This setting adjusts the image quality of the
This setting adjusts the maximum image quality of the
The value 9 represents the best image quality with, if necessary, a lower frame refresh rate depending on the settings for the maximum data rate. A value of 51 results in a very high refresh rate and lower image quality.
Default
Click Default to return the profile to the factory default values.
9.4.3Encoder Streams
Select H.264 Settings
1.Select the codec algorithm for streams 1 and 2. The following algorithms are available
???H.264 BP+ (HW decoder)
???H.264 MP Low Latency
2.Select the default profile for streams 1 and 2 from the eight profiles that have been defined.
The algorithm properties have the following settings:
Preview >>
Previews of streams 1 and 2 can be shown.
1.Click Preview >> to display a preview of the video for streams 1 and 2. the current profile is shown above the preview.
2.Click 1:1 Live View below a preview to open a viewing window for that stream. Various additional items of information are shown across the top of the window.
3.Click Preview << to close the preview displays.
Note:
Deactivate the display of the video images if the performance of the computer is adversely affected by the decoding of the data stream.
JPEG stream
Set the parmeters for the
???Select the Max. frame rate in images per second (IPS).
???The Picture quality slider allows adjustment of the
Note:
The JPEG resolution follows the highest resolution setting either in stream 1 or stream 2. For example, if stream 1 is 4CIF/ D1 and stream 2 is CIF, the JPEG resolution will be 4CIF/D1.
9.5Audio
Switch the camera audio On or Off. Adjust the input and output levels with the sliders.
Note:
The audio signals are sent in a separate data stream parallel to the video data, and so increase the network load. The audio data requires an additional bandwidth of approximately
80 kbps for each connection. If you do not want any audio data to be transmitted, select Off.
9.6Camera
Camera
If the camera is in monochrome mode, all
9.6.1Mode
The camera has six
The modes are defined as follows:
1.
Default installation mode to provide stable pictures over a
2.Traffic
Capture
3.Low light
Provide extra enhancement, such as AGC and SensUp to make usable pictures in
4.Smart BLC
Settings optimized to capture details in high contrast and extremely
5.Low noise
Enhancements are set to reduce picture noise. Useful for conditional refresh DVR and IP storage systems because reducing noise reduces the amount of storage required.
6.Infrared
Use this mode if the camera is viewing a scene lit by infrared light.
These modes are
Mode ID
Enter a name for the selected mode.
Copy mode to
Select a mode to copy the current mode to.
Restore Mode Defaults
Click to restore the factory defaults. A confirmation screen appears. Allow 5 seconds for the camera to optimize the picture after a mode reset.
9.6.2ALC
ALC level
Adjust the video output level
Select the range within which the ALC will operate. A positive value is more useful for
Some ALC adjustment may improve scene content when Smart/ BLC is enabled.
Peak average
Adjust the balance between peak and average video control
A negative value gives more priority to average light levels; a positive value gives more priority to peak light levels. Video iris lens: choose an average level for best results (peak settings may cause oscillations).
Speed
Adjust the speed of the video level control loop (Slow, Medium, or Fast). For most scenes it should remain at the default value.
9.6.3Shutter/AGC
Shutter
???Fixed ??? allows a
???AES
???FL ??? flickerless mode avoids interference from light sources (recommended for use with video iris or DC iris lenses only).
Default shutter / Fixed shutter
Select the shutter speed (1/60 [1/50], 1/100, 1/120, 1/250, 1/ 500, 1/1000, 1/2000, 1/5000, 1/10K) for the default (AES) or fixed value.
In AES mode, the camera tries to maintain the selected shutter speed as long as the light level of the scene is high enough.
In Fixed mode, select the shutter speed.
Actual shutter
Displays the actual shutter value from the camera to help compare lighting levels and optimum shutter speed during set- up.
Sensitivity up
Selects the factor by which the sensitivity of the camera is increased (OFF, 2x, 3x, etc. to a maximum of 10x).
Note:
If Sensitivity up is active, some noise or spots may appear in the picture. This is normal camera behavior. Sensitivity up may cause some motion blur on moving objects.
Gain
AGC - the camera automatically sets the gain to the lowest possible value needed to maintain a good picture.
Fixed - sets Fixed gain value.
Maximum gain / Fixed gain
Selects the maximum value the gain can have during AGC operation (0 to 30 dB).
Selects the gain setting for Fixed gain operation (0 is no gain).
Actual gain
Displays the actual AGC value from the camera to help compare gain level with lighting levels and picture performance.
9.6.4Day/night
The Day/Night camera is equipped with a motorized IR (infrared) filter. The IR filter can be removed in
???via the alarm input,
???as part of the programmable mode profile,
???automatically, based on the observed light levels, or
???via the settings page.
Day/night
Auto - the camera switches the IR
Monochrome - the IR
Color - the camera always produces a color signal regardless of light levels.
Switch level
Set the video Switch level at which the camera in Auto mode switches to monochrome operation
A low (negative) value means that the camera switches to monochrome at a lower light level. A high (positive) value means that the camera switches to monochrome at a higher light level.
Priority
In Auto switching mode, set the camera priority to either:
???Color: the camera gives color pictures as long as the light level permits.
???Motion: the camera gives sharp images without motion blur as long as the light level permits (it switches to monochrome earlier than it would with Color priority).
The camera recognizes
IR contrast
There are two modes for IR contrast:
???Enhanced: the camera optimizes contrast in applications with high IR illumination levels. Select this mode for IR (730 to 940 nm) light sources and for scenes with grass and green foliage.
???Normal: the camera optimizes contrast in mono applications with visible light illumination.
Color burst
???Off: the color burst in the video signal is switched Off in monochrome mode.
???On: the color burst remains active even in monochrome mode (required by some DVRs and IP encoders).
9.6.5Enhance
Dynamic engine
???Off: turns off all automatic scene detail and enhancements (only recommendedfor testing).
???XF Dynamic: extra internal processing is enabled for low- light applications (traffic, etc.).
???2X Dynamic: 2X Dynamic adds dual sensor exposure to the XF Dynamic features. In harsh lighting conditions pixels
from each exposure are mixed to give a more detailed image (use 2X Dynamic when SmartBLC is not required).
???Smart BLC: BLC window and weighting factor are automatically defined. Camera dynamically adjusts these for changing light conditions. Includes all the benefits of 2X Dynamic.
Auto black
Auto black ON automatically increases the visibility of details even when scene contrast is less than
Sharpness level
Adjusts the black level between
A low (negative) value makes the picture less sharp. Increasing sharpness brings out more detail. Extra sharpness can enhance the details of license plates, facial features and the edges of certain surfaces.
Dynamic noise reduction
In AUTO mode the camera automatically reduces the noise in the picture. This may cause some motion blur on exceptionally fast moving objects immediately in front of the camera. This can be corrected by widening the field of view or selecting Off.
Peak white invert
Use Peak white invert to reduce glare from the CRT/LCD display.
Use in ANPR/LPR applications to reduce headlight glare. (Test
9.6.6Color
White balance
???ATW: Auto tracking white balance allows the camera to continually adjust for optimal color reproduction.
???AWB hold: Puts ATW on hold and saves the color settings.
???In Manual mode the Red, Green, and Blue gain can be manually set to a desired position.
Speed
Adjust the speed (Fast, Mediumor Slow) of the white balance control loop.
Offsets factory white point alignment (reducing red introduces more cyan).
ATW and AWBhold
Manual
Offsets factory white point alignment (reducing blue introduces more yellow).
ATW and AWBhold
Manual
Manual
It is only necessary to change the white point offset for special scene conditions.
Saturation
Adjusts the color saturation;
9.6.7Installer Options
Synchronization
Select the Synchronization method for the camera:
???Line lock to lock to the power supply frequency;
???Internal for free running camera operation.
Ticker bar
Switches a ticker bar on the live image on or off.
Camera buttons
Disable the Camera buttons on the camera to prevent unauthorized change of the camera settings.
Camera LED
Disable the Camera LED on the camera to switch it off.
Show test pattern
Select On to show a video test signal.
Pattern
Select the desired test pattern to help with installation and
Restore all defaults
Click Restore all defaults to restore the factory defaults for the camera. A confirmation screen appears. Allow 5 seconds for the camera to optimize the picture after a mode reset.
Note:
The default IP address is restored. Connect to the camera again using this address.
9.7Recording
Recording
>Storage Management
>Recording Profiles
>Retention Time
>Recording Scheduler
>Recording Status
Record the images from the camera to an appropriately configured iSCSI system. For
A Video Recording Manager (VRM) can control all recording when accessing an iSCSI system. The VRM is an external program for configuring recording tasks for video servers. For further information, contact your local customer service at Bosch Security Systems.
9.7.1Storage Management
Device manager
If the VRM option is activated, the VRM Video Recording Manager manages all recording and no further settings can be configured here.
Note:
Activating or deactivating VRM causes the current settings to be lost; they can only be restored through reconfiguration.
Recording media
Select the required recording media to activate them and then configure the recording parameters.
iSCSI Media
If an iSCSI system is selected as the storage medium, a connection to the desired iSCSI system is needed to set the configuration parameters.
The storage system selected must be available on the network and completely set up. Amongst other things, it must have an IP address and be divided into logical drives (LUN).
1.Enter the IP address of the required iSCSI destination in the iSCSI IP address field.
2.If the iSCSI destination is password protected, enter this into the Password field.
3.Click the Read button. The connection to the IP address is established. The Storage overview field displays the logical drives.
Activating and Configuring Storage Media
The storage overview displays the available storage media. Select individual media or iSCSI drives and transfer these to the Managed storage media list. Activate the storage media in this list and configure them for storage.
Note:
Each storage medium can only be associated with one user. If a storage medium is already being used by another user, decouple the user and connect the drive to the camera. Before decoupling, make absolutely sure that the previous user no longer needs the storage medium.
1.In the Storage overview section,
2.Click Set to activate all media in the Managed storage media list. These are indicated in the Status column by the status Online.
3.Check the box in the Rec. 1 or Rec. 2 column to specify which data stream should be recorded on the storage media selected. Rec. 1 stores stream 1, Rec. 2 stores stream 2.
4.Check the boxes for the Overwrite older recordings option to specify which older recordings can be
overwritten once the available memory capacity has been used. Recording 1 corresponds to stream 1, Recording 2 corresponds to stream 2.
Note:
If older recordings are not allowed to be overwritten when the available memory capacity has been used, the recording in question is stopped. Specify limitations for overwriting old recordings by configuring the retention time.
Formatting Storage Media
Delete all recordings on a storage medium at any time. Check the recordings before deleting and back up important sequences on the computer's hard drive.
1.Click a storage medium in the Managed storage media list to select it.
2.Click Edit below the list. A new window opens.
3.Click Formatting to delete all recordings in the storage medium.
4.Click OK to close the window.
Deactivating Storage Media
Deactivate any storage medium from the Managed storage media list. It is then no longer used for recordings.
1.Click a storage medium in the Managed storage media list to select it.
2.Click Remove below the list. The storage medium is deactivated and removed from the list.
9.7.2Recording Profiles
Define up to ten different recording profiles here, then assign these to individual days or times of day on the Recording Scheduler page. Modify the names of the recording profiles on the tabs in the Recording Scheduler page.
1.Click a tab to edit the corresponding profile.
2.If necessary, click Default to return all settings to their defaults.
3.Click Copy Settings to copy the currently visible settings to other profiles. A window opens to select the target profiles for the copied settings.
4.For each profile, click Set to save.
Stream profile settings
Select the profile setting that is to be used for each data stream when recording. This selection is independent of the selection for live data stream transmission. (The properties of the profiles are defined on the Encoder Profile page.)
Recording includes
Specify whether, in addition to video data, audio or metadata (for example alarms or VCA data) should also be recorded. Including metadata could make subsequent searches of recordings easier but it requires additional memory capacity. Without metadata, it is not possible to include video content analysis in recordings.
Standard recording
Select the mode for standard recordings:
???Continuous: the recording proceeds continuously. If the maximum memory capacity is reached, older recordings will automatically be overwritten.
???
???Off: no automatic recording takes place.
Stream
Select the data stream to be used for standard recordings. (You can select the data stream for alarm recordings separately and independently of this setting.)
Alarm recording
Select the
Select the Alarm stream to use for alarm recording. The encoding interval for alarm recording can be selected from the predefined profiles.
Alarm triggers
Select the alarm type (Alarm input/ Motion/Audio alarm /
Video loss alarm) that is to trigger a recording. Select the Virtual alarm sensors that are to trigger a recording, via RCP+ commands or alarm scripts, for example.
9.7.3Retention Time
Specify the retention times for recordings. If the available memory capacity of a medium has been used, older recordings are only overwritten if the retention time entered here has expired.
Make sure that the retention time corresponds with the available memory capacity. A rule of thumb for the memory requirement is as follows: 1 GB per hour retention time with 4CIF for complete frame rate and high image quality.
Enter the required retention time in hours or days for each recording. Recording 1 corresponds to Stream 1, Recording 2 corresponds to Stream 2.
9.7.4Recording Scheduler
The recording scheduler allows you to link the created recording profiles to the days and times at which the camera's images are to be recorded in the event of an alarm. Schedules can be defined for weekdays and for holidays.
Weekdays
Assign as many time periods (in
1.Click the profile to be assigned in the Time periods box.
2.Click a field in the table and, while holding down the left mouse button, drag the cursor across all of the fields to be assigned to the selected profile.
3.Use the right mouse button to deselect any of the intervals.
4.Click Select All to select all of the intervals to be assigned to the selected profile.
5.Click Clear All to deselect all of the intervals.
6.When finished, click Set to save the settings to the device.
Holidays
Define holidays whose settings will override the settings for the normal weekly schedule.
1.Click the Holidays tab. Days that have already been defined are shown in the table.
2.Click Add. A new window opens.
3.Select the desired date from the calendar. Drag the mouse to select a range of dates. These are handled as a single entry in the table.
4.Click OK to accept the selection(s). The window closes.
5.Assign the defined holidays to the recording profile as
described above.
Delete
1.Click Delete in the Holidays tab. A new window opens.
2.Click the date to be deleted.
3.Click OK. The selection is removed from the table and the window is closed.
4.Repeat for any other dates to be deleted.
Profile names
Change the names of the recording profiles listed in the Time periods box.
1.Click a profile.
2.Click Rename.
3.Enter the new name and click Rename again.
Activate recording
After completing configuration, activate the recording schedule and start recording. Once activated, the Recording Profiles and the Recording Scheduler are deactivated and the configuration cannot be modified. Terminate recording at any time to modify the configuration.
1.Click Start to activate the recording schedule.
2.Click Stop to deactivate the recording schedule. Recordings that are currently running are interrupted and the configuration can be modified.
Recording status
The graphic indicates the recording activity. An animated graphic is seen when recording is taking place.
9.7.5Recording Status
Details of the recording status are displayed here for information. These settings cannot be changed.
9.8Alarm
Alarm
>Alarm Connections
>VCA
>Audio Alarm
>Alarm
>Alarm Task Editor
9.8.1Alarm Connections
Select the response of the camera when an alarm occurs. In the event of an alarm, the device can automatically connect to a
Connect on alarm
Select On so that the camera automatically connects to a pre- defined IP address in the event of an alarm. Select Follows input 1 so that the device maintains the connection for as long as an alarm exists.
Number of destination IP address
Specify the numbers of the IP addresses to be contacted in the event of an alarm. The device contacts the remote locations one after the other in the numbered sequence until a connection is made.
Destination IP address
For each number, enter the corresponding IP address for the desired remote station.
Destination password
If the remote station is password protected, enter the password here.
Only ten passwords can be defined here. Define a general password if more than ten connections are required, for example, when connections are initiated by a controlling
system such as VIDOS or Bosch Video Management System. The camera connects to all remote stations protected by the same general password. To define a general password:
1.Select 10 in the Number of destination IP address list box.
2.Enter 0.0.0.0 in the Destination IP address field.
3.Enter the password in the Destination password field.
4.Set the user password of all the remote stations to be
accessed using this password.
Setting destination 10 to the
Video transmission
If the device is operated behind a firewall, select TCP (HTTP port) as the transfer protocol. For use in a local network, select
UDP.
Please note that in some circumstances, in the event of an alarm, a larger bandwidth must be available on the network for additional video images (if Multicast operation is not possible). To enable Multicast operation, select the UDP option for the Video transmission parameter here and on the Network page.
Remote port
Select a browser port, depending on the network configuration. The ports for HTTPS connections are only available if the On option in SSL encryption is selected.
Video output
If it is known which device is being used as the receiver, select the analog video output to which the signal should be switched. If the destination device is unknown, it is advisable to select the First available option. In this case, the image is placed on the first free video output. This is an output on which there is no signal. The connected monitor only displays images when an alarm is triggered. If a particular video output is selected and a split image is set for this output on the receiver, select the decoder from Decoder in the receiver that is to be used to display the alarm image. Refer to the destination device
documentation concerning image display options and available video outputs.
Decoder
Select a decoder of the receiver to display the alarm image. The decoder selected has an impact on the position of the image in a split screen.
SSL encryption
SSL encryption protects data used for establishing a connection, such as the password. By selecting On, only encrypted ports are available for the Remote port parameter. SSL encryption must be activated and configured on both sides of a connection. The appropriate certificates must also have been uploaded. Configure and activate encryption for media data (video, metadata) on the Encryption page.
Select On to automatically
Audio
Select On to transmit the audio stream with an alarm connection.
9.8.2Video Content Analyses (VCA)
The camera has integrated VCA which can detect and analyze changes in the signal using image processing algorithms. Such changes can be due to movements in the camera's field of view. Select various VCA configurations and adapt these to your application, as required. The Silent MOTION+ configuration is active by default. In this configuration, metadata is created to facilitate searches of recordings, however, no alarm is triggered.
1.Select a VCA configuration and make the required settings.
2.If necessary, click the Default button to return all settings to their default values.
Note:
If there is not enough computing power, priority is given to live images and recordings. This can lead to impairment of the VCA system. Observe the processor load and optimize the encoder settings or the VCA settings if necessary, or turn off VCA completely.
9.8.3VCA configuration- Profiles
Configure two profiles with different VCA configurations. Save profiles on your computer's hard drive and load saved profiles from there. This can be useful if testing a number of different configurations. Save a functioning configuration and test new settings. Use the saved configuration to restore the original settings at any time.
1.Select a VCA profile and enter the required settings.
2.If necessary, click Default to return all settings to default values.
3.Click the Save... to save the profile settings to another file. A new window opens in which to specify the file name and where to save it.
4.Click Load... to load a saved profile. A new window opens in which to select the profile file and specify where to save the file.
To rename a profile:
1.To rename the file, click the icon to the right of the list field and enter the new profile name in the field.
2.Click the icon again. The new profile name is saved.
The current alarm status is displayed for information purposes.
Aggregation time (s)
Set an aggregation time of between 0 and 20 seconds. The aggregation time always starts when an alarm event occurs. It extends the alarm event by the value set. This prevents alarm events that occur in quick succession from triggering several alarms and successive events in a rapid sequence. No further alarm is triggered during the aggregation time.
The
Analysis type
Select the required analysis algorithm. By default, only Motion+ is available ??? this offers a motion detector and essential recognition of tampering.
Metadata is always created for a video content analysis, unless this was explicitly excluded. Depending on the analysis type selected and the relevant configuration, additional information overlays the video image in the preview window next to the parameter settings. With the Motion+ analysis type, for example, the sensor fields in which motion is recorded are marked with rectangles.
Note:
Additional analysis algorithms with comprehensive functions, such as IVMD and IVA, are available from Bosch Security Systems.
Motion detector
Motion detection is available for the Motion+ analysis type. For the detector to function, the following conditions must be met:
???Analysis must be activated.
???At least one sensor field must be activated.
???The individual parameters must be configured to suit the operating environment and the desired responses.
???The sensitivity must be set to a value greater than zero.
Note:
Reflections of light (from glass surfaces, etc.), lights switching on and off, or changes in the light level caused by cloud movement on a sunny day can trigger unintended responses from the motion detector and generate false alarms. Run a series of tests at different times of the day and night to ensure that the video sensor is operating as intended. For indoor surveillance, ensure constant lighting of the areas during the day and at night.
Sensitivity
Sensitivity is available for the Motion+ analysis type. The basic sensitivity of the motion detector can be adjusted for the environmental conditions to which the camera is subject. The sensor reacts to variations in the brightness of the video image. The darker the observation area, the higher the value that must be selected.
Minimum object size
Specify the number of sensor fields that a moving object must cover to generate an alarm. This setting prevents objects that are too small from triggering an alarm. A minimum value of 4 is recommended. This value corresponds to four sensor fields.
Debounce time 1 s
The debounce time prevents very brief alarm events from triggering individual alarms. If the Debounce time 1 s option is activated, an alarm event must last at least 1 second to trigger an alarm.
Selecting the area
Select the areas of the image to be monitored by the motion detector. The video image is subdivided into square sensor fields. Activate or deactivate each of these fields individually. To exclude particular regions of the camera's field of view from monitoring due to continuous movement (by a tree in the wind, for example), the relevant fields can be deactivated.
1.Click Select Area to configure the sensor fields. A new window opens.
2.If necessary, click Clear All first to clear the current selection (fields marked red).
3.
4.If necessary, click Select All to select the entire video- frame for monitoring.
5.
6.Click OK to save the configuration.
7.Click the close button (X) in the window title bar to close the window without saving the changes.
Tamper detection
Detect tampering of cameras and video cables by means of various options. Run a series of tests at different times of the day and night to ensure that the video sensor is operating as intended.
Sensitivity and Trigger delay (s) can only be changed if
Reference check is selected.
Sensitivity
The basic sensitivity of the tamper detection can be adjusted for the environmental conditions to which the camera is subject. The algorithm reacts to the differences between the reference image and the current video image. The darker the observation area, the higher the value that must be selected.
Trigger delay (s)
Set delayed alarm triggering here. The alarm is only triggered after a set time interval in seconds has elapsed and then only if the triggering condition still exists. If the original condition has been restored before this time interval elapses, the alarm is not triggered. This avoids false alarms triggered by
Global change (slider)
Set how large the global change in the video image must be for an alarm to be triggered. This setting is independent of the sensor fields selected under Select Area. Set a high value if fewer sensor fields need to change to trigger an alarm. With a low value, it is necessary for changes to occur simultaneously in a large number of sensor fields to trigger an alarm. This option allows detection, independently of motion alarms, manipulation of the orientation or location of a camera resulting from turning the camera mount bracket, for example.
Global change
Activate this function if the global change, as set with the Global change slide control, should trigger an alarm.
Scene too bright
Activate this function if tampering associated with exposure to extreme light (for instance, shining a flashlight directly on the objective) should trigger an alarm. The average brightness of the scene provides a basis for recognition.
Scene too dark
Activate this function if tampering associated with covering the objective (for instance, by spraying paint on it) should trigger an alarm. The average brightness of the scene provides a basis for recognition.
Scene too noisy
Activate this function if tampering associated with EMC interference (noisy scene as the result of a strong interference signal in the vicinity of the video lines) should trigger an alarm.
Reference check
Save a reference image that can be continuously compared with the current video image. If the current video image in the marked areas differs from the reference image, an alarm is triggered. This detects tampering that would otherwise not be detected, for example, if the camera is turned.
1.Click Reference to save the currently visible video- image as a reference.
2.Click Select Area and select the areas in the reference image that are to be monitored.
3.Check the box Reference check to activate the
4.Select the Disappearing edges or Appearing edges option to specify the reference check once again.
Disappearing edges
The area selected in the reference image should contain a prominent structure. If this structure is concealed or moved, the reference check triggers an alarm. If the selected area is too homogenous, so that concealing and moving the structure would not trigger an alarm, then an alarm is triggered immediately to indicate the inadequate reference image.
Appearing edges
Select this option if the selected area of the reference image includes a largely homogenous surface. If structures appear in this area, then an alarm is triggered.
Selecting the area
Select the image areas in the reference image that are to be monitored. The video image is subdivided into square fields. Activate or deactivate each of these fields individually.
Select only those areas for reference monitoring in which no movement takes place and that are always evenly lit, as false alarms could otherwise be triggered.
1.Click Select Area to configure the sensor fields. A new window opens.
2.If necessary, click Clear All first to clear the current selection (fields marked yellow).
3.
4.If necessary, click Select All to select the entire video- frame for monitoring.
5.
6.Click OK to save the configuration.
7.Click the close button (X) in the window title bar to close the window without saving the changes.
9.8.4VCA configuration - Scheduled
A scheduled configuration allows you to link a VCA profile with the days and times at which the video content analysis is to be active. Schedules can be defined for weekdays and for holidays.
Weekdays
Link any number of
1.Click the profile to link in the Time periods field.
2.Click in a field in the table, hold down the mouse button and drag the cursor over all the periods to be assigned to the selected profile.
3.Use the right mouse button to deselect any of the intervals.
4.Click Select All to link all time intervals to the selected profile.
5.Click Clear All to deselect all of the intervals.
6.When finished, click Set to save the settings in the device.
Holidays
Define holidays on which a profile should be active that are different to the standard weekly schedule.
1.Click the Holidays tab. Any days that have already been selected are shown in the table.
2.Click Add. A new window opens.
3.Select the desired date from the calendar. Select several consecutive calendar days by holding down the mouse button. These will later be displayed as a single entry in the table.
4.Click OK to accept the selection. The window closes.
5.Assign the individual holidays to the VCA profiles, as described above.
Deleting Holidays
Delete defined holidays at any time:
1.Click Delete. A new window opens.
2.Click the date to delete.
3.Click OK. The item is deleted from the table and the window closes.
4.The process must be repeated for deleting additional days.
9.8.5VCA configuration - Event triggered
This configuration allows you to stipulate that the video content analysis is only to be activated when triggered by an event. As long as no trigger is activated, the Silent MOTION+ configuration in which metadata is created is active; this metadata facilitates searches of recordings, but does not trigger an alarm.
Trigger
Select a physical alarm or a virtual alarm as a trigger. A virtual alarm is created using software, with RCP+ commands or alarm scripts, for example.
Trigger active
Select the VCA configuration here that is to be enabled via an active trigger. A green check mark to the right of the list field indicates that the trigger is active.
Trigger inactive
Select the VCA configuration here that is to be activated if the trigger is not active. A green check mark to the right of the list field indicates that the trigger is inactive.
Delay (s)
Select the delay period for the reaction of the video content analysis to trigger signals. The alarm is only triggered after a set time interval in seconds has elapsed and then only if the triggering condition still exists. If the original condition has been restored before this time interval elapses, the alarm is not triggered. A delay period may be useful in avoiding false alarms or frequent triggering. During the delay period, the Silent MOTION+ configuration is always enabled.
9.8.6Audio Alarm
Create alarms based on audio signals. Configure signal strengths and frequency ranges so that false alarms, for example, machine noise or background noise, are avoided. Set up normal audio transmission before configuring the audio alarm.
Audio alarm
Select On for the device to generate audio alarms.
Name
The name makes it easier to identify the alarm in extensive video monitoring systems, for example with the VIDOS and Bosch Video Management System programs. Enter a unique and clear name here.
Signal Ranges
Exclude particular signal ranges in order to avoid false alarms. For this reason the total signal is divided into 13 tonal ranges (mel scale). Check or uncheck the boxes below the graphic to include or exclude individual ranges.
Threshold
Set up the threshold on the basis of the signal visible in the graphic Set the threshold using the slide control or, alternatively, move the white line directly in the graphic using the mouse.
Sensitivity
Use this setting to adapt the sensitivity to the sound environment and effectively suppress individual signal peaks. A high value represents a high level of sensitivity.
9.8.7Alarm
As an alternative to automatic connecting, alarm states can also be documented by
Send alarm
Select On for the device to automatically send an alarm
Mail server IP address
Enter the IP address of a mail server that operates on the SMTP standard (Simple Mail Transfer Protocol). Outgoing
SMTP user name
Enter a registered user name for the chosen mail server.
SMTP password
Enter the required password for the registered user name.
Format
Select the data format of the alarm message.
???Standard (with JPEG):
???SMS:
When a cellphone is used as the receiver, make sure to activate the
Attach JPEG from camera
Check the box to specify that JPEG images are sent from the camera.
Destination address
Enter the
Sender name
Enter a unique name for the
Test
Click Send Now to test the
9.8.8Alarm Task Editor
Editing scripts on this page overwrites all settings and entries on the other alarm pages. This procedure cannot be reversed. To edit this page, you should have programming knowledge and be familiar with the information in the Alarm Task Script Language document and the English language. The document can be found on the product DVD supplied.
As an alternative to the alarm settings on the various alarm pages, enter the desired alarm functions in script form here. This will overwrite all settings and entries on the other alarm pages.
1.Click Examples under the Alarm Task Editor field to see some script examples. A new window opens.
2.Enter new scripts in the Alarm Task Editor field or change existing scripts in line with your requirements.
3.When finished, click Set to transmit the scripts to the device. If the transfer was successful, the message Script successfully parsed. is displayed over the text field. If it was not successful, an error message is displayed with further information.
9.9Interfaces
Interfaces
>Alarm input
>Relay
>COM1
9.9.1Alarm input
Configure the alarm triggers for the camera.
Select N.C. (Normally Closed) if the alarm is to be triggered by closing the contact.
Select N.O. (Normally Open) if the alarm is to be triggered by opening the contact.
Name
Enter a name for the alarm input. This is then displayed below the icon for the alarm input on the LIVEPAGE (if configured).
Action
Select the camera mode to switch to when alarm input 1 is triggered. See Section 9.8.8 Alarm Task Editor, page 100, for information on alarm actions based on alarm inputs.
9.9.2Relay
Configure the switching behavior of the relay output.
Select different events that automatically activate an output. For example, turn on a floodlight by triggering a motion alarm and then turn the light off again when the alarm has stopped.
Idle state
Select Open for the relay to operate as an N.O. contact, or select Closed if the relay is to operate as an N.C. contact.
Select
Select External device or Motion+/IVA to trigger the relay.
Relay name
The relay can be assigned a name here. The name is shown on the button next to Trigger relay. The LIVEPAGE can also be configured to display the name next to the relay icon.
Trigger relay
Click the button to switch the relay manually (for example, for testing purposes or to operate a door opener).
9.9.3COM1
Configure the data connector for the camera.
Serial port function
Select a controllable unit from the list. If you wish to use the serial port to transmit transparent data, select Transparent. Select Terminal if you wish to operate the unit from a terminal. After selecting a unit, the remaining parameters in the window are set automatically and should not be changed.
Camera ID
If necessary, enter the ID of the peripheral you wish to control (for example a dome camera or pan/tilt head).
Baud rate
Select the value for the transmission rate in bps.
Data bits
The number of data bits per character cannot be changed.
Stop bits
Select the number of stop bits per character.
Parity check
Select the type of parity check.
Interface mode
Select the desired protocol for the serial interface.
9.10Network
Network
9.10.1Network
The settings on this page are used to integrate the device into a network. Some changes only take effect after a reboot. In this case Set changes to Set and Reboot.
1.Make the desired changes.
2.Click Set and Reboot.
The device is rebooted and the changed settings are activated. If the IP address, subnet mask, or gateway address is changed, then the device is only available under the new addresses after the reboot.
Automatic IP assignment
If a DHCP server is employed in the network for the dynamic assignment of IP addresses, activate acceptance of IP addresses automatically assigned to the device.
Certain applications (VIDOS, Bosch Video Management System, Archive Player, Configuration Manager) use the IP address for the unique assignment of the device. If using these applications, the DHCP server must support the fixed assignment between IP address and MAC address, and must be appropriately set up so that, once an IP address is assigned, it is retained each time the system is rebooted.
IP address
Enter the desired IP address for the camera. The IP address must be valid for the network.
Subnet mask
Enter the appropriate subnet mask for the set IP address.
Gateway address
For the device to establish a connection to a remote location in a different subnet, enter the IP address of the gateway here. Otherwise, this field can remain empty (0.0.0.0).
DNS server address
The device is easier to access if it is listed on a DNS server. For example, to establish an Internet connection to the camera, it is sufficient to enter the name given to the device on the DNS server as a URL in the browser. Enter the DNS server's IP address. Servers are supported for secure and dynamic DNS.
Details >>
Video transmission
If the device is used behind a firewall, TCP (Port 80) should be selected as the transmission protocol. For use in a local network, choose UDP.
Multicast operation is only possible with the UDP protocol. The TCP protocol does not support multicast connections. The MTU value in UDP mode is 1514 bytes.
HTTP browser port
Select a different HTTP browser port from the list if required. The default HTTP port is 80. To limit connection to HTTPS, deactivate the HTTP port. To do this, activate the Off option.
HTTPS browser port
To limit browser access to encrypted connections, choose an HTTPS port from the list. The standard HTTPS port is 443. Select the Off option to deactivate HTTPS ports and limit connections to unencrypted ports.
The camera uses the TLS 1.0 protocol. Ensure that the browser has been configured to support this protocol. Also ensure that Java application support is activated (in the Java
To limit connections to SSL encryption, set the Off option in the HTTP browser port, the RCP+ port, and Telnet support. This deactivates all unencrypted connections allowing connections on the HTTPS port only.
Configure and activate encryption for media data (video, audio, metadata) on the Encryption page.
RCP+ port 1756
Activating RCP+ port 1756 allows unencrypted connections on this port. To allow only encrypted connections, set the Off option to deactivate the port.
Telnet support
Activating Telenet support allows unencrypted connections on this port. To allow only encrypted connections, set the Off option to deactivate telnet support, making telnet connections impossible.
Interface mode ETH
If necessary, select the Ethernet link type for interface ETH. Depending on the device connected, it may be necessary to select a special operation type.
Network MSS (Byte)
Set the maximum segment size for the IP packet's user data here. This gives the option to adjust the size of the data packets to the network environment and to optimize data transmission. Please comply with the MTU value of 1,514 bytes in UDP mode.
iSCSI MSS (Byte)
Specify a higher MSS value for a connection to the iSCSI system than for the other data traffic via the network. The potential value depends on the network structure. A higher value is only useful if the iSCSI system is located in the same subnet as the camera.
Enable DynDNS
DynDNS.org is a DNS hosting service that stores IP addresses in a database ready for use. It allows selecting the device via the Internet using a host name, without having to know the current IP address of the device. Enable this service here. To do this, obtain an account with DynDNS.org and register the required host name for the device on that site.
Note:
Information about the service, registration process and available host names can be found at DynDNS.org.
Host name
Enter the host name registered on DynDNS.org for the device here.
User name
Enter the user name registered at DynDNS.org here.
Password
Enter the password registered at DynDNS.org here.
Force registration now
Force the registration by transferring the IP address to the DynDNS server. Entries that change frequently are not provided in the Domain Name System. It is a good idea to force the registration when setting up the device for the first time. Only use this function when necessary and no more than once a day, to avoid the possibility of being blocked by the service provider. To transfer the IP address of the device, click the Register button.
Status
The status of the DynDNS function is displayed here for information purposes; these settings cannot be changed.
9.10.2Advanced
The settings on this page are used to set advanced settings the network. Some changes only take effect after a reboot. In this case Set changes to Set and Reboot.
1.Make the desired changes.
2.Click Set and Reboot.
The device is rebooted and the changed settings are activated.
SNMP
The camera supports the SNMP V2 (Simple Network Management Protocol) for managing and monitoring network components, and can send SNMP messages (traps) to IP addresses. It supports SNMP MIB II in the unified code.
If On is selected for the SNMP parameter and a SNMP host address is not entered, the device does not send the traps automatically and will only reply to SNMP requests. If one or two SNMP host addresses are entered, SNMP traps are sent automatically. Select Off to deactivate the SNMP function.
1. SNMP host address / 2. SNMP host address
To send SNMP traps automatically, enter the IP addresses of one or two target devices here.
SNMP traps
To choose which traps are sent:
1.Click Select. A dialog box appears.
2.Click the check boxes of the appropriate traps.
3.Click Set to close the window and send all of the checked traps.
Authentication (802.1x)
To configure Radius server authentication, connect the camera directly to a computer using a network cable. If a Radius server controls access rights over the network, select On to activate authentication to communicate with the device.
1.Enter the user name that the Radius server uses for the camera in the Identity field.
2.Enter the Password that the Radius server expects from the camera.
RTSP port
If necessary, select a different port for the exchange of the RTSP data from the list. The standard RTSP port is 554. Select Off to deactivate the RTSP function.
9.10.3Multicasting
In addition to a
A special IP address (class D address) must be configured for multicast operation in a
Enable
Enable simultaneous data reception on several receivers that need to activate the multicast function. To do this, check the box and then enter the multicast address.
Multicast Address
Enter a valid multicast address to be operated in multicast mode (duplication of the data stream in the network). With the
setting 0.0.0.0 the encoder for the stream operates in multi- unicast mode (copying of data stream in device). The camera supports
Duplication of data places a heavy demand on the CPU and can lead to impairment of the image quality under certain circumstances.
Port
Enter the port address for the stream here.
Streaming
Click the checkbox to activate multicast streaming mode. An activated stream is marked with a check. (Streaming is typically not required for standard multicast operation.)
Multicast packet TTL
A value can be entered to specify how long the multicast data packets are active on the network. If multicast is to be run via a router, the value must be greater than 1.
9.10.4JPEG Posting
Save individual JPEG images on an FTP server at specific intervals. If required, retrieve these images at a later date to reconstruct alarm events. JPEG resolution corresponds to the highest setting from the two data streams.
File name
Select how file names are created for the individual images that are transmitted.
???Overwrite: The same file name is always used and any existing file will be overwritten by the current file.
???Increment: A number from 000 to 255 is added to the file name and automatically incremented by 1. When it reaches 255, it starts again from 000.
???Date/time suffix: The date and time are automatically added to the file name. When setting this parameter, ensure that the date and time of the device are always set
correctly . For eample, the file snap011005_114530.jpg was stored on October 1, 2005 at 11.45 and 30 seconds.
Posting interval
Enter the interval in seconds at which the images are sent to an FTP server. Enter zero for no images to be sent.
FTP server IP address
Enter the IP address of the FTP server on which to save the JPEG images.
FTP server login
Enter your login name for the FTP server.
FTP server password
Enter the password that gives access to the FTP server.
Path on FTP server
Enter an exact path to post the images on the FTP server.
9.10.5Encryption
If an encryption license is installed, this submenu gives access to the encryption parameters.
9.11Service
Service
>Maintenance
>Licenses
>System Overview
9.11.1Maintenance
CAUTION!
Before starting a firmware update, make sure to select the correct upload file. Uploading the wrong files can result in the device no longer being addressable, requiring it to be replaced. Do not interrupt the firmware installation. Even changing to another page or closing the browser window leads to interruption. Interruption may lead to faulty coding of the Flash memory. This can result in the device no longer being addressable, requiring it to be replaced.
Firmware
The camera functions and parameters can be updated by uploading new firmware. To do this, the latest firmware package is transferred to the device via the network. The firmware is installed there automatically. Thus, a camera can be serviced and updated remotely without requiring a technician to make changes to the device on site. The latest firmware can be obtained from your customer service center or from the Bosch Security Systems download area.
To update the firmware:
1.First, store the firmware file on your hard disk.
2.Enter the full path for the firmware file in the field or click Browse to locate and select the file.
3.Click Upload to begin transferring the file to the device. The progress bar allows monitoring of the transfer.
The new firmware is unpacked and the Flash memory is reprogrammed. The time remaining is shown by the message going to reset Reconnecting in ... seconds. When the upload is completed successfully, the device reboots automatically.
If the operating status LED lights up red, the upload has failed and must be repeated. To perform the upload, switch to a special page:
1.In the address bar of your browser, enter /main.htm after the device IP address, for example: 192.168.0.10/main.htm
2.Repeat the upload.
Configuration
Save configuration data for the camera to a computer and load saved configuration data from a computer to the device.
To save the camera settings:
1.Click Download; a dialog box appears.
2.Follow the instructions to save the current settings.
To load configuration data from the computer to the device:
1.Enter the full path of the file to upload or click Browse to select the desired file.
2.Make certain that the file to be loaded comes from the same device type as the device to be reconfigured.
3.Click Upload to begin transmission to the device. The progress bar allows monitoring of the transfer.
Once the upload is complete, the new configuration is activated. The time remaining is shown by the message going to reset Reconnecting in ... seconds. When the upload is completed successfully, the device reboots automatically.
SSL certificate
To work with an SSL connection, both sides of the connection must have the appropriate certificates. Upload one or more certificate files, one at a time, to the camera.
1.Enter the full path of the file to upload or click Browse to locate the file.
2.Click Upload to start the file transfer.
Once all files have been successfully uploaded, the device must be rebooted. In the address field of the browser, enter /reset after the camera's IP address, for example:
192.168.0.10/reset
The new SSL certificate is valid.
Maintenance log
Download an internal maintenance log from the device to send it to Customer Service for support purposes. Click Download and select a storage location for the file.
9.11.2Licenses
This window is for the activation of additional functions by entering activation codes. An overview of installed licenses is shown.
9.11.3System Overview
This window is for information only and cannot be modified. Keep this information at hand when seeking technical support. Select the text on this page with a mouse and copy it so that it can be pasted into an
10 Operation via the browser
10.1Livepage
After the connection is established, the Livepage is initially displayed. It shows the live video image on the right of the browser window. Depending on the configuration, various text overlays may be visible on the live video image. Other information may also be shown next to the live video image on the Livepage. The display depends on the settings on the
LIVEPAGE Functions page.
Figure 10.1 Livepage
10.1.1Processor load
When accessing the camera with a browser, the processor load and network information is available in the upper right of the window next to the Bosch logo.
Move the mouse cursor over the icons to display numerical values. This information can help with problem solving or when fine tuning the device.
10.1.2Image selection
View the image on a full screen.
???Click the Stream 1, Stream 2 or
10.1.3View Control
If the data port is
Move the mouse cursor over the video image; additional options for controlling peripherals are displayed with the mouse cursor.
10.1.4Digital I/O
Depending on the configuration of the unit, the alarm input and the relay output are displayed next to the camera image. The alarm symbol is for information and indicates the input status of the alarm input: Active 1 = Symbol lights, Active 0 = Symbol not lit.
The relay on the camera allows the operation of a device (for example, a light or a door opener).
???To operate, click the relay symbol. The symbol is red when the relay is activated.
10.1.5System Log / Event Log
The System Log field contains information about the operating status of the camera and the connection. These messages can be saved automatically in a file. Events such as the triggering or end of alarms are shown in the Event Log field. These messages can be saved automatically in a file.
To delete the entries from the fields, click the icon in the top
10.1.6Saving snapshots
Individual images from the video sequence that is currently being shown on the Livepage can be saved in JPEG format on the computer's hard drive.
116 en | Operation via the browserDinion2X IP Camera
??? Click the camera icon to save single images.
The storage location depends on the configuration of the camera.
10.1.7Recording video sequences
Sections of the video sequence that is currently being shown on the Livepage can be saved on the computer's hard drive. The sequences are recorded at the resolution specified in the encoder configuration. The storage location depends on the configuration of the camera.
1.Click the recording icon to record video sequences.
???Saving begins immediately. The red dot on the icon indicates that a recording is in progress.
2.Click the recording icon again to stop recording.
Play back saved video sequences using the Player from
Bosch Security Systems.
10.1.8Running recording program
The hard drive icon below the camera images on the Livepage changes during an automatic recording.
The icon lights up and displays a moving graphic to indicate a running recording. If no recording is taking place, a static icon is displayed.
10.1.9Audio communication
Audio can be sent and received via the Livepage if the active monitor and the remote station of the camera support audio.
1.Press and hold the F12 key to send an audio signal to the camera.
2.Release the key to stop sending audio.
All connected users receive audio signals sent from the camera but only the user who first pressed the F12 key can send audio signals; others must wait for the first user to release the key.
10.2Recordings page
Access the Recordings page for playing back recorded video sequences from the Livepage as well as from the Settings menu. The Recordings link is only visible if a storage medium has been selected.
1.Click Recordings in the navigation bar in the upper section of the window. The playback page appears and playback begins immediately.
2.Select Recording 1 or 2 in the
10.2.1Controlling playback
A time bar below the video image allows quick orientation. The time interval associated with the sequence is displayed in the bar in gray. A green arrow above the bar indicates the position of the image currently being played back within the sequence.
The time bar offers various options for navigation in and between sequences.
???Change the time interval displayed by clicking the plus or minus icons. The display can span a range from two months to a few seconds.
???If required, drag the green arrow to the point in time at which the playback should begin.
???Red bars indicate the points in time where alarms were triggered. Drag the green arrow to navigate to these points quickly.
Control playback by means of the buttons below the video image. The buttons have the following functions:
Start/Pause playback
Jump to start of active sequence or to previous sequence
Jump to start of the next video sequence in the list
Slide control
Continuously select playback speed by means of the speed regulator:
Bookmarks
In addition, set markers in the sequences,
Jump to the previous bookmark
Set bookmark
Jump to the following bookmark
Bookmarks are only valid while in the Recordings page; they are not saved with the sequences. All bookmarks are deleted when you leave the page.
Trick mode
View recordings frame by frame in trick mode by using a mouse with a scroll wheel. To do this, place the mouse cursor in the timeline below the timescale and turn the scroll wheel. Playback is automatically stopped (paused) during scrolling. Trick mode requires significantly higher memory capacity and computing power.
11 Troubleshooting
11.1Function test
The camera offers a variety of configuration options. Therefore, check that it works properly after installation and configuration. This is the only way to ensure that the camera will function as intended in the event of an alarm.
Your check should include the following functions:
???Can the camera be called up remotely?
???Does the camera transmit all the data required?
???Does the camera respond as desired to alarm events?
???Is it possible to control peripheral devices, if necessary?
11.2Resolving problems
The following table is intended to help identify the causes of malfunctions and correct them where possible.
11.3Customer service
If a fault cannot be resolved, please contact your supplier or system integrator, or go directly to Bosch Security Systems Customer Service.
The version numbers of the internal processors can be viewed on a special page. Please note this information before contacting Customer Service.
1.In the address bar of your browser, after the unit IP address, enter: /version
for example: 192.168.0.80/version
2.Write down the information or print out the page.
12 Maintenance
12.1Testing the network connection
The ping command can be used to check the connection between two IP addresses. This allows testing whether a device is active in the network.
1.Open the DOS command prompt.
2.Type ping followed by the IP address of the device.
If the device is found, the response appears as " Reply from ... ", followed by the number of bytes sent and the transmission time in milliseconds. Otherwise, the device cannot be accessed via the network. This might be because:
???The device is not properly connected to the network. Check the cable connections in this case.
???The device is not correctly integrated into the network. Check the IP address, subnet mask, and gateway address.
12.2Communication with Terminal Program
Data Terminal
If a camera cannot be found in the network or the connection to the network is interrupted, you can connect a data terminal to the camera for initial setup and for setting important parameters. The data terminal consists of a computer with a terminal program.
You require a serial transmission cable with a
HyperTerminal, a communications accessory included with Microsoft Windows, can be used as the terminal program.
1.Disconnect the camera from the Ethernet network before working with the terminal program.
2.Connect the serial interface of the camera using any available serial interface on the computer.
Configuring the Terminal
Before the terminal program can communicate with the camera, the transmission parameters must be matched. Make the following settings for the terminal program:
???19,200 bps
???8 data bits
???No parity check
???1 stop bit
???No protocol
Command Inputs
After the connection has been established, you must log on to the camera to access the main menu. Other submenus and functions can be accessed using the
1.If necessary, turn off the local echo so that entered values are not repeated on the display.
2.Enter one command at a time.
3.When you have entered a value, such as the IP address, check the characters you have entered before pressing Enter to transfer the values to the camera.
Assigning an IP Address
Before you can operate a camera in your network you must first assign it an IP address that is valid for your network.
The following default address is preset at the factory:
192.168.0.1
1.Start a terminal program such as HyperTerminal.
2.Enter the user name service. The terminal program displays the main menu.
3.Enter command 1 to open the IP menu.
4.Enter 1 again. The terminal program displays the current IP address and prompts you to enter a new IP address.
5.Enter the desired IP address and press Enter. The terminal program displays the new IP address.
6.Use the displayed commands for any additional settings you require.
Note:
You must reboot to activate the new IP address, a new subnet mask or a gateway IP address.
Reboot
Briefly interrupt the power supply to the camera for a reboot (disconnect the power supply unit from the mains supply and switch on again after a few seconds).
Additional Parameters
You can use the terminal program to check other basic parameters and modify them where necessary. Use the on- screen commands in the various submenus to do this.
12.3Repairs
CAUTION!
Never open the casing of the unit. The unit does not contain any user serviceable parts. Ensure that all maintenance or repair work is performed only by qualified personnel (electrical engineering or network technology specialists). In case of doubt, contact your dealer's technical service center.
12.3.1Transfer and disposal
The camera should only be passed on together with this installation guide. The unit contains environmentally hazardous materials that must be disposed of according to law. Defective or superfluous devices and parts should be disposed of professionally or taken to your local collection point for hazardous materials.
13 Technical Data
13.1Specifications
13.1.2Accessories
Recommended lenses
LTC 3364/21 Varifocal Lens IR corrected
???
???
???
???
???
???
Power transformers
???120 VAC, 60 Hz, 24 VAC, 10 VA Out
???120 VAC, 60 Hz, 24 VAC, 30 VA Out
???120 VAC, 60 Hz, 24 VAC, 50 VA Out
???220 VAC, 50 Hz, 24 VAC, 20 VA Out
???220 VAC, 50 Hz, 24 VAC, 50 VA Out
Contact your Bosch representative for the latest available accessories.
Glossary
0???9
authentication and authorization in
132 en | GlossaryDinion2X IP Camera
134 en | GlossaryDinion2X IP Camera
P
Parameters Values used for configuration.
Q
R
RADIUS serverRemote Authentication
RFC 868 A Request For Comment protocol for synchronizing computer clocks over the Internet.
RS232/RS422/RS485 Recommended standards for serial data transmission. A communication interface for third party control, firmware upgrades, and service purposes for camera and DVR products.
RTP Realtime Transport Protocol: a transfer protocol for
Bosch Security Systems
www.boschsecurity.com
?? Bosch Security Systems, 2010