by

Thank you for selecting American Standard - the benchmark of fine quality for over 100 years. To ensure this product is installed properly, please read these instructions carefully before you begin. (Certain installations may require professional help.) Also be sure your installation conforms to local codes.

! CAUTION: PRODUCT IS FRAGILE. TO AVOID BREAKAGE AND POSSIBLE INJURY HANDLE WITH CARE!

NOTE: Pictures may not exactly define contour of china and components.

RECOMMENDED TOOLS AND MATERIALS

1REMOVE OLD TOILET

a.Close toilet supply valve and flush tank completely. Towel or sponge remaining water from tank and bowl.

b.Disconnect and remove supply line. NOTE: If replacing valve, first shut off main water supply!

c.Remove old mounting hardware, remove toilet and plug floor waste opening to prevent escaping sewer gases.

d.Remove closet bolts from flange and clean away old wax, putty, etc. from base area. NOTE: Mounting surface must be clean and level before new toilet is installed!

S A V E F O R F U T U R E U S E

730517-100

BOLT CAP

CLOSET FLANGE

CLOSET BOLT

WASHER NUT

INSTALL TOILET

a.Position toilet squarely to wall and, with a rocking motion, press bowl down fully on wax ring and flange. Alternately tighten nuts until toilet is firmly seated on floor.

! CAUTION:

DO NOT OVERTIGHTEN NUTS

OR BASE MAY BE DAMAGED!

b.Install caps on washers. (If necessary, cut bolt height to size before installing caps.)

c.Smooth off the bead of sealant around base. Remove excess sealant.

WASHER

NUT

INSTALL TANK

a.Install large rubber gasket over threaded outlet on bottom of tank and lower tank onto bowl so that tapered end of gasket fits evenly into bowl water inlet opening, and tank mounting bolts go through mounting holes. Secure with metal washers and nuts.

b.With tank parallel to wall, alternately tighten nuts until tank is snugged down evenly against bowl surface.

! CAUTION:

DO NOT OVERTIGHTEN NUTS MORE

THAN REQUIRED FOR A SNUG FIT!

With correct washers in place (see Step 9a), tighten COUPLING NUT 1/4 turn beyond hand tight. DO NOT

OVERTIGHTEN.

11

Turn on water supply. Adjust water to desired level by squeezing water level adjustment clip and moving FLOAT CUP up or down along stainless steel link.

12 CARE AND CLEANING

When cleaning your toilet, wash it with mild, soapy water, rinse thoroughly with clear water and dry with a soft cloth. Avoid detergents, disinfectants, or cleaning products in aerosol cans. NEVER use abrasive scouring powders or abrasive pads on your toilet seat. Some bathroom chemicals and cosmetics may damage the seat's finish.

! WARNING: Do not use in-tank cleaners. Products containing chlorine (calcium hypochlorite) can seriously damage fittings in the tank. This damage can cause leakage and property damage.

American Standard shall not be responsible or liable for any tank fitting damage caused by the use of cleaners containing chlorine (calcium hypochlorite).

REPAIR PARTS LIST

Repair parts are determined by toilet tank number which can be found marked inside tank.

NOTE: "XXX" represents color or trim finish options. Specify when ordering.

TROUBLESHOOTING GUIDE

CORRECTIVE ACTION

a.Open valve and allow water to fill tank.

b.Shut off water supply, disconnect supply line, and inspect

all gaskets and washers. Reassemble. Also, see Fluidmaster maintenance (see step 13).

c.Readjust chain length as required.

d.Shut off water supply. Remove cap and clean per Step 13.

a.Check that refill tube is connected to water control and inserted into tank overflow without being kinked or damaged.

b.Open supply valve fully. Be sure that proper supply tube size is used.

c.Remove obstruction. Consult a plumber if necessary.

d.Normal supply pressure must be at least 20 psi.

a.Review Step 9 of installation procedure.

b.Review Step 4 through 7 of installation procedure.

a.Readjust chain length as needed. Review step 10.

b.Replace flapper/flush valve assembly, as needed.

c.Shut off water supply. Remove cap and clean per Step 13.

AMERICAN STANDARD ONE-YEAR LIMITED WARRANTY

If inspection of this American Standard plumbing product, within one year after its initial purchase, confirms that it is defective in materials or workmanship, American Standard will repair or, at its option, exchange the product for a similar model.

This warranty does not apply to local building code compliance. Since local building codes vary considerably, the purchaser of this product should check with a local building or plumbing contractor to insure local code compliance before installation.

This warranty shall be void if the product has been moved from its initial place of installation; if it has been subjected to faulty maintenance, abuse, misuse, accident or other damage; if it was not installed in accordance with American Standard's instructions; or if it has been modified in a manner inconsistent with the product as shipped by American Standard.

American Standard's option to repair or exchange the product under this warranty does not cover any labor or other costs of removal or installation, nor shall American

Standard be responsible for any other incidental or consequential damages attributable to a product defect or to the repair or exchange of a defective product, all of which are expressly excluded from this warranty. (Some states or provinces do not allow the exclusion or limitation of implied warranties, so this exclusion may not apply to you.)

This warranty gives you specific legal rights. You may have other statutory rights that vary from state to state or from province to province, in which case this warranty does not affect such statutory rights.

For service under this warranty, it is suggested that a claim be made through the contractor or dealer from or through whom the product was purchased, or that a service request (including a description of the product model and of the defect) be sent to the following address:

In the United States:

American Standard Inc.

P.O. Box 6820

Piscataway, New Jersey 08855

Attention: Director of Consumer Affairs

For residents of the United States, warranty information may also be obtained by calling the following toll free number: (800) 223-0068