UPS Uninterruptible Power Supply User Manual
Important Safety Instructions
Thank you for purchasing the Belkin Uninterruptible Power Supply (UPS). It will provide you with the best protection for your connected equipment.
Please read this manual!
This manual provides safety, installation, and operating instructions that will help you obtain the highest performance and service life that the UPS has to offer.
Please save this manual!
It includes important instructions for the safe use of this UPS and for obtaining factory service should the proper operation of the UPS come into question.
Please save or recycle the packaging materials!
The UPS shipping materials were designed with great care to provide protection from
Responsible Party:
Introduction
Have you ever noticed your lights dim or flicker when you turn on your dishwasher or
A brownout is a period of insufficient
Effects: A brownout can deprive a computer of the power it needs to function, causing unwanted damage to your computer, such as frozen keyboards and hard drive crashes. Such problems will cause you to incur computer repairs, lost data, and downtime.
Solution: A Belkin Uninterruptible Power Supply (UPS) with Automatic Voltage Regulation (AVR). Typical
Only a Belkin UPS with AVR can give your computer clean and consistent power at all times.
Note: There is no guarantee that interference to radio/TV will not occur in a particular installation. If this UPS causes interference to radio or television reception (this can be determined by turning the UPS power off and on), the user is encouraged to try to correct the interference by one or more of the
following measures:
???Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
???Increase the separation between the equipment and the receiver.
???Reorient or relocate the receiving antenna.
Safety
CAUTION! To reduce the risk of electric shock, disconnect the UPS from the main power supply before installing a computer interface signal cable. Reconnect the power cord only after signaling interconnections have been made. CAUTION! The internal energy source (the battery) cannot be
CAUTION! (RISK OF ELECTRIC SHOCK) HAZARDOUS LIVE PARTS
INSIDE THIS UNIT ARE ENERGIZED FROM THE BATTERY SUPPLY EVEN WHEN
THE INPUT AC POWER IS NOT CONNECTED.
CAUTION! (RISK OF ELECTRIC SHOCK) DO NOT REMOVE COVER. NO
USER SERVICEABLE PARTS INSIDE, PLEASE REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.
WARNING: TO REDUCE THE RISK OF FIRE, ONLY REPLACE THE
FUSE WITH THE SAME TYPE AND RATING.
Presentation
FRONT PANEL
Different LEDs on the front panel will signal information when various conditions occur:
???If UPS is in
3.4ON/OFF/TEST/SILENCE BUTTON
Press the button more than 3 seconds to turn the UPS on or off, press the button less than 3 seconds to activate the UPS
REAR PANEL
3.5INTERFACE PORT
Provides both USB or RS232 (depending on model) to relay the signal to support DOS??, Windows??, and other operating systems.
Presentation (continued)
REAR PANEL (continued)
3.6TELEPHONE/FAX/MODEM OR
Telephone/Fax/Modem lines are surge protected and provide complete safety for Internet connection. One input and two outputs allow for two devices to be protected (i.e. modem and fax).
3.7BATTERY REPLACE DOOR
3.8SITE WIRING FAULT INDICATOR
The Site Wiring Fault LED will illuminate when one of the following conditions exist:
1.Open or
2.Hot and neutral polarity reversal
3.Overloaded neutral circuit
3.9AC INPUT POWER RECEPTACLE
3.10AC BREAKER (CIRCUIT BREAKER)
The circuit breaker button will stick out if an overload condition forces the UPS to disconnect itself from utility power. If the button sticks out, disconnect
3.11BATTERY
3.12
Equipment such as a printer, fax machine, scanner, or desk lamp should be powered by these outlets. These outlets do not provide power during a power outage. These outlets are always on (when utility power is available) and are not controlled by the front panel switches.
Installation
4.0Inspection
Inspect the UPS upon receipt. The packaging is recyclable; save it for reuse or dispose of it properly.
4.1Placement
Install the UPS in a protected area with adequate air flow and free of excessive dust. Do not operate the UPS where the temperature and humidity are beyond the specified limits.
4.2Connect Computer Interface
Belkin Sentry Bulldog Shutdown Management Software and the USB or RS232 DB9 cable (depending on model) can be used with this UPS. If used, connect the interface cable to the computer interface port on the back panel of the UPS and then connect to the USB or Serial port on your PC.
4.3Connect to Utility
Connect the AC input power connector to utility power to power up the UPS.
4.4Charge the Battery
The UPS charges its battery whenever it is connected to the utility power. For best results, charge the battery for 4 hours prior to initial use.
4.5Connect the Loads
Plug the loads into the output connectors on the rear of the UPS. To use the UPS as a master on/off switch, make sure all of the loads are switched on.
4.6Cable Management
It is used to corral all of the power cords into a neat and safe order. It also assists in preventing accidental cord detachment.
CAUTION: Never connect a laser printer or scanner to the backup outlets of the UPS with other computer equipment. A laser printer or scanner periodically draws significantly more power when in use than when idle. This may overload the UPS.
4.7Connect the Telephone/Fax/Modem Lines
Connect a
Note: This connection is optional but highly suggested as telephone/fax/modem lines often carry dangerous surges and spikes. The UPS works properly without a telephone/fax/modem connection.
CAUTION: The telephone/fax/modem protection feature could be rendered inoperable if improperly installed. Make sure that the telephone line from the wall is plugged into the connector marked "IN", and the device to be protected (telephone/fax/modem) is plugged into the connector marked "OUT".
CAUTION: This
Operation
5.0Switch On
With the UPS plugged in, press and hold the on/off/test/silence button for more than 3 seconds until the
The UPS will perform
Note: The UPS maintains the battery charge when in the off position and will respond to commands received through the computer interface port.
5.1Switch Off
Press and hold the on/off/test/silence button for more than 3 seconds until the
5.2
Use the
Operation (continued)
Note: During the
The
5.3SILENCE
In "
Note: In
Alarm
6.0
When in
6.1LOW BATTERY (rapid alarm)
In
6.2OVERLOAD (continuous alarm)
When the UPS is overloaded (the connected loads exceed the maximum rated capacity), the UPS emits a continuous alarm to warn of an overload condition. Disconnect nonessential equipment from the UPS to eliminate the overload.
6.3FAULT (30 seconds continuously)
When the output is shorted, the UPS emits a
Disconnect the equipment from the UPS prior to checking the equipment.
Software Options
7.0Belkin Sentry Bulldog Shutdown Management Software
Belkin Sentry Bulldog Shutdown Management Software receives communication through the USB or RS232 interface port (depending on model) to perform monitoring functions, and also provide an orderly shutdown of the computer in the event of a power failure. Moreover, Belkin Sentry Bulldog Shutdown Management Software displays all of the diagnostic symptoms on screen, such as Voltage level, Frequency, Battery level, etc.
The software is available for Windows?? 95, Windows?? 98, Windows NT?? V4 or higher, and Windows?? 2000.
7.1Interface Kits
Each interface kit includes a special interface cable which is required to convert status signals from the UPS into signals that the individual operating system can recognize. The interface cable must be connected to the USB or RS232 port (depending on model) on the UPS. The other side of the interface cable can be connected to the USB or RS232 port (depending on model) of your PC. For other installation instructions and features, please refer to the README file.
CAUTION:
Use only a factory supplied or authorized UPS monitoring cable!
7.2USB (Universal Serial Bus): HID (Human Interface Device) setup procedure
1. When the USB cable that comes with the UPS is first connected to a USB port on your computer, the Windows?? 98 dialog called ???ADD NEW HARDWARE WIZARD??? should appear automatically.
(To display this dialog manually, you can choose the Start button and then ???Settings??? to access the Control Panel and then
2.The ???ADD NEW HARDWARE WIZARD??? dialog box guides you through the installation process. Click ???Next???.
3.A dialog states "Windows will now search for any new
4.A subsequent dialog gives you these options:
???Search for the best driver for your device (recommended).
???Display a list of all drivers in specific location, so you can select the driver you want.
Please accept the recommended choice by clicking ???Next???.
5.The Wizard will then search your hard drive for a file called???.\INF\hiddev.inf. This file contains all the information that Windows?? 98 needs to install the correct device drivers.
6.At this point the wizard might ask for the Windows?? 98
7.The installation process will continue automatically until a dialog displays indicating that the drivers have been installed. Select the ???Finish??? button and your drivers are installed.
USB Interface Port
The computer interface port has the following characteristics:
1.
2.
3.USB Port Protection
4.
5.1.5 Mbps
6.Compliant with USB Specification Version 1.0
7.Compliant with HID Specification Version 1.0
8.Compliant with HID Power Device Class Version 1.0
9.Display UPS Status Data:
Voltage
10.Measurement Items:
AC Input Voltage/AC Output Voltage/AC Input Frequency/AC Output Frequency Battery Voltage/Battery Capacity/Temperature Percent Load
11.Control Items:
Turn On/Off Outlet/Schedule Shutdown/High/Low Transfer Voltage/Battery Test Delay Before Shutdown/Delay Before Startup/Delay Before Reboot
UPS Uninterruptible Power Supply User Manual
USB Interface Port
RS232 Interface Port
*pin2: PC receives line RS232 data from UPS.
*pin3: PC transmits line RS232 data to UPS.
*pin5: signal ground.
*other: not used.
The RS232 communication port provides the following features:
1. Monitoring charger status
2. Monitoring battery status and condition
3. Monitoring inverter status
4.Monitoring UPS status
5.Monitoring the utility status
6.Providing the power switch function for the computer to turn on/off the utility on schedule. To save power, UPS data will be provided at 2400 baud rate and is made up of
Battery Replacement
The average life of a battery is
EcoPower Battery Replacement Program???
In the event that the UPS needs a battery replacement, Belkin offers its EcoPower Battery Replacement Program???. This program offers a battery replacement and full service check on your UPS to ensure it is working properly to protect your connected devices. It also ensures that the battery in the UPS is discarded properly in an effort to keep our environment clean. All participants in the program will receive a
Battery Replacement
Battery replacement is a safe procedure. You may leave the UPS On and equipment connected during this procedure. Do not replace the battery when the UPS is ???On Battery???. See page 15 for diagram illustrations.
1.Set the UPS at the edge of a table (Diagram A).
2.Slide the battery compartment cover down (Diagram B).
3.Grasp the tab attached to the battery and slide the battery partially out. Then grab the battery firmly and remove; the battery wires will disconnect as the battery is pulled out (Diagram C).
4.Carefully insert the new battery halfway into the UPS. Avoid pinching the wires (Diagram D).
5.Connect the wires to the new battery according to the following configuration:
Red wire to red terminal Black wire to black terminal
6.Carefully insert the battery terminals.
7.Slide the battery compartment cover back into place (Diagram E).
The old battery must be recycled. Deliver the battery to an appropriate recycling facility or return it to Belkin in the packing carton that came with your new battery. Additional recycling information is provided with your new battery.
Battery Replacement (continued)
Troubleshooting
Storage
11.0Storage Conditions
Store the UPS covered and upright in a cool, dry location, with its battery fully charged. Before storing, charge the UPS for at least 4 hours. Disconnect any cables connected to the computer interface port to avoid unnecessary drainage of the battery.
11.1Extended Storage
During extended storage in environments where the ambient temperature is
During extended storage in environments where the ambient temperature is +30??C to +45??C, charge the UPS battery every 3 months.
Specifications (USB Series)
CE Declaration of Conformity
We, Belkin Components, declare under our sole responsibility that the F6C325u- 220V,
Belkin Components
Belkin Components warrants this product against defects in materials and workmanship for two years. If a defect is discovered, Belkin will, at its option, repair or replace the product at no charge, provided it is returned during the warranty period, with transportation charges prepaid, to the authorized Belkin dealer from whom you purchased the product. Proof of purchase may be required.
This warranty does not apply if the product has been damaged by accident, abuse, misuse, or misapplication; if the product has been modified without the written permission of Belkin; or if any Belkin serial number has been removed or defaced.
THE WARRANTY AND REMEDIES SET FORTH ABOVE ARE EXCLUSIVE IN LIEU
OF ALL OTHERS, WHETHER
ORAL OR WRITTEN, EXPRESSED OR IMPLIED. BELKIN SPECIFICALLY
DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, INCLUDING, WITHOUT
LIMITATION, WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE.
No Belkin dealer, agent, or employee is authorized to make any modification, extension, or addition to this warranty.
BELKIN IS NOT RESPONSIBLE FOR SPECIAL, INCIDENTAL, OR
CONSEQUENTIAL DAMAGES RESULTING FROM ANY BREACH OF WARRANTY,
OR UNDER ANY OTHER LEGAL THEORY, INCLUDING BUT NOT LIMITED TO
LOST PROFITS, DOWNTIME, GOODWILL, DAMAGE TO OR REPROGRAMMING,
OR REPRODUCING ANY PROGRAM OR DATA STORED IN OR USED WITH
BELKIN PRODUCTS.
Specifications
RS232 Series
USB Series