AT&T 585-300-903

Issue 4

October 1992

AUDIX??

Networking

Copyright ?? 1992 AT&T

All Rights Reserved

Printed in U.S.A.

Notice

While reasonable efforts were made to ensure that the information in this document was complete and accurate at the time of printing, AT&T can assume no responsibility for any errors. Changes and corrections to the information contained in this document may be incorporated into future reissues.

Your Responsibility for Your System's Security

You are responsible for the security of your system. AT&T does not warrant that this product is immune from or will prevent unauthorized use of common-carrier telecommunication services or facilities accessed through or connected to it. AT&T will not be responsible for any charges that result from such unauthorized use. Product administration to prevent unauthorized use is your responsibility and your system administrator should read all documents provided with this product to fully understand the features available that may reduce your risk of incurring charges.

Federal Communications Commission Statement Part 15: Class A Statement. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio-frequency energy and, if not installed and used in accordance with the instruction manual, may cause interference to radio communications. Operation of this equipment in a residential area is likely to cause interference, in which case the user at his/her own expense will be required to take whatever measures may be requiured to correct the interference.

Part 68: Network Registration Number. This equipment is registered with the FCC in accordance with Part 68 of the FCC Rules. It is identified by FCC registration number AS593M-14695- MA-E.

Trademarks

DEFINITY?? is a registered trademark of AT&T.

AUDIX?? is a registered trademark of AT&T.

Refer to the Trademarks and Service Marks section near the front of this manual for additional trademarks.

Ordering Information

The ordering number for this document is 585-300-903. To order this document, call the AT&T

Customer Information Center at 1-800-432-6600 (In Canada, use 1-800-255-1242). For more information about AT&T documents, refer to the Business Communications

Systems Publications Catalog (555-000-010).

Comments

To comment on this document, return the comment card at the front of the document.

Acknowledgment

This document was prepared by the BCSystems Product Documentation Development Department in Denver, CO.

Contents

________________________________________________________________________

iii

iv Contents

________________________________________________________________________________________________

________________________________________________________________________________________________

6. DCP Mode 3 Networks ??? 64 Kbps

Contents v

_______________________________________________________________________________________

_______________________________________________________________________________________

vi Contents

________________________________________________________________________________________________

________________________________________________________________________________________________

Contents vii

_______________________________________________________________________________________

_______________________________________________________________________________________

viii Contents

________________________________________________________________________________________________

________________________________________________________________________________________________

Contents ix

_______________________________________________________________________________________

_______________________________________________________________________________________

Abbreviations . . . . . . . . . . . . . . . . . . . . . . . AB-1

Glossary . . . . . . . . . . . . . . . . . . . . . . . . . GL-1

x Contents

________________________________________________________________________________________________

________________________________________________________________________________________________

Contents xi

_______________________________________________________________________________________

_______________________________________________________________________________________

xii Contents

________________________________________________________________________________________________

________________________________________________________________________________________________

Contents xiii

_______________________________________________________________________________________

_______________________________________________________________________________________

xiv Contents

________________________________________________________________________________________________

________________________________________________________________________________________________

Contents xv

_______________________________________________________________________________________

_______________________________________________________________________________________

xvi Contents

________________________________________________________________________________________________

________________________________________________________________________________________________

About This Document

_______________________________________________________________________________________

_______________________________________________________________________________________

This document describes most major aspects of networking AUDIX?? Voice Messaging Systems. Its purpose is to assist any group or person involved with the implementation of an AUDIX network. If it does not contain the information you desire, please ???ll out the feedback form with your comments and send it to the originating organization.

INTENDED AUDIENCE

This document is intended for account teams, the Business Communications Systems Design Center (BCSDC), the Technical Service Center (TSC), the Sales and Technical Response Center (STRC), ???eld technicians, and hotline personnel.

PREREQUISITE SKILLS OR KNOWLEDGE

No prerequisite skills or knowledge are presumed. However, it is recommended that someone with networking experience be available to assist anyone that is new to this type of implementation.

HOW THIS DOCUMENT IS ORGANIZED

Information in this document is organized as follows.

???Chapter 1, Introduction, describes the network interfaces, an overview of how a network is implemented, and the AUDIX system requirements that pertain to any type of AUDIX network.

???Chapter 2, Dedicated EIA RS-232 Networks, provides examples and requirements when using direct cabling to transmit data between adjuncts and PCs using the Electronic Industries Association (EIA) RS-232 protocol.

???Chapter 3, Switched EIA RS-232 Networks, provides examples and requirements when using a switched connection through a modem (to a tip and ring circuit) or through a data module [to a Digital Communications Protocol (DCP) circuit] to the switch.

???Chapter 4, DCP Mode 1 Networks ??? 56 Kbps, provides examples and requirements when using AT&T???s DCP Mode 1 for interlocation data transmission.

???Chapter 5, DCP Mode 2 Networks ??? Modem Pooling, provides examples and requirements when using AT&T???s DCP Mode 2 for interlocation data transmission.

???Chapter 6, DCP Mode 3 Networks ??? 64 Kbps, provides examples and requirements when using AT&T???s DCP Mode 3 for colocated or interlocation data transmission.

xvii

xviii About This Document

________________________________________________________________________________________________

________________________________________________________________________________________________

???Chapter 7, Mixtures of RS-232 and DCP Networks, presents examples of combination networks where a single adjunct might use RS-232 and DCP or where one location uses RS-232 and another location uses DCP. Requirements are provided in earlier chapters.

???Chapter 8, EIA RS-232 Cabling, explains how to install the RS-232 interface at the AUDIX system for an RS-232 interface at the switch or for a dedicated RS-232 interface.

???Chapter 9, DCP Cabling and Administration, explains how to install and administer the DCP interface on the switch for the AUDIX system.

???Chapter 10, DCP Mode 1 Installation and Administration, brie???y describes the requirements of a switch that uses DCP Mode 1 (56 Kbps) communication between adjuncts.

???Chapter 11, DCP Mode 2 Installation and Administration, explains how to install and administer modem pooling for a switch that uses DCP Mode 2 communication between adjuncts. Both stand-alone modem pooling and modem pooling that uses the modem to control the data set (D-Lead control) are described.

???Chapter 12, DCP Mode 3 Installation and Administration, brie???y explains how to install and administer a DCP Mode 3 (64 Kbps) interface at the switch.

???Chapter 13, AUDIX System Administration, contains procedures for administering the AUDIX systems for networking. It also contains an administrator???s worksheet to help keep track of network parameters.

???Chapter 14, AUDIX Network Testing, contains procedures for testing the network links, for testing transmission between AUDIX systems, and for testing the Remote Updates feature of the AUDIX system.

???Appendix A, Network Considerations, is written for the BCSDC. Every AUDIX network order must pass through the engineering center for design and approval. Information pertains to AUDIX system requirements, trunking between the switches if the network is a remote network, and administrative requirements that must be passed on to the SIM.

???Appendix B, Sales Engineering Notes, is designed to help the branch of???ce implement an AUDIX network.

???Appendix C, AMIS Analog Networking, contains a brief description of the AMIS Analog Networking feature which is an alternative to digital networking.

This document also includes an abbreviations section, glossary, and index.

CHANGES FROM THE PREVIOUS ISSUE

The entire document has been updated to re???ect AUDIX R1V7 enhancements. Speci???c changes include:

???Network loop-around testing capability for 56 and 64 Kbps setups have been added (this is administered on the maintenance : network form).

???The automatic network connection turnaround capability and the option to send messages to non- administered recipients has been added (this is administered on the system : translation : machine : audix/amis/call delivery form).

This document has also been updated to re???ect AUDIX setups with DEFINITY Communications System Generic 3 where appropriate.

_______________________________________________________________________________________

_______________________________________________________________________________________

NOTE

In this document, the terms Generic 3i and Generic 3s refer to versions of software based on DEFINITY Generic 1 features. The term Generic 3r refers to the version of software based on DEFINITY Generic 2 features. The term Generic 3 refers to all versions of Generic 3 software (Generic 3i, Generic 3r, and Generic 3s).

CONVENTIONS USED IN THIS DOCUMENT

The following typographic conventions are used in this document:

???Information that appears on your terminal screen ??? including displays, ???eld names, prompts, and error messages ??? is shown in constant-width type. Information that you are to type just as it appears in the document is shown in constant-width bold type. For example:

In the machine name ???eld, type audix.

???Terminal keys that you press are shown in curved-edge boxes. For example, an instruction to press the return, carriage return, or equivalent key appears in this document as:

Press ENTER .

???Two or three keys that you are to press at the same time (that is, you are to hold down the ???rst key while pressing the second key and, if appropriate, the third key as well) are enclosed together, separated

by hyphens, in a curved-edge box. For example, an instruction to press and hold CTRL while typing the letter d appears in this document as:

Press CTRL-d .

???Variables for which you or the system substitute a word speci???c to your own application are shown in italic type. For example, an error message that appears on the screen with the name of your own speci???c ???lename might appear generically in this document as:

Your ???le <???lename> is formatted incorrectly.

TRADEMARKS AND SERVICE MARKS

The following trademarked products are mentioned in this document:

???5ESS?? Switch is a registered trademark of AT&T

???AUDIX?? System is a registered trademark of AT&T

???DATAPHONE?? is a registered trademark and service mark of AT&T

???DEFINITY?? Communications System is a registered trademark of AT&T

???DIMENSION?? PBX is a registered trademark of AT&T

xx About This Document

________________________________________________________________________________________________

________________________________________________________________________________________________

???ESS??? Switch is a trademark of AT&T

???Hayes?? is a registered trademark of Hayes Microcomputer Products, Inc.

???Manager??? II, Manager??? III, and Manager??? IV are trademarks of AT&T

???MERLIN?? II Communications System is a registered trademark of AT&T

???RICOH??? is a trademark of RICOH Corporation

???Telebit?? is a registered trademark of Telebit Corporation

???TELETYPE?? is a registered trademark of AT&T

RELATED RESOURCES

The following documents may be helpful when planning, ordering, installing, maintaining, and using the AUDIX network.

???AUDIX System Description (585-305-201)

???Switch Administration Guide for AUDIX Voice Messaging (585-305-505)

???AUDIX Administration (585-305-501)

???AUDIX Release 1 Version 7 Forms Reference (585-305-208)

???AUDIX Data Acquisition Package (585-302-502)

???AUDIX Maintenance for Tier I (585-305-106)

HOW TO MAKE COMMENTS ABOUT THIS DOCUMENT

The reader comment card is at the back of this document. While we have tried to make this document ???t your needs, we are interested in your suggestions for improving it and urge you to complete and return a reader comment card.

If the reader comment card has been removed from this document, please send your comments to:

AT&T Technical Publications Department

Room 22-2C11

11900 North Pecos Street

Denver, Colorado 80234

1. Introduction

_______________________________________________________________________________________

_______________________________________________________________________________________

AUDIX Networking enables an organization to transmit messages between two or more AUDIX systems, making the group of systems appear as one large system. One-Cabinet AUDIX systems, Two-Cabinet AUDIX systems, and AUDIX Large systems can be used. These systems can be located on the same site or spread out over several locations in the same or different cities. A single network can have up to 101 systems (a local system can be connected to up to 100 remote systems).

When considering adding more than one system to a single switch, keep in mind that although several systems can be networked at a single location, the systems may or may not be able to be installed as fully integrated AUDIX systems (that is, with a data link installed between the AUDIX system and the switch). The number of directly connected AUDIX adjuncts depends on the switch:

???System 75 and DEFINITY Communications System Generic 1, Generic 3i, and Generic 3s support one directly connected AUDIX system.

???System 85 R2V2 and R2V3 support up to four AUDIX adjuncts.

???System 85 R2V4 and DEFINITY Generic 2 and Generic 3r support up to eight AUDIX adjuncts.

Any additional AUDIX systems must be installed as stand-alone systems.

THE NETWORK INTERFACE

An AUDIX system provides three types of network connections, using either the Electronic Industries Association (EIA) RS-232 protocol or AT&T???s DCP. They are:

???Dedicated RS-232: AUDIX systems communicate through direct cabling. No connection to the switch is required. Communication between AUDIX systems is straight RS-232. Any channel connected in this manner cannot be shared with other adjuncts or with other AUDIX system applications. This connection requires AUDIX R1V5 or later software and a TN539 or TN539B ACCE circuit pack.

???Switched RS-232: AUDIX systems communicate through dial-up modems. Communication between systems is via analog facilities. Channels connected in this manner can be shared with other systems or with the AUDIX Call Detail Recording Package (CDR). This connection requires AUDIX R1V5 or later software and a TN539 or TN539B ACCE circuit pack.

Special Application: The RS-232 channels can be converted to DCP before entering the switch. This is done with a data module instead of the modem. This, too, is a dial-up connection; all six AUDIX network channels appear at the switch as DCP channels.

1-1

1-2 Introduction

________________________________________________________________________________________________

________________________________________________________________________________________________

NOTE

Although a total of six network channels are available on an AUDIX system, the AUDIX R1V3, R1V4, and R1V5 software limit the number of simultaneously active channels to four. To use all six channels simultaneously, an AUDIX system must have R1V6 or later software and a vintage 7 TN539 or a TN539B ACCE.

???Switched DCP: AUDIX systems communicate through dial-up DCP connections at the switch. Communication between systems can be via digital or analog facilities. DCP modes 1, 2, and 3 are supported. Channels connected in this manner can be shared with other systems for networking and for other AUDIX system applications. This connection requires AUDIX R1V3 or later software and an ACC (TN366 or TN366B) or ACCE (TN539 or TN539B) circuit pack.

NOTE

If the customer???s switch does not support the DCP interface, an AT&T DCP switch can be used to provide this interface. For local networking, this is usually done with a MERLIN?? II Communications System. (Remote networking with MERLIN II is not supported.)

The TN539 or TN539B ACCE circuit pack provides two RS-232 channels and four DCP channels. Both types are two-way communications links. The type or types of connections used depend on the location and number of AUDIX systems involved, the type of switch(es) involved, networking facilities, and whether or not the customer wants to use the Text Services Interface and/or Call Detail Recording applications.

LOCAL NETWORKING

In a local network setup, one or more AUDIX systems work with a single switch. The local system can be networked with up to 100 other remote AUDIX adjuncts. In this setup, the local system is the one to which the administration terminal the system administrator is using is connected; all other systems are considered remote. All AUDIX subscribers can be assigned the same (or no) pre???xes and separate extension numbers, or different pre???xes to distinguish among local systems.

A one-cabinet 16-port AUDIX system can provide services to up to 2000 local subscribers; a two-cabinet 32-port system can handle twice as many. When AUDIX systems are integrated into a local network, they take on the appearance of one large AUDIX system. The AUDIX systems can reside together in the same equipment room with the switch, or in different locations according to the type of connections made.

Introduction 1-3

_______________________________________________________________________________________

_______________________________________________________________________________________

REMOTE NETWORKING

In a remote network, AUDIX systems are integrated with more than one switch. The local system can be networked with up to 100 other remote AUDIX adjuncts. The local system is the one to which the administration terminal the system administrator is using is connected; all other systems are considered remote. These remote systems may be geographically distant, have different dial plans, and use different connections such as:

???Digital Service (DS1) facilities between switches

???Voice-grade (analog) facilities between switches

Any remote network can be mixed with a local network. Switches can use any public or private switched networking facility, or be a part of a Digital Communications System (DCS) network.

NETWORK PLANNING

Planning is an essential ???rst step in setting up an AUDIX network. Network administration should not be started until the local AUDIX system is running smoothly. Network planning should begin as soon as the customer decides to network their AUDIX systems.

One person (perhaps someone also serving as the administrator of one of the AUDIX machines in the network) must serve as coordinator of the network. The network coordinator must establish and maintain a good line of communication with each of the remote system administrators in order to facilitate necessary cooperation and ???ow of information. Because every AUDIX machine within the network must be administered with information about any other AUDIX machine with which it will be exchanging messages, the network coordinator must be prepared to supply each local AUDIX system administrator with the information.

AUDIX NETWORK IMPLEMENTATION

Each AUDIX system in the network requires the following. Each item is explained in some detail on the following pages:

???Speci???c releases of software.

???AUDIX Communications Controller (ACC) or AUDIX Communications Controller Enhanced (ACCE) circuit pack.

???Speci???c issues of supporting circuit packs.

???Rear connector panel and backplane modi???cations.

???New network cabling used with most types of networks. When unique cabling and equipment are required, they will be pointed out in chapters 2 through 7.

???AUDIX system translations must be added.

1-4 Introduction

________________________________________________________________________________________________

________________________________________________________________________________________________

AUDIX Software

An AUDIX network can consist of a mixture of R1V3, R1V4, R1V5, R1V6, and R1V7 systems. If desired, you may upgrade your AUDIX-L to R1V5 or upgrade your AUDIX one- or two-cabinet system to the latest software version. See the System Description manual (585-305-201) for ordering codes.

NOTE

If the network contains R1V3 or R1V4 systems, the Sending Restrictions feature cannot be used.

ACC/ACCE

The AUDIX Communications Controller (ACC) or AUDIX Communications Controller Enhanced (ACCE) is the circuit pack that provides the interconnections for AUDIX networking. It must be installed in slot 03 of a one- or two-cabinet AUDIX system and in slot 16 of an AUDIX Large Data Base Processor (DBP) carrier (J58888K).

This section describes the ACC or ACCE circuit packs currently in existence. All new AUDIX systems ordered with networking are shipped with the latest circuit pack available, currently the TN539B AUDIX Communications Controller Enhanced (ACCE). However, a new AUDIX system can be added to an existing network where the earlier TN366, TN366B, or TN539 circuit packs are used.

TN366 ACC

This circuit pack provides four DCP channels. It must be a TN366 vintage 5 or later. This circuit pack is no longer orderable, but if the customer has an older vintage and wishes to upgrade, this circuit pack is available through QPPCN 330DR (comcode 103279840). It will work with R1V3 and later software.

TN366B ACC

This circuit pack provides four DCP channels. It will work with R1V3 or later software. This circuit pack is no longer orderable (comcode 106186588).

The TN366B is a TN366 that has been enhanced for the following reasons:

???The TN366B will work with modem pools that use 7400A DSUs; the original TN366 will not.

???The TN366B will work with the MERLIN II Communications System which is used as a DCP interface for non-DCP switches; the TN366 will not.

???When a Generic 2 universal module serves as the host switch, the TN366B allows access to all four DCP channels; the TN366 does not.

Introduction 1-5

_______________________________________________________________________________________

_______________________________________________________________________________________

TN539 ACCE

This circuit pack provides four DCP channels and two RS-232 channels. It will work with R1V5 and later software. The Vintage 7 TN539 permits six simultaneously active ports. Vintage 4 and earlier of the TN539 permits four simultaneously active ports. This circuit pack is no longer orderable (comcode 103281473). It provides all the functionality of the TN366 or TN366B with the following additions:

???Multi-stage dialing

???DCP Mode 1 (56 Kbps) interface

???RS-232 interface

NOTE

Customers who implemented 56 Kbps networking using TN539 ACCE boards may wish to upgrade to the TN539B ACCE in order to take advantage of the performance improvements and loop-around testing capabilities offered on this board by R1V7 software.

TN539B ACCE

This pack replaces the TN366, TN366B, or TN539 circuit pack (comcode 106757768). It provides all the functionality of the previous networking boards as well as 56 and 64 Kbps loopback testing capabilities.

All new systems ship with a TN539B ACCE. In addition, you may wish to upgrade an earlier board to a TN539B ACCE for the following reasons:

???You have a TN366 or TN366B ACC and you wish to use the two RS-232 ports available on the TN539B.

???You have a TN366 or TN366B ACC and you wish to obtain the additional activity status information available on the maintenance : network form in R1V7 (for example, if you are using the R1V7 network turnaround feature).

???You have a TN366 or TN366B ACC or a TN539 ACCE and you wish to upgrade to a TN539B ACCE for performance reasons. A TN539B is required at both the sending and receiving machine in order to achieve increased performance.

???You have a TN539 ACCE running DCP Mode 1 (56 Kbps) connections and you wish to replace it with the TN539B in order to take advantage of the AUDIX R1V7 loop-around testing capabilities and possible performance improvements (see the previous item).

All TN539B ACCE orders (new or upgrade) include two H600-330, Group 1 null-modem adapters and one H600-331, Group 2 cable. See the System Description manual (585-305-201) for ordering codes.

1-6 Introduction

________________________________________________________________________________________________

________________________________________________________________________________________________

Other AUDIX Circuit Pack Requirements

Certain circuit packs must be present and certain other packs must be of a speci???c vintage or issue.

One-Cabinet and Two-Cabinet AUDIX System

In slot 01 of the base cabinet the AUDIX system must have the following:

??? TN506B circuit pack (comcode 105222301).

In slot 04 of the base cabinet the AUDIX system must have the following:

???TN472C vintage 2 (white wire 10-17) or later circuit pack (comcode 105474126). This is the Data Base Processor Central Processing Unit (DBP-CPU).

In slot 06 of the base cabinet the AUDIX system must have the following:

???UN160B vintage 2 or later circuit pack (comcode 105319818). This is the Data Base Processor Interface (DBPI).

AUDIX Large System

In slot 01 of the DBP carrier (J58888K) the AUDIX system must have the following:

??? TN506B circuit pack (comcode 105222301).

In slots 04-07 and 12-14 of the DBP carrier the AUDIX system must have the following:

??? TN508 (vintage 4 or higher); up to seven packs.

In slot 08 of the DBP carrier the AUDIX system must have the following:

??? TN509C circuit pack (comcode 105319286). This circuit pack is available through QPPCN 444DR.

In slot 10 of the control carrier (J58888H) the AUDIX system must have the following:

??? UN160B circuit pack (comcode 105319818).

In slot 08 of the power carrier (J58888L) the AUDIX system must have the following:

??? 495JB power converter (comcode 104016746).

Rear Connector Panel and Backplane

The network cabling requires a connector on the back of the AUDIX system cabinet. This connector must be attached to the backplane. Certain versions of the backplane require wire modi???cation.

Introduction 1-7

_______________________________________________________________________________________

_______________________________________________________________________________________

One-Cabinet and Two-Cabinet AUDIX System

For new orders, an ACC/ACCE port will be installed at the back of the AUDIX system base cabinet and wired to the backplane.

For upgrades to existing systems, check the base cabinet for an ACC D05 connector. This is a 50-pin Amphenol connector. Order the AUDIX Networking upgrade kit D181965 if this port is missing (comcode 845953108).

Rear Connector Panel and Backplane (Large)

Check the control cabinet for an ACC D06 connector. This is a 50-pin Amphenol connector.

???If the connector is missing, order the AUDIX Large Networking Upgrade kits D181757 (comcode 105308696) and D182422 (comcode 845798131).

???If the port is installed, check the label on the cable that goes from the connector to the backplane. It will probably be an ED-1E434-11, Group 373 cable. If the system is to use EIA RS-232 ports for its network, this cable must be replaced with a Group 374 cable ??? order the AUDIX Large Networking Upgrade kit D182422.

Network Cabling Common to Most Con???gurations

New AUDIX systems ordered with networking will be shipped two H600-330, Group 1 null-modem adapter cables for the RS-232 ports (see Figure 1-1, H600-330, Group 1 Special AUDIX Null-Modem Cable) and one H600-331, Group 2 breakout cable (see Figure 1-2, H600-331, Group 2 AUDIX Networking Breakout Cable).

Systems that already have networking installed may have the H600-331, Group 1 networking breakout cable rather than the H600-331, Group 2 cable (see Figure 1-3, H600-331, Group 1 AUDIX Networking Breakout Cable). However, the Group 1 cables are no longer shipped.

H600-330, Group 1 Cable

The special null-modem adapter cables are used only for dedicated RS-232 connections. Two are supplied (one for each RS-232 port).

The null-modems are unique; do not substitute standard null-modems in this application.

NOTE

1-8 Introduction

________________________________________________________________________________________________

________________________________________________________________________________________________

Figure 1-1. H600-330, Group 1 AUDIX Special Null-Modem Cable

H600-331, Group 2 Cable

All new AUDIX networking systems are shipped with one H600-331, Group 2 breakout cable. One end of the Group 2 cable is a 50-pin male Amphenol connector that connects to the ACCE on the AUDIX system. The other end of the cable has a 50-pin female Amphenol connector and two 25-pin RS-232 male connectors. See Table 1-1 for the pin assignments.

The female Amphenol connector provides access to the four DCP channels (AUDIX networking channels 1, 2, 3, and 4). The RS-232 connector A provides access to one RS-232 channel (AUDIX networking channel 5), and RS-232 connector B provides access to the other RS-232 channel (AUDIX networking channel 6).

Introduction 1-9

_______________________________________________________________________________________

_______________________________________________________________________________________

B

RS-232 25-PIN

MALE CONNECTORS

5.0 FT (1.524 M)

Figure 1-2. H600-331, Group 2 AUDIX Networking Breakout Cable

H600-331, Group 1 Cable

The H600-331, Group 1 breakout cable is no longer shipped; only an AUDIX system that is already installed will have the Group 1 networking cable. One end of this cable is a 50-pin male Amphenol connector that connects to the ACC or ACCE on the AUDIX system. The other end of the cable has two 8-pin DCP connectors and two 25-pin RS-232 male connectors. See Table 1-2 for pin assignments.

The H600-331, Group 1 DCP connector 0 provides access to two DCP channels (AUDIX networking channels 1 and 2). DCP connector 1 also provides access to two DCP channels (AUDIX networking channels 3 and 4). The two 451A adapters are shipped on the ends of connectors 0 and 1. The D8W-87 extension cords and 103A adapters must be ordered separately.

The H600-331, Group 1 RS-232 connector A also provides access to one RS-232 channel (AUDIX networking channel 5), and RS-232 connector B provides access to another RS-232 channel (AUDIX networking channel 6).

1-10 Introduction

________________________________________________________________________________________________

________________________________________________________________________________________________

451A ADAPTERS, 8-PIN

F/F (COMES WITH THE

CABLE)

PATCH TO DCP

3.0 FT

INTERFACE AT

(0.914 M)

THE CROSS-

CONNECT FIELD

MODULAR 8-PIN

103A ADAPTERS,

AMPHENOL 50-PIN8-PIN to 6-WIRE

MALE CONNECTORS

MALE CONNECTOR

A

CONNECT TO DEDICATED

OR SWITCHED RS-232

ENDPOINTS

B

RS-232 25-PIN

MALE CONNECTORS

5.0 FT (1.524 M)

Figure 1-3. H600-331, Group 1 AUDIX Networking Breakout Cable

Introduction 1-11

_______________________________________________________________________________________

_______________________________________________________________________________________

AUDIX System Administration

In order for the AUDIX system to recognize messages addressed to subscribers at other AUDIX systems, it must be administered with remote machine and remote subscriber pro???les. Dial strings, transmission intervals, connection types, and so forth must also be assigned. Each AUDIX system in the network requires this administration of each of the other systems. See Chapter 13, AUDIX System Administration.

NETWORKING ENHANCEMENTS

The AUDIX Networking feature was enhanced for R1V5, R1V6, and R1V7.

R1V5 Release

Major changes brought about by AUDIX R1V5 software and the TN539 ACCE circuit pack:

???RS-232 connectivity between AUDIX systems. Previously, only DCP was supported. To use RS-232, the AUDIX system must be running R1V5 or later software and the TN539 ACCE circuit pack is required.

???DCP Mode 1 access to a switched 56 network (that is, 56 Kbps digital transmission) is supported. The AUDIX system must be running R1V5 or later software (56 Kbps loop-around testing is not offered until R1V7). Each AUDIX system requiring access to the switched 56 network must be equipped with the TN539 or TN539B ACCE circuit pack.

???Multi-Stage Dialing is supported. This allows the use of modem pooling to provide a remote AUDIX network for a non-DCP switch. The AUDIX system must be equipped with a TN539 or TN366B circuit pack, the system must be running R1V5 or later software, and a switch supporting DCP must be on site.

???The TN539 ACCE circuit pack can be used with R1V3 and R1V4 AUDIX software, but the RS-232 ports are not available unless R1V5 or later software is used.

???The TN366 or TN366B circuit pack can be used with R1V5 or later software, but the RS-232 ports and access to 56 or 64 Kbps facilities require the TN539 or TN539B ACCE.

???A network can consist of a mixture of R1V3, R1V4, R1V5, R1V6, and R1V7 AUDIX systems. However, the Sending Restrictions feature cannot be used anywhere in a network with R1V3 or R1V4 AUDIX systems.

???Network address ranges ??? up to 16 AUDIX systems can have the same range speci???ed. The old limit (R1V3 and R1V4) is eight.

1-12 Introduction

________________________________________________________________________________________________

________________________________________________________________________________________________

R1V6 Release

Major changes brought about by AUDIX R1V6 software and the vintage 7 TN539:

???With the R1V3, R1V4, and R1V5 software releases, only four channels could be simultaneously active. AUDIX systems with R1V6 software and a vintage 7 TN539 or TN539B ACCE can use all six networking ports simultaneously (however, System 75, Generic 1, Generic 3, and MERLIN II can still only access two of the four DCP channels).

NOTE

If a customer is upgrading to R1V5 or R1V6 from an existing network, and the RS-232 channels and/or six simultaneous channels are not required, the existing TN366 or TN366B can be retained. The new TN539 can replace the old circuit pack while the cabling to the switch is left intact.

R1V7 Release

Major changes brought about by AUDIX R1V7 software and the TN539B board:

???The new TN539B ACCE board can provide faster throughput than previous networking boards for networks with heavy traf???c.

???The R1V7 software and the TN539B ACCE board permit 56 or 64 Kbps loopback testing; the serving of???ce can send data to an AUDIX port and, if the connection is up, the AUDIX system will echo the data back to the serving of???ce. See Chapter 14, AUDIX Network Testing for details.

???On R1V7 systems, the network turnaround feature can be administered. This option is activated using

the system : translation : machine : audix/amis/call delivery form; it can

be administered on a system-wide or per-machine basis.

???If network connection turnaround is implemented, the local machine will call a remote machine and do the following: notify the remote system of its updated subscriber information, request updated subscriber information from the remote system, and send voice mail and updated message status information to the remote system. Then network connection will then be turned around and the remaining events will occur: the remote system will request updated subscriber information from the local system, notify the local system of its updated subscriber information, and send voice mail and updated message status information to the local system.

???If the network turnaround feature is not implemented, the local machine will call a remote machine and do the following: notify the remote system of its updated subscriber information, request updated subscriber information from the remote system, and send voice mail and updated message status information to the remote system. The call will then be disconnected.

The network turnaround feature reduces system overhead time and long-distance charges by allowing all of these events to occur with a single call rather than two calls. If cost control from a central point is not critical, greater ef???ciency can be gained by implementing the network connection turnaround feature. The connection can only be turned around once during a single call.

2. Dedicated EIA RS-232 Networks

_______________________________________________________________________________________

_______________________________________________________________________________________

AUDIX networking can be implemented using a dedicated Electronic Industries Association (EIA) RS-232 interface. This chapter presents dedicated RS-232 con???gurations supported by AT&T. These examples show AUDIX using RS-232 at both ends. For networks with RS-232 and DCP mixed, see Chapter 7,

Mixtures of RS-232 and DCP Networks.

If your customer develops their own method, contact the Business Communications Systems Design Center (BCSDC) to make sure the method is feasible. Each of the con???gurations presented here is accompanied by the equipment required for the AUDIX systems.

NOTE

System 75, DEFINITY Generic 1, Generic 3, and MERLIN II can access only two of the four DCP channels. This is a limitation regardless of the AUDIX software used and the networking circuit pack provided. When mixing the two DCP channels with the two RS-232 channels, a maximum of four channels can be provided for these switches. An AUDIX system installed with a System 85 or a DEFINITY Generic 2 can provide access to six channels in this manner.

AUDIX R1V3, R1V4, and R1V5 software limit the number of simultaneously active channels to four. To use all six channels simultaneously, an AUDIX system must have R1V6 or later software and a TN539 vintage 7 or TN539B ACCE.

CONSIDERATIONS

If a customer is considering using dedicated RS-232 connections in their AUDIX network, keep the following in mind:

???Only local networking con???gurations are supported.

???A maximum of three AUDIX systems can be networked via this method.

???AUDIX software must be R1V5 or later.

???The customer needs a TN539 or TN539B networking board.

???This type of network can operate at speeds up to 64 Kbps (depending on distance).

GENERAL INFORMATION

Figure 2-1, Dedicated RS-232 Network of Two AUDIX Systems, shows two AUDIX systems networked using dedicated RS-232 connections. The transmission schedules (that is, the times set up for one system to connect to another for the purpose of transmitting messages) can be set so the systems will not attempt to use the channel at the same time. If they do attempt simultaneous transmissions, the system denied access

2-1

2-2 Dedicated EIA RS-232 Networks

________________________________________________________________________________________________

________________________________________________________________________________________________

to the channel will retry automatically.

Normally both RS-232 channels are required for networking. If only one channel is used, the other channel can be used for the AUDIX Call Detail Recording (CDR) feature. However, this con???guration is only appropriate for networks with low traf???c volume. If a customer chooses to use a channel for CDR, AT&T recommends running CDR only during non-peak hours, thereby leaving two ports available for networking during peak hours. See Figure 2-2, Dedicated RS-232 Network of Two AUDIX Systems and a PC (Low Traf???c Only). A switched RS-232 con???guration is always preferable for networks that do not have very low traf???c.

If another system must be added to Figure 2-1, this can be done as shown in Figure 2-3, Dedicated RS-232 Network of Three AUDIX Systems (Low Traf???c Only). If a PC is required in this case, at least one channel from each system must be converted to a switched connection. See Figure 2-4, Dedicated RS-232 Network of Three AUDIX Systems and a PC. Instead of switching cables as with con???gurations such as Figure 2-2, the PC has dial-up access to any AUDIX system in the network. There is more information on switched connections in the next section.

NOTE

Text Services and/or Call Detail Recording can be added using the DCP channels. See Chapter 4, DCP Mode 1 Networks ??? 56 Kbps, and Chapter 7, Mixtures of RS-232 and DCP Networks.

When there are more systems and/or PCs than channels, contention for the channels may occur. This situation can usually be avoided, however, by scheduling the transfer of data at different times of the day. See Chapter 13, AUDIX System Administration for details on how to set up transmission schedules. Even when contention does occur, an AUDIX system will try to establish a connection two more times. If still unable to make the connection, the AUDIX system will try again at the next scheduled interval or when the transmission queue becomes full.

RS-232

Figure 2-1. Dedicated RS-232 Network of Two AUDIX Systems

_______________________________________________________________________________________

_______________________________________________________________________________________

Figure 2-2. Dedicated RS-232 Network of Two AUDIX Systems and a PC (Low Traf???c Only)

H600-330

GROUP 1 (TWO SHOWN)

H600-330

GROUP 1

Figure 2-3. Dedicated RS-232 Network of Three AUDIX Systems (Low Traf???c Only)

2-4 Dedicated EIA RS-232 Networks

________________________________________________________________________________________________

________________________________________________________________________________________________

Figure 2-4. Dedicated RS-232 Network of Three AUDIX Systems and a PC

AUDIX REQUIREMENTS FOR DEDICATED RS-232

Each AUDIX system must be running R1V5 or later software. Each AUDIX must be equipped with a TN539 or TN539B ACCE circuit pack. The AUDIX Networking Breakout cable (H600-331, Group 2) and the special AUDIX null-modems (H600-330, Group 1) are provided with each TN539 or TN539B ordered.

Standard null-modems cannot be substituted for the AUDIX null-modems.

NOTE

_______________________________________________________________________________________

_______________________________________________________________________________________

SWITCH (OR CUSTOMER) REQUIREMENTS FOR DEDICATED RS-232

If the distance between systems is greater than 10 feet (3.05 meters), an M25A RS-232 extender cable (male-female) is required in addition to the H600-331, Group 2 cable and H600-330, Group 1 null-modems at each AUDIX system. Only one null-modem is required in each link. The extender cable is inserted on one side of the null-modem. See Figure 2-5, Dedicated RS-232 Extended Connections. This cable comes in lengths up to 50 feet (15.24 meters).

If the distance between AUDIX systems is greater than 50 feet, you can do one of two things:

???In addition to the H600-331, Group 2 cable at each AUDIX system, a pair of data sets must be inserted in place of the null-modem (see Figure 2-5). The data sets must be Z3A Asynchronous Data Units (ADU). The following equipment is required (see Figure 8-3). Two Z3A Asynchronous Data Units (ADU), two D8W-87 modular cords, two 103A adapters, one D8AM-87 crossover cord, external power on one end (400B adapter, D6AP-87 modular cord, 248B adapter, and a Model 2012D transformer), and building wire (4-wire).

Check the document(s) shipped with the data sets for the maximum distances allowed.

???The dedicated connection can be recabled as a switched connection. See Chapter 3, Switched EIA RS-232 Networks.

DATA RATES FOR DEDICATED RS-232

Data rate limitations are imposed on the RS-232 interface when certain distances are exceeded:

???At 20 feet (6.1 meters) or less, the data rate can be as high as 64 Kbps.

???At 20 to 50 feet (6.1 to 15.25 meters), the maximum data rate is 19.2 Kbps unless limited-distance modems are used. Check with the documentation shipped with the limited-distance modems.

???At more than 50 feet (15.25 meters), limited-distance modems must be used. Check with the documentation shipped with the limited-distance modems.

Con???gurations with limited-distance modems are supported only as custom work.

NOTE

2-6 Dedicated EIA RS-232 Networks

________________________________________________________________________________________________

________________________________________________________________________________________________

Figure 2-5. Dedicated RS-232 Extended Connections

3. Switched EIA RS-232 Networks

_______________________________________________________________________________________

_______________________________________________________________________________________

AUDIX networks can be implemented using a switched Electronic Industries Association (EIA) RS-232 connection. Networks can also be implemented by converting the RS-232 channels into switched Digital Communications Protocol (DCP) connections. This chapter presents supported con???gurations for both methods. The examples show an AUDIX system using RS-232 at both ends. See Chapter 7, Mixtures of RS-232 and DCP Networks, for RS-232/DCP combinations.

If your customer develops their own method, contact the Business Communications Systems Design Center (BCSDC) to make sure the method is feasible. Each of the examples presented here is accompanied by the equipment required for the AUDIX systems and for the switches the AUDIX systems serve.

CONSIDERATIONS

If a customer is considering using switched RS-232 connections in their AUDIX network, keep the following in mind:

???Local or remote networking con???gurations are supported.

???Two or more AUDIX systems can be networked via this method.

???AUDIX software must be R1V5 or later.

???The customer needs a TN539 or TN539B networking board.

???In this type of network speeds can be up to 19.2 Kbps; speeds are limited by the modems or data modules the customer chooses to use.

???The customer will need data modules or Hayes-compatible modems for each AUDIX channel to be switched.

NOTE

System 75, DEFINITY Generic 1 and Generic 3, and MERLIN II can only access two of the four AUDIX DCP channels. This is a limitation regardless of the AUDIX software used and the networking circuit pack provided. Thus, conversion of the RS-232 channels to DCP becomes of particular importance in these cases. When mixing the two DCP channels with the two RS-232 channels, a maximum of four channels can be provided for these switches. AUDIX installed with a System 85 or a DEFINITY Generic 2 can provide access to six channels in this manner.

For a System 85 or Generic 2, AUDIX R1V3, R1V4, and R1V5 software limit the number of simultaneously active channels to four. To use all six channels simultaneously with a System 85 or Generic 2, an AUDIX system must have R1V6 or later software and a TN539 vintage 7 or TN539B ACCE.

3-1

3-2 Switched EIA RS-232 Networks

________________________________________________________________________________________________

________________________________________________________________________________________________

SWITCHED RS-232 USING MODEMS

When a dedicated RS-232 network requires more than three AUDIX systems, or any time two systems are separated by a distance greater than two data sets can support, a switched RS-232 network must be formed. Modems convert the RS-232 signal into an analog signal for transmission through the switch to a colocated AUDIX system, or out of the switch across the public/private facilities to another switch.

Figure 3-1, Dedicated and Switched RS-232 Network for a Single Switch, shows four AUDIX systems serving the same switch. Notice that in this example there is a mixture of dedicated and switched connections. Incorporating two dedicated connections into this setup saves the customer the price of four modems. Whether this is a viable setup depends on the network usage between all systems.

If the network requires switched access to all RS-232 channels, the network would look like Figure 3-2,

Switched RS-232 Network for a Single Switch.

Figure 3-3, Switched RS-232 Network for Separate Locations, shows three AUDIX systems serving switches at different locations. This setup also presents a mixture of dedicated and switched connections. The assumption is that the two systems serving the same switch will have much more use for a network connection, so a dedicated connection is provided. For the occasional connection to/from the other site, a switched connection is used.

If Call Detail Recording is required, a PC can be included in a switched RS-232 network using a spare dedicated RS-232 connection or through a switched RS-232 connection. Figure 3-4, Switched RS-232 Network for Separate Locations and a PC, shows a switched connection. The PC has dial-up access to any AUDIX system in the network.

_______________________________________________________________________________________

_______________________________________________________________________________________

H600-331

GROUP 2

SWITCH

H600-331

GROUP 2

MODEM

H600-330

H600-331 GROUP 1

RS-232

GROUP 2

AUDIX

MODEM

RS-232

Figure 3-1. Dedicated and Switched RS-232 Network for a Single Switch

3-4 Switched EIA RS-232 Networks

________________________________________________________________________________________________

________________________________________________________________________________________________

AUDIX System Requirements For Switched RS-232 Using Modems

Each AUDIX system must be running R1V5 or later software. Each AUDIX system must be equipped with a TN539 or TN539B ACCE circuit pack. The AUDIX Networking Breakout cable (H600-331, Group 2) is required at each AUDIX system.

T/R

H600-331

GROUP 2

AUDIX

MODEM

RS-232

T/R

H600-331

GROUP 2

AUDIX

MODEM

RS-232

Figure 3-2. Switched RS-232 Network for a Single Switch

Switch (or Customer) Requirements For Switched RS-232 Using

Modems

Each switched RS-232 channel requires one of the following Hayes??-compatible modems:

???AT&T 2296A

???AT&T Paradyne 3820

???AT&T Paradyne DM424

???MICROCOM QX 3296/C (not orderable through AT&T)

_______________________________________________________________________________________

_______________________________________________________________________________________

NOTE

Equivalent modems such as the AT&T Paradyne DL424 instead of the DM424 modem could be used.

The modem requires a connection through one of the switch???s analog ports or can connect directly to a CO line. Switch analog port circuit packs are:

???System 75, Generic 1, and Generic 3: TN742 or TN746B analog line circuit

???System 85 and Generic 2 traditional module: SN222, SN228, or SN228B analog line circuit

???System 85 and Generic 2 universal module: TN742 or TN746B analog line circuit

ALL CONNECTIONS

H600-331

GROUP 2

SWITCH

TO ANALOG PORTS

RS-232

H600-330

GROUP 1

T/R

H600-331

GROUP 2

AUDIX

MODEM

RS-232

T/R

Figure 3-3. Switched RS-232 Network for Separate Locations

If the modems must be located greater than 5.0 feet (1.524 meters) from the AUDIX system, an M25A RS- 232 extender cable is required for each. The modem must be within 50 feet (15.24 meters) of the AUDIX system. The tip/ring circuit should be engineered by a switch representative.

3-6 Switched EIA RS-232 Networks

________________________________________________________________________________________________

________________________________________________________________________________________________

Data Rates for Switched RS-232 Using Modems

When connected through the switch, data rates are limited to speeds up to and including 19.2 Kbps. The speeds may be reduced by the limit of the modems and the public/private facilities involved.

Figure 3-4. Switched RS-232 Network for Separate Locations and a PC

_______________________________________________________________________________________

_______________________________________________________________________________________

SWITCHED RS-232 USING DATA MODULES FOR DCP

By using a data module instead of a modem, the RS-232 channel becomes a DCP channel, at least as far as the switch and the switch network is concerned. RS-232 channels can be converted to DCP mode 1, DCP mode 2, or DCP mode 3. See Figure 3-5, Converting RS-232 Channels to DCP.

???To convert to DCP mode 1 (56 Kbps) or DCP mode 3 (64 Kbps), use a Modular Processor Data Module, Model M1* (MPDM/M1*). In either of these cases, the channels can only be used for incoming calls; they cannot be used for outgoing calls. All outgoing calls must use the DCP ports.

???To convert to DCP mode 2, use a 7400A or 7400B Data Service Unit (DSU). In this case, the channels can be used for incoming or outgoing calls.

Converting RS-232 channels to DCP is particularly useful for System 75, Generic 1, Generic 3, and MERLIN II where a DCP network is desired. Adding the two converted channels to the regular two DCP channels creates a total of four DCP channels. (If the customer desires, these channels can be left as RS- 232 channels giving two RS-232 and two DCP channels, again for a total of four channels. See Chapter 7,

Mixtures of RS-232 and DCP Networks, for examples.)

Sys 75,

G1, or

G3

Public/Private

Interlocation

Facilities

NOTE: The 7400A and 7400B data modules are bi-directional;

the MPDM/M1* is for incoming calls only.

Figure 3-5. Converting RS-232 Channels to DCP

3-8 Switched EIA RS-232 Networks

________________________________________________________________________________________________

________________________________________________________________________________________________

AUDIX System Requirements for Switched RS-232 Using Data Modules For DCP

Each AUDIX system must be running R1V5 or later software and must be equipped with a TN539 or TN539B ACCE circuit pack and the AUDIX Networking Breakout cable (H600-331 Group 1 or 2).

Switch (or Customer) Requirements for Switched RS-232 Using Data Modules for DCP

Each AUDIX RS-232 channel to be converted to DCP requires a data module. The data module must be connected to a DCP port at the switch and should be located within 5 feet (1.524 meters) of the AUDIX system, so an M25A RS-232 extender cable is not needed. The distance from the data module to the switch should be no more than 5000 feet (1524 meters). The following is required:

???One of the following data modules:

???For DCP mode 1 (56 Kbps, synchronous) or DCP mode 3 (64 Kbps, synchronous) use an MPDM/M1*. The MPDM/M1* operates in synchronous mode. An older MPDM can be upgraded to support 56 Kbps with D-kit D-181509. Install the D-kit by following the instructions included with the kit. These channels can only be used for incoming calls.

???For DCP mode 2, use a 7400A or 7400B DSU. The 7400A and 7400B operate in only asynchronous mode. These channels can be used for incoming or outgoing calls.

???One D8W-87 modular cord (provided with the data module) is required for each module.

???Switch DCP interface:

???System 75, Generic 1, and Generic 3: TN754 Digital Line Circuit

???System 85 and Generic 2 traditional module: SN270B General Purpose Port

???System 85 and Generic 2 universal module: TN754

If the converted channels are to be used for DCP Mode 2 operation, two modem pool pairs are also required. See Chapter 5, DCP Mode 2 Networks ??? Modem Pooling. Access to two additional channels on the interlocation facilities might also be required.

Data Rates for Switched RS-232 Using Data Modules For DCP

Data rates are limited to the capabilities of the data modules. MPDM/M1* data modules operate at 56 or 64 Kbps (synchronous), but they do not support dialing out at these speeds, so the converted channels would be limited to receiving calls only. In some cases this limitation would not create a problem. In cases where it would, the 7400A data module, which supports incoming and outgoing calls, can be used. However, with the 7400A, communication is performed at low speeds (up to and including 19.2 Kbps, asynchronous).

4. DCP Mode 1 Networks ??? 56 Kbps

_______________________________________________________________________________________

_______________________________________________________________________________________

AUDIX networks can be implemented using AT&T???s Digital Communications Protocol (DCP) Mode 1. This type of network is only used when the AUDIX systems to be networked are not colocated and, therefore, they require some type of interlocation facility to pass data. (For local networking, see Chapter 6, DCP Mode 3 Networks ??? 64 Kbps.) This chapter presents supported 56 Kbps con???gurations; all other 56 Kbps con???gurations must be designed by Custom Development.

The examples show an AUDIX system using DCP at both ends. See Chapter 7, Mixtures of RS-232 and DCP Networks, for RS-232/DCP combinations. Each of the examples presented in this chapter is accompanied by the equipment required for the AUDIX systems and for the switches that the AUDIX systems serve.

NOTE

Customers who implemented 56 Kbps networking using TN539 ACCE boards may wish to upgrade to AUDIX R1V7 software and a TN539B ACCE in order to take advantage of the performance improvements and built-in loop-around testing capabilities.

CONSIDERATIONS

If a customer is considering using DCP Mode 1 connections in their AUDIX network, keep the following in mind:

???Only remote networking con???gurations are supported.

???Two or more AUDIX systems can be networked via this method.

???AUDIX software must be R1V5 or later. However, R1V7 software is recommended because of the networking feature enhancements and 56 Kbps loopback testing capabilities included in that load when a TN539B ACCE board is used.

???AUDIX systems running R1V5 or R1V6 software require an MPDM/M1* for loopback testing. AUDIX R1V7 systems only require an MPDM/M1* if the two RS-232 ports are to be converted for 56 Kbps use.

???The customer needs a TN539 or TN539B ACCE networking board; the TN539B is recommended because of the 56 Kbps loopback testing capabilities included in that load when AUDIX R1V7 software is used.

???Transmission in this type of network is full-duplex, synchronous, at 56 Kbps.

???The customer will need access to 56 Kbps robbed-bit facilities to a static or dynamic serving of???ce (SO).

???The customer will also need a DCP interface on the switch to connect with the AUDIX and a DS1 interface on the switch to connect with the 56 Kbps network.

4-1

4-2 DCP Mode 1 Networks ??? 56 Kbps

________________________________________________________________________________________________

________________________________________________________________________________________________

NOTE

MERLIN II, System 75, and DEFINITY Generic 1 and Generic 3 can only access two of the four DCP channels. This is a limitation regardless of the AUDIX software and networking circuit pack used. See Chapter 3, Switched EIA RS-232 Networks, for information on expanding this limitation to four channels by adding the AUDIX RS-232 channels.

GENERAL INFORMATION

To use DCP Mode 1 as the transmission protocol, the switch must be set up to access a switched network at 56 Kbps via robbed-bit facilities. These special access lines can be either Dataphone Digital Service (DDS) or ACCUNET T1.5, SDN service providing access to either a static or dynamic Serving Of???ce (SO), or compatible services provided by other vendors. Currently the System 75, System 85, DEFINITY Generic 1, Generic 2, or Generic 3 can provide this type of access. However, System 85 (R2V3 or R2V4) does not support dynamic access. Up to six channels on the 56 Kbps service facility may be required at any one time for System 85 and Generic 2 and up to four channels for System 75, Generic 1, and Generic 3.

Figure 4-1, DCP Mode 1 Network Using Switched 56 Service, shows an arrangement where AUDIX networking is accomplished via 56 Kbps services. Figure 4-2, PC Added to A DCP Network, shows a network of R1V5 or later AUDIX systems with RS-232 access. When RS-232 is available, the customer has a choice of connecting a PC for the CDR feature via dedicated or switched RS-232 (dedicated RS-232 is shown in Figure 4-2).

NOTE

If the customer does not subscribe to switched 56 service, check with the DCP Mode 2, DCP Mode 3, and RS-232 network alternatives before setting up a switched 56 Kbps facility.

_______________________________________________________________________________________

_______________________________________________________________________________________

POINT-OF

PRESENCE

SWITCH

SWITCHED 56

SERVICE

POINT-OF

PRESENCE

SWITCH

CROSS-CONNECT

FIELD

SWITCH H600-331, GROUP 2

AUDIX

DCP

RS-232

(NOT EQUIPPED)

CROSS-CONNECT

FIELD

H600-331

GROUP 2

SWITCH

DCP

AUDIX

RS-232

(NOT EQUIPPED)

Figure 4-1. DCP Mode 1 Network Using Switched 56 Service

4-4 DCP Mode 1 Networks ??? 56 Kbps

________________________________________________________________________________________________

________________________________________________________________________________________________

Static Access

Static SDDN (non-ISDN) allows customers currently subscribing to SDN voice applications to transmit data on the same access arrangement by designating a subgroup de???ned for data terminations. Customers using this con???guration must have a trunk subgroup (TSG) dedicated to SDDN 56 Kbps between the customer premises and a central of???ce. They must also have a System 75 R1V3 Issue 2.1 or later, a System 85 R2V3 or R2V4, or a DEFINITY Generic 1, Generic 2, or Generic 3 switch.

The central of???ce must provide one of the following:

???SDN, T1.5, or DDS and Switched Digital Service (SDS), or compatible service offered by another vendor

???A 4ESS supporting 56 Kbps service

A customer with T1.5 access to a central of???ce tariffed for SDN and T1.5 that does not home to a 4ESS with SDS cannot use this option.

Dynamic Access

Dynamic SDDN (non-ISDN) allows customers that currently subscribe to SDN voice applications to transmit data on the same access arrangement by pre???xing a 115 feature code in front of a telephone number. This allows customers to alternately transmit voice and data on one access line; a separate trunk group for 56 Kbps data is not required.

The T1.5 is dedicated to SDN and is therefore not exclusively 56 Kbps. The central of???ce must route to a 4ESS that supports 56 Kbps via digital connectivity. This access may only be offered on circuits without echo cancellation.

The dynamic arrangement is not possible from locations using DDS access. DDS lines must terminate in a central of???ce that has been tariffed for SDN, DDS, and SDS.

System 85 R2V3 and R2V4 do not support dynamic access. System 75 R1V3 and and DEFINITY Generic 1, Generic 2, and Generic 3 do support dynamic access. However, if a customer wants to use a Generic 2 for Switched 56 Kbps networking, contact the BCSDC for help.

NOTE

Dynamic trunk group arrangements cannot be used by modem pooling. If a customer has both 56 Kbps and modem pooling, two trunk groups are required.

_______________________________________________________________________________________

_______________________________________________________________________________________

AUDIX SYSTEM REQUIREMENTS FOR DCP MODE 1

Each AUDIX system requiring access to a switched 56 network must be running R1V5 or later software. Each AUDIX system must also be equipped with a TN539 or TN539B ACCE circuit pack, the AUDIX Networking Breakout cable (H600-331, Group 1 or Group 2). Also, if the RS-232 ports are to be used for DCP Mode 1 transmission, an MPDM/M1* with an RS-232 interface card is required. If loopback testing is to be conducted for an R1V5 or R1V6 AUDIX system, an MPDM/M1* with a V.35 interface card is required. In addition, each AUDIX system must be within 5000 cable feet (1525 meters) of the switch???s DCP interface.

AUDIX

RS-232

ACCESS

Figure 4-2. PC Added to a DCP Network

4-6 DCP Mode 1 Networks ??? 56 Kbps

________________________________________________________________________________________________

________________________________________________________________________________________________

SWITCH (OR CUSTOMER) REQUIREMENTS FOR DCP MODE 1

To implement AUDIX networking over static or dynamic switched 56 Kbps facilities, the customer???s switch must have a DCP interface to connect with the AUDIX system and a DS1 interface to connect with the 56 Kbps switched network.

Whether a customer is using static or dynamic 56 Kbps, the point-of-presence switch needs to be translated to match the switch, (including wink in/wink out). The RNXs are set up by the customer and added to the network by Network Systems.

Contact the Business Communications Systems Design Center (BCSDC) to design ISDN.

NOTE

The following equipment is typical for 56 Kbps facility access:

???Digital Line Circuits for the AUDIX network

???DS1 Interface

???For R1V5 or R1V6, a Modular Processor Data Module, Model M1* (MPDM/M1*) ACCUNET data module with V.35 interface card (for loopback testing)

NOTE

See the DEFINITY?? Communications System & System 75/85 DS1/DMI/ISDN-PRI Reference (555-025-101) for a complete speci???cation of requirements.

Static Access Switch Requirements

The requirements for networking AUDIX systems via static 56 Kbps facilities depend on the customer???s premise switch:

???System 75

???The switch must be R1V3 2.1 or later.

???All tone detectors must be TN748C (V4 or later).

???DEFINITY Generic 1 and Generic 3

???Any release will support static 56 Kbps access.

???All tone detectors must be TN748C (V4 or later).

_______________________________________________________________________________________

_______________________________________________________________________________________

???System 85

???The switch must be R2V3 or R2V4

???All tone detectors must be at least an SN255.

???DEFINITY Generic 2

???Any release will support static 56 Kbps access.

???For universal modules, the detector must be a TN748C (V4 or later). For traditional modules, the detector is a SN255.

Dynamic Access Switch Requirements

The requirements for networking AUDIX systems via dynamic 56 Kbps facilities depend on the customer premise switch:

???System 75

???The switch must be R1V3 2.1 or later.

???All tone detectors must be TN748C (V4 or later).

???DEFINITY Generic 1 and Generic 3

???Any release will support dynamic 56 Kbps access.

???All tone detectors must be TN748C (V4 or later).

???System 85

???Does not support dynamic access.

???DEFINITY Generic 2

???Any release will support dynamic 56 Kbps access.

???For universal modules, the detector must be a TN748C (V4 or later). For traditional modules, the detector is a SN255.

For help in designing dynamic switched 56 Kbps networking with a Generic 2, contact the BCSDC.

NOTE

The MERLIN II does not support this arrangement. If your customer has a non-DCP switch and wishes to use DCP Mode 1, a DEFINITY Generic 1, Generic 2, or Generic 3 can be used instead of the MERLIN II.

DATA RATES FOR DCP MODE 1

All of the con???gurations shown in this chapter operate at 56 Kbps.

4-8 DCP Mode 1 Networks ??? 56 Kbps

________________________________________________________________________________________________

________________________________________________________________________________________________

5. DCP Mode 2 Networks ??? Modem Pooling

_______________________________________________________________________________________

_______________________________________________________________________________________

AUDIX networks can be implemented using AT&T???s Digital Communications Protocol (DCP) Mode 2. This type of network is only used when the AUDIX systems to be networked are not colocated and, therefore, require some type of interlocation facility to pass data. This arrangement makes use of the switch???s modem pool or can be implemented using stand-alone modem pools. This chapter presents supported con???gurations. The examples show the AUDIX system using DCP at both ends. See Chapter 7,

Mixtures of RS-232 and DCP Networks, for RS-232/DCP combinations.

If a customer develops their own method, contact the Business Communications Systems Design Center (BCSDC) to make sure it is feasible. Each of the examples presented here is accompanied by the equipment required for the AUDIX systems and for the switches that the AUDIX systems serve.

CONSIDERATIONS

If a customer is considering using DCP Mode 2 connections in their AUDIX network, keep the following in mind:

???Only remote networking con???gurations are supported.

???Two or more AUDIX systems can be networked via this method.

???AUDIX software must be R1V3 or later.

???The customer needs a TN366, TN366B, TN539, or TN539B networking board.

???Transmission in this type of network is full-duplex or half-duplex, synchronous or asynchronous, at speeds up to 9600 bps.

???The customer will need rack-mounted or standalone modem pool.

NOTE

System 75 and DEFINITY Generic 1 and Generic 3 can be set up to access only two of the four DCP channels. This is a limitation regardless of the AUDIX software used and the networking circuit pack provided. See Chapter 3, Switched EIA RS-232 Networks, for information on expanding this limitation to four channels.

5-1

5-2 DCP Mode 2 Networks ??? Modem Pooling

________________________________________________________________________________________________

________________________________________________________________________________________________

GENERAL INFORMATION

DCP Mode 2 networking uses the DCP interface between the AUDIX system and the switch. Analog or voice-grade data facilities are used between customer locations. When the switch is a System 85 or DEFINITY Generic 2, the AUDIX system can use up to six ports at any given time. When the switch is a System 75, Generic 1, or Generic 3, up to four ports may be used at any given time.

Figure 5-1, Typical Rack-Mounted Modem Pool Using D-Lead Control, shows a modem pool where a D- Lead is used between the modems and data modules. This arrangement is usually shared by two or more switch applications. The customer can use this arrangement for AUDIX systems so long as the equipment and their option settings are compatible. (Compatible equipment is provided later in this chapter. Compatible option settings are provided in Chapter 11, DCP Mode 2 Installation and Administration.) The customer could also use what is called stand-alone modem pooling. See Figure 5-2, Typical Stand-Alone Modem Pool (No D-Lead Control).

105A MOUNTING

WITH 8 MODEMS

77A MOUNTING

WITH 8 DATA SETS

105A MOUNTING

WITH 8 MODEMS

77A MOUNTING

WITH 8 DATA SETS

NOTE: Use 46A2 mounting if MTDMs are used instead of 7400As.

Figure 5-1. Typical Rack-Mounted Modem Pool Using D-Lead Control

_______________________________________________________________________________________

_______________________________________________________________________________________

TO THE CROSS-

CONNECT FIELD

Figure 5-2. Typical Stand-Alone Modem Pool (No D-Lead Control)

In Figure 5-2, the modems and data modules are typically the models that are contained in their own housings and placed on shelves or on top of other cabinets. However, they could be the rack-mounted versions where they are cabled as stand-alone modem pools (no D-Lead). Stand-alone modem pools are usually dedicated for a particular application.

Figure 5-3, DCP Mode 2 Network (Modem Pooling), shows a DCP Mode 2 network where the switches are either System 75, System 85, Generic 1, Generic 2, or Generic 3.

5-4 DCP Mode 2 Networks ??? Modem Pooling

Figure 5-3. DCP Mode 2 Network (Modem Pooling)

_______________________________________________________________________________________

_______________________________________________________________________________________

AUDIX SYSTEM REQUIREMENTS FOR DCP MODE 2

Each AUDIX system must be running R1V3 or later software and must be equipped with one of the following:

???TN366 AUDIX Communications Controller (ACC) circuit pack

???TN366B ACC circuit pack

???TN539 ACC Enhanced (ACCE) circuit pack

???TN539B ACCE circuit pack

The AUDIX Networking Breakout cable (H600-331, Group 1 or Group 2) provides access to the DCP channels at the AUDIX system. Also, each AUDIX system must be within 5000 cable feet (1525 meters) of the switch???s DCP interface.

SWITCH (OR CUSTOMER) REQUIREMENTS FOR DCP MODE 2

The switch must have a DCP interface and some type of modem pool to provide access to the analog or voice-grade-data interlocation facilities. For System 75, System 85, DEFINITY Generic 1, Generic 2, or Generic 3, the modem pool may be:

???Rack-mounted with a D-Lead

???Rack-mounted or shelf-mounted as a stand-alone modem pool (no D-Lead)

NOTE

It is strongly recommended that all modems in a modem pool be of the same make and model.

5-6 DCP Mode 2 Networks ??? Modem Pooling

________________________________________________________________________________________________

________________________________________________________________________________________________

Basic Switch Needs

The switch must have the following circuit packs to support modem pooling:

???System 75, Generic 1, Generic 2 (universal module), or Generic 3:

???TN748C Tone Detector (System 75 requires a vintage 1 or vintage 3 board; Generic 1 and Generic 3 require vintage 3) ??? required in all carriers of a System 75, but not all carriers of a Generic 1 or Generic 3. (Do not use the TN748B, TN748D vintage 1, or the TN756.) For System 75, Generic 1, and Generic 3, this board does not require assignment, but for Generic 2, it does (use channels 4 and 8).

NOTE

The TN748D vintage 1 board does not currently work for this application. Also, any existing TN748B tone detectors must be upgraded to TN748Cs.

???TN727 Network Controller (System 75) or TN777 Network Controller (Generic 1 and Generic 3) is required.

???MT 771B Maintenance Test Circuit (Generic 2 universal module; equivalent to the SN261).

???System 85 or Generic 2 (traditional module):

???SN253 Auxiliary Tone Plant (one in each module used)

???SN255B or SN255C Tone Detector

???SN261B or SN261C Analog/Digital Facility Test Circuit

DCP Interface for the AUDIX Network Channels

The following digital lines are required to terminate the AUDIX network channels at the switch:

???System 75, Generic 1, or Generic 3:

Two TN754 Digital Line ports are required for the AUDIX DCP channels. Two more ports are required if the AUDIX RS-232 channels are to be converted to DCP.

???Generic 2 (universal module):

Two TN754 Digital Line ports are required for the AUDIX DCP channels. Two more ports are required if the AUDIX RS-232 channels are to be converted to DCP.

???System 85 or Generic 2 (traditional module):

Two SN270B General Purpose Port (GPP) ports are required for the AUDIX DCP channels. Two more ports are required if the RS-232 channels are to be converted to DCP.

_______________________________________________________________________________________

_______________________________________________________________________________________

DCP Interface for the Digital Side of the Modem Pool

The following digital lines are required to terminate the digital side of a modem pool:

???System 75, Generic 1, or Generic 3:

One TN754 or TN754B Digital Line port is required for each modem pool pair. The ports used for the modem pool must appear on a circuit pack(s) separate from the pack(s) used for the AUDIX channels.

???Generic 2 (universal module):

One TN754 or TN754B Digital Line port is required for each modem pool pair.

???System 85 and Generic 2 (traditional module):

One SN270B General Purpose Port is required for each modem pool pair.

Analog (Tip and Ring) Interface to the Interlocation Facilities

One of the following analog trunk circuits is required for terminating interlocation analog facilities at the switch:

???System 75, Generic 1, Generic 2 (universal module), or Generic 3:

???TN747B Central Of???ce (CO) Trunk (1200 to 9600 bps)

???TN753 Direct Inward Dialing (DID) Trunk (1200 to 9600 bps)

???TN760B Tie Trunk (1200 to 9600 bps)

???System 85 or Generic 2 (traditional module):

???SN230B CO Trunk (1200 to 9600 bps)

???SN232B DID Trunk (1200 to 9600 bps)

???SN233C Tie Trunk (1200 to 9600 bps)

Analog Interface for the Analog Side of the Modem Pool

The following analog lines are required to terminate the analog side of the modem pool:

???System 75, Generic 1, Generic 2 (universal module), or Generic 3:

One TN742 or TN746B Analog Line port is required for each modem pool pair.

???System 85 and Generic 2 (traditional module):

One SN243B Analog Data Port is required for each modem pool pair.

5-8 DCP Mode 2 Networks ??? Modem Pooling

________________________________________________________________________________________________

________________________________________________________________________________________________

Modems and Data Modules

The following modems can be used in a modem pool for AUDIX networking. One modem is required for each modem pool pair.

???AT&T 2296A (rack-mounted or stand-alone modem pool). If used in a stand-alone modem pool, an auto-dialer module is required.

NOTE

The 2296A must have a 140C1, (V1.1 or V1.2; supported but no longer purchasable) or a 140F1 Memory Module (V1.1) installed in the right-hand slot at the bottom of the 2296A (modem standing on end). The version can be seen on the front label of the module. It should be labeled ABTLG or ABTTA. If not, order a new chip by calling 1-800-222- PART (comcode 105304935).

???MICROCOM QX 3296/C (stand-alone modem pool).

???AT&T Paradyne 3820 (stand-alone modem pool).

???AT&T Paradyne DM424 (stand-alone modem pool).

NOTE

Equivalent modems such as the AT&T Paradyne DL424 instead of the DM424 modem could be used.

The following data modules can be used in a modem pool used by AUDIX systems. One data module is required for each modem pool pair.

??? 7400A Data Service Unit (rack-mounted or stand-alone modem pool)

NOTE

The 7400A DSU is con???gured for Data Terminal Equipment (DTE) modem pool operation with D-lead controlled 2296-type modems. The mounting package includes an adapter harness (WP90780L0), an OR-6316 bridging adaptor, and a 2296A modem control cable (D-Lead).

??? MTDM (rack-mounted modem pool)

NOTE

Make certain the MTDM is set up in one of two ways: 1) processor PID ABCED and EPROM PID ABGHB are used, or 2) processor PID ABGHC, no EPROM installed, and IC3 is numbered 8052. In either case, make sure that TRIC 4 chips are used (coded 229EJ). If the MTDM requires an upgrade, order the MTDM D-kit (comcode 103033211). This should be D-kit D181470. Old versions of the MTDM (TDM/2 Z700C models) should also get D181469. See Chapter 11, DCP Mode 2 Installation and Administration, for the location and identi???cation of these chips.

In selecting modems or data modules for modem pooling, it is important to note that once a speci???c model is chosen for use on one end of the remote network, only certain models will work on the other end of the remote connection. Combinations that have been tested are listed in the following tables. Combinations that work are marked as ??????OK,?????? and those that do not work are marked ??????FAIL.??????

_______________________________________________________________________________________

_______________________________________________________________________________________

NOTE 1 ??? ???ow control problem. Both the MTDM and the 7400A expect XON/XOFF ???ow control when running 19.2 Kbps.

NOTE 2 ??? works but not cost effective (RS232 modems should be running 19200 also).

NOTE 3 ??? not tested and not cost effective (modems should be running 19.2). Voice messages can emulate XON/XOFF. This results in lost data and dropped connections.

NOTE 4 ??? not tested because not cost effective (424 not off the shelf compatible with 7400A in a rack mount).

NOTE 5 ??? not recommended since MTDM is being manufacture discontinued.

5-10 DCP Mode 2 Networks ??? Modem Pooling

________________________________________________________________________________________________

________________________________________________________________________________________________

NOTE 1 ??? MTDM is being manufacture discontinued.

NOTE 2 ??? ???ow control problem. Both the MTDM and the 7400A expect XON/XOFF ???ow control when running 19.2 Kbps. Voice messages can emulate XON/XOFF. This results in lost data and dropped connections.

NOTE 3 ??? not tested.

NOTE 4 ??? not tested; expected to fail.

NOTE 5 ??? not tested; expected to work.

NOTE 6 ??? 7400A expects a result code that is not given by the modem. 3296 sends a 32 and the 7400A expects a 12. 3296 sends a 37; 424 sends a 17 for 19200 and the 7400A expects a 14.

_______________________________________________________________________________________

_______________________________________________________________________________________

Rack-Mount Equipment

The following equipment is required when rack-mounted modem pools are used (i.e., a D-Lead modem pool):

???72-inch Data or Auxiliary Cabinet and power supply

???The 2296A requires a 105A mounting

???One of the following multi-mounts for the data sets:

???The MTDM requires a 46A2 mounting

???The 7400A requires a 77A mounting

Cabling

Cabling for multi-mount arrangements is provided with the cabinet and the mountings. One D-Lead cable (RS-232C to 25-pair cable), one 25-pair cable for each mounting, and one M25 RS-232C cable for each modem pool pair is required.

Cabling for stand-alone modem pools consists of a 104A adapter, an M25 RS-232C cable (male-male), a D8W-87 modular cord, and building wire for each pair.

DATA RATES FOR DCP MODE 2

This arrangement operates at speeds up to and including 9.6 Kbps (the limit for modem pooling).

DCP MODE 2 FOR A 5ESS SWITCH

The System 75, System 85, DEFINITY Generic 1, Generic 2, Generic 3, and DIMENSION PBX systems support the DCP interface. If the customer has an AUDIX system serving another switch and would like to network the AUDIX system with another location, they could use an AT&T digital PBX for its DCP and modem pooling capabilities. A picture of the DCP Mode 2 arrangement is shown along with a DCP Mode 3 arrangement in Chapter 6, DCP Mode 3 Networks ??? 64 Kbps.

5-12 DCP Mode 2 Networks ??? Modem Pooling

________________________________________________________________________________________________

________________________________________________________________________________________________

6. DCP Mode 3 Networks ??? 64 Kbps

_______________________________________________________________________________________

_______________________________________________________________________________________

AUDIX networks can be implemented using AT&T???s Digital Communications Protocol (DCP) Mode 3. This arrangement can be used when the AUDIX systems are colocated (serving the same switch) or when they are at separate customer sites. This chapter presents supported local and remote networking con???gurations. The examples show the AUDIX system using DCP at both ends. See Chapter 7, Mixtures of RS-232 and DCP Networks, for RS-232/DCP combinations.

If your customer develops their own method, contact the Business Communications Systems Design Center (BCSDC) to make certain it is feasible. Each of the examples presented here is accompanied by the equipment required for the AUDIX systems and for the switches that the AUDIX systems serve.

CONSIDERATIONS

If a customer is considering using DCP Mode 3 connections in their AUDIX network, keep the following in mind:

???Local or remote networking con???gurations are supported.

???Two or more AUDIX systems can be networked via this method.

???AUDIX software must be R1V3 or later. For remote con???gurations, R1V7 software is recommended because of the 64 Kbps loopback testing capabilities included in that load.

???The customer needs a TN366, TN366B, TN539, or TN539B networking board. For remote con???gurations, the TN539B is recommended because of the 64 Kbps loopback testing capabilities included in that board.

???Transmission in this type of network is full-duplex, synchronous, at 64 Kbps.

???For remote con???gurations, the customer will need access to 64 Kbps public or private telephone network facilities; these should normally be a T1 carrier with DS1 services.

NOTE

System 75, DEFINITY Generic 1 and Generic 3, and MERLIN II can be set up to access only two of the four DCP channels. This is a limitation regardless of the AUDIX software used and the networking circuit pack provided. See Chapter 3, Switched EIA RS-232 Networks, on information for expanding this limitation to four channels.

6-1

6-2 DCP Mode 3 Networks ??? 64 Kbps

________________________________________________________________________________________________

________________________________________________________________________________________________

GENERAL INFORMATION

DCP Mode 3 networks use the DCP interface on the AUDIX system and on the switch. Since the AUDIX connections are switched, the AUDIX channels can be shared with the CDR application. For colocated AUDIX systems, communication between AUDIX systems is directly from one switch DCP port to another. Figure 6-1, DCP Mode 3 Network for A Single Switch, shows how this is done with a System 75, System 85, Generic 1, Generic 2, or Generic 3. Figure 6-2, DCP Mode 3 Network for A Non-DCP Switch, shows how the MERLIN II performs this function for a non-DCP switch.

When the AUDIX systems are at different customer locations serving separate switches, interlocation facilities are usually T1 Carrier with a Digital Service 1 (DS1) interface at the switches providing the termination.

AUDIX SYSTEM REQUIREMENTS FOR DCP MODE 3

Each AUDIX system must be running R1V3 or later software and must be equipped with one of the following:

???TN366 AUDIX Communications Controller (ACC) circuit pack

???TN366B ACC circuit pack

???TN539 ACC Enhanced (ACCE) circuit pack

???TN539B ACCE circuit pack

If the AUDIX system is linked to a Generic 2 universal module, the TN366B or TN539 or TN539B must be used if the customer requires all four DCP channels. If a TN366 is used, only channels 1 and 3 can be used. If the AUDIX system is linked to a MERLIN II, the TN366B, TN539, or TN539B must be used.

In addition, for MERLIN II, the following is required:

???MERLIN II control unit (power/processor/base)

???Feature Module II

???Feature Module III

???008D digital station module

???356A adapter (one per AUDIX system), comcode 104158829

???DW8-87 modular cord (two per AUDIX system), comcode 102796950

The AUDIX Networking Breakout cable (H600-331, Group 1 or Group 2) provides access to the DCP channels at the AUDIX system. Also, each AUDIX system must be within 5000 cable feet (1525 meters) of the switch???s DCP interface.

BUILDING WIRE
PATCH CORDS OR

_______________________________________________________________________________________

_______________________________________________________________________________________

CROSS-CONNECT

FIELD

H600-331, GROUP 2

DCP

AUDIX

RS-232

ACCESS

CROSS-CONNECT

FIELD

H600-331

GROUP 2

RS-232

ACCESS

Figure 6-1. DCP Mode 3 Network for a Single Switch

6-4 DCP Mode 3 Networks ??? 64 Kbps

________________________________________________________________________________________________

________________________________________________________________________________________________

Figure 6-2. DCP Mode 3 Network for a Non-DCP Switch

SWITCH (OR CUSTOMER) REQUIREMENTS FOR DCP MODE 3

Switch requirements depend on whether the systems are serving the same switch or are serving different switches.

Colocated Requirements

One of the following switches must be used and equipped with a DCP interface for termination of the AUDIX DCP channels:

???System 75, Generic 1, Generic 2 (universal module), or Generic 3:

Two TN754 Digital Line ports are required per AUDIX system. Although not required, it is recommended that the circuits be on separate packs so all four network channels will not be lost in the event a single pack goes bad.

NOTE

All ports on a TN754 should be assigned as either lines (pdm) or trunks (tdm). Trunk ports will have problems when assigned on circuit packs that have other ringing stations (that is, line circuits). Make sure no ports on the pack is assigned as a trunk (TDM) or assigned to a modem pool.

_______________________________________________________________________________________

_______________________________________________________________________________________

???System 85 or Generic 2 (traditional module):

Two SN270B General Purpose Ports are required per AUDIX system. Although not required, it is recommended that the ports be on separate packs. Then not all four network channels will be lost in the event a single pack goes bad.

???MERLIN II (for colocated systems only)

Two ports on an 008D Digital Line card; the MERLIN II must be equipped as speci???ed earlier in this chapter in AUDIX System Requirements for DCP Mode 3.

When the AUDIX RS-232 channels are converted to DCP, two more ports are required.

Interlocation Requirements

In addition to the requirements listed in the previous paragraphs, a T1 Carrier (DS1 Interface set for Alternate Voice/Data) or the B-channels of an Integrated Systems Digital Network (ISDN) span must be provided for networking between locations.

The BCSDC will design networks using ISDN.

NOTE

The switch must have the following circuit packs:

???System 75, Generic 1, Generic 2 (universal module), or Generic 3:

???TN748C Tone Detector (System 75 requires a vintage 1 or vintage 3 board; Generic 1 and Generic 3 require vintage 3) ??? required in all carriers of a System 75, but not all carriers of a Generic 1 or Generic 3. (Do not use the TN748B, TN748D vintage 1, or the TN756.) For System 75, Generic 1, and Generic 3, this board does not require assignment, but for Generic 2, it does (use channels 4 and 8).

NOTE

The TN748D vintage 1 board does not currently work for this application. Also, any existing TN748B tone detectors must be upgraded to TN748Cs.

???TN727 Network Controller (System 75) or TN777 Network Controller (Generic 1 and Generic 3) is required.

???MT 771B Maintenance Test Circuit (Generic 2 universal module; equivalent to the SN261).

???System 85 or Generic 2 (traditional module):

???SN253 Auxiliary Tone Plant (one in each module used)

???SN255B or SN255C Tone Detector

???SN261B or SN261C Analog/Digital Facility Test Circuit

6-6 DCP Mode 3 Networks ??? 64 Kbps

________________________________________________________________________________________________

________________________________________________________________________________________________

AUDIX systems could use up to six channels at any one time. Figure 6-3, DCP Mode 3 Network for Multiple Locations, shows the DS1 arrangement. For requirements on the switch for DS1, refer to the latest issue of DEFINITY Communications System & System 75/85 DS1/DMI/ISDN-PRI Reference (585-025- 101). If the customer has a non-DCP switch and wishes to use DCP Mode 3 for interlocation communication, see DCP Mode 3 Network For a 5ESS Switch later in this chapter.

DATA RATES FOR DCP MODE 3

This arrangement operates at speeds of 64 Kbps.

Figure 6-3. DCP Mode 3 Network for Multiple Locations

_______________________________________________________________________________________

_______________________________________________________________________________________

DCP MODE 3 FOR A 5ESS SWITCH

Figure 6-4, DCP Mode 3 Network for a 5ESS Switch, shows how a Generic 2 provides the DCP and DS1 interfaces for a 5ESS Centrex switch (an example of a non-DCP switch). The customer has installed the AUDIX system to serve their employees which reside on the Centrex. A ??????bare-bones?????? Generic 2 is installed for its DCP, DS1, modem pooling, and alternate routing capabilities only. No stations reside on the Generic 2. The Generic 2 does the following:

???Provides a 64 Kbps digital network path between the two AUDIX systems shown.

???Provides a 64 Kbps digital network path to an AUDIX system located outside the 5ESS environment.

???Generic 2 software (R2V5) provides the ability to designate the digital path as the ???rst-choice facility with the analog path providing backup (see the Automatic Alternate Routing feature).

NOTE

Any network of this nature is considered experimental and should be developed on an individual basis by the BCSDC.

MODEM

POOL

Figure 6-4. DCP Mode 3 Network for a 5ESS Switch

6-8 DCP Mode 3 Networks ??? 64 Kbps

________________________________________________________________________________________________

________________________________________________________________________________________________

7. Mixtures of RS-232 and DCP Networks

_______________________________________________________________________________________

_______________________________________________________________________________________

This chapter presents supported con???gurations using RS-232 and DCP connections on the same AUDIX system. If your customer develops their own method, contact the Business Communications Systems Design Center (BCSDC) to make certain it is feasible. Look to the previous chapters for the requirements of the following networks.

CONSIDERATIONS

An AUDIX network can be implemented using both RS-232 connections and Digital Communications Protocol (DCP) connections. A single AUDIX system can use both types, or an RS-232 connection can be used at one AUDIX system to talk to another AUDIX system that uses DCP connections.

NOTE

System 75, DEFINITY Generic 1 and Generic 3, and MERLIN II can be set up to access only two of the four DCP channels. This is a limitation regardless of the AUDIX software used and the networking circuit pack provided. See Chapter 3, Switched EIA RS-232 Networks for information on expanding this limitation to four channels.

RS-232 AND DCP AT THE SAME AUDIX SYSTEM

Figure 7-1, RS-232 and DCP at the Same AUDIX, shows how the two AUDIX RS-232 channels and the four AUDIX DCP channels are used on the same AUDIX system. This is particularly useful for a System 75, System 75 XE, Generic 1, Generic 3, or MERLIN II, where only two of the four AUDIX DCP channels can be accessed. In this example, the RS-232 channels are used for communication between the two colocated systems at the top of the ???gure. The DCP channels are used for these systems to communicate with the off-site system at the bottom of the ???gure. In a larger network, where several AUDIX systems to be networked are off-site, it might be advantageous to make the RS-232 channels switched connections as in Figure 7-2, High-Speed Switched RS-232 and DCP AUDIX Connections. This provides a greater degree of access to these systems.

Figure 7-3 shows the DCP channels of the colocated AUDIX systems being used for communication with an off-site AUDIX system. One of the RS-232 channels is used for communication between the colocated systems and the other is used to connect to a PC. The PC could be used to run the Call Detail Recording software package.

7-1

7-2 Mixtures of RS-232 and DCP Networks

________________________________________________________________________________________________

________________________________________________________________________________________________

RS-232 AND DCP AT SEPARATE LOCATIONS

Figure 7-4 shows a case where one of the customer???s AUDIX systems is tied to a DCP switch and the other tied to a non-DCP switch. The system located with the non-DCP switch is brand new, running R1V5 or later software and equipped with a TN539 or TN539B for RS-232 access. The other system is running R1V4 software and equipped with a TN366B (no RS-232 access). Since the DCP switch is equipped with modem pooling, the modem pools are used to convert DCP into analog (t/r) for transmission to the other AUDIX system. If the DCP switch did not have modem pooling, the customer should upgrade to R1V5 or later software.

Figure 7-1. RS-232 and DCP at the Same AUDIX

_______________________________________________________________________________________

_______________________________________________________________________________________

Public/Private

Interlocation

Facilities

NOTE: The 7400A and 7400B data modules are bi-directional;

the MPDM/MI* is for incoming calls only.

Figure 7-2. High-Speed Switched RS-232 and DCP AUDIX Connections

7-4 Mixtures of RS-232 and DCP Networks

Figure 7-3. Using DCP for AUDIX Systems and RS-232 for a PC

Figure 7-4. RS-232 and DCP at Separate Locations

7-6 Mixtures of RS-232 and DCP Networks

________________________________________________________________________________________________

________________________________________________________________________________________________

8. EIA RS-232 Cabling

_______________________________________________________________________________________

_______________________________________________________________________________________

This chapter shows how to cable the AUDIX RS-232 ports to another AUDIX system using direct cabling or by cabling through the switch. These ports can be converted to Digital Communications Protocol (DCP) ports before entering the switch, if desired. This is attractive to System 75, DEFINITY Generic 1, Generic 3, and MERLIN II installations using DCP for interlocation communications since these switches can only access two of the four DCP ports.

DEDICATED RS-232 CABLING

Figure 8-1, Dedicated RS-232 Connection (Within 10 Feet), shows how to cable a dedicated RS-232 AUDIX connection when the AUDIX systems are within 10 cable feet. Figure 8-2, Dedicated RS-232 Connection (Within 50 Feet), shows that an RS-232 extender cable is used when the distance between systems is greater than 10 cable feet apart, but less than 50 feet. Figure 8-3, Dedicated RS-232 Connection (Using Z3A ADUs) shows how to install and wire a dedicated connection that requires data sets to extend the distance capability beyond 50 feet.

Within 50 feet (15.25 meters), the data rate may be up to and including 19.2 Kbps. Within 20 feet (6.1 meters), the data rate may be up to and including 64 Kbps. When data sets are used, check the documentation provided with the data sets for supported data rates.

8-1

Figure 8-1. Dedicated RS-232 Connection (within 10 feet)

Figure 8-2. Dedicated RS-232 Connection (within 50 feet)

8-4 EIA RS-232 Cabling

________________________________________________________________________________________________

________________________________________________________________________________________________

25-PAIR MALE

CONNECTOR

GREATER THAN 50 FT (15.25 M)

Figure 8-3. Dedicated RS-232 Connection (using Z3A ADUs)

SWITCHED RS-232 CABLING

Figure 8-4, Switched RS-232 to an Analog Switch Port, shows how a modem is used to interface the AUDIX system to a DCP or non-DCP switch. Figure 8-5, Switched RS-232 to a DCP Switch Port, shows how a data set is used to interface the AUDIX system to a DCP switch. Option settings for the modems and data modules are given after the ???gures.

Figure 8-4. Switched RS-232 to an Analog Switch Port

Figure 8-5. Switched RS-232 to a DCP Switch Port

8-6 EIA RS-232 Cabling

________________________________________________________________________________________________

________________________________________________________________________________________________

The modems used for switched RS-232 networking may be one of the following modems that can run Microcom Networking Protocol (19.2 MNP) or non-MNP modes. The non-MNP modes will have a ???xed rate of 9600 bps. To con???rm a modem version, connect a 9600 bps terminal to the modem and enter one of the Hayes commands listed below (the result is listed below the command in each case).

???For an AT&T 2296A, enter the following:

???ATI0 RETURN

ID:961

???ATI1 RETURN

version:243

???ATI2 RETURN

checksum:OK

All 2296A modems must have at least a 140C memory module.

???For an AT&T Paradyne 3820, enter the following:

???ATI0 RETURN

ID:144

???ATI1 RETURN

version:212

???ATI2 RETURN

checksum:OK

???For an AT&T Paradyne DM424, enter the following:

???ATI0 RETURN

ID:960

???ATI1 RETURN

version:0626/0403

???ATI2 RETURN

checksum:0454

???For a MICROCOM QX 3296/C, enter the following:

???ATI0 RETURN

ID:960

???ATI1 RETURN

version:010f1

???ATI2 RETURN

checksum:OK

_______________________________________________________________________________________

_______________________________________________________________________________________

DIP Switch Settings

There are no required DIP switch settings for the 7400A or 7400B data sets. The AT&T Paradyne 3820 has no dip switches.

For other modems supported by AT&T, the dip switches should be set as follows:

???For the AT&T Paradyne DM424 (or DL424), the dip switches in the rear of the modem should all be UP.

???For the AT&T 2296A, the dip switches under the front panel should be set so 6 is UP; 1, 5, 7, and 8 are DOWN.

???For the MICROCOM QX 3296/C, set the switches in one of the following ways:

???For MNP 19.2 Kbps mode, set the switches in the front of the modem so 1, 4, 5, 6, 7, and 9 are UP; 2, 3, and 8 are DOWN. Set the switches in the rear of the modem so 4, 5, and 6 are UP; 1, 2, 3, 7, and 8 are DOWN.

???For non-MNP 9600 bps mode, set the switches in the front of the modem so 1, 4, 5, 6, 7, and 9 are UP; 2, 3, and 8 are DOWN. Set the switches in the rear of the modem so 2, 4, and 5 are UP; 1, 3, 6, 7, 8 are DOWN.

Mixing Modem Types and Modes

The AT&T 2296A modem is not in the following table because the other modems are better alternatives. If you do wish to a 2296A, set it up for non-MNP at 9600 bps or for MNP at 19.2 Kbps and try not to mix it with other modem types.

FS ??? modem is in ???xed speed mode. Tested speeds are 19.2K, 9600, and 4800 bps.

MNP ??? tested MNP speeds are 19.2K, 9600, and 4800 bps.

Yes1 ??? all tested cases passed except 3296 (FS @ 4800) to a 424 (FS @ 9600) fails. Calls from the 424 to the 3296 passed.

Yes2 ??? all tested cases passed except 3296 (FS @ 4800) to a 424 (MNP @ 19.2K) fails. Calls from the 424 to the 3296 passed.

8-8 EIA RS-232 Cabling

________________________________________________________________________________________________

________________________________________________________________________________________________

RS-232 to DCP Conversion

This type of connection is shown for a DCP switch in Figure 8-5, Switched RS-232 to a DCP Switch Port.

???To convert an RS-232 channel to DCP mode 2, use a 7400A or 7400B Data Service Unit (DSU). In this case, the channels can be used to originate and receive calls at speeds up to and including 19.2 Kbps.

An initialization string for the 7400A or 7400B will have to be entered on the AUDIX system : translation : network port form.

???If a 7400A is used, make sure it is optioned for Data Communications Equipment (DCE). Lift off the cover and check the vertical card at the front. If it reads DCE, the 7400A is okay. If not, remove the card, turn it around, and reinstall it. If a 7400B is used, it does not require this step. It is always optioned for DCE.

To set up the 7400A, go to the front panel and press the next/no button until the set interface options comes up. Then press the yes button and choose INT=AT COMM.

???For a 7400B, set switch 1 to ON if there is no telephone connected to the data module. To get to switch 1, lift the cover off the modem.

???To convert an RS-232 channel to DCP mode 1 (56 Kbps) or DCP mode 3 (64 Kbps), use a Modular Processor Data Module, Model M1* (MPDM/M1*). In either of these cases, the channels can only be used for incoming calls; they cannot be used for outgoing calls. All outgoing calls must use the DCP ports. Make sure the MPDM/M1* has the option settings shown in the following table.

NOTE

If you are using an older version of the MPDM, it must be upgraded to an MPDM/M1*. Use D-kit D-181509 and follow the instructions included with the kit.

_______________________________________________________________________________________

_______________________________________________________________________________________

Table 8-1. MPDM/M1* Option Settings

SWITCH ADMINISTRATION

The only administration required at the switch is the translation of the new analog or DCP ports for communication with the appropriate endpoints. For analog port translations, see the appropriate switch documentation. For DCP port translations, see Chapter 9, DCP Cabling and Administration.

NOTE

Remember, if you are using MPDM/M1* data modules to convert RS-232 ports to DCP mode 1 or DCP mode 3, these ports can only be used for incoming calls. Consequently, these data modules must be administered as the ???rst members of an incoming hunt group on the switch and the DCP ports should be administered as the remaining members of the hunt group.

8-10 EIA RS-232 Cabling

________________________________________________________________________________________________

________________________________________________________________________________________________

9. DCP Cabling and Administration

_______________________________________________________________________________________

_______________________________________________________________________________________

This chapter provides explanations and illustrations for the cabling, translation, and use of the AUDIX networking channels for supported host switches. If you are setting up a connection requiring interlocation facilities, use this chapter to set up the Digital Communications Protocol (DCP) channels from the AUDIX system to the switch, then go to Chapter 10, DCP Mode 1 Installation and Administration, Chapter 11,

DCP Mode 2 Installation and Administration, or Chapter 12, DCP Mode 3 Installation and Administration to set up the interlocation facilities.

ACC(E) WIRING TO THE SWITCH

For a System 75, System 85, DEFINITY Generic 1, Generic 2, or Generic 3, the DCP circuits at the switch are normally wired to the cross-connect ???eld using 25-pair cable. If you are connecting the AUDIX system to a MERLIN II, D8W-87 modular cord is always used (that is, the cross-connect ???eld is not required).

NOTE

MERLIN II is supported for local networking only. Remote networking/modem pooling with MERLIN II is not supported.

System 75, System 85, and DEFINITY Communications Systems

For the System 75, System 85, and DEFINITY Generic 1, Generic 2, or Generic 3, the AUDIX DCP ports must be wired to the switch through the cross-connect ???eld. Figure 9-1, DCP Cabling to the Switch Using the H600-331, Group 2 Cable, shows how this is done.

9-1

9-2 DCP Cabling and Administration

Figure 9-1. DCP Cabling to the Switch Using the H600-331, Group 2 Cable

Non-DCP Switch Applications

The AUDIX DCP channels are connected directly to the MERLIN II using D8W-87 modular cords. The installation of the MERLIN II Communications System is the responsibility of the customer or AT&T General Business Systems. Thus, the following procedure requires a coordinated effort between them and the AUDIX system installer. Make sure that the TN366B, TN539, or TN539B board is installed in the AUDIX system and that the AUDIX system and MERLIN II are operational.

1.Assemble the system modules as shown in Figure 9-2, MERLIN II Default Con???guration and Slot Assignments, and power-on the MERLIN II system. The numbering of the jack positions will be the default numbering shown on the 008D modules in Figure 9-2. If additional 008D modules need to be added for additional ports, the numbering scheme continues to increase upward from bottom to top, left to right as shown.

_______________________________________________________________________________________

_______________________________________________________________________________________

Figure 9-2. MERLIN II Default Con???guration and Slot Assignments

2.At the rear of the AUDIX cabinet is a 25-pair female connector labeled ACC or ACCE. Connect the 25-pair male connector of the H600-331, Group 1 cable to this ACC connector. Or connect the 25- pair male connector of a 356A adapter to this connector. Either setup will provide you with the two D8W-87 female modular connectors required. The H600-331, Group 1 modular connectors should have 451A adapters on the ends. Figure 9-3, AUDIX to MERLIN II Connectivity, shows a 356A adapter being used.

3.Plug one end of a DW8-87 cord (male-male) into Jack No. 1 of the 356A adapter or Connector 1 of the H600-331, Group 1 cable. If the AUDIX system is within 5 feet of the MERLIN II, the 451A adapter can be removed from Connector 1, and Connector 1 (an D8W-87 male connector) can be used in the next step.

Repeat this step with the second D8W-87 cord. Use Jack No. 2 of the 356A adapter or Connector 2 of the H600-331, Group 1 cable.

9-4 DCP Cabling and Administration

Figure 9-3. AUDIX to MERLIN II Connectivity

4.Run the other ends of the D8W-87 cords to the MERLIN II (008D module). Plug them in to the desired positions.

Any digital module (008D) jack position will work. The jack position determines the number assigned to the AUDIX DCP data port.

5.Repeat steps 1 through 4 for each AUDIX-to-MERLIN II connection.

_______________________________________________________________________________________

_______________________________________________________________________________________

SWITCH ADMINISTRATION

The BCSDC will design hunt groups for AUDIX networking so the customer does not need to do so. Always use the extension numbers and hunt sequences provided by the BCSDC for AUDIX networking administration.

The AUDIX networking port administration covered in this section is used in all AUDIX networking setups. The following switch administration is required:

???At the System 75, Generic 1, and Generic 3, you will be assigning two channels. These switches use only I-channel 1 of each DCP circuit. At the AUDIX system, they appear as Channels 1 and 3. Channels 2 and 4 are not currently used.

???System 85 and Generic 2 use both I-channels of each circuit, so you will be assigning four channels. At the AUDIX system, they appear as Channels 1 through 4.

???The MERLIN II does not require administration for AUDIX DCP channels. The jacks used on the 008D module have ???xed dialing codes. At the AUDIX system, the MERLIN II connections appear only as Channels 2 and 4 (only I-channel 2 is used with each DCP circuit). Channels 1 and 3 are not used.

NOTE

If the RS-232 AUDIX channels are converted to DCP (see Chapter 3, Switched EIA RS-232 Networks), you will need to assign two more channels. These appear at the AUDIX system as channels 5 and 6.

If you are using MPDM/M1* data modules to convert RS-232 ports to DCP mode 1 or DCP mode 3, these ports can only be used for incoming calls. Consequently, these data modules must be administered as the ???rst members of a hunt group on the switch and the DCP ports should be administered as the remaining members of the hunt group.

System 75, Generic 1, and Generic 3 Administration

Use the following procedure to assign the AUDIX DCP channels (terminated at two DCP circuits).

1.Use ??????add data-module xxxxx?????? to assign a DCP port where xxxxx is a 1- to 5-digit unused extension.

2.Set Type to pdm.

3.Set Port to the location of the TN754 circuit that is wired to the AUDIX DCP port (cable H600-331, Group 1; connector 1, 2, A, or B).

4.Press ENTER .

5.Repeat steps 1 through 4 for each DCP port used.

6.Use ??????add hunt-group next?????? to assign a hunt group.

9-6 DCP Cabling and Administration

________________________________________________________________________________________________

________________________________________________________________________________________________

Use the hunt groups the BCSDC has designed for AUDIX networking.

NOTE

7.Set Group Extension to another unused extension. Use a DID extension if the AUDIX system is to be accessed from a remote AUDIX system.

8.Set Group Type to ucd.

9.Set Message Center to none.

10.Set ACD to n.

11.Press ENTER .

12.Go to Page 2 and assign the DCP extensions to this hunt group. If you are converting the AUDIX RS-232 ports to DCP, you will have four networking extensions.

NOTE

Assign extensions in the order determined by the BCSDC. For example, the hunt sequence may start with port 5.

System 85 Administration

System 85 can use both I-channels of the DCP port. This provides access to all four AUDIX DCP networking ports. The DCP circuits are assigned as follows using the Maintenance and Administration Panel (MAAP).

1.Assign a class of service (cos) for the AUDIX networking ports that has touch-tone dialing and data protection ??? permanent enabled (use Proc 010, Word 1 and Proc 010, Word 3).

* Fields 2 through 10 may be assigned for toll fraud protection.

$ For remote networking con???gurations, if the AUDIX networking extension is dialing AAR or ARS to reach a remote AUDIX system, make sure an appropriate FRL is assigned to the AUDIX networking extensions??? cos (Proc 010, Word 3, Field 23).

_______________________________________________________________________________________

_______________________________________________________________________________________

2.The bearer capability of the AUDIX networking ports should be assigned to their class of service using Proc 010, Word 4.

* Value of this ???eld differs depending on networking con???guration.

3.Assign an extension number for each networking port, four extension numbers for the DCP-only ports or six if you are converting the RS-232 ports to DCP (use Proc 000, Word 1). Either port 1 (if you are using only the DCP ports) or port 5 (if you are converting the RS-232 ports) should have a DID extension if the AUDIX system is to be accessed from a remote AUDIX system through the public network.

The extension numbers shown are only examples; use the extensions from the BCSDC.

4.Assign the extensions to hunt to each other (use Proc 000, Word 2). You will administer hunting for four extensions if only the DCP ports are used, or six extensions if the RS-232 ports have been converted to DCP. Normally the extensions hunt in a circular pattern unless directed otherwise by the BCSDC. Hunt sequences are determined by the BCSDC.

This sequence is only an example; use the hunt sequence from the BCSDC.

5.For each GPP equipment location, assign the following characteristics (use Proc 051, Word 1). Unless speci???ed, leave the ???eld dashed or blank.

a.Terminal Type ??? select one of the following:

???For DCP ports, administer terminal type as AP32 (Field 6 = 10)

???If converting RS-232 ports to DCP, administer terminal type as PDM (Field 6 = 4)

b.Originating Preference = Prime Appearance (Field 10 = 2)

c.Terminating Preference = None (Field 11 = 0)

d.Keyboard Dialing = active (Field 13 = 1)

_______________________________________________________________________________________

9-8 DCP Cabling and Administration

________________________________________________________________________________________________

________________________________________________________________________________________________

*This ???eld may be 10 for DCP ports or 4 for converted RS-232 ports.

6.For each GPP equipment location, assign two appearances with the following characteristics (Proc 052, Word 1):

a.Device Type = Basic Set (Field 6 = 0)

b.Member = 0 (???rst appearance), then 1 (second appearance) (Field 7 = 0 or 1)

c.Extension Number = extensions assigned above (Field 8)

d.Call Appearance Number on this Set = 1 (Field 9 = 1)

e.Line Type = Prime Line (Field 10 = 1)

f.Alert Type = alert (Field 11 = 1)

g.Home Terminal = home terminal (Field 12 = 1)

h.Originating Call Appearance Only = not originating only (Field 13 = 0)

i.SAC Group = not a SAC member (Field 14 = 0 on R2V4 or later systems)

7.Auxiliary tone pack: A System 85 must have at least one SN253C auxiliary tone pack in every module; this pack is administered using Proc 252, Word 2.

8.Tone detector pack (remote networking con???gurations): A System 85 requires an SN255 tone detector pack or an SN255B pack in applications requiring modems that use 2100 Hz answer tone (such as the AT&T 2296, 2248, or 2224). Four tone detectors should be assigned on each SN255 board; the tone-detector trunk group is assigned in Proc 100, Word 1 as trunk type 100, and circuits are assigned to this trunk group in Proc 150.

_______________________________________________________________________________________

_______________________________________________________________________________________

Generic 2 Administration

Generic 2 can use both I-channels of the DCP port. This provides access to all four AUDIX DCP networking ports. The DCP circuits are assigned as Dual Port Data. This section describes how to administer AUDIX networking on a Generic 2 switch using the enhanced mode of Manager II.

Some general notes on Generic 2 requirements include:

???Auxiliary tone pack: A Generic 2 with traditional modules must have at least one SN253C auxiliary tone pack in every traditional module; this pack is administered using Proc 252, Word 2. No administration is required for the TN748C tone pack in a Generic 2 universal module.

???Tone detector pack (remote networking con???gurations): A Generic 2 with traditional modules requires an SN255 tone detector pack, or an SN255B pack in applications requiring modems that use 2100 Hz answer tone (such as the AT&T 2296, 2248, or 2224). Four tone detectors should be assigned on each SN255 board; the tone-detector trunk group is assigned in Proc 100, Word 1 as trunk type 100, and circuits are assigned to this trunk group in Proc 150.

The TN748C board in a Generic 2 universal module can use channels 4 and 8 for tone detection; up to two tone-detector circuits can be assigned on each board and placed in a tone-detector trunk group. The number of tone detector circuits needed depends on the data traf???c characteristics of the switch.

???Universal modules: If the switch is a Generic 2 with universal modules, make sure the AUDIX system has a TN366B, TN539, or TN539B ACC(E) board. Otherwise, you can only assign two of the four available DCP channels.

Manager III and Manager IV Administration

DEFINITY Manager III and Manager IV are covered in their own documentation sets. Refer to the appropriate manual for more information on administering systems using Manager III or Manager IV:

???DEFINITY?? Manager III Operations (585-222-701)

???DEFINITY?? Manager IV Facilities Management Operations (585-223-702)

???DEFINITY?? Manager IV Terminal Change Management Operations (585-223-701)

???DEFINITY?? Manager IV System Administration (585-223-700)

9-10 DCP Cabling and Administration

________________________________________________________________________________________________

________________________________________________________________________________________________

Manager II Administration

Manager II assignments for Generic 2 are as follows:

1.Assign all four extension numbers (or six if you are converting RS-232 ports to DCP) to the system (Proc 000, Word 1) as shown in Figure 9-4, Manager II Administration of a DCP Port (Proc 000, Word 1). The extension number shown is only an example; use the extension numbers provided by the BCSDC.

Use a class-of-service (Proc 010, Word 1 and Word 3) that has touch-tone dialing capability and data protection ??? permanent. Class of service 10 is only an example.

ENHANCED MODE - PROCEDURE: 000, WORD: 1

SINGLE TERMINAL TRANSLATION

1.Extension or VDN: 32330

TERMINAL EQUIPMENT LOCATION

2.Module: --

3.Cabinet: -

4.Carrier: -

5.Slot: --

6.Circuit: --

7.Class of Service: 10

8.Port Type: - Extension administered in Procedure 052 Word 1

9.Disable Signaling: - Non-DS1 lines

DISPLAY ONLY

10.Recent Disconnect: 0 Extension is not in recent disconnect

11.Use the Procedure(s) Shown: 052

Figure 9-4. Manager II Administration of DCP Port (Proc 000, Word 1)

_______________________________________________________________________________________

_______________________________________________________________________________________

2.Assign all four extensions (or six if you are converting RS-232 ports to DCP) to Bearer Capability Class-Of-Service (BCCOS) 6 as shown in Figure 9-5, Manager II Administration of a DCP Port (Proc 000, Word 3). The extension number shown is only an example.

NOTE

The default BCCOS 0 through 8 should not be modi???ed to support AUDIX networking. If a custom BCCOS is required, create a new BCCOS using the default values shown in PROC 014, Words 1 and 2. Refer to the DEFINITY Generic 2 Administration Procedures manual (555-104-506) if needed.

The BCCOS 6 default parameters are also shown in Figure 9-6, Manager II Administration of a DCP Port (Proc 014, Word 1), and Figure 9-7, Manager II Administration of a DCP Port (Proc 014, Word 2).

5.Bearer Capability Class of Service: 6

6.Universal Code Calling ID: ---

Figure 9-5. Manager II Administration of DCP Port (Proc 000, Word 3)

9-12 DCP Cabling and Administration

________________________________________________________________________________________________

________________________________________________________________________________________________

ENHANCED MODE - PROCEDURE: 014, WORD: 1

CALL TYPES AND ACTION TAKEN

4.Voice: 0 Circuit switch the call

5.Voice Grade Data: 1 Insert a mode 2-to-analog modem pool facility

6.Mode 0: 0 Circuit switch the call

7.Mode 1: 0 Circuit switch the call

8.Mode 2: 0 Circuit switch the call

9.Mode 3: 0 Circuit switch the call

10.Unknown Digital: 0 Circuit switch the call

11.Unknown Analog: 1 Insert a mode 2-to-analog modem pool facility

12.Mode 3/2: 0 Circuit switch the call

13.X.25: 0 Circuit switch the call

Figure 9-6. Manager II Administration of DCP Port (Proc 014, Word 1)

3.The DCP extensions default to BCCOS 1. Change this to BCCOS 6 as shown in these examples. This allows the DCP port to communicate with either a digital or analog outside facility.

A call to/from this port will be circuit switched unless it is voice-grade data or unknown analog. In these cases, a modem pool will be inserted.

_______________________________________________________________________________________

_______________________________________________________________________________________

ENHANCED MODE - PROCEDURE: 014, WORD: 2

BEARER CAPABILITY CLASS OF SERVICE - DATA OPTIONS

1. Bearer Capability COS: 6

DATA RATE

2.64000 bps: 1 Supported

3.56000 bps: 1 Supported

4.19200 bps: 1 Supported

5.9600 bps: 1 Supported

6.4800 bps: 1 Supported

7.2400 bps: 1 Supported

8.1200 bps: 1 Supported

9.300 bps: 1 Supported

10.Low Speed: 0 Not supported

11.Synchronous: 1 Synchronous

12.Duplex: 0 Full duplex

13.Clock: 0 Internal

14.Default Data Rate: 9 64000 bps

Figure 9-7. Manager II Administration of DCP Port (Proc 014, Word 2)

9-14 DCP Cabling and Administration

________________________________________________________________________________________________

________________________________________________________________________________________________

4.Assign the DCP equipment location as Dual Port Data (Proc 051, Word 1). Make the entries as shown in Figure 9-8, Manager II Administration for DCP Ports (Proc 051, Word 1). The equipment location shown is only an example.

5.Repeat step 4 for the second DCP equipment location.

7.Option: 0 data only

PHYSICAL TYPE

8.Data: 1

9.Display: _

Figure 9-8. Manager II Administration for DCP Ports (Proc 051, Word 1)

_______________________________________________________________________________________

_______________________________________________________________________________________

6.Assign line appearances to the DCP equipment location. Make the entries as shown in Figure 9-9,

Manager II Administration for DCP Ports (Proc 052, Word 1). The extension shown in Field 8 is only an example.

7.The ???rst extension is assigned to Device Type 0 (Field 6) Member 0 (Field 7). Repeat step 6, only use Device Type 0 Member 1 and assign a different extension to it.

8.Repeat steps 6 and 7 for the second DCP equipment location. Assign two other extension numbers to Device Type 0 (Field 6) Members 0 and 1 (Field 7) for this equipment location.

If desired, you may display the extensions using Proc 052, Word 2.

ENHANCED MODE - PROCEDURE: 052, WORD: 1

10.Line Type: 1 Prime line

11.Ringing Type: 1 Ringing

12.Home Terminal: 1 Yes

13.Originating Only: 0 No

14.SAC Group: 0 No

Figure 9-9. Manager II Administration for DCP Ports (Proc 052, Word 1)

9.After the extensions are assigned here, their BCCOS may be reset to 1. Go back to Procedure 000, Word 3 and check if the BCCOS is still 6. If not, reset it to 6 if necessary. Check each of the AUDIX networking extensions.

9-16 DCP Cabling and Administration

________________________________________________________________________________________________

________________________________________________________________________________________________

10. DCP Mode 1 Installation and Administration

_______________________________________________________________________________________

_______________________________________________________________________________________

In most cases where the customer wishes to use this type of network, it will be because the network connections are already in place. T1 facilities connect the Private Branch Exchange (PBX) to a network point-of-presence switch which in turn is connected to the 56 Kbps facilities. Additional trunk circuits may have to be added to handle the additional traf???c. The Business Communications Systems Design Center (BCSDC) must make this determination.

SWITCH COMPONENT INSTALLATION

See the appropriate switch and/or feature documentation for installing circuit packs and wiring trunks on the switch.

SWITCH ADMINISTRATION

Check to make certain the customer???s switch and the central of???ce switch are compatible. For DCP Mode 1 networking, the trunk group used to transport the AUDIX calls must be DS1 and the DS1 pipe must employ robbed-bit signaling.

4ESS Administration

If not already done, the 4ESS must be translated for 56 Kbps operation as follows:

???The 4ESS facilities must be translated for robbed-bit transmission.

???If the 4ESS is using AMI, the System 75, System 85, or DEFINITY Communications System must be translated for ZCS (not B8ZS).

???The trunk types on the 4ESS and switch must match (for example, both may be translated as wink/wink type trunks).

10-1

10-2 DCP Mode 1 Installation and Administration

________________________________________________________________________________________________

________________________________________________________________________________________________

System 75, Generic 1, and Generic 3 Administration

Administration depends on whether the customer is using static (high-speed data only) or dynamic (voice and high-speed data) switched 56 access.

NOTE

Any Generic 1 switches in a 56 Kbps network that includes a Generic 2 must be running at least Issue 7.2 software.

???Static Access: For static (high-speed data only) 56 Kbps switched access, the switch must be administered as follows:

???Using the add trunk-group form, set the comm type to DATA and administer the switch for wink in/wink out.

???Using the change system-parameters features form, set the off-premise tone detect to 25.

???Using the change ds1 circuit pack form, set the signaling mode ???eld to robbed-bit and set either ZCS or B8ZS to match the CO.

???Dynamic Access: For dynamic (voice and high-speed data) 56 Kbps switched access, the switch must be administered as follows:

???Using the add trunk-group form, set the comm type to RBAVD, the baud rate (or bit rate) to 19.2, and administer the switch so it matches the central of???ce trunk type.

???Using the change system-parameters features form, set the off-premise tone detect to 25.

???Using the change ds1 circuit pack form, set the signaling mode ???eld to robbed-bit and set either ZCS or B8ZS to match the CO.

_______________________________________________________________________________________

_______________________________________________________________________________________

System 85 Administration

The following translations need to be completed for a System 85 for static switched 56 Kbps (dynamic access is not supported for System 85 R2V3 or R2V4; System 85 R2V2 does not support 56 Kbps networking). System 85 is administered as follows using the MAAP.

1.Using Procedure 010, Word 4, assign mode 1 data to the class of service associated with the AUDIX networking ports (Field 3 = 1).

2.Using Procedure 100, Word 1, translate the trunk group (tgroup) as follows:

a.Assign a dial access code (DAC) in Fields 2 through 5. The dial string used by the AUDIX networking ports must be routed via a dedicated (static) trunk group using this DAC.

b.Assign a DMI trunk type (Field 6 = 109). The DS1 facility used to transport the 56 Kbps call must employ robbed-bit signaling.

3.Using Procedure 101, set the following values:

a.Set Touch Tone In and Touch Tone Out to 1 (Fields 6 and 7 = 1).

b.Set the AVD bit for the trunk group to 0 (Field 17 = 0).

10-4 DCP Mode 1 Installation and Administration

________________________________________________________________________________________________

________________________________________________________________________________________________

Generic 2 Administration

The following Manager II translations need to be completed for a Generic 2 for static switched 56 Kbps networking. For Generic 2 translations using dynamic 56 Kbps networking, contact the BCSDC.

NOTE

DEFINITY Manager III and Manager IV are covered in their own documentation sets. Refer to the list of documents in Chapter 9 to ???nd the appropriate manual for administering systems using Manager III or Manager IV.

1.Using Procedure 100, Word 1, make the assignments shown in Fields 1 through 9. The trunk group (76) and the dial access code/trunk ID code shown are only examples; enter the appropriate values supplied by the BCSDC.

To administer members of the trunk group, use Procedure 116.

NOTE

If you need to change the signaling type, use Procedure 100, Word 3.

ENHANCED MODE - PROCEDURE: 100, WORD: 1

TRUNK GROUP TRANSLATION

1. Trunk Group: 76

DIAL ACCESS CODE/TRUNK ID CODE

2.Digit 1: 7

3.Digit 2: 5

4.Digit 3: 1

5.Digit 4: -

6.Trunk Type: 41

7.Dial Access Restriction: 0 Access is allowed using DAC

8.Personal CO Line Appearance: 0 Not used for CO line appearance

9.Public Network Access/Egress: 1 Enabled

Figure 10-1. Manager II Mode 1 Administration (Proc 100, Word 1)

_______________________________________________________________________________________

_______________________________________________________________________________________

2.Using Procedure 100, Word 2, assign BCCOS 7 to the trunk group (trunk group 76 is only an example).

NOTE

BCCOS 7 is the default and should not be modi???ed. However, if BCCOS 7 has been modi???ed at your site, use a custom BCCOS that has the default values of BCCOS 7 (one that uses robbed-bit signaling). Refer to the DEFINITY Generic 2 Administration Procedures manual (555-104-506) for default BCCOS values if needed.

ENHANCED MODE - PROCEDURE: 100, WORD: 2

TRUNK GROUPS - MODEM POOLING AND BCCOS

MODEM POOLING

3.Originate Mode: _

4.Answer Mode: _

5.Modem Type: _

6.First Choice: _

7.Test Type: _

Figure 10-2. Manager II Mode 1 Administration (Proc 100, Word 2)

10-6 DCP Mode 1 Installation and Administration

________________________________________________________________________________________________

________________________________________________________________________________________________

3.Using Procedure 101, Word 1, make the assignments shown below:

ENHANCED MODE - PROCEDURE: 101, WORD: 1

TRUNK GROUP CHARACTERISTICS

1.Trunk Group: 76

2.Balance: 0 Disabled

TIMED RECALL

10.Time: 0

11.Level: 0 Recall occurs when recall time expires

12.CDR Variable Timer: -- Default (procedure 275 Word 3 field 12)

13.Pad Group: 0 Determined by trunk type in Procedure 100 Word 1

14.Tie Toll: 0 Not toll restircted

15.APLT Features Allowed: 0 Disabled (CCSA trunk)

16.Disconnect Supervision: 0 Disabled

Figure 10-3. Manager II Mode 1 Administration (Proc 101, Word 1)

_______________________________________________________________________________________

_______________________________________________________________________________________

LOOPBACK TESTING

AT&T Network Systems requires loopback capabilities in order to test and support AUDIX networking over switched digital services (SDS). With R1V7 software and a TN539B ACCE, this test can be enabled via the maintenance : network form. On R1V5 and R1V6 systems, an MPDM/M1* is required for loopback testing.

Loopback Testing for R1V7

On AUDIX R1V7 systems, you can test the connection between the local AUDIX system and the 56 Kbps serving of???ce (SO), as shown in Figure 10-4, 56 Kbps Network Loop-Around Test. Normally only the four DCP ports are tested, but if you have an MPDM/M1* connected to ports 5 and 6, they may also be tested using the AUDIX maintenance : network form.

While a channel is in loopback mode, it will be unavailable to send information to remote systems or receive information from remote systems. Incoming calls will be answered, but the calling system will be unable to establish a connection; eventually it will drop the call and attempt to call back at its next scheduled transmission time.

Also, if you put a channel in loopback mode, any active calls will be dropped. It is therefore recommended that before you perform this test you check the status of the channel. It is also not a good idea to perform this test during peak traf???c times.

1. Go to the maintenance : network form. Set select test to 7 to test a 56 Kbps network

NOTE

If you have an MPDM/M1* between the AUDIX system and the PBX, you may also test channels 5 or 6 (the RS-232 channels) for 56 Kbps operation.

2.Have the serving of???ce place a call to the telephone number assigned to the channel you speci???ed on the maintenance : network form. If the test is successful, any data the serving of???ce sends over the AUDIX channel will be echoed back.

3.Go to the maintenance : network form. Set select test to 9 to take the channel out of

10-8 DCP Mode 1 Installation and Administration

________________________________________________________________________________________________

________________________________________________________________________________________________

SYSTEM 85

DCP

POINT-

OF-

PRESENCE

SWITCH

. . . . . . . . . . . . . . . . . . . . . . . . .

MAINTENANCE: NETWORK FORM:

NETWORK LOOPAROUND START 56/64 Kbps

Figure 10-4. 56 Kbps Network Loop-Around Test

Loopback Testing for R1V5 and R1V6

For R1V5 and R1V6, loopback capabilities are provided by an MPDM/M1*.

Setting Up the MPDM/M1*

NOTE

The MPDM/M1* used for loopback testing is not the same one used for the RS-232 ports on the AUDIX system.

To install the MPDM/M1*, complete the following steps:

1.If the customer did not order an MPDM/M1*, modify the MPDM to support 56 Kbps by completing the following steps.

_______________________________________________________________________________________

_______________________________________________________________________________________

NOTE

If the faceplate of the MPDM reads ACCUNET, then the D-kit has already been installed and you should not need to modify the MPDM in any way. In this case, skip to step 2.

a.Install the 56 Kbps D-181509 kit by following the instructions included with the kit. The D-kit is used to modify the MPDM so it will work with 56 Kbps facilities.

b.Install the V.35 DTR card in the MPDM. The V.35 card allows a call to be answered without an attached DTE device.

To see if the V.35 card has already been installed, power up the MTDM without having a DTE attached. The Terminal Ready LED on the MPDM will be on if the V.35 DTR interface has previously been installed.

c.Solder two loops or build and connect a male loopback plug to make the connections shown in Figure 10-5, V.35 Male Connector.

V.35 MALE CONNECTOR

P (Tx1)

R (Rx1)

S (Tx2)

T (Rx2)

Figure 10-5. V.35 Male Connector

2.Install the MPDM/M1* by following the instructions that come with the data module.

3.Set all MPDM option switches to OFF (left) except the following:

???Set OFF/56K to 56K

???Set ASYNCH/SYNC to SYNC

???Set EXT/INT to INT

???Set OFF/ANET to ANET

???Set OFF/AANS to AANS

10-10 DCP Mode 1 Installation and Administration

________________________________________________________________________________________________

________________________________________________________________________________________________

Performing Loopback Test

AT&T Network Systems requires loopback capabilities in order to test and support AUDIX networking over switched digital services (SDS).

NOTE

The AUDIX networking ports will be unavailable for the duration of the loopback test. Therefore, the test should not be conducted during prime-time hours.

In order to conduct a loopback test, you must have installed the loopback MPDM/M1*. One MPDM/M1* is required per customer location, not per AUDIX system. (The MPDM/M1* must have the V.35 interface described earlier in this chapter.) You will also need to disconnect the AUDIX Networking Breakout Cable (H600-331, Group 2) from the AUDIX system for the duration of the test, so the system will have no networking capabilities during the test. See Figure 10-6, Loopback Test with the H600-331, Group 2 Cable. (If you are using the H600-331, Group 1 cable, you will only need to use one of the DCP lines. See Figure 10-7, Loopback Test with the H600-331, Group 1 Cable.)

When a loopback test is to be conducted, complete the following steps:

1.Busy out the AUDIX networking ports as follows:

a.If the RS-232 ports are converted to DCP using an MPDM/M1*, set the SELFTEST/NORMAL switch on the MPDM to SELFTEST.

b.Use the maintenance : network form to busy out all of the AUDIX networking ports.

2.Connect the loopback MPDM/M1* (with the V.35 interface card) as follows:

???If you are using the H600-331, Group 2 Cable, do one of the following:

???If a 356A adapter is available (see Figure 10-6, Loopback Test with the H600-331, Group 2 Cable), disconnect the Amphenol 50-pin male connector from the ACC D05 port on the AUDIX system. Connect the Amphenol connector to the 25-pair male connector 356A adapter using a 50-pin female-to-female Amphenol adapter. Plug one end of the D8W-87 cord into slot 1 of the 356A adapter, and the other end into the MPDM/M1* data module. This makes DCP channels 1 and 2 available for the loopback test.

???If a 356A adapter is not available, patch a 103A adapter to the DCP interface for the ???rst physical port (ELL) at the cross-connect ???eld. Plug one end of the D8W-87 cord into the 103A adapter, and the other end into the MPDM/M1* data module. This makes DCP channels 1 and 2 available for the loopback test.

???If you are using the H600-331, Group 1 Cable, borrow one of the AUDIX DCP ports as shown in Figure 10-7, Loopback Test with the H600-331, Group 1 Cable.

3.Put the loopback MPDM/M1* (with the V.35 interface) into normal mode.

4.Have Network Systems conduct the loopback test on the port connected to the loopback MPDM/M1*. Once the MPDM/M1* answers the call, put it into remote loopback mode.

5.When the test is completed, have Network Systems disconnect the call or press the ORIGINATE/DISCONNECT switch on the loopback MPDM.

6.Connect the network breakout cable (H600-331, Group 1 or Group 2) back to the AUDIX system as before the test.

_______________________________________________________________________________________

_______________________________________________________________________________________

7.If the RS-232 ports are converted to DCP using an MPDM/M1*, set the SELFTEST/NORMAL switch on the MPDM back to NORMAL.

8.Use the maintenance : network form to unbusy the AUDIX ports.

Figure 10-6. Loopback Test with the H600-331, Group 2 Cable

10-12 DCP Mode 1 Installation and Administration

Figure 10-7. Loopback Test with the H600-331, Group 1 Cable

11. DCP Mode 2 Installation and Administration

_______________________________________________________________________________________

_______________________________________________________________________________________

This chapter explains how to install and translate stand-alone modem pools and rack-mounted (D-Lead) modem pools. Once the modem pools are installed and translated, any problems should be directed to the Technical Service Center (TSC).

INSTALLING A 2296A AND MTDM IN A MODEM POOL

The following shows how to install and administer 2296A modems and MTDM data modules in their multi-mount con???guration. This arrangement uses a standard 72-inch cabinet with multiple mounts.

Do not apply power to the cabinet or any related equipment until all components are installed and ready for service.

WARNING

Install the Modem Pool Cabinet

The modem pool cabinet requires a 57 to 63 Hz, 105 to 129 VAC circuit. Expect to draw a maximum of 1200 watts. (This circuit should come from the same AC Distribution panel that powers the AUDIX, and power should not be controlled by the switch. The circuit should not share power with room lighting or other electrical devices that could cause electrical interference.)

A power strip should be installed at the back of the cabinet along the bottom left-hand side. The vertical side rails on the left and right sides of the cabinet go in the ???fth hole from the front. The equipment mounting ???anges on the rails face the front.

Install the Multiple Mountings

Each mounting plugs into the cabinet power strip and will draw 52 watts of power. The mountings operate in an ambient temperature range of 40 to 120 degrees F (4.44 to 48.8 degrees C) and a relative humidity range of 5 to 95 percent, noncondensing. The altitude limit is 10,000 feet above sea level.

Figure 11-1, 72-Inch Data Cabinet and Multiple Mountings, shows how the mountings are to be installed. The 105A mounting can be modi???ed to ???t in a 19- or 23-inch space by changing bracket positions.

11-1

11-2 DCP Mode 2 Installation and Administration

________________________________________________________________________________________________

________________________________________________________________________________________________

Test-???t an empty mounting between the rails and determine which holes in the rails will be used. Leave 1/2 inch between mountings. Start a screw in each of these holes, leaving 1/4-inch gap between the screw-head and rail. Install the mounting using the screws as hooks to hold it in place. Start a screw at the top of each side of the mounting and tighten. Tighten the bottom screws.

SIDE RAILS

105A MOUNTING

WITH 8 MODEMS

77A MOUNTING

WITH 8 DATA SETS

105A MOUNTING

WITH 8 MODEMS

77A MOUNTING

WITH 8 DATA SETS

NOTE: Use 46A2 mounting if MTDMs are used instead of 7400As.

Figure 11-1. 72-Inch Data Cabinet and Multiple Mountings

Install the Modems and Data Sets

Each modem and data set plugs into the mounting and will draw 30 watts of power. The modems and data sets also operate in an ambient temperature range of 40 to 120 degrees F (4.44 to 48.8 degrees C) and a relative humidity range of 5 to 95 percent, noncondensing. The altitude limit is 10,000 feet above sea level.

_______________________________________________________________________________________

_______________________________________________________________________________________

Figure 11-2, Modem Pooling Cabinet with MTDMs (Front View), shows the front of a 105A and a 46A2 mounting. The shared Liquid Crystal Display (LCD) front panel of the 105A is for setting options inside each modem. The MTDMs require a 46A2 mounting (shown in Figure 11-2). The 7400A data sets require a 77A mounting (shown in Figure 11-5 Installation procedures for the 7400A are given in the 7400A DSU Installation and Settings (D-Lead Control) section later in this chapter.

Figure 11-2. Modem Pooling Cabinet with MTDMs (Front View)

11-4 DCP Mode 2 Installation and Administration

________________________________________________________________________________________________

________________________________________________________________________________________________

Use the following steps to install the modems and data sets.

1.Before installing a 2296A modem, check the feature package module located in the right-hand slot (modem standing on end). This should be a 140C1 (V1.1 or V1.2 no longer purchasable), 140F (V1.1), or 140F2 (V1.0) Memory Module.

CAUTION

Do not pull the feature package or other module from the 2296A when power is applied. Turn the power switch at the back of the 2296A OFF and unplug the 2296A power cord from the mounting.

The Automatic Calling Unit (ACU) and AUTOCALL modules are not required and should be removed if present. The Microcom Networking Protocol (MNP) module is only required if the data rate is 19.2 Kbps. In most AUDIX modem-pooling setups, the data rate is 9600 bps.

2.Install the 2296A modems in 105A slots. Start at the left. The modems must contact their backplane connector. Set the following options located at the top of the 2296A faceplate under the sliding panel:

The LCD display will be used to set internal options once power is applied.

3.Before installing the MTDMs, verify that they contain the new processor and TRIC 4 chips (see Figure 11-3, MTDM Location of TRIC 4 Chips). If not, they must be upgraded before they can be used. See Chapter 5, DCP Mode 2 Networks ??? Modem Pooling, for upgrades.

4.Set the following options on the MTDM circuit card:

5.Install the MTDM data sets in 46A2 slots. Start at the left. Each MTDM is paired with a modem. The MTDMs must make contact with the backplane connector.

_______________________________________________________________________________________

_______________________________________________________________________________________

VERIFY THAT THE DAUGHTER

BOARD USES TRIC 4 CHIPS (CODED 229EJ)

JUMPER NO. 9 PLACED IN NEW

POSITION AS SHOWN (SEE IC3

EXPLODED VIEW BELOW)

IC4 FROM

D181470

Figure 11-3. MTDM Location of TRIC 4 Chips

6.Set the following options on the face of the MTDM. The arrows (< for left, > for right) indicate which direction the rockers should be set. The speed shown is 9600 bps.

_________________________________________

11-6 DCP Mode 2 Installation and Administration

________________________________________________________________________________________________

________________________________________________________________________________________________

???

???

???

???

???

???

???

???

???

???

???

???

???

???

???

???

???

???

???

???

Install the Multi-Mount Cables

Figure 11-4, Modem Pooling Cabinet Cabling, shows the rear view of the modem-pool cabinet. Cables should be installed as shown. For details, see the following procedures:

1.Connect the D Lead Control cable (RS-232C to 25-pair) from the DATA MODE CONTROL connector on the 105A to the MODEM CONTROL connector on the 46A2.

2.Connect one end of a 25-pair cable to the RJ21X PERMISSIVE connector on the 105A.

3.Connect the other end of this cable to the switch cross-connect ???eld. Use the following table to patch a tip and ring pair to a switch analog port.

Record the telephone number of each modem on the space above the display panel.

_______________________________________________________________________________________

_______________________________________________________________________________________

ONE OF 8

NOTE: This ???gure shows the MTDM rack on top.

Figure 11-2 shows it on bottom.

Figure 11-4. Modem Pooling Cabinet Cabling

11-8 DCP Mode 2 Installation and Administration

________________________________________________________________________________________________

________________________________________________________________________________________________

4.The switch to the right of the RJ21X PERMISSIVE connector must be in the down position.

5.Set the eight Make Busy/Enable switches to the enable position (DOWN).

6.Connect one end of a 25-pair cable from the DCP LINE connector on the 46A2.

7.Connect the other end of this cable to the switch cross-connect ???eld. Use the following table to patch a 4-wire DCP LINE circuit to a switch digital port (GPP) circuit. The switch ports use the same wire combinations.

8.Connect a ground strap from the signal ground (SG) to the frame ground (FG) on the 105A.

9.Make sure the cabinet is not connected to power, then connect the mounting power cords to the cabinet power strip.

_______________________________________________________________________________________

_______________________________________________________________________________________

Install the MTDM and 2296A Cables

1.Connect a Data Terminal Equipment (DTE) RS-232C cable from the back of each 2296A (data port) to the back of its paired MTDM (RS-232C connector at bottom).

2.At the back of the modem, make sure the power switch is OFF (0 position).

3.At the back of the mounting, connect one of the eight power cords to the AC power jack on the back of the modem.

2296A Option Settings (D-Lead Modem Pool)

1.First make sure that the power switch for each MTDM and each 2296A is OFF.

2.Plug the cabinet power cord into the circuit provided. The LCD display on the front of the 105A should light up.

3.Turn the power switch at the back of the modem ON (1).

4.Press the select button on the front of the mounting below the modem to be optioned. The button should light up and the display will show the information for this modem.

5. Press MENU SEL until OPt is displayed.

6. Press . (dot) once.

15.Set option 99 to 2 to relock this modem???s options.

11-10 DCP Mode 2 Installation and Administration

Figure 11-5. Modem Pooling Cabinet with 7400As Front View

_______________________________________________________________________________________

_______________________________________________________________________________________

INSTALLING A 7400A IN A MODEM POOL

The 7400A Data Service Unit (DSU) can replace the MTDM in modem pooling applications on a System 75, System 85, DEFINITY Generic 1, Generic 2, or Generic 3. Instructions for installing a 7400A DSU in the D-lead controlled (rack-mounted) modem pool instead of an MTDM are summarized in this section. To install the 7400A in a stand-alone modem pool, see the next section, Installing Stand-Alone Modem Pools.

1.Disconnect the power cord, the line cord, and the RS-232 cable from the 7400A.

2.Open the top door of the 7400A by inserting the tip of a ball-point pen into the small hole near the LINE label on the back panel. Push in on the tab on the hole while pulling up on that side of the door. Repeat the procedure for the other side of the door. Lift off the door and set it aside.

3.Rotate the 7400A so that you are viewing it from the front. Look straight down at the inside and locate the large silver arrow pointing toward the back of the set. The arrow points to the EIA connector board. The board is perpendicular to the plane of the arrow. You can see it at the point of the arrow.

4.Look at the EIA board from the front of the set. You should see DTE printed on the left hand corner of the board. If you see DCE, pull the board up until it is completely free. Rotate it until you can read DTE from the front of the 7400A and plug the board in again.

5.Close the door by hooking the hinges under the front housing and then snapping the rear tabs into place.

6.Check the position of the slide switch located near the front of the access door opening. It should be positioned to the left as viewed from the front of the unit (position B). This is the normal position for operation in a modem pool. There are some 9600 bps modems which will not operate properly with the switch in this position, particularly those modems employing data compression and error correction (such as the Hayes SMARTMODEM 9600). For these modems, position the switch to the right (position A).

7.Plug one end of the D8W-87 from the adapter harness into the labeled line (see step 13 for information on the adapter harness).

8.Plug the power supply cord into the receptacle labeled POWER on the 7400A.

9.Plug one end of the EIA-232-D cable into the port labeled PORT 1 on the 7400A, and the other end into the EIA port on the modem.

10.Make sure that your PBX is administered to support the 7400A in a modem pool arrangement. See the 7400A Modem Pool Installation Guide (555-020-708).

11.Plug the power supply into an AC power outlet.

12.Use the front panel to set the 7400A options according to the following table. See the 7400A Data Module User???s Manual (505-020-706) for details.

11-12 DCP Mode 2 Installation and Administration

________________________________________________________________________________________________

________________________________________________________________________________________________

* To enable stepdown (slower data transmission speed), set 4800 speed to ON. On the modem, set Options 50, 56, and 73 to y.

Continue the installation according to the following steps. The 7400A is con???gured for DTE modem pool operation with D-lead controlled 2296-type modems. The mounting package includes an adapter harness (WP90780L0), an OR-6316 bridging adapter, and a 2296 modem control cable (D- Lead).

13.Connect the 50-pin connector on the adapter harness to P1 on the bridging adapter [see Figure 11-6,

AUDIX Networking (Modem Pooling) With 7400A DSUs]. Then plug each numbered connector (D8W-87 cords) on the harness into the LINE jack on the corresponding 7400A (see the numbered slots on the mounting rack).

14.Connect the 25-pair cable from the switch to J1 on the bridging adapter. For correct wiring of the switch cable, see the table titled WP90780L0 25-Pair Cable Adapter for Use with Direct Cabling to Multiple Mount for DCP Installations in the 7400A Data Module User???s manual.

15.Connect the 50-pin plug of the D-Lead cable to J2 on the bridging adapter.

16.Put the cover on the bridging adapter.

17.Connect the other end of the D-Lead cable to the Data Mode Control connector on the modem rack.

Figure 11-6. AUDIX Networking (Modem Pooling) with 7400A DSUs

18.From the back of the rack, connect the appropriate M25B cable to its RS-232 port on the back of each data module. Tighten the connector screws to hold the cables securely in place.

19.Drape each interface cable through its plastic twist lock and twist the top ends of the lock to secure each cable. Make sure each modem is interconnected through the RS-232 cable to the 7400A in the corresponding rack position.

20.To test the remote connection and the administration of the system, run the self-test as described in Section 2 of the 7400A Data Module User???s manual.

11-14 DCP Mode 2 Installation and Administration

________________________________________________________________________________________________

________________________________________________________________________________________________

INSTALLING STAND-ALONE MODEM POOLS

Stand-alone modem pools can be used with System 75, System 85, Generic 1, Generic 2, and Generic 3. Although cabled as a stand-alone modem pool, the modems and data sets can still be mounted in racks if you have spare rack-type units that must be utilized.

System 75/85, System 75 XE, Generic 1, Generic 2, and Generic 3

If the AUDIX is equipped with the TN366B, TN539, or TN539B stand-alone modems and data sets can be used instead of the equipment associated with a switch???s modem pool (that is, data cabinet, mountings, and D-Lead control). Use one of the following modems along with a 7400A DSU:

???AT&T Paradyne 3820 modem

???AT&T Paradyne DM424 modem

???AT&T 2296A modem

NOTE

Equivalent modems such as the AT&T Paradyne DL424 instead of the DM424 modem could be used.

Figure 11-7, Analog Network Using Stand-Alone Modems and Data Sets, shows how the modem and data set are cabled. Check the modem and data set options before installing them. Options are given on the following pages. The 7400A requires power from a rack-mount or from a separate unit.

104A

MODEM

M25B RS-232 (M/M)

Figure 11-7. Analog Network Using Stand-Alone Modems and Data Sets

_______________________________________________________________________________________

_______________________________________________________________________________________

2296A Modem AUTOCALL Dialer Module, Type 2A4

The 2296A requires a dialer module when in a stand-alone modem pool. Follow these instructions before installing the modem.

1.Disassembling the Modem:

a.Make sure power is turned OFF.

b.Disconnect all cords from the modem.

c.Turn the modem upside down and remove the six recessed screws along the edges of the modem.

d.Hold the top and bottom halves of the housing together as you turn the modem right-side up.

e.Gently remove the top half of the housing.

f.Disconnect the ribbon cable that connects the front panel to the right side of the circuit pack (when facing the front of the modem).

g.Remove the front panel by lifting it straight up.

h.Lift the front of the circuit pack about 1 inch, pull the circuit pack forward about 1 inch, and set it down.

2.Inserting the Dialer:

a.At the side of the modem???s circuit pack labeled EXPANSION SLOT A, tilt the circuit pack up from the housing until the slot is visible (1 or 2 inches up).

b.Orient the dialer module with the metal tab toward the rear of the modem circuit pack. Insert the dialer module in EXPANSION SLOT A.

When fully inserted, the hole in the metal tab should be positioned over a threaded hole in the modem???s circuit pack.

c.Move the modem???s circuit pack back to its original position with the connectors at the rear extending through the back of the housing. Make sure the notches cut into the sides of the circuit pack align with the supports in the housing.

d.Fasten the dialer module in place with the screw shipped with the module.

e.Keep a record of which dialer module is installed (AUTOCALL DIALER).

3.Assembling the Modem:

a.Place the front panel back in the housing. Insert the bottom (hinged side) of the panel ???rst, then rotate the front panel back into place.

b.Reconnect the ribbon cable to the connector on the right side of the modem???s circuit pack. Make sure the cable does not get in the way when replacing the top half of the housing and installing the screws.

c.Replace the top half of the housing. Check the front and rear panels to be sure that the housing is positioned correctly.

d.Hold the top and bottom halves of the housing while turning the modem over.

e.Install the six screws and tighten.

11-16 DCP Mode 2 Installation and Administration

________________________________________________________________________________________________

________________________________________________________________________________________________

2296A Modem Option Settings (Stand-Alone Modem Pool)

All 2296A modems now are shipped with a memory module. In earlier versions, a 140C1 Memory Module V1.1 or V1.2 had to be installed in the right-hand slot at the bottom. New modems have a 140F2 module which will work. The 2296A modem does not need the optional ACU board. If the data speed is slower than 19.2 Kbps, the MNP board is also not needed.

Two groups of switches are located at the top of the 2296A modem faceplate. Set the switches according to the following table:

For instructions on how to set the 2296A option settings from the front panel, see 2296A Option Settings (D-Lead Modem Pool) earlier in this chapter. Below is a summary:

???Set Option 99 to 1 (allows options to be changed).

???Set all options to their default.

???Set Option 50 (async/sync) to y.

???Set Option 56 (Early DSR) to y.

???Set the speed to 9600 (same as the MTDM).

???Set Option 99 back to 2 (two).

To set the options from a terminal, use the follow initialization string:

at&f x1 v0 m0 e0 &c1 &d2 &s1 s0=2 &w RETURN

If successful, the response will be 0. A response of anything other than 0 indicates a fail.

_______________________________________________________________________________________

_______________________________________________________________________________________

DM424 Modem Option Settings (Stand-Alone Modem Pool)

Only switch 6 should be in the ON (DOWN) position. There is also a DIP switch at the back of the modem. All DIP switches should be in the OFF (UP) position. If you change any setting, make sure power is cycled. This will activate the new setting(s).

The modem initialization string must be entered manually from the keyboard of a 9600 bps terminal interface. If possible, use a terminal that does not require Data Set Ready (DSR) to be active; however, most terminals (including the 513 BCT and TELETYPE 5420) require that DSR be active at the modem in order for them to send characters to it. The DM424 modem has DSR active from the factory, but once the following initialization string is sent, DSR becomes inactive. [The ??????&b2?????? required for stand-alone modem pool operation deactivates DSR, even though the Modem Ready (MR) lamp would indicate otherwise.]

If you are using a terminal that requires DSR to be active and you need to resend the initialization string for any reason, or if you want to receive a response as to whether the initialization was successful, you need to ???rst insert an RS-232 breakout box as described in the RS-232 Breakout Box section.

The initialization string required for the DM424 follows. Spaces have been inserted to improve readability; they are ignored by the command interpreter.

at&f *s0 *e0 &b2 x1 v0 m0 e0 &w RETURN

The terminal screen will show whether the initialization was successful (if you are using a terminal that requires DSR to be active, you need to have inserted an RS-232 breakout box in order to see the response). A successful response is 0. A response of anything other than 0 indicates a fail.

Paradyne 3820 Modem Option Settings (Stand-Alone Modem Pool)

The modem initialization string must be entered manually from the keyboard of a 9600 bps terminal interface. If possible, use a terminal that does not require Data Set Ready (DSR) to be active; however, most terminals (including the 513 BCT and TELETYPE 5420) require that DSR be active at the modem in order for them to send characters to it. The Paradyne 3820 modem has DSR active from the factory, but once the following initialization string is sent, DSR becomes inactive. [The ??????&s1?????? required for stand- alone modem pool operation deactivates DSR, even though the Modem Ready (MR) lamp would indicate otherwise.]

If you are using a terminal that requires DSR to be active and you need to resend the initialization string for any reason, or if you want to receive a response as to whether the initialization was successful, you need to ???rst insert an RS-232 breakout box as described in the RS-232 Breakout Box section.

The initialization string required for the Paradyne 3820 follows. Spaces have been inserted to improve readability; they are ignored by the command interpreter.

at&f0 &d2 &s1 \d3 \n0 e0 v0 x1 s41=3 s43=1 s76=1 s78=1 &w0 RETURN

The terminal screen will show whether the initialization was successful (if you are using a terminal that requires DSR to be active, you need to have inserted an RS-232 breakout box in order to see the response). A successful response is 0. A response of anything other than 0 indicates a fail.

11-18 DCP Mode 2 Installation and Administration

________________________________________________________________________________________________

________________________________________________________________________________________________

RS-232 Breakout Box

If you are using a terminal that requires DSR to be active (for example, a 513 BCT or TELETYPE 5420), you must install an RS-232 breakout box if you want to resend an initialization string or receive a response as to whether or not an initialization was successful (this is because the ???rst initialization string you send turns DSR off).

To install the RS-232 breakout box:

1.Insert the breakout box in the RS-232 connection between the terminal and the modem.

2.Using the switches on the breakout box, open Pin 6 (DSR).

3.Jumper Pin 6 on the terminal side to +v on the breakout box. This will provide DSR active to the terminal.

6.Re-enter the initialization string.

7.Remove the breakout box and reconnect the modem to the modem pool.

Stand-Alone Modem Cabling

To install cabling, do the following:

1.Connect an M25B RS-232 (male to male) cable between the modem and the 7400A.

2.Connect the modular cord that comes with the modem to the back of the modem and to one side of a 104A connecting block.

3.Connect the D8W-87 cord that comes with the data set between the data set and the other side of the 104A connecting block.

4.Wire the connecting block to the ports on the switch. Wire the modem to the analog port and wire the 7400A to the digital port.

_______________________________________________________________________________________

_______________________________________________________________________________________

7400A DSU Option Settings (Stand-Alone Modem Pool)

The 7400A has an internal DCE/DTE card. The DTE side should be facing the front of the set. Set the following options when the 7400A is installed in a stand-alone modem pool. Use the buttons on the front panel. Start by pressing NEXT .

11-20 DCP Mode 2 Installation and Administration

________________________________________________________________________________________________

________________________________________________________________________________________________

ADMINISTERING THE SWITCH FOR MODEM POOLING

This section describes switch administration for a System 75, System 85, or DEFINITY Generic 1, Generic 2, or Generic 3.

If you are adding modem pool members, ???ll in the following before starting. For System 75, System 75 XE, Generic 1, Generic 2 (universal module), and Generic 3, locate the TN circuit packs shown below. For System 85 and Generic 2 (traditional module), locate the SN packs:

???TN754 or SN270B connected to MTDM-1 ____________________ (equipment location)

???TN754 or SN270B connected to MTDM-2 ____________________ (equipment location)

???TN754 or SN270B connected to MTDM-3 ____________________ (equipment location)

???TN754 or SN270B connected to MTDM-4 ____________________ (equipment location)

???TN742/TN746B or SN243B connected to 2296A-1 ____________________ (equipment location)

???TN742/TN746B or SN243B connected to 2296A-2 ____________________ (equipment location)

???TN742/TN746B or SN243B connected to 2296A-3 ____________________ (equipment location)

???TN742/TN746B or SN243B connected to 2296A-4 ____________________ (equipment location)

NOTE

On System 75, Generic 1, or Generic 3, lines (or stations) and trunks can reside on the same board for analog circuits. For digital circuits, lines and trunks should not reside on the same pack or the modem-pool setup may experience dif???culty.

On System 85 or Generic 2, only modem-pooling trunks can be assigned to one analog or digital board (you cannot mix trunks and lines for modem-pooling circuits).

System 75, Generic 1, and Generic 3 Administration

Use the following steps to administer the switch for modem pooling:

1.Using change system-parameters feature, set Off-Premises Tone Detect Timeout Interval to 25 seconds.

2.Using add modem-pool next (for System 75 or Generic 1) or add modem-pool xxxx (for Generic 3, where xxxx is the next available number), set Group Type to combined and press

ENTER . The screen will be ???lled in as shown in Figure 11-8, System 75, Generic 1, and Generic 3 Modem Pool Assignments.

Make the entries as shown. Analog and digital assignments correspond to the equipment locations of the TN742 or TN746B and the TN754 circuits, respectively. When all entries are made, press

ENTER .

_______________________________________________________________________________________

_______________________________________________________________________________________

add modem-pool next

Figure 11-8. System 75, Generic 1, and Generic 3 Modem Pool Assignments

System 85 Administration

Use the following steps to administer a System 85 for modem pooling using a MAAP:

1.Assign a bearer capability of mode 0 data to the class of service for the AUDIX networking extensions (Proc 010, Word 4, Field 3 = 4).

2.Procedure 100, Word 1 (for the digital side):

a.Enter the trunk group number (tgroup1) in Field 1. A dial access code is not required (Fields 2 through 5).

b.Set Trunk Type to 102 (Field 6 = 102).

c.Set Dial Access Restriction to 0 (Field 7 = 0).

d.Set CO Line Appearance to 0 (Field 8 = 0).

11-22 DCP Mode 2 Installation and Administration

________________________________________________________________________________________________

________________________________________________________________________________________________

3.Procedure 100, Word 2 (for the digital side):

a.Enter the trunk group number (tgroup1) in Field 1.

b.Set the data rate for each speed optioned for the data modules in the modem pool in Fields 2 through 10.

NOTE

A data rate of 64 Kbps should always be translated for the modem pool in addition to the data rates optioned on the data module; this will ensure that a modem pool is selected when an incoming data call is directed to an AUDIX DCP port. If 64 Kbps is not translated, the modem-pool setup may not work, or may not recover after a failure.

c.Set Synchronous to 0 for asynchronous operation (Field 11 = 0).

d.Set Duplex to 0 for full duplex (Field 12 = 0).

e.Set Modem Pool Mode - Originate to 1 (Field 13 = 1).

f.Set Modem Pool Mode - Answer to 1 (Field 14 = 1).

g.Set Modem Pool - Modem Type to 1 (Field 15 = 1).

h.Set Modem Pool - Clock to 0 (Field 16 = 0).

i.Set Modem Pool - First Choice to 1 (Field 17 = 1).

j.Set Test Type to 0 (to turn off periodic on-line testing) or 1 (to allow periodic on-line testing) (Field 18). Currently only R2V3 systems should have Field 18 set to 1. On other systems, Field 18 should be 0.

k.Set Host Access Clock to 0 (Field 19 = 0).

* = data rate (translate 64 Kbps in addition to optioned rates, usually 9600 bps) $ = test type (see item j above)

4.Procedure 100, Word 1 (for the analog side):

a.Enter the trunk group number (tgroup2) in Field 1. A dial access code is not required (Fields 2 through 5).

b.Set Trunk Type to 101 (Field 6 = 101).

c.Set Dial Access Restriction to 0 (Field 7 = 0).

d.Set CO Line Appearance to 0 (Field 8 = 0).

_______________________________________________________________________________________

_______________________________________________________________________________________

5.Procedure 180, Word 1:

a.Enter the digital trunk group number (tgroup1) in Field 1.

b.Set Digital Equipment Location to one of the digital trunk circuits (Fields 3 through 7).

c.Set Analog Trunk Group to the analog trunk group number (Field 8).

d.Set Analog Equipment Location to the analog trunk circuit (Fields 9 through 13) paired with the digital trunk circuit of Fields 3 through 7.

Modem Pooling Testing

After assigning modem pooling on System 85 or Generic 2, test the modem-pooling facilities as follows:

1.Use Procedure 100, Word 2 to enable demand testing:

On System 85: Set Field 18 to 1 (if it is displaying a 0).

On Generic 2: Set Field 7 to 1 (if it is displaying a 0).

2.Use Procedure 646 to test the modem pool:

a. Press NEXT TEST once (Field 1 = 2).

b.In Field 2, enter a ???0???.

c.In Field 3, enter the digital or analog trunk group number.

3.Use Procedure 100, Word 2 to disable demand testing (if you changed Field 7 or 18 to 1 prior to testing):

On System 85: Set Field 18 back to 0 (if it was previously displaying a 0).

On Generic 2: Set Field 7 back to 0 (if it was previously displaying a 0).

4.Use Procedure 620 to test the analog facilities: Run Test 2 on the analog circuits (SN243B).

5.Use Procedure 622 to test the digital facilities:

Run Test 2 on the digital circuits (SN270B or TN754).

11-24 DCP Mode 2 Installation and Administration

________________________________________________________________________________________________

________________________________________________________________________________________________

Generic 2 Administration

The following Manager II translations need to be completed on Generic 2 to implement modem pooling.

NOTE

DEFINITY Manager III and Manager IV are covered in their own documentation sets. Refer to the list of documents in Chapter 9 to ???nd the appropriate manual for administering systems using Manager III or Manager IV.

1.Using Procedure 100, Word 1, make the assignments shown in Fields 1 through 9 for the digital side of the modem pool. Refer to Figure 11-9, Manager II Administration for Digital Side of Modem Pooling (Proc 100, Word 1).

The trunk group (130) and the dial access code/trunk ID code shown are only examples; enter the appropriate values supplied by the BCSDC.

ENHANCED MODE - PROCEDURE: 100, WORD: 1

TRUNK GROUP TRANSLATION

1. Trunk Group: 130

DIAL ACCESS CODE/TRUNK ID CODE

2.Digit 1: 2

3.Digit 2: 1

4.Digit 3: 5

5.Digit 4: -

6.Trunk Type: 102 Digital data modem pool (18)

7.Dial Access Restriction: 0 Access is allowed using DAC

8.Personal CO Line Appearance: 0 Not used for CO line appearance

9.Public Network Access/Egress: 0 Disabled

Figure 11-9. Manager II Administration for Digital Side of Modem Pooling (Proc 100, Word 1)

_______________________________________________________________________________________

_______________________________________________________________________________________

2.Using Procedure 100, Word 2, make the assignments shown in Fields 1 through 7. Assign a custom BCCOS to the trunk group (trunk group 130 and a custom BCCOS of 10 are shown only as examples). The custom BCCOS should mirror the default BCCOS 1 as shown in Figure 11-10,

Manager II Administration for Digital Side of Modem Pooling (Proc 100, Word 2).

NOTE

Refer to the DEFINITY Generic 2 Administration Procedures manual (555-104-506)

for the default values of BCCOS 1 if needed.

ENHANCED MODE - PROCEDURE: 100, WORD: 2

TRUNK GROUPS - MODEM POOLING AND BCCOS

MODEM POOLING

3.Originate Mode: 1

4.Answer Mode: 1

5.Modem Type: 1

6.First Choice: 1

7.Test Type: 0

Figure 11-10. Manager II Administration for Digital Side of Modem Pooling (Proc 100, Word 2)

11-26 DCP Mode 2 Installation and Administration

________________________________________________________________________________________________

________________________________________________________________________________________________

3.Using Procedure 014, assign a custom BCCOS that is translated with all the speeds optioned for the data modules in the modem pool. The custom BCCOS should mirror the default BCCOS 1 except for the data rates chosen (BCCOS 1 automatically defaults to all speeds.)

In Figure 11-11, Manager II Administration for Digital Side of Modem Pooling (Proc 014, Word 1), a custom BCCOS of 10 is shown as an example only.

ENHANCED MODE - PROCEDURE: 014, WORD: 1

BEARER CAPABILITY CLASS OF SERVICE - CALL OPTIONS

CALL TYPES AND ACTION TAKEN

4.Voice: 0 Circuit switch the call

5.Voice Grade Data: 1 Insert a mode 2-to-analog modem pool facility

6.Mode 0: 0 Circuit switch the call

7.Mode 1: 0 Circuit switch the call

8.Mode 2: 0 Circuit switch the call

9.Mode 3: 0 Circuit switch the call

10.Unknown Digital: 0 Circuit switch the call

11.Unknown Analog: 1 Insert a mode 2-to-analog modem pool facility

12.Mode 3/2: 0 Circuit switch the call

13.X.25: 0 Circuit switch the call

Figure 11-11. Manager II Administration for Digital Side of Modem Pooling (Proc 014, Word 1)

_______________________________________________________________________________________

_______________________________________________________________________________________

4.Using Procedure 014, Word 2, select the data rates that will be used by the data modules in the modem pool. Figure 11-12, Manager II Administration for Digital Side of Modem Pooling (Proc 014, Word 2), shows data rates of 64 Kbps and 9600 bps and a custom BCCOS of 10 (these values are shown as examples only).

NOTE

A data rate of 64 Kbps should always be translated for the modem pool in addition to the data rates optioned on the data module; this will ensure that a modem pool is selected when an incoming data call is directed to an AUDIX DCP port. If 64 Kbps is not translated, the modem-pool setup may not work, or may not recover after a failure.

ENHANCED MODE - PROCEDURE: 014, WORD: 2

BEARER CAPABILITY CLASS OF SERVICE - DATA OPTIONS

1. Bearer Capability COS: 10

DATA RATE

2.64000 bps: 1 Supported

3.56000 bps: 0 Not supported

4.19200 bps: 0 Not supported

5.9600 bps: 1 Supported

6.4800 bps: 0 Not supported

7.2400 bps: 0 Not supported

8.1200 bps: 0 Not supported

9.300 bps: 0 Not supported

10.Low Speed: 0 Not supported

11.Synchronous: 0 Asynchronous

12.Duplex: 0 Full duplex

13.Clock: 0 Internal

14.Default Data Rate: 9 64000 bps

Figure 11-12. Manager II Administration for Digital Side of Modem Pooling (Proc 014, Word 2)

11-28 DCP Mode 2 Installation and Administration

________________________________________________________________________________________________

________________________________________________________________________________________________

5.Using Procedure 100, Word 1, make the assignments shown in Fields 1 through 9 for the analog side of the modem pool. Refer to Figure 11-13, Manager II Administration for Analog Side of Modem Pooling (Proc 100, Word 1).

The trunk group (131) and the dial access code/trunk ID code shown are only examples; enter the appropriate values supplied by the BCSDC.

ENHANCED MODE - PROCEDURE: 100, WORD: 1

TRUNK GROUP TRANSLATION

1. Trunk Group: 131

DIAL ACCESS CODE/TRUNK ID CODE

2.Digit 1: 2

3.Digit 2: 1

4.Digit 3: 5

5.Digit 4: -

6.Trunk Type: 101 Analog data modem pool (27)

7.Dial Access Restriction: 0 Access is allowed using DAC

8.Personal CO Line Appearance: 0 Not used for CO line appearance

9.Public Network Access/Egress: 0 Disabled

Figure 11-13. Manager II Administration for Analog Side of Modem Pooling (Proc 100, Word 1)

_______________________________________________________________________________________

_______________________________________________________________________________________

6.Using Procedure 100, Word 2, make the assignments shown in Fields 1 through 7. Assign BCCOS 5 to the trunk group (trunk group 131 is only an example). Refer to Figure 11-14, Manager II Administration for Analog Side of Modem Pooling (Proc 100, Word 2).

NOTE

BCCOS 5 is the default and should not be modi???ed. However, if BCCOS 5 has been modi???ed at your site, use a custom BCCOS that has the default values of BCCOS 5. Refer to the DEFINITY Generic 2 Administration Procedures manual (555-104-506) for default BCCOS values if needed.

ENHANCED MODE - PROCEDURE: 100, WORD: 2

TRUNK GROUPS - MODEM POOLING AND BCCOS

MODEM POOLING

3.Originate Mode: -

4.Answer Mode: -

5.Modem Type: -

6.First Choice: -

7.Test Type: -

Figure 11-14. Manager II Administration for Analog Side of Modem Pooling (Proc 100, Word 2)

11-30 DCP Mode 2 Installation and Administration

________________________________________________________________________________________________

________________________________________________________________________________________________

7.Use Procedure 180, Word 1 to pair up the digital trunk group with the analog trunk group.

Use appropriate entries for this procedure. The trunk groups shown (130 and 131) are only examples.

ENHANCED MODE - PROCEDURE: 180, WORD: 1

Figure 11-15. Manager II Administration for Modem Pool Pair (Proc 180, Word 1)

12. DCP Mode 3 Installation and Administration

_______________________________________________________________________________________

_______________________________________________________________________________________

Digital Communications Protocol (DCP) Mode 3 uses 64 Kbps, end-to-end, packet-mode operation for data transmission. It may be used in the following setups:

???Local Networking: If you are installing a DCP Mode 3 network for two or more colocated (local) AUDIX systems (the AUDIX systems are connected to the same switch), refer to Chapter 9, DCP Cabling and Administration. There you install and translate each AUDIX system with the extension numbers required for each network channel. There are no requirements except extension numbers for a local AUDIX network.

???Remote Networking: If you are installing a DCP Mode 3 network that requires interlocation facilities, these facilities are typically T1 Carrier employing common (clear) channel signaling or an Integrated Systems Digital Network (ISDN) pipe.

This chapter covers administration and testing for DCP Mode 3 AUDIX networking setups.

SWITCH COMPONENT INSTALLATION

See the appropriate switch and/or feature documentation for installing circuit packs and wiring trunks on the switch.

SWITCH ADMINISTRATION

See the appropriate switch and/or feature documentation for ISDN administration. For DS1 administration of either local or remote AUDIX networking setups, see the following sections.

System 75, Generic 1, and Generic 3 Administration

The DS1 circuit pack uses the Common Channel Signaling mode to provide 23 trunks for data transmission and one channel for signaling. The DS1 trunk group must be assigned for AV/D.

At this time, use standard AV/D DS1 administration. Any speci???c assignments that become necessary for AUDIX networking will be covered in future issues of this document.

12-1

12-2 DCP Mode 3 Installation and Administration

________________________________________________________________________________________________

________________________________________________________________________________________________

System 85 Administration

The DS1 circuit pack uses the Common Channel Signaling mode to provide 23 trunks for data transmission and one channel for signaling. The DS1 trunk group must be assigned for AV/D using the following MAAP procedures.

1.For local and remote AUDIX setups: Assign a bearer capability of mode 0 data to the class of service for the AUDIX networking extensions (Proc 010, Word 4, Field 3 = 4).

2.Assign a trunk group and trunk type using Procedure 100, Word 1. Assign members to the trunk group using Procedure 116.

3.For remote AUDIX setups only: The trunk group used to transport the AUDIX networking call must be DS1, and the DS1 pipe must employ 24th channel signaling.

a.Enter the trunk group number (tgroup) in Field 1.

b.Make sure Touch Tone In and Touch Tone Out are set to 1 (Fields 6 and 7 = 1).

c.AVD must be set to 1 (Field 17 = 1).

4.For remote networking con???gurations using AAR or ARS: If the local AUDIX DCP extensions dial AAR or ARS to reach a remote AUDIX system, make sure the FRL assigned to the AUDIX networking extensions??? cos is of a suf???cient value to get over the pattern and preference to allow calls from mode 0 data endpoints (Proc 309, Word 5, Field 10 = 1, or Proc 321, Word 5, Field 9 = 1).

Generic 2 Administration

This section describes the Manager II translations that must be completed on Generic 2 to implement DCP Mode 3 networking on AUDIX systems.

NOTE

DEFINITY Manager III and Manager IV are covered in their own documentation sets. Refer to the list of documents in Chapter 9 to ???nd the appropriate manual for administering systems using Manager III or Manager IV.

1.For local and remote AUDIX setups: You should have already assigned BCCOS 6 to the AUDIX DCP extensions in Chapter 9. Refer to Chapter 9 if necessary and check Figure 9-5, Manager II Administration of a DCP Port (Proc 000, Word 3).

2.For remote AUDIX setups only: The trunk group used to transport the AUDIX networking call must be DS1, and the DS1 pipe must employ 24th channel signaling.

_______________________________________________________________________________________

_______________________________________________________________________________________

Using Procedure 100, Word 2, assign BCCOS 3 to the DS1 trunk group to provide 64K clear-channel signaling (trunk group 77 is only an example).

If BCCOS 3 has been modi???ed at your site, use a custom BCCOS that has the default values of BCCOS 3. Refer to the DEFINITY Generic 2 Administration Procedures manual (555-104-506) for default BCCOS values if needed.

ENHANCED MODE - PROCEDURE: 100, WORD: 2

TRUNK GROUPS - MODEM POOLING AND BCCOS

MODEM POOLING

3.Originate Mode: _

4.Answer Mode: _

5.Modem Type: _

6.First Choice: _

7.Test Type: _

Figure 12-1. Manager II Mode 3 Administration (Proc 100, Word 2)

3.For remote networking con???gurations using AAR or ARS: If the local AUDIX DCP extension is dialing AAR or ARS to reach a remote AUDIX system, the appropriate pattern and preference must indicate BCCOS 3 (Proc 309, Word 5, Field 6 = 3, or Proc 321, Word 5, Field 5 = 3).

12-4 DCP Mode 3 Installation and Administration

________________________________________________________________________________________________

________________________________________________________________________________________________

LOOPBACK TESTING FOR INTERLOCATED SYSTEMS

If the AUDIX systems to be networked are at different locations (interlocated) and a serving of???ce (SO) will provide 64 Kbps service, you will need to test the connection between the local AUDIX system and the 64 Kbps serving of???ce (SO), as shown in Figure 12-2, 64 Kbps Network Loop-Around Test. If you have R1V7 software, you can do this via the maintenance : network form for the DCP ports (ports 1-4). If you have an MPDM/M1* connected to ports 5 and 6, they may also be tested for 64 Kbps operation using this form.

While a channel is in loopback mode, it will be unavailable to send information to remote systems or receive information from remote systems. Incoming calls will be answered, but the calling system will be unable to establish a connection; eventually it will drop the call and attempt to call back at its next scheduled transmission time.

Also, if you put a channel in loopback mode, any active calls will be dropped. It is therefore recommended before you perform this test you check the status of the channel. It is also not a good idea to perform this test during peak traf???c times.

1. Go to the maintenance : network form. Set select test to 8 to test a 64 Kbps network

NOTE

If you have an MPDM/M1* between the AUDIX system and the PBX, you may also test channels 5 or 6 (the RS-232 channels) for 64 Kbps operation.

2.Have the serving of???ce place a call to the telephone number assigned to the channel you speci???ed on the maintenance : network form. If the test is successful, any data the serving of???ce sends over the AUDIX channel will be echoed back.

3.Go to the maintenance : network form. Set select test to 9 to take the channel out of

_______________________________________________________________________________________

_______________________________________________________________________________________

SYSTEM 85

DCP

POINT-

OF-

PRESENCE

SWITCH

. . . . . . . . . . . . . . . . . . . . . . . . .

MAINTENANCE: NETWORK FORM:

NETWORK LOOPAROUND START 56/64 Kbps

Figure 12-2. 64 Kbps Network Loop-Around Test

12-6 DCP Mode 3 Installation and Administration

________________________________________________________________________________________________

________________________________________________________________________________________________

13. AUDIX System Administration

_______________________________________________________________________________________

_______________________________________________________________________________________

Before you can administer an AUDIX system for networking, the ACC or ACCE must be installed. If not done already, install the AUDIX Communications Controller (ACC or ACCE) circuit pack and make sure it is administered using the maintenance : network and the system : translation : network port form. form. Then use this chapter to administer the AUDIX system in association with one or more other AUDIX systems for networking.

NOTE

If the network includes R1V5 and/or R1V6 and/or R1V7 systems along with R1V3 and/or R1V4 systems, the Sending Restrictions feature on any R1V5 or later system must be turned off.

REMOTE UPDATES

Each AUDIX system in a network has its own data base with information on both local subscribers and remote subscribers. The system administrator may use the remote updates feature to make certain that every AUDIX data base has the same information for all subscribers across the network. When an AUDIX system sends remote update information for a subscriber to another system, it sends the voiced name, ASCII name, extension, and (for R1V5 and later systems) the community ID.

The remote updates will only be sent for subscribers whose extension numbers fall within the extension ranges administered on the system : translation : machine : audix/amis/call delivery form. For example, AUDIX A may be administered with an address range from 3000 to 3999. If AUDIX B???s remote pro???le for AUDIX A only lists a subset of this range (such as extensions 3000 to 3100), AUDIX B will only request partial or complete updates for extensions 3000 to 3100 from AUDIX A.

Partial Updates

The AUDIX systems in the network can be administered so partial updates happen automatically. If all systems in the network are so administered, any time a subscriber pro???le is added, deleted, or modi???ed from a system in the network, that system will automatically notify all other systems in the network of the change.

13-1

13-2 AUDIX System Administration

________________________________________________________________________________________________

________________________________________________________________________________________________

Complete Updates

The system administrator can also request a complete update from remote systems at any time using the system : translation : remote updates form. An update should be requested, for example, from every remote node in the network when a new network node is added. If the system administrator wants to request a complete update, they should do so outside of prime-time hours, so voice mail deliveries are not delayed. In addition, the local AUDIX system will automatically schedule a complete update from a remote system (to be executed during non-prime time hours) if it detects a discrepancy between its data base and that of a remote system.

For R1V6 or later systems, remote updates have priority over voice mail and status messages NOTE that are to be sent over the network. For R1V5 and earlier systems, voice mail and status

messages are higher priority than remote updates.

If the updates in ???eld on the system : translation : machine : audix/amis/call delivery form for the local system is set to y, the local system will accept updated data base information from any remote AUDIX systems in the network for which the updates out ???eld is set to y. Then, any time an administrator of a remote system adds, deletes, or modi???es a subscriber pro???le, the remote system will notify the local system of the change. The local system can then update its own data base so the two systems have the same information about all subscribers.

If the updates out ???eld on the system : translation : machine : audix/amis/call delivery form for the local system is set to y, the local system will send updated data base information to remote AUDIX systems in the network for which the updates in ???eld is set to y. Then, any time the administrator of the local system adds, deletes, or modi???es a subscriber pro???le, the local system will notify all remote systems of the change. The remote systems can then update their data bases so they agree with the local system.

Network Turnaround

On R1V7 systems, the system administrator has the option of allowing the network connection to be turned around. This option is activated using the system : translation : machine : audix/amis/call delivery form; it can be administered on a system-wide or per-machine basis.

???If network connection turnaround is implemented, the local machine will call a remote machine and do the following: notify the remote system that it has updated subscriber information, request updated subscriber information from the remote system, and send voice mail and updated message status information to the remote system. Then network connection will then be turned around and the remaining events will occur: the remote system will notify the local system that it has updated subscriber information, request updated subscriber information from the local system, and send voice mail and updated message status information to the local system.

???If the network turnaround feature is not implemented, the local machine will call a remote machine and do the following: notify the remote system of its updated subscriber information, request updated subscriber information from the remote system, and send voice mail and updated message status information to the remote system. The call will then be disconnected.

_______________________________________________________________________________________

_______________________________________________________________________________________

The network turnaround feature reduces system overhead time and long-distance charges by allowing all of these events to occur with a single call rather than two calls. If cost control from a central point is not critical, greater ef???ciency can be gained by implementing the network connection turnaround feature. The connection can only be turned around once during a single call.

If the system has an ACCE board installed, you can monitor the status of the network turnaround feature using the activity ???eld on the maintenance : network form (see Chapter 14 for an illustration of this form).

SYSTEM PROFILES

To administer a network, the local machine, and each remote machine to which the local machine is connected, must have a pro???le administered on the local system. The system : translation : machine : audix/amis/call delivery form is much like the subscriber : local form, except that it is used to set up pro???les for individual AUDIX systems rather than for individual subscribers. The pro???le for the system to which the administration terminal is connected should already be set up with some default values. These values may have to be changed now that the system will be part of a network. See Setting Up the Local AUDIX System Pro???le in this chapter. Once the local pro???le is set up, a remote pro???le must be set up for each remote system in the network. See Setting Up a Remote AUDIX System Pro???le in this chapter.

NOTE

The local system is always the system to which the terminal is connected. All others are considered remote systems regardless of where they are located.

SETTING UP THE LOCAL AUDIX SYSTEM PROFILE

Enter sys trans ma au on the path line. Press RETURN . The screen should display a blank system : translation : machine : audix/amis/call delivery form. Press ENTER . The form should be ???lled in with the values already assigned to the local system. See Figure 13-1, Local AUDIX System Pro???le.

The customer or the Account Team should provide you with a copy of the Administrator???s Worksheet ???lled in with values to be entered on this form. If not, use the copy provided at the end of this chapter and ???ll in the values as you go. The following paragraphs provide guidelines for administering the local AUDIX system.

13-4 AUDIX System Administration

________________________________________________________________________________________________

________________________________________________________________________________________________

NOTE

Figure 13-1. Local AUDIX System Pro???le

Use TAB to move to the next ???eld. Use SHIFT-TAB to move to the previous ???eld. Use BACKSPACE to move back one space in a ???eld.

Use RETURN while in a ???eld to move back to the beginning of a ???eld. Overwrite all unwanted characters with the spacebar or with DEL CHAR. Use the screen-labeled HELP keys for form and ???eld information.

Form Fields

displayed in this ???eld. After you log off and log back on, this name will also be displayed in the upper left-hand corner of the AUDIX system screen.

If you change the name of the local AUDIX system and it is running R1V5 or later software, reset the ACCE: access the maintenance : network form, enter a 5, and press CHANGE or RUN . If you change the name of the local AUDIX system and it is running R1V3 or R1V4 software, restart the AUDIX system via the startup form.

???local/remote

This display-only ???eld should show l, for local system.

_______________________________________________________________________________________

_______________________________________________________________________________________

???password

Enter 5 to 10 alphanumeric characters. This password does not have to be unique. Record it on paper so that it is not forgotten ??? you will need it when administering the other systems in the network. The password will not be displayed the next time you enter the form.

If you change the password and the AUDIX system is running R1V3 or R1V4 software, run the network data audit. To run the audit, see the maintenance : audits : fp form. If the system is running R1V5 or later software, this step is not necessary.

NOTE

This machine password is not the same password as Initialization and Administration System (INADS). It is used only by remote AUDIX systems to access this local system.

???extension length

This ???eld should already be set to the correct length, the length of the switch extensions used by the local subscribers.

???voice name

This ???eld indicates the presence of a recorded machine name fragment; no assignment is required at this time. Instructions for recording names are given later in this chapter.

???voice ID

This is a display-only ???eld showing the identi???er associated with this machine???s name fragment. The identi???er is used when recording the fragment. The local AUDIX voice ID is always 0.

???default community

The default community of AUDIX system subscribers for this machine. A community contains those subscribers who are able to send voice mail messages as permitted on the system : sending restriction form. This value can be overridden for individual subscribers on the subscriber : local form.

Using this ???eld and the system : sending restriction form, you can permit subscribers to send, or prevent them from receiving, digital networking messages on a community-of-interest basis. See the AUDIX Feature Descriptions for details about the sending restrictions feature.

???network connection type

This ???eld is only used when this system calls itself for testing purposes.

This is the type of connection the AUDIX system will attempt to set up for the test call.

???Enter dcp if the system has only Digital Communications Protocol (DCP) connections to the switch.

???Enter rs232a if the system has only switched RS-232 connections to the switch. Check the option settings on the modems or data sets for synchronous or asynchronous to be sure. If they are set for synchronous, enter rs232s.

???If the system has DCP and RS-232 connections, enter dcp for now.

???data rate

This ???eld is only used when this system calls itself for testing purposes.

13-6 AUDIX System Administration

________________________________________________________________________________________________

________________________________________________________________________________________________

This is the data rate the AUDIX system will try to use for the test call. The rate entered depends on the extent of the test (that is, the facilities involved in the loop). The ???rst test will likely be a call to the switch and back to the AUDIX system. Or in the case of a direct RS-232 connection, a call out on one RS-232 channel and back in on the other.

???Enter 56000 or 64000 if the system has only DCP connections to the switch.

???Enter 64000 if the system has only direct connections to other systems.

???Enter 19200 if modems are used for switched RS-232 and the modems are set in Microcom Networking Protocol (MNP) mode (variable rate).

???Enter 9600 if modems are used for modem pooling or for switched RS-232 at a ???xed rate of 9600 bps.

???Enter 19200 (asynchronous) if 7400A or 7400B data modules are used for switched RS-232 converted to DCP mode 2.

???channel

This ???eld is only used when this system calls itself for testing purposes.

This ???eld is used to specify an RS-232 channel (5 or 6) to be used to originate the test call. Whenever both RS-232 channels are connected in the same manner (both dedicated or both switched), this ???eld can be left blank. If blank, the AUDIX system will choose one automatically.

???dial string

This ???eld is only used when this system calls itself for testing purposes.

On R1V3 and R1V4 systems, zero (0) to 30 characters can be entered. On R1V5 or later systems, zero

(0) to 65 characters can be entered. Permissible characters depend on the type of switch and/or modem through which the AUDIX system is dialing.

The following are a few examples of dial strings:

???6000 ??? where the local system uses a DCP channel to call itself. The 6000 is an extension number assigned to one of the local system network channels (RS-232 or DCP) or to a hunt group of channels.

???9+2346000 ??? where the local system uses a DCP channel to call itself by going through the central of???ce switch. The 234 is the of???ce code assigned to the local switch, and 6000 is the same as the previous example. The ??????9?????? is the central of???ce (CO) access code at the local switch. The ??????+?????? is a pause for dial tone.

???8+7896000 ??? where the local system uses a DCP channel to call itself by going through the private network switch. The ??????8?????? is the private network access code at the local switch. The 789 is the private network code for the local switch.

???ATDT 6000 ??? where the local system uses an RS-232 channel and modem to call itself on the other RS-232 channel. The attention code (ATDT) is required by the modem (Hayes dialing). The 6000 is the extension of the other RS-232 channel on this system.

???ATDT 9,2346000 ??? where the local system uses an RS-232 channel and modem to call itself on the other RS-232 channel. the same local dialing area. The ??????,?????? is a pause for a certain number of seconds. This number is de???ned in the modem manual.

???*23 ??? where the local system uses a DCP channel to call itself through a MERLIN II that is acting as the DCP interface for a non-DCP switch. This string is used to dial a network channel of the local system (port 23).

_______________________________________________________________________________________

_______________________________________________________________________________________

???(blank) ??? where the local system uses a dedicated RS-232 channel to call itself. If another type of system is called, a dial string may be required.

The type of channel used for calling out of the AUDIX system is determined by the connection type assigned earlier. The loop used to get the call back to the AUDIX system and the type of channel used once the call gets there is determined by the dial string. See Chapter 14 for details on testing the network.

The following characters, valid only in R1V5 or later systems when a TN539 or TN539B is present, have special meaning within an AUDIX system dial string. They must be enclosed within double quotation marks, for example, "x". These characters are not passed on to the switch, modem, or endpoint in a network call. They are interpreted by the TN539 or TN539B ACCE. Special characters are described below:

???"W" indicates that multiple-stage dialing is to be used and that AUDIX system should wait for another dial prompt (dial tone or equivalent message) before sending the subsequent digits or characters.

???"B" in the dial string will be replaced with a BREAK character by the AUDIX system. This allows the AUDIX system, for example, to send a BREAK to a modem.

???"CR" in a dial string will be replaced by the AUDIX system with a carriage return character.

???"LF" in a dial string will be replaced with a line feed character.

???address ranges/warnings

The pre???x is not used on the pro???le of the local AUDIX system.

The start/ end extension de???nes a block of switch extensions that can be used at the AUDIX system when assigning subscribers. Up to ten different ranges can be speci???ed to pinpoint the exact set of extension blocks used by the local system. The length of the start and end extensions must agree with extension length. Leading zeros may be required to conform to this requirement. The end extension must be equal to or greater than the start extension.

The warnings ???eld will indicate when a duplication or overlap of another range is being assigned. The system : translation : address form shows extension numbers in use.

???Duplicate Range (or full overlap) means that the range de???ned is also de???ned for another machine pro???le. In R1V3 and R1V4, up to eight duplicates may be de???ned. In R1V5 or later software, up to sixteen can be de???ned.

As an example, say that two colocated systems serve a scattering of different extensions between 2000 and 6999. Instead of trying to pin-point blocks of extensions, which may be impossible anyway, you can de???ne the address range for both systems as start: 2000, end: 6999. A location across the country might use the same extensions as the local location. The address range(s) for the system serving that location might also require duplicate ranges.

???Overlaps means that the range de???ned is a subset of another range or is overlapping another range:

???You would be assigning a subset if you tried to assign 2000-3999 when 2000-5999 already exists. The new range would be disallowed. Instead, assign a duplicate of the existing range.

13-8 AUDIX System Administration

________________________________________________________________________________________________

________________________________________________________________________________________________

???You would be assigning an overlap if you tried to assign 5000-6999 when 2000-5999 already exists. The new range would be disallowed. Instead, assign two new ranges (2000-5999 and 6000-6999).

???message transmission schedule

These ???elds are used for remote machine pro???les only.

???updates (y/n)? in _ out _

For now, leave these ???elds set to n since this will simplify testing. After testing is complete, set these ???elds to y if you want to activate the remote updates feature.

On the local AUDIX system, if the updates in ???eld on the system : translation :

machine : audix/amis/call delivery form for the remote system is set to y, the local system will accept updated data base information from that remote AUDIX system.

On the local AUDIX system, if the updates out ???eld on the system : translation :

machine : audix/amis/call delivery form for the remote system is set to y, the local system will send updated data base information to that remote AUDIX system.

The Remote Updates feature of AUDIX Networking must be active (see the system : translation : remote updates form).

If these ???elds are left n after testing, this system will not notify other systems of changes to its data base nor will it accept updated information from other systems in the network (neither partial nor complete updates will be permitted).

???network turnaround (y/n)?

Network turnaround can be administered on a system-wide or per-machine basis. To disable this feature system wide, set this ???eld to n on the local machine pro???le. To enable the feature, set this ???eld to y on the local machine pro???le and on the appropriate remote machine pro???le(s).

If the network connection turnaround feature is implemented, the local machine will call a remote machine and the following sequence of events will occur:

1.The local system will notify the remote system that it has updated subscriber information to send.

2.The local system will request updated subscriber information from the remote system (if the remote system previously noti???ed the local system that it had updates to send). The remote system will then send its updated subscriber information to the local system.

3.The local system will send voice mail to the remote system.

4.The local system will send updated message status information to the remote system.

5.The network connection will then be turned around and the remaining events will occur:

6.The remote system will notify the local system that it has updated subscriber information to send.

_______________________________________________________________________________________

_______________________________________________________________________________________

7.The remote system will request updated subscriber information from the local system (if the local system previously noti???ed the remote system that it had updates to send). The local system will then send its updated subscriber information to the remote system.

8.The remote system will send voice mail to the local system.

9.The remote system will send updated message status information to the local system.

Set this ???eld to n if you do not want to implement network turnaround. In this case, only steps 1 through 4 will occur.

NOTE

If systems in the network are not all R1V7 and the network turnaround feature is enabled, calls may be dropped after steps 1 through 4 have been completed.

???send to non-administered recipients (y/n)?

The default value is y. If this ???eld is y, when a subscriber addresses a message to a remote extension that does not map to a remote subscriber known by the local AUDIX system, the local AUDIX system will add this potential subscriber to its data base and then send the message to every remote system in the network for which the subscriber address is valid.

The AUDIX system does this in case a new subscriber has been added somewhere in the network and this remote system has not been made aware of it either through administrator communication or through remote updates. If the subscriber is found on a remote AUDIX machine, the local AUDIX system will deliver this message to the valid remote machine(s) and validate this new subscriber. If a valid remote subscriber cannot be found, the subscriber record will be deleted eventually by one of the system audits and the AUDIX system will change the status of the message from ??????undelivered?????? to ??????undeliverable?????? in the message sender???s voice mailbox.

NOTE

Any address should not map to more than one valid subscriber in the network. However, the AUDIX software does not enforce this, so it is possible for a message to be sent to more than one subscriber if an address is duplicated.

If this ???eld is n, when a subscriber addresses a message to a remote extension or name that does not map to a remote subscriber known by the local AUDIX system, the local AUDIX system will not send the message. The subscriber who is attempting to address the message will be noti???ed that the extension is invalid.

If the network administrators keep open lines of communication (or there is just one administrator for the entire network), chances are good that each system will be kept up-to-date. Therefore, the customer would want an n entered here so the local AUDIX system is not burdened with ???nding a subscriber that probably does not exist in the ???rst place. (What usually has happened is that a user has misdialed.)

13-10 AUDIX System Administration

________________________________________________________________________________________________

________________________________________________________________________________________________

NOTE

Permitting subscribers to send messages to non-administered recipients may have a signi???cant impact on the network. It may cause unnecessary calls to other systems and load up the local subscriber data base with unneeded records.

Saving Local System Data

When you have ???nished entering data in the ???elds, press CHANGE or RUN . If the system is running R1V5 or later software, any changes or additions to this form are put to use immediately. R1V3 and R1V4 require that the network data audit be run. To run the audit, see the maintenance : audits : fp form.

SETTING UP A REMOTE AUDIX SYSTEM PROFILE

Log in to the local AUDIX system using the display terminal and enter sys trans ma au on the path line. Press RETURN . A blank machine pro???le will be displayed. See Figure 13-2, Remote AUDIX System Pro???le, for a sample of what you will be entering. The customer or the Account Team should provide you with a copy of the Administrator???s Worksheet ???lled in with values to be entered on this form. If not, use the copy provided at the end of this chapter and ???ll in the values as you go. The following paragraphs provide guidelines for administering remote AUDIX systems.

Figure 13-2. Remote AUDIX System Pro???le

_______________________________________________________________________________________

_______________________________________________________________________________________

Form Fields

??? machine name

Enter the name of the remote system. Press ENTER to make sure this name is not already assigned. At

the bottom of the form you should see ??????doesn???t exist??????.

???local/remote

This is a display-only ???eld. It will display r once the remote system is administered on the local system.

???password

Enter 5 to 10 alphanumeric characters. This password does not have to be unique. Record it on paper so that it will not be forgotten. You will need it when administering the other systems in the network. It will not be displayed the next time you enter this form.

NOTE

This is not the INADS login password. This password is used only by the local AUDIX system to access this particular remote AUDIX system.

???extension length

Enter the length of the extensions used for this remote system.

???voice name

This ???eld indicates the presence of a recorded machine name fragment; no assignment is required at this time. Instructions for recording names are given later in this chapter.

???voice ID

This is a display-only ???eld showing the identi???er associated with this machine???s name fragment. The identi???er is used when recording the fragment. The remote AUDIX system voice ID is between 1 and 100.

???default community

The default community of AUDIX system subscribers for this machine. A community contains those subscribers who are able to send voice mail messages as permitted on the system : sending restriction form. This value can be overridden for individual subscribers on the subscriber : remote form.

Using this ???eld and the system : sending restriction form, you can permit subscribers to send, or prevent them from receiving, digital networking messages on a community-of-interest basis. See the AUDIX Feature Descriptions for more information about the sending restrictions feature.

13-12 AUDIX System Administration

________________________________________________________________________________________________

________________________________________________________________________________________________

???network connection type

This ???eld is used when the local AUDIX system attempts to call this remote AUDIX system for the purpose of transmitting messages and updates.

This is the type of connection the AUDIX system will attempt to set up for the connection to the remote AUDIX system.

???Enter dcp if this remote system is accessed using normal DCP channels (that is, AUDIX channels 1-4).

???Enter rs232a if this remote system is accessed using the RS-232 modems or data modules (unless these channels use synchronous modem pooling somewhere in the link; then use rs232s).

???Enter rs232s if this remote system is accessed using direct RS-232 cabling.

???data rate

This ???eld is used when the local AUDIX system attempts to call this remote AUDIX system for the purpose of transmitting messages and updates.

This is the data rate the AUDIX system will try to use for the call. The rate depends on the facilities involved in the call:

???Enter 64000 if the remote system is colocated at the same switch as the local system.

???Enter 64000 if the switch???s Data Service 1 (DS1) interface to a T1 Carrier is used to call the remote system.

???Enter 56000 if a 56 Kbps network is used.

???Enter 64000 if direct RS-232 cabling is used to a colocated system.

???Enter 19200 if modems (MNP mode) are used for switched RS-232.

???Enter 9600 if modems (???xed rate) are used for switched RS-232.

???Enter 19200 (asynchronous) if 7400A or 7400B data modules are used for RS-232 converted to switched DCP mode 2.

???Enter 9600 if modems are used for DCP mode 2 (modem pooling).

???channel

This ???eld identi???es which RS-232 channel is used when the local AUDIX system attempts to call this remote AUDIX system for the purpose of transmitting messages and updates.

If one of the RS-232 channels is connected to this remote system, enter the number (5 or 6) of the channel here. If both RS-232 channels are connected to this remote system, leave this ???eld blank.

???dial string

This ???eld is used when the local AUDIX system attempts to call this remote AUDIX system for the purpose of transmitting messages and updates. It will also be used whenever a connection test to this remote system is performed from the local system.

On R1V3 and R1V4 systems, zero (0) to 30 characters can be entered. On R1V5 or later systems, zero

(0) to 65 characters can be entered. Permissible characters depend on the type of switch and/or modem through which the AUDIX system is dialing.

The following are examples:

_______________________________________________________________________________________

_______________________________________________________________________________________

???6000 ??? where the local system uses a DCP channel to call itself. The 6000 is an extension number assigned to one of the remote system network channels (RS-232 or DCP) or to a hunt group of channels.

???9+2346000 ??? where the local system uses a DCP channel to call a remote system located at a remote switch, but in the same local dialing area. The 234 is the of???ce code assigned to the remote switch, and 6000 is the same as the previous example. The ??????9?????? is the central of???ce (CO) access code at the local switch. The ??????+?????? is a pause for dial tone.

???8+7896000 ??? where the local system uses a DCP channel to call a remote system located at a different network node. The ??????8?????? is the network access code at the local switch. The 789 is the network access code for the remote switch.

???<number>,,,,, ??? where the ???ve commas following the number the local system dials to reach the remote system are used to cause the system to pause (each comma causes a 2-second pause). Pauses are needed for correct operation in certain modems such as the Telebit T1000, which requires a 10- second pause after dialing before starting its internal timers.

???ATDT 6000 ??? where the local system uses an RS-232 channel and modem to call a colocated system. The attention code (ATDT) is required by the modem (Hayes dialing). The 6000 is the same as the previous examples.

???ATDT 9,2346000 ??? where the local system uses an RS-232 channel and modem to call a remote system located at a remote switch but in the same local dialing area. The ??????,?????? is a pause for a certain number of seconds. This number is de???ned in the modem manual.

???*23 ??? where the local system uses a DCP channel to call a MERLIN II acting as the DCP interface for a non-DCP switch. This string is used to dial a remote system that is colocated at the MERLIN II (port 23).

???(blank) ??? where the local system uses a dedicated RS-232 channel to access a colocated remote AUDIX system. If another type of system is called, a dial string may be required.

The type of channel used for calling out of the AUDIX system is determined by the connection type assigned earlier. The loop used to get the call back to the AUDIX system and the type of channel used once the call gets there is determined by the dial string. See Chapter 14 for details on testing the network.

The following characters, valid only on R1V5 or later systems when a TN539 or TN539B is present, have special meaning within an AUDIX system dial string. They must be enclosed within double quotation marks, for example, "x". These characters are not passed on to the switch, modem, or endpoint in a network call. They are interpreted by the TN539 or TN539B ACCE. Special characters are described below:

???"W" indicates that multiple-stage dialing is to be used and that AUDIX system should wait for another dial prompt (dial tone or equivalent message) before sending the subsequent digits or characters.

???"B" in the dial string will be replaced with a BREAK character by the AUDIX system. This allows the AUDIX system, for example, to send a BREAK to a modem.

???"CR" in a dial string will be replaced by the AUDIX system with a carriage return character.

???"LF" in a dial string will be replaced with a line feed character.

13-14 AUDIX System Administration

________________________________________________________________________________________________

________________________________________________________________________________________________

When ???nished entering the dial string, press ADD . This will create and save the remote

NOTE machine pro???le. Continue administering the following ???elds.

???address ranges/warnings

See the previous section (Setting Up the Local AUDIX System Pro???le) and the following for appropriate entries:

???Assign a different range for each method that will be used to address messages to subscribers. Back in Figure 13-2, Remote AUDIX System Pro???le, the following three ranges are assigned to identify subscribers at a remote AUDIX system:

???The ???rst range does not use a pre???x. The pre???x is only required when one or more of the remote subscribers share the same extension numbers as the local subscribers. The AUDIX system uses the pre???x to distinguish between local and remote subscribers in this case.

???The second range uses the public network access code as the pre???x. When addressing a message to a remote subscriber, the local subscriber enters the remote subscriber???s number as if they were placing a call to that subscriber. This may be the easiest method in some instances.

???The third range uses a location code as the pre???x. This method simpli???es addressing messages by requiring only an alphanumeric code in front of the extension number. Location codes, besides being shorter in length, are often more friendly to the user.

???The pre???x is used only by the AUDIX system to identify subscribers. It is not used for dialing out, so it does not need to match an area/of???ce code. It consists of 0 to 27 alphanumeric characters. Added with the extension, up to 32 characters can be assigned to a range.

???message transmission schedule

These ???elds are used to specify when the local AUDIX system will call this remote AUDIX system. Three cycles can be de???ned in each remote AUDIX system pro???le. Enter in military time (hh:mm), a start time, an end time, and an interval. Cycles may be assigned to minimize toll charges that might be incurred in transmitting messages to this remote system.

The interval speci???es the frequency of connections during the cycle. The total time of the cycles cannot exceed 24 hours. Cycles cannot overlap. A cycle can span across midnight. The default is one cycle from 00:00 to 23:59 at 1 hour (01:00) intervals. One hour intervals are ???ne during the installation of the network. After the network is completely set up, reset the interval to the interval furnished on the Engineering Worksheet (typically 5 minutes).

If the transmission queue reaches a threshold of 150 messages, the local system will attempt a call to this remote system every minute (regardless of the administered interval) during the administered transmission times.

???updates in/updates out

For now, leave these ???elds set to n since this will simplify testing. After testing is complete, set these ???elds to y if you want to activate the remote updates feature.

_______________________________________________________________________________________

_______________________________________________________________________________________

On the remote AUDIX system, if the updates in ???eld on the system : translation :

machine : audix/amis/call delivery form is set to y, it will accept updated data base information from the local AUDIX system (provided the local system???s updates out ???eld is set to y).

On the remote AUDIX system, if the updates out ???eld on the system : translation :

machine : audix/amis/call delivery form is set to y, it will send updated data base information to the local AUDIX system (provided the local system???s updates in ???eld is set to y).

The Remote Updates feature of AUDIX Networking must be active (see the system : translation : remote updates form).

If these ???elds are left n after testing, this remote system will not notify this local system of changes to its data base nor will this local system send update information to this particular remote system. (neither partial nor complete updates will be permitted).

NOTE

If the customer wants to use remote updates, make sure that on the system : appearance form the prime time ???eld is not set for 24 hours. If prime-time is 24 hours, automatic, complete remote updates cannot run since they are scheduled to run in non-prime hours; remote updates would only run on demand.

???network turnaround (y/n)?

Set this ???eld to y to implement network turnaround. (This ???eld must also be set to y on the local machine pro???le for network connection turnaround to work).

If network connection turnaround is implemented, the local machine will call this remote machine and the following sequence of events will occur:

1.The local system will notify this remote system that it has updated subscriber information to send.

2.The local system will request updated subscriber information from this remote system (if this remote system previously noti???ed the local system that it had updates to send). This remote system will then send its updated subscriber information to the local system.

3.The local system will send voice mail to this remote system.

4.The local system will send updated message status information to this remote system.

5.The network connection will then be turned around and the remaining events will occur:

6.The remote system will notify the local system that it has updated subscriber information to send.

7.The remote system will request updated subscriber information from the local system (if the local system previously noti???ed the remote system that it had updates to send). The local system will then send its updated subscriber information to the remote system.

8.This remote system will send voice mail to the local system.

9.This remote system will send updated message status information to the local system.

Set this ???eld to n if you do not want to implement network connection turnaround for this speci???c remote machine. In this case, only steps 1 through 4 will occur.

13-16 AUDIX System Administration

________________________________________________________________________________________________

________________________________________________________________________________________________

NOTE

If systems in the network are not all R1V7 and the network turnaround feature is enabled, calls may be dropped after steps 1 through 4 have been completed.

???send to non-administered recipients (y/n)?

The default value is y. If this ???eld is y, when a subscriber addresses a message to a remote extension that does not map to a remote subscriber known by the local AUDIX system, the local AUDIX system will add this potential subscriber to its data base and then send the message to every remote system in the network for which the subscriber address is valid.

The AUDIX system does this in case a new subscriber has been added somewhere in the network and this remote system has not been made aware of it either through administrator communication or through remote updates. If the subscriber is found on a remote AUDIX machine, the local AUDIX system will deliver this message to the valid remote machine(s) and validate this new subscriber. If a valid remote subscriber cannot be found, the subscriber record will be deleted eventually by one of the system audits and the AUDIX system will change the status of the message from ??????undelivered?????? to ??????undeliverable?????? in the message sender???s voice mailbox.

NOTE

Any address should not map to more than one valid subscriber in the network. However, the AUDIX software does not enforce this, so it is possible for a message to be sent to more than one subscriber if an address is duplicated.

If this ???eld is n, when a subscriber addresses a message to a remote extension or name that does not map to a remote subscriber known by the local AUDIX system, the local AUDIX system will not send the message. The subscriber who is attempting to address the message will be noti???ed that the extension is invalid.

If the network administrators keep open lines of communication (or there is just one administrator for the entire network), chances are good that each system will be kept up-to-date. Therefore, the customer would want an n entered here so the local AUDIX system is not burdened with ???nding a subscriber that probably does not exist in the ???rst place. (What usually has happened is that a user has misdialed.)

NOTE

Permitting subscribers to send messages to non-administered recipients may have a signi???cant impact on the network. It may cause unnecessary calls to other systems and load up the local subscriber data base with unneeded records.

Saving Remote System Data

When you are ???nished entering the data, press CHANGE or RUN . Any changes or additions to this form are put to use immediately unless the system is running R1V3 or R1V4 software; in this case, run a network data audit (see the maintenance : audits : fp form).

Exit the form and re-enter it to verify that the changes were accepted. Notice that the password is no longer displayed.

_______________________________________________________________________________________

_______________________________________________________________________________________

RECORDING AUDIX MACHINE NAMES

Voiced-in machine names can be used to identify subscribers??? local machines. When a subscriber sends a message to another subscriber, the message header will indicate from which AUDIX system the message was sent, and thus, how to return the call.

A name should be recorded for each AUDIX system in the network. Only the AUDIX administrator can perform this function (the subscriber assigned with announcement control). The AUDIX administration or maintenance terminal is required. Complete the following steps:

1.At the administration or maintenance terminal, go to the list : machine form, and press ENTER . Note the voice ID number for the current system. Make a list of /ID numbers for all

systems for which you are recording a name. The voice ID shown for a given system must be entered during the assignment of that system???s voiced name.

2.From a voice terminal, dial the AUDIX system extension. The AUDIX system will respond with:

Welcome to AUDIX. Please enter your extension and pound sign.

6.Press 6 . The AUDIX system will respond with:

Enter machine voice ID and pound sign.

7.The local AUDIX system???s ID is always 0. For a remote AUDIX system, get the ID from the list

created in step 1. Enter the ID and press # . The AUDIX system will respond with:

After recording, press 1. Record at the tone.

8. Speak the machine name and press 1 . You are then given a chance to replay, delete, and rerecord

the name. You might want to record the system???s dialing pre???x along with the name. This will give subscribers additional feedback.

When ???nished recording press * and # . The AUDIX system will respond with:

To record another machine name, enter machine voice ID.......

Repeat the sequence until a name has been recorded for each machine.

9.If you want to verify that the name has been recorded successfully, go to the system : translation : machine : audix/amis/call delivery form and display the pro???le for each system. The voice name ???eld should now be set to y. If you want to remove the machine name, set this ???eld to n.

13-18 AUDIX System Administration

________________________________________________________________________________________________

________________________________________________________________________________________________

ADMINISTERING PORTS

The system : translation: network port form only affects the local system. It is used to administer the RS-232 channels. It is also used to activate the DCP channels and to indicate the data rate that will be used when a DCP mode 2 call is received. Each DCP channel has its own rate. The default, 9600 bps, is typically used. The RS-232 channels cannot be equipped, but may be cabled up, if the system is equipped with a TN366 or TN366B. The system must have the TN539 or TN539B to equip and use the RS-232 channels.

Log in to an AUDIX administration or maintenance terminal and type sys tra net on the path line. Press RETURN . A system : translation : network port form will be displayed showing the factory default settings. The port type ???eld shows that channel 5 and channel 6 of the TN539 or TN539B are the RS-232 channels.

modem initialization strings:

channel 5: __________________________________________________________________

channel 6: __________________________________________________________________

DCP ports ??? data rate for incoming Mode 2 calls or 0 if channel is not used channel 1: _____ channel 2: _____ channel 3: _____ channel 4: _____

Figure 13-3. The Network Port Form

_______________________________________________________________________________________

_______________________________________________________________________________________

Form Fields

???equipped

For each RS-232 channel cabled, set equipped to y.

???synch/asynch

This ???eld indicates the operating mode for the channel.

???If channel 5 is cabled through a modem or data set to the switch, enter an a. If it accesses a synchronous modem pool once inside the switch, however, you should enter an s.

???If channel 5 is cabled directly to another system, enter an s.

Set the ???elds appropriately for channel 6. Assignments may be different than channel 5.

???data rates

Assign data rates for each RS-232 channel. The default value for data rate (1): is 9600. For modems

that AT&T supports, the default value for both data rate (2): and data rate (3): is null (blank).

???If the RS-232 channel is not converted to DCP the data rate administered should match the modem speed. The following values are typical:

???If channel 5 is connected through the switch, set data rate 1 to 19200. Leave data rate 2 and data rate 3 blank.

???If channel 5 is connected directly to another system, set data rate 1 to 64000. Set data rate 2 to 56000. Set data rate 3 to 19200.

???If the RS-232 channel is converted to DCP, do one of the following:

???Set data rate 1 to 56000 (synchronous) if a Modular Processor Data Module (MPDM), Model M1*, is used on channel 5 for switched RS-232 converted to DCP mode 1. Leave data rate 2 and data rate 3 blank.

???Set data rate 1 to 64000 (synchronous) if a Modular Processor Data Module (MPDM), Model M1*, is used on channel 5 for switched RS-232 converted to DCP mode 3. Leave data rate 2 and data rate 3 blank.

???Set data rate 1 to any value between 1200 and 19200 (asynchronous) if a 7400A or 7400B data module is used on channel 5 for switched RS-232 converted to DCP mode 2. Leave data rate 2 and data rate 3 blank.

Set the ???elds appropriately for channel 6.

???switched/dedicated

RS-232 channels converted to DCP mode 1 or DCP mode 3 via an MPDM/M1* must be administered as dedicated since these channels can only be used for incoming calls; they cannot be used for outgoing calls.

???Enter s when the channel is connected to the switch through a modem or a 7400A or 7400B data module.

???Enter d when the channel is connected directly to another system or if the channel is converted to DCP mode 1 or DCP mode 3 via a MPDM/M1*, data module.

13-20 AUDIX System Administration

________________________________________________________________________________________________

________________________________________________________________________________________________

???modem initialization string

The modem initialization string is the character string that the TN539 or TN539B sends to initialize the modem connected to the corresponding RS-232 port. You can enter up to 65 printable ASCII characters; however, not all modems will accept that many. Most modems do not distinguish between upper- and lower-case letters, so you may enter them either way. If you are using an AT&T supported modem, you can get the appropriate dial string from the modem initialization string on the system : translation : network port form. If you are using modems other than the ones speci???ed in this document, check the documentation shipped with the modem to determine the appropriate dial string and the number of characters allowed in the string. Usually, the ??????at?????? at the beginning of the string and spaces in the string are not counted as part of the string.

???If the RS-232 channels are cabled directly to another system, leave this ???eld blank.

???If the RS-232 channels are cabled to the switch through an MPDM/M1*, leave this ???eld blank.

???If the RS-232 channels are cabled to the switch through a 7400A or 7400B, enter:

at &c1 &r1 &d2 &s0 s0=1 &w

???If the RS-232 channels are cabled to the switch through an AT&T Paradyne DM424 (or DL424), enter one of the following. The same string should be used for the modem at the called system:

???for MNP 19.2 Kbps mode, enter:

at&f *f3 *e3 s0=1 s2=128 m0 &w

???for non-MNP mode, ???xed at 9600 bps, enter: at&f *f3 s0=1 s2=128 m0 *e0 *s1 &w

???If AT&T 2296A modems are used, enter one of the following:

???for MNP 19.2 Kbps, enter:

at&f &d2 &c1 s0=1 m0 \n3 \j0 \q2 \g1 \a2 \v1 \t2 &w

Do not use MNP with a 2296 unless it is calling another 2296.

???for non-MNP mode ???xed at 9600 bps, enter: at&f &s0 &d2 &c1 s0=1 m0 s2=128 &w

???If a MICROCOM QX 3296/C modem is used, enter one of the following. The same string should be used for the modem at the called system. Enter the string exactly as shown. It already approaches the maximum number of characters allowed by this modem (40 characters; spaces shown are not included in the 40 characters):

???for MNP 19.2 Kbps mode, enter:

at&f&d2&c1s0=1m0s2=128 \n3 \j0 \q2 \g0 \a2 %l0&w

(The character after the ??????%?????? is the letter ??????l??????.

???for non-MNP mode, ???xed at 9600 bps, enter:

at&f &s0 &d2 &c1 s0=2 m0 %l0 \x1 \j0 s2=128 &w

The character after the ??????%?????? is the letter ??????l??????.

_______________________________________________________________________________________

_______________________________________________________________________________________

???For an AT&T Paradyne model 3820 modem connected to the RS-232 ports (not in a modem pool), enter the following for 9600 bps asynchronous operation. The same string should be used for the modem at the called system:

at&f0 &d2 m0 \n1 \q3 s0=1 s2=128 s76=1 s78=1 s41=3 &w0

???A Telebit T1000 stand-alone modem may be connected to the RS-232 ports (not in a modem pool). When the modem is ???rst installed, power it up, open the front panel, and push the RESET button. This puts the modem in conventional mode. You can then enter the following dial string for 9600 bps asynchronous operation. The same string should be used for the modem at the called system:

at &fm0 &d2 &c1 &k3 s0=1 s2=128 &w0 &y0

For T1000 modems only, the System 75, Generic 1, or Generic 3 analog stations form must have the distinctive audible alert ???eld set to n.

NOTE

Telebit modems can only make or receive calls from another Telebit modem (such as another T1000). This modem is only certi???ed to work on RS-232 ports 5 and 6.

???modem initialization status

This display-only ???eld should be blank. If it is not blank, it is displaying the status of a previous initialization and it will be updated when you save your data.

???DCP ports ??? data rate for incoming mode 2 calls or 0 if channel not used

This ???eld does not apply for systems with the TN366 or TN366B. For systems with the TN539 or TN539B, this ???eld indicates the data rate that the TN539 or TN539B will specify in response to a "data options query" from the switch for an incoming DCP Mode 2 call (a call that uses modem pooling to access this remote system). Permissible values are 0, 1200, 2400, 4800, 9600, and 19200. If the DCP channels are not to be used, enter 0 in each ???eld. For System 75, Generic 1, or Generic 3, enter 0 for channel 2 and channel 4.

If the AUDIX system is using a 7400A or 7400B to talk with another AUDIX system that also uses a 7400A/B, the incoming DCP mode 2 data speed should match the speed set on the 7400A/B.

If the AUDIX system is receiving mode 2 calls from other AUDIX systems as well, and these systems use speeds different from the 7400A/B, multiple speeds can be entered on the form. Contact the BCSDC for information on using multiple speeds.

Saving Data

After you have completed this form, press CHANGE or RUN to save any changes or additions.

If initialization strings were entered, the AUDIX system will now send these strings to the modems to initialize them. The modem initialization status ???elds show ??????pending??????. After a few seconds, press

ENTER to display the status of this new initialization attempt. If ??????pending?????? is still displayed, repeat the wait-and-press ENTER procedure until some result is displayed. When a result is displayed, press SHIFT and TAB at the same time to get to the modem initialization status ???elds. Then press f5 (???eld help) for an explanation of the result.

13-22 AUDIX System Administration

________________________________________________________________________________________________

________________________________________________________________________________________________

ADMINISTERING SYSTEM LIMITS

Access the traffic : feature : day form by typing tr f d on the path line. Press RETURN .

Record the number displayed in the subscribers : local ???eld. You might add to this number the number of local subscribers the customer expects to add over the next 12 months; record the total. Also record the expected total of remote subscribers in the network (subscribers that reside somewhere in the network other than on the local system).

Next, access the system : limits form by typing sy li on the path line. Press RETURN . Administer the following ???elds.

Form Fields

???subscribers, local

Set this ???eld to the number (or expected number) of local subscribers, up to a maximum of 4000 (see Figure 13-4, The System Limits Form).

???administered remote

Enter the number of administered and nonadministered remote subscribers that are expected to be included in the entire network, up to a maximum of 28,000. Do not put in a larger number than necessary.

NOTE

If the send to non-administered recipients ???eld on the system :

translation : machine : audix/amis/call delivery form is set to y, setting the administered remote ???eld to 28,000 will not leave room for non- administered (unknown) subscribers to be added.

This ???eld is used for two purposes:

???To calculate the system data (sdat) ???lesystem size requirements for all remote subscribers (both administered and nonadministered)

???To calculate recommended ???lesystem size requirements for the other ???lesystems on the form for only the administered remote subscribers

Because of this dual purpose, the system : limits form should be used in two steps, as described in the next section.

Calculating Filesystem Sizes

To calculate ???lesystem space requirements for all remote AUDIX subscribers (both administered and nonadministered), use the following procedure:

1.Move the cursor to the subscribers, local ???eld and type the total number of administered local subscribers (for example, 2000).

_______________________________________________________________________________________

_______________________________________________________________________________________

2. Move the cursor to the subscribers, administered remote ???eld and type the total number of administered and nonadministered remote subscribers (for example, 6000). Press F1 (CHANGE or RUN).

NOTE

AUDIX digital networks typically have a larger number of administered remote subscribers because the remote updates feature adds remote subscribers automatically. However, AMIS analog networks typically have a larger number of nonadministered remote subscribers because subscribers are less likely to be manually administered at each AMIS analog networking site.

3.Record the value displayed for the system data ???lesystem. This recommended ???lesystem size should accommodate all remote subscribers in the network (both administered and nonadministered).

4.Return to the subscribers, administered remote ???eld and type the number of

administered remote subscribers (for example, 4000). Press F1 (CHANGE or RUN).

5.The ???elds at the bottom of the screen indicate the recommended ???lesystem sizes for this system based on the limits you just entered. Record the recommended values for all the ???lesystems except the system data ???lesystem (which you calculated previously).

NOTE

If you have an AUDIX digital networking setup that shares voiced-in names among machines, increase the size of the names ???lesystem by 10 percent above the ???gure shown on this form.

messages, total in all mailboxes: ______ awaiting delivery: ______

RECOMMENDED FILESYSTEM SIZES (IN BLOCKS), BASED ON LIMITS

Figure 13-4. The System Limits Form

13-24 AUDIX System Administration

________________________________________________________________________________________________

________________________________________________________________________________________________

Comparing the Recommended File Sizes to Actual Sizes

Compare the ???lesystem sizes recorded in the previous section with the actual sizes. The ???lesystem sizes can be displayed using the filesystem : list form. The recommended values project worst-case situations, so if the actual sizes of these ???lesystems are close, it is probably not necessary to change them now. You should monitor ???lesystem use on an ongoing basis (see the AUDIX Administration document). They can be changed later if necessary.

Increasing the Size of a Filesystem

If a ???lesystem needs to be increased, the AUDIX system must be shut down. Go to the shutdown form and do a camp-on administrative shutdown.

To increase the size of a ???lesystem, go to the filesystem : detail form. Set ???lesystem to the name of the ???lesystem to be increased (for example, disk00.ss). Press TAB . Set type to the type of the ???lesystem. Press ENTER .

Tab to size and overwrite the current size with the new recommended size. Press CHANGE or RUN .

If there is not enough free space on the disk to allow the change, look on another hard disk (disk00 to disk06) for available space. If there is available space on another disk, do a physical copy of the ???lesystem from the original disk to the new disk (filesystem : copy form). Delete the original ???lesystem from the original disk and increase the size of the new ???lesystem to its recommended value.

If you cannot ???nd available space on any of the other hard disks, call the Technical Service Center (TSC) and ask them to determine if any ???lesystems can be decreased in size (some ???lesystems may be largely free space). Once this is done, you should be able to increase the size of the original ???lesystem.

If the ???lesystem is redundant, there must be space on both the primary and backup disk.

NOTE

_______________________________________________________________________________________

_______________________________________________________________________________________

MOVING A SUBSCRIBER BETWEEN AUDIX SYSTEMS IN A

NETWORK

At some time, you may need to move a subscriber (or a group of subscribers) from one AUDIX system to another in an AUDIX network. The recommended way to move a subscriber(s) from AUDIX system 1 to system 2 is shown below.

Make sure the remote update ???elds on the system : translation : machine :

audix/amis/call delivery and system : translation : remote updates forms are set to y for the entire network.

1. Remove the subscriber(s) from system 1 using the subscriber : local form and the DELETE key.

2.Run the mailing lists audit using the maintenance : audits : fp form on the local and remote systems. These audits will delete references to the removed subscriber(s) from any mailing lists on system 1. Then run the subscriber data audit. This audit will prevent errors or redundancy in the subscriber data. This reduces the chances of introducing problems into the network.

3.Do one of the following:

???Run a connection test using the maintenance : network form. One at a time, connect to all systems in the network. This test will notify the other systems of an update pending.

Now at each of the other systems, run a connect test to system 1. The subscribers removed from system 1 should now be deleted as remote subscribers at the other systems.

???If the network is not heavily loaded with voice mail between systems and the transmission intervals of the systems are set to 5 or 10 minutes, you can just wait for 30 minutes or so to make sure each system has had a chance to call all other systems.

4.Log in to system 2. Check the subscriber : remote form to verify that the removed subscriber(s) do not exist on this system. If the subscriber(s) still exist, remove them manually with

the DELETE key. If you are moving a range of subscribers, you will want to remove their range of extension numbers from system 1???s pro???le. Do this at system 1 (local machine pro???le) and at system 2 (remote machine pro???le).

NOTE

You will also want to remove the range from the other systems, but do not remove the range until you verify that the other systems no longer reference the removed subscribers.

If any of the moved subscribers were included on mailing lists, they will need to be re- administered on those mailing lists.

Now you are ready to add the subscriber(s) to system 2.

1.Check the pro???le for system 2 (local machine pro???le). If the subscriber extension(s) is not part of one of the de???ned ranges, alter one of the ranges or add a new one. Be careful not to create an overlap of another range.

2.Repeat step 1 at all other systems on system 2???s pro???le (a remote pro???le for the other systems). This includes system 1.

13-26 AUDIX System Administration

________________________________________________________________________________________________

________________________________________________________________________________________________

3.Log back on to system 2 using an administration or maintenance terminal and add the subscriber(s) using the subscriber : local form.

4.From a voice terminal, log in to system 2 using the administrator???s login. Go to voicing in the name and record the subscriber???s name.

If the name-record-by-subscribers feature is used, names will not be recorded until the ???rst time subscribers log in to the AUDIX system.

5.Run a connection test from system 2 to all other systems and from all other systems to system 2. (Or wait for the transmission intervals.)

6.Log in to system 1 using an administration or maintenance terminal. Look at the subscriber : remote form to see that the subscriber(s) is now listed as a remote subscriber(s). If the subscriber(s) is not listed, check the system : log form for ??????a full update has been requested??????. If this is the case, you must do a full update from system 1 to system 2 using the system : translation : remote updates form.

7.Repeat step 6 for the other systems remote to system 2.

_______________________________________________________________________________________

_______________________________________________________________________________________

ADMINISTRATOR???S WORKSHEET

On this page and the following page are worksheets that will help the AUDIX Network Administrator keep track of the network. The ???rst table is a sample. Make copies of the second table and keep it as a master.

Table 13-1. Sample Administrator Worksheet for AUDIX Networking

13-28 AUDIX System Administration

________________________________________________________________________________________________

________________________________________________________________________________________________

Table 13-2. Blank Administrator Worksheet for AUDIX Networking

14. AUDIX Network Testing

_______________________________________________________________________________________

_______________________________________________________________________________________

If you have just installed a network, go to the section of this chapter entitled Testing the Network Connections. If you are troubleshooting a network, go to Checking Administration Log Entries and

Troubleshooting the Network. Figures 14-1, 14-2, 14-3, and 14-4 show the maintenance : network form for various AUDIX software releases. This is the form you will use for network tests. Keep the following in mind when you perform network tests:

???There are six types of tests:

???Channel Internal Loop-Around Test ??? This test checks a single channel on the networking board. The test is local to the system being tested (Test 2).

???Modem Loop-Around Test ??? This test checks a single RS-232 channel and the modem connected to it, if so equipped. This test would not be used for RS-232 channels. The test is local to the system being tested (Test 6 ??? R1V5 or later RS-232 only).

???Network Loop-Around Start 56/64 Kbps Test ??? This test checks the transmission path from a 56 robbed-bit or 64 Kbps service of???ce (SO) facility to the local AUDIX system. The test can be conducted for any of the six AUDIX channels. To conduct the test for channels 5 or 6 (RS-232 channels) you need an MPDM/M1* between the AUDIX system and the PBX.

???Remote Connection Test ??? This test checks the transmission path from one system to another (Test 1; machine name = a remote system machine name; dialing string is ???xed). The dial string is set on the system : translation : machine : audix/amis/call delivery. Modem initialization strings are set on the system : translation : network port form.

???Near End Connection Test ??? This is a loop-around test; the local system calls itself [Test 1; machine name = the local system machine name and dial string is the network access code of the AUDIX Communications Controller (ACC) board]. When modem pooling is used in the network, the local modem pool is included in this test.

???Local Connection Test ??? This is a loop-around test; the local system calls itself [Test 1; machine name = the local system machine name and dial string is the extension number of the ACC board]. This test does not include modem pool facilities.

???The tests and, more speci???cally, the troubleshooting procedures, involve checking modem or data module settings, cabling, switch translations, and AUDIX system translations.

???AUDIX R1V3, R1V4, and R1V5 software limit the number of simultaneously active channels to four. To use all six channels simultaneously, an AUDIX system must have R1V6 or later software and a TN539 vintage 7 or TN539B ACCE.

???System 75, Generic 1, and Generic 3 only use channels 1 and 3 regardless of the AUDIX software used. The MERLIN II only uses channels 2 and 4. Do not try to use these channels for any tests.

This chapter also provides procedures for testing the Remote Updates feature and for testing voice mail between systems.

14-1

14-2 AUDIX Network Testing

________________________________________________________________________________________________

________________________________________________________________________________________________

1.connection test (machine name)

2.channel internal looparound test (channel)

3.channel busyout (channel)

4.channel enable (channel)

5.board reset

Figure 14-1. The Maintenance Network Form (R1V3 and R1V4)

1.connection test (machine name required)

2.channel internal looparound test (channel number required)

3.channel busyout (channel number required)

4.channel enable (channel number required)

5.board reset

6.modem looparound (channel number required)

Figure 14-2. The Maintenance Network Form (R1V5)

_______________________________________________________________________________________

_______________________________________________________________________________________

1.connection test (machine name required)

2.channel internal looparound test (channel number required)

3.channel busyout (channel number required)

4.channel enable (channel number required)

5.board reset

6.modem looparound (channel number required)

Figure 14-3. The Maintenance Network Form (R1V6)

1.connection test (machine name required)

2.channel internal looparound test (channel number required)

3.channel busyout (channel number required)

4.channel enable (channel number required)

5.board reset

6.modem looparound (channel number required)

7.network looparound start, 56 Kbps (channel number required)

8.network looparound start, 64 Kbps (channel number required)

9.network looparound stop (channel number required)

Figure 14-4. The Maintenance Network Form (R1V7)

14-4 AUDIX Network Testing

________________________________________________________________________________________________

________________________________________________________________________________________________

TESTING THE NETWORK CONNECTIONS

Once the network cabling and translations have been established between the local AUDIX system and one of the remote AUDIX systems, you are ready for the following:

1.Perform a connection test from the local system to the remote system (remote connection test). Remember that a remote system is any system in the network other than the system being tested. Even though a colocated system is not normally thought of as a remote system, to the local system it is.

2.If the remote connection test fails, perform the appropriate loop-around connect test (near-end connection test, local connection test, or 56/64 Kbps network loop-around test). The loop-around tests should be performed from the local system and, if nothing is found, performed from the remote system as well.

3.If the remote connection test and the loop-around test both fail, perform the internal channel and/or modem loop-around tests, as appropriate.

If at any time you get a ??????failed?????? response to a test, check the system : log form for possible reasons for the failure.

Step 1: Performing Remote Connection Tests

If you want to perform a test of the transmission path from the local system to a remote AUDIX system, select the appropriate remote connection test:

???Remote DCP connection test

???Remote switched RS-232 connection test

???Remote switched RS-232 converted to DCP connection test

???Remote dedicated RS-232 connection test

Step 1A: Testing Remote DCP Connections

This test involves a path similar to Figure 14-5, Remote Connection Test (Digital Path to Another AUDIX system) (DCP Mode 1 or 3) or Figure 14-6, Remote Connection Test (Analog Path to Another AUDIX system) (DCP Mode 2 ??? modem pooling). In the case of a colocated network, the path looks like Figure 14-7, Remote Connection Test (Colocated AUDIX system) (DCP Mode 3).

NOTE

Connection and modem loop-around tests are not supported on RS-232 ports that are converted to DCP mode 1 or DCP mode 3 using MPDM/M1* data modules. This is because the MPDM/M1* data modules do not support outdialing for these con???gurations. Use the DCP ports to test the connection to the remote system for these con???gurations.

1.Log in to the local system using the AUDIX system administration or maintenance terminal.

2.Go to maintenance : network form.

_______________________________________________________________________________________

_______________________________________________________________________________________

3.Set select test to 1.

4.Set machine name to the name of the remote system.

5. Press CHANGE or RUN . Wait for the result. If the test is not successful, check the reason printed on the screen and/or system : log and/or go to Flowcharts For Troubleshooting the Network.

SYSTEM : TRANSLATION :

MACHINE : AUDIX FORM:

MACHINE NAME AUDIX2

DIAL STRING 9+9867000

MAINTENANCE : NETWORK FORM:

CONNECT TO AUDIX2

NOTE:

Dotted facilities imply that they are not used for this particular call

Figure 14-5. Remote Connection Test (Digital Path to Another AUDIX system)

14-6 AUDIX Network Testing

________________________________________________________________________________________________

________________________________________________________________________________________________

SYSTEM : TRANSLATION :

MACHINE : AUDIX FORM:

MACHINE NAME AUDIX2

DIAL STRING 9+5387000

MAINTENANCE : NETWORK FORM:

CONNECT TO AUDIX2

NOTE:

Dotted facilities imply that they are not used for this particular call

Figure 14-6. Remote Connection Test (Analog Path to Another AUDIX system)

_______________________________________________________________________________________

_______________________________________________________________________________________

SYSTEM : TRANSLATION :

MACHINE : AUDIX FORM:

MACHINE NAME AUDIX2

DIAL STRING 7000

MAINTENANCE : NETWORK FORM:

CONNECT TO AUDIX2

NOTE:

This ???gure shows the TN539 (ACCE) in use, although not required for

this particualr network

Figure 14-7. Remote Connection Test (Colocated AUDIX system)

14-8 AUDIX Network Testing

________________________________________________________________________________________________

________________________________________________________________________________________________

Step 1B: Testing Remote Switched RS-232 Connections

This test involves a path similar to Figure 14-8, Remote Connection Test (RS-232 to Tip/Ring), or Figure 14-9, Remote Connection Test (RS-232 Colocated AUDIX system).

NOTE

Connection and modem loop-around tests are not supported on RS-232 ports that are converted to DCP mode 1 or DCP mode 3 using MPDM/M1* data modules. This is because the MPDM/M1* data modules do not support outdialing for these con???gurations. Use the DCP ports to test the connection to the remote system for these con???gurations.

1.Go to the system : translation : machine : audix/amis/call delivery form. Set machine name to the name of the AUDIX system to be called using the RS-232 channels. Press ENTER . The other AUDIX system???s machine pro???le should be displayed. If it is not displayed, it

has not been assigned. Go to Chapter 13, AUDIX System Administration, and create the remote system pro???le.

2.The network data phone number (or dial string) must contain ATDT (the modem attention code), the central of???ce (CO) access code, a comma as a pause, and the Direct Inward Dialing (DID) number associated with that AUDIX system???s network hunt group.

3.Go to the system : translation : network port form. Make sure a valid modem initialization string is assigned for the channel you want to test. See Chapter 13 if you are unsure as to what should be assigned.

4.Go to the maintenance : network form. Make sure the channel you want to test is idle. In most cases either RS-232 channel can be used for this test. If a particular channel must be used and it is not idle, wait a few minutes until it is idle.

5.Go to select test and enter 1.

6. Go to machine name and enter the name of the other AUDIX system. Press CHANGE or RUN . Wait for the result. If the test is not successful, check the system : log and/or go to Flowcharts For Troubleshooting the Network.

_______________________________________________________________________________________

_______________________________________________________________________________________

SYSTEM : TRANSLATION :

MACHINE : AUDIX FORM:

MACHINE NAME AUDIX2

DIAL STRING ATDT 9+4527000

MAINTENANCE : NETWORK FORM:

CONNECT TO AUDIX2

Figure 14-8. Remote Connection Test (RS-232 to Tip/Ring)

14-10 AUDIX Network Testing

________________________________________________________________________________________________

________________________________________________________________________________________________

SYSTEM : TRANSLATION :

MACHINE : AUDIX FORM:

MACHINE NAME AUDIX2

DIAL STRING (BLANK)

MAINTENANCE : NETWORK FORM:

CONNECT TO AUDIX 2

Figure 14-9. Remote Connection Test (RS-232 Colocated AUDIX system)

CHANGE or RUN

_______________________________________________________________________________________

_______________________________________________________________________________________

Step 1C: Testing Remote Switched RS-232 Converted to DCP Connections

This test involves a path similar to Figure 14-10, Remote Connection Test (RS-232 Converted to DCP).

1. Go to the system : translation : machine : audix/amis/call delivery form. Set machine name to the name of the remote AUDIX system. Press ENTER . The remote AUDIX system???s machine pro???le should be displayed. If it is not displayed, it has not been assigned. Go to Chapter 13, AUDIX System Administration, and create the remote system pro???le.

2.The network connection channel (or channel) should be blank unless channel 5 or channel 6 must be used for the call (in which case, enter the channel number).

3. The network data phone number (or dial string) should be blank. Press CHANGE or RUN if any changes were made.

4. Go to the system : translation : network port form. Make sure the switched/dedicated ???eld for the channel(s) is set to s. Press if any changes were made.

5.Go to the maintenance : network form. Make sure the channel to be tested is idle.

6.Go to select test and enter 1.

7. Go to machine name and enter the name of the remote AUDIX system. Press CHANGE or RUN . Wait for the result. If the test is not successful, check the system : log and/or go to Flowcharts For Troubleshooting the Network.

14-12 AUDIX Network Testing

________________________________________________________________________________________________

________________________________________________________________________________________________

SYSTEM : TRANSLATION :

MACHINE : AUDIX FORM:

MACHINE NAME AUDIX2

DIAL STRING 9+4527000

MAINTENANCE : NETWORK FORM:

CONNECT TO AUDIX2

NOTE:

For low speed,

a data module used for outgoing calls must be a 7400A/B module. 7400A/B and MPDMs can be used for low speed incoming calls.

For high speed, an MPDM/M1* is required, (incoming only ??? no outgoing calls supported).

Figure 14-10. Remote Connection Test (RS-232 Converted to DCP)

_______________________________________________________________________________________

_______________________________________________________________________________________

Step 1D: Testing Remote Dedicated RS-232 Connections

This test involves a path similar to Figure 14-11, Remote Connection Test (RS-232 Direct).

1. Go to the system : translation : machine : audix/amis/call delivery form. Set machine name to the name of the other AUDIX system. Press ENTER . The other AUDIX system???s machine pro???le should be displayed. If it is not displayed, it has not been assigned. Go to Chapter 13, AUDIX System Administration, and create the remote system pro???le.

2.The network connection channel (or channel) should be set to the number of the channel that is cabled to the other AUDIX system. In Figure 14-11, the AUDIX system 1 RS-232 channel 5 is a switched connection and channel 6 is cabled to AUDIX system 2. The AUDIX system 2 pro???le at AUDIX system 1 should have a 6 in the network connection channel ???eld.

3. The network data phone number (or dial string) should be blank. Press CHANGE or RUN if any changes were made.

4.Go to the maintenance : network form. Make sure the channel to be tested is idle.

5.Go to select test and enter 1.

6. Go to machine name and enter the name of the other AUDIX system. Press CHANGE or RUN . Wait for the result. If the test is not successful, check the system : log and/or go to Flowcharts For Troubleshooting the Network.

14-14 AUDIX Network Testing

________________________________________________________________________________________________

________________________________________________________________________________________________

SYSTEM : TRANSLATION :

MACHINE : AUDIX FORM:

MACHINE NAME AUDIX2

DIAL STRING (BLANK)

MAINTENANCE : NETWORK FORM:

CONNECT TO AUDIX2

Figure 14-11. Remote Connection Test (RS-232 Direct)

_______________________________________________________________________________________

_______________________________________________________________________________________

Step 2: Performing Loop-Around Tests

If the appropriate test in Step 1 fails, perform the appropriate loop-around test:

???Near-end connection test

???Local connection test

???Network loop-around 56 Kbps

???Network loop-around 64 Kbps

Step 2A: Testing the Near-End Connection

This tests the loop shown in Figure 14-12, Near End Connection Test (CO DCP Digital Loop-Around), the loop shown in Figure 14-13, Near End Connection Test (CO DCP Analog Loop-Around), or the loop shown in Figure 14-14, Near End Connection Test (CO RS-232 Analog Loop-Around).

2.The network data phone number (or dial string) must be the CO or network access code, a pause, and the DID number associated with the local network hunt group.

a.Use a plus sign as a pause if testing DCP channels.

b.Use a comma as a pause if testing RS-232 channels. And make sure the dial string starts with the attention code (ATDT).

3.If a change was required, press CHANGE or RUN , exit the form and go to the maintenance : audits : fp form. Run a network data audit. This is necessary for R1V3 and R1V4 systems only; it is not necessary for R1V5 and later systems.

4.Go to the maintenance : network form.

Set select test to 1. Set machine name to the name of the local AUDIX system. Press

CHANGE or RUN . Wait for the result. If the test is not successful, check the system : log and/or go to Flowcharts For Troubleshooting the Network.

14-16 AUDIX Network Testing

________________________________________________________________________________________________

________________________________________________________________________________________________

SYSTEM : TRANSLATION :

MACHINE : AUDIX FORM:

NETWORK

SWITCH

. . . . . . . . . . . . . . . . . . . . . . . . .

MACHINE NAME AUDIX1

DIAL STRING 9+4526000

MAINTENANCE : NETWORK FORM:

CONNECT TO AUDIX1

NOTE:

Dotted facilities implies that they are not used for this particular call

Figure 14-12. Near End Connection Test (CO DCP Digital Loop-Around)

_______________________________________________________________________________________

_______________________________________________________________________________________

SYSTEM : TRANSLATION :

MACHINE : AUDIX FORM:

MACHINE NAME AUDIX1 DIAL STRING 9+4526000

MAINTENANCE : NETWORK FORM:

CONNECT TO AUDIX1

. . . . . . . . . . . . . . . . . . . . . . .

Figure 14-13. Near End Connection Test (CO DCP Analog Loop-Around)

Note that in Figure 14-13 for a DCP to analog loop, the modem pool modem and data set will be included in the test (two modem-data set pairs are required).

14-18 AUDIX Network Testing

________________________________________________________________________________________________

________________________________________________________________________________________________

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

Figure 14-14. Near End Connection Test (CO RS-232 Analog Loop-Around)

_______________________________________________________________________________________

_______________________________________________________________________________________

Step 2B: Testing the Local Connection

This tests the loop shown in Figure 14-15, Local Connection Test (DCP), Figure 14-16, Local Connection Test (Switched RS-232), or Figure 14-17, Local Connection Test (Dedicated RS-232). In the case of RS-232 direct, you must ???rst arrange the cabling as shown in the ???gure.

1. Go to the system : translation : machine : audix/amis/call delivery form and press ENTER . The local machine pro???le should be displayed.

2.Make sure the network data phone number (or dial string) includes only the extension number assigned to the networking hunt group. If using switched RS-232 channels with modems, the string must still start with ATDT. If using direct RS-232 channels, the dial string should be blank.

14-20 AUDIX Network Testing

________________________________________________________________________________________________

________________________________________________________________________________________________

SYSTEM 85

OFFICE

CODE 452

EXTENSION

6000

NETWORK . . . . . . . . . . .

SWITCH

NETWORK

SWITCH

DCP

ACC

AUDIX 1

These channels are not necessarily the channels used for the test call

. . . . . . . . . . . . . . . . . . . . . . . . .

SYSTEM : TRANSLATION :

MACHINE : AUDIX FORM:

MACHINE NAME AUDIX1

DIAL STRING 6000

MAINTENANCE : NETWORK FORM:

CONNECT TO AUDIX1

Figure 14-15. Local Connection Test (DCP)

_______________________________________________________________________________________

_______________________________________________________________________________________

SYSTEM : TRANSLATION :

MACHINE : AUDIX FORM:

MACHINE NAME AUDIX1

DIAL STRING ATDT 6000

MAINTENANCE : NETWORK FORM:

CONNECT TO AUDIX1

Figure 14-16. Local Connection Test (Switched RS-232)

14-22 AUDIX Network Testing

________________________________________________________________________________________________

________________________________________________________________________________________________

SYSTEM : TRANSLATION :

MACHINE : AUDIX FORM:

MACHINE NAME AUDIX1

DIAL STRING (BLANK)

MAINTENANCE : NETWORK FORM:

CONNECT TO AUDIX1

Figure 14-17. Local Connection Test (Dedicated RS-232)

_______________________________________________________________________________________

_______________________________________________________________________________________

Step 2C: Testing the 56/64 Kbps Network Connection

This tests the connection between the local AUDIX system and a 56 Kbps or 64 Kbps serving of???ce (SO), as shown in Figure 14-18, 56/64 Kbps Network Loop-Around Test.

While a channel is in loopback mode, it will be unavailable to send information to remote systems or receive information from remote systems. Also, if you put a channel in loopback mode, any active calls will be dropped. It is therefore recommended that before you perform this test you check the status of the channel. It is also not a good idea to perform this test during peak traf???c times.

1. Go to the maintenance : network form. Set select test to 7 for to test a 56 Kbps network

NOTE

To test channel 5 or 6 (RS-232 channels) you need an MPDM/M1* between the AUDIX system and the PBX.

2.Have the serving of???ce place a call to the telephone number assigned to the channel you speci???ed on the maintenance : network form. If the test is successful, any data the serving of???ce sends over the AUDIX channel will be echoed back.

3.Go to the maintenance : network form. Set select test to 9 to take the channel out of

14-24 AUDIX Network Testing

________________________________________________________________________________________________

________________________________________________________________________________________________

SYSTEM 85

DCP

POINT-

OF-

PRESENCE

SWITCH

. . . . . . . . . . . . . . . . . . . . . . . . .

MAINTENANCE: NETWORK FORM:

NETWORK LOOPAROUND START 56/64 Kbps

Figure 14-18. 56/64 Kbps Network Loop-Around Test

_______________________________________________________________________________________

_______________________________________________________________________________________

Step 3: Performing Channel or Modem Loop-Around Tests

If the appropriate tests in step one and step two fail, perform the appropriate test:

???Channel internal loop-around test

???Modem loop-around test

Step 3A: Channel Internal Loop-Around Test

This test is used to verify the operation of an individual channel on the ACC or ACCE board. No connection (that is, no call) is needed for this test.

1.Go to the maintenance : network form.

2.Set select test to 2.

3. Go to channel and enter 1, 2, 3, or 4. Press CHANGE or RUN . Wait for the result. If the test is not successful, check the system : log and/or go to Flowcharts For Troubleshooting the Network.

Use the modem loop-around test (test 6) for channel 5 or 6.

NOTE

Step 3B: Modem Loop-Around Test

This test is only for modems connected to the RS-232 channels (that is, channel 5 or channel 6). It will test the loop to the modem and back. No action is required at the modem for this test.

1.If you are not using a MICROCOM QX 3296/C modem, go to step 2. If you are testing a MICROCOM QX 3296/C modem, you must ???rst go to the system : translation : network port form. Record the three data rate ???elds and the modem initialization string ???eld for the channel to be tested. These values will be restored once the test is completed. Now change the data rate ???elds to 2400 and change the modem initialization string ???eld to AT\n0. Press

CHANGE or RUN .

2. Go to the maintenance : network form. Set select test to 6. Set channel to 5 or 6. Press

CHANGE or RUN . Wait for the result. If the test is not successful, check the system : log and/or

go to Flowcharts For Troubleshooting the Network.

3.If you are testing a 3296/C, go back to the system : translation : network port and restore the original translations.

14-26 AUDIX Network Testing

________________________________________________________________________________________________

________________________________________________________________________________________________

SETTING UP REMOTE UPDATES

Before activating the Remote Updates feature, check to see if calls between systems are toll calls. Also, check the number of subscribers that already exist (traffic : feature : day form). If there are much more than 100 local subscribers, the customer may want to wait for a low traf???c period and/or discount calling time before updates are activated.

Step 1: Activating the Remote Updates Feature

Perform the following steps to activate remote updates. To start with, activate remote updates only between the local AUDIX machine and one remote machine.

5.For R1V3 and R1V4 systems only: Go to the maintenance : audits : fp form and run a network data audit. (This step is not necessary for R1V5 and later systems.)

6.Repeat steps 1 through 5 at the remote system you selected in step 4. Note that the ??????remote?????? system becomes the ??????local?????? system once you log in to it.

Step 2: Testing the Remote Updates Feature

Demand Update Procedure

This procedure will cause a full update from the speci???ed system only.

2.Go to the maintenance : network form and perform a connection test to the system speci???ed in step 1. If this is the ???rst remote update from this system, the connect test could take a long time if there are a large number of subscriber records to be sent.

3.Once the connect test has completed, go to Log In to the Remote Adjunct.

_______________________________________________________________________________________

_______________________________________________________________________________________

Log In to the Remote Adjunct

1.After the automatic or demand update has completed, log in to the remote system and check the list : extension : remote form to see if the subscribers from the local system are now identi???ed by the remote system.

NOTE

You can also check the number of remote and non-administered remote subscribers shown on the traffic : feature : day form. The total of these two ???elds should equal the number of local subscribers shown on this same form at the other AUDIX system.

Check the type ???eld. If any of the subscribers are type v (veri???ed) or are type u (unknown), there may be a minor problem. Most likely the subscriber(s) extension and/or name is duplicated somewhere in the network. Check the following:

a.The subscriber???s extension must be within the address range of their local AUDIX system.

b.Go to the subscriber : remote form, enter the subscriber name or extension/machine

name, and press ENTER . See if more than one machine name is listed. If so, the subscriber cannot be pinpointed to a single AUDIX system. Check for the appearance of the extension at multiple systems. Also, see if the subscriber???s alphanumeric name on the subscriber : local form matches another subscriber???s name. Keep in mind that the alphanumeric pattern is converted to a touch-tone key pattern. For example, ???Smith, Randy??? (7-6-4-8-4, 7-2-6-3-9) and ???Smith, Sandy??? appear the same to the AUDIX system.

c.At the remote AUDIX system, check the administrator???s log to see if the subscriber has a ??????name not recorded?????? entry. If so, record the name. The update facility, at the scheduled interval, will then transmit the change to the other AUDIX systems and will change the subscriber status to administered .

d.At the remote AUDIX system, see if the subscriber has a valid profile (subscriber : local).

e.See if the number of subscribers being added to the system (both local and remote) exceeds the limit assigned on the system : limits form.

2.Repeat step 2 at the local system to see that the subscribers at the remote system are now identi???ed at the local system.

Step 3: Performing Voice Mail Test

1.At the Local Switch, create a message and manually address it to remote subscribers as follows:

a.Log in to the AUDIX system and create a message such as ??????I am testing manual addressing to remote subscribers. Please call me to verify that you have received the message.?????? The message header will tell them who to call.

b.When requested to enter an extension, enter a remote subscriber address as speci???ed on the system : translation : machine : audix/amis/call delivery form, followed by #. Enter one remote subscriber from each remote switch.

c. When ???nished addressing, press * * # for immediate delivery.

14-28 AUDIX Network Testing

________________________________________________________________________________________________

________________________________________________________________________________________________

d.From the main activity menu, press option 4 to check the status of the message delivery.

???At this point, the status will be ??????REMOTE???UNDELIVERED.??????

???After the message has been delivered to the remote AUDIX system, the status will be ??????DELIVERED.??????

???After the remote subscriber has heard the message, the status will be ??????DELIVERED??? ACCESSED.??????

2.At the remote switch, have the remote subscribers verify the following:

a.Their MESSAGE lamp is lit.

b.When they log in to the AUDIX system, the message header includes the AUDIX machine name (if assigned) and the subscriber ID.

3.At the Local Switch, repeat steps 1 and 2 only this time use a mailing list as follows:

a.Log in to the AUDIX system and create a mailing list. Include a subscriber from each AUDIX system.

b.Create a message and address it to the mailing list. The message should include something like ??????I am testing list addressing to remote subscribers. Please call me to verify that you have received the message.??????

c. When ???nished, press * * # for immediate delivery.

d.Press option 4 to check the status of the message delivery.

e.Have the remote subscribers check for new messages.

4.Repeat Steps 1, 2, and 3 at each of the AUDIX systems in the network.

Step 4: Activating Remote Updates for Additional AUDIX Systems

1.If everything went okay in the previous procedures, add a third system to the remote updates facility. You will then have three machine pro???les on three different systems with the Remote Updates feature active.

2.The next scheduled transmission interval at each AUDIX system will cause an update at the other two AUDIX systems. If done during out-of-hours, you can run a demand update using the system : translation : remote update form.

3.Check each system for the appearance of two sets of remote subscribers.

4.Run test calls to/from the newly added system.

5.If everything went okay, add additional systems one at a time.

_______________________________________________________________________________________

_______________________________________________________________________________________

CHECKING ADMINISTRATION LOG ENTRIES

The system administrator???s log can be found on the system : log form. The following entries may appear in this log to help solve network connect failures. There are other entries not shown here that report other areas of concern such as a subscriber that has no name recorded.

???One of these entries may occur when the local system rejects an incoming network call from another system (TN539 or TN539B ACCE only):

?????????Rejected login from remote machine machine name - invalid password??????

?????????Rejected login from remote machine machine name - unknown machine name??????

?????????Rejected login from remote machine machine name?????? (This entry means the call was rejected for some other reason.)

???One of these entries may occur when the local system has an outgoing network call to another system rejected (TN539 or TN539B ACCE only):

?????????Connect to machine machine name aborted - invalid machine name??????

?????????Connect to machine machine name aborted - invalid password??????

?????????Connect to machine machine name aborted - permission denied??????

?????????Connect failure to machine machine name?????? (see NOTE)

(This entry means that there was a problem at the switch: no dial tone, no ringing, busy, dial denied, try again, no carrier, no answer, answered - no response, no resources, protocol handshake failure, premature hang up, or some other reason.)

?????????Continuing connect failure to machine machine name?????? (see NOTE)

???One of these entries may occur when the local system has an outgoing network call to another system rejected (TN366 or TN366B only):

?????????Machine machine name rejected login??????

?????????Connect failure to machine machine name?????? (see NOTE)

?????????Continuing connect failure to machine machine name?????? (see NOTE)

NOTE

The called system will reject a network call if it is very low on voice message space. Local subscribers are given preference over incoming networked messages if disk space is low.

14-30 AUDIX Network Testing

________________________________________________________________________________________________

________________________________________________________________________________________________

TROUBLESHOOTING THE NETWORK

These ???owcharts should help you to troubleshoot the network when you get a ??????failed?????? result for one of the tests. The system : log form might also help with troubleshooting the network. A list of network- related entries in this log are provided in the previous section, Administration Log Entries for Networking. Test procedures can also be found under Testing the Initial Setup of the Network.

Figure 14-19. Checking the ACC(E) Board Status

14-32 AUDIX Network Testing

________________________________________________________________________________________________

________________________________________________________________________________________________

AUDIX CHANNEL STATUS (SEE FIGURE 14-21 ALSO)

Figure 14-20. Checking the ACC(E) Channel Status

_______________________________________________________________________________________

_______________________________________________________________________________________

AUDIX CHANNEL STATUS (SEE ALSO FIGURE 14-20)

RUN CHANNEL INTERNAL

LOOP-AROUND TEST (TEST 2)

MAINT : NET FORM

NOTE:

For AUDIX R1V3 or later,

channels 2 and 4 on Generic 1, Generic 3, or System 75 will always be DOWN. Channels 1 and 3 on a MERLIN II will always be DOWN.

Figure 14-21. Checking the ACC(E) Channel Status

14-34 AUDIX Network Testing

Figure 14-22. Checking the AUDIX Listen Status

Figure 14-23. Local Connection Test

14-36 AUDIX Network Testing

Figure 14-24. Local Connection Failure

Figure 14-25. Near End Connection Test and Failure

14-38 AUDIX Network Testing

________________________________________________________________________________________________

________________________________________________________________________________________________

Figure 14-26. Remote Connection Test

_______________________________________________________________________________________

_______________________________________________________________________________________

REMOTE CONNECTION FAILURE

FAILED/BUSY/

NO ANSWER

REMOTE

TRANSLATIONS

REJECT

CHECK REMOTE ID

AND PASSWORD

NO

GO TO REMOTE

NO

OK?

YES

MORE

CONNECTION TEST

(SEE FIGURE 14-26)

NO

CORRECT

*NOTE:

"N" depends on how busy your network is and how much time you can devote to this test.

THAN ??????N??????

TIMES?*

YES

NO OTHER

REMOTES

FAIL?

FACILITIES

TO THE REMOTE

OK?

YES

ON REMOTE

CHECK NEAR END

CONNECT FAILURE

(SEE FIG 14-25)

YES

Figure 14-27. Remote Connection Failure

14-40 AUDIX Network Testing

________________________________________________________________________________________________

________________________________________________________________________________________________

A. Network Considerations

_______________________________________________________________________________________

_______________________________________________________________________________________

This appendix is targeted for the Business Communications Systems Design Center (BCSDC). Appendix B, Sales Engineering Notes, contains the information that must be completed by the account team and sent to the BCSDC. Every AUDIX Networking installation must be engineered by the BCSDC.

NOTE

The information in this appendix may also be useful to the AUDIX Networking coordinator. The worksheet provided in this appendix should help the coordinator with equipment assignments and extension numbers.

BCSDC CONSIDERATIONS

The BCSDC should consider the following:

???AUDIX and Switch Equipment: See Chapters 1 through 7 for AUDIX system and switch requirements for each particular setup.

???Disk Drive Capacities: When an AUDIX system is networked with another AUDIX system, additional demands may be placed on the storage devices. Each AUDIX system is not only asked to store the names, pro???les, and messages of its local subscribers, but also the names, pro???les, and messages from remote subscribers.

Also, whenever a message is addressed to a remote subscriber, the message is placed in a queue until it can be sent to the remote machine. If the transmission interval is set to deliver remote messages only once or twice a day, the queue area of a particular machine may be asked to store up to 150 messages. Once this limit is reached, a connection to that machine is attempted in order to transmit the messages in queue.

???Trunking: AUDIX R1V6 or later software can support up to six network calls at one time (provided the system has a TN539 vintage 7 or a TN539B ACCE). However, an AUDIX R1V6 or later system connected to a System 75, System 75 XE, DEFINITY Generic 1 or Generic 3, or MERLIN II network can only support four simultaneous calls (two DCP and two RS-232) if the AUDIX system has a TN539 vintage 7 or TN539B with six ports.

AUDIX R1V5 systems can support four simultaneous calls no matter what switch is used, provided the system has the TN539 or TN539B with six ports (with MERLIN II networking this is assuming two RS-232 ports and two DCP ports).

With that in mind, new trunk circuits may or may not be required between switches in the network. AUDIX system traf???c may be able to share existing trunk circuits with other types of inter-node traf???c. AUDIX network traf???c is determined by the following:

???The con???guration of the network (see Figure A-1, Trunking Requirements in an AUDIX Network).

???Does the customer intend on using AUDIX system remote updates feature? If so, and this is generally the case, only a slight additional load is placed on the networking links once the initial exchange of subscriber data is made.

A-1

A-2 Network Considerations

________________________________________________________________________________________________

________________________________________________________________________________________________

???What networking transmission interval is selected (that is, the amount of time between scheduled calls to other systems for passing messages). Does the customer want several short calls spread out during the day or one or two longer calls made during off-hours.

???The amount of voice mail typically addressed to remote subscribers.

???The typical length of these remotely addressed messages.

???Administration: Each AUDIX system and each switch in the network requires administration. Once you have determined how the network should be con???gured, give the information to the coordinator (appointed by the customer and/or AT&T representative) who will make sure each step of the order is completed successfully. This will make troubleshooting of any problems simpler. The steps are:

1.Install, assign, and test the switch for any newly required trunk facilities. This may include modem pooling. Facilities administration may cause service interruptions. For example, if the Alternate Voice/Data (AV/D) bit needs to be set for a Data Services 1 (DS1) trunk group, all trunks must be removed from the group, the group deleted, and everything added back (with AV/D now activated).

2.Install, assign, and test the AUDIX system(s) for local service. This usually requires data link administration which may cause service interruption of other features such as Call Management System (CMS), Distributed Communications Service (DCS), and Message Center. If the AUDIX Communications Controller (ACC) board is already installed, busy out its channels so the system does not acknowledge them until the network is installed. If the ACC is not installed, leave it out until after the AUDIX network is installed.

The network channels must be busied out after any reboot.

NOTE

3.Assign the AUDIX systems for networking service one at a time.

???Communities of interest: Whenever possible, it is recommended that an entire community of interest be administered on a single AUDIX system. Communities of interest consist of subscribers who will exchange messages frequently (for instance people in the same department or working on the same project).

This arrangement is not required, but by keeping all members of a community of interest on the same machine, remote message traf???c could be reduced. Also, remote message throughput could be increased and remote message delivery times could be decreased.

_______________________________________________________________________________________

_______________________________________________________________________________________

AUDIX

E

AT&T

SWITCH

Figure A-1. Trunking Requirements in an AUDIX Network

A-4 Network Considerations

________________________________________________________________________________________________

________________________________________________________________________________________________

AUDIX NETWORK PLANNING WORKSHEET

Network Coordinator: Fill out one of the following worksheets for each AUDIX system in the network. Then give the set of worksheets to the account team or the technician to be used to set up and administer the AUDIX network correctly. This section provides an explanation of each ???eld.

NOTE: Keep this worksheet as a master copy. Make copies for each AUDIX system.

_______________________________________________________________________________________

_______________________________________________________________________________________

AUDIX NETWORK PLANNING WORKSHEET

Class of Service for Networking ports: _______ (Use a separate class of service with only touch tone and data privacy on it.)

_EXTENSIONS:

Type of Connectivity and quantity of DCP extension numbers, if applicable, will depend upon the design. At least one of the extension numbers must be a DID. Please identify which one is the DID number.

DCP Extension Numbers:___________ RS232 Connectivity Extension Numbers:___________

______________________

___________ RS232 (Converted to DCP Connectivity) Extension Numbers: ___________

______________________

System 75/G1 Extension Number of Hunt Group(s), if applicable _______________

_DIAL STRING:

The Dial String to route messages _out of this Audix may need to incorporate various switch routing options. Please identify which switch option this design will implement and the trunk or feature access code being used to accomplish this. (Mark to the left of the category with an "X".)

____DCS; Main/Satellite; Multi-digit Steering, etc. (Incoming extension numbers will be utilized)

For those routing options which utilize a feature access code or only an extension number, please identify the trunk group number and trunk access code of the facility providing the transmission path: TG___________TAC___________

Switchroom Telephone Number: _______________ AUDIX Remote Maintenance Number: _______________

(Preferably through INADS)

Figure A-2. AUDIX Networking Worksheet

A-6 Network Considerations

________________________________________________________________________________________________

________________________________________________________________________________________________

NOTE

If one AUDIX system is directly connected to another through a null-modem cable, no switch extension numbers are necessary.

_______________________________________________________________________________________

_______________________________________________________________________________________

DIAL PLAN: DCS7000-7999

NODE 3

Figure A-3. Address Ranges When Dealing with a DCS Environment

Legend:

??????Dial Plan?????? indicates the extensions in use at the switch. These are both AUDIX subscriber extensions and non-subscriber extensions.

??????Address Ranges?????? indicates the extensions assigned on the system : translation :

machine : audix/amis/call delivery form for the local system.

The purpose of Figure A-3 is to show that the address ranges assigned at AUDIX system 3 should include the dial plan of the entire DCS environment (Nodes 1 through 3), even though AUDIX system 3 serves only Node 1. The reason for this is that a caller at Switch 2, after unsuccessfully reaching a ??????live?????? person at Switch 3, cannot transfer out of the AUDIX system to a person at Node 2 or Node 3 unless the extensions at those nodes appear in the address range(s) along with Node 1???s.

Figure A-3 also shows how multiple ranges and duplicated ranges are used as opposed to using 0000 ??? 9999 at all systems. Using 0000 ??? 9999 would require memory allocation for extensions that do not exist.

A-8 Network Considerations

________________________________________________________________________________________________

________________________________________________________________________________________________

B. Sales Engineering Notes

_______________________________________________________________________________________

_______________________________________________________________________________________

This appendix contains information intended to assist the AT&T sales engineer. The account team should provide any information requested in this appendix to the BCSDC.

BASIC AUDIX AND MISCELLANEOUS AUDIX FEATURES

There is no formal engineering responsibility for basic and miscellaneous AUDIX features. Basic designs for new AUDIX systems, whether stand-alone or integrated with a compatible switch, should be completed at the branch of???ce. This includes sizing of the voice ports and disk space when associated with normal AUDIX operation.

DCS NETWORKS AND AUDIX

If an AUDIX system that uses Mode 3 networking is to be added or installed as part of a Digital Communications System (DCS) network, the BCSDC must be contacted in order to account for the increased traf???c the AUDIX system will create on the tie-trunks among the DCS switch nodes (AUDIX voice calls use the DCS network tie-trunk facilities).

ENGINEERING WORKSHEETS

When a customer is implementing an AUDIX network, the branch must submit an E1154 form and Design Implementation Guide (DIG) forms to the the Business Communications Systems Design Center (BCSDC) before any network engineering will be completed. The branch of???ce should also order a Design Implementation Guide from the BCSDC. To order this document, contact the Design Center Control Desk at (303) 850-8884.

The BCSDC will provide the branch of???ce with worksheets that the branch must complete if a customer has ordered DCS AUDIX, AUDIX Networking, and/or DC AUDIX. The BCSDC is responsible for the power equipment for DC AUDIX.

QUALITY PROTECTION PLAN CHANGE NOTICE (QPPCN)

Any upgraded equipment may be ordered by using a Price Element Code (PEC) or, in some cases, by a QPPCN through the QPPCN Coordinator. Marketing should verify that QPPCNs are kept up-to-date and, with each addition, make sure that any speci???c QPPCNs which apply to that addition have been completed.

B-1

B-2 Sales Engineering Notes

________________________________________________________________________________________________

________________________________________________________________________________________________

UPGRADES, SOFTWARE, AND VINTAGES

It is a Marketing responsibility to verify that correct software exists in both the Private Branch Exchange (PBX) and the AUDIX system and that correct vintages of circuit packs exist in the AUDIX system to accommodate any added features. For example, a Distributed Communications System (DCS) environment with more than ???ve PBXs in the cluster will require checking if the TN533 SCPI is the correct vintage. Use the maintenance : system : vintage form documented in the appropriate AUDIX forms reference manual to determine required minimum vintages.

C. AMIS Analog Networking

_______________________________________________________________________________________

_______________________________________________________________________________________

The AMIS Analog Networking feature is an alternative to digital networking for exchanging messages between voice mail systems. Customers using the AMIS Analog Networking feature can exchange voice mail messages with any other voice mail system, anywhere in the world, provided both systems have AMIS analog capabilities. (Messages can even be exchanged with voice mail systems made by vendors other than AT&T.) The system administrator can administer a range of remote systems that can be addressed via casual addressing (known as two-step addressing); individual remote voice mail systems do not need to be administered. However, the system administrator can also choose to pre-administer any speci???c remote voice mail systems with which their AMIS analog traf???c is heavy for one-step addressing (this simpli???es the addressing procedure).

If subscribers are to receive AMIS analog messages, the system administrator must have administered the local AUDIX to accept incoming AMIS messages. The body of an AMIS analog message is the same as any other voice mail message, but the header information may be different. For messages from remote systems administered for two-step addressing, the header includes the telephone number of the voice mail system and the mailbox ID from which the message was sent.

Two types of remote AMIS connections can be de???ned:

???amisac ??? (AMIS casual, referred to as AMIS two-step addressing) In most cases to address AMIS analog messages via two-step addressing, users must know the AMIS pre???x (if one is de???ned), the full telephone number (area code and country code may be necessary) of the receiving voice mail system, and the mailbox ID of the user who is to receive the message.

???amisap ??? (AMIS pre-administered, referred to as AMIS one-step addressing) Subscribers can address AMIS analog messages to systems administered for one-step addressing in exactly the same way they do to a remote system networked in any other manner. When a remote system is administered for one- step addressing, remote subscribers can be administered on the local system. These administered remote subscribers can be addressed by name as well as by extension.

See AUDIX Administration (585-305-501) for information on administering the AMIS Analog Networking feature. See AUDIX Feature Descriptions (585-305-203) for an overview of the AMIS Analog Networking feature.

C-1

C-2 AMIS Analog Networking

________________________________________________________________________________________________

________________________________________________________________________________________________

Abbreviations

_______________________________________________________________________________________

_______________________________________________________________________________________

AB-1

AB-2 Abbreviations

________________________________________________________________________________________________

________________________________________________________________________________________________

Abbreviations AB-3

_______________________________________________________________________________________

_______________________________________________________________________________________

AB-4 Abbreviations

________________________________________________________________________________________________

________________________________________________________________________________________________

Abbreviations AB-5

_______________________________________________________________________________________

_______________________________________________________________________________________

AB-6 Abbreviations

________________________________________________________________________________________________

________________________________________________________________________________________________

Glossary

_______________________________________________________________________________________

_______________________________________________________________________________________

GL-1

GL-2 Glossary

________________________________________________________________________________________________

________________________________________________________________________________________________

Glossary GL-3

_______________________________________________________________________________________

_______________________________________________________________________________________

GL-4 Glossary

________________________________________________________________________________________________

________________________________________________________________________________________________

Glossary GL-5

_______________________________________________________________________________________

_______________________________________________________________________________________

GL-6 Glossary

________________________________________________________________________________________________

________________________________________________________________________________________________

Glossary GL-7

_______________________________________________________________________________________

_______________________________________________________________________________________

GL-8 Glossary

________________________________________________________________________________________________

________________________________________________________________________________________________

Glossary GL-9

_______________________________________________________________________________________

_______________________________________________________________________________________

GL-10 Glossary

________________________________________________________________________________________________

________________________________________________________________________________________________

? on a display terminal to show the In AUDIX, press * H to get a list

Glossary GL-11

_______________________________________________________________________________________

_______________________________________________________________________________________

GL-12 Glossary

________________________________________________________________________________________________

________________________________________________________________________________________________

Glossary GL-13

_______________________________________________________________________________________

_______________________________________________________________________________________

GL-14 Glossary

________________________________________________________________________________________________

________________________________________________________________________________________________

Glossary GL-15

_______________________________________________________________________________________

_______________________________________________________________________________________

GL-16 Glossary

________________________________________________________________________________________________

________________________________________________________________________________________________

Glossary GL-17

_______________________________________________________________________________________

_______________________________________________________________________________________

GL-18 Glossary

________________________________________________________________________________________________

________________________________________________________________________________________________

Glossary GL-19

_______________________________________________________________________________________

_______________________________________________________________________________________

GL-20 Glossary

________________________________________________________________________________________________

________________________________________________________________________________________________

Glossary GL-21

_______________________________________________________________________________________

_______________________________________________________________________________________

GL-22 Glossary

________________________________________________________________________________________________

________________________________________________________________________________________________

Index

_______________________________________________________________________________________

_______________________________________________________________________________________

IN-1

IN-2 Index

________________________________________________________________________________________________

________________________________________________________________________________________________

analog interface

to analog side of modem pool 5-7 to interlocation facilities 5-7

analog network requirements 11-1 async/sync assignment 13-19 AUDIX networking channels

DCP interface 5-6 AUDIX requirements

DCP mode 1 4-5 DCP mode 2 5-5 DCP mode 3 6-2 dedicated RS-232 2-4

switched RS-232 3-4, 3-8 AUDIX system

administration 1-11, 13-1, A-2 ports administration 13-18 software 1-4, 1-11, B-2 upgrades B-2

B

BCSDC

con???guring 56 Kbps with Generic 2 4-4, 4-7, 10-4

con???guring 5ESS 6-7 con???guring 64 Kbps network 6-1 con???guring ISDN 4-6, 6-5 con???guring mixed networks 7-1 con???guring modem pools 5-1 con???guring RS-232 2-1, 3-1 designing hunting 9-5, 9-7

designing trunk requirements 10-1, B-1 determining data rates 13-21 engineering A-1, B-1

planning A-1 responsibilities A-1

break character 13-7, 13-13 breakout box 11-18 bridging adapter 11-12

C

cabling

common to most con???gurations 1-7 H600-330, Group 1 cable 1-7 H600-331, Group 1 cable 1-9 H600-331, Group 2 cable 1-8 multi-mount modem pool setups 5-11

RS-232 8-1, 8-4

cabling???Contd

stand-alone modem pool 11-18 calculating ???lesystem sizes 13-22 carriage return 13-7, 13-13 channel 13-6, 13-12

circuit packs

AUDIX Large 1-6

AUDIX one- and two-cabinet 1-6 requirements 1-6

colocated requirements 6-4 complete updates 13-2 connection types 13-12 connector panel

AUDIX Large 1-7

AUDIX one- or two-cabinet 1-7

D

data modules

used in modem pool 5-8 data rates 13-5, 13-21

DCP mode 1 4-7 DCP mode 2 5-11 DCP mode 3 6-6 dedicated RS-232 2-5

switched RS-232 3-6, 3-8 Dataphone digital service 4-2

DCP

administration 9-5

and RS-232 in separate locations 7-2

and RS-232 in the same AUDIX system 7-1 cabling 9-1, 9-2

convert RS-232 channel to mode 2 8-8 interface for AUDIX network channels 5-6 interface for digital side of modem pool 5-7

DCP Mode 1 administration 10-1 cabling 10-1

DCP Mode 2 administration 11-20 cabling 11-1

DCP Mode 3 administration 12-1 cabling 12-1

colocated requirements 6-4 interlocation requirements 6-5

DCP ports

administration 9-5, 9-6 switch requirements 9-1

Index IN-3

_______________________________________________________________________________________

_______________________________________________________________________________________

IN-4 Index

________________________________________________________________________________________________

________________________________________________________________________________________________

mode 3???Contd

DCS network engineering B-1 modem pooling 5-2

analog interface to analog side of modem pool

5-7

analog interface to interlocation facilities 5-7 cabling 5-11

data modules 5-8

DCP interface for digital side 5-7 D-lead 11-1

installing equipment 11-1

installing stand-alone modem pools 11-14 modems 5-8

rack-mount equipment 5-11 stand-alone 11-1, 11-18

standalone modem pool combinations 5-10 switch administration 11-20

test the facilities 11-23 modems

con???rm ID/versions 8-6 dip switch settings 8-7

initialization strings 11-17, 13-20 loop-around test 14-25

mixing types and modes 8-7

rack-mounted modem pool combinations 5-9 set options using RS-232 breakout box 11-18 Telebit T1000 13-13, 13-21

used in modem pool 5-8 move subscribers 13-25

MPDM

upgrade to M1* 10-8 MPDM/M1*

init string 13-20

loopback testing 10-8, 10-10 option settings 8-8

setup 10-8

MTDM

data module 5-8 D-Kit 5-8

installing in modem pool 11-1 TRIC 4 chips 11-4

multi-stage dialing 1-11, 13-7, 13-13

N

network connection turnaround 13-2 network connection type 13-5 network data audit 13-10, 13-16 networking

networking???Contd common cabling 1-7

mixed RS-232 and DCP networks 7-1 software requirements 1-4, 1-11

tests 14-1 networks

56 Kbps networking 4-1

64 Kbps networking 6-1

dedicated RS-232 con???gurations 2-1 enhancements in AUDIX releases 1-11 implementation 1-3

modem pooling 5-1 planning 1-3

switched RS-232 con???gurations 3-1 types of interfaces 1-1

non-DCP switch applications 9-2

O

option settings

2296A 11-9, 11-16

7400A 8-8

7400A DSU 11-11, 11-19

7400B 8-8 DM424 11-17 MPDM/M1* 8-8 MTDM 11-4

Paradyne 3820 11-17

using RS-232 breakout box 11-18

P

Paradyne modems 11-14 partial updates 13-1 passwords 13-5, A-4 ports

administering on AUDIX 13-18

Q

QPPCNs B-1

R

R1V5 enhancements 1-11 R1V6 enhancements 1-12 R1V7 enhancements 1-12 recording machine names 13-17

Index IN-5

_______________________________________________________________________________________

_______________________________________________________________________________________

remote networking

AAR/ARS administration 9-6, 12-2, 12-3 connection tests 14-4

de???ned 1-3

remote subscribers, calculate ???lesystem space

13-22

remote updates 13-1, 13-8 activating 14-26, 14-28 setting up 14-26 testing 14-26

RS-232

and DCP in separate locations 7-2

and DCP in the same AUDIX system 7-1 breakout box 11-18

cabling 8-1, 8-4

DCP mode 2 conversion 8-8 dedicated 1-1, 2-1, 8-1, 13-19 port administration 13-18 requirements 1-11, 8-1

standalone modem pool combinations 5-10 switched 1-1, 3-1, 3-2, 8-4, 13-19

testing remote connections 14-8, 14-11, 14-13 using data modules for DCP 3-7

S

sales engineering notes B-1 SN253C tone pack administration

Generic 2 9-9

System 85 9-8

SN255(B) tone detector administration Generic 2 9-9

System 85 9-8

Static 56 Kbps networking 4-4, 4-6 subscribers

moving within network 13-25 switch administration 10-1

AUDIX DCP ports 9-5, 9-6, 9-9 DCP 9-5

mode 2 11-20 mode 3 12-1

switch component installation 10-1, 12-1 switch requirements

DCP mode 1 4-6 DCP mode 2 5-5 DCP mode 3 6-4 dedicated RS-232 2-5

switched RS-232 3-4, 3-8 switched RS-232

switched RS-232???Contd

con???rm modem ID/versions 8-6 Hayes??-compatible modems 3-4 rack-mounted modem pool combinations 5-9

sync/async assignment 13-19 system : limits form 13-23

system : translation : machine : audix/amis/call delivery form 13-4, 13-10

system : translation : network port form 13-18 System 75

56 Kbps administration 10-2 ACC(E) DCP administration 9-5 DCP mode 3 administration 12-1 modem pool administration 11-20

System 85

56 Kbps administration 10-3 ACC(E) DCP administration 9-6 DCP mode 3 administration 12-2 modem pool administration 11-21 modem pool testing 11-23

system pro???les, see machine pro???les

T

T1 Carrier 6-5

Telebit T1000

dial string 13-13 init string 13-21

switch administration 13-21 testing

56/64 Kbps loopback tests 14-23 local connection 14-19 loop-around tests 14-15, 14-25 near-end connection 14-15 network connections 14-4 troubleshooting the network 14-30 voice mail 14-27

TN472C vintage 2 1-6 TN506B 1-6

TN508 vintage 4 1-6 TN509C 1-6

tone detector administration 9-8, 9-9 transmission schedule 13-8, 13-14 TRIC 4 chips 11-4

troubleshooting ???owcharts 14-30 trunking A-1

IN-6 Index

________________________________________________________________________________________________

________________________________________________________________________________________________

U

UN160B 1-6 UN160B vintage 2 1-6 updates

complete 13-2

demand procedure 14-26 partial 13-1

remote 13-1, 14-26

V

voice ID 13-5, 13-11 voice name 13-5

W

worksheet administrator 13-27

forms for BCSDC B-1 planning A-4